- Preface
- Chapter 1, Shelf Assembly Hardware
- Chapter 2, Common Control Cards
- Chapter 3, Optical Service Channel Cards
- Chapter 4, Optical Amplifier Cards
- Chapter 5, Multiplexer and Demultiplexer Cards
- Chapter 6, Optical Add/Drop Cards
- Chapter 7, Reconfigurable Optical Add/Drop Cards
- Chapter 8, Transponder and Muxponder Cards
- Chapter 9, Node Reference
- Chapter 10, Network Reference
- Chapter 11, Optical Channel Circuits and Virtual Patchcords Reference
- Chapter 12, Cisco Transport Controller Operation
- Chapter 13, Security Reference
- Chapter 14, Timing Reference
- Chapter 15, Manage Network Connectivity
- Chapter 16, Alarm and TCA Monitoring and Management
- Chapter 17, Performance Monitoring
- Chapter 18, SNMP
- Appendix A, Hardware Specifications
- Appendix B, Administrative and Service States
- Appendix C, Network Element Defaults
Network Element Defaults
Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration. Rather, these terms, as well as "Path Protected Mesh Network" and "PPMN," refer generally to Cisco's path protection feature, which may be used in any topological network configuration. Cisco does not recommend using its path protection feature in any particular topological network configuration.
This appendix describes the factory-configured (default) network element (NE) settings for the Cisco ONS 15454. It includes descriptions of card, node, and Cisco Transport Controller (CTC) default settings. To import, export, or edit the settings, see the "Maintain the Node" chapter in the Cisco ONS 15454 DWDM Procedure Guide. Cards supported by this platform that are not listed in this appendix are not supported by user-configurable NE defaults settings.
Note Unless otherwise specified, in this appendix "ONS 15454" refers to both ANSI (ONS 15454 SONET) and ETSI (ONS 15454 SDH) shelf assemblies.
C.1 Network Element Defaults Description
The NE defaults are preinstalled on each Cisco ONS 15454 TCC2 and TCC2P card. Cisco also ships a file named 15454-defaults.txt (ANSI shelves) or 15454SDH-defaults.txt (ETSI shelves) on the CTC software CD in case you want to import the defaults onto existing TCC2/TCC2P cards. The NE defaults include card-level, CTC, and node-level defaults.
Manual card provisioning overrides default settings. Manual changes are those made using the "Provision Transponder and Muxponder Cards" chapter or the "Change DWDM Card Settings" chapter in the Cisco ONS 15454 DWDM Procedure Guide. If you use the CTC Defaults editor (on the node view Provisioning > Defaults tabs) or import a new defaults file, any changes to card or port settings that result only affect cards that are installed or preprovisioned after the defaults have changed.
Changes made manually to most node-level default settings override the current settings, whether default or provisioned. If you change node-level default settings, either by using the Defaults editor or by importing a new defaults file, the new defaults reprovision the node immediately for all settings except those relating to protection (1+1 bidirectional switching, 1+1 reversion time, 1+1 revertive, Bidirectional Line Switched Ring [BLSR] or multiplex section-shared protection ring [MS-SPRing] reversion time, BLSR/MS-SPRing ring revertive, BLSR/MS-SPRing span reversion time, BLSR/MS-SPRing span revertive, y cable revertive or reversion time, splitter revertive or reversion time). Settings relating to protection apply to subsequent provisioning.
Note Changing some node-level provisioning through NE defaults can cause CTC disconnection or a reboot of the node in order for the provisioning to take effect. Before you change a default, check in the Side Effects column of the Defaults editor (right-click a column header and select Show Column > Side Effects) and be prepared for the occurrence of any side effects listed for that default.
C.2 ANSI Platform Defaults
The following sections give the NE defaults for the ONS 15454 ANSI platform. To see defaults for the ONS 15454 ETSI platform, see the "ETSI Platform Defaults" section.
C.2.1 ANSI Card Defaults
The tables in this section list the default settings for each DWDM, Transponder (TXP), Muxponder (MXP), or Ethernet card. Cisco provides several types of user-configurable defaults for Cisco ONS 15454 DWDM, TXP, MXP, and Ethernet cards. Types of card defaults can be broadly grouped by function, as outlined in the following subsections. For information about individual card settings, refer to the "Provision Transponder and Muxponder Cards" chapter or the "Change DWDM Card Settings" chapter in the Cisco ONS 15454 DWDM Procedure Guide.
Note The tables in this section list the default settings for each DWDM, TXP, and MXP card. For all other cards, including electrical, optical, Ethernet, and Fibre Channel, refer to the Cisco ONS 15454 Reference Manual or the Cisco ONS 15454 SDH Reference Manual.
Note When the card level defaults are changed, the new provisioning done after the defaults have changed is affected. Existing provisioning remains unaffected.
The following types of defaults are defined for DWDM, TXP, MXP, and Ethernet cards.
C.2.1.1 ANSI Configuration Defaults
Most card-level and port-level configuration defaults correspond to settings found in the CTC card-level Provisioning tabs.
Note The full set of Automatic Laser Shutdown (ALS) configuration defaults can be found in the CTC card-level Maintenance > ALS tab for supported cards. ALS defaults are supported for OSCM, OSC-CSM, OPT-BST, OPT-BST-L, ADM-10G, GE_XP, 10GE_XP, TXP, and MXP cards. For information on how ALS card settings achieve network level optical safety, see Chapter 3, "Optical Service Channel Cards," Chapter 4, "Optical Amplifier Cards," or Chapter 8, "Transponder and Muxponder Cards."
Configuration defaults that are reachable from the CTC card-level Provisioning tabs (except as noted) include the following types of options (arranged by CTC subtab):
•Line—(ADM-10G, GE_XP, 10GE_XP, TXP and MXP cards) Line-level configuration settings, including SONET, Wavelength Trunk, Trunk, Client, Distance Extension, and Enhanced FC/FICON ISL settings.
Note Some line configuration tabs, including Client, Distance Extension, and Enhanced FC/FICON ISL settings tabs, only appear in the card-level Provisioning > Line tab after a pluggable port module (PPM) is provisioned to a fibre channel payload type (port rate) for the particular card.
•OTN—(ADM-10G, GE_XP, 10GE_XP, MXP-2.5G-10E, MXP-2_5G-10G, MXP-MR-10DME, TXP-MR-10E, TXP-MR-10G, TXP-MR-2.5G, and TXPP-MR-2.5G cards) Optical transport network (OTN) line configuration settings.
•Card—(See listed settings for applicable cards)
–Card mode—MXPP-MR-2.5G and MXP-MR-2.5G (ESCON, FC_GE, or MIXED), GE_XP (20GE MXP, 10GE MXP, or L2 over DWDM) , and 10GE_XP (10GE TXP or L2 over DWDM)
–Port range-level mode settings—MXP-MR-10DME cards only
–Termination mode—TXP-MR-10E, MXP-2.5G-10E, MXP-2.5G-10G, TXPP_MR_2.5G, TXP_MR_10G, and TXP_MR_2.5G cards
–AIS squelch settings—TXP-MR-10E and MXP-2.5G-10E cards
•ALS (card-level Maintenance > ALS tab)—(OSC-CSM, OSCM, OPT-BST, OPT-BST-L, ADM-10G, GE_XP, 10GE_XP, TXP, and MXP cards) ALS configuration defaults.
Note For further information about supported features on each card, see Chapter 3, "Optical Service Channel Cards," Chapter 4, "Optical Amplifier Cards," or Chapter 8, "Transponder and Muxponder Cards."
C.2.1.2 ANSI Threshold Defaults
Threshold default settings define the default cumulative values (thresholds) beyond which a threshold crossing alert (TCA) will be raised, making it possible to monitor the network and detect errors early.
Card threshold default settings are provided as follows:
•PM thresholds—(OSCM, OSC-CSM, TXP, and MXP cards) Expressed in counts or seconds; includes line and SONET thresholds.
•Optical thresholds—(ADM-10G, GE_XP, 10GE_XP, TXP, and MXP cards) Expressed in percentages or dBm; includes client and trunk optical thresholds.
•OTN FEC thresholds (ADM-10G, GE_XP, 10GE_XP, TXP, and MXP cards)—Expressed in counts; includes enhanced, standard, 1G Ethernet, 1G Fibre channel, 1G FICON, OC-3, OC-12, OC-48, 2G FICON, and 2G Fibre channel thresholds.
•OTN G.709 thresholds (ADM-10G, GE_XP, 10GE_XP, TXP, and MXP cards)—Expressed in counts or seconds; includes ITU-T G.709 PM and SM thresholds.
Threshold defaults are defined for near end and/or far end, at 15-minute and one-day intervals. Thresholds are further broken down by type, such as Multiplex Section, Regeneration Section, VC LO, MS, RS, or Path, for performance monitoring (PM) thresholds, and TCA (warning) or Alarm for physical thresholds. PM threshold types define the layer to which the threshold applies. Physical threshold types define the level of response expected when the threshold is crossed.
Note For full descriptions of the thresholds you can set for each card, see Chapter 17, "Performance Monitoring."
Note When LOS, LOS-P, or LOF alarms occur on transponder and muxponder trunks, ITU-T G.709 SONET/SDH TCAs are suppressed. For details, see Chapter 16, "Alarm and TCA Monitoring and Management."
Note For additional information regarding PM parameter threshold defaults as defined by Telcordia specifications, refer to Telcordia GR-820-CORE and GR-253-CORE.
C.2.1.3 ANSI Defaults by Card
In the tables that follow, card defaults are defined by the default name, its factory-configured value, and the domain of allowable values that you can assign to it.
Note Some default values, such as certain thresholds, are interdependent. Before changing a value, review the domain for that default and any other related defaults for potential dependencies.
C.2.1.3.1 ANSI ADM-10G Card Default Settings
Table C-1 lists the ADM-10G card default settings.
C.2.1.3.2 ANSI MXP_2.5G_10E Card Default Settings
Table C-2 lists the MXP_2.5G_10E card default settings.
C.2.1.3.3 ANSI MXP_2.5G_10G Card Default Settings
Table C-3 lists the MXP_2.5G_10G card default settings.
C.2.1.3.4 ANSI MXP_MR_2.5G Card Default Settings
Table C-4 lists the MXP_MR_2.5G card default settings.
C.2.1.3.5 ANSI MXPP_MR_2.5G Card Default Settings
Table C-5 lists the MXPP_MR_2.5G card default settings.
C.2.1.3.6 ANSI MXP_MR_10DME_C and MXP_MR_10DME_L Card Default Settings
Table C-6 lists the MXP_MR_10DME_C and MXP_MR_10DME_L card default settings.
C.2.1.3.7 ANSI TXP_MR_10E Card Default Settings
Table C-7 lists the TXP_MR_10E card default settings.
C.2.1.3.8 ANSI TXP_MR_10G Card Default Settings
Table C-8 lists the TXP_MR_10G card default settings.
C.2.1.3.9 ANSI TXP_MR_2.5G Card Default Settings
Table C-9 lists the TXP_MR_2.5G card default settings.
C.2.1.3.10 ANSI TXPP_MR_2.5G Card Default Settings
Table C-10 lists the TXPP_MR_2.5G card default settings.
C.2.1.3.11 ANSI GE_XP Card Default Settings
Table C-11 lists the GE_XP card default settings.
C.2.1.3.12 ANSI 10GE_XP Card Default Settings
Table C-12 lists the 10GE_XP card default settings.
C.2.1.3.13 ANSI OSCM Card Default Settings
Table C-13 lists the OSCM card default settings.
C.2.1.3.14 ANSI OSC-CSM Card Default Settings
Table C-14 lists the OSC-CSM card default settings.
C.2.1.3.15 ANSI Amplifier Card Default Settings
Table C-15 lists the OPT-BST, OPT-BST-L, OPT-AMP-C, and OPT-AMP-17-C card default settings.
C.2.2 ANSI Node Default Settings
Table C-16 lists the node-level default settings for the Cisco ONS 15454. Cisco provides the following types of user-configurable defaults for each Cisco ONS 15454 node:
•Circuit settings—Set the administrative state and path protection circuit defaults, and whether to have circuits send a payload defect indication condition (PDIP).
•General settings—Set general node management defaults, including whether to use Daylight Savings Time (DST), whether to insert Alarm Indication Signal VT (AIS-V) in each VT when the carrying STS crosses the signal degrade (SD) path bit error rate (BER) threshold, the IP address of the Network Time Protocol/Simple Network Time Protocol (NTP/SNTP) server to be used, the time zone where the node is located, the SD path BER value, the defaults description, whether to raise a condition on an empty card slot, whether automatic autonomous Transcation Language One (TL1) reporting of PM data is enabled for cross-connect paths on the node, whether or not to allow ports to be disabled when they are providing services (when the default is set to FALSE users must remove or disable the services first, then put the ports out of service), and whether to report loopback conditions on Out-of-Service, Maintenance (OOS-MT) state ports.
•Link Management Protocol settings—Set link management protocol data link type, traffic engineering link, and general settings.
•Power Monitor settings—Set default voltage thresholds for the node.
•Network settings—Set whether to prevent display of node IP addresses in CTC (applicable for all users except Superusers); default gateway node type; whether to raise an alarm when the backplane LAN cable is disconnected; and whether to display the IP address in the LCD in an editable mode (in which you can change the IP address directly from LCD screen), to display the IP address on the LCD as read-only, or to suppress display of the IP on the LCD entirely.
•OSI settings—Set the Open System Interconnection (OSI) main setup, generic routing encapsulation (GRE) tunnel, link access protocol on the D channel (LAP-D), the router subnet, and the TID address resolution protocol (TARP) settings.
•1+1 and Optimized 1+1 protection settings—Set whether or not protected circuits have bidirectional switching, are revertive, and what the reversion time is; set optimized 1+1 detection, recovery, and verify guard timer values.
Note Optimized 1+1 supports three timers that ensure the correct state of the cards at key points in card communication. A verification guard timer is used when a Force is issued, to ensure that the far end has a chance to respond. A detection guard timer is used to ensure the presence of an SF/SD condition before switching away from a card. A recover guard timer ensures the absence of SF/SD prior to switching to a card. You can change the default number of seconds before these timers expire by changing the NE default for the corresponding timer to a value within its domain of allowable values.
•BLSR protection settings—Set whether BLSR-protected circuits are revertive, and what the reversion time is, at both the ring and span levels.
•Y Cable protection settings—Set whether Y-cable protected circuits are revertive, and what the reversion time is.
•Splitter protection settings—Set whether splitter protected circuits are revertive, and what the reversion time is.
•Legal Disclaimer—Set the legal disclaimer that warns users at the login screen about the possible legal or contractual ramifications of accessing equipment, systems, or networks without authorization.
•Security Grant Permissions—Set default user security levels for activating/reverting software, PM data clearing, database restoring, and retrieving audit logs.
•Security DataComm settings—Set default security settings for TCC Ethernet IP address and IP netmask, and CTC backplane IP suppression; set secure mode on and secure mode locked (for TCC2P cards only).
•Security Access settings—Set default security settings for LAN access, shell access, serial craft access, element management system (EMS) access (including Internet Inter-Object Request Broker Protocol [IIOP] listener port number), TL1 access, and Simple Network Management Protocol (SNMP) access.
•Security RADIUS settings—Set default RADIUS server settings for the accounting port number and the authentication port number, and whether to enable the node as a final authenticator.
•Security Policy settings—Set the allowable failed logins before lockout, idle user timeout for each user level, optional lockout duration or manual unlock enabled, password reuse and change frequency policies, number of characters difference that is required between the old and new password, password aging by security level, enforced single concurrent session per user, and option to disable inactive user after a set inactivity period.
•Security Password settings—Set when passwords can be changed, how many characters they must differ by, whether or not password reuse is allowed, and whether a password change is required on first login to a new account; set password aging enforcement and user-level specific aging and warning periods; set how many consecutive identical characters are allowed in a password, maximum password length, minimum password length, minimum number and combination of nonalphabetical characters required, and whether or not to allow a password that is a reversal of the login ID associated with the password.
•BITS Timing settings—Set the AIS threshold, Admin synchronization status messaging (SSM), coding, facility type, framing, state, and line build-out (LBO) settings for building integrated timing supply 1 (BITS-1) and BITS2 timing.
•General Timing settings—Set the mode (External, Line, or Mixed), quality of reserved (RES) timing (the rule that defines the order of clock quality from lowest to highest), revertive, reversion time, and SSM message set for node timing.
Note Any node level defaults changed using the Provisioning > Defaults tab, changes existing node level provisioning. Although this is service affecting, it depends on the type of defaults changed, for example, general, and all timing and security attributes. The "Changing default values for some node level attributes overrides the current provisioning." message is displayed. The Side Effects column of the Defaults editor (right-click a column header and select Show Column > Side Effects) explains the effect of changing the default values. However, when the card level defaults are changed using the Provisioning > Defaults tab, existing card provisioning remains unaffected.
Note For more information about each individual node setting, refer to the "Manage the Node" chapter in the Cisco ONS 15454 DWDM Procedure Guide.
|
|
|
---|---|---|
NODE.circuits.SendPDIP |
TRUE |
TRUE, FALSE |
NODE.circuits.State |
IS,AINS |
IS, OOS,DSBLD, OOS,MT, IS,AINS |
NODE.circuits.upsr.AllowUpsrOverOnePlusOne |
FALSE |
TRUE, FALSE |
NODE.circuits.upsr.ProvisionWorkingGoAndReturnOnPrimaryPath |
TRUE |
TRUE, FALSE |
NODE.circuits.upsr.ReversionTime |
5.0 (minutes) |
0.5, 1.0, 1.5 .. 12.0 |
NODE.circuits.upsr.Revertive |
FALSE |
TRUE, FALSE |
NODE.circuits.upsr.STS_SDBER |
1.00E-06 |
1E-5, 1E-6, 1E-7, 1E-8, 1E-9 |
NODE.circuits.upsr.STS_SFBER |
1.00E-04 |
1E-3, 1E-4, 1E-5 |
NODE.circuits.upsr.SwitchOnPDIP |
FALSE |
TRUE, FALSE |
NODE.circuits.upsr.VT_SDBER |
1.00E-05 |
1E-5, 1E-6, 1E-7, 1E-8 |
NODE.circuits.upsr.VT_SFBER |
1.00E-03 |
1E-3, 1E-4, 1E-5 |
NODE.general.AllowServiceAffectingPortChangeToDisabled |
TRUE |
FALSE, TRUE |
NODE.general.AutoPM |
FALSE |
FALSE, TRUE |
NODE.general.DefaultsDescription |
Factory Defaults |
Free form field |
NODE.general.InsertAISVOnSDP |
FALSE |
TRUE, FALSE |
NODE.general.NtpSntpServer |
0.0.0.0 |
IP Address |
NODE.general.RaiseConditionOnEmptySlot |
FALSE |
TRUE, FALSE |
NODE.general.ReportLoopbackConditionsOnOOS-MTPorts |
FALSE |
FALSE, TRUE |
NODE.general.SDPBER |
1.00E-06 |
1E-5, 1E-6, 1E-7, 1E-8, 1E-9 |
NODE.general.TimeZone |
(GMT-08:00) Pacific Time (US & Canada), Tijuana |
(For applicable time zones, see Table C-17.) |
NODE.general.UseDST |
TRUE |
TRUE, FALSE |
NODE.lmp.controlChannel.AdminState |
OOS,DSBLD |
IS, OOS,DSBLD |
NODE.lmp.controlChannel.HelloDeadInterval |
12000 (ms) |
maximum_of(2000,MinHelloDeadInterval,product_of(HelloInterval,3)), maximum_of(2000,MinHelloDeadInterval,product_of(HelloInterval,3)) + 1, maximum_of(2000,MinHelloDeadInterval,product_of(HelloInterval,3)) + 2 .. minimum_of(20000,MaxHelloDeadInterval) |
NODE.lmp.controlChannel.HelloInterval |
500 (ms) |
maximum_of(300,MinHelloInterval), maximum_of(300,MinHelloInterval) + 1, maximum_of(300,MinHelloInterval) + 2 .. minimum_of(5000,MaxHelloInterval,quotient_of(HelloDeadInterval,3)) |
NODE.lmp.controlChannel.MaxHelloDeadInterval |
20000 (ms) |
maximum_of(2000,HelloDeadInterval,sum_of(MaxHelloInterval,1)), maximum_of(2000,HelloDeadInterval,sum_of(MaxHelloInterval,1)) + 1, maximum_of(2000,HelloDeadInterval,sum_of(MaxHelloInterval,1)) + 2 .. 20000 |
NODE.lmp.controlChannel.MaxHelloInterval |
2000 (ms) |
maximum_of(300,HelloInterval), maximum_of(300,HelloInterval) + 1, maximum_of(300,HelloInterval) + 2 .. minimum_of(5000,difference_of(MaxHelloDeadInterval,1)) |
NODE.lmp.controlChannel.MinHelloDeadInterval |
2000 (ms) |
maximum_of(2000,sum_of(MinHelloInterval,1)), maximum_of(2000,sum_of(MinHelloInterval,1)) + 1, maximum_of(2000,sum_of(MinHelloInterval,1)) + 2 .. minimum_of(20000,HelloDeadInterval) |
NODE.lmp.controlChannel.MinHelloInterval |
300 (ms) |
300, 301, 302 .. minimum_of(5000,HelloInterval,difference_of(MinHelloDeadInterval,1)) |
NODE.lmp.dataLink.Type |
Port |
Port, Component |
NODE.lmp.general.Allowed |
TRUE |
FALSE, TRUE |
NODE.lmp.general.Enabled |
FALSE |
FALSE, TRUE when Allowed TRUE; FALSE when Allowed FALSE |
NODE.lmp.general.LMP-WDM |
TRUE |
FALSE, TRUE |
NODE.lmp.general.Role |
OLS |
PEER, OLS |
NODE.lmp.teLink.AdminState |
OOS,DSBLD |
IS, OOS,DSBLD |
NODE.lmp.teLink.DWDM |
TRUE |
FALSE, TRUE |
NODE.lmp.teLink.MuxCapability |
Lambda Switch |
Packet Switch - Level 1, Packet Switch - Level 2, Packet Switch - Level 3, Packet Switch - Level 4, Layer 2 Switch, TDM Cross-connect, Lambda Switch, Fiber Switch |
NODE.network.general.AlarmMissingBackplaneLAN |
FALSE |
TRUE, FALSE |
NODE.network.general.CtcIpDisplaySuppression |
FALSE |
TRUE, FALSE |
NODE.network.general.GatewaySettings |
None |
LeaveAsIs, None, ENE, GNE, ProxyOnlyNode |
NODE.network.general.LcdSetting |
Allow Configuration |
Allow Configuration, Display Only, Suppress Display |
NODE.osi.greTunnel.OspfCost |
110 |
110 - 65535 |
NODE.osi.greTunnel.SubnetMask |
24 (bits) |
8, 9, 10 .. 32 |
NODE.osi.lapd.Mode |
AITS |
AITS, UITS |
NODE.osi.lapd.MTU |
512 |
512, 513, 514 .. 1500 |
NODE.osi.lapd.Role |
Network |
Network, User |
NODE.osi.lapd.T200 |
200 (ms) |
200, 300, 400 .. 20000 |
NODE.osi.lapd.T203 |
10000 (ms) |
4000, 4100, 4200 .. 120000 |
NODE.osi.mainSetup.L1L2LSPBufferSize |
512 (bytes) |
512 - 1500 |
NODE.osi.mainSetup.L1LSPBufferSize |
512 (bytes) |
512 - 1500 |
NODE.osi.mainSetup.NodeRoutingMode |
Intermediate System Level 1 |
End System, Intermediate System Level 1, Intermediate System Level 1/Level 2 |
NODE.osi.subnet.DISPriority |
63 |
1, 2, 3 .. 127 |
NODE.osi.subnet.ESH |
10 (sec) |
10, 20, 30 .. 1000 |
NODE.osi.subnet.GCCISISCost |
60 |
1, 2, 3 .. 63 |
NODE.osi.subnet.IIH |
3 (sec) |
1, 2, 3 .. 600 |
NODE.osi.subnet.ISH |
10 (sec) |
10, 20, 30 .. 1000 |
NODE.osi.subnet.LANISISCost |
20 |
1, 2, 3 .. 63 |
NODE.osi.subnet.LDCCISISCost |
40 |
1, 2, 3 .. 63 |
NODE.osi.subnet.OSCISISCost |
60 |
1, 2, 3 .. 63 |
NODE.osi.subnet.SDCCISISCost |
60 |
1, 2, 3 .. 63 |
NODE.osi.tarp.L1DataCache |
TRUE |
FALSE, TRUE |
NODE.osi.tarp.L2DataCache |
FALSE |
FALSE, TRUE |
NODE.osi.tarp.LANStormSuppression |
TRUE |
FALSE, TRUE |
NODE.osi.tarp.LDB |
TRUE |
FALSE, TRUE |
NODE.osi.tarp.LDBEntry |
5 (min) |
1 - 10 |
NODE.osi.tarp.LDBFlush |
5 (min) |
0 - 1440 |
NODE.osi.tarp.PDUsL1Propagation |
TRUE |
FALSE, TRUE |
NODE.osi.tarp.PDUsL2Propagation |
TRUE |
FALSE, TRUE |
NODE.osi.tarp.PDUsOrigination |
TRUE |
FALSE, TRUE |
NODE.osi.tarp.T1Timer |
15 (sec) |
0 - 3600 |
NODE.osi.tarp.T2Timer |
25 (sec) |
0 - 3600 |
NODE.osi.tarp.T3Timer |
40 (sec) |
0 - 3600 |
NODE.osi.tarp.T4Timer |
20 (sec) |
0 - 3600 |
NODE.osi.tarp.Type4PDUDelay |
0 (sec) |
0 - 255 |
NODE.powerMonitor.EHIBATVG |
-56.5 (Vdc) |
-54.0, -54.5, -55.0, -55.5, -56.0, -56.5 |
NODE.powerMonitor.ELWBATVG |
-40.5 (Vdc) |
-40.5, -41.0, -41.5, -42.0, -42.5, -43.0, -43.5, -44.0 |
NODE.powerMonitor.HIBATVG |
-54.0 (Vdc) |
-44.0, -44.5, -45.0 .. -56.5 |
NODE.powerMonitor.LWBATVG |
-44.0 (Vdc) |
-40.5, -41.0, -41.5 .. -54.0 |
NODE.protection.1+1.BidirectionalSwitching |
FALSE |
TRUE, FALSE |
NODE.protection.1+1.DetectionGuardTimer |
1 (seconds) |
0, 0.05, 0.1, 0.5, 1, 2, 3, 4, 5 |
NODE.protection.1+1.RecoveryGuardTimer |
1 (seconds) |
0, 0.05, 0.1 .. 10 |
NODE.protection.1+1.ReversionTime |
5.0 (minutes) |
0.5, 1.0, 1.5 .. 12.0 |
NODE.protection.1+1.Revertive |
FALSE |
TRUE, FALSE |
NODE.protection.1+1.VerifyGuardTimer |
0.5 (seconds) |
0.5, 1 |
NODE.protection.blsr.RingReversionTime |
5.0 (minutes) |
0.5, 1.0, 1.5 .. 12.0 |
NODE.protection.blsr.RingRevertive |
TRUE |
TRUE, FALSE |
NODE.protection.blsr.SpanReversionTime |
5.0 (minutes) |
0.5, 1.0, 1.5 .. 12.0 |
NODE.protection.blsr.SpanRevertive |
TRUE |
TRUE, FALSE |
NODE.protection.splitter.ReversionTime |
5.0 (minutes) |
0.5, 1.0, 1.5 .. 12.0 |
NODE.protection.splitter.Revertive |
FALSE |
TRUE, FALSE |
NODE.protection.ycable.ReversionTime |
5.0 (minutes) |
0.5, 1.0, 1.5 .. 12.0 |
NODE.protection.ycable.Revertive |
FALSE |
TRUE, FALSE |
NODE.security.dataComm.CtcBackplaneIpDisplaySuppression |
TRUE |
FALSE, TRUE when isSecureModeSupportedOnControlCard TRUE; (NOT SUPPORTED) when isSecureModeSupportedOnControlCard FALSE |
NODE.security.dataComm.DefaultTCCEthernetIP |
10.0.0.1 |
IP Address |
NODE.security.dataComm.DefaultTCCEthernetIPNetmask |
24 (bits) |
8, 9, 10 .. 32 |
NODE.security.dataComm.isSecureModeSupportedOnControlCard |
TRUE |
FALSE, TRUE |
NODE.security.dataComm.LcdBackplaneIpSetting |
Display Only |
Allow Configuration, Display Only, Suppress Display when isSecureModeSupportedOnControlCard TRUE; (NOT SUPPORTED) when isSecureModeSupportedOnControlCard FALSE |
NODE.security.dataComm.SecureModeLocked |
FALSE |
FALSE, TRUE when isSecureModeSupportedOnControlCard TRUE; (NOT SUPPORTED) when isSecureModeSupportedOnControlCard FALSE |
NODE.security.dataComm.SecureModeOn (May reboot node) |
FALSE |
FALSE, TRUE when isSecureModeSupportedOnControlCard TRUE; (NOT SUPPORTED) when isSecureModeSupportedOnControlCard FALSE |
NODE.security.emsAccess.AccessState |
NonSecure |
NonSecure, Secure |
NODE.security.emsAccess.IIOPListenerPort (May reboot node) |
57790 (port #) |
0 - 65535 |
NODE.security.grantPermission.ActivateRevertSoftware |
Superuser |
Provisioning, Superuser |
NODE.security.grantPermission.PMClearingPrivilege |
Provisioning |
Provisioning, Superuser |
NODE.security.grantPermission.RestoreDB |
Superuser |
Provisioning, Superuser |
NODE.security.grantPermission.RetrieveAuditLog |
Superuser |
Provisioning, Superuser |
NODE.security.idleUserTimeout.Maintenance |
01:00 (hours:mins) |
00:00, 00:01, 00:02 .. 16:39 |
NODE.security.idleUserTimeout.Provisioning |
00:30 (hours:mins) |
00:00, 00:01, 00:02 .. 16:39 |
NODE.security.idleUserTimeout.Retrieve |
00:00 (hours:mins) |
00:00, 00:01, 00:02 .. 16:39 |
NODE.security.idleUserTimeout.Superuser |
00:15 (hours:mins) |
00:00, 00:01, 00:02 .. 16:39 |
NODE.security.lanAccess.LANAccess (May disconnect CTC from node) |
Front & Backplane |
No LAN Access, Front Only, Backplane Only, Front & Backplane |
NODE.security.lanAccess.RestoreTimeout |
5 (minutes) |
0 - 60 |
NODE.security.legalDisclaimer.LoginWarningMessage |
<html><center><b>WARNING</b></center>This system is restricted to authorized users for business purposes. Unauthorized<p>access is a violation of the law. This service may be monitored for administrative<p>and security reasons. By proceeding, you consent to this monitoring. |
Free form field |
NODE.security.other.DisableInactiveUser |
FALSE |
FALSE, TRUE |
NODE.security.other.InactiveDuration |
45 (days) |
1, 2, 3 .. 99 when nothing TRUE; 45 when nothing FALSE |
NODE.security.other.SingleSessionPerUser |
FALSE |
TRUE, FALSE |
NODE.security.passwordAging.EnforcePasswordAging |
FALSE |
TRUE, FALSE |
NODE.security.passwordAging.maintenance.AgingPeriod |
45 (days) |
20 - 90 |
NODE.security.passwordAging.maintenance.WarningPeriod |
5 (days) |
2 - 20 |
NODE.security.passwordAging.provisioning.AgingPeriod |
45 (days) |
20 - 90 |
NODE.security.passwordAging.provisioning.WarningPeriod |
5 (days) |
2 - 20 |
NODE.security.passwordAging.retrieve.AgingPeriod |
45 (days) |
20 - 90 |
NODE.security.passwordAging.retrieve.WarningPeriod |
5 (days) |
2 - 20 |
NODE.security.passwordAging.superuser.AgingPeriod |
45 (days) |
20 - 90 |
NODE.security.passwordAging.superuser.WarningPeriod |
5 (days) |
2 - 20 |
NODE.security.passwordChange.CannotChangeNewPassword |
FALSE |
TRUE, FALSE |
NODE.security.passwordChange.CannotChangeNewPasswordForNDays |
20 (days) |
20 - 95 |
NODE.security.passwordChange.NewPasswordMustDifferFromOldByNCharacters |
1 (characters) |
1 - 5 |
NODE.security.passwordChange.PreventReusingLastNPasswords |
1 (times) |
1 - 10 |
NODE.security.passwordChange.RequirePasswordChangeOnFirstLoginToNewAccount |
FALSE |
TRUE, FALSE |
NODE.security.passwordComplexity.IdenticalConsecutiveCharactersAllowed |
3 or more |
0-2, 3 or more |
NODE.security.passwordComplexity.MaximumLength |
20 |
20, 80 |
NODE.security.passwordComplexity.MinimumLength |
6 |
6, 8, 10, 12 |
NODE.security.passwordComplexity.MinimumRequiredCharacters |
1 num, 1 letter & 1 TL1 special |
1 num, 1 letter & 1 TL1 special, 1 num, 1 letter & 1 special, 2 each of any 2 of num, upper, lower & TL1 special, 2 each of any 2 of num, upper, lower & special |
NODE.security.passwordComplexity.ReverseUserIdAllowed |
TRUE |
TRUE, FALSE |
NODE.security.radiusServer.AccountingPort |
1813 (port) |
0 - 32767 |
NODE.security.radiusServer.AuthenticationPort |
1812 (port) |
0 - 32767 |
NODE.security.radiusServer.EnableNodeAsFinalAuthenticator |
TRUE |
FALSE, TRUE |
NODE.security.serialCraftAccess.EnableCraftPort |
TRUE |
TRUE, FALSE |
NODE.security.shellAccess.AccessState |
NonSecure |
Disabled, NonSecure, Secure |
NODE.security.shellAccess.EnableShellPassword |
FALSE |
TRUE, FALSE |
NODE.security.shellAccess.TelnetPort |
23 |
23 - 9999 |
NODE.security.snmpAccess.AccessState |
NonSecure |
Disabled, NonSecure |
NODE.security.tl1Access.AccessState |
NonSecure |
Disabled, NonSecure, Secure |
NODE.security.userLockout.FailedLoginsAllowedBeforeLockout |
5 (times) |
0 - 10 |
NODE.security.userLockout.LockoutDuration |
00:30 (mins:secs) |
00:00, 00:05, 00:10 .. 10:00 |
NODE.security.userLockout.ManualUnlockBySuperuser |
FALSE |
TRUE, FALSE |
NODE.software.AllowDelayedUpgrades |
FALSE |
FALSE, TRUE |
NODE.software.DefaultDelayedUpgrades |
FALSE |
FALSE, TRUE when AllowDelayedUpgrades TRUE; FALSE when AllowDelayedUpgrades FALSE |
NODE.timing.bits-1.AdminSSMIn |
STU |
PRS, STU, ST2, ST3, SMC, ST4, DUS, RES when //.general.SSMMessageSet Generation 1; PRS, STU, ST2, TNC, ST3E, ST3, SMC, ST4, DUS, RES when //.general.SSMMessageSet Generation 2; G811, STU, G812T, G812L, SETS, DUS when //.general.SSMMessageSet N/A |
NODE.timing.bits-1.AISThreshold |
SMC |
PRS, STU, ST2, ST3, SMC, ST4, DUS, RES when //.general.SSMMessageSet Generation 1; PRS, STU, ST2, TNC, ST3E, ST3, SMC, ST4, DUS, RES when //.general.SSMMessageSet Generation 2; G811, STU, G812T, G812L, SETS, DUS when //.general.SSMMessageSet N/A |
NODE.timing.bits-1.Coding |
B8ZS |
B8ZS, AMI when FacilityType DS1; HDB3, AMI when FacilityType E1; N/A when FacilityType 2MHz; AMI when FacilityType 64kHz+8kHz |
NODE.timing.bits-1.CodingOut |
B8ZS |
B8ZS, AMI when FacilityTypeOut DS1; HDB3, AMI when FacilityTypeOut E1; N/A when FacilityTypeOut 2MHz; AMI when FacilityTypeOut 6MHz |
NODE.timing.bits-1.FacilityType |
DS1 |
DS1, 64kHz+8kHz when //.general.TimingStandard SONET; E1, 64kHz+8kHz, 2MHz when //.general.TimingStandard SDH |
NODE.timing.bits-1.FacilityTypeOut |
DS1 |
DS1, 6MHz when //.general.TimingStandard SONET; E1, 6MHz, 2MHz when //.general.TimingStandard SDH |
NODE.timing.bits-1.Framing |
ESF |
ESF, D4 when FacilityType DS1; FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed when FacilityType E1; N/A when FacilityType 2MHz; N/A when FacilityType 64kHz+8kHz |
NODE.timing.bits-1.FramingOut |
ESF |
ESF, D4 when FacilityTypeOut DS1; FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed when FacilityTypeOut E1; N/A when FacilityTypeOut 2MHz; N/A when FacilityTypeOut 6MHz |
NODE.timing.bits-1.LBO |
0-133 |
0-133, 134-266, 267-399, 400-533, 534-655 |
NODE.timing.bits-1.SaBit |
N/A |
N/A when FacilityType DS1; 4, 5, 6, 7, 8 when FacilityType E1; N/A when FacilityType 2MHz; N/A when FacilityType 64kHz+8kHz |
NODE.timing.bits-1.State |
OOS,DSBLD |
IS, OOS,DSBLD |
NODE.timing.bits-1.StateOut |
OOS,DSBLD |
IS, OOS,DSBLD |
NODE.timing.bits-2.AdminSSMIn |
STU |
PRS, STU, ST2, ST3, SMC, ST4, DUS, RES when //.general.SSMMessageSet Generation 1; PRS, STU, ST2, TNC, ST3E, ST3, SMC, ST4, DUS, RES when //.general.SSMMessageSet Generation 2; G811, STU, G812T, G812L, SETS, DUS when //.general.SSMMessageSet N/A |
NODE.timing.bits-2.AISThreshold |
SMC |
PRS, STU, ST2, ST3, SMC, ST4, DUS, RES when //.general.SSMMessageSet Generation 1; PRS, STU, ST2, TNC, ST3E, ST3, SMC, ST4, DUS, RES when //.general.SSMMessageSet Generation 2; G811, STU, G812T, G812L, SETS, DUS when //.general.SSMMessageSet N/A |
NODE.timing.bits-2.Coding |
B8ZS |
B8ZS, AMI when FacilityType DS1; HDB3, AMI when FacilityType E1; N/A when FacilityType 2MHz; AMI when FacilityType 64kHz+8kHz |
NODE.timing.bits-2.CodingOut |
B8ZS |
B8ZS, AMI when FacilityTypeOut DS1; HDB3, AMI when FacilityTypeOut E1; N/A when FacilityTypeOut 2MHz; AMI when FacilityTypeOut 6MHz |
NODE.timing.bits-2.FacilityType |
DS1 |
DS1, 64kHz+8kHz when //.general.TimingStandard SONET; E1, 64kHz+8kHz, 2MHz when //.general.TimingStandard SDH |
NODE.timing.bits-2.FacilityTypeOut |
DS1 |
DS1, 6MHz when //.general.TimingStandard SONET; E1, 6MHz, 2MHz when //.general.TimingStandard SDH |
NODE.timing.bits-2.Framing |
ESF |
ESF, D4 when FacilityType DS1; FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed when FacilityType E1; N/A when FacilityType 2MHz; N/A when FacilityType 64kHz+8kHz |
NODE.timing.bits-2.FramingOut |
ESF |
ESF, D4 when FacilityTypeOut DS1; FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed when FacilityTypeOut E1; N/A when FacilityTypeOut 2MHz; N/A when FacilityTypeOut 6MHz |
NODE.timing.bits-2.LBO |
0-133 |
0-133, 134-266, 267-399, 400-533, 534-655 |
NODE.timing.bits-2.SaBit |
N/A |
N/A when FacilityType DS1; 4, 5, 6, 7, 8 when FacilityType E1; N/A when FacilityType 2MHz; N/A when FacilityType 64kHz+8kHz |
NODE.timing.bits-2.State |
OOS,DSBLD |
IS, OOS,DSBLD |
NODE.timing.bits-2.StateOut |
OOS,DSBLD |
IS, OOS,DSBLD |
NODE.timing.general.Mode |
Line |
External, Line, Mixed |
NODE.timing.general.QualityOfRES |
RES=DUS |
PRS<RES, STU<RES<PRS, ST2<RES<STU, ST3<RES<ST2, SMC<RES<ST3, ST4<RES<SMC, RES<ST4, RES=DUS when SSMMessageSet Generation 1; PRS<RES, STU<RES<PRS, ST2<RES<STU, TNC<RES<ST2, ST3E<RES<TNC, ST3<RES<ST3E, SMC<RES<ST3, ST4<RES<SMC, RES<ST4, RES=DUS when SSMMessageSet Generation 2; N/A when SSMMessageSet N/A |
NODE.timing.general.ReversionTime |
5.0 (minutes) |
0.5, 1.0, 1.5 .. 12.0 |
NODE.timing.general.Revertive |
TRUE |
TRUE, FALSE |
NODE.timing.general.SSMMessageSet |
Generation 1 |
Generation 1, Generation 2 when TimingStandard SONET; N/A when TimingStandard SDH |
NODE.timing.general.TimingStandard |
SONET |
SONET, SDH |
C.2.2.1 Time Zones
Table C-17 lists the time zones that apply for node time zone defaults. Time zones in the table are ordered by their relative relationships to Greenwich Mean Time (GMT), and the default values are displayed in the correct format for valid default input.
C.3 CTC Default Settings
Table C-18 lists the CTC-level default settings for the Cisco ONS 15454. Cisco provides the following user-configurable defaults for CTC:
•Automatic Routing—Set circuit creation with the Route Automatically check box selected by default.
•Network Circuit Automatic Routing Overridable—Set by default whether or not a user creating circuits can change (override) the Automatic Circuit Routing setting (also provisionable as a default) in the CTC Circuit Routing Preferences area. When this default is set to TRUE it enables users to change whether or not Route Automatically is selected in the check box. When this default is set to FALSE it ensures that users cannot change the Route Automatically setting while creating circuits in CTC.
Note When the Route Automatically check box is not selectable (and is not checked) during circuit creation, the following automatic routing suboptions are also unavailable: Using Required Nodes/Spans, Review Route Before Creation, and VT-DS3 Mapped Conversion.
•Create TL1-like—Set whether to create only TL1-like circuits; that is, instruct the node to create only cross-connects, allowing the resulting circuits to be in an upgradable state.
•Local domain creation and viewing—Set whether domains that users create and view persist globally (all CTC sessions), or only locally (within the current CTC session).
•Network Map—Set the default network map (which country's map is displayed in CTC network view).
C.4 ETSI Platform Defaults
The following sections give the NE defaults for the ONS 15454 ETSI platform. To see defaults for the ONS 15454 ANSI platform, see the "ANSI Platform Defaults" section.
C.4.1 ETSI Card Defaults
The tables in this section list the default settings for each DWDM, Transponder (TXP), Muxponder (MXP), or Ethernet card. Cisco provides several types of user-configurable defaults for Cisco ONS 15454 DWDM, TXP, MXP, and Ethernet cards. Types of card defaults can be broadly grouped by function, as outlined in the following subsections. For information about individual card settings, refer to the "Provision Transponder and Muxponder Cards" chapter, or the "Change DWDM Card Settings" chapter in the Cisco ONS 15454 DWDM Procedure Guide.
Note The tables in this section list the default settings for each DWDM, TXP, and MXP card. For all other cards, including electrical, optical, Ethernet, and Fibre Channel, refer to the Cisco ONS 15454 Reference Manual or the Cisco ONS 15454 SDH Reference Manual.
Note When the card level defaults are changed, the new provisioning done after the defaults have changed is affected. Existing provisioning remains unaffected.
The following types of defaults are defined for DWDM, TXP, MXP, and Ethernet cards.
C.4.1.1 ETSI Configuration Defaults
Most card and port-level configuration defaults correspond to settings found in the CTC card-level Provisioning tabs.
Note The full set of Automatic Laser Shutdown (ALS) configuration defaults can be found in the CTC card-level Maintenance > ALS tab for supported cards. ALS defaults are supported for OSCM, OSC-CSM, OPT-BST, OPT-BST-L, GE_XP, 10GE_XP, TXP, and MXP cards. For information on how ALS card settings achieve network level optical safety, see Chapter 3, "Optical Service Channel Cards," Chapter 4, "Optical Amplifier Cards," or Chapter 8, "Transponder and Muxponder Cards."
Configuration defaults that are reachable from the CTC card-level Provisioning tabs (except as noted) include the following types of options (arranged by CTC subtab):
•Line—(GE_XP, 10GE_XP, TXP and MXP cards) Line-level configuration settings, including SONET, Wavelength Trunk, Trunk, Client, Distance Extension, and Enhanced FC/FICON ISL settings.
Note Some line configuration tabs, including Client, Distance Extension, and Enhanced FC/FICON ISL settings tabs, only appear in the card-level Provisioning > Line tab after a pluggable port module (PPM) is provisioned to a fibre channel payload type (port rate) for the particular card.
•OTN—(GE_XP, 10GE_XP, MXP-2.5G-10E, MXP-2_5G-10G, MXP-MR-10DME, TXP-MR-10E, TXP-MR-10G, TXP-MR-2.5G, and TXPP-MR-2.5G cards) Optical transport network (OTN) line configuration settings.
•Card—(See listed settings for applicable cards)
–Card mode—MXPP-MR-2.5G and MXP-MR-2.5G (ESCON, FC_GE, or MIXED), GE_XP (20GE MXP, 10GE MXP, or L2 over DWDM) , and 10GE_XP (10GE TXP or L2 over DWDM)
–Port range-level mode settings—MXP-MR-10DME cards only
–Termination mode—TXP-MR-10E, MXP-2.5G-10E, MXP-2.5G-10G, TXPP_MR_2.5G, TXP_MR_10G, and TXP_MR_2.5G cards
–AIS squelch settings—TXP-MR-10E and MXP-2.5G-10E cards
•ALS (card-level Maintenance > ALS tab)—(OSC-CSM, OSCM, OPT-BST, OPT-BST-L, GE_XP, 10GE_XP, TXP, and MXP cards) ALS configuration defaults.
Note For further information about supported features on each card, see Chapter 3, "Optical Service Channel Cards," Chapter 4, "Optical Amplifier Cards," or Chapter 8, "Transponder and Muxponder Cards."
C.4.1.2 ETSI Threshold Defaults
Threshold default settings define the default cumulative values (thresholds) beyond which a threshold crossing alert (TCA) will be raised, making it possible to monitor the network and detect errors early.
Card threshold default settings are provided as follows:
•PM thresholds—(OSCM, OSC-CSM, TXP and MXP cards) Expressed in counts or seconds; includes line and SDH thresholds.
•Optical thresholds—(GE_XP, 10GE_XP, TXP, and MXP cards) Expressed in percentages or dBm; includes client and trunk optical thresholds.
•OTN FEC thresholds (GE_XP, 10GE_XP, TXP, and MXP cards)—Expressed in counts; includes enhanced, standard, 1G Ethernet, 1G Fibre channel, 1G FICON, STM-1, STM-4, STM-16, 2G FICON, and 2G Fibre channel thresholds.
•OTN G.709 thresholds (GE_XP, 10GE_XP, TXP, and MXP cards)—Expressed in counts or seconds; includes ITU-T G.709 PM and SM thresholds.
Threshold defaults are defined for near end and/or far end, at 15-minute and one-day intervals. Thresholds are further broken down by type, such as Multiplex Section, Regeneration Section, VC LO, MS, RS, or Path, for performance monitoring (PM) thresholds, and TCA (warning) or Alarm for physical thresholds. PM threshold types define the layer to which the threshold applies. Physical threshold types define the level of response expected when the threshold is crossed.
Note For full descriptions of the thresholds you can set for each card, see Chapter 17, "Performance Monitoring."
Note In R7.0.1, when LOS, LOS-P, or LOF alarms occur on TXP and MXP trunks, certain TCAs are suppressed. For details, see Chapter 16, "Alarm and TCA Monitoring and Management."
Note For additional information regarding PM parameter threshold defaults as defined by Telcordia specifications, refer to Telcordia GR-820-CORE and GR-253-CORE.
C.4.1.3 ETSI Defaults by Card
In the tables that follow, card defaults are defined by the default name, its factory-configured value, and the domain of allowable values that you can assign to it.
Note Some default values, such as certain thresholds, are interdependent. Before changing a value, review the domain for that default and any other related defaults for potential dependencies.
C.4.1.3.1 ETSI ADM-10G Card Default Settings
Table C-19 lists the ADM-10G card default settings.
C.4.1.3.2 ETSI MS-ISC-100T Card Default Settings
Table C-20 lists the MS-ISC-100T card default settings.
C.4.1.3.3 ETSI MXP_2.5G_10E Card Default Settings
Table C-21 lists the MXP_2.5G_10E card default settings.
C.4.1.3.4 ETSI MXP_2.5G_10G Card Default Settings
Table C-22 lists the MXP_2.5G_10G card default settings.
C.4.1.3.5 ETSI MXP_MR_2.5G Card Default Settings
Table C-23 lists the MXP_MR_2.5G card default settings.
C.4.1.3.6 ETSI MXPP_MR_2.5G Card Default Settings
Table C-24 lists the MXPP_MR_2.5G card default settings.
C.4.1.3.7 ETSI MXP_MR_10DME_C and MXP_MR_10DME_L Card Default Settings
Table C-25 lists the MXP_MR_10DME_C and MXP_MR_10DME_L card default settings.
C.4.1.3.8 ETSI TXP_MR_10E Card Default Settings
Table C-26 lists the TXP_MR_10E card default settings.
C.4.1.3.9 ETSI TXP_MR_10G Card Default Settings
Table C-27 lists the TXP_MR_10G card default settings.
C.4.1.3.10 ETSI TXP_MR_2.5G Card Default Settings
Table C-28 lists the TXP_MR_2.5G card default settings.
C.4.1.3.11 ETSI TXPP_MR_2.5G Card Default Settings
Table C-29 lists the TXPP_MR_2.5G card default settings.
C.4.1.3.12 ETSI GE_XP Card Default Settings
Table C-30 lists the GE_XP card default settings.
C.4.1.3.13 ETSI 10GE_XP Card Default Settings
Table C-31 lists the 10GE_XP card default settings.
C.4.1.3.14 ETSI OSCM Card Default Settings
Table C-32 lists the OSCM card default settings.
C.4.1.3.15 ETSI OSC-CSM Card Default Settings
Table C-33 lists the OSC-CSM card default settings.
C.4.1.3.16 ETSI Amplifier Card Default Settings
Table C-34 lists the OPT-BST, OPT-AMP-17-C, and OPT-BST-L card default settings.
C.4.2 ETSI Node Default Settings
Table C-35 lists the Cisco ONS 15454 node-level default settings for the ETSI shelf assembly. Cisco provides the following types of user-configurable defaults for each Cisco ONS 15454 node:
•Circuit settings—Set the administrative state, subnetwork connection protection (SNCP) circuit threshold levels for signal degradation and failure, SNCP reversion time, and whether SNCP circuits are revertive by default.
•General settings—Set general node management defaults, including whether to use Daylight Savings Time (DST), the IP address of the NTP/SNTP server to be used, the time zone where the node is located, the SD path BER value, whether automatic autonomous TL1 reporting of PM data is enabled for cross-connect paths on the node, whether or not to allow ports to be disabled when they are providing services (when the default is set to FALSE users must remove or disable the services first, then put the ports out of service), and the defaults description.
•Link Management Protocol settings—Set link management protocol data link type, traffic engineering link, and general settings.
•Power Monitor settings—Set default voltage thresholds for the node.
•Network settings—Set whether to prevent display of node IP addresses in CTC (applicable for all users except Superusers); default gateway node type; whether to raise an alarm when the backplane LAN cable is disconnected; and whether to display the IP address in the LCD in an editable mode (in which you can change the IP address directly from LCD screen), to display the IP address on the LCD as read-only, or to suppress display of the IP on the LCD entirely.
•OSI settings—Set the Open System Interconnection (OSI) main setup, generic routing encapsulation (GRE) tunnel default, the link access protocol on the D channel (LAP-D), the router subnet, and the TID address resolution protocol (TARP) settings.
•Linear Multiplex Section Protection (LMSP) settings—Set whether or not protected circuits have bidirectional switching, are revertive, and what the reversion time is.
•MS-SPRing protection settings—Set whether MS-SPRing-protected circuits are revertive, and what the reversion time is, at both the ring and span levels.
•Y Cable protection settings—Set whether Y-cable protected circuits are revertive, and what the reversion time is.
•Splitter protection settings—Set whether splitter protected circuits are revertive, and what the reversion time is.
•Legal Disclaimer—Set the legal disclaimer that warns users at the login screen about the possible legal or contractual ramifications of accessing equipment, systems, or networks without authorization.
•Security Grant Permissions—Set default user security levels for activating/reverting software, PM data clearing, database restoring, and retrieving audit logs.
•Security DataComm settings—Set default security settings for TCC Ethernet IP address and IP netmask, and CTC backplane IP suppression; set secure mode on and secure mode locked (for TCC2P cards only).
•Security Access settings—Set default security settings for LAN access, shell access, serial craft access, element management system (EMS) access (including Internet Inter-Object Request Broker Protocol [IIOP] listener port number), TL1 access, and SNMP access.
•Security RADIUS settings—Set default RADIUS server settings for the accounting port number and the authentication port number, and whether to enable the node as a final authenticator.
•Security Policy settings—Set the allowable failed logins before lockout, idle user timeout for each user level, optional lockout duration or manual unlock enabled, password reuse and change frequency policies, number of characters difference that is required between the old and new password, password aging by security level, enforced single concurrent session per user, and option to disable inactive user after a set inactivity period.
•Security Password settings—Set when passwords can be changed, how many characters they must differ by, whether or not password reuse is allowed, and whether a password change is required on first login to a new account; set password aging enforcement and user-level specific aging and warning periods; set how many consecutive identical characters are allowed in a password, maximum password length, minimum password length, minimum number and combination of nonalphabetical characters required, and whether or not to allow a password that is a reversal of the login ID associated with the password.
•BITS Timing settings—Set the AIS threshold, Admin synchronization status messaging (SSM), coding, facility type, framing, state, and Sa bit (the overhead bit that will carry the SSM) for building integrated timing supply 1 (BITS-1) and BITS2 timing.
•General Timing settings—Set the mode (External, Line, or Mixed), revertive, and reversion time.
Note Any node level defaults changed using the Provisioning > Defaults tab, changes existing node level provisioning. Although this is service affecting, it depends on the type of defaults changed, for example, general, and all timing and security attributes. The "Changing default values for some node level attributes overrides the current provisioning." message is displayed. The Side Effects column of the Defaults editor (right-click a column header and select Show Column > Side Effects) explains the effect of changing the default values. However, when the card level defaults are changed using the Provisioning > Defaults tab, existing card provisioning remains unaffected.
Note For more information about each individual node setting, refer to the "Manage the Node" chapter in the Cisco ONS 15454 DWDM Procedure Guide.
Note Refer to the CTC Default Settings for CTC-level default settings for the Cisco ONS 15454.
|
|
|
---|---|---|
NODE.circuits.State |
unlocked, automaticInService |
unlocked, locked, disabled, locked, maintenance, unlocked, automaticInService |
NODE.circuits.sncp.HO_SDBER |
1E-6 |
1E-5, 1E-6, 1E-7, 1E-8, 1E-9 |
NODE.circuits.sncp.HO_SFBER |
1E-4 |
1E-3, 1E-4, 1E-5 |
NODE.circuits.sncp.LO_SDBER |
1E-6 |
1E-5, 1E-6, 1E-7, 1E-8 |
NODE.circuits.sncp.LO_SFBER |
1E-4 |
1E-3, 1E-4, 1E-5 |
NODE.circuits.sncp.ProvisionWorkingGoAndReturnOnPrimaryPath |
FALSE |
TRUE, FALSE |
NODE.circuits.sncp.ReversionTime |
5.0 (minutes) |
0.5, 1.0, 1.5 .. 12.0 |
NODE.circuits.sncp.Revertive |
FALSE |
TRUE, FALSE |
NODE.general.AllowServiceAffectingPortChangeToDisabled |
TRUE |
FALSE, TRUE |
NODE.general.AutoPM |
FALSE |
FALSE, TRUE |
NODE.general.DefaultsDescription |
Factory Defaults |
Free form field |
NODE.general.NtpSntpServer |
0.0.0.0 |
IP Address |
NODE.general.ReportLoopbackConditionsOnLocked,MaintenancePorts |
FALSE |
FALSE, TRUE |
NODE.general.TimeZone |
(GMT-08:00) Pacific Time (US & Canada), Tijuana |
(For applicable time zones, see Table C-17.) |
NODE.general.UseDST |
TRUE |
TRUE, FALSE |
NODE.lmp.controlChannel.AdminState |
locked, disabled |
unlocked, locked, disabled |
NODE.lmp.controlChannel.HelloDeadInterval |
12000 (ms) |
maximum_of(2000,MinHelloDeadInterval,product_of(HelloInterval,3)), maximum_of(2000,MinHelloDeadInterval,product_of(HelloInterval,3)) + 1, maximum_of(2000,MinHelloDeadInterval,product_of(HelloInterval,3)) + 2 .. minimum_of(20000,MaxHelloDeadInterval) |
NODE.lmp.controlChannel.HelloInterval |
500 (ms) |
maximum_of(300,MinHelloInterval), maximum_of(300,MinHelloInterval) + 1, maximum_of(300,MinHelloInterval) + 2 .. minimum_of(5000,MaxHelloInterval,quotient_of(HelloDeadInterval,3)) |
NODE.lmp.controlChannel.MaxHelloDeadInterval |
20000 (ms) |
maximum_of(2000,HelloDeadInterval,sum_of(MaxHelloInterval,1)), maximum_of(2000,HelloDeadInterval,sum_of(MaxHelloInterval,1)) + 1, maximum_of(2000,HelloDeadInterval,sum_of(MaxHelloInterval,1)) + 2 .. 20000 |
NODE.lmp.controlChannel.MaxHelloInterval |
2000 (ms) |
maximum_of(300,HelloInterval), maximum_of(300,HelloInterval) + 1, maximum_of(300,HelloInterval) + 2 .. minimum_of(5000,difference_of(MaxHelloDeadInterval,1)) |
NODE.lmp.controlChannel.MinHelloDeadInterval |
2000 (ms) |
maximum_of(2000,sum_of(MinHelloInterval,1)), maximum_of(2000,sum_of(MinHelloInterval,1)) + 1, maximum_of(2000,sum_of(MinHelloInterval,1)) + 2 .. minimum_of(20000,HelloDeadInterval) |
NODE.lmp.controlChannel.MinHelloInterval |
300 (ms) |
300, 301, 302 .. minimum_of(5000,HelloInterval,difference_of(MinHelloDeadInterval,1)) |
NODE.lmp.dataLink.Type |
Port |
Port, Component |
NODE.lmp.general.Allowed |
TRUE |
FALSE, TRUE |
NODE.lmp.general.Enabled |
FALSE |
FALSE, TRUE when Allowed TRUE; FALSE when Allowed FALSE |
NODE.lmp.general.LMP-WDM |
TRUE |
FALSE, TRUE |
NODE.lmp.general.Role |
OLS |
PEER, OLS |
NODE.lmp.teLink.AdminState |
locked, disabled |
unlocked, locked, disabled |
NODE.lmp.teLink.DWDM |
TRUE |
FALSE, TRUE |
NODE.lmp.teLink.MuxCapability |
Lambda Switch |
Packet Switch - Level 1, Packet Switch - Level 2, Packet Switch - Level 3, Packet Switch - Level 4, Layer 2 Switch, TDM Cross-connect, Lambda Switch, Fiber Switch |
NODE.network.general.AlarmMissingBackplaneLAN |
FALSE |
TRUE, FALSE |
NODE.network.general.CtcIpDisplaySuppression |
FALSE |
TRUE, FALSE |
NODE.network.general.GatewaySettings |
None |
LeaveAsIs, None, ENE, GNE, ProxyOnlyNode |
NODE.network.general.LcdSetting |
Allow Configuration |
Allow Configuration, Display Only, Suppress Display |
NODE.osi.greTunnel.OspfCost |
110 |
110 - 65535 |
NODE.osi.greTunnel.SubnetMask |
24 (bits) |
8, 9, 10 .. 32 |
NODE.osi.lapd.MTU |
512 |
512, 513, 514 .. 1500 |
NODE.osi.lapd.Mode |
AITS |
AITS, UITS |
NODE.osi.lapd.Role |
Network |
Network, User |
NODE.osi.lapd.T200 |
200 (ms) |
200, 300, 400 .. 20000 |
NODE.osi.lapd.T203 |
10000 (ms) |
4000, 4100, 4200 .. 120000 |
NODE.osi.mainSetup.L1L2LSPBufferSize |
512 (bytes) |
512 - 1500 |
NODE.osi.mainSetup.L1LSPBufferSize |
512 (bytes) |
512 - 1500 |
NODE.osi.mainSetup.NodeRoutingMode |
Intermediate System Level 1 |
End System, Intermediate System Level 1, Intermediate System Level 1/Level 2 |
NODE.osi.subnet.DISPriority |
63 |
1, 2, 3 .. 127 |
NODE.osi.subnet.ESH |
10 (sec) |
10, 20, 30 .. 1000 |
NODE.osi.subnet.GCCISISCost |
60 |
1, 2, 3 .. 63 |
NODE.osi.subnet.IIH |
3 (sec) |
1, 2, 3 .. 600 |
NODE.osi.subnet.ISH |
10 (sec) |
10, 20, 30 .. 1000 |
NODE.osi.subnet.LANISISCost |
20 |
1, 2, 3 .. 63 |
NODE.osi.subnet.LDCCISISCost |
40 |
1, 2, 3 .. 63 |
NODE.osi.subnet.OSCISISCost |
60 |
1, 2, 3 .. 63 |
NODE.osi.subnet.SDCCISISCost |
60 |
1, 2, 3 .. 63 |
NODE.osi.tarp.L1DataCache |
TRUE |
FALSE, TRUE |
NODE.osi.tarp.L2DataCache |
FALSE |
FALSE, TRUE |
NODE.osi.tarp.LANStormSuppression |
TRUE |
FALSE, TRUE |
NODE.osi.tarp.LDB |
TRUE |
FALSE, TRUE |
NODE.osi.tarp.LDBEntry |
5 (min) |
1 - 10 |
NODE.osi.tarp.LDBFlush |
5 (min) |
0 - 1440 |
NODE.osi.tarp.PDUsL1Propagation |
TRUE |
FALSE, TRUE |
NODE.osi.tarp.PDUsL2Propagation |
TRUE |
FALSE, TRUE |
NODE.osi.tarp.PDUsOrigination |
TRUE |
FALSE, TRUE |
NODE.osi.tarp.T1Timer |
15 (sec) |
0 - 3600 |
NODE.osi.tarp.T2Timer |
25 (sec) |
0 - 3600 |
NODE.osi.tarp.T3Timer |
40 (sec) |
0 - 3600 |
NODE.osi.tarp.T4Timer |
20 (sec) |
0 - 3600 |
NODE.osi.tarp.Type4PDUDelay |
0 (sec) |
0 - 255 |
NODE.powerMonitor.EHIBATVG_48V |
-56.5 (Vdc) |
-40.5, -41.0, -41.5 .. -57.0 |
NODE.powerMonitor.EHIBATVG_60V |
-72.0 (Vdc) |
-50.0, -50.5, -51.0 .. -72.0 |
NODE.powerMonitor.ELWBATVG_48V |
-40.5 (Vdc) |
-40.5, -41.0, -41.5 .. -56.5 |
NODE.powerMonitor.ELWBATVG_60V |
-50.0 (Vdc) |
-50.0, -50.5, -51.0 .. -72.0 |
NODE.protection.lmsp.BidirectionalSwitching |
FALSE |
TRUE, FALSE |
NODE.protection.lmsp.ReversionTime |
5.0 (minutes) |
0.5, 1.0, 1.5 .. 12.0 |
NODE.protection.lmsp.Revertive |
FALSE |
TRUE, FALSE |
NODE.protection.msspr.RingReversionTime |
5.0 (minutes) |
0.5, 1.0, 1.5 .. 12.0 |
NODE.protection.msspr.RingRevertive |
TRUE |
TRUE, FALSE |
NODE.protection.msspr.SpanReversionTime |
5.0 (minutes) |
0.5, 1.0, 1.5 .. 12.0 |
NODE.protection.msspr.SpanRevertive |
TRUE |
TRUE, FALSE |
NODE.protection.splitter.ReversionTime |
5.0 (minutes) |
0.5, 1.0, 1.5 .. 12.0 |
NODE.protection.splitter.Revertive |
FALSE |
TRUE, FALSE |
NODE.protection.ycable.ReversionTime |
5.0 (minutes) |
0.5, 1.0, 1.5 .. 12.0 |
NODE.protection.ycable.Revertive |
FALSE |
TRUE, FALSE |
NODE.security.dataComm.CtcBackplaneIpDisplaySuppression |
TRUE |
FALSE, TRUE when isSecureModeSupportedOnControlCard TRUE; (NOT SUPPORTED) when isSecureModeSupportedOnControlCard FALSE |
NODE.security.dataComm.DefaultTCCEthernetIP |
10.0.0.1 |
IP Address |
NODE.security.dataComm.DefaultTCCEthernetIPNetmask |
24 (bits) |
8, 9, 10 .. 32 |
NODE.security.dataComm.LcdBackplaneIpSetting |
Display Only |
Allow Configuration, Display Only, Suppress Display when isSecureModeSupportedOnControlCard TRUE; (NOT SUPPORTED) when isSecureModeSupportedOnControlCard FALSE |
NODE.security.dataComm.SecureModeLocked |
FALSE |
FALSE, TRUE when isSecureModeSupportedOnControlCard TRUE; (NOT SUPPORTED) when isSecureModeSupportedOnControlCard FALSE |
NODE.security.dataComm.SecureModeOn (May reboot node) |
FALSE |
FALSE, TRUE when isSecureModeSupportedOnControlCard TRUE; (NOT SUPPORTED) when isSecureModeSupportedOnControlCard FALSE |
NODE.security.dataComm.isSecureModeSupportedOnControlCard |
TRUE |
FALSE, TRUE |
NODE.security.emsAccess.AccessState |
NonSecure |
NonSecure, Secure |
NODE.security.emsAccess.IIOPListenerPort (May reboot node) |
57790 (port #) |
0 - 65535 |
NODE.security.grantPermission.ActivateRevertSoftware |
Superuser |
Provisioning, Superuser |
NODE.security.grantPermission.PMClearingPrivilege |
Provisioning |
Provisioning, Superuser |
NODE.security.grantPermission.RestoreDB |
Superuser |
Provisioning, Superuser |
NODE.security.grantPermission.RetrieveAuditLog |
Superuser |
Provisioning, Superuser |
NODE.security.idleUserTimeout.Maintenance |
01:00 (hours:mins) |
00:00, 00:01, 00:02 .. 16:39 |
NODE.security.idleUserTimeout.Provisioning |
00:30 (hours:mins) |
00:00, 00:01, 00:02 .. 16:39 |
NODE.security.idleUserTimeout.Retrieve |
00:00 (hours:mins) |
00:00, 00:01, 00:02 .. 16:39 |
NODE.security.idleUserTimeout.Superuser |
00:15 (hours:mins) |
00:00, 00:01, 00:02 .. 16:39 |
NODE.security.lanAccess.LANAccess (May disconnect CTC from node) |
Front & Backplane |
No LAN Access, Front Only, Backplane Only, Front & Backplane |
NODE.security.lanAccess.RestoreTimeout |
5 (minutes) |
0 - 60 |
NODE.security.legalDisclaimer.LoginWarningMessage |
<html><center><b>WARNING</b></center>This system is restricted to authorized users for business purposes. Unauthorized<p>access is a violation of the law. This service may be monitored for administrative<p>and security reasons. By proceeding, you consent to this monitoring. |
Free form field |
NODE.security.other.DisableInactiveUser |
FALSE |
FALSE, TRUE |
NODE.security.other.InactiveDuration |
45 (days) |
1, 2, 3 .. 99 when nothing TRUE; 45 when nothing FALSE |
NODE.security.other.PreventInactiveSuperuserDisable |
FALSE |
TRUE, FALSE |
NODE.security.other.SingleSessionPerUser |
FALSE |
TRUE, FALSE |
NODE.security.passwordAging.EnforcePasswordAging |
FALSE |
TRUE, FALSE |
NODE.security.passwordAging.maintenance.AgingPeriod |
45 (days) |
20 - 90 |
NODE.security.passwordAging.maintenance.WarningPeriod |
5 (days) |
2 - 20 |
NODE.security.passwordAging.provisioning.AgingPeriod |
45 (days) |
20 - 90 |
NODE.security.passwordAging.provisioning.WarningPeriod |
5 (days) |
2 - 20 |
NODE.security.passwordAging.retrieve.AgingPeriod |
45 (days) |
20 - 90 |
NODE.security.passwordAging.retrieve.WarningPeriod |
5 (days) |
2 - 20 |
NODE.security.passwordAging.superuser.AgingPeriod |
45 (days) |
20 - 90 |
NODE.security.passwordAging.superuser.WarningPeriod |
5 (days) |
2 - 20 |
NODE.security.passwordChange.CannotChangeNewPassword |
FALSE |
TRUE, FALSE |
NODE.security.passwordChange.CannotChangeNewPasswordForNDays |
20 (days) |
20 - 95 |
NODE.security.passwordChange.NewPasswordMustDifferFromOldByNCharacters |
1 (characters) |
1 - 5 |
NODE.security.passwordChange.PreventReusingLastNPasswords |
1 (times) |
1 - 10 |
NODE.security.passwordChange.RequirePasswordChangeOnFirstLoginToNewAccount |
FALSE |
TRUE, FALSE |
NODE.security.passwordComplexity.IdenticalConsecutiveCharactersAllowed |
3 or more |
0-2, 3 or more |
NODE.security.passwordComplexity.MaximumLength |
20 |
20, 80 |
NODE.security.passwordComplexity.MinimumLength |
6 |
6, 8, 10, 12 |
NODE.security.passwordComplexity.MinimumRequiredCharacters |
1 num, 1 letter & 1 TL1 special |
1 num, 1 letter & 1 TL1 special, 1 num, 1 letter & 1 special, 2 each of any 2 of num, upper, lower & TL1 special, 2 each of any 2 of num, upper, lower & special |
NODE.security.passwordComplexity.ReverseUserIdAllowed |
TRUE |
TRUE, FALSE |
NODE.security.radiusServer.AccountingPort |
1813 (port) |
0 - 32767 |
NODE.security.radiusServer.AuthenticationPort |
1812 (port) |
0 - 32767 |
NODE.security.radiusServer.EnableNodeAsFinalAuthenticator |
TRUE |
FALSE, TRUE |
NODE.security.serialCraftAccess.EnableCraftPort |
TRUE |
TRUE, FALSE |
NODE.security.shellAccess.AccessState |
NonSecure |
Disabled, NonSecure, Secure |
NODE.security.shellAccess.EnableShellPassword |
FALSE |
TRUE, FALSE |
NODE.security.shellAccess.TelnetPort |
23 |
23 - 9999 |
NODE.security.snmpAccess.AccessState |
NonSecure |
Disabled, NonSecure |
NODE.security.tl1Access.AccessState |
NonSecure |
Disabled, NonSecure, Secure |
NODE.security.userLockout.FailedLoginsAllowedBeforeLockout |
5 (times) |
0 - 10 |
NODE.security.userLockout.LockoutDuration |
00:30 (mins:secs) |
00:00, 00:05, 00:10 .. 10:00 |
NODE.security.userLockout.ManualUnlockBySuperuser |
FALSE |
TRUE, FALSE |
NODE.software.AllowDelayedUpgrades |
FALSE |
FALSE, TRUE |
NODE.software.DefaultDelayedUpgrades |
FALSE |
FALSE, TRUE when AllowDelayedUpgrades TRUE; FALSE when AllowDelayedUpgrades FALSE |
NODE.timing.bits-1.AISThreshold |
DUS |
G811, STU, G812T, G812L, SETS, DUS |
NODE.timing.bits-1.AdminSSMIn |
STU |
G811, STU, G812T, G812L, SETS, DUS |
NODE.timing.bits-1.Coding |
HDB3 |
HDB3, AMI when FacilityType E1; N/A when FacilityType 2MHz; AMI when FacilityType 64kHz+8kHz |
NODE.timing.bits-1.CodingOut |
HDB3 |
HDB3, AMI when FacilityTypeOut E1; N/A when FacilityTypeOut 2MHz; AMI when FacilityTypeOut 6MHz |
NODE.timing.bits-1.FacilityType |
E1 |
E1, 64kHz+8kHz, 2MHz |
NODE.timing.bits-1.FacilityTypeOut |
E1 |
E1, 6MHz, 2MHz |
NODE.timing.bits-1.Framing |
FAS+CAS+CRC |
FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed when FacilityType E1; N/A when FacilityType 2MHz; FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed, Unframed - 2Mhz when FacilityType 64kHz+8kHz |
NODE.timing.bits-1.FramingOut |
FAS+CAS+CRC |
FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed when FacilityTypeOut E1; N/A when FacilityTypeOut 2MHz; FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed, Unframed - 2Mhz when FacilityTypeOut 6MHz |
NODE.timing.bits-1.SaBit |
4 |
4, 5, 6, 7, 8 when FacilityType E1; N/A when FacilityType 2MHz; N/A when FacilityType 64kHz+8kHz |
NODE.timing.bits-1.State |
unlocked |
unlocked, locked, disabled |
NODE.timing.bits-1.StateOut |
unlocked |
unlocked, locked, disabled |
NODE.timing.bits-2.AISThreshold |
DUS |
G811, STU, G812T, G812L, SETS, DUS |
NODE.timing.bits-2.AdminSSMIn |
STU |
G811, STU, G812T, G812L, SETS, DUS |
NODE.timing.bits-2.Coding |
HDB3 |
HDB3, AMI when FacilityType E1; N/A when FacilityType 2MHz; AMI when FacilityType 64kHz+8kHz |
NODE.timing.bits-2.CodingOut |
HDB3 |
HDB3, AMI when FacilityTypeOut E1; N/A when FacilityTypeOut 2MHz; AMI when FacilityTypeOut 6MHz |
NODE.timing.bits-2.FacilityType |
E1 |
E1, 64kHz+8kHz, 2MHz |
NODE.timing.bits-2.FacilityTypeOut |
E1 |
E1, 6MHz, 2MHz |
NODE.timing.bits-2.Framing |
FAS+CAS+CRC |
FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed when FacilityType E1; N/A when FacilityType 2MHz; FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed, Unframed - 2Mhz when FacilityType 64kHz+8kHz |
NODE.timing.bits-2.FramingOut |
FAS+CAS+CRC |
FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed when FacilityTypeOut E1; N/A when FacilityTypeOut 2MHz; FAS+CRC, FAS+CAS, FAS+CAS+CRC, FAS, Unframed, Unframed - 2Mhz when FacilityTypeOut 6MHz |
NODE.timing.bits-2.SaBit |
4 |
4, 5, 6, 7, 8 when FacilityType E1; N/A when FacilityType 2MHz; N/A when FacilityType 64kHz+8kHz |
NODE.timing.bits-2.State |
unlocked |
unlocked, locked, disabled |
NODE.timing.bits-2.StateOut |
unlocked |
unlocked, locked, disabled |
NODE.timing.general.Mode |
External |
External, Line, Mixed |
NODE.timing.general.ReversionTime |
5.0 (minutes) |
0.5, 1.0, 1.5 .. 12.0 |
NODE.timing.general.Revertive |
FALSE |
TRUE, FALSE |