Pinouts
The following sections describe the pinouts for the Cisco ASR 920 Series Router interfaces:
Alarm Port Pinouts
Table below summarizes the external alarm input pinouts.
Pin |
Signal Name |
Description |
---|---|---|
1 |
ALARM0_IN |
Alarm input 0 |
2 |
ALARM1_IN |
Alarm input 1 |
3 |
— |
No connect |
4 |
ALARM2_IN |
Alarm input 2 |
5 |
ALARM3_IN |
Alarm input 3 |
6 |
— |
No connect |
7 |
— |
No connect |
8 |
COMMON |
Alarm common |
Management Ethernet Port Pinouts
Table below summarizes the Management Ethernet port pinouts.
Pin |
Signal Name |
---|---|
1 |
TRP0+ |
2 |
TRP0- |
3 |
TRP1+ |
4 |
TRP2+ |
5 |
TRP2- |
6 |
TRP1- |
7 |
TRP3+ |
8 |
TRP3- |
USB Console Port Pinouts
Table below summarizes the USB console port pinouts.
Pin |
Signal Name |
Description |
---|---|---|
A1 |
Vcc |
+5VDC |
A2 |
D- |
Data - |
A3 |
D+ |
Data + |
A4 |
Gnd |
Ground |
Note |
The USB console port +5VDC is input, and operates as an USB peripheral device. |
USB MEM Port Pinouts
Table below summarizes the USB MEM port pinouts.
Pin |
Signal Name |
Description |
---|---|---|
A1 |
Vcc |
+5VDC (500mA) |
A2 |
D- |
Data - |
A3 |
D+ |
Data + |
A4 |
Gnd |
Ground |
Note |
USB TYPE-A receptacle is used. |
Note |
The USB MEM port +5VDC is output. Cisco ASR 920 Series Aggregation Services Router provides power for USB MEM port. This port operates as a USB host device. |
Optical Fiber Specifications
The specification for optical fiber transmission defines two types of fiber: single mode and multimode. Within the single-mode category, three transmission types are defined: short reach, intermediate reach, and long reach. Within the multimode category, only short reach is available. For information about optical SFP modules, see the documentation for the SFP module at:
http://www.cisco.com/en/US/partner/products/hw/modules/ps5455/prod_installation_guides_list.html .
Alarm Conditions
Table below summarizes the meaning of the alarm conditions on the Cisco ASR 920 Series Router.
Alarm Type |
Alarm Meaning |
---|---|
Critical |
Port in down state or only single power supply operational Environmental sensor threshold exceeded critical level (voltage, temperature) |
Major |
Environmental sensor threshold exceeded major level (voltage, temperature) |
Info |
Port administratively shut down. |