Overview of the OCx Interface Module

The features of the following OCx interface modules are configured based on the SONET and SDH mode support:
  • 1-port OC-48/STM-16 or 4-port OC-12/OC-3 / STM-1/STM-4 + 12-port T1/E1 + 4-port T3/E3 CEM Interface ModuleNCS4200-3GMS

  • 1-Port OC-192 or 8-Port Low Rate CEM Interface Module NCS4200-1T8S-10CS

  • NCS 4200 1-Port OC-192 or 8-Port Low Rate CEM 20G Bandwidth Interface Module (NCS4200-1T8S-20CS)

SONET Modes

SONET supports the following Circuit Emulation over Packet (CEP), Structure- Agnostic TDM over Packet (SATOP), and Circuit Emulation over Packet-Switched Network (CESoPSN) modes:

CEP Modes

  • STS-48C

  • STS-12C

  • STS-3C

  • STS-1

  • VT 1.5

SAToP or CESoP

  • VT1.5-T1

  • T3

  • CT3-T1

The following table provides required clock and CEM configuration that is supported on each of the SONET mode:

Table 1. Modes Supported on SONET

STS-48C

STS-12C

STS-3C

STS-1

VT 1.5

VT 1.5 T1

T3

CT3-T1

Required Configuration

Mode

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Internal/Line Clock Source

Internal

Internal

Internal

Internal

Internal

Yes

Yes

Yes

ACR/DCR Clock

NA

NA

NA

NA

NA

Yes

Yes

Yes

CEM Configurations

CEP

Yes

Yes

Yes

Yes

Yes

NA

Yes

NA

SAToP Framed

NA

NA

NA

NA

NA

Yes

Yes

Yes

SAToP Unframed

NA

NA

NA

NA

NA

Yes

Yes

Yes

CESoPSN

NA

NA

NA

NA

NA

Yes

Yes

Yes

Interworking Multiservice Gateway (iMSG)

1

iMSG

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Serial Interfaces

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

iMSG ACR

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Multilink Interfaces

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

VLAN Handoff

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

OCx Port Protection

APS

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

OCx Path Protection

UPSR

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

UPSR over HDLC

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

1 Supports Channelized T3/E3or T1/E1

SDH Modes

SDH supports the following modes:

  • AU-4-16c (VC4-16c)

  • AU-4-4c (VC4-4c)

  • AU-4 (VC4)

  • AU-4 — TUG-3 — VC-3 — T3 (TUG-3 — T3)

  • AU-4 — TUG-3 — VC-3 — E3 (TUG-3 — E3)

  • AU-4 — TUG-3 — TUG-2 — VC-11 (TUG-2 — VC-11)

  • AU-4 — TUG-3 — TUG-2 — VC-12 (TUG-2 — VC-12)

  • AU-4 — TUG-3 — TUG-2 — VC-12 — E1 (TUG-2 — E1)

  • AU-3 — VC-3 — T3 (VC-3 — T3)

  • AU-3 — TUG-2 — VC-11 — T1 (TUG-2 — T1)

  • AU-3 — TUG-2 — VC-11 (TUG-2 — VC-11)

  • AU-3 — TUG-2 — VC-12 (TUG-2 — VC-12)

  • AU-3 — VC-3 — E3 (VC-3 — T3)

The following table provides required clock and CEM configuration that is supported on each of the SDH mode. The SDH modes provided in brackets are only for the documentation purpose:

Table 2. Modes Supported on SDH

VC4-16c

VC4-4c

VC4

TUG-2-VC11

TUG-2-VC12

TUG-3-E3

TUG-3-T3

TUG-2-VC11-T1

TUG-2-VC12-E1

Required Configuration

Mode

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Internal/Line Clock Source

Internal

Internal

Internal

Internal

Internal

Yes

Yes

Yes

Yes

ACR/DCR Clock

NA

NA

NA

NA

NA

Yes

Yes

Yes

Yes

CEM Configurations

CEP

Yes

Yes

Yes

Yes

Yes

NA

NA

NA

NA

SAToP Framed

NA

NA

NA

NA

NA

Yes

Yes

Yes

Yes

SAToP Unframed

NA

NA

NA

NA

NA

Yes

Yes

Yes

Yes

CESoPSN

NA

NA

NA

NA

NA

Yes

Yes

Yes

Yes

Interworking Multiservice Gateway (iMSG)

iMSG

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Serial Interfaces

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

iMSG ACR

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

OCx Port Protection

MSP

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

OCx Path Protection

SNCP

Yes

Yes

Yes

Yes

Yes

NA

NA

NA

NA