Supported Cards and Pluggables

Supported Transponder Cards and Pluggables

Table 1. Feature History

Feature Name

Release Information

Feature Description

Pluggable Support

Cisco ONP Release 4.1

QSFP-100G-FR-S= pluggable is supported on the QSFP ports of the 400G-XP LC transponder card with 100GE data rate.

QSFP-100G-ERL-S Pluggable

Cisco ONP Release 5.1

The new QSFP-100G-ERL-S pluggable enables you to design and validate topologies for NCS 2000 R11.1.3 networks. This pluggable is supported on the QSFP ports of the 400G-XP-LC transponder card with 100GE data rate. You can select this pluggable from the Client Interface drop-down list at trail level properties for the 400G-XP-LC transponder card.

Cisco ONP supports the following transponders and pluggables for NCS 2000 networks:

Table 2. Supported Transponder Cards and Pluggables for NCS 2000 Network
Transponder/ Muxponder Traffic Type FEC mode Pluggables Supported Encryption SSON Encryption Non-SSON Trunk Mode
200G-CK-LC + MR-MXP (200G MXP mode)
  • 100GE

  • OTU4

SD-FEC_20
  • SR-1(CPAK-100G-SR10)

  • SR-1(CPAK-100G-SR4)

  • LR-1(CPAK-100G-LR4)

  • SR-1(CPAK-100G-SR10)

  • LR-1(CPAK-100G-LR4)

Yes (only for 100GE) No Auto, TRK_200G
200G-CK-LC + MR-MXP (100G TXP mode) 100GE SD-FEC_20
  • SR-1(CPAK-100G-SR10)

  • SR-1(CPAK-100G-SR4

  • LR-1(CPAK-100G-LR4)

Yes Yes Auto, TRK_100G
200G-CK-LC + MR-MXP (100G TXP mode) 100GE SD-EFEC
  • SR-1(CPAK-100G-SR10)

  • SR-1(CPAK-100G-SR4

  • LR-1(CPAK-100G-LR4)

Yes Yes Auto, TRK_100G
200G-CK-LC + MR-MXP (100G TXP mode)

100GE

SD-FEC
  • SR-1(CPAK-100G-SR10)

  • SR-1(CPAK-100G-SR4

  • LR-1(CPAK-100G-LR4)

Yes Yes Auto, TRK_100G
200G-CK-LC + MR-MXP (100G MXP mode)
  • 10GE

  • 10GE LAN PHY

  • OC192

  • OTU2

SD-FEC_20
  • LR-1(ONS-QSFP-4*10G-MLR)

  • LR-1(QSFP-4*10G-MLR)

  • SR-1(QSFP-40G-SR4)

  • SR-1(ONS-SC+10G-SR)

  • LR-1(ONS-SC+10G-LR)

  • DWDM(ONS-SC+-10G-C)

  • DWDM(ONS-SC+-10GEPxx.x)

Yes Yes Auto, TRK_100G
200G-CK-LC + MR-MXP (100G MXP mode)
  • 10GE

  • 10GE LAN PHY

  • OC192

  • OTU2

SD-EFEC
  • LR-1(ONS-QSFP-4*10G-MLR)

  • LR-1(QSFP-4*10G-MLR)

  • SR-1(QSFP-40G-SR4)

  • SR-1(ONS-SC+10G-SR)

  • LR-1(ONS-SC+10G-LR)

  • DWDM(ONS-SC+-10G-C)

  • DWDM(ONS-SC+-10GEPxx.x)

Yes Yes Auto, TRK_100G
200G-CK-LC + MR-MXP (100G MXP mode)
  • 10GE LAN PHY

  • 10GE

  • OC192

  • OTU2

SD-FEC
  • LR-1(ONS-QSFP-4*10G-MLR)

  • LR-1(QSFP-4*10G-MLR)

  • SR-1(QSFP-40G-SR4)

  • SR-1(ONS-SC+10G-SR)

  • LR-1(ONS-SC+10G-LR)

  • DWDM(ONS-SC+-10G-C)

  • DWDM(ONS-SC+-10GEPxx.x)

Yes Yes Auto, TRK_100G
200G-CK-LC + MR-MXP (100G MXP mode 2*10G 2*40G MODE)
  • 10GE

  • 10GE LAN PHY

  • 40GE

SD-FEC_20
  • SR-1(ONS-SC+10G-SR)

  • LR-1(ONS-SC+10G-LR)

  • DWDM(ONS-SC+-10G-C)

  • LR-1(QSFP-40G-LR4)

  • DWDM(ONS-SC+-10GEPxx.x)

  • SR-1(QSFP-40G-SR4)

  • SR-1(QSFP-40G-SR-BD)

Yes Yes Auto, TRK_100G
200G - CK-LC + MR - MXP (100G MXP mode 2*10G 2*40G MODE)
  • 10GE

  • 40GE

SD-EFEC
  • SR-1(ONS-SC+10G-SR)

  • LR-1(ONS-SC+10G-LR)

  • DWDM(ONS-SC+-10G-C)

  • DWDM(ONS-SC+-10GEPxx.x)

  • SR-1(QSFP-40G-SR4)

  • LR-1(QSFP-40G-LR4)

  • SR-1(QSFP-40G-SR-BD)

Yes Yes Auto, TRK_100G
200G - CK-LC + MR -MXP (100G MXP mode 2*10G 2*40G MODE)
  • 10GE

  • 40GE

SD-FEC
  • SR-1(ONS-SC+10G-SR)

  • LR-1(ONS-SC+10G-LR)

  • DWDM(ONS-SC+-10G-C)

  • DWDM(ONS-SC+-10GEPxx.x)

  • SR-1(QSFP-40G-SR4)

  • LR-1(QSFP-40G-LR4)

  • SR-1(QSFP-40G-SR-BD)

Yes Yes Auto, TRK_100G
200G - CK-LC +10x10G -LC
  • 10GE

  • OC192

  • OTU2

  • OTU2e

SD- FEC_20
  • SR-1(ONS-SC+-10G-SR)

  • LR-1(ONS-SC+-10G-LR

  • DWDM(ONS-SC+-10G-C)

  • DWDM(ONS-SC+-10GEPxx.x)

  • ER(ONS-SC+-10G-ER)

  • ZR (ONS-SC+-10G-ZR)

  • DWDM(ONS-SC+-10G-xx.x)

Yes for OTU2e No Auto, TRK_100G
200G - CK-LC +10x10G -LC
  • 10GE

  • OC192

  • OTU2

  • OTU2e

SD-EFEC
  • SR-1(ONS-SC+-10G-SR)

  • LR-1(ONS-SC+-10G-LR

  • DWDM(ONS-SC+-10G-C)

  • DWDM(ONS-SC+-10GEPxx.x)

  • ER (ONS-SC+-10G-ER)

  • ZR (ONS-SC+-10G-ZR)

  • DWDM(ONS-SC+-10G-xx.x)

Yes for OTU2e No Auto, TRK_100G
200G-CK-LC + 10x10G -LC
  • 10GE

  • OC192

  • OTU2

  • OTU2e

SD-FEC
  • SR-1(ONS-SC+-10G-SR)

  • LR-1(ONS-SC+-10G-LR

  • DWDM(ONS-SC+-10G-C)

  • DWDM(ONS-SC+-10GEPxx.x)

  • ER(ONS-SC+-10G-ER)

  • ZR(ONS-SC+-10G-ZR)

  • DWDM(ONS-SC+-10G-xx.x)

Yes for OTU2e No Auto, TRK_100G
200G - CK-LC + MR-MXP (200G Mxp 100G+10*10G Mode)
  • 100GE

  • 10GE

  • OC192

  • OTU2

SD- FEC_20
  • SR-1(CPAK-100G-SR10)

  • SR-1(CPAK-100G-SR4)

  • LR-1(CPAK-100G-LR4)

  • SR-1(ONS-SC+-10G-SR)

  • LR-1(ONS-SC+-10G-LR)

  • DWDM(ONS-SC+-10G-C)

  • DWDM(ONS-SC+-10GEPxx.x)

  • ER(ONS-SC+-10G-ER)

  • ZR(ONS-SC+-10G-ZR)

  • DWDM(ONS-SC+-10G-xx.x)

Yes for 100GE and OTU2 No Auto, TRK_200G
200G-CK-LC + MR-MXP + MR-MXP (200G Mxp 4*40G + 4*10G Mode)
  • 10GE

  • 10GE LAN PHY

  • 40GE

SD- FEC_20
  • SR-1(ONS-SC+-10G-SR)

  • LR-1(ONS-SC+-10G-LR)

  • DWDM(ONS-SC+-10G-C)

  • DWDM(ONS-SC+-10GEPxx.x)

  • SR-1(QSFP-40G-SR4)

  • LR-1(QSFP-40G-LR4)

  • SR-1(QSFP-40G-SR-BD)

Yes Yes Auto, TRK_200G
200G-CK-LC + 10x10G -LC + MR-MXP
  • 10GE

  • OC192

  • OTU2

SD- FEC_20
  • SR-1(ONS-SC+-10G-SR)

  • LR-1(ONS-SC+-10G-LR)

  • DWDM(ONS-SC+-10G-C)

  • DWDM(ONS-SC+-10GEPxx.x)

  • ER(ONS-SC+-10G-ER)

  • ZR(ONS-SC+-10G-ZR)

  • DWDM(ONS-SC+-10G-xx.x)

  • LR-1(ONS-QSFP-4*10G-MLR)

  • ZR(ONS-SC+-10G-ZR)

Yes Yes Auto, TRK_200G
200G-CK-LC + MR-MXP + MR-MXP
  • 10GE

  • OC192

  • OTU2

SD-FEC_20
  • SR-1(ONS-SC+-10G-SR)

  • LR-1(ONS-SC+-10G-LR)

  • DWDM(ONS-SC+-10G-C)

  • DWDM(ONS-SC+-10GEPxx.x)

  • ER(ONS-SC+-10G-ER)

  • ZR(ONS-SC+-10G-ZR)

  • DWDM(ONS-SC+-10G-xx.x)

  • LR-1(ONS-QSFP-4*10G-MLR)

  • ZR(ONS-SC+-10G-ZR)

Yes Yes Auto, TRK_200G
100GS - CK-LC + 10x10G-LC
  • 10GE

  • OC192

EFEC, SD-FEC_20
  • SR-1(ONS-SC+-10G-SR)

  • LR-1(ONS-SC+-10G-LR)

  • DWDM(ONS-SC+-10G-C)

  • DWDM(ONS-SC+-10GEPxx.x)

  • ER(ONS-SC+-10G-ER)

  • ZR(ONS-SC+-10G-ZR)

  • DWDM(ONS-SC+-10G-xx.x)

No No Auto, TRK_100G
100G - LC-C + 10x10G-LC
  • 10GE

  • OC192

  • Fiber Channel 10G

  • Fiber Channel 8G

  • OTU2

  • OTU2e

FEC
  • SR-1(ONS-SC+-10G-SR)

  • LR-1(ONS-SC+-10G-LR)

  • DWDM(ONS-SC+-10G-C)

  • DWDM(ONS-SC+-10GEPxx.x)

  • ER(ONS-SC+-10G-ER)

  • ZR(ONS-SC+-10G-ZR)

  • DWDM(ONS-SC+-10G-xx.x)

No No Auto
100G - LC-C + 10x10G-LC
  • 10GE

  • OC192

  • Fiber Channel 10G

  • Fiber Channel 8G

  • OTU2

  • OTU2e

EFEC
  • SR-1(ONS-SC+-10G-SR)

  • LR-1(ONS-SC+-10G-LR)

  • DWDM(ONS-SC+-10G-C)

  • DWDM(ONS-SC+-10GEPxx.x)

  • ER (ONS-SC+-10G-ER)

  • ZR(ONS-SC+-10G-ZR)

  • DWDM(ONS-SC+-10G-xx.x)

No No Auto
100G - LC-C + 10x10G-LC
  • 10GE

  • OC192

  • Fiber Channel 10G

  • Fiber Channel 8G

  • OTU2

  • OTU2e

HG-FEC
  • SR-1(ONS-SC+-10G-SR)

  • LR-1(ONS-SC+-10G-LR)

  • DWDM(ONS-SC+-10G-C)

  • DWDM(ONS-SC+-10GEPxx.x)

  • ER (ONS-SC+-10G-ER)

  • ZR (ONS-SC+-10G-ZR)

  • DWDM(ONS-SC+-10G-xx.x)

No No Auto
100G - CK- LC-C + 10x10G-LC
  • 10GE

  • 10GE LAN PHY

  • OC192

  • Fiber Channel 10G

  • Fiber Channel 8G

  • OTU2

  • OTU2e

FEC
  • SR-1(ONS-SC+-10G-SR)

  • LR-1(ONS-SC+-10G-LR)

  • DWDM(ONS-SC+-10G-C)

  • DWDM(ONS-SC+-10GEPxx.x)

  • ER(ONS-SC+-10G-ER)

  • ZR(ONS-SC+-10G-ZR)

  • DWDM(ONS-SC+-10G-xx.x)

No No Auto
100G -CK-LC-C + 10x10G-LC
  • 10GE

  • 10GE LAN PHY

  • OC192

  • Fiber Channel 10G

  • Fiber Channel 8G

  • OTU2

  • OTU2e

EFEC
  • SR-1(ONS-SC+-10G-SR)

  • LR-1(ONS-SC+-10G-LR)

  • DWDM(ONS-SC+-10G-C)

  • DWDM(ONS-SC+-10GEPxx.x)

  • ER(ONS-SC+-10G-ER)

  • ZR(ONS-SC+-10G-ZR)

  • DWDM(ONS-SC+-10G-xx.x)

No No Auto
100G - CK-LC-C + 10x10G-LC
  • 10GE

  • 10GE LAN PHY

  • OC192

  • Fiber Channel 10G

  • Fiber Channel 8G

  • OTU2

  • OTU2e

HG-FEC
  • SR-1(ONS-SC+-10G-SR)

  • LR-1(ONS-SC+-10G-LR)

  • DWDM(ONS-SC+-10G-C)

  • DWDM(ONS-SC+-10GEPxx.x)

  • ER(ONS-SC+-10G-ER)

  • ZR(ONS-SC+-10G-ZR)

  • DWDM(ONS-SC+-10G-xx.x)

No No Auto
400G-XP-LC
  • 100GE

  • 10GE LAN PHY

  • 10GE

  • 40GE

  • Fiber Channel 10G

  • Fiber Channel 16G

  • Fiber Channel 8G

  • OC192 /STM64

  • OTU2

  • OTU2e

  • OTU4

SD-FEC_25- NO_DE
  • SR-1(QSFP-100G-SR4-S)

  • LR-1(QSFP-100G-LR4-S)

  • LR-1(QSFP-28-LR4)

  • SR-1(QSFP-100G-SM-SR)

  • SR-1(QSFP-40/100G-SRBD)

  • LR-1(ONS-QSFP-4*10G-MLR)

  • LR-1(QSFP-4*10G-LR)

  • SR-1(QSFP-40G-SR4)

  • ER(ONS-QSFP-4*10G-MER)

  • LR-1(QSFP-40G-LR4)

    SR-1(QSFP-40G-SR-BD

  • LR-1(ONS-QC16GFC-LW)

  • LR-1(ONS-QC16GFC-SW)

  • LR-1(ONS-QSFP28-LR4)

  • FR-1 (QSFP-100G-FR-S) (only for 100GE)

  • ER-1 (QSFP-100G-ERL-S) (only for 100GE)

Yes Yes TRK_100G, TRK_200G
400G-XP-LC
  • 100GE

  • 10GE LAN PHY

  • 10GE

  • 40GE

  • Fiber Channel 10G

  • Fiber Channel 16G

  • Fiber Channel 8G

  • OC192 /STM64

  • OTU2

  • OTU2e

  • OTU4

SD-FEC_15 -NO_DE
  • SR-1(QSFP-100G-SR4-S)

  • LR-1(QSFP-100G-LR4-S)

  • LR-1(QSFP-28-LR4)

  • SR-1(QSFP-100G-SM-SR)

  • SR-1 (QSFP-40/100G-SRBD)

  • LR-1(ONS-QSFP-4*10G-MLR)

  • LR-1(QSFP-4*10G-LR)

  • SR-1(QSFP-40G-SR4)

  • ER(ONS-QSFP-4*10G-MER)

  • LR-1(QSFP-40G-LR4)

  • SR-1(QSFP-40G-SR-BD

  • LR-1(ONS-QC16GFC-LW)

  • LR-1(ONS-QC16GFC-SW)

  • LR-1(ONS-QSFP28-LR4)

  • FR-1 (QSFP-100G-FR-S) (only for 100GE)

  • LR-1 (QSFP-100G-ERL-S) (only for 100GE)

Yes Yes TRK_100G, TRK_200G
100G-LC-C
  • 100GE

  • OTU4

FEC SR-1(CPAK-100G-SR10) No No Auto
100G-LC-C
  • 100GE

  • OTU4

EFEC SR-1(CPAK-100G-SR10) No No Auto
100G-LC-C
  • 100GE

  • OTU4

HGFEC SR-1(CPAK-100G-SR10) No No Auto
100G - CK-LC-C
  • 100GE

  • 40GE

  • OTU4

FEC
  • SR-1(CPAK-100G-SR4)

  • SR-1(CPAK-100G-SR10)

  • LR-1(CPAK-100G-LR4)

No No Auto
100G - CK-LC-C
  • 100GE

  • 40GE

  • OTU4

EFEC
  • SR-1(CPAK-100G-SR4)

  • SR-1(CPAK-100G-SR10)

  • LR-1(CPAK-100G-LR4)

No No Auto
100G - CK-LC-C
  • 100GE

  • 40GE

  • OTU4

HGFEC
  • SR-1(CPAK-100G-SR4)

  • SR-1(CPAK-100G-SR10)

  • LR-1(CPAK-100G-LR4)

No No Auto
100GS - CK-LC 100GE FEC SR-1(CPAK-100G-SR10) Yes No

Auto, TRK_100G

100GS - CK-LC 100GE EFEC LR-1(CPAK-100G-LR4) YEs No

Auto, TRK_100G

100GS - CK-LC 100GE SD-FEC_20 SR-1(CPAK-100G-SR10) Yes No

Auto, TRK_100G

200G - CK-LC (100G Mode only)
  • 100GE

  • OTU4

FEC
  • SR-1(CPAK-100G-SR4)

  • SR-1(CPAK-100G-SR10)

  • LR-1(CPAK-100G-LR4)

Yes (for 100GE) No

Auto, TRK_100G

200G - CK-LC (100G Mode only)
  • 100GE

  • OTU4

EFEC
  • SR-1(CPAK-100G-SR4)

  • SR-1(CPAK-100G-SR10)

  • LR-1(CPAK-100G-LR4)

Yes (for 100GE) No

Auto, TRK_100G

200G-CK-LC (100G Mode only)
  • 100GE

  • OTU4

SD-FEC_20
  • SR-1(CPAK-100G-SR4)

  • SR-1(CPAK-100G-SR10)

  • LR-1(CPAK-100G-LR4)

Yes (for 100GE) No

Auto, TRK_100G

Cisco ONP supports the following transponders and pluggables for NCS 2000 networks:

Table 3. Supported Transponder Cards and Pluggables for NCS 1010 Network

Transponder / Muxponder

Traffic Type

FEC mode

Pluggables Supported

Encryption

Trunk Mode

NCS1K14-2.4T-K9

100GE

400GE

SD_FEC_15

Client Pluggables:

  • Auto

  • QDD-400G-FR4-S

  • QDD-400-AOC1M

  • QDD-400G-DR4-S

  • QDD-4x100G-LR-S

Trunk Pluggables:

  • Auto

  • CIM-C-K9

No

  • Auto

  • 400G

  • 500G

  • 600G

  • 700G

  • 800G

  • 900G

  • 1000G

  • 1100G

  • 1200G

NCS1K14-2.4T-x-K9

100GE

400GE

SD_FEC_15

Client Pluggables:

  • Auto

  • QDD-400G-FR4-S

  • QDD-400-AOC1M

  • QDD-400G-DR4-S

  • QDD-400G-LR4-S

  • QDD-4x100G-LR-S

  • QDD-4x100G-FR-S

Trunk Pluggables:

  • Auto

  • CIM-C-K9

Yes

  • Auto

  • 400G

  • 500G

  • 600G

  • 700G

  • 800G

  • 900G

  • 1000G

  • 1100G

  • 1200G

NCS1K4-QXP-K9

100GE

400GE

OFEC

CFEC

Client Pluggables:

  • Auto

  • QDD-400G-FR4-S

  • QDD-400-AOC1M

  • QDD-400G-DR4-S

  • QDD-4x100G-LR-S

  • QSFP-100G-DR-S

  • QSFP-100G-LR4-S

  • QSFP-100G-LR-S

  • ONS-QSFP-28-LR4

  • QSFP-100G-CWDM4-S

  • QSFP-100G-FR-S

  • QSFP-100G-SR4-S

Trunk Pluggables:

  • Auto

  • QDD-400G-ZRP-S

  • QDD-400G-ZR-S

Yes

  • Auto

  • 100G

  • 200G

  • 300G

  • 400G