Monitor Performance
You can set and retrieve PM counters for the OTS, OTS-OCH, OSC, DFB, OCH, and OMS controllers for various intervals.
The OCH and OMS controllers are created when the Mux/Demux panel and breakout panels are powered up using the USB 2.0 connection from the NCS 1010 EITU card. You can only view the current and historical PM parameters for the panels. You cannot configure the PM parameters for these controllers.
This table lists the PM parameters, their descriptions, and precision levels.
PM Parameter (Unit of Measure) |
Description |
Resolution |
OPT [dBM] |
Total Tx(C+OSC) power |
1/100 |
OPR [dBM] |
Total Rx(C+OSC) power |
1/100 |
OPT(C+L) [dBM] |
Total Tx(C+L+OSC) power |
1/100 |
OPR(C+L) [dBM] |
Total Rx(C+L+OSC) power |
1/100 |
OPR(S) [dBM] |
C Band Received Signal Power |
1/100 |
OPT(S) [dBM] |
C Band Transmitted Signal Power |
1/100 |
OPBR [dBM] |
Back Reflection Power |
1/100 |
EAGN [dB] |
Egress Amplifier Gain |
1/100 |
EATL [dB] |
Egress Amplifier Tilt |
1/100 |
IAGN [dB] |
Ingress Amplifier Gain |
1/100 |
IATL [dB] |
Ingress Amplifier Tilt |
1/100 |
RAMAN-TOT [mW] |
Raman Total Pump power |
1/10 |
RAMAN-1 [mW] |
Raman 1 Pump power |
1/10 |
RAMAN-2 [mW] |
Raman 2 Pump power |
1/10 |
RAMAN-3 [mW] |
Raman 3 Pump power |
1/10 |
RAMAN-4 [mW] |
Raman 4 Pump power |
1/10 |
RAMAN-5 [mW] |
Raman 5 Pump power |
1/10 |
The following tables list the maximum and minimum thresholds that can be set for the PM parameters for OLT nodes
PM Parameter |
Minimum Threshold |
Maximum Threshold |
OPT |
–2000 |
4000 |
OPR |
–3000 |
1800 |
OPT(C+L) |
–2000 |
6085 |
OPR(C+L) |
–3000 |
3600 |
OPR(S) |
–3000 |
1800 |
OPT(S) |
–500 |
2800 |
OPBR |
–3000 |
–1400 |
EAGN |
1390 |
3100 |
EATL |
–500 |
500 |
IAGN |
1030 |
3800 |
IATL |
–500 |
500 |
RAMAN-TOT |
2000 |
14100 |
RAMAN-1 |
450 |
3900 |
RAMAN-2 |
400 |
3900 |
RAMAN-3 |
400 |
2200 |
RAMAN-4 |
400 |
2200 |
RAMAN-5 |
350 |
1900 |
PM Parameter |
Minimum Threshold |
Maximum Threshold |
OPT |
–3000 |
1500 |
OPR |
–2500 |
1800 |
IAGN |
1300 |
1900 |
IATL |
–500 |
500 |
PM Parameter |
Minimum Threshold |
Maximum Threshold |
OPT |
–3000 |
1500 |
OPR |
–1500 |
1000 |
PM Parameter |
Minimum Threshold |
Maximum Threshold |
OPT |
–3000 |
1500 |
OPR |
–3000 |
1500 |
Parameter |
Threshold Min |
Threshold Max |
OPT |
–2000 |
1200 |
OPR |
–3000 |
0 |
PM Parameter |
Minimum Threshold |
MaximumThreshold |
OPT |
–2000 |
1000 |
OPR |
–3000 |
1500 |
The following tables list the maximum and minimum thresholds that can be set for the PM parameters for ILA nodes.
PM Parameter |
Minimum Threshold |
Maximum Threshold |
OPT |
–3000 |
4000 |
OPR |
–3000 |
2000 |
OPT(C+L) |
–3000 |
6085 |
OPR(C+L) |
–3000 |
4000 |
OPR(S) |
–3000 |
2800 |
OPT(S) |
–3000 |
2000 |
OPBR |
–3000 |
–1400 |
EAGN |
590 |
3600 |
EATL |
–500 |
500 |
RAMAN-TOT |
2000 |
14100 |
RAMAN-1 |
450 |
3900 |
RAMAN-2 |
400 |
3900 |
RAMAN-3 |
400 |
2200 |
RAMAN-4 |
400 |
2200 |
RAMAN-5 |
350 |
1900 |
PM Parameter |
Minimum Threshold |
Maximum Threshold |
OPT |
–3000 |
4000 |
OPR |
–3000 |
2000 |
OPT(C+L) |
–3000 |
6085 |
OPR(C+L) |
–3000 |
4000 |
OPR(S) |
–3000 |
2800 |
OPT(S) |
–3000 |
2000 |
OPBR |
–3000 |
–1400 |
EAGN |
590 |
3600 |
EATL |
–500 |
500 |
RAMAN-TOT |
2000 |
14100 |
RAMAN-1 |
450 |
3900 |
RAMAN-2 |
400 |
3900 |
RAMAN-3 |
400 |
2200 |
RAMAN-4 |
400 |
2200 |
RAMAN-5 |
350 |
1900 |
PM Parameter |
Minimum Threshold |
Maximum Threshold |
OPT |
–2000 |
1200 |
OPR |
–3000 |
0 |
PM Parameter |
Minimum Threshold |
Maximum Threshold |
OPT |
–3000 |
1500 |
OPR |
–3000 |
1500 |
PM Parameter |
Minimum Threshold |
Maximum Threshold |
OPT |
–2000 |
1000 |
OPR |
–3000 |
1500 |
This table lists the maximum and minimum thresholds that are set for the PM parameters for OCH controllers.
PM Parameter |
Minimum Threshold |
Maximum Threshold |
---|---|---|
OPT |
–30 |
15 |
OPR |
–30 |
15 |
This table lists the maximum and minimum thresholds that are set for the PM parameters for OMS controllers.
PM Parameter |
Minimum Threshold |
Maximum Threshold |
---|---|---|
OPT |
–30 |
15 |
OPR |
–30 |
15 |