Monitor Performance
You can set and retrieve PM counters for the OTS, OTS-OCH, OSC, OCH, and OMS controllers for various intervals.
PM Parameters for Controllers table lists the PM parameters, their descriptions, and precision levels.
PM Parameter (Unit of Measure) |
Description |
Resolution |
SLR(C+L) [dB] |
Rx Span Loss |
1/100 |
SLT(C+L) [dB] |
Tx Span Loss |
1/100 |
SLR(S) [dB] |
Rx Signal Span Loss |
1/100 |
SLT(S) [dB] |
Tx Signal Span Loss |
1/100 |
OPT [dBM] |
Total Tx(C+OSC) power |
1/100 |
OPR [dBM] |
Total Rx(C+OSC) power |
1/100 |
OPT(C+L) [dBM] |
Total Tx(C+L+OSC) power |
1/100 |
OPR(C+L) [dBM] |
Total Rx(C+L+OSC) power |
1/100 |
OPR(S) [dBM] |
C Band Received Signal Power |
1/100 |
OPT(S) [dBM] |
C Band Transmitted Signal Power |
1/100 |
OPBR [dBM] |
Back Reflection Power |
1/100 |
EAGN [dB] |
Egress Amplifier Gain |
1/100 |
EATL [dB] |
Egress Amplifier Tilt |
1/100 |
IAGN [dB] |
Ingress Amplifier Gain |
1/100 |
IATL [dB] |
Ingress Amplifier Tilt |
1/100 |
The PM Thresholds for OLT OTS Controller tables list the maximum and minimum thresholds that can be set for the PM parameters for OLT nodes.
PM Parameter |
Minimum Threshold |
Maximum Threshold |
OPT |
–2000 |
4000 |
OPR |
–3000 |
1800 |
OPT(C+L) |
–2000 |
6085 |
OPR(C+L) |
–3000 |
3600 |
OPR(S) |
–3000 |
1800 |
OPT(S) |
–500 |
2800 |
OPBR |
–3000 |
–1400 |
EAGN |
1390 |
3100 |
EATL |
–500 |
500 |
IAGN |
1030 |
3800 |
IATL |
–500 |
500 |
PM Parameter |
Minimum Threshold |
Maximum Threshold |
OPT |
–3000 |
1500 |
OPR |
–2500 |
1800 |
IAGN |
1300 |
1900 |
IATL |
–500 |
500 |
PM Parameter |
Minimum Threshold |
Maximum Threshold |
OPT |
–3000 |
1500 |
OPR |
–1500 |
1000 |
PM Parameter |
Minimum Threshold |
Maximum Threshold |
OPT |
–3000 |
1500 |
OPR |
–3000 |
1500 |
Parameter |
Threshold Min |
Threshold Max |
OPT |
–2000 |
1200 |
OPR |
–3000 |
0 |
PM Thresholds for OCH Controllers table lists the maximum and minimum thresholds that are set for the PM parameters for OCH controllers.
PM Parameter |
Minimum Threshold |
Maximum Threshold |
---|---|---|
OPT |
–30 |
15 |
OPR |
–30 |
15 |
PM Thresholds for OMS Controllers table lists the maximum and minimum thresholds that are set for the PM parameters for OMS controllers.
PM Parameter |
Minimum Threshold |
Maximum Threshold |
---|---|---|
OPT |
–30 |
15 |
OPR |
–30 |
15 |