fltFabricComputeSlotEpMisplacedInChassisSlot
Fault Code: F0156
Message
Server, vendor([vendor]), model([model]), serial([serial]) in slot [chassisId]/[slotId] presence: [presence]
Explanation
This fault typically occurs when Cisco FPR Manager detects a server in a chassis slot that does not match what was previously equipped in the slot.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the previous server was intentionally removed and a new one was inserted, reacknowledge the server.
Step 2 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFabricComputeSlotEpMisplacedInChassisSlot
moClass: fabric:ComputeSlotEp
Affected MO: fabric/server/chassis-[chassisId]/slot-[slotId]
fltFabricComputeSlotEpServerIdentificationProblem
Fault Code: F0157
Message
Problem identifying server in slot [chassisId]/[slotId]
Explanation
This fault typically occurs when Cisco FPR Manager encountered a problem identifying the server in a chassis slot.
Recommended Action
If you see this fault, take the following actions:
Step 1 Remove and reinsert the server.
Step 2 Reacknowledge the server.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: server-identification-problem
mibFaultName: fltFabricComputeSlotEpServerIdentificationProblem
moClass: fabric:ComputeSlotEp
Affected MO: fabric/server/chassis-[chassisId]/slot-[slotId]
fltVnicEtherConfig-failed
Fault Code: F0169
Message
Eth vNIC [name], service profile [name] failed to apply configuration
Explanation
This fault typically occurs when Cisco FPR Manager could not place the vNIC on the vCon.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the server was successfully discovered.
Step 2 Verify that the correct type of adapters are installed on the server.
Step 3 Confirm that the vCon assignment is correct.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: configuration-failed
mibFaultName: fltVnicEtherConfigFailed
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]
fltProcessorUnitInoperable
Fault Code: F0174
Message
Processor [id] on server [chassisId]/[slotId] operability: [operability]
Explanation
This fault occurs in the unlikely event that processor is inoperable.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the fault occurs on a blade server processor, remove the server from the chassis and then reinsert it.
Step 2 In Cisco FPR Manager, decommission and then recommission the server.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inoperable
mibFaultName: fltProcessorUnitInoperable
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]
Affected MO: sys/rack-unit-[id]/board/cpu-[id]
fltProcessorUnitThermalNonCritical
Fault Code: F0175
Message
Processor [id] on server [chassisId]/[slotId] temperature: [thermal]Processor [id] on server [id] temperature: [thermal]
Explanation
This fault occurs when the processor temperature on a blade or rack server exceeds a non-critical threshold value, but is still below the critical threshold. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
- If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the server.
Step 2 Review the Cisco FPR Site Preparation Guide to ensure the servers have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco FPR chassis or rack server are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 8 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltProcessorUnitThermalNonCritical
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]
Affected MO: sys/rack-unit-[id]/board/cpu-[id]
fltProcessorUnitThermalThresholdCritical
Fault Code: F0176
Message
Processor [id] on server [chassisId]/[slotId] temperature: [thermal]Processor [id] on server [id] temperature: [thermal]
Explanation
This fault occurs when the processor temperature on a blade or rack server exceeds a critical threshold value. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
- If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the server.
Step 2 Review the Cisco FPR Site Preparation Guide to ensure the servers have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco FPR chassis or rack server are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 8 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltProcessorUnitThermalThresholdCritical
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]
Affected MO: sys/rack-unit-[id]/board/cpu-[id]
fltProcessorUnitThermalThresholdNonRecoverable
Fault Code: F0177
Message
Processor [id] on server [chassisId]/[slotId] temperature: [thermal]Processor [id] on server [id] temperature: [thermal]
Explanation
This fault occurs when the processor temperature on a blade or rack server has been out of the operating range, and the issue is not recoverable. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
- If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the server.
Step 2 Review the Cisco FPR Site Preparation Guide to ensure the servers have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco FPR chassis or rack server are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 8 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltProcessorUnitThermalThresholdNonRecoverable
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]
Affected MO: sys/rack-unit-[id]/board/cpu-[id]
fltProcessorUnitVoltageThresholdNonCritical
Fault Code: F0178
Message
Processor [id] on server [chassisId]/[slotId] voltage: [voltage]Processor [id] on server [id] voltage: [voltage]
Explanation
This fault occurs when the processor voltage is out of normal operating range, but hasn’t yet reached a critical stage. Normally the processor recovers itself from this situation
Recommended Action
If you see this fault, take the following actions:
Step 1 Monitor the processor for further degradation.
Step 2 If the fault occurs on a blade server processor, remove the server from the chassis and then reinsert it.
Step 3 In Cisco FPR Manager, decommission and then recommission the server.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltProcessorUnitVoltageThresholdNonCritical
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]
Affected MO: sys/rack-unit-[id]/board/cpu-[id]
fltProcessorUnitVoltageThresholdCritical
Fault Code: F0179
Message
Processor [id] on server [chassisId]/[slotId] voltage: [voltage]Processor [id] on server [id] voltage: [voltage]
Explanation
This fault occurs when the processor voltage has exceeded the specified hardware voltage rating.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the fault occurs on a blade server processor, remove the server from the chassis and then reinsert it.
Step 2 In Cisco FPR Manager, decommission and then recommission the server.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltProcessorUnitVoltageThresholdCritical
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]
Affected MO: sys/rack-unit-[id]/board/cpu-[id]
fltProcessorUnitVoltageThresholdNonRecoverable
Fault Code: F0180
Message
Processor [id] on server [chassisId]/[slotId] voltage: [voltage]Processor [id] on server [id] voltage: [voltage]
Explanation
This fault occurs when the processor voltage has exceeded the specified hardware voltage rating and may cause processor hardware damage or jeopardy.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the fault occurs on a blade server processor, remove the server from the chassis and then reinsert it.
Step 2 In Cisco FPR Manager, decommission and then recommission the server.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltProcessorUnitVoltageThresholdNonRecoverable
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]
Affected MO: sys/rack-unit-[id]/board/cpu-[id]
fltStorageLocalDiskInoperable
Fault Code: F0181
Message
Local disk [id] on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]Local disk [id] on server [id] operability: [operability]. Reason: [operQualifierReason]
Explanation
This fault occurs when the local disk has become inoperable.
Recommended Action
If you see this fault, take the following actions:
Step 1 Insert the disk in a supported slot.
Step 2 Remove and reinsert the local disk.
Step 3 Replace the disk, if an additional disk is available.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inoperable
mibFaultName: fltStorageLocalDiskInoperable
moClass: storage:LocalDisk
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]
fltStorageItemCapacityExceeded
Fault Code: F0182
Message
Disk usage for partition [name] on fabric interconnect [id] exceeded 70%
Explanation
This fault occurs when the partition disk usage exceeds 70% but is less than 90%.
Recommended Action
If you see this fault, take the following actions:
Step 1 Reduce the partition disk usage to less than 70% by deleting unused and unnecessary files.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltStorageItemCapacityExceeded
Affected MO: sys/switch-[id]/stor-part-[name]
fltStorageItemCapacityWarning
Fault Code: F0183
Message
Disk usage for partition [name] on fabric interconnect [id] exceeded 90%
Explanation
This fault occurs when the partition disk usage exceeds 90%.
Recommended Action
If you see this fault, take the following actions:
Step 1 Reduce the partition disk usage to less than 90% by deleting unused and unnecessary files.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltStorageItemCapacityWarning
Affected MO: sys/switch-[id]/stor-part-[name]
fltMemoryUnitDegraded
Fault Code: F0184
Message
DIMM [location] on server [chassisId]/[slotId] operability: [operability]DIMM [location] on server [id] operability: [operability]
Explanation
This fault occurs when a DIMM is in a degraded operability state. This state typically occurs when an excessive number of correctable ECC errors are reported on the DIMM by the server BIOS.
Recommended Action
If you see this fault, take the following actions:
Step 1 Monitor the error statistics on the degraded DIMM through Cisco FPR Manager. If the high number of errors persists, there is a high possibility of the DIMM becoming inoperable.
Step 2 If the DIMM becomes inoperable, replace the DIMM.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-degraded
mibFaultName: fltMemoryUnitDegraded
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]/mem-[id]
Affected MO: sys/rack-unit-[id]/board/memarray-[id]/mem-[id]
fltMemoryUnitInoperable
Fault Code: F0185
Message
DIMM [location] on server [chassisId]/[slotId] operability: [operability]DIMM [location] on server [id] operability: [operability]
Explanation
This fault typically occurs because an above threshold number of correctable or uncorrectable errors has occurred on a DIMM. The DIMM may be inoperable.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the SEL is enabled, review the SEL statistics on the DIMM to determine which threshold was crossed.
Step 2 If necessary, replace the DIMM.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inoperable
mibFaultName: fltMemoryUnitInoperable
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]/mem-[id]
Affected MO: sys/rack-unit-[id]/board/memarray-[id]/mem-[id]
fltMemoryUnitThermalThresholdNonCritical
Fault Code: F0186
Message
DIMM [location] on server [chassisId]/[slotId] temperature: [thermal]DIMM [location] on server [id] temperature: [thermal]
Explanation
This fault occurs when the temperature of a memory unit on a blade or rack server exceeds a non-critical threshold value, but is still below the critical threshold. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
- If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the server.
Step 2 Review the Cisco FPR Site Preparation Guide to ensure the servers have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco FPR chassis or rack server are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 8 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltMemoryUnitThermalThresholdNonCritical
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]/mem-[id]
Affected MO: sys/rack-unit-[id]/board/memarray-[id]/mem-[id]
fltMemoryUnitThermalThresholdCritical
Fault Code: F0187
Message
DIMM [location] on server [chassisId]/[slotId] temperature: [thermal]DIMM [location] on server [id] temperature: [thermal]
Explanation
This fault occurs when the temperature of a memory unit on a blade or rack server exceeds a critical threshold value. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
- If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the server.
Step 2 Review the Cisco FPR Site Preparation Guide to ensure the servers have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco FPR chassis or rack server are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 8 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltMemoryUnitThermalThresholdCritical
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]/mem-[id]
Affected MO: sys/rack-unit-[id]/board/memarray-[id]/mem-[id]
fltMemoryUnitThermalThresholdNonRecoverable
Fault Code: F0188
Message
DIMM [location] on server [chassisId]/[slotId] temperature: [thermal]DIMM [location] on server [id] temperature: [thermal]
Explanation
This fault occurs when the temperature of a memory unit on a blade or rack server has been out of the operating range, and the issue is not recoverable.Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
- If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the server.
Step 2 Review the Cisco FPR Site Preparation Guide to ensure the servers have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco FPR chassis or rack server are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 8 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltMemoryUnitThermalThresholdNonRecoverable
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]/mem-[id]
Affected MO: sys/rack-unit-[id]/board/memarray-[id]/mem-[id]
fltMemoryArrayVoltageThresholdNonCritical
Fault Code: F0189
Message
Memory array [id] on server [chassisId]/[slotId] voltage: [voltage]Memory array [id] on server [id] voltage: [voltage]
Explanation
This fault occurs when the memory array voltage is out of normal operating range, but hasn’t yet reached a critical stage. Typically the memory array recovers itself from this situation.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the SEL is enabled, look at the SEL statistics on the DIMM to determine which threshold was crossed.
Step 2 Monitor the memory array for further degradation.
Step 3 If the fault occurs on a blade server memory array, remove the blade and re-insert into the chassis.
Step 4 In Cisco FPR Manager, decommission and recommission the server.
Step 5 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltMemoryArrayVoltageThresholdNonCritical
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]
Affected MO: sys/rack-unit-[id]/board/memarray-[id]
fltMemoryArrayVoltageThresholdCritical
Fault Code: F0190
Message
Memory array [id] on server [chassisId]/[slotId] voltage: [voltage]Memory array [id] on server [id] voltage: [voltage]
Explanation
This fault occurs when the memory array voltage exceeds the specified hardware voltage rating
Recommended Action
If you see this fault, take the following actions:
Step 1 If the SEL is enabled, look at the SEL statistics on the DIMM to determine which threshold was crossed.
Step 2 Monitor the memory array for further degradation.
Step 3 If the fault occurs on a blade server memory array, remove the blade and re-insert into the chassis.
Step 4 In Cisco FPR Manager, decommission and recommission the server.
Step 5 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltMemoryArrayVoltageThresholdCritical
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]
Affected MO: sys/rack-unit-[id]/board/memarray-[id]
fltMemoryArrayVoltageThresholdNonRecoverable
Fault Code: F0191
Message
Memory array [id] on server [chassisId]/[slotId] voltage: [voltage]Memory array [id] on server [id] voltage: [voltage]
Explanation
This fault occurs when the memory array voltage exceeded the specified hardware voltage rating and potentially memory hardware may be in damage or jeopardy
Recommended Action
If you see this fault, take the following actions:
Step 1 If the SEL is enabled, review the SEL statistics on the DIMM to determine which threshold was crossed.
Step 2 Monitor the memory array for further degradation.
Step 3 If the fault occurs on a blade server memory array, remove the server from the chassis and re-insert it.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltMemoryArrayVoltageThresholdNonRecoverable
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]
Affected MO: sys/rack-unit-[id]/board/memarray-[id]
fltAdaptorUnitUnidentifiable-fru
Fault Code: F0200
Message
Adapter [id] in server [id] has unidentified FRUAdapter [id] in server [chassisId]/[slotId] has unidentified FRU
Explanation
This fault typically occurs because Cisco FPR Manager has detected an unsupported adapter. For example, the model, vendor, or revision is not recognized.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that a supported adapter is installed.
Step 2 Verify that the capability catalog in Cisco FPR Manager is up to date. If necessary, update the catalog.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: unidentifiable-fru
mibFaultName: fltAdaptorUnitUnidentifiableFru
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]
fltAdaptorUnitMissing
Fault Code: F0203
Message
Adapter [id] in server [id] presence: [presence]Adapter [id] in server [chassisId]/[slotId] presence: [presence]
Explanation
The adaptor is missing. Cisco FPR Manager raises this fault when any of the following scenarios occur:
- The endpoint reports there is no adapter in the adaptor slot.
- The endpoint cannot detect or communicate with the adapter in the adaptor slot.
Recommended Action
If you see this fault, take the following actions:
Step 1 Make sure an adapter is inserted in the adaptor slot in the server.
Step 2 Check whether the adaptor is connected and configured properly and is running the recommended firmware version.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltAdaptorUnitMissing
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]
fltAdaptorUnitAdaptorReachability
Fault Code: F0206
Message
Adapter [id]/[id] is unreachableAdapter [chassisId]/[slotId]/[id] is unreachable
Explanation
Cisco FPR Manager cannot access the adapter. This fault typically occurs as a result of one of the following issues:
- The server does not have sufficient power.
- The I/O module is not functional.
- The adapter firmware has failed.
- The adapter is not functional
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the POST results for the server. In Cisco FPR Manager GUI, you can access the POST results from the General tab for the server. In Cisco FPR Manager CLI, you can access the POST results through the show post command under the scope for the server.
Step 2 In Cisco FPR Manager, check the power state of the server.
Step 3 Verify that the physical server has the same power state.
Step 4 If the server is off, turn the server on.
Step 5 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: connectivity-problem
mibFaultName: fltAdaptorUnitAdaptorReachability
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]
fltAdaptorHostIfLink-down
Fault Code: F0207
Message
Adapter [transport] host interface [id]/[id]/[id] link state: [linkState], Associated external interface link state: [vcAdminState]Adapter [transport] host interface [chassisId]/[slotId]/[id]/[id] link state: [linkState], Associated external interface link state: [vcAdminState]
Explanation
This fault typically occurs as a result of one of the following issues:
- The fabric interconnect is in End-Host mode, and all uplink ports failed.
- The server port to which the adapter is pinned failed.
- A transient error caused the link to fail.
Recommended Action
If you see this fault, take the following actions:
Step 1 If an associated port is disabled, enable the port.
Step 2 Check the associated port to ensure it is in up state.
Step 3 Reacknowledge the server with the adapter that has the failed link.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Step 5 vnic link state will be down, when its associated external interface is down.The fault should not be displayed regardless if it is administratively disabled or if it is operationally not up(i.e. physical link is detected as down).
Fault Details
mibFaultName: fltAdaptorHostIfLinkDown
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]
fltAdaptorExtIfLink-down
Fault Code: F0209
Message
Adapter uplink interface [chassisId]/[slotId]/[id]/[id] on security module [slotId] link state: [linkState]. Please check switch blade-facing port status. Resetting security module might be required.
Explanation
The link for a network facing adapter interface is down. Cisco FPR Manager raises this fault when any of the following scenarios occur:
- Cisco FPR Manager cannot establish and/or validate the adapter’s connectivity to any of the fabric interconnects.
- The endpoint reports a link down or vNIC down event on the adapter link.
- The endpoint reports an errored link state or errored vNIC state event on the adapter link.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the adapter is connected, configured properly, and is running the recommended firmware version.
Step 2 If the server is stuck at discovery, decommission the server and reacknowledge the server slot.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltAdaptorExtIfLinkDown
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]
fltPortPIoLink-down
Fault Code: F0276
Message
[transport] port [portId] on chassis [id] oper state: [operState], reason: [stateQual][transport] port [slotId]/[aggrPortId]/[portId] on fabric interconnect [id] oper state: [operState], reason: [stateQual][transport] port [slotId]/[portId] on fabric interconnect [id] oper state: [operState], reason: [stateQual]
Explanation
This fault occurs when a fabric interconnect port is in link-down state. This state impacts the traffic destined for the port.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the physical link is properly connected between the fabric interconnect and the peer component.
Step 2 Verify that the configuration on the peer entity is properly configured and matches the fabric interconnect port configuration.
Step 3 Unconfigure and re-configure the port.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltPortPIoLinkDown
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]
fltPortPIoFailed
Fault Code: F0277
Message
[transport] port [portId] on chassis [id] oper state: [operState], reason: [stateQual][transport] port [slotId]/[aggrPortId]/[portId] on fabric interconnect [id] oper state: [operState], reason: [stateQual][transport] port [slotId]/[portId] on fabric interconnect [id] oper state: [operState], reason: [stateQual]
Explanation
This fault is raised on fabric interconnect ports and on server-facing ports on an IOM or a FEX module when FPRM detects that the port is not up and in failed state while it is expected to be up since it has been enabled by user and there is no known hardware failure or missing SFP issue and port license is valid. Additional reason is displayed by the fault description string.
Recommended Action
If you see this fault, Corrective action maybe taken based on reason information in the fault description whenever such a reason is displayed. If the fault description displays reason as "ENM source pinning failed" then it means that the fabric interconnect is operating in End-host Node Mode and the uplink port that this server facing port is pinned to is down or does not have appropriate VLAN configured. In case of such an error for an appliance port check the VLAN configuration on uplink port. A VLAN with same id as the one on the appliance port will also need to be configured on the uplink port. After setting the configuration right if you still see the fault then create a show tech-support file for Cisco FPR Manager and the chassis or FEX module, and then contact Cisco TAC.
Fault Details
mibFaultName: fltPortPIoFailed
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]
fltPortPIoHardware-failure
Fault Code: F0278
Message
[transport] port [portId] on chassis [id] oper state: [operState], reason: hardware-failure[transport] port [slotId]/[aggrPortId]/[portId] on fabric interconnect [id] oper state: [operState], reason: hardware-failure[transport] port [slotId]/[portId] on fabric interconnect [id] oper state: [operState], reason: hardware-failure
Explanation
This fault is raised on fabric interconnect ports and server-facing ports on an IOM or a FEX module when the system detects a hardware failure.
Recommended Action
If you see this fault, create a show tech-support file for Cisco FPR Manager and the chassis or FEX module, and then contact Cisco TAC.
Fault Details
mibFaultName: fltPortPIoHardwareFailure
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]
fltPortPIoSfp-not-present
Fault Code: F0279
Message
[transport] port [portId] on chassis [id] oper state: [operState][transport] port [slotId]/[aggrPortId]/[portId] on fabric interconnect [id] oper state: [operState][transport] port [slotId]/[portId] on fabric interconnect [id] oper state: [operState]
Explanation
When a fabric interconnect port is not in an unconfigured state, an SFP is required for its operation. This fault is raised to indicate that the SFP is missing from a configured port.
Recommended Action
If you see this fault, insert a supported SFP into the port on the fabric interconnect. A list of supported SFPs can be found on www.Cisco.com.
Fault Details
mibFaultName: fltPortPIoSfpNotPresent
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]
fltFabricExternalPcDown
Fault Code: F0282
Message
[type] port-channel [portId] on fabric interconnect [switchId] oper state: [operState], reason: [stateQual][type] port-channel [portId] on fabric interconnect [switchId] oper state: [operState], reason: [stateQual]
Explanation
This fault typically occurs when a fabric interconnect reports that a fabric port channel is operationally down.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the member ports in the fabric port channel are administratively up and operational. Check the link connectivity for each port.
Step 2 If connectivity seems correct, check the operational states on the peer switch ports of the port channel members.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: operational-state-down
mibFaultName: fltFabricExternalPcDown
moClass: fabric:ExternalPc
Affected MO: fabric/eth-estc/[id]/net-[name]/pc-switch-[switchId]-pc-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]
Affected MO: fabric/eth-estc/net-[name]/pc-switch-[switchId]-pc-[portId]
Affected MO: fabric/lan/[id]/net-[name]/pc-switch-[switchId]-pc-[portId]
Affected MO: fabric/lan/[id]/net-group-[name]/pc-switch-[switchId]-pc-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]
Affected MO: fabric/lan/net-[name]/pc-switch-[switchId]-pc-[portId]
Affected MO: fabric/lan/net-group-[name]/pc-switch-[switchId]-pc-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]
Affected MO: fabric/san/[id]/net-[name]/fcoepc-switch-[switchId]-fcoepc-[portId]
Affected MO: fabric/san/[id]/net-[name]/pc-switch-[switchId]-pc-[portId]
Affected MO: fabric/san/[id]/pc-[portId]
Affected MO: fabric/san/net-[name]/fcoepc-switch-[switchId]-fcoepc-[portId]
Affected MO: fabric/san/net-[name]/pc-switch-[switchId]-pc-[portId]
fltDcxVcDown
Fault Code: F0283
Message
[transport] VIF [id] on server [chassisId] / [slotId] of switch [switchId] down, reason: [stateQual][transport] VIF [id] on server [id] of switch [switchId] down, reason: [stateQual]
Explanation
This fault typically occurs when a fabric interconnect reports one of the following connectivity states for a virtual interface:
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the uplink physical interface is up.
Step 2 Check the associated port to ensure it is in up state.
Step 3 If the vNIC/vHBA is configured for a pin group, verify that the pin group targets are configured correctly.
Step 4 In the Network Control Policy for the vNIC, verify that the ’Action on Uplink Fail’ field is set to ’warning’.
Step 5 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltDcxVcDown
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/fex-[id]/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/fex-[id]/fabric-[switchId]/vc-[id]
Affected MO: sys/fex-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/fex-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/vc-[id]
Affected MO: sys/switch-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/switch-[id]/mgmt/fabric-[switchId]/vc-[id]
fltNetworkElementInoperable
Fault Code: F0291
Message
Fabric Interconnect [id] operability: [operability]
Explanation
This fault typically occurs when the fabric interconnect cluster controller reports that the membership state of the fabric interconnect is down, indicating that the fabric interconnect is inoperable.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that both fabric interconnects in the cluster are running the same Kernel and System software versions.
Step 2 Verify that the fabric interconnects software version and the Cisco FPR Manager software versions are the same.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inoperable
mibFaultName: fltNetworkElementInoperable
Affected MO: sys/switch-[id]
fltMgmtEntityDegraded
Fault Code: F0293
Message
Fabric Interconnect [id], HA Cluster interconnect link failure
Explanation
This fault occurs when one of the cluster links (either L1 or L2) of a fabric interconnect is not operationally up. This issue impacts the full HA functionality of the fabric interconnect cluster.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that both L1 and L2 links are properly connected between the fabric interconnects.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltMgmtEntityDegraded
Affected MO: sys/mgmt-entity-[id]
fltMgmtEntityDown
Fault Code: F0294
Message
Fabric Interconnect [id], HA Cluster interconnect total link failure
Explanation
This fault occurs when both cluster links (L1 and L2) of the fabric interconnects are in a link-down state. This issue impacts the full HA functionality of the fabric interconnect cluster.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that both L1 and L2 links are properly connected between the fabric interconnects.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltMgmtEntityDown
Affected MO: sys/mgmt-entity-[id]
fltDcxNsFailed
Fault Code: F0304
Message
Server [chassisId]/[slotId] (service profile: [assignedToDn]) virtual network interface allocation failed.Server [id] (service profile: [assignedToDn]) virtual network interface allocation failed.
Explanation
The adapter’s vif-namespace activation failed due to insufficient resources. Cisco FPR Manager raises this fault when the number of deployed VIF resources exceeds the maximum VIF resources available on the adapter connected to the fabric interconnect.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the NS "size" and "used" resources to determine by how many vNICs the adapter exceeded the maximum.
Step 2 Unconfigure or delete all vNICs on the adapter above the maximum number.
Step 3 Add additional fabric uplinks from the IOM to the corresponding fabric interconnect and reacknowledge the chassis. This increases the "NS size" on the adapter.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: insufficient-resources
mibFaultName: fltDcxNsFailed
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/dcxns-[switchId]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/dcxns-[switchId]
fltComputePhysicalInsufficientlyEquipped
Fault Code: F0305
Message
Server [id] (service profile: [assignedToDn]) has insufficient number of DIMMs, CPUs and/or adaptersServer [chassisId]/[slotId] (service profile: [assignedToDn]) has insufficient number of DIMMs, CPUs and/or adapters
Explanation
This fault typically occurs because Cisco FPR Manager has detected that the server has an insufficient number of DIMMs, CPUs, and/or adapters.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the DIMMs are installed in a supported configuration.
Step 2 Verify that an adapter and CPU are installed.
Step 3 Reacknowledge the server.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: insufficiently-equipped
mibFaultName: fltComputePhysicalInsufficientlyEquipped
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalIdentityUnestablishable
Fault Code: F0306
Message
Server [id] (service profile: [assignedToDn]) has an invalid FRUServer [chassisId]/[slotId] (service profile: [assignedToDn]) has an invalid FRU
Explanation
This fault typically occurs because Cisco FPR Manager has detected an unsupported server or CPU.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that a supported server and/or CPU is installed.
Step 2 Verify that the Cisco FPR Manager capability catalog is up to date.
Step 3 Reacknowledge the server.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: identity-unestablishable
mibFaultName: fltComputePhysicalIdentityUnestablishable
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/rack-unit-[id]
fltComputeBoardPowerError
Fault Code: F0310
Message
Motherboard of server [chassisId]/[slotId] (service profile: [assignedToDn]) power: [operPower]Motherboard of server [id] (service profile: [assignedToDn]) power: [operPower]
Explanation
This fault typically occurs when the server power sensors have detected a problem.
Recommended Action
If you see this fault, take the following actions:
Step 1 Make sure that the server is correctly installed in the chassis and that all cables are secure.
Step 2 If you reinstalled the server, reacknowledge it.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltComputeBoardPowerError
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/rack-unit-[id]/board
fltComputePhysicalPowerProblem
Fault Code: F0311
Message
Server [id] (service profile: [assignedToDn]) oper state: [operState]Server [chassisId]/[slotId] (service profile: [assignedToDn]) oper state: [operState]
Explanation
This fault typically occurs when the server power sensors have detected a problem.
Recommended Action
If you see this fault, take the following actions:
Step 1 Make sure that the server is correctly installed in the chassis and that all cables are secure.
Step 2 If you reinstalled the server, reacknowledge it.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltComputePhysicalPowerProblem
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalThermalProblem
Fault Code: F0312
Message
Server [id] (service profile: [assignedToDn]) oper state: [operState]Server [chassisId]/[slotId] (service profile: [assignedToDn]) oper state: [operState]
Explanation
This fault typically occurs when the server thermal sensors have detected a problem.
Recommended Action
If you see this fault, take the following actions:
Step 1 Make sure that the server fans are working properly.
Step 2 Wait for 24 hours to see if the problem resolves itself.
Step 3 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltComputePhysicalThermalProblem
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalBiosPostTimeout
Fault Code: F0313
Message
Server [id] (service profile: [assignedToDn]) BIOS failed power-on self testBlade [chassisId]/[slotId] (service profile: [assignedToDn]) BIOS failed power-on self test
Explanation
This fault typically occurs when the server has encountered a diagnostic failure.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the POST results for the server. In Cisco FPR Manager GUI, you can access the POST results from the General tab for the server. In Cisco FPR Manager CLI, you can access the POST results through the show post command under the scope for the server.
Step 2 Reacknowledge the server.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inoperable
mibFaultName: fltComputePhysicalBiosPostTimeout
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalDiscoveryFailed
Fault Code: F0314
Message
Server [id] (service profile: [assignedToDn]) discovery: [discovery]Server [chassisId]/[slotId] (service profile: [assignedToDn]) discovery: [discovery]
Explanation
This fault typically occurs for one of the following reasons:
- The shallow discovery that occurs when the server associated with service profile failed.
- The server is down.
- The data path is not working.
- Cisco FPR Manager cannot communicate with the CIMC on the server.
- The server cannot communicate with the fabric interconnect.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the FSM tab and the current state of the server and any FSM operations.
Step 2 Check the error descriptions and see if any server components indicate a failure.
Step 3 If the server or a server component has failed, do the following:
a. Check the operational state of the server.
b. If the server is not operable, re-acknowledge the server.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltComputePhysicalDiscoveryFailed
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalAssociationFailed
Fault Code: F0315
Message
Service profile [assignedToDn] failed to associate with server [id]Service profile [assignedToDn] failed to associate with server [chassisId]/[slotId]
Explanation
This fault typically occurs for one of the following reasons:
- The service profile could not be associated with the server.
- The server is down.
- The data path is not working.
- Cisco FPR Manager cannot communicate with one or more of the fabric interconnect, the server, or a component on the server.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the FSM tab and the current state of the server and any FSM operations.
Step 2 If the server is stuck in an inappropriate state, such as booting, power cycle the server.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: association-failed
mibFaultName: fltComputePhysicalAssociationFailed
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalInoperable
Fault Code: F0317
Message
Server [id] (service profile: [assignedToDn]) health: [operability]Server [chassisId]/[slotId] (service profile: [assignedToDn]) health: [operability]
Explanation
This fault typically occurs when the server has encountered a diagnostic failure.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the POST results for the server.In Cisco FPR Manager GUI, you can access the POST results from the General tab for the server. In Cisco FPR Manager CLI, you can access the POST results through the show post command under the scope for the server.
Step 2 Reacknowledge the server.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inoperable
mibFaultName: fltComputePhysicalInoperable
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalUnassignedMissing
Fault Code: F0318
Message
Server [id] (no profile) missingServer [chassisId]/[slotId] (no profile) missing
Explanation
This fault typically occurs when the server, which is not associated with a service profile, was previously physically inserted in the slot, but cannot be detected by Cisco FPR Manager.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the server is physically present in the slot, remove and then reinsert it.
Step 2 If the server is not physically present in the slot, insert it.
Step 3 Reacknowledge the server.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltComputePhysicalUnassignedMissing
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalAssignedMissing
Fault Code: F0319
Message
Server [id] (service profile: [assignedToDn]) missingServer [chassisId]/[slotId] (service profile: [assignedToDn]) missing
Explanation
This fault typically occurs when the server, which is associated with a service profile, was previously physically inserted in the slot, but cannot be detected by Cisco FPR Manager.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the server is physically present in the slot, remove and then reinsert it.
Step 2 If the server is not physically present in the slot, reinsert it.
Step 3 Reacknowledge the server.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltComputePhysicalAssignedMissing
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalUnidentified
Fault Code: F0320
Message
Server [id] (service profile: [assignedToDn]) has an invalid FRU: [presence]Server [chassisId]/[slotId] (service profile: [assignedToDn]) has an invalid FRU: [presence]
Explanation
This fault typically occurs because Cisco FPR Manager has detected an unsupported server or CPU.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that a supported server and/or CPU is installed.
Step 2 Verify that the Cisco FPR Manager capability catalog is up to date.
Step 3 Reacknowledge the server.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: identity-unestablishable
mibFaultName: fltComputePhysicalUnidentified
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalUnassignedInaccessible
Fault Code: F0321
Message
Server [id] (no profile) inaccessibleServer [chassisId]/[slotId] (no profile) inaccessible
Explanation
This fault typically occurs when the server, which is not associated with a service profile, has lost connection to the fabric interconnects. This fault occurs if there are communication issues between the server CIMC and the fabric interconnects.
Recommended Action
If you see this fault, take the following actions:
Step 1 Wait a few minutes to see if the fault clears. This is typically a temporary issue, and can occur after a firmware upgrade.
Step 2 If the fault does not clear after a brief time, remove the server and then reinsert it.
Step 3 Reacknowledge the server.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inaccessible
mibFaultName: fltComputePhysicalUnassignedInaccessible
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalAssignedInaccessible
Fault Code: F0322
Message
Server [id] (service profile: [assignedToDn]) inaccessibleServer [chassisId]/[slotId] (service profile: [assignedToDn]) inaccessible
Explanation
This fault typically occurs when the server, which is associated with a service profile, has lost connection to the fabric interconnects. This fault occurs if there are communication issues between the server CIMC and the fabric interconnects.
Recommended Action
If you see this fault, take the following actions:
Step 1 Wait a few minutes to see if the fault clears. This is typically a temporary issue, and can occur after a firmware upgrade.
Step 2 If the fault does not clear after a brief time, remove the server and then reinsert it.
Step 3 Reacknowledge the server.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inaccessible
mibFaultName: fltComputePhysicalAssignedInaccessible
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/rack-unit-[id]
fltLsServerFailed
Fault Code: F0324
Message
Service profile [name] failed
Explanation
Server has failed. This fault typically occurs if the adapter power on self-test results in major and critical errors.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the POST results for the server. In Cisco FPR Manager GUI, you can access the POST results from the General tab for the server. In Cisco FPR Manager CLI, you can access the POST results through the show post command under the scope for the server.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltLsServerFailed
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]
fltLsServerDiscoveryFailed
Fault Code: F0326
Message
Service profile [name] discovery failed
Explanation
The shallow discovery that occurs when the server associated with service profile fails. If the server is up and the data path is working, this fault typically occurs as a result of one of the following issues:
- Cisco FPR Manager cannot communicate with the CIMC on the server.
- The server cannot communicate with the fabric interconnect.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the FSM tab and view the current state of the server and any FSM operations.
Step 2 Check the error descriptions and see if any server components indicate a failure.
Step 3 If the server or a server component has failed, do the following:
a. Check the operational state of the server.
b. If the server is not operable, reacknowledge the server.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltLsServerDiscoveryFailed
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]
fltLsServerConfigFailure
Fault Code: F0327
Message
Service profile [name] configuration failed due to [configQualifier]
Explanation
The named configuration qualifier is not available. This fault typically occurs because Cisco FPR Manager cannot successfully deploy the service profile due to a lack of resources that meet the named qualifier. For example, this fault can occur if the following occurs:
- The service profile is configured for a server adapter with vHBAs, and the adapter on the server does not support vHBAs.
- The service profile is created from a template which includes a server pool, and the server pool is empty.
- The local disk configuration policy in the service profile specifies the No Local Storage mode, but the server contains local disks.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the status of the server pool associated with the service profile. If the pool is empty, add more blade servers to it.
Step 2 Check the state of the server and ensure that it is in either the discovered or unassociated state.
Step 3 If the server is associated or undiscovered, do one of the following:
– Discover the server.
– Disassociate the server from the current service profile.
– Select another server to associate with the service profile.
Step 4 Review each policy in the service profile and verify that the selected server meets the requirements in the policy.
Step 5 If the server does not meet the requirements of the service profile, do one of the following:
– Modify the service profile to match the server.
– Select another server that does meet the requirements to associate with the service profile.
Step 6 If you can verify that the server meets the requirements of the service profile, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: configuration-failure
mibFaultName: fltLsServerConfigFailure
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]
fltLsServerMaintenanceFailed
Fault Code: F0329
Message
Service profile [name] maintenance failed
Explanation
Cisco FPR Manager currently does not use this fault.
Recommended Action
If you see this fault, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: maintenance-failed
mibFaultName: fltLsServerMaintenanceFailed
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]
fltLsServerRemoved
Fault Code: F0330
Message
Service profile [name] underlying resource removed
Explanation
Cisco FPR Manager cannot access the server associated with the service profile. This fault typically occurs as a result of one of the following issues:
- The server has been physically removed from the slot.
- The server is not available.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the server was removed from the slot, reinsert the server in the slot.
Step 2 If the server was not removed, remove and reinsert the server.NOTE: If the server is operable, this action can be disruptive to current operations.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltLsServerRemoved
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]
fltLsServerInaccessible
Fault Code: F0331
Message
Service profile [name] cannot be accessed
Explanation
Cisco FPR Manager cannot communicate with the CIMC on the server. This fault typically occurs as a result of one of the following issues:
- The server port or ports have failed.
- The I/O module is offline.
- The BMC has failed.
Recommended Action
If you see this fault, take the following actions:
Step 1 If Cisco FPR Manager shows that the CIMC is down, physically reseat the server.
Step 2 If Cisco FPR Manager shows that the server ports have failed, attempt to enable them.
Step 3 If the I/O module is offline, check for faults on that component.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: server-inaccessible
mibFaultName: fltLsServerInaccessible
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]
fltLsServerAssociationFailed
Fault Code: F0332
Message
Service profile [name] association failed for [pnDn]
Explanation
The service profile could not be associated with the server. This fault typically occurs because Cisco FPR Manager cannot communicate with one or more of the following:
- Fabric interconnect
- CIMC on the server
- SAS controller driver
- Server
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the FSM tab for the server and service profile to determine why the association failed.
Step 2 If the server is stuck in an inappropriate state, such as booting, power cycle the server.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: association-failed
mibFaultName: fltLsServerAssociationFailed
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]
fltLsServerUnassociated
Fault Code: F0334
Message
Service profile [name] is not associated
Explanation
The service profile has not yet been associated with a server or a server pool. This fault typically occurs as a result of one of the following issues:
- There is no acceptable server in the server pool.
- The association failed.
Recommended Action
If you see this fault, take the following actions:
Step 1 If you did not intend to associate the service profile, ignore the fault.
Step 2 If you did intend to associate the service profile, check the association failure fault.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltLsServerUnassociated
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]
fltLsServerServer-unfulfilled
Fault Code: F0337
Message
Server [pnDn] does not fulfill Service profile [name] due to [configQualifier]
Explanation
The server no longer meets the qualification requirements of the service profile. This fault typically occurs as a result of one of the following issues:
- The server has been physically changed.
- A required component of the server has failed.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the server inventory compare to the service profile qualifications.
Step 2 If the server inventory does not match the service profile qualifications, do one of the following:
– Associate the server with a different service profile.
– Ensure the server has sufficient resources to qualify for the current service profile.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltLsServerServerUnfulfilled
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]
fltEtherSwitchIntFIoSatellite-connection-absent
Fault Code: F0367
Message
No link between IOM port [chassisId]/[slotId]/[portId] and fabric interconnect [switchId]:[peerSlotId]/[peerPortId]
Explanation
This fault is raised when an I/O module fabric port, which links the I/O module port and the fabric interconnect, is not functional
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify the fabric interconnect-chassis topology. Make sure each I/O module is connected to only one fabric interconnect.
Step 2 Ensure that the fabric interconnect server port is configured and enabled.
Step 3 Ensure that the links are plugged in properly and reacknowledge the chassis.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: satellite-connection-absent
mibFaultName: fltEtherSwitchIntFIoSatelliteConnectionAbsent
moClass: ether:SwitchIntFIo
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]
fltEtherSwitchIntFIoSatellite-wiring-problem
Fault Code: F0368
Message
Invalid connection between IOM port [chassisId]/[slotId]/[portId] and fabric interconnect [switchId]:[peerSlotId]/[peerPortId]
Explanation
This fault typically occurs as a result of a satellite wiring problem on the network-facing interface of an I/O module and Cisco FPR Manager detects that at least one IOM uplink is misconnected to one of the fabric interconnect ports.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify the fabric interconnect-chassis topology. Make sure each I/O module is connected to only one fabric interconnect.
Step 2 Ensure that the links are plugged in properly and re-acknowledge the chassis.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: satellite-mis-connected
mibFaultName: fltEtherSwitchIntFIoSatelliteWiringProblem
moClass: ether:SwitchIntFIo
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]
fltEquipmentPsuPowerSupplyProblem
Fault Code: F0369
Message
Power supply [id] in chassis [id] power: [power]Power supply [id] in fabric interconnect [id] power: [power]Power supply [id] in fex [id] power: [power]Power supply [id] in server [id] power: [power]
Explanation
This fault typically occurs when Cisco FPR Manager detects a problem with a power supply unit in a chassis, fabric interconnect or a FEX. For example, the PSU is not functional.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the power cord is properly connected to the PSU and the power source.
Step 2 Verify that the power source is 220 volts.
Step 3 Verify that the PSU is properly installed in the chassis or fabric interconnect.
Step 4 Remove the PSU and reinstall it.
Step 5 Replace the PSU.
Step 6 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentPsuPowerSupplyProblem
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentFanDegraded
Fault Code: F0371
Message
Fan [id] in Fan Module [tray]-[id] under chassis [id] operability: [operability]Fan [id] in fabric interconnect [id] operability: [operability]Fan [id] in fex [id] operability: [operability]Fan [id] in Fan Module [tray]-[id] under server [id] operability: [operability]
Explanation
This fault occurs when one or more fans in a fan module are not operational, but at least one fan is operational.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the fan module.
Step 2 Review the Cisco FPR Site Preparation Guide and ensure the fan module has adequate airflow, including front and back clearance.
Step 3 Verify that the air flows are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Replace the faulty fan modules.
Step 8 Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 9 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-degraded
mibFaultName: fltEquipmentFanDegraded
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/fex-[id]/fan-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]
fltEquipmentFanInoperable
Fault Code: F0373
Message
Fan [id] in Fan Module [tray]-[id] under chassis [id] operability: [operability]Fan [id] in fabric interconnect [id] operability: [operability]Fan [id] in fex [id] operability: [operability]Fan [id] in Fan Module [tray]-[id] under server [id] operability: [operability]
Explanation
This fault occurs if a fan is not operational.
Recommended Action
If you see this fault, take the following actions:
Step 1 Remove fan module and re-install the fan module again. Remove only one fan module at a time.
Step 2 Replace fan module with a different fan module
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inoperable
mibFaultName: fltEquipmentFanInoperable
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/fex-[id]/fan-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]
fltEquipmentPsuInoperable
Fault Code: F0374
Message
Power supply [id] in chassis [id] operability: [operability]Power supply [id] in fabric interconnect [id] operability: [operability]Power supply [id] in fex [id] operability: [operability]Power supply [id] in server [id] operability: [operability]
Explanation
This fault typically occurs when Cisco FPR Manager detects a problem with a power supply unit in a chassis, fabric interconnect or a FEX. For example, the PSU is not functional.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the power cord is properly connected to the PSU and the power source.
Step 2 Verify that the power source is 220 volts.
Step 3 Verify that the PSU is properly installed in the chassis or fabric interconnect.
Step 4 Remove the PSU and reinstall it.
Step 5 Replace the PSU.
Step 6 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inoperable
mibFaultName: fltEquipmentPsuInoperable
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentIOCardRemoved
Fault Code: F0376
Message
[side] IOM [chassisId]/[id] ([switchId]) is removed
Explanation
This fault typically occurs because an I/O module is removed from the chassis. In a cluster configuration, the chassis fails over to the other I/O module. For a standalone configuration, the chassis associated with the I/O module loses network connectivity. This is a critical fault because it can result in the loss of network connectivity and disrupt data traffic through the I/O module.
Recommended Action
If you see this fault, take the following actions:
Step 1 Reinsert the I/O module and configure the fabric-interconnect ports connected to it as server ports and wait a few minutes to see if the fault clears.
Step 2 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentIOCardRemoved
moClass: equipment:IOCard
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltEquipmentFanModuleMissing
Fault Code: F0377
Message
Fan module [tray]-[id] in chassis [id] presence: [presence]Fan module [tray]-[id] in server [id] presence: [presence]Fan module [tray]-[id] in fabric interconnect [id] presence: [presence]
Explanation
This fault occurs if a fan Module slot is not equipped or removed from its slot
Recommended Action
If you see this fault, take the following actions:
Step 1 If the reported slot is empty, insert a fan module into the slot.
Step 2 If the reported slot contains a fan module, remove and reinsert the fan module.
Step 3 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentFanModuleMissing
moClass: equipment:FanModule
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]
fltEquipmentPsuMissing
Fault Code: F0378
Message
Power supply [id] in chassis [id] presence: [presence]Power supply [id] in fabric interconnect [id] presence: [presence]Power supply [id] in fex [id] presence: [presence]Power supply [id] in server [id] presence: [presence]
Explanation
This fault typically occurs when Cisco FPR Manager detects a problem with a power supply unit in a chassis, fabric interconnect, or a FEX. For example, the PSU is missing.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the PSU is physically present in the slot, remove and then reinsert it.
Step 2 If the PSU is not physically present in the slot, insert a new PSU.
Step 3 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentPsuMissing
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentIOCardThermalProblem
Fault Code: F0379
Message
[side] IOM [chassisId]/[id] ([switchId]) operState: [operState]
Explanation
This fault occurs when there is a thermal problem on an I/O module. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the I/O module.
Step 2 Review the Cisco FPR Site Preparation Guide to ensure the I/O modules have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco FPR chassis are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Replace faulty I/O modules.
Step 8 Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 9 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentIOCardThermalProblem
moClass: equipment:IOCard
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltEquipmentFanModuleThermalThresholdNonCritical
Fault Code: F0380
Message
Fan module [tray]-[id] in chassis [id] temperature: [thermal]Fan module [tray]-[id] in server [id] temperature: [thermal]Fan module [tray]-[id] in fabric interconnect [id] temperature: [thermal]
Explanation
This fault occurs when the temperature of a fan module has exceeded a non-critical threshold value, but is still below the critical threshold. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the fan module.
Step 2 Review the Cisco FPR Site Preparation Guide to ensure the fan modules have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Replace faulty fan modules.
Step 8 Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 9 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentFanModuleThermalThresholdNonCritical
moClass: equipment:FanModule
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]
fltEquipmentPsuThermalThresholdNonCritical
Fault Code: F0381
Message
Power supply [id] in chassis [id] temperature: [thermal]Power supply [id] in fabric interconnect [id] temperature: [thermal]Power supply [id] in server [id] temperature: [thermal]
Explanation
This fault occurs when the temperature of a PSU module has exceeded a non-critical threshold value, but is still below the critical threshold. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the PSU module.
Step 2 Review the Cisco FPR Site Preparation Guide to ensure the PSU modules have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Replace faulty PSU modules.
Step 8 Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 9 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentPsuThermalThresholdNonCritical
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentFanModuleThermalThresholdCritical
Fault Code: F0382
Message
Fan module [tray]-[id] in chassis [id] temperature: [thermal]Fan module [tray]-[id] in server [id] temperature: [thermal]Fan module [tray]-[id] in fabric interconnect [id] temperature: [thermal]
Explanation
This fault occurs when the temperature of a fan module has exceeded a critical threshold value. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the fan module.
Step 2 Review the Cisco FPR Site Preparation Guide to ensure the fan modules have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Replace faulty fan modules.
Step 8 Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 9 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentFanModuleThermalThresholdCritical
moClass: equipment:FanModule
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]
fltEquipmentPsuThermalThresholdCritical
Fault Code: F0383
Message
Power supply [id] in chassis [id] temperature: [thermal]Power supply [id] in fabric interconnect [id] temperature: [thermal]Power supply [id] in server [id] temperature: [thermal]
Explanation
This fault occurs when the temperature of a PSU module has exceeded a critical threshold value. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the PSU module.
Step 2 Review the Cisco FPR Site Preparation Guide to ensure the PSU modules have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Replace faulty PSU modules.
Step 8 Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 9 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentPsuThermalThresholdCritical
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentFanModuleThermalThresholdNonRecoverable
Fault Code: F0384
Message
Fan module [tray]-[id] in chassis [id] temperature: [thermal]Fan module [tray]-[id] in server [id] temperature: [thermal]Fan module [tray]-[id] in fabric interconnect [id] temperature: [thermal]
Explanation
This fault occurs when the temperature of a fan module has been out of operating range, and the issue is not recoverable. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the fan module.
Step 2 Review the Cisco FPR Site Preparation Guide to ensure the fan modules have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Replace faulty fan modules.
Step 8 Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 9 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentFanModuleThermalThresholdNonRecoverable
moClass: equipment:FanModule
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]
fltEquipmentPsuThermalThresholdNonRecoverable
Fault Code: F0385
Message
Power supply [id] in chassis [id] temperature: [thermal]Power supply [id] in fabric interconnect [id] temperature: [thermal]Power supply [id] in server [id] temperature: [thermal]
Explanation
This fault occurs when the temperature of a PSU module has been out of operating range, and the issue is not recoverable. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the PSU module.
Step 2 Review the Cisco FPR Site Preparation Guide to ensure the PSU modules have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Replace faulty PSU modules.
Step 8 Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 9 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentPsuThermalThresholdNonRecoverable
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentPsuVoltageThresholdNonCritical
Fault Code: F0387
Message
Power supply [id] in chassis [id] voltage: [voltage]Power supply [id] in fabric interconnect [id] voltage: [voltage]Power supply [id] in fex [id] voltage: [voltage]Power supply [id] in server [id] voltage: [voltage]
Explanation
This fault occurs when the PSU voltage is out of normal operating range, but hasn’t reached to a critical stage yet. Normally the PSU will recover itself from this situation.
Recommended Action
If you see this fault, take the following actions:
Step 1 Monitor the PSU for further degradation.
Step 2 Remove and reseat the PSU.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentPsuVoltageThresholdNonCritical
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentPsuVoltageThresholdCritical
Fault Code: F0389
Message
Power supply [id] in chassis [id] voltage: [voltage]Power supply [id] in fabric interconnect [id] voltage: [voltage]Power supply [id] in fex [id] voltage: [voltage]Power supply [id] in server [id] voltage: [voltage]
Explanation
This fault occurs when the PSU voltage has exceeded the specified hardware voltage rating.
Recommended Action
If you see this fault, take the following actions:
Step 1 Remove and reseat the PSU.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentPsuVoltageThresholdCritical
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentPsuVoltageThresholdNonRecoverable
Fault Code: F0391
Message
Power supply [id] in chassis [id] voltage: [voltage]Power supply [id] in fabric interconnect [id] voltage: [voltage]Power supply [id] in fex [id] voltage: [voltage]Power supply [id] in server [id] voltage: [voltage]
Explanation
This fault occurs when the PSU voltage has exceeded the specified hardware voltage rating and PSU hardware may have been damaged as a result or may be at risk of being damaged.
Recommended Action
If you see this fault, take the following actions:
Step 1 Remove and reseat the PSU.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentPsuVoltageThresholdNonRecoverable
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentPsuPerfThresholdNonCritical
Fault Code: F0392
Message
Power supply [id] in chassis [id] output power: [perf]Power supply [id] in fabric interconnect [id] output power: [perf]Power supply [id] in server [id] output power: [perf]
Explanation
This fault is raised as a warning if the current output of the PSU in a chassis, fabric interconnect, or rack server does not match the desired output value.
Recommended Action
If you see this fault, take the following actions:
Step 1 Monitor the PSU status.
Step 2 If possible, remove and reseat the PSU.
Step 3 If the above action did not resolve the issue, create a show tech-support file for the chassis and Cisco FPR Manager, and contact Cisco TAC.
Fault Details
Cause: performance-problem
mibFaultName: fltEquipmentPsuPerfThresholdNonCritical
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentPsuPerfThresholdCritical
Fault Code: F0393
Message
Power supply [id] in chassis [id] output power: [perf]Power supply [id] in fabric interconnect [id] output power: [perf]Power supply [id] in server [id] output power: [perf]
Explanation
This fault occurs if the current output of the PSU in a chassis, fabric interconnect, or rack server is far below or above the desired output value.
Recommended Action
If you see this fault, take the following actions:
Step 1 Monitor the PSU status.
Step 2 Plan to replace the PSU as soon as possible.
Step 3 If the above actions did not resolve the issue, create a show tech-support file for the chassis and Cisco FPR Manager, and contact Cisco TAC.
Fault Details
Cause: performance-problem
mibFaultName: fltEquipmentPsuPerfThresholdCritical
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentPsuPerfThresholdNonRecoverable
Fault Code: F0394
Message
Power supply [id] in chassis [id] output power: [perf]Power supply [id] in fabric interconnect [id] output power: [perf]Power supply [id] in server [id] output power: [perf]
Explanation
This fault occurs if the current output of the PSU in a chassis, fabric interconnect, or rack server is far above or below the non-recoverable threshold value.
Recommended Action
If you see this fault, plan to replace the PSU as soon as possible.
Fault Details
Cause: performance-problem
mibFaultName: fltEquipmentPsuPerfThresholdNonRecoverable
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentFanPerfThresholdNonCritical
Fault Code: F0395
Message
Fan [id] in Fan Module [tray]-[id] under chassis [id] speed: [perf]Fan [id] in fabric interconnect [id] speed: [perf]Fan [id] in Fan Module [tray]-[id] under server [id] speed: [perf]
Explanation
This fault occurs when the fan speed reading from the fan controller does not match the desired fan speed and is outside of the normal operating range. This can indicate a problem with a fan or with the reading from the fan controller.
Recommended Action
If you see this fault, take the following actions:
Step 1 Monitor the fan status.
Step 2 If the problem persists for a long period of time or if other fans do not show the same problem, reseat the fan.
Step 3 Replace the fan module.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: performance-problem
mibFaultName: fltEquipmentFanPerfThresholdNonCritical
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/fex-[id]/fan-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]
fltEquipmentFanPerfThresholdCritical
Fault Code: F0396
Message
Fan [id] in Fan Module [tray]-[id] under chassis [id] speed: [perf]Fan [id] in fabric interconnect [id] speed: [perf]Fan [id] in Fan Module [tray]-[id] under server [id] speed: [perf]
Explanation
This fault occurs when the fan speed read from the fan controller does not match the desired fan speed and has exceeded the critical threshold and is in risk of failure. This can indicate a problem with a fan or with the reading from the fan controller.
Recommended Action
If you see this fault, take the following actions:
Step 1 Monitor the fan status.
Step 2 If the problem persists for a long period of time or if other fans do not show the same problem, reseat the fan.
Step 3 If the above actions did not resolve the issue, create a show tech-support file for the chassis and contact Cisco TAC.
Fault Details
Cause: performance-problem
mibFaultName: fltEquipmentFanPerfThresholdCritical
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/fex-[id]/fan-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]
fltEquipmentFanPerfThresholdNonRecoverable
Fault Code: F0397
Message
Fan [id] in Fan Module [tray]-[id] under chassis [id] speed: [perf]Fan [id] in fabric interconnect [id] speed: [perf]Fan [id] in Fan Module [tray]-[id] under server [id] speed: [perf]
Explanation
This fault occurs when the fan speed read from the fan controller has far exceeded the desired fan speed. It frequently indicates that the fan has failed.
Recommended Action
If you see this fault, take the following actions:
Step 1 Replace the fan.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: performance-problem
mibFaultName: fltEquipmentFanPerfThresholdNonRecoverable
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/fex-[id]/fan-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]
fltEquipmentIOCardFirmwareUpgrade
Fault Code: F0398
Message
Chassis controller in IOM [chassisId]/[id] ([switchId]) firmware upgrade problem: [upgradeStatus]
Explanation
This fault typically occurs when an IOM upgrade fails.
Recommended Action
If you see this fault, take the following actions:
Step 1 On the FSM tab for the IOM, verify whether FSM for the upgrade completed successfully or failed.
Step 2 If the FSM failed, review the error message in the FSM.
Step 3 If the error message is self explanatory, verify the physical connectivity. For example, an error message could be No Connection to Endpoint or Link Down.
Step 4 If the above action did not resolve the issue and the fault persists, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: firmware-upgrade-problem
mibFaultName: fltEquipmentIOCardFirmwareUpgrade
moClass: equipment:IOCard
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltEquipmentChassisUnsupportedConnectivity
Fault Code: F0399
Message
Current connectivity for chassis [id] does not match discovery policy: [configState]
Explanation
This fault typically occurs when the current connectivity for a chassis does not match the configuration in the chassis discovery policy.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the correct number of links are configured in the chassis discovery policy.
Step 2 Check the state of the I/O module links.
Step 3 Reacknowledge the chassis.
Step 4 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: unsupported-connectivity-configuration
mibFaultName: fltEquipmentChassisUnsupportedConnectivity
moClass: equipment:Chassis
Affected MO: sys/chassis-[id]
fltEquipmentChassisUnacknowledged
Fault Code: F0400
Message
Chassis [id] connectivity configuration: [configState]
Explanation
This fault typically occurs when or more of the I/O module links from the chassis are unacknowledged.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the state of the I/O module links.
Step 2 Reacknowledge the chassis.
Step 3 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-unacknowledged
mibFaultName: fltEquipmentChassisUnacknowledged
moClass: equipment:Chassis
Affected MO: sys/chassis-[id]
fltEquipmentIOCardUnsupportedConnectivity
Fault Code: F0401
Message
IOM [chassisId]/[id] ([switchId]) current connectivity does not match discovery policy or connectivity is unsupported: [configState]
Explanation
This fault typically occurs when the current connectivity for an I/O module does not match the configuration in the chassis discovery policy.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the correct number of links are configured in the chassis discovery policy.
Step 2 Check the state of the I/O module links.
Step 3 Note that atleast 2 links are required to be connected between FEX and 61xx Fabric Interconnect
Step 4 Reacknowledge the chassis.
Step 5 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: unsupported-connectivity-configuration
mibFaultName: fltEquipmentIOCardUnsupportedConnectivity
moClass: equipment:IOCard
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltEquipmentIOCardUnacknowledged
Fault Code: F0402
Message
IOM [chassisId]/[id] ([switchId]) connectivity configuration: [configState]
Explanation
This fault typically occurs when an I/O module is unacknowledged.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the state of the I/O module links.
Step 2 Reacknowledge the chassis.
Step 3 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-unacknowledged
mibFaultName: fltEquipmentIOCardUnacknowledged
moClass: equipment:IOCard
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltEquipmentIOCardPeerDisconnected
Fault Code: F0403
Message
IOM [chassisId]/[id] ([switchId]) peer connectivity: [peerCommStatus]
Explanation
This fault typically occurs when an I/O module is unable to communicate with its peer I/O module.
Recommended Action
If you see this fault, take the following actions:
Step 1 Wait a few minutes to see if the fault clears. This is typically a temporary issue, and can occur after a firmware upgrade.
Step 2 If the fault does not clear after a few minutes, remove and reinsert the I/O module.
Step 3 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-disconnected
mibFaultName: fltEquipmentIOCardPeerDisconnected
moClass: equipment:IOCard
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltEquipmentChassisIdentity
Fault Code: F0404
Message
Chassis [id] has a mismatch between FRU identity reported by Fabric/IOM vs. FRU identity reported by CMC
Explanation
This fault typically occurs when the FRU information for an I/O module is corrupted or malformed.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the capability catalog in Cisco FPR Manager is up to date. If necessary, update the catalog.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentChassisIdentity
moClass: equipment:Chassis
Affected MO: sys/chassis-[id]
fltEquipmentIOCardIdentity
Fault Code: F0405
Message
[side] IOM [chassisId]/[id] ([switchId]) has a malformed FRU
Explanation
This fault typically occurs when the FRU information for an I/O module is corrupted or malformed.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the capability catalog in Cisco FPR Manager is up to date. If necessary, update the catalog.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentIOCardIdentity
moClass: equipment:IOCard
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltEquipmentFanModuleIdentity
Fault Code: F0406
Message
Fan Module [tray]-[id] in chassis [id] has a malformed FRUFan Module [tray]-[id] in server [id] has a malformed FRUFan Module [tray]-[id] in fabric interconnect [id] has a malformed FRU
Explanation
This fault typically occurs when the FRU information for a fan module is corrupted or malformed.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the capability catalog in Cisco FPR Manager is up to date. If necessary, update the catalog.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentFanModuleIdentity
moClass: equipment:FanModule
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]
fltEquipmentPsuIdentity
Fault Code: F0407
Message
Power supply [id] on chassis [id] has a malformed FRUPower supply [id] on server [id] has a malformed FRU
Explanation
This fault typically occurs when the FRU information for a power supply unit is corrupted or malformed.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the capability catalog in Cisco FPR Manager is up to date. If necessary, update the catalog.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentPsuIdentity
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentChassisPowerProblem
Fault Code: F0408
Message
Power state on chassis [id] is [power]
Explanation
This fault typically occurs when the chassis fails to meet the minimal power requirements defined in the power policy or when one or more power supplies have failed.
Recommended Action
If you see this fault, take the following actions:
Step 1 In Cisco FPR Manager, verify that all PSUs for the chassis are functional.
Step 2 Verify that all PSUs are seated properly within the chassis and are powered on.
Step 3 Physically unplug and replug the power cord into the chassis.
Step 4 If all PSUs are operating at maximum capacity, either add more PSUs to the chassis or redefine the power policy in Cisco FPR Manager.
Step 5 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentChassisPowerProblem
moClass: equipment:Chassis
Affected MO: sys/chassis-[id]
fltEquipmentChassisThermalThresholdCritical
Fault Code: F0409
Message
Thermal condition on chassis [id]. [thermalStateQualifier]
Explanation
This fault occurs under the following conditions:
Step 1 If a component within a chassis is operating outside the safe thermal operating range.
Step 2 If the chassis controller in the supervisor is unable to determine the thermal condition of a blade server, the show tech-support file for the chassis provides a more detailed report of the most severe thermal conditions currently applicable for that chassis.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the temperature readings for the blade servers and supervisor and ensure they are within the recommended thermal safe operating range.
Step 2 If the fault reports a "Thermal Sensor threshold crossing in blade" error for one or more blade servers, check if DIMM or processor temperature related faults have been raised against that blade.
Step 3 If the fault reports a "Thermal Sensor threshold crossing in supervisor" error for supervisor, check if thermal faults have been raised against that supervisor. Those faults include details of the thermal condition.
Step 4 If the fault reports a "Missing or Faulty Fan" error, check on the status of that fan. If it needs replacement, create a show tech-support file for the chassis and contact Cisco TAC.
Step 5 If the fault reports a "No connectivity between supervisor and blade" or "Thermal Sensor readings unavailable from blade" error, check if that blade server is operational and whether any faults have been raised against that blade server. In this situation, the chassis controller may go into a fail-safe operating mode and the fan speeds may increase as a precautionary measure.
Step 6 If the above actions did not resolve the issue and the condition persists, create a show tech-support file for Cisco FPR Manager and the chassis and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentChassisThermalThresholdCritical
moClass: equipment:Chassis
Affected MO: sys/chassis-[id]
fltEquipmentChassisThermalThresholdNonRecoverable
Fault Code: F0411
Message
Thermal condition on chassis [id]. [thermalStateQualifier]
Explanation
FPRM raises this fault under the following conditions:
Step 1 If a component within a chassis is operating outside the safe thermal operating range.
Step 2 If the chassis controller in the supervisor is unable to determine the thermal condition of a blade server, the show tech-support file for the chassis provides a more detailed report of the most severe thermal conditions currently applicable for that chassis.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the temperature readings for the blade servers and supervisor and ensure they are within the recommended thermal safe operating range.
Step 2 If the fault reports a "Thermal Sensor threshold crossing in blade" error for one or more blade servers, check if DIMM or processor temperature related faults have been raised against that blade.
Step 3 If the fault reports a "Thermal Sensor threshold crossing in supervisor" error for supervisor, check if thermal faults have been raised against that supervisor. Those faults include details of the thermal condition.
Step 4 If the fault reports a "Missing or Faulty Fan" error, check on the status of that fan. If it needs replacement, create a show tech-support file for the chassis and contact Cisco TAC.
Step 5 If the fault reports a "No connectivity between supervisor and blade" or "Thermal Sensor readings unavailable from blade" error, check if that blade server is operational and whether any faults have been raised against that blade server. In this situation, the chassis controller may go into a fail-safe operating mode and the fan speeds may increase as a precautionary measure.
Step 6 If the above actions did not resolve the issue and the condition persists, create a show tech-support file for Cisco FPR Manager and the chassis and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentChassisThermalThresholdNonRecoverable
moClass: equipment:Chassis
Affected MO: sys/chassis-[id]
fltComputeBoardCmosVoltageThresholdCritical
Fault Code: F0424
Message
Possible loss of CMOS settings: CMOS battery voltage on server [chassisId]/[slotId] is [cmosVoltage]Possible loss of CMOS settings: CMOS battery voltage on server [id] is [cmosVoltage]
Explanation
This fault is raised when the CMOS battery voltage has dropped to lower than the normal operating range. This could impact the clock and other CMOS settings.
Recommended Action
If you see this fault, replace the battery.
Fault Details
mibFaultName: fltComputeBoardCmosVoltageThresholdCritical
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/rack-unit-[id]/board
fltComputeBoardCmosVoltageThresholdNonRecoverable
Fault Code: F0425
Message
Possible loss of CMOS settings: CMOS battery voltage on server [chassisId]/[slotId] is [cmosVoltage]Possible loss of CMOS settings: CMOS battery voltage on server [id] is [cmosVoltage]
Explanation
This fault is raised when the CMOS battery voltage has dropped quite low and is unlikely to recover. This impacts the clock and other CMOS settings.
Recommended Action
If you see this fault, replace the battery.
Fault Details
mibFaultName: fltComputeBoardCmosVoltageThresholdNonRecoverable
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/rack-unit-[id]/board
fltMgmtEntityElection-failure
Fault Code: F0428
Message
Fabric Interconnect [id], election of primary managemt instance has failed
Explanation
This fault occurs in an unlikely event that the fabric interconnects in a cluster configuration could not reach an agreement for selecting the primary fabric interconnect. This impacts the full HA functionality of the fabric interconnect cluster.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the initial setup configuration is correct on both fabric interconnects.
Step 2 Verify that the L1 and L2 links are properly connected between the fabric interconnects.
Step 3 In the Cisco FPR Manager CLI, run the cluster force primary local-mgmt command on one fabric interconnect.
Step 4 Reboot the fabric interconnects.
Step 5 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltMgmtEntityElectionFailure
Affected MO: sys/mgmt-entity-[id]
fltMgmtEntityHa-not-ready
Fault Code: F0429
Message
Fabric Interconnect [id], HA functionality not ready
Explanation
This fault occurs if Cisco FPR Manager cannot discover or communicate with one or more chassis or rack servers to write the HA Cluster state. This impacts the full HA functionality of the fabric interconnect cluster.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the initial setup configuration is correct on both fabric interconnects.
Step 2 Verify that the L1 and L2 links are properly connected between the fabric interconnects.
Step 3 Verify that the IOMs and/or FEXes are reachable and the server ports are enabled and operationally up.
Step 4 Verify that the chassis and/or rack servers are powered up and reachable
Step 5 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltMgmtEntityHaNotReady
Affected MO: sys/mgmt-entity-[id]
fltMgmtEntityVersion-incompatible
Fault Code: F0430
Message
Fabric Interconnect [id], management services, incompatible versions
Explanation
This fault occurs if the Cisco FPR Manager software on the subordinate fabric interconnect is not the same release as that of the primary fabric interconnect. This impacts the full HA functionality of the fabric interconnect cluster.
Recommended Action
If you see this fault, take the following actions:
Step 1 Upgrade the Cisco FPR Manager software on the subordinate fabric interconnect to the same release as the primary fabric interconnect and verify that both fabric interconnects are running the same release of Cisco FPR Manager.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: version-incompatible
mibFaultName: fltMgmtEntityVersionIncompatible
Affected MO: sys/mgmt-entity-[id]
fltEquipmentFanMissing
Fault Code: F0434
Message
Fan [id] in fabric interconnect [id] presence: [presence]Fan [id] in fex [id] presence: [presence]Fan [id] in Fan Module [tray]-[id] under server [id] presence: [presence]
Explanation
This fault occurs in the unlikely event that a fan in a fan module cannot be detected.
Recommended Action
If you see this fault, take the following actions:
Step 1 Insert/reinsert the fan module in the slot that is reporting the issue.
Step 2 Replace the fan module with a different fan module, if available.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentFanMissing
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/fex-[id]/fan-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]
fltEquipmentIOCardAutoUpgradingFirmware
Fault Code: F0435
Message
IOM [chassisId]/[id] ([switchId]) is auto upgrading firmware
Explanation
This fault typically occurs when an I/O module is auto upgrading. Auto-upgrade occurs when the firmware version on the IOM is incompatible with the firmware version on the fabric interconnect.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the IOM and fabric interconnects are not running the same firmware version, wait for the auto-upgrade to complete.
Step 2 When the IOM upgrade is completed, verify that Cisco FPR Manager has cleared this fault.
Step 3 If you see this fault after the IOM overall status changes to operable, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: auto-firmware-upgrade
mibFaultName: fltEquipmentIOCardAutoUpgradingFirmware
moClass: equipment:IOCard
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltFirmwarePackItemImageMissing
Fault Code: F0436
Message
[type] image with vendor [hwVendor], model [hwModel] and version [version] is deleted
Explanation
This fault typically occurs when the image to which a firmware package item refers is missing.
Recommended Action
If you see this fault, take the following actions:
Step 1 In Cisco FPR Manager GUI, navigate to the Firmware Management Images tab and determine whether the missing image is available or not.
Step 2 If the image is present, click on it to verify the model and vendor.
Step 3 If the image for the required model and vendor is not present, download that image or bundle from the Cisco.com website.
Step 4 If the image is present and the fault persists, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFirmwarePackItemImageMissing
moClass: firmware:PackItem
Affected MO: org-[name]/fw-catalog-pack-[name]/pack-image-[hwVendor]|[hwModel]|[type]
Affected MO: org-[name]/fw-host-pack-[name]/pack-image-[hwVendor]|[hwModel]|[type]
Affected MO: org-[name]/fw-infra-pack-[name]/pack-image-[hwVendor]|[hwModel]|[type]
Affected MO: org-[name]/fw-mgmt-pack-[name]/pack-image-[hwVendor]|[hwModel]|[type]
Affected MO: org-[name]/fw-platform-pack-[name]/pack-image-[hwVendor]|[hwModel]|[type]
Affected MO: org-[name]/pack-image-[hwVendor]|[hwModel]|[type]
fltEtherSwitchIntFIoSatellite-wiring-numbers-unexpected
Fault Code: F0440
Message
Chassis discovery policy conflict: Link IOM [chassisId]/[slotId]/[portId] to fabric interconnect [switchId]:[peerSlotId]/[peerPortId] not configured
Explanation
The configuration of the chassis discovery policy conflicts with the physical IOM uplinks. Cisco FPR Manager raises this fault when the chassis discovery policy is configured for more links than are physically cabled between the IOM uplinks on the chassis and the fabric interconnect.
Recommended Action
If you see this fault, take the following actions:
Step 1 Ensure that you cable at least the same number of IOM uplinks as are configured in the chassis discovery policy, and that you configure the corresponding server ports on the fabric interconnect.
Step 2 Reacknowledge the chassis.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: unexpected-number-of-links
mibFaultName: fltEtherSwitchIntFIoSatelliteWiringNumbersUnexpected
moClass: ether:SwitchIntFIo
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]
fltMgmtEntityManagement-services-failure
Fault Code: F0451
Message
Fabric Interconnect [id], management services have failed
Explanation
This fault occurs in an unlikely event that management services fail on a fabric interconnect. This impacts the full HA functionality of the fabric interconnect cluster.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the initial setup configuration is correct on both fabric interconnects.
Step 2 Verify that the L1 and L2 links are properly connected between the fabric interconnects.
Step 3 Reboot the fabric interconnects.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: management-services-failure
mibFaultName: fltMgmtEntityManagementServicesFailure
Affected MO: sys/mgmt-entity-[id]
fltMgmtEntityManagement-services-unresponsive
Fault Code: F0452
Message
Fabric Interconnect [id], management services are unresponsive
Explanation
This fault occurs when management services on a fabric interconnect are unresponsive. This impacts the full HA functionality of the fabric interconnect cluster.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the initial setup configuration is correct on both fabric interconnects.
Step 2 Verify that the L1 and L2 links are properly connected between the fabric interconnects.
Step 3 Reboot the fabric interconnects.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: management-services-unresponsive
mibFaultName: fltMgmtEntityManagementServicesUnresponsive
Affected MO: sys/mgmt-entity-[id]
fltEquipmentChassisInoperable
Fault Code: F0456
Message
Chassis [id] operability: [operability]
Explanation
This fault typically occurs for one of the following reasons:
- The fabric interconnect cannot communicate with a chassis. For a cluster configuration, this fault means that neither fabric interconnect can communicate with the chassis.
- The chassis has an invalid FRU.
Recommended Action
If you see this fault, take the following actions:
Step 1 In Cisco FPR Manager, reacknowledge the chassis that raised the fault.
Step 2 Physically unplug and replug the power cord into the chassis.
Step 3 Verify that the I/O modules are functional.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inoperable
mibFaultName: fltEquipmentChassisInoperable
moClass: equipment:Chassis
Affected MO: sys/chassis-[id]
fltEtherServerIntFIoHardware-failure
Fault Code: F0458
Message
IOM [transport] interface [portId] on chassis [id] oper state: [operState], reason: [stateQual]Fabric Interconnect [transport] interface [portId] on fabric interconnect [id] oper state: [operState], reason: [stateQual]IOM [transport] interface [portId] on fex [id] oper state: [operState], reason: [stateQual]
Explanation
This fault is raised on the IOM/FEX backplane ports when Cisco FPR Manager detects a hardware failure.
Recommended Action
If you see this fault, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEtherServerIntFIoHardwareFailure
moClass: ether:ServerIntFIo
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/rack-unit-[id]/diag/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]
fltDcxVcMgmt-vif-down
Fault Code: F0459
Message
IOM [chassisId] / [slotId] ([switchId]) management VIF [id] down, reason [stateQual]
Explanation
This fault occurs when the transport VIF for an I/O module is down. Cisco FPR Manager raises this fault when a fabric interconnect reports the connectivity state on virtual interface as one of the following:
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the chassis discovery has gone through successfully. Check the states on all communicating ports from end to end.
Step 2 If connectivity seems correct, decommission and recommission the chassis.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltDcxVcMgmtVifDown
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/fex-[id]/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/fex-[id]/fabric-[switchId]/vc-[id]
Affected MO: sys/fex-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/fex-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/vc-[id]
Affected MO: sys/switch-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/switch-[id]/mgmt/fabric-[switchId]/vc-[id]
fltSysdebugMEpLogMEpLogLog
Fault Code: F0460
Message
Log capacity on [side] IOM [chassisId]/[id] is [capacity]Log capacity on Management Controller on server [chassisId]/[slotId] is [capacity]Log capacity on Management Controller on server [id] is [capacity]
Explanation
This fault typically occurs because Cisco FPR Manager has detected that the system event log (SEL) on the server is approaching full capacity. The available capacity in the log is low. This is an info-level fault and can be ignored if you do not want to clear the SEL at this time.
Recommended Action
If you see this fault, you can clear the SEL in Cisco FPR Manager if desired.
Fault Details
mibFaultName: fltSysdebugMEpLogMEpLogLog
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/fex-[id]/mgmt/log-[type]-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/mgmt/log-[type]-[id]
Affected MO: sys/switch-[id]/mgmt/log-[type]-[id]
fltSysdebugMEpLogMEpLogVeryLow
Fault Code: F0461
Message
Log capacity on [side] IOM [chassisId]/[id] is [capacity]Log capacity on Management Controller on server [chassisId]/[slotId] is [capacity]Log capacity on Management Controller on server [id] is [capacity]
Explanation
This fault typically occurs because Cisco FPR Manager has detected that the system event log (SEL) on the server is almost full. The available capacity in the log is very low. This is an info-level fault and can be ignored if you do not want to clear the SEL at this time.
Recommended Action
If you see this fault, you can clear the SEL in Cisco FPR Manager if desired.
Fault Details
mibFaultName: fltSysdebugMEpLogMEpLogVeryLow
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/fex-[id]/mgmt/log-[type]-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/mgmt/log-[type]-[id]
Affected MO: sys/switch-[id]/mgmt/log-[type]-[id]
fltSysdebugMEpLogMEpLogFull
Fault Code: F0462
Message
Log capacity on [side] IOM [chassisId]/[id] is [capacity]Log capacity on Management Controller on server [chassisId]/[slotId] is [capacity]Log capacity on Management Controller on server [id] is [capacity]
Explanation
This fault typically occurs because Cisco FPR Manager could not transfer the SEL file to the location specified in the SEL policy. This is an info-level fault and can be ignored if you do not want to clear the SEL at this time.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify the configuration of the SEL policy to ensure that the location, user, and password provided are correct.
Step 2 If you do want to transfer and clear the SEL and the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltSysdebugMEpLogMEpLogFull
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/fex-[id]/mgmt/log-[type]-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/mgmt/log-[type]-[id]
Affected MO: sys/switch-[id]/mgmt/log-[type]-[id]
fltComputePoolEmpty
Fault Code: F0463
Message
server pool [name] is empty
Explanation
This fault typically occurs when the selected server pool does not contain any servers.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify the qualifier settings in the server pool policy qualifications. If the policy was modified after the server was discovered, reacknowledge the server.
Step 2 Manually associate the service profile with a server.
Step 3 If the server pool is not used, ignore the fault.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltComputePoolEmpty
Affected MO: org-[name]/compute-pool-[name]
fltUuidpoolPoolEmpty
Fault Code: F0464
Message
UUID suffix pool [name] is empty
Explanation
This fault typically occurs when a UUID suffix pool does not contain any UUID suffixes.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the pool is in use, add a block of UUID suffixes to the pool.
Step 2 If the pool is not in use, ignore the fault.
Fault Details
mibFaultName: fltUuidpoolPoolEmpty
Affected MO: org-[name]/uuid-pool-[name]
fltIppoolPoolEmpty
Fault Code: F0465
Message
IP pool [name] is empty
Explanation
This fault typically occurs when an IP address pool does not contain any IP addresses.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the pool is in use, add a block of IP addresses to the pool.
Step 2 If the pool is not in use, ignore the fault.
Fault Details
mibFaultName: fltIppoolPoolEmpty
Affected MO: fabric/lan/network-sets/ip-pool-[name]
Affected MO: org-[name]/ip-pool-[name]
fltMacpoolPoolEmpty
Fault Code: F0466
Message
MAC pool [name] is empty
Explanation
This fault typically occurs when a MAC address pool does not contain any MAC addresses.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the pool is in use, add a block of MAC addresses to the pool.
Step 2 If the pool is not in use, ignore the fault.
Fault Details
mibFaultName: fltMacpoolPoolEmpty
Affected MO: org-[name]/mac-pool-[name]
fltFirmwareUpdatableImageUnusable
Fault Code: F0470
Message
backup image is unusable. reason: [operStateQual]
Explanation
This fault typically occurs when the backup firmware image on an endpoint is unusable.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the fault and the error message on the FSM tab for the endpoint to determine why the firmware image is unusable.
Step 2 If the firmware image is bad or corrupted, download another copy from the Cisco website and update the backup version on the endpoint with the new image.
Step 3 If the image is present and the fault persists, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFirmwareUpdatableImageUnusable
moClass: firmware:Updatable
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/blade-[slotId]/bios/fw-updatable
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/bios/fw-updatable
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/blade-[slotId]/os-ctrl/fw-updatable
Affected MO: sys/chassis-[id]/epmfpga-[slot]/fw-updatable
Affected MO: sys/chassis-[id]/fpga/fw-updatable
Affected MO: sys/chassis-[id]/rommon/fw-updatable
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/fw-updatable
Affected MO: sys/fex-[id]/mgmt/fw-updatable
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fw-updatable
Affected MO: sys/mgmt/fw-updatable
Affected MO: sys/os-ctrl/fw-updatable
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fw-updatable
Affected MO: sys/rack-unit-[id]/bios/fw-updatable
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fw-updatable
Affected MO: sys/rack-unit-[id]/ext-board-[id]/bios/fw-updatable
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fw-updatable
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fw-updatable
Affected MO: sys/rack-unit-[id]/mgmt/fw-updatable
Affected MO: sys/rack-unit-[id]/os-ctrl/fw-updatable
Affected MO: sys/switch-[id]/mgmt/fw-updatable
fltFirmwareBootUnitCantBoot
Fault Code: F0471
Message
unable to boot the startup image. End point booted with backup image
Explanation
This fault typically occurs when the startup firmware image on an endpoint is corrupted or invalid, and the endpoint cannot boot from that image.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the fault and the error message on the FSM tab for the endpoint to determine why the firmware image is unusable. The error message usually includes an explanation for why the endpoint could not boot from the startup image, such as Bad-Image or Checksum Failed.
Step 2 If the firmware image is bad or corrupted, download another copy from the Cisco website and update the startup version on the endpoint with the new image.
Step 3 If the fault persists, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFirmwareBootUnitCantBoot
moClass: firmware:BootUnit
Affected MO: capabilities/ep/mgmt-ext/fw-boot-def/bootunit-[type]
Affected MO: capabilities/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/graphics-card-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/os-ctrl/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/epmfpga-[slot]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/fpga/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/rommon/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/fex-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/os-ctrl/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/graphics-card-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/os-ctrl/fw-boot-def/bootunit-[type]
Affected MO: sys/switch-[id]/mgmt/fw-boot-def/bootunit-[type]
fltFcpoolInitiatorsEmpty
Fault Code: F0476
Message
FC pool [purpose] [name] is empty
Explanation
This fault typically occurs when a WWN pool does not contain any WWNs.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the pool is in use, add a block of WWNs to the pool.
Step 2 If the pool is not in use, ignore the fault.
Fault Details
mibFaultName: fltFcpoolInitiatorsEmpty
moClass: fcpool:Initiators
Affected MO: org-[name]/wwn-pool-[name]
fltEquipmentIOCardInaccessible
Fault Code: F0478
Message
[side] IOM [chassisId]/[id] ([switchId]) is inaccessible
Explanation
This fault typically occurs because an I/O module has lost its connection to the fabric interconnects. In a cluster configuration, the chassis fails over to the other I/O module. For a standalone configuration, the chassis associated with the I/O module loses network connectivity. This is a critical fault because it can result in the loss of network connectivity and disrupt data traffic through the I/O module.
Recommended Action
If you see this fault, take the following actions:
Step 1 Wait a few minutes to see if the fault clears. This is typically a temporary issue, and can occur after a firmware upgrade.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inaccessible
mibFaultName: fltEquipmentIOCardInaccessible
moClass: equipment:IOCard
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltDcxVIfLinkState
Fault Code: F0479
Message
Virtual interface [id] link state is down
Explanation
This fault occurs when Cisco FPR cannot send or receive data through an uplink port.
Recommended Action
If you see this fault, take the following actions:
Step 1 Reenable the uplink port that failed.
Step 2 Check the associated port to ensure it is in up state.
Step 3 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltDcxVIfLinkState
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/vif-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/fcoe/vif-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vif-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fcoe/vif-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/vif-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vif-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/vif-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/fcoe/vif-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vif-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fcoe/vif-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/vif-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vif-[id]
fltEquipmentFanModuleDegraded
Fault Code: F0480
Message
Fan module [tray]-[id] in chassis [id] operability: [operability]Fan module [tray]-[id] in server [id] operability: [operability]Fan module [tray]-[id] in fabric interconnect [id] operability: [operability]
Explanation
This fault occurs when a fan module is not operational.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the fan module.
Step 2 Review the Cisco FPR Site Preparation Guide to ensure the fan module has adequate airflow, including front and back clearance.
Step 3 Verify that the air flows for the fan module are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 8 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-degraded
mibFaultName: fltEquipmentFanModuleDegraded
moClass: equipment:FanModule
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]
fltEquipmentIOCardPost-failure
Fault Code: F0481
Message
[side] IOM [chassisId]/[id] ([switchId]) POST failure
Explanation
This fault typically occurs when an I/O module encounters errors during the Power On Self Test (POST). The impact of this fault varies according to the errors that were encountered during POST.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the POST results for the I/O module. In Cisco FPR Manager GUI, you can access the POST results from the General tab for the I/O module. In Cisco FPR Manager CLI, you can access the POST results through the show post command under the scope for the I/O module.
Step 2 If the POST results indicate FRU error, check if FPR manager has raised fault for the FRU and follow recommended action for the fault.
Step 3 Otherwise, reboot the I/O module.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentIOCardPostFailure
moClass: equipment:IOCard
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltEquipmentFanPerfThresholdLowerNonRecoverable
Fault Code: F0484
Message
Fan [id] in Fan Module [tray]-[id] under chassis [id] speed: [perf]Fan [id] in fabric interconnect [id] speed: [perf]Fan [id] in Fan Module [tray]-[id] under server [id] speed: [perf]
Explanation
This fault occurs when the fan speed reading from the fan controller is far below the desired fan speed, and the fan has likely failed.
Recommended Action
If you see this fault, create a detailed show tech-support file for the chassis and replace the fan module. If necessary, contact Cisco TAC.
Fault Details
Cause: performance-problem
mibFaultName: fltEquipmentFanPerfThresholdLowerNonRecoverable
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/fex-[id]/fan-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]
fltComputePhysicalPost-failure
Fault Code: F0517
Message
Server [id] POST or diagnostic failureServer [chassisId]/[slotId] POST or diagnostic failure
Explanation
This fault typically occurs when the server has encountered a diagnostic failure or an error during POST.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the POST results for the server. In Cisco FPR Manager GUI, you can access the POST results from the General tab for the server. In Cisco FPR Manager CLI, you can access the POST results through the show post command under the scope for the server.
Step 2 Reboot the server.
Step 3 If the above actions did not resolve the issue, execute the show tech-support command and contact Cisco Technical Support.
Fault Details
mibFaultName: fltComputePhysicalPostFailure
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/rack-unit-[id]
fltEquipmentPsuOffline
Fault Code: F0528
Message
Power supply [id] in chassis [id] power: [power]Power supply [id] in fabric interconnect [id] power: [power]Power supply [id] in fex [id] power: [power]Power supply [id] in server [id] power: [power]
Explanation
This fault typically occurs when Cisco FPR Manager detects that a power supply unit in a chassis, fabric interconnect, or FEX is offline.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the power cord is properly connected to the PSU and the power source.
Step 2 Verify that the power source is 220 volts.
Step 3 Verify that the PSU is properly installed in the chassis or fabric interconnect.
Step 4 Remove the PSU and reinstall it.
Step 5 Replace the PSU.
Step 6 If the above actions did not resolve the issue, note down the type of PSU, execute the show tech-support command, and contact Cisco Technical Support.
Fault Details
mibFaultName: fltEquipmentPsuOffline
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltStorageRaidBatteryInoperable
Fault Code: F0531
Message
RAID Battery on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]RAID Battery on server [id] operability: [operability]. Reason: [operQualifierReason]
Explanation
This fault occurs when the RAID backup unit is not operational.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the backup unit is a battery, replace the battery.
Step 2 If the backup unit is a supercapacitor type and the supercapacitor is missing, verify its presence and supply if missing.
Step 3 If the backup unit is a supercapacitor type and the TFM is missing, verify its presence and supply if missing.
Step 4 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inoperable
mibFaultName: fltStorageRaidBatteryInoperable
moClass: storage:RaidBattery
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/raid-battery
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/raid-battery
fltSysdebugMEpLogTransferError
Fault Code: F0532
Message
Server [chassisId]/[slotId] [type] transfer failed: [operState]Server [id] [type] transfer failed: [operState]
Explanation
This fault occurs when the transfer of a managed endpoint log file, such as the SEL, fails.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the fault is related to the SEL, verify the connectivity to the CIMC on the server.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: file-transfer-failed
mibFaultName: fltSysdebugMEpLogTransferError
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/fex-[id]/mgmt/log-[type]-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/mgmt/log-[type]-[id]
Affected MO: sys/switch-[id]/mgmt/log-[type]-[id]
fltComputeRtcBatteryInoperable
Fault Code: F0533
Message
RTC Battery on server [chassisId]/[slotId] operability: [operability]
Explanation
This fault is raised when the CMOS battery voltage is below the normal operating range. This impacts the system clock.
Recommended Action
If you see this fault, replace the CMOS battery.
Fault Details
Cause: equipment-inoperable
mibFaultName: fltComputeRtcBatteryInoperable
moClass: compute:RtcBattery
Affected MO: sys/chassis-[id]/blade-[slotId]/board/rtc-battery
Affected MO: sys/rack-unit-[id]/board/rtc-battery
fltMemoryBufferUnitThermalThresholdNonCritical
Fault Code: F0535
Message
Buffer Unit [id] on server [chassisId]/[slotId] temperature: [thermal]Buffer Unit [id] on server [id] temperature: [thermal]
Explanation
This fault occurs when the temperature of a memory buffer unit on a blade or rack server exceeds a non-critical threshold value, but is still below the critical threshold. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
- If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the server.
Step 2 Review the Cisco FPR Site Preparation Guide to ensure the servers have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco FPR chassis or rack server are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 8 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltMemoryBufferUnitThermalThresholdNonCritical
moClass: memory:BufferUnit
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sensor-unit-[id]
Affected MO: sys/rack-unit-[id]/board/sensor-unit-[id]
fltMemoryBufferUnitThermalThresholdCritical
Fault Code: F0536
Message
Buffer Unit [id] on server [chassisId]/[slotId] temperature: [thermal]Buffer Unit [id] on server [id] temperature: [thermal]
Explanation
This fault occurs when the temperature of a memory buffer unit on a blade or rack server exceeds a critical threshold value. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
- If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the server.
Step 2 Review the Cisco FPR Site Preparation Guide to ensure the servers have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco FPR chassis or rack server are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 8 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltMemoryBufferUnitThermalThresholdCritical
moClass: memory:BufferUnit
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sensor-unit-[id]
Affected MO: sys/rack-unit-[id]/board/sensor-unit-[id]
fltMemoryBufferUnitThermalThresholdNonRecoverable
Fault Code: F0537
Message
Buffer Unit [id] on server [chassisId]/[slotId] temperature: [thermal]Buffer Unit [id] on server [id] temperature: [thermal]
Explanation
This fault occurs when the temperature of a memory buffer unit on a blade or rack server has been out of the operating range, and the issue is not recoverable. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
- If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the server.
Step 2 Review the Cisco FPR Site Preparation Guide to ensure the servers have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco FPR chassis or rack server are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 8 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltMemoryBufferUnitThermalThresholdNonRecoverable
moClass: memory:BufferUnit
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sensor-unit-[id]
Affected MO: sys/rack-unit-[id]/board/sensor-unit-[id]
fltComputeIOHubThermalNonCritical
Fault Code: F0538
Message
IO Hub on server [chassisId]/[slotId] temperature: [thermal]
Explanation
This fault is raised when the IO controller temperature is outside the upper or lower non-critical threshold.
Recommended Action
If you see this fault, monitor other environmental events related to this server and ensure the temperature ranges are within recommended ranges.
Fault Details
mibFaultName: fltComputeIOHubThermalNonCritical
Affected MO: sys/chassis-[id]/blade-[slotId]/board/iohub
Affected MO: sys/rack-unit-[id]/board/iohub
fltComputeIOHubThermalThresholdCritical
Fault Code: F0539
Message
IO Hub on server [chassisId]/[slotId] temperature: [thermal]
Explanation
This fault is raised when the IO controller temperature is outside the upper or lower critical threshold.
Recommended Action
If you see this fault, take the following actions:
Step 1 Monitor other environmental events related to the server and ensure the temperature ranges are within recommended ranges.
Step 2 Consider turning off the server for a while if possible.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltComputeIOHubThermalThresholdCritical
Affected MO: sys/chassis-[id]/blade-[slotId]/board/iohub
Affected MO: sys/rack-unit-[id]/board/iohub
fltComputeIOHubThermalThresholdNonRecoverable
Fault Code: F0540
Message
IO Hub on server [chassisId]/[slotId] temperature: [thermal]
Explanation
This fault is raised when the IO controller temperature is outside the recoverable range of operation.
Recommended Action
If you see this fault, take the following actions:
Step 1 Shutdown the server immediately.
Step 2 Create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltComputeIOHubThermalThresholdNonRecoverable
Affected MO: sys/chassis-[id]/blade-[slotId]/board/iohub
Affected MO: sys/rack-unit-[id]/board/iohub
fltEquipmentChassisIdentity-unestablishable
Fault Code: F0543
Message
Chassis [id] has an invalid FRU
Explanation
This fault typically occurs because Cisco FPR Manager has detected an unsupported chassis. For example, the model, vendor, or revision is not recognized.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the capability catalog in Cisco FPR Manager is up to date. If necessary, update the catalog.
Step 2 If the above action did not resolve the issue, execute the show tech-support command and contact Cisco technical support.
Fault Details
Cause: identity-unestablishable
mibFaultName: fltEquipmentChassisIdentityUnestablishable
moClass: equipment:Chassis
Affected MO: sys/chassis-[id]
fltSwVlanPortNsResourceStatus
Fault Code: F0549
Message
Vlan-Port Resource exceeded
Explanation
This fault occurs when the total number of configured VLANs in the Cisco FPR instance has exceeded the allowed maximum number of configured VLANs on the fabric interconnect.
Recommended Action
If you see this fault, take the following actions:
Step 1 In the Cisco FPR Manager CLI or Cisco FPR Manager GUI, check the port VLAN count to determine by how many VLANs the system is over the maximum.
Step 2 Reduce the VLAN port count in one of the following ways:
– Delete VLANs configured on the LAN cloud.
– Delete VLANs configured on vNICs.
– Unconfigure one or more vNICs.
– Unconfigure one or more uplink Ethernet ports on the fabric interconnect.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltSwVlanPortNsResourceStatus
Affected MO: sys/switch-[id]/vlan-port-ns
fltFabricLanPinGroupEmpty
Fault Code: F0621
Message
LAN Pin Group [name] is empty
Explanation
This fault typically occurs when a LAN pin group does not contain any targets.
Recommended Action
If you see this fault, add a target to the LAN pin group.
Fault Details
mibFaultName: fltFabricLanPinGroupEmpty
moClass: fabric:LanPinGroup
Affected MO: fabric/lan/lan-pin-group-[name]
fltAdaptorExtEthIfMisConnect
Fault Code: F0625
Message
Adapter [id] eth interface [id] in server [id] mis-connected
Explanation
The link for a network-facing adapter interface is misconnected. Cisco FPR Manager raises this fault when any of the following scenarios occur:
- Cisco FPR Manager detects a new connectivity between a previously configured switch port or FEX port and the adapter’s external interface.
- Cisco FPR Manager detects a misconnected link between a fabric interconnect or FEX and its non-peer adapter’s interface.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check whether the adapter link is connected to a port that belongs to its peer fabric interconnect or FEX.
Step 2 If that connectivity seems correct, reacknowledge the server.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltAdaptorExtEthIfMisConnect
moClass: adaptor:ExtEthIf
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]
fltAdaptorHostEthIfMisConnect
Fault Code: F0626
Message
Adapter [id] eth interface [id] in server [id] mis-connected
Explanation
The link for a network-facing host interface is misconnected. Cisco FPR Manager raises this fault when any of the following scenarios occur:
- Cisco FPR Manager detects a new connectivity between a previously configured switch port and the host Ethernet interface.
- Cisco FPR Manager detects a misconnected link between the host interface and its non-peer fabric interconnect.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check whether the host Ethernet interface is connected to a port belonging to its peer fabric interconnect.
Step 2 If connectivity seems correct, reacknowledge the server.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltAdaptorHostEthIfMisConnect
moClass: adaptor:HostEthIf
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]
fltPowerBudgetPowerBudgetCmcProblem
Fault Code: F0635
Message
Power cap application failed for chassis [id]
Explanation
This fault typically occurs when the server CIMC has failed to enforce the configured power cap.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the power consumption of the chassis. If the chassis is consuming significantly more power than configured in the power cap, consider reducing the group cap so that the power consumption of other chassis consumption can be reduced to make up for the increase.
Step 2 If the above action did not resolve the issue, create a show tech-support file for Cisco FPR Manager and the chassis and then contact Cisco TAC.
Fault Details
mibFaultName: fltPowerBudgetPowerBudgetCmcProblem
Affected MO: sys/chassis-[id]/blade-[slotId]/budget
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/budget
Affected MO: sys/chassis-[id]/budget
Affected MO: sys/rack-unit-[id]/budget
Affected MO: sys/rack-unit-[id]/ext-board-[id]/budget
fltPowerBudgetPowerBudgetBmcProblem
Fault Code: F0637
Message
Power cap application failed for server [chassisId]/[slotId]Power cap application failed for server [id]
Explanation
This fault typically occurs when the server CIMC or BIOS has failed to enforce the configured power cap.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the power consumption of the blade server. If the server is consuming significantly more power than configured in the power cap, switch to a manual per blade cap configuration. If the power consumption is still too high, consider reducing the group cap so that the power consumption of other chassis consumption can be reduced to make up for the increase.
Step 2 If the power consumption is still too high, the CIMC or BIOS software is likely faulty.
Step 3 Create a show tech-support file for Cisco FPR Manager and the chassis and then contact Cisco TAC.
Fault Details
mibFaultName: fltPowerBudgetPowerBudgetBmcProblem
Affected MO: sys/chassis-[id]/blade-[slotId]/budget
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/budget
Affected MO: sys/chassis-[id]/budget
Affected MO: sys/rack-unit-[id]/budget
Affected MO: sys/rack-unit-[id]/ext-board-[id]/budget
fltPowerBudgetPowerBudgetDiscFail
Fault Code: F0640
Message
Insufficient power available to discover server [chassisId]/[slotId]Insufficient power available to discover server [id]
Explanation
This fault typically occurs when discovery fails due to unavailable power in the group.
Recommended Action
If you see this fault, take the following actions:
Step 1 Consider increasing the group cap.
Step 2 Reduce the number of blade servers or chassis in the Cisco FPR instance.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltPowerBudgetPowerBudgetDiscFail
Affected MO: sys/chassis-[id]/blade-[slotId]/budget
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/budget
Affected MO: sys/chassis-[id]/budget
Affected MO: sys/rack-unit-[id]/budget
Affected MO: sys/rack-unit-[id]/ext-board-[id]/budget
fltPowerGroupPowerGroupInsufficientBudget
Fault Code: F0642
Message
insufficient budget for power group [name]
Explanation
This fault typically occurs when the group cap is insufficient to meet the minimum hardware requirements.
Recommended Action
If you see this fault, take the following actions:
Step 1 Consider increasing the group cap.
Step 2 Reduce the number of blade servers or chassis in the Cisco FPR instance.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltPowerGroupPowerGroupInsufficientBudget
Affected MO: sys/power-ep/group-[name]
fltPowerGroupPowerGroupBudgetIncorrect
Fault Code: F0643
Message
admin committed insufficient for power group [name], using previous value [operCommitted]
Explanation
This fault typically occurs when the group cap is insufficient to meet the minimum hardware requirements. Under these circumstances, Cisco FPR Manager uses the previously entered group cap for provisioning.
Recommended Action
If you see this fault, take the following actions:
Step 1 Consider increasing the group cap.
Step 2 Reduce the number of blade servers or chassis in the Cisco FPR instance.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltPowerGroupPowerGroupBudgetIncorrect
Affected MO: sys/power-ep/group-[name]
fltMgmtIfMisConnect
Fault Code: F0688
Message
Management Port [id] in server [id] is mis connected
Explanation
This fault occurs when the server and FEX connectivity changes.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the connectivity between the server and FEX.
Step 2 If the connectivity was changed by mistake, restore it to its previous configuration.
Step 3 If the connectivity change was intentional, reacknowledge the server.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltMgmtIfMisConnect
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/if-[id]
Affected MO: sys/fex-[id]/mgmt/if-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/if-[id]
Affected MO: sys/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/if-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/mgmt/if-[id]
Affected MO: sys/switch-[id]/mgmt/if-[id]
fltLsComputeBindingAssignmentRequirementsNotMet
Fault Code: F0689
Message
Assignment of service profile [name] to server [pnDn] failed
Explanation
The server could not be assigned to the selected service profile. This fault typically occurs as a result of one of the following issues:
- The selected server does not meet the requirements of the service profile.
- If the service profile was configured for restricted migration, the selected server does not match the currently or previously assigned server.
Recommended Action
If you see this fault, select a different server that meets the requirements of the service profile or matches the currently or previously assigned server.
Fault Details
mibFaultName: fltLsComputeBindingAssignmentRequirementsNotMet
moClass: ls:ComputeBinding
Affected MO: org-[name]/ls-[name]/pn
Affected MO: org-[name]/ls-[name]/pn-req
Affected MO: org-[name]/tier-[name]/ls-[name]/pn
Affected MO: org-[name]/tier-[name]/ls-[name]/pn-req
fltEquipmentFexPost-failure
Fault Code: F0702
Message
fex [id] POST failure
Explanation
This fault typically occurs when a FEX encounters errors during the Power On Self Test (POST). The impact of this fault varies depending on which errors were encountered during POST.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the POST results for the FEX. In the Cisco FPR Manager GUI, you can access the POST results from the General tab for the FEX. In the Cisco FPR Manager CLI, you can access the POST results by entering the show post command under the scope for the FEX.
Step 2 Reboot the FEX.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentFexPostFailure
Affected MO: sys/fex-[id]
fltEquipmentFexIdentity
Fault Code: F0703
Message
Fex [id] has a malformed FRU
Explanation
This fault typically occurs when the FRU information for a FEX is corrupted or malformed.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the capability catalog in Cisco FPR Manager is up to date. If necessary, update the catalog.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentFexIdentity
Affected MO: sys/fex-[id]
fltAdaptorHostEthIfMissing
Fault Code: F0708
Message
Connection to Adapter [id] eth interface [id] in server [id] missing
Explanation
The link for a network-facing host interface is missing. Cisco FPR Manager raises this fault when it detects missing connectivity between a previously configured switch port and its previous peer host interface.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check whether the adapter link is connected to a port that belongs to its non-peer fabric interconnect.
Step 2 If that connectivity seems correct, reacknowledge the server.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltAdaptorHostEthIfMissing
moClass: adaptor:HostEthIf
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]
fltPortPIoInvalid-sfp
Fault Code: F0713
Message
[transport] port [portId] on chassis [id] role : [ifRole] transceiver type:[xcvrType][transport] port [slotId]/[aggrPortId]/[portId] on fabric interconnect [id] role : [ifRole] transceiver type:[xcvrType][transport] port [slotId]/[portId] on fabric interconnect [id] role : [ifRole] transceiver type:[xcvrType]
Explanation
This fault is raised against a fabric interconnect port, network-facing IOM port, or FEX module port if an unsupported transceiver type is inserted. The port cannot be used if it has an unsupported transceiver.
Recommended Action
If you see this fault, replace the transceiver with a supported SFP type. Refer to the documentation on the Cisco website for a list of supported SFPs.
Fault Details
Cause: unsupported-transceiver
mibFaultName: fltPortPIoInvalidSfp
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]
fltMgmtIfMissing
Fault Code: F0717
Message
Connection to Management Port [id] in server [id] is missing
Explanation
This fault occurs when the connectivity between a server and FEX is removed or unconfigured.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the connectivity between the server and FEX.
Step 2 If the connectivity was changed by mistake, restore it to its previous configuration.
Step 3 If the connectivity change was intentional, reacknowledge the server.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltMgmtIfMissing
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/if-[id]
Affected MO: sys/fex-[id]/mgmt/if-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/if-[id]
Affected MO: sys/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/if-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/mgmt/if-[id]
Affected MO: sys/switch-[id]/mgmt/if-[id]
fltFabricEthLanPcEpDown
Fault Code: F0727
Message
[type] Member [slotId]/[aggrPortId]/[portId] of Port-Channel [portId] on fabric interconnect [id] is down, membership: [membership][type] Member [slotId]/[portId] of Port-Channel [portId] on fabric interconnect [id] is down, membership: [membership]
Explanation
This fault typically occurs when a member port in an Ethernet port channel is down.
Recommended Action
If you see this fault, take the following action:
Step 1 Check the link connectivity on the upstream Ethernet switch.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFabricEthLanPcEpDown
moClass: fabric:EthLanPcEp
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
fltEquipmentIOCardThermalThresholdNonCritical
Fault Code: F0729
Message
[side] IOM [chassisId]/[id] ([switchId]) temperature: [thermal]
Explanation
This fault occurs when the temperature of an I/O module has exceeded a non-critical threshold value, but is still below the critical threshold. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
- If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the I/O module.
Step 2 Review the Cisco FPR Site Preparation Guide to ensure the chassis and I/O modules have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco FPR chassis and I/O module are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 8 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentIOCardThermalThresholdNonCritical
moClass: equipment:IOCard
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltEquipmentIOCardThermalThresholdCritical
Fault Code: F0730
Message
[side] IOM [chassisId]/[id] ([switchId]) temperature: [thermal]
Explanation
This fault occurs when the temperature of an I/O module has exceeded a critical threshold value. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
- If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the I/O module.
Step 2 Review the Cisco FPR Site Preparation Guide to ensure the chassis and I/O modules have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco FPR chassis and I/O module are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Replace the faulty I/O modules.
Step 8 Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 9 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentIOCardThermalThresholdCritical
moClass: equipment:IOCard
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltEquipmentIOCardThermalThresholdNonRecoverable
Fault Code: F0731
Message
[side] IOM [chassisId]/[id] ([switchId]) temperature: [thermal]
Explanation
This fault occurs when the temperature of an I/O module has been out of the operating range, and the issue is not recoverable. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
- If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the I/O module.
Step 2 Review the Cisco FPR Site Preparation Guide to ensure the chassis and I/O modules have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco FPR chassis and I/O module are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Replace the faulty I/O modules.
Step 8 Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 9 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentIOCardThermalThresholdNonRecoverable
moClass: equipment:IOCard
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltEquipmentChassisSeeprom-inoperable
Fault Code: F0733
Message
Device [id] SEEPROM operability: [seepromOperState]
Explanation
This fault occurs in the unlikely event that the Chassis shared storage (SEEPROM) is not operational.
Recommended Action
If you see this fault, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inoperable
mibFaultName: fltEquipmentChassisSeepromInoperable
moClass: equipment:Chassis
Affected MO: sys/chassis-[id]
fltExtmgmtIfMgmtifdown
Fault Code: F0736
Message
Management interface on Fabric Interconnect [id] is [operState]
Explanation
This fault occurs when a fabric interconnect reports that the operational state of an external management interface is down.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the state transitions of the external management interface on the fabric interconnect.
Step 2 Check the link connectivity for the external management interface.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltExtmgmtIfMgmtifdown
Affected MO: sys/switch-[id]/extmgmt-intf
fltPowerChassisMemberPowerGroupCapInsufficient
Fault Code: F0740
Message
Chassis [id] cannot be capped as group cap is low. Please consider raising the cap.
Explanation
This fault typically occurs when an updated group cap is insufficient to meet the minimum hardware requirements and a chassis that has just been added to the power group cannot be capped as a result.
Recommended Action
If you see this fault, take the following actions:
Step 1 Consider increasing the group cap.
Step 2 Reduce the number of blade servers or chassis in the Cisco FPR instance.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: group-cap-insufficient
mibFaultName: fltPowerChassisMemberPowerGroupCapInsufficient
moClass: power:ChassisMember
Affected MO: sys/power-ep/group-[name]/ch-member-[id]
fltPowerChassisMemberChassisFirmwareProblem
Fault Code: F0741
Message
Chassis [id] cannot be capped as at least one of the CMC or CIMC or BIOS firmware version is less than 1.4. Please upgrade the firmware for cap to be applied.
Explanation
This fault typically occurs when the CIMC firmware on a server is an earlier release than Cisco FPR, Release 1.4.
Recommended Action
If you see this fault, consider upgrading the CIMC firmware, and the entire Cisco FPR instance if necessary, to Cisco FPR, Release 1.4 or later.
Fault Details
Cause: old-chassis-component-firmware
mibFaultName: fltPowerChassisMemberChassisFirmwareProblem
moClass: power:ChassisMember
Affected MO: sys/power-ep/group-[name]/ch-member-[id]
fltPowerChassisMemberChassisPsuInsufficient
Fault Code: F0742
Message
Chassis [id] cannot be capped as at least two PSU need to be powered
Explanation
This fault typically occurs when at least two PSUs are not powered on.
Recommended Action
If you see this fault, insert at least two PSUs and power them on.
Fault Details
mibFaultName: fltPowerChassisMemberChassisPsuInsufficient
moClass: power:ChassisMember
Affected MO: sys/power-ep/group-[name]/ch-member-[id]
fltPowerChassisMemberChassisPsuRedundanceFailure
Fault Code: F0743
Message
Chassis [id] was configured for redundancy, but running in a non-redundant configuration.
Explanation
This fault typically occurs when chassis power redundancy has failed.
Recommended Action
If you see this fault, take the following actions:
Step 1 Consider adding more PSUs to the chassis.
Step 2 Replace any non-functional PSUs.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: psu-redundancy-fail
mibFaultName: fltPowerChassisMemberChassisPsuRedundanceFailure
moClass: power:ChassisMember
Affected MO: sys/power-ep/group-[name]/ch-member-[id]
fltPowerBudgetPowerCapReachedCommit
Fault Code: F0744
Message
P-State lowered as consumption hit power cap for server [chassisId]/[slotId]P-State lowered as consumption hit power cap for server [id]
Explanation
This fault typically occurs when Cisco FPR Manager is actively capping the power for a blade server.
Recommended Action
If you see this fault, no action is needed.
Fault Details
Cause: power-consumption-hit-limit
mibFaultName: fltPowerBudgetPowerCapReachedCommit
Affected MO: sys/chassis-[id]/blade-[slotId]/budget
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/budget
Affected MO: sys/chassis-[id]/budget
Affected MO: sys/rack-unit-[id]/budget
Affected MO: sys/rack-unit-[id]/ext-board-[id]/budget
fltSysdebugAutoCoreFileExportTargetAutoCoreTransferFailure
Fault Code: F0747
Message
Auto core transfer failure at remote server [hostname]:[path] [exportFailureReason]
Explanation
This fault occurs when Cisco Firepower Manager cannot transfer a core file to a remote TFTP server. This is typically the result of one of the following issues:
- The remote TFTP server is not accessible.
- One or more of the parameters for the TFTP server that are specified for the core export target, such as path, port, and server name, are incorrect.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify the connectivity to the remote server.
Step 2 Verify the path information of the remote server.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltSysdebugAutoCoreFileExportTargetAutoCoreTransferFailure
moClass: sysdebug:AutoCoreFileExportTarget
Affected MO: sys/sysdebug/file-export
fltFabricMonSpanConfigFail
Fault Code: F0757
Message
Configuration for traffic monitor [name] failed, reason: [configFailReason]
Explanation
This fault typically occurs when the configuration of a traffic monitoring session is incorrect.
Recommended Action
If you see this fault, correct the configuration problem provided in the fault description.
Fault Details
mibFaultName: fltFabricMonSpanConfigFail
Affected MO: fabric/lanmon/[id]/eth-mon-[name]
fltPowerBudgetChassisPsuInsufficient
Fault Code: F0764
Message
Chassis [id] cannot be capped as the available PSU power is not enough for the chassis and the blades. Please correct the problem by checking input power or replace the PSU
Explanation
This fault typically occurs when the available PSU power is not enough to deploy the power budget of chassis and blades.
Recommended Action
If you see this fault, check the PSU input power or replace the PSU.
Fault Details
mibFaultName: fltPowerBudgetChassisPsuInsufficient
Affected MO: sys/chassis-[id]/blade-[slotId]/budget
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/budget
Affected MO: sys/chassis-[id]/budget
Affected MO: sys/rack-unit-[id]/budget
Affected MO: sys/rack-unit-[id]/ext-board-[id]/budget
fltPowerBudgetTStateTransition
Fault Code: F0765
Message
Blade [chassisId]/[slotId] has been severely throttled. CIMC can recover if budget is redeployed to the blade or by rebooting the blade. If problem persists, please ensure that OS is ACPI compliantRack server [id] has been severely throttled. CIMC can recover if budget is redeployed to the blade or by rebooting the blade. If problem persists, please ensure that OS is ACPI compliant
Explanation
This fault typically occurs when the processor T-state is used to severely throttle the CPU.
Recommended Action
If you see this fault, take the following actions:
Step 1 Redeploy the power budget for the affected power group, blade server, or chassis.
Step 2 If the problem persists, reboot the blade server.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltPowerBudgetTStateTransition
Affected MO: sys/chassis-[id]/blade-[slotId]/budget
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/budget
Affected MO: sys/chassis-[id]/budget
Affected MO: sys/rack-unit-[id]/budget
Affected MO: sys/rack-unit-[id]/ext-board-[id]/budget
fltPowerPolicyPowerPolicyApplicationFail
Fault Code: F0766
Message
Insufficient budget to apply no-cap priority through policy [name]. Blades will continue to be capped
Explanation
This fault occurs when a power policy cannot be applied to one or more blade servers. The affected blade servers cannot operate normally without power capping due to the limited power budget for those servers.
Recommended Action
If you see this fault, take the following actions:
Step 1 Increase the power budget for the blade servers in the power policy.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltPowerPolicyPowerPolicyApplicationFail
Affected MO: org-[name]/power-policy-[name]
fltMgmtIfNew
Fault Code: F0772
Message
New connection discovered on Management Port [id] in server [id]
Explanation
This fault occurs when the connectivity between a server and a FEX is added or changed.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the connectivity between the server and FEX.
Step 2 If the connectivity was changed by mistake, restore it to its previous configuration.
Step 3 If the connectivity change was intentional, reacknowledge the server.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltMgmtIfNew
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/if-[id]
Affected MO: sys/fex-[id]/mgmt/if-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/if-[id]
Affected MO: sys/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/if-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/mgmt/if-[id]
Affected MO: sys/switch-[id]/mgmt/if-[id]
fltAdaptorExtEthIfMissing
Fault Code: F0775
Message
Connection to Adapter [id] eth interface [id] in server [id] missing
Explanation
The link for a network-facing adapter interface is misconnected. Cisco FPR Manager raises this fault when it detects that the connectivity between a previously configured port on a fabric interconnect or FEX and its prior peer network-facing adapter interface is misconnected or missing.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check whether the adapter interface is connected to a port belonging to its peer fabric interconnect or FEX.
Step 2 If the connectivity seems correct, reacknowledge the server.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltAdaptorExtEthIfMissing
moClass: adaptor:ExtEthIf
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]
fltStorageLocalDiskSlotEpUnusable
Fault Code: F0776
Message
Local disk [id] on server [serverId] is not usable by the operating system
Explanation
This fault occurs when the server disk drive is in a slot that is not supported by the storage controller.
Recommended Action
If you see this fault, take the following actions:
Step 1 Insert the server disk drive in a supported slot.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inoperable
mibFaultName: fltStorageLocalDiskSlotEpUnusable
moClass: storage:LocalDiskSlotEp
Affected MO: sys/chassis-[id]/blade-[slotId]/board/disk-[id]
Affected MO: sys/rack-unit-[id]/board/disk-[id]
fltFabricEthEstcPcEpDown
Fault Code: F0777
Message
[type] Member [slotId]/[aggrPortId]/[portId] of Port-Channel [portId] on fabric interconnect [id] is down, membership: [membership][type] Member [slotId]/[portId] of Port-Channel [portId] on fabric interconnect [id] is down, membership: [membership]
Explanation
This fault typically occurs when a member port in an Ethernet port channel is down.
Recommended Action
If you see this fault, take the following action:
Step 1 Check the link connectivity on the upstream Ethernet switch.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFabricEthEstcPcEpDown
moClass: fabric:EthEstcPcEp
Affected MO: fabric/eth-estc/[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
fltEquipmentFexIdentity-unestablishable
Fault Code: F0778
Message
Fex [id] has an invalid FRU
Explanation
This fault typically occurs because Cisco FPR Manager detected an unsupported chassis. For example, the model, vendor, or revision is not recognized.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the capability catalog in Cisco FPR Manager is up to date. If necessary, update the catalog.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: identity-unestablishable
mibFaultName: fltEquipmentFexIdentityUnestablishable
Affected MO: sys/fex-[id]
fltEquipmentFanModuleInoperable
Fault Code: F0794
Message
Fan module [tray]-[id] in chassis [id] operability: [operability]Fan module [tray]-[id] in server [id] operability: [operability]Fan module [tray]-[id] in fabric interconnect [id] operability: [operability]
Explanation
This fault occurs if a fan module is not operational.
Recommended Action
If you see this fault, take the following actions:
Step 1 Remove and reinstall the fan module. If multiple fans are affected by this fault, remove and reinstall one fan module at a time.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inoperable
mibFaultName: fltEquipmentFanModuleInoperable
moClass: equipment:FanModule
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]
fltLsmaintMaintPolicyUnresolvableScheduler
Fault Code: F0795
Message
Schedule [schedName] referenced by maintenance policy [name] does not exist
Explanation
The schedule that is referenced by the maintenance policy does not exist. This fault typically occurs as a result of one of the following issues:
- The schedule does not exist.
- The schedule was deleted.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check if the named schedule exists. If it is deleted or missing, try to create it.
Step 2 If the named schedule is deleted or missing, recreate it.
Step 3 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: non-existent-scheduler
mibFaultName: fltLsmaintMaintPolicyUnresolvableScheduler
moClass: lsmaint:MaintPolicy
Affected MO: org-[name]/maint-[name]
fltProcessorUnitIdentity-unestablishable
Fault Code: F0801
Message
Processor [id] on server [chassisId]/[slotId] has an invalid FRUProcessor [id] on server [id] has an invalid FRU
Explanation
This fault typically occurs because Cisco FPR Manager has detected an unsupported CPU in the server. For example, the model, vendor, or revision is not recognized.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the capability catalog in Cisco FPR Manager is up to date. If necessary, update the catalog.
Step 2 If the above action did not resolve the issue, you may have an unsupported CPU configuration in the server. Create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: identity-unestablishable
mibFaultName: fltProcessorUnitIdentityUnestablishable
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]
Affected MO: sys/rack-unit-[id]/board/cpu-[id]
fltIqnpoolPoolEmpty
Fault Code: F0821
Message
iqn pool [name] is empty
Explanation
This fault typically occurs when an IQN pool does not contain any IQNs.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the pool is in use, add a block of IQNs to the pool.
Step 2 If the pool is not in use, ignore the fault.
Fault Details
mibFaultName: fltIqnpoolPoolEmpty
Affected MO: org-[name]/iqn-pool-[name]
fltFabricDceSwSrvPcEpDown
Fault Code: F0831
Message
[type] Member [slotId]/[aggrPortId]/[portId] of Port-Channel [portId] on fabric interconnect [id] is down, membership: [membership][type] Member [slotId]/[portId] of Port-Channel [portId] on fabric interconnect [id] is down, membership: [membership]
Explanation
This fault typically occurs when a member port in a fabric port channel is down.
Recommended Action
If you see this fault, take the following action:
Step 1 Check the link connectivity between the FEX or IOM and the fabric interconnect.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFabricDceSwSrvPcEpDown
moClass: fabric:DceSwSrvPcEp
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
fltFabricEpMgrEpTransModeFail
Fault Code: F0832
Message
Port constraint violation on switch [id]: [confQual]
Explanation
This fault occurs when at least one logical interface is misconfigured. This can happen when upgrading to a different type or series of fabric interconnect or when importing a configuration.The configuration must meet the following constraints:
- There must be at most one logical port per fabric interconnect ID/module ID/port ID.
Recommended Action
If you see this fault, take the following action:
Step 1 Create a list of all logical interfaces that are misconfigured and have caused an ’error-misconfigured’ fault.
Step 2 For each logical interface, note the reason listed in the fault for the misconfiguration.
Step 3 Log into Cisco FPR Manager and correct each misconfigured logical interface. If you used the Cisco FPR Manager CLI, commit all changes.
Step 4 Review any faults or error messages that describe additional misconfigurations and correct those errors.
Step 5 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFabricEpMgrEpTransModeFail
fltFabricPIoEpErrorMisconfigured
Fault Code: F0834
Message
Interface [name] is [operState]. Reason: [operStateReason]
Explanation
This fault occurs when a logical interface is misconfigured. This can happen when upgrading to a different type or series of fabric interconnect or when importing a configuration.
Recommended Action
If you see this fault, take the following action:
Step 1 Create a list of all logical interfaces that are misconfigured and have caused an ’error-misconfigured’ fault.
Step 2 For each logical interface, note the reason listed in the fault for the misconfiguration.
Step 3 Log into Cisco FPR Manager and correct each misconfigured logical interface. If you used the Cisco FPR Manager CLI, commit all changes.
Step 4 Review any faults or error messages that describe additional misconfigurations and correct those errors.
Step 5 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: interface-misconfigured
mibFaultName: fltFabricPIoEpErrorMisconfigured
Affected MO: fabric/eth-estc/[id]/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/eth-target-ep-[name]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/net-group-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/net-group-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/net-group-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/lan/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/net-group-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/net-group-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/net-group-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/net-[name]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/san/net-[name]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/san/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/san/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/san/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/server/chassis-[chassisId]
Affected MO: fabric/server/chassis-[chassisId]/slot-[slotId]
Affected MO: fabric/server/chassis-ep-ven-[vendor]-mod[model]-ser-[serial]
Affected MO: fabric/server/compute-ep-ven-[vendor]-mod-[model]-ser-[serial]
Affected MO: fabric/server/sw-[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-port-[portId]
Affected MO: sys/switch-[id]/access-eth/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/eth-target-[name]
Affected MO: sys/switch-[id]/border-eth/ethestc-ep-slot-[slotId]port-[portId]/eth-target-[name]
Affected MO: sys/switch-[id]/border-eth/pc-[portId]/eth-target-[name]
Affected MO: sys/switch-[id]/border-eth/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/eth-target-[name]
Affected MO: sys/switch-[id]/border-fc/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/eth-target-[name]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/pc-[portId]/eth-target-[name]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/eth-target-[name]
Affected MO: sys/switch-[id]/phys/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/eth-target-[name]
Affected MO: sys/switch-[id]/ssp-lanmon-eth/ssp-mon-session[name]/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/eth-target-[name]
Affected MO: sys/tbh/border-eth/ethestc-ep-slot-[slotId]port-[portId]/eth-target-[name]
Affected MO: sys/tbh/border-eth/pc-[portId]/eth-target-[name]
Affected MO: sys/tbh/border-eth/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/eth-target-[name]
fltFabricEthLanEpMissingPrimaryVlan
Fault Code: F0835
Message
Primary vlan missing from fabric: [switchId], port: [slotId]/[aggrPortId]/[portId].Primary vlan missing from fabric: [switchId], port: [slotId]/[portId].
Explanation
This fault occurs when an uplink port or port channel is configured with a primary VLAN that does not exist in the Cisco FPR instance.
Recommended Action
If you see this fault, take the following action:
Step 1 Update the configuration of the port or port channel to include a primary VLAN.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: missing-primary-vlan
mibFaultName: fltFabricEthLanEpMissingPrimaryVlan
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
fltFabricEthLanPcMissingPrimaryVlan
Fault Code: F0836
Message
Primary vlan missing from fabric: [switchId], port-channel: [portId].
Explanation
This fault occurs when an uplink port or port channel is configured with a primary VLAN that does not exist in the Cisco FPR instance.
Recommended Action
If you see this fault, take the following action:
Step 1 Update the configuration of the port or port channel to include a primary VLAN.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: missing-primary-vlan
mibFaultName: fltFabricEthLanPcMissingPrimaryVlan
Affected MO: fabric/lan/[id]/pc-[portId]
fltVnicEtherPinningMismatch
Fault Code: F0840
Message
Hard pinning target for eth vNIC [name], service profile [name] does not have all the required vlans configured
Explanation
This fault occurs when one or more VLANs required by vNIC in a service profile are not configured on the target uplink port or port channel for a hard-pinned LAN pin group.
Recommended Action
If you see this fault, take the following actions:
Step 1 In the LAN Uplinks Manager of the Cisco FPR Manager GUI, configure all of the VLANs in the vNIC in the target uplink port or port channel for the LAN pin group. If you prefer to use the Cisco FPR Manager CLI, navigate to scope /eth-uplink/vlan and create the required member ports for the LAN pin group.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltVnicEtherPinningMismatch
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]
fltVnicEtherPinningMisconfig
Fault Code: F0841
Message
Hard pinning target for eth vNIC [name], service profile [name] is missing or misconfigured
Explanation
This fault occurs when one or more vNIC target uplink ports or port channels for a hard-pinned LAN pin group are either missing or misconfigured as the wrong port type.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the LAN pin group configuration.
Step 2 Correct the configuration of the port and port channels in the pin group.
Step 3 Ensure that all required vLANs are allowed on the target ports or port channels.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltVnicEtherPinningMisconfig
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]
fltProcessorUnitDisabled
Fault Code: F0842
Message
Processor [id] on server [chassisId]/[slotId] operState: [operState]Processor [id] on server [id] operState: [operState]
Explanation
This fault occurs in the unlikely event that a processor is disabled.
Recommended Action
If you see this fault, take the following actions:
Step 1 If this fault occurs on a blade server, remove and reinsert the server into the chassis.
Step 2 In Cisco FPR Manager, decommission and recommission the blade server.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-disabled
mibFaultName: fltProcessorUnitDisabled
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]
Affected MO: sys/rack-unit-[id]/board/cpu-[id]
fltMemoryUnitDisabled
Fault Code: F0844
Message
DIMM [location] on server [chassisId]/[slotId] operState: [operState]DIMM [location] on server [id] operaState: [operState]
Explanation
This fault is raised when the server BIOS disables a DIMM. The BIOS could disable a DIMM for several reasons, including incorrect location of the DIMM or incompatible speed.
Recommended Action
If you see this fault, refer to the Cisco FPR B-Series Troubleshooting Guide for information on how to resolve the DIMM issues.
Fault Details
Cause: equipment-disabled
mibFaultName: fltMemoryUnitDisabled
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]/mem-[id]
Affected MO: sys/rack-unit-[id]/board/memarray-[id]/mem-[id]
fltFirmwareBootUnitActivateStatusFailed
Fault Code: F0856
Message
Activation failed and Activate Status set to failed.
Explanation
This fault typically occurs for the following reasons: when firmware activation fails, or if the after activation running image is not the corresponding startup image.
- Firmware activation failed.
- The version of firmware running on the server after activation is not the version listed in Cisco FPR Manager as the startup image.
Recommended Action
If you see this fault, take the following actions:
Step 1 Go to FSM tab for the endpoint on which the fault is raised and review the error description for the reason that the activation failed.
Step 2 If the FSM failed, review the error message in the FSM.
Step 3 If possible, correct the problem described in the error message.
Step 4 If the problem persists, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFirmwareBootUnitActivateStatusFailed
moClass: firmware:BootUnit
Affected MO: capabilities/ep/mgmt-ext/fw-boot-def/bootunit-[type]
Affected MO: capabilities/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/graphics-card-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/os-ctrl/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/epmfpga-[slot]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/fpga/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/rommon/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/fex-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/os-ctrl/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/graphics-card-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/os-ctrl/fw-boot-def/bootunit-[type]
Affected MO: sys/switch-[id]/mgmt/fw-boot-def/bootunit-[type]
fltFabricInternalPcDown
Fault Code: F0858
Message
[type] port-channel [portId] on fabric interconnect [id] oper state: [operState], reason: [stateQual]
Explanation
This fault occurs when the transport VIF for a server is down. Cisco FPR Manager raises this fault when a fabric interconnect reports the connectivity state on virtual interface as one of the following:
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the blade server discovery was successful.
Step 2 Check the states on all communicating ports from end to end.
Step 3 If connectivity seems correct, decommission and recommission the server.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: operational-state-down
mibFaultName: fltFabricInternalPcDown
moClass: fabric:InternalPc
Affected MO: fabric/server/sw-[id]/pc-[portId]
fltMgmtEntityDevice-1-shared-storage-error
Fault Code: F0863
Message
device [chassis1], error accessing shared-storage
Explanation
This fault occurs in an unlikely event that the shared storage selected for writing the cluster state is not accessible. This fault is typically a transient fault. You might see this fault when one of the following occurs: (a) the Fabric Interconnect boots, (b) the IO Module is reset, (c) the rack server is reboot, or (d) system is upgraded/downgraded. If this fault is not cleared after the system returns to normal operation following the reboot/reset/upgrade/downgrade, then it may affect the full HA functionality of the Fabric Interconnect cluster.
Recommended Action
If this fault is not cleared even after the system returns to normal operation, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: device-shared-storage-error
mibFaultName: fltMgmtEntityDevice1SharedStorageError
Affected MO: sys/mgmt-entity-[id]
fltMgmtEntityDevice-2-shared-storage error
Fault Code: F0864
Message
device [chassis2], error accessing shared-storage
Explanation
This fault occurs in an unlikely event that the shared storage selected for writing the cluster state is not accessible. This fault is typically a transient fault. You might see this fault when one of the following occurs: (a) the Fabric Interconnect boots, (b) the IO Module is reset, (c) the rack server is reboot, or (d) system is upgraded/downgraded. If this fault is not cleared after the system returns to normal operation following the reboot/reset/upgrade/downgrade, then it may affect the full HA functionality of the Fabric Interconnect cluster.
Recommended Action
If this fault is not cleared even after the system returns to normal operation, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: device-shared-storage-error
mibFaultName: fltMgmtEntityDevice2SharedStorageError
Affected MO: sys/mgmt-entity-[id]
fltMgmtEntityDevice-3-shared-storage error
Fault Code: F0865
Message
device [chassis3], error accessing shared-storage
Explanation
This fault occurs in an unlikely event that the shared storage selected for writing the cluster state is not accessible. This fault is typically a transient fault. You might see this fault when one of the following occurs: (a) the Fabric Interconnect boots, (b) the IO Module is reset, (c) the rack server is reboot, or (d) system is upgraded/downgraded. If this fault is not cleared after the system returns to normal operation following the reboot/reset/upgrade/downgrade, then it may affect the full HA functionality of the Fabric Interconnect cluster.
Recommended Action
If this fault is not cleared even after the system returns to normal operation, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: device-shared-storage-error
mibFaultName: fltMgmtEntityDevice3SharedStorageError
Affected MO: sys/mgmt-entity-[id]
fltMgmtEntityHa-ssh-keys-mismatched
Fault Code: F0866
Message
Fabric Interconnect [id], management services, mismatched SSH keys
Explanation
This fault indicates that one of the following scenarios has occurred:
- The internal SSH keys used for HA in the cluster configuration are mismatched. This causes certain operations to fail.
- Another fabric interconnect is connected to the primary fabric interconnect in the cluster without first erasing the existing configuration in the primary.
Recommended Action
If you see this fault, take the following actions:
Step 1 Log into the Cisco FPR Manager CLI on the subordinate fabric interconnect.
Step 2 Enter connect local-mgmt
Step 3 Enter erase configuration to erase the configuration on the subordinate fabric interconnect and reboot it.
Step 4 When the secondary fabric interconnect has rebooted, reconfigure it for the cluster.
Step 5 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: ha-ssh-keys-mismatched
mibFaultName: fltMgmtEntityHaSshKeysMismatched
Affected MO: sys/mgmt-entity-[id]
fltComputeBoardPowerFail
Fault Code: F0868
Message
Motherboard of server [chassisId]/[slotId] (service profile: [assignedToDn]) power: [power]Motherboard of server [id] (service profile: [assignedToDn]) power: [power]
Explanation
This fault typically occurs when the power sensors on a blade server detect a problem.
Recommended Action
If you see this fault, take the following actions:
Step 1 Remove the blade server from the chassis.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltComputeBoardPowerFail
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/rack-unit-[id]/board
fltVmVifLinkState
Fault Code: F0876
Message
Virtual interface [vifId] link is down; reason [stateQual]
Explanation
This fault occurs when Cisco FPR cannot send or receive data through an uplink port.
Recommended Action
If you see this fault, take the following actions:
Step 1 Enable the failed uplink port.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltVmVifLinkState
Affected MO: vmm/computeEp-[uuid]/nic-[name]/sw-[phSwitchId]vif-[vifId]
Affected MO: vmm/hv-[uuid]/nic-[name]/sw-[phSwitchId]vif-[vifId]
Affected MO: vmm/vm-[uuid]/nic-[name]/sw-[phSwitchId]vif-[vifId]
fltEquipmentPsuPowerSupplyShutdown
Fault Code: F0881
Message
Power supply [id] in chassis [id] shutdown reason:[powerStateQualifier]
Explanation
This fault typically occurs when a power supply unit in a chassis, fabric interconnect, or a FEX is shut down, either due to higher than expected power current, higher than expected temperatures, or the failure of a fan.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the server.
Step 2 Review the Cisco FPR Site Preparation Guide to ensure the servers have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco FPR chassis or rack server are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Verify that the power cord is properly connected to the PSU and the power source.
Step 7 Verify that the power source is 220 volts.
Step 8 Verify that the PSU is properly installed in the chassis or fabric interconnect.
Step 9 Remove the PSU and reinstall it.
Step 10 Replace the PSU.
Step 11 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentPsuPowerSupplyShutdown
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentPsuPowerThreshold
Fault Code: F0882
Message
Power supply [id] on chassis [id] has exceeded its power thresholdPower supply [id] on server [id] has exceeded its power threshold
Explanation
This fault occurs when a power supply unit is drawing too much current.
Recommended Action
If you see this fault, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentPsuPowerThreshold
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentPsuInputError
Fault Code: F0883
Message
Power supply [id] on chassis [id] has disconnected cable or bad input voltagePower supply [id] on server [id] has disconnected cable or bad input voltage
Explanation
This fault occurs when a power cable is disconnected or input voltage is incorrect.
Recommended Action
If you see this fault, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentPsuInputError
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltNetworkElementInventoryFailed
Fault Code: F0885
Message
Fabric Interconnect [id] inventory is not complete [inventoryStatus]
Explanation
Cisco FPR Manager raises this fault when the management subsystem is unable to perform an inventory of the physical components, such as I/O cards or physical ports.
Recommended Action
If you see this fault, take the following actions:
Step 1 Ensure that both fabric interconnects in an HA cluster are running the same software versions.
Step 2 Ensure that the fabric interconnect software is a version that is compatible with the Cisco FPR Manager software.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltNetworkElementInventoryFailed
Affected MO: sys/switch-[id]
fltAdaptorUnitExtnUnidentifiable-fru
Fault Code: F0900
Message
Adapter extension [id] in server [chassisId]/[slotId] has unidentified FRU
Explanation
This fault typically occurs because Cisco FPR Manager has detected an unsupported adapter unit extension, such as a pass-through adaptor. For example, the model, vendor, or revision is not recognized.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that a supported adapter unit extension is installed.
Step 2 Verify that the capability catalog in Cisco FPR Manager is up to date. If necessary, update the catalog.
Step 3 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: unidentifiable-fru
mibFaultName: fltAdaptorUnitExtnUnidentifiableFru
moClass: adaptor:UnitExtn
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/adaptor-extn-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/adaptor-extn-[id]
fltAdaptorUnitExtnMissing
Fault Code: F0901
Message
Adapter extension [id] in server [chassisId]/[slotId] presence: [presence]
Explanation
This fault typically occurs when an I/O adapter unit extension, such as a pass-through adapter, is missing. Cisco FPR Manager raises this fault when any of the following scenario occur:
- The endpoint reports there is no adapter unit extension, such as a pass-through adapter, plugged into the adapter slot.
- The endpoint cannot detect or communicate with the adapter unit extension plugged into the adapter slot.
Recommended Action
If you see this fault, take the following actions:
Step 1 Ensure the adapter unit extension is properly plugged into an adapter slot in the server.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltAdaptorUnitExtnMissing
moClass: adaptor:UnitExtn
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/adaptor-extn-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/adaptor-extn-[id]
fltEquipmentFexFex-unsupported
Fault Code: F0902
Message
Fex [id] with model [model] is unsupported
Explanation
This fault typically occurs because Cisco FPR Manager has detected an unsupported FEX. For example, the model, vendor, or revision is not recognized.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that a supported FEX is installed.
Step 2 Verify that the capability catalog in Cisco FPR Manager is up to date. If necessary, update the catalog.
Step 3 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentFexFexUnsupported
Affected MO: sys/fex-[id]
fltVnicIScsiConfig-failed
Fault Code: F0903
Message
iSCSI vNIC [name], service profile [name] has duplicate iqn name [initiatorName]
Explanation
This fault typically occurs when IScsi Vnics refer the same iqn name.
Recommended Action
If you see this fault, take the following actions:
Step 1 Make sure that iqn name unique per iSCSI vnic.
Step 2 Using show identity iqn check if the iSCSI vnic is registered in the universe.
Step 3 Try non disruptive actions such as changing description on the Service Profile to register the iqn in the universe.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: configuration-failed
mibFaultName: fltVnicIScsiConfigFailed
Affected MO: org-[name]/ls-[name]/iscsi-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/iscsi-[name]
fltPkiKeyRingStatus
Fault Code: F0909
Message
[name] Keyring’s certificate is invalid, reason: [certStatus].
Explanation
This fault occurs when certificate status of Keyring has become invalid.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: invalid-keyring-certificate
mibFaultName: fltPkiKeyRingStatus
Affected MO: sys/pki-ext/keyring-[name]
fltPkiTPStatus
Fault Code: F0910
Message
[name] Trustpoint’s cert-chain is invalid, reason: [certStatus].
Explanation
This fault occurs when certificate status of TrustPoint has become invalid.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: invalid-trustpoint-cert-chain
mibFaultName: fltPkiTPStatus
Affected MO: sys/pki-ext/tp-[name]
fltComputePhysicalDisassociationFailed
Fault Code: F0915
Message
Failed to disassociate server [id]Failed to disassociate server [chassisId]/[slotId]
Explanation
This fault typically occurs for one of the following reasons:
- The server is down.
- The data path is not working.
- Cisco FPR Manager cannot communicate with one or more of the fabric interconnect, the server, or a component on the server.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the communication path to the server including fabric interconnect server ports, IOM link and the current state of the server
Step 2 If the server is stuck in an inappropriate state, such as booting, power cycle the server.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: disassociation-failed
mibFaultName: fltComputePhysicalDisassociationFailed
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalNetworkMisconfigured
Fault Code: F0916
Message
Server [id] (service profile: [assignedToDn]) has mis-configured network vif resourcesServer [chassisId]/[slotId] (service profile: [assignedToDn]) has mis-configured network vif resources
Explanation
This fault would occur when FPRM VIF-id Map is not the same as the VIF-id map deployed on the adaptor upon Full Backup-Restore etc.
Recommended Action
If you see this fault, take the following actions:
Step 1 Re-acknowledge the server. This will trigger Deep Discovery-Deep Association & will resolve the issue
Step 2 If the above actions did not resolve the issue, execute the show tech-support command and contact Cisco Technical Support.
Fault Details
mibFaultName: fltComputePhysicalNetworkMisconfigured
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/rack-unit-[id]
fltVnicProfileProfileConfigIncorrect
Fault Code: F0917
Message
The Port Profile [name] has an invalid configuration.
Explanation
This fault occurs there is an invalid entry for a port profile configuration.
Recommended Action
Check documentation and correct the offending entry in the port profile configuration.
Fault Details
Cause: profile-config-incorrect
mibFaultName: fltVnicProfileProfileConfigIncorrect
Affected MO: fabric/lan/profiles/vnic-[name]
fltVnicEtherIfVlanAccessFault
Fault Code: F0932
Message
The named vlan [name] for vNIC [name] cannot be accessed from org [name]
Explanation
This fault typically occurs when a Service Profile’s vnic interface (LAN) is resolvable but the service profile does not have access to the vlan. In this case, the default vlan will be used.
Recommended Action
This fault will be removed if you perform one of the following actions:
Step 1 Change the vnic’s interface name to a VLAN that you have access to.
Step 2 If you wish to use the default vlan, change the vnic’s interface name to default.
Step 3 Configure access to the named vlan by creating a vlan permit or vlan group permit in the service profile’s org (or a parent org).
Fault Details
Cause: inaccessible-vlan-referenced
mibFaultName: fltVnicEtherIfVlanAccessFault
Affected MO: fabric/lan/network-sets/fabric-network-[name]/fabric-network-def-[name]/vm-network-def-[name]/if-[name]
Affected MO: fabric/lan/profiles/vnic-[name]/if-[name]
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/lan-conn-templ-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/ipc-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ipc-[name]/if-[name]
fltVnicEtherIfVlanUnresolvable
Fault Code: F0933
Message
The named vlan [name] for vNIC [name] cannot be resolved
Explanation
This fault (warning) occurs when a Service Profile’s vnic interface (LAN) is unresolvable. In this case, the default vlan will be used as the operational vlan.
Recommended Action
This fault will be removed if you perform one of the following actions:
Step 1 Change the vnic interface name to an existing VLAN.
Step 2 Create the named vlan.
Fault Details
Cause: referenced-vlan-unresolvable
mibFaultName: fltVnicEtherIfVlanUnresolvable
Affected MO: fabric/lan/network-sets/fabric-network-[name]/fabric-network-def-[name]/vm-network-def-[name]/if-[name]
Affected MO: fabric/lan/profiles/vnic-[name]/if-[name]
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/lan-conn-templ-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/ipc-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ipc-[name]/if-[name]
fltVnicEtherIfInvalidVlan
Fault Code: F0934
Message
Invalid Vlan in the allowed vlan list
Explanation
This fault typically occurs when a vnic of a service profile or a port profile contains an invalid vlan. an invalid vlan can be any one of the following:
Step 1 an isolated vlan or a community vlan that is not associated to a valid primary vlan
Step 2 a primary vlan without any of its assoicated secondary vlans allowed on the vnic
Step 3 a vlan which has sharing-type or primary vlan name not matching to that of vlan in lan-side/appliance-side
Recommended Action
This fault will be removed if you perform one of the following actions:
Step 1 if invalid vlan is an isolated or community vlan then make sure it is mapped to a valid primary vlan.
Step 2 if invalid vlan is a primary vlan then either allow any of its secondary vlans or delete it from vnic or port profile.
Step 3 if invalid vlan is a vlan that does not match the sharing properties with the vlan of same vlan id in the lan-side/appliance-side, change the properties of this vlan to be the same as the other.
Fault Details
Cause: invalid-vlan-in-the-allowed-vlan-list
mibFaultName: fltVnicEtherIfInvalidVlan
Affected MO: fabric/lan/network-sets/fabric-network-[name]/fabric-network-def-[name]/vm-network-def-[name]/if-[name]
Affected MO: fabric/lan/profiles/vnic-[name]/if-[name]
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/lan-conn-templ-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/ipc-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ipc-[name]/if-[name]
fltFabricVlanVlanConflictPermit
Fault Code: F0935
Message
There are multiple vlans with id [id] have different accessability configured.
Explanation
This fault occurs when multipl global vlans with the same id have different access configurations.
Recommended Action
Change the access configuration by configuring VLAN/VLAN Group Permits.
Fault Details
Cause: vlan-conflict-permit
mibFaultName: fltFabricVlanVlanConflictPermit
Affected MO: fabric/eth-estc/[id]/net-[name]
Affected MO: fabric/eth-estc/net-[name]
Affected MO: fabric/lan/[id]/net-[name]
Affected MO: fabric/lan/net-[name]
fltFabricVlanReqVlanPermitUnresolved
Fault Code: F0936
Message
The VLAN permit does not reference any existing vlans.
Explanation
This fault occurs when a VLAN permit exists but there are no vnics by the name.
Recommended Action
Delete the VLAN permit, create the referenced VLAN (or ignore).
Fault Details
Cause: vlan-permit-unresolved
mibFaultName: fltFabricVlanReqVlanPermitUnresolved
Affected MO: org-[name]/vlan-req-[name]
fltFabricVlanGroupReqVlanGroupPermitUnresolved
Fault Code: F0937
Message
The VLAN permit does not reference any existing net groups.
Explanation
This fault occurs when a VLAN group permit exists but there are no referenced network groups.
Recommended Action
Delete the VLAN permit, create the referenced VLAN (or ignore).
Fault Details
Cause: group-permit-unresolved
mibFaultName: fltFabricVlanGroupReqVlanGroupPermitUnresolved
moClass: fabric:VlanGroupReq
Affected MO: org-[name]/vlan-group-req-[name]
fltExtpolClientClientLostConnectivity
Fault Code: F0988
Message
FPRM has lost connectivity with Firepower Central
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: client-lost-connectivity
mibFaultName: fltExtpolClientClientLostConnectivity
Affected MO: extpol/reg/clients/client-[id]
fltStorageLocalDiskDegraded
Fault Code: F0996
Message
Local disk [id] on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]Local disk [id] on server [id] operability: [operability]. Reason: [operQualifierReason]
Explanation
This fault occurs when the local disk has become degraded. The fault description will contain the physical drive state, which indicates the reason for the degradation.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the drive state is "rebuild" or "copyback", wait for the rebuild or copyback operation to complete.
Step 2 If the drive state is "predictive-failure", replace the disk.
Fault Details
Cause: equipment-degraded
mibFaultName: fltStorageLocalDiskDegraded
moClass: storage:LocalDisk
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]
fltStorageRaidBatteryDegraded
Fault Code: F0997
Message
RAID Battery on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]RAID Battery on server [id] operability: [operability]. Reason: [operQualifierReason]
Explanation
This fault occurs when the RAID backup unit is degraded.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the fault reason indicates the backup unit is in a relearning cycle, wait for relearning to complete.
Step 2 If the fault reason indicates the backup unit is about to fail, replace the backup unit.
Step 3 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-degraded
mibFaultName: fltStorageRaidBatteryDegraded
moClass: storage:RaidBattery
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/raid-battery
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/raid-battery
fltStorageRaidBatteryRelearnAborted
Fault Code: F0998
Message
RAID Battery on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]RAID Battery on server [id] operability: [operability]. Reason: [operQualifierReason]
Explanation
NOTE: This fault is not currently implemented by Firepower ManagerThis fault is present only as a placeholder, possibly for another release,such as stand-alone rack servers.---This fault occurs when the backup unit’s relearning cycle was aborted.
Recommended Action
If you see this fault, take the following actions:
Step 1 Retry the learn cycle.
Step 2 Replace the backup unit.
Fault Details
Cause: equipment-degraded
mibFaultName: fltStorageRaidBatteryRelearnAborted
moClass: storage:RaidBattery
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/raid-battery
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/raid-battery
fltStorageRaidBatteryRelearnFailed
Fault Code: F0999
Message
RAID Battery on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]RAID Battery on server [id] operability: [operability]. Reason: [operQualifierReason]
Explanation
NOTE: This fault is not currently implemented by Firepower ManagerThis fault is present only as a placeholder, possibly for another release,such as stand-alone rack servers.---This fault occurs when the backup unit’s relearning cycle has failed.
Recommended Action
If you see this fault, take the following actions:
Step 1 Retry the learn cycle.
Step 2 Replace the backup unit.
Fault Details
Cause: equipment-degraded
mibFaultName: fltStorageRaidBatteryRelearnFailed
moClass: storage:RaidBattery
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/raid-battery
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/raid-battery
fltStorageInitiatorConfiguration-error
Fault Code: F1001
Message
Initiator [name] either cannot be resolved or does not match with one of the storage targets. No zones are deployed for this initiator and the target.
Explanation
Initiator either cannot be resolved or does not match with one of the targets.
Recommended Action
If you see this fault, take the following action:
Step 1 Check if vhba interface referenced by this Initiator exsits.
Step 2 Check if switch id or vsan name of the vhba interface referenced by this Initiator matches one of the targets.
Fault Details
Cause: configuration-error
mibFaultName: fltStorageInitiatorConfigurationError
moClass: storage:Initiator
Affected MO: org-[name]/ls-[name]/grp-[name]/ini-[name]
Affected MO: org-[name]/san-conn-pol-[name]/grp-[name]/ini-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/grp-[name]/ini-[name]
fltStorageControllerPatrolReadFailed
Fault Code: F1003
Message
Controller [id] on server [chassisId]/[slotId] had a patrol read failure. Reason: [operQualifierReason]Controller [id] on server [id] had a patrol read failure. Reason: [operQualifierReason]
Explanation
NOTE: This fault is not currently implemented by Firepower ManagerThis fault is present only as a placeholder, possibly for another release,such as stand-alone rack servers.---This fault occurs when a Patrol Read operation has failed.
Recommended Action
Re-run the patrol read operation.
Fault Details
mibFaultName: fltStorageControllerPatrolReadFailed
moClass: storage:Controller
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]
fltStorageControllerInoperable
Fault Code: F1004
Message
Controller [id] on server [chassisId]/[slotId] is inoperable. Reason: [operQualifierReason]Controller [id] on server [id] is inoperable. Reason: [operQualifierReason]
Explanation
This fault occurs when the storage controller is inaccessible.
Recommended Action
For PCI and mezz-based storage controllers, check the seating of the storage controller. If the problem persists, replace the controller.
Fault Details
Cause: equipment-inoperable
mibFaultName: fltStorageControllerInoperable
moClass: storage:Controller
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]
fltStorageLocalDiskRebuildFailed
Fault Code: F1005
Message
Local disk [id] on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]Local disk [id] on server [id] operability: [operability]. Reason: [operQualifierReason]
Explanation
NOTE: This fault is not currently implemented by Firepower ManagerThis fault is present only as a placeholder, possibly for another release,such as stand-alone rack servers.---This fault occurs when a rebuild operation has failed. This may cause a degradation in performance.
Recommended Action
If you see this fault, take the following action:
Step 1 Retry the rebuild operation.
Step 2 Replace the disk.
Fault Details
mibFaultName: fltStorageLocalDiskRebuildFailed
moClass: storage:LocalDisk
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]
fltStorageLocalDiskCopybackFailed
Fault Code: F1006
Message
Local disk [id] on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]Local disk [id] on server [id] operability: [operability]. Reason: [operQualifierReason]
Explanation
NOTE: This fault is not currently implemented by Firepower ManagerThis fault is present only as a placeholder, possibly for another release,such as stand-alone rack servers.---This fault occurs when a copyback operation has failed. This may cause a degradation in performance.
Recommended Action
If you see this fault, take the following action:
Step 1 Retry the copyback operation.
Step 2 Replace the disk.
Fault Details
mibFaultName: fltStorageLocalDiskCopybackFailed
moClass: storage:LocalDisk
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]
fltStorageVirtualDriveInoperable
Fault Code: F1007
Message
Virtual drive [id] on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]Virtual drive [id] on server [id] operability: [operability]. Reason: [operQualifierReason]
Explanation
This fault occurs when the virtual drive has become inoperable.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify the presence and health of disks that are used by the virtual drive.
Step 2 If applicable, reseat or replace used disks.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inoperable
mibFaultName: fltStorageVirtualDriveInoperable
moClass: storage:VirtualDrive
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/vd-[id]
fltStorageVirtualDriveDegraded
Fault Code: F1008
Message
Virtual drive [id] on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]Virtual drive [id] on server [id] operability: [operability]. Reason: [operQualifierReason]
Explanation
This fault occurs when the virtual drive has become degraded. The fault description will contain the physical drive state, which indicates the reason for the degradation.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the drive is performing a consistency check operation, wait for the operation to complete.
Step 2 Verify the presence and health of disks that are used by the virtual drive.
Step 3 If applicable, reseat or replace used disks.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-degraded
mibFaultName: fltStorageVirtualDriveDegraded
moClass: storage:VirtualDrive
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/vd-[id]
fltStorageVirtualDriveReconstructionFailed
Fault Code: F1009
Message
Virtual drive [id] on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]Virtual drive [id] on server [id] operability: [operability]. Reason: [operQualifierReason]
Explanation
NOTE: This fault is not currently implemented by Firepower ManagerThis fault is present only as a placeholder, possibly for another release,such as stand-alone rack servers.---This fault occurs when a drive reconstruction operation has failed. This may cause a degradation in performance.
Recommended Action
If you see this fault, take the following action:
Step 1 Retry the reconstruction operation.
Step 2 Delete and recreate the virtual drive.
Fault Details
Cause: equipment-degraded
mibFaultName: fltStorageVirtualDriveReconstructionFailed
moClass: storage:VirtualDrive
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/vd-[id]
fltStorageVirtualDriveConsistencyCheckFailed
Fault Code: F1010
Message
Virtual drive [id] on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]Virtual drive [id] on server [id] operability: [operability]. Reason: [operQualifierReason]
Explanation
NOTE: This fault is not currently implemented by Firepower ManagerThis fault is present only as a placeholder, possibly for another release,such as stand-alone rack servers.---This fault occurs when a drive consistency check operation has failed. This may cause a degradation in performance.
Recommended Action
If you see this fault, take the following action:
Step 1 Retry the consistency check operation.
Step 2 Delete and recreate the virtual drive.
Fault Details
Cause: equipment-degraded
mibFaultName: fltStorageVirtualDriveConsistencyCheckFailed
moClass: storage:VirtualDrive
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/vd-[id]
fltAaaProviderGroupProvidergroup
Fault Code: F1026
Message
For [dn]: Server Group with name [name] already exist, You need to specify a unique name for this object.
Explanation
This fault typically occurs because Cisco FPR Manager has detected multiple provider-groups with same name.
Recommended Action
If you see this fault, take the following actions:
Step 1 Need to delete the duplicate provider group configured causing this problem.
Fault Details
Cause: provider-group-already-exists
mibFaultName: fltAaaProviderGroupProvidergroup
moClass: aaa:ProviderGroup
Affected MO: sys/ldap-ext/providergroup-[name]
Affected MO: sys/radius-ext/providergroup-[name]
Affected MO: sys/tacacs-ext/providergroup-[name]
fltAaaConfigServergroup
Fault Code: F1027
Message
For [dn]: [realm] Server Group with name [providerGroup] doesn’t exist or is not deployed.
Explanation
This fault typically occurs because Cisco FPR Manager has detected an unsupported authentication method.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that server group configured for authentication is present.
Step 2 If the server group is not configured, create the server group to use for authentication.
Fault Details
Cause: invalid-server-group
mibFaultName: fltAaaConfigServergroup
Affected MO: sys/auth-realm/console-auth
Affected MO: sys/auth-realm/default-auth
Affected MO: sys/auth-realm/domain-[name]/domain-auth
fltAaaRoleRoleNotDeployed
Fault Code: F1028
Message
Role [name] can’t be deployed. Error: [configStatusMessage]
Explanation
This fault typically occurs because Cisco FPR Manager has detected an unsupported role.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that total number of roles is less than maximum supported roles.
Step 2 Verify that sum of privileges across all roles is less than maximum privileges sum.
Fault Details
mibFaultName: fltAaaRoleRoleNotDeployed
Affected MO: sys/user-ext/role-[name]
fltAaaLocaleLocaleNotDeployed
Fault Code: F1029
Message
Locale [name] can’t be deployed. Error: [configStatusMessage]
Explanation
This fault typically occurs because Cisco FPR Manager has detected an unsupported locale.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that total number of locale is less than maximum supported roles.
Fault Details
Cause: locale-config-error
mibFaultName: fltAaaLocaleLocaleNotDeployed
Affected MO: sys/user-ext/locale-[name]
fltAaaUserRoleUserRoleNotDeployed
Fault Code: F1030
Message
For user: [name] role [name] can’t be assigned. Error: [configStatusMessage].For Ldap Group: [name] role [name] can’t be assigned. Error: [configStatusMessage].
Explanation
This fault typically occurs because Cisco FPR Manager has detected an unsupported user role for ldap groups or local users.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the role is present.
Step 2 Verify that the role is applied.
Step 3 Verify that the role is compatible with locales assigned to ldap group or local user.
Fault Details
Cause: user-role-config-error
mibFaultName: fltAaaUserRoleUserRoleNotDeployed
Affected MO: sys/ldap-ext/ldapgroup-[name]/role-[name]
Affected MO: sys/user-ext/remoteuser-[name]/role-[name]
Affected MO: sys/user-ext/user-[name]/role-[name]
fltAaaUserLocaleUserLocaleNotDeployed
Fault Code: F1031
Message
For user: [name] locale [name] can’t be assigned. Error: [configStatusMessage].For Ldap Group: [name] locale [name] can’t be assigned. Error: [configStatusMessage].
Explanation
This fault typically occurs because Cisco FPR Manager has detected an unsupported user locale for ldap groups or local users.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the locale is present.
Step 2 Verify that the locale is applied.
Step 3 Verify that the locale is compatible with roles assigned to ldap group or local user.
Fault Details
Cause: user-locale-config-error
mibFaultName: fltAaaUserLocaleUserLocaleNotDeployed
Affected MO: sys/ldap-ext/ldapgroup-[name]/locale-[name]
Affected MO: sys/user-ext/remoteuser-[name]/locale-[name]
Affected MO: sys/user-ext/user-[name]/locale-[name]
fltPkiKeyRingKeyRingNotDeployed
Fault Code: F1032
Message
Keyring [name] can’t be deployed. Error: [configStatusMessage]
Explanation
This fault typically occurs because Cisco FPR Manager has detected an invalid Keyring.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the trust point configured for this keyring is present.
Step 2 Verify that the trust point found above is applied.
Fault Details
Cause: keyring-config-error
mibFaultName: fltPkiKeyRingKeyRingNotDeployed
Affected MO: sys/pki-ext/keyring-[name]
fltCommSnmpSyscontactEmpty
Fault Code: F1033
Message
FPR Manager cannot deploy an empty value of SNMP Syscontact when Callhome is enabled. The previous value [sysContact] for SNMP Syscontact has been retained.
Explanation
This fault typically occurs when FPR Manager receives an invalid configuration from FPR Central wherein SNMP Syscontact is set to empty when Callhome is enabled.
Recommended Action
If you see this fault, please ensure that the SNMP Syscontact field on FPR Central is configured correctly for the domain group corresponding to this FPRM.
Fault Details
mibFaultName: fltCommSnmpSyscontactEmpty
Affected MO: sys/svc-ext/snmp-svc
fltCommDateTimeCommTimeZoneInvalid
Fault Code: F1034
Message
Timezone:[timezone] is invalid
Explanation
This fault typically occurs because Cisco FPR Manager has detected an unsupported role.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that total number of roles is less than maximum supported roles.
Step 2 Verify that sum of privileges across all roles is less than maximum privileges sum.
Fault Details
Cause: timezone-file-not-exists
mibFaultName: fltCommDateTimeCommTimeZoneInvalid
Affected MO: sys/svc-ext/datetime-svc
fltAaaUserLocalUserNotDeployed
Fault Code: F1035
Message
Local User [name] can’t be deployed. Error: [configStatusMessage]
Explanation
This fault typically occurs because Cisco FPR Manager has detected an invalid system user.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that local user name is not used by snmp users.
Fault Details
mibFaultName: fltAaaUserLocalUserNotDeployed
Affected MO: sys/user-ext/user-[name]
fltCommSnmpUserSnmpUserNotDeployed
Fault Code: F1036
Message
SNMP User [name] can’t be deployed. Error: [configStatusMessage]
Explanation
This fault typically occurs because Cisco FPR Manager has detected an invalid snmp user.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that snmp user name is not used by system users.
Fault Details
Cause: snmp-user-config-error
mibFaultName: fltCommSnmpUserSnmpUserNotDeployed
Affected MO: sys/svc-ext/snmp-svc/snmpv3-user-[name]
fltCommSvcEpCommSvcNotDeployed
Fault Code: F1037
Message
Communication Service configuration can’t be deployed. Error: [configStatusMessage]
Explanation
This fault typically occurs because Cisco FPR Manager has detected an invalid communication policy confiuration.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that ports configured across all communication services is unique.
Fault Details
Cause: comm-svc-config-error
mibFaultName: fltCommSvcEpCommSvcNotDeployed
fltSwVlanPortNsVLANCompNotSupport
Fault Code: F1056
Message
VLAN Port Count Optimization is not supported
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: no-vlan-optimization
mibFaultName: fltSwVlanPortNsVLANCompNotSupport
Affected MO: sys/switch-[id]/vlan-port-ns
fltPolicyControlEpSuspendModeActive
Fault Code: F1057
Message
FPRM is suspended from receiving updates from FPR Central.
Explanation
This fault occurs when FPRM enters into suspend state from receiving updates from FPR Central that it is registered with.
Recommended Action
If you see this fault, take the following actions:
Step 1 Please check if FPR Central is restored to a previous version or a policy roll-back has occured. You may have brought FPR in to manual suspension mode by using set suspendstate on command under the system-control-ep policy scope.
Step 2 Please confirm the suspend state by using show control-ep policy detail under system scope. If you still want to receive the updates from FPR Central, you need to restore it back to a version compatible with FPRM or set the suspend state to off by acknowledging it by using set ackstate acked under policy-control scope.
Step 3 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: suspend-mode-entered
mibFaultName: fltPolicyControlEpSuspendModeActive
moClass: policy:ControlEp
Affected MO: sys/control-ep-[type]
fltNetworkElementThermalThresholdCritical
Fault Code: F1080
Message
Fabric Interconnect [id] temperature: [thermal]
Explanation
This fault occurs when the temperature of a Fabric Interconnect exceeds a critical threshold value. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment.
- Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the Fabric Interconnect.
Step 2 Review the Cisco FPR Site Preparation Guide to ensure the Fabric Interconnects have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 6 Replace faulty Fabric Interconnects.
Step 7 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltNetworkElementThermalThresholdCritical
Affected MO: sys/switch-[id]
fltFabricPinTargetDown
Fault Code: F1088
Message
Pin target is a non-existent interface
Explanation
This fault typically occurs when a PinGroup has an unresolvable target.
Recommended Action
If you see this fault, take the following action:
Step 1 Check whether the PinGroup target is correctly provisioned.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFabricPinTargetDown
moClass: fabric:PinTarget
Affected MO: fabric/lan/lan-pin-group-[name]/target-[fabricId]
Affected MO: fabric/san/san-pin-group-[name]/target-[fabricId]
fltFabricEthLanEpOverlapping-vlan
Fault Code: F1090
Message
On Fabric: [switchId], Port: [slotId]/[aggrPortId]/[portId] following overlapping VLANs detected: [overlappingVlans]On Fabric: [switchId], Port: [slotId]/[portId] following overlapping VLANs detected: [overlappingVlans]
Explanation
This fault occurs when Overlapping Vlans occur due to mis configuration.
Recommended Action
Ports configured on Vlans belonging to a group should not intersect with other ports of different network group belonging to Vlans which overlap.
Fault Details
Cause: configuration-error
mibFaultName: fltFabricEthLanEpOverlappingVlan
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
fltFabricEthLanPcOverlapping-vlan
Fault Code: F1091
Message
Overlapping VLANs detected on Fabric: [switchId], Port: [portId] in configured VLANs: [overlappingVlans]
Explanation
This fault occurs when Overlapping Vlans occur due to mis configuration.
Recommended Action
Ports configured on Vlans belonging to a group should not intersect with other ports of different network group belonging to Vlans which overlap.
Fault Details
Cause: configuration-error
mibFaultName: fltFabricEthLanPcOverlappingVlan
Affected MO: fabric/lan/[id]/pc-[portId]
fltFabricVlanMisconfigured-mcast-policy
Fault Code: F1095
Message
VLAN [name] multicast policy [mcastPolicyName] is non-default.
Explanation
This fault is raised when VLAN belonging to a Springfield fabric has a non-default multicast policy assigned to it.
Recommended Action
If you see this fault, take the following action:
Step 1 Un-assign multicast policy for the this vlan or change the multicast policy to default.
Step 2 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: vlan-mcast-policy-misconfigured
mibFaultName: fltFabricVlanMisconfiguredMcastPolicy
Affected MO: fabric/eth-estc/[id]/net-[name]
Affected MO: fabric/eth-estc/net-[name]
Affected MO: fabric/lan/[id]/net-[name]
Affected MO: fabric/lan/net-[name]
fltMgmtConnectionDisabled
Fault Code: F1097
Message
Management Connection [type] in server [id] is not operational
Explanation
This fault occurs when multiple management connections are acknowledegd.
Recommended Action
If you see this fault, take the following actions:
Step 1 Disable the management connection which is unused.
Step 2 If new management connection needs to be used, decommission and recommission server.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: another-connection-already-enabled
mibFaultName: fltMgmtConnectionDisabled
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/fex-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/switch-[id]/mgmt/mgmt-connection-[type]
fltMgmtConnectionUnused
Fault Code: F1098
Message
Management Connection [type] in server [id] is unused
Explanation
This fault occurs when a management connection is not enabel
Recommended Action
If you see this fault, you can enable the connection if none of the management connections are enabled. Else this can be ignored
Fault Details
mibFaultName: fltMgmtConnectionUnused
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/fex-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/switch-[id]/mgmt/mgmt-connection-[type]
fltMgmtConnectionUnsupportedConnectivity
Fault Code: F1099
Message
Unsupported connectivity for management connection [type] in server [id]
Explanation
This fault typically occurs because Cisco FPR Manager has detected that the physical connectivity of the management port of the server is unsupported.
Recommended Action
If you see this fault, take the following actions:
Step 1 Connect the management port/s of the rack mount server to the Fabric Extender/s
Step 2 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: unsupported-connectivity
mibFaultName: fltMgmtConnectionUnsupportedConnectivity
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/fex-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/switch-[id]/mgmt/mgmt-connection-[type]
fltCallhomeEpNoSnmpPolicyForCallhome
Fault Code: F1102
Message
FPR Manager cannot apply Callhome policy if SNMP Policy is not configured or if SNMP Syscontact has an empty value. The Callhome policy from FPR Central has not been applied.
Explanation
This fault typically occurs when FPR Manager receives an invalid configuration from FPR Central wherein Callhome is configured on FPR Central but there is no SNMP Syscontact defined locally.
Recommended Action
If you see this fault, please ensure that the SNMP Policy is configured on FPRM Manager, either locally or via FPR Central.
Fault Details
Cause: callhome-config-error
mibFaultName: fltCallhomeEpNoSnmpPolicyForCallhome
fltCapabilityCatalogueLoadErrors
Fault Code: F1103
Message
Load errors: File parse errors: [fileParseFailures], provider load failures: [providerLoadFailures], XML element load errors: [loadErrors].
Explanation
The capability catalog failed to load fully. This may be caused by either a faulty FPRM image or a faulty catalog image.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the version of the capability catalog.
Step 2 Contact Cisco TAC to see if there are known issues with the catalog and if there is a catalog image that will fix the known issues.
Fault Details
Cause: load-catalog-failed
mibFaultName: fltCapabilityCatalogueLoadErrors
moClass: capability:Catalogue
Affected MO: capabilities
fltExtmgmtArpTargetsArpTargetsNotValid
Fault Code: F1114
Message
Invalid ARP Targets configured for Management Interface Polling. Error: [configStatusMessage]
Explanation
This fault typically occurs because Cisco FPR Manager has detected an invalid ArpTargets Configuration.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that Arp target ip address and external management ip address are in the same subnet.
Step 2 Verify that Arp target ip address is not the same as ip address of this system’s fabric-interconnects.
Step 3 Verify that Arp target ip address is not the same as virtual IP Address.
Fault Details
Cause: arp-targets-config-error
mibFaultName: fltExtmgmtArpTargetsArpTargetsNotValid
moClass: extmgmt:ArpTargets
Affected MO: sys/extmgmt-intf-monitor-policy/arp-target-policy
fltExtpolClientGracePeriodWarning
Fault Code: F1211
Message
FPR domain [name] registered with FPR Central has entered into the grace period.
Explanation
A FPR domain is registered with FPR Central without having a license. This fault typically occurs if this FPR domain is registered with FPR Central after all default (and procured) licenses are assigned to other FPR domains.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the number of licenses installed and consumed on FPR Central. In the Cisco FPR Central GUI, you can access the licensing information from the Operations Management tab for the FPR Central. In the Cisco FPR Central CLI, you can access the licensing information by entering the show usage detail command under license scope from service-reg session.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: license-graceperiod-entered
mibFaultName: fltExtpolClientGracePeriodWarning
Affected MO: extpol/reg/clients/client-[id]
fltExtpolClientGracePeriodWarning2
Fault Code: F1212
Message
FPR Domain [name] registered with FPR Central is running in the grace period for more than 10 days
Explanation
This FPR domain is registered with FPR Central without having a license. This fault typically occurs if this FPR domain is registered with FPR Central after all default (and procured) licenses are assigned to other FPR domains.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the number of licenses installed and consumed on FPR Central. In the Cisco FPR Central GUI, you can access the licensing information from the Operations Management tab for the FPR Central. In the Cisco FPR Central CLI, you can access the licensing information by entering the show usage detail command under the license scope.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: license-graceperiod-10days
mibFaultName: fltExtpolClientGracePeriodWarning2
Affected MO: extpol/reg/clients/client-[id]
fltExtpolClientGracePeriodWarning3
Fault Code: F1213
Message
FPR Domain [name] registered with FPR Central is running in the grace period for more than 30 days
Explanation
This FPR Domain registered with FPR Central has been running in the grace period for more than 30 days. This fault typically occurs if this FPR domain is registered with FPR Central after all default (and procured) licenses are assigned to other FPR domains and the unlicensed FPR Domains have been running for more than 120 days.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the number of licenses installed and consumed on FPR Central. In the Cisco FPR Manager GUI, you can access the licensing information from the Operations Management tab for the FPR Central. In the Cisco FPR Central CLI, you can access the licensing information by entering the show usage detail command under the license scope.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: license-graceperiod-30days
mibFaultName: fltExtpolClientGracePeriodWarning3
Affected MO: extpol/reg/clients/client-[id]
fltExtpolClientGracePeriodWarning4
Fault Code: F1214
Message
FPR Domain [name] registered with FPR Central is running in the grace period for more than 60 days
Explanation
This FPR Domain registered with FPR Central has been running in the grace period for more than 60 days. This fault typically occurs if this FPR domain is registered with FPR Central after all default (and procured) licenses are assigned to other FPR domains and the unlicensed FPR Domains have been running for more than 60 days.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the number of licenses installed and consumed on FPR Central. In the Cisco FPR Central GUI, you can access the licensing information from the Operations Management tab for the FPR Central. In the Cisco FPR Central CLI, you can access the licensing information by entering the show usage detail command under the license scope.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: license-graceperiod-60days
mibFaultName: fltExtpolClientGracePeriodWarning4
Affected MO: extpol/reg/clients/client-[id]
fltExtpolClientGracePeriodWarning5
Fault Code: F1215
Message
FPR Domain [name] registered with FPR Central is running in the grace period for more than 90 days
Explanation
This FPR Domain registered with FPR Central has been running in the grace period for more than 90 days. This fault typically occurs if this FPR domains is registered with FPR Central after all default (and procured) licenses are assigned to other FPR domains and the unlicensed FPR Domains have been running for more than 90 days.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the number of licenses installed and consumed by FPR Central. In the Cisco FPR Central GUI, you can access the licensing information from the Operations Management tab for the FPR Central. In the Cisco FPR Central CLI, you can access the licensing information by entering the show usage detail command under the license scope.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: license-graceperiod-90days
mibFaultName: fltExtpolClientGracePeriodWarning5
Affected MO: extpol/reg/clients/client-[id]
fltExtpolClientGracePeriodWarning6
Fault Code: F1216
Message
FPR Domain [name] registered with FPR Central is running in the grace period for more than 119 days
Explanation
This FPR Domain registered with FPR Central has been running in the grace period for more than 119 days. This fault typically occurs if this FPR domain is registered with FPR Central after all default (and procured) licenses are assigned to other FPR domains and the unlicensed FPR Domains have been running for more than 119 days.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the number of licenses installed and consumed on FPR Central. In the Cisco FPR Central GUI, you can access the licensing information from the Operations Management tab for FPR Central. In the Cisco FPR Central CLI, you can access the licensing information by entering the show usage detail command under the license scope.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: license-graceperiod-119days
mibFaultName: fltExtpolClientGracePeriodWarning6
Affected MO: extpol/reg/clients/client-[id]
fltExtpolClientGracePeriodWarning7
Fault Code: F1217
Message
Grace period for FPR Domain [name] registered with FPR Central has expired. Please acquire a license for the same.
Explanation
This FPR Domain registered with FPR Central has been running in the grace period for more than 120 days. FPR domains are registered with FPR Central after all default (and procured) licenses are assigned to other FPR domains and the unlicensed FPR Domains have been running for more than 120 days. At this stage, the system licensing state is set to expired.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the number of licenses installed and consumed on FPR Central. In the Cisco FPR Central GUI, you can access the licensing information from the Operations Management tab for FPR Central. In the Cisco FPR Central CLI, you can access the licensing information by entering the show usage detail command under the license scope.
Step 2 Disable the unlicensed FPR Domains to bring the number of enabled Domains down to the number of total licenses.
Step 3 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC immediately to procure more licenses.
Fault Details
Cause: license-graceperiod-expired
mibFaultName: fltExtpolClientGracePeriodWarning7
Affected MO: extpol/reg/clients/client-[id]
fltExtpolClientGracePeriodWarning1
Fault Code: F1218
Message
FPR Domain [name] is registered with FPR Central without a valid license.
Explanation
This FPR domain is registered with FPR Central without having a license. This fault typically occurs if this FPR domain is registered with FPR Central without the initial activation license and after all default licenses are assigned to other FPR domains.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check if the initial activation license is installed on FPR Central. In the Cisco FPR Central GUI, you can access the licensing information from the Operations Management tab for FPR Central. In the Cisco FPR Central CLI, you can access the licensing information by entering the show usage detail command under the license scope.
Step 2 Disable the unlicensed FPR Domains to bring the number of enabled Domains down to the number of total licenses.
Step 3 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC immediately to procure more licenses.
Fault Details
Cause: license-insufficient
mibFaultName: fltExtpolClientGracePeriodWarning1
Affected MO: extpol/reg/clients/client-[id]
fltStorageItemFilesystemIssues
Fault Code: F1219
Message
Partition [name] on fabric interconnect [id] has file system errors
Explanation
This fault occurs when the partition develops faults
Recommended Action
If you see this fault, take the following actions:
Step 1 Create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-degraded
mibFaultName: fltStorageItemFilesystemIssues
Affected MO: sys/switch-[id]/stor-part-[name]
fltPkiKeyRingModulus
Fault Code: F1222
Message
[name] Keyring’s RSA modulus is invalid.
Explanation
This fault occurs when RSA keyring is created without modulus set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: invalid-keyring-modulus
mibFaultName: fltPkiKeyRingModulus
Affected MO: sys/pki-ext/keyring-[name]
fltAaaOrgLocaleOrgNotPresent
Fault Code: F1223
Message
Locale Org [name] can’t be deployed. Error: [configStatusMessage]
Explanation
This fault typically occurs because Cisco FPR Manager has detected an unidentified org reference.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the org dn referenced in this Org is exists, if not create the same.
Fault Details
Cause: locale-org-config-error
mibFaultName: fltAaaOrgLocaleOrgNotPresent
Affected MO: sys/user-ext/locale-[name]/org-[name]
fltNetworkOperLevelExtraprimaryvlans
Fault Code: F1229
Message
Fabric Interconnect [id]: Number of primary vlans exceeds the max limit on the FI: Number of Primary Vlans: [primaryVlanCount] and Max primary vlans allowed: [maxPrimaryVlanCount]
Explanation
This fault occurs when the fabric interconnect has more number of primary vlans than what is supported.
Recommended Action
If you see this fault, take the following actions:
Step 1 It is recommended that operator should delete the extra primary vlans than are there in the FI. System may appear to be normally functioning even with these extra primary vlans in place. However there may be performance issues observed as the system is operating above the recommended scale limits..
Step 2 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: extra-primary-vlans
mibFaultName: fltNetworkOperLevelExtraprimaryvlans
moClass: network:OperLevel
Affected MO: sys/switch-[id]/oper-level
fltEquipmentHealthLedCriticalError
Fault Code: F1236
Message
Health LED of server [chassisId]/[slotId] shows error. Reason: [healthLedStateQualifier]Health LED of server [id] shows error. Reason: [healthLedStateQualifier]
Explanation
This fault is raised Blade LED changes to amber blinking
Recommended Action
If you see this fault, take the following actions:
Step 1 Read fault summary and determine course of action.
Fault Details
Cause: health-led-amber-blinking
mibFaultName: fltEquipmentHealthLedCriticalError
moClass: equipment:HealthLed
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/health-led
Affected MO: sys/chassis-[id]/blade-[slotId]/health-led
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/health-led
Affected MO: sys/chassis-[id]/health-led
Affected MO: sys/chassis-[id]/psu-[id]/health-led
Affected MO: sys/chassis-[id]/slot-[id]/health-led
Affected MO: sys/fex-[id]/health-led
Affected MO: sys/fex-[id]/psu-[id]/health-led
Affected MO: sys/fex-[id]/slot-[id]/health-led
Affected MO: sys/rack-unit-[id]/ext-board-[id]/health-led
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/health-led
Affected MO: sys/rack-unit-[id]/health-led
Affected MO: sys/rack-unit-[id]/psu-[id]/health-led
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/health-led
Affected MO: sys/switch-[id]/psu-[id]/health-led
fltEquipmentHealthLedMinorError
Fault Code: F1237
Message
Health LED of server [chassisId]/[slotId] shows error. Reason: [healthLedStateQualifier]Health LED of server [id] shows error. Reason: [healthLedStateQualifier]
Explanation
This fault is raised Blade LED changes to amber
Recommended Action
If you see this fault, take the following actions:
Step 1 Read fault summary and determine course of action.
Fault Details
mibFaultName: fltEquipmentHealthLedMinorError
moClass: equipment:HealthLed
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/health-led
Affected MO: sys/chassis-[id]/blade-[slotId]/health-led
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/health-led
Affected MO: sys/chassis-[id]/health-led
Affected MO: sys/chassis-[id]/psu-[id]/health-led
Affected MO: sys/chassis-[id]/slot-[id]/health-led
Affected MO: sys/fex-[id]/health-led
Affected MO: sys/fex-[id]/psu-[id]/health-led
Affected MO: sys/fex-[id]/slot-[id]/health-led
Affected MO: sys/rack-unit-[id]/ext-board-[id]/health-led
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/health-led
Affected MO: sys/rack-unit-[id]/health-led
Affected MO: sys/rack-unit-[id]/psu-[id]/health-led
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/health-led
Affected MO: sys/switch-[id]/psu-[id]/health-led
fltVnicEtherIfRemoteVlanUnresolvable
Fault Code: F1249
Message
The named vlan [name] for vNIC [name] cannot be resolved remotely
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: referenced-remote-vlan-unresolvable
mibFaultName: fltVnicEtherIfRemoteVlanUnresolvable
Affected MO: fabric/lan/network-sets/fabric-network-[name]/fabric-network-def-[name]/vm-network-def-[name]/if-[name]
Affected MO: fabric/lan/profiles/vnic-[name]/if-[name]
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/lan-conn-templ-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/ipc-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ipc-[name]/if-[name]
fltVnicEtherVirtualization-conflict
Fault Code: F1251
Message
Multiple connection policies cannot be assigned to the same Eth vNIC
Explanation
This fault occurs when multiple connection policies are assigned to the same vNIC.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check on the vNIC if different types of connection policies (dynamic/VMQ) are assigned. Keep only one type.
Step 2 Check on the vNIC through CLI if more than one connection policy of the same type is assigned. Keep only one connection policy.
Fault Details
Cause: multiple-connection-policies
mibFaultName: fltVnicEtherVirtualizationConflict
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]
fltLsIssuesIscsi-config-failed
Fault Code: F1252
Message
Service Profile [name] configuration failed due to iSCSI issue [iscsiConfigIssues]
Explanation
This fault typically occurs when Cisco FPR Manager Service Profile configuration failed due to iSCSI Config Issues.
Recommended Action
If you see this fault, take the following actions:
Step 1 Correct the Service Profile iSCSI Configuration as per the issue reported.
Step 2 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: configuration-failed
mibFaultName: fltLsIssuesIscsiConfigFailed
Affected MO: org-[name]/ls-[name]/config-issue
Affected MO: org-[name]/tier-[name]/ls-[name]/config-issue
fltStorageLocalDiskMissing
Fault Code: F1256
Message
Local disk [id] missing on server [chassisId]/[slotId]Local disk [id] missing on server [id]
Explanation
This fault occurs when a disk is missing.
Recommended Action
If you see this fault, take the following action:
Step 1 Insert the disk.
Fault Details
mibFaultName: fltStorageLocalDiskMissing
moClass: storage:LocalDisk
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]
fltStorageFlexFlashControllerInoperable
Fault Code: F1257
Message
FlexFlash Controller [id] on server [chassisId]/[slotId] is inoperable. Reason: [operQualifierReason] Status: [controllerHealth]FlexFlash Controller [id] on server [id] is inoperable. Reason: [operQualifierReason] Status: [controllerHealth]
Explanation
This fault occurs when the flexflash controller is inaccessible.
Recommended Action
If you see this fault, take the following action:
Step 1 If reported as Firmware Mismatch, update the CIMC and Board Controller firmware
Step 2 If reported as Fatal Error, reset the CIMC and update Board Controller firmware
Step 3 For PCI and mezz-based controllers, check the seating of the storage controller. If the problem persists, replace the controller
Fault Details
Cause: equipment-inoperable
mibFaultName: fltStorageFlexFlashControllerInoperable
moClass: storage:FlexFlashController
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-flexflash-[id]
Affected MO: sys/rack-unit-[id]/board/storage-flexflash-[id]
fltStorageFlexFlashCardInoperable
Fault Code: F1258
Message
FlexFlash Card [slotNumber] on server [chassisId]/[slotId] is inoperable. Reason: [operQualifierReason]FlexFlash Card [slotNumber] on server [id] is inoperable. Reason: [operQualifierReason]
Explanation
This fault occurs when the flexflash card is inaccessible.
Recommended Action
If you see this fault, take the following action:
Step 1 If reported as Write Protected, then remove write protection from the card
Step 2 If reported as Invalid Capacity, use an OS disk utility to delete/recreate the partitions
Step 3 If the above action did not resolve the issue, replace the card
Fault Details
Cause: equipment-inoperable
mibFaultName: fltStorageFlexFlashCardInoperable
moClass: storage:FlexFlashCard
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-flexflash-[id]/card-[slotNumber]
Affected MO: sys/rack-unit-[id]/board/storage-flexflash-[id]/card-[slotNumber]
fltStorageFlexFlashCardMissing
Fault Code: F1259
Message
FlexFlash Card [slotNumber] missing on server [chassisId]/[slotId]FlexFlash Card [slotNumber] missing on server [id]
Explanation
This fault occurs when a FlexFlash Card is missing.
Recommended Action
If you see this fault, take the following action:
Step 1 Insert the Card.
Fault Details
mibFaultName: fltStorageFlexFlashCardMissing
moClass: storage:FlexFlashCard
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-flexflash-[id]/card-[slotNumber]
Affected MO: sys/rack-unit-[id]/board/storage-flexflash-[id]/card-[slotNumber]
fltStorageFlexFlashVirtualDriveDegraded
Fault Code: F1260
Message
FlexFlash Virtual Drive RAID degraded on server [chassisId]/[slotId]. Reason: [raidState]FlexFlash Virtual Drive RAID degraded on server [id]. Reason: [raidState]
Explanation
This fault occurs when the flexflash raid is degraded.
Recommended Action
If you see this fault, take the following action:
Step 1 Re-acknowledge the server by setting the flexflash scrub policy to yes. Please note that this action will erase all data in the card(s)
Step 2 Verify the health of the controller/card(s). If the above action did not resolve the issue, replace the card(s)
Fault Details
Cause: equipment-degraded
mibFaultName: fltStorageFlexFlashVirtualDriveDegraded
moClass: storage:FlexFlashVirtualDrive
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-flexflash-[id]/vd-[id]
Affected MO: sys/rack-unit-[id]/board/storage-flexflash-[id]/vd-[id]
fltStorageFlexFlashVirtualDriveInoperable
Fault Code: F1261
Message
FlexFlash Virtual Drive on server [chassisId]/[slotId] is inoperable. Reason: [raidState]FlexFlash Virtual Drive on server [id] is inoperable. Reason: [raidState]
Explanation
This fault occurs when the flexflash virtual drive is inoperable.
Recommended Action
If you see this fault, take the following action:
Step 1 Re-acknowledge the server by setting the flexflash scrub policy to yes. Please note that this action will erase all data in the card(s)
Step 2 Verify the health of the controller/card(s). If the above action did not resolve the issue, replace the card(s)
Fault Details
Cause: equipment-inoperable
mibFaultName: fltStorageFlexFlashVirtualDriveInoperable
moClass: storage:FlexFlashVirtualDrive
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-flexflash-[id]/vd-[id]
Affected MO: sys/rack-unit-[id]/board/storage-flexflash-[id]/vd-[id]
fltStorageFlexFlashControllerUnhealthy
Fault Code: F1262
Message
FlexFlash Controller [id] on server [chassisId]/[slotId] is unhealthy. Reason: [operQualifierReason] Status: [controllerHealth]FlexFlash Controller [id] on server [id] is unhealthy. Reason: [operQualifierReason] Status: [controllerHealth]
Explanation
This fault occurs when the flexflash controller is unhealthy.
Recommended Action
If you see this fault, take the following action:
Step 1 If reported as Old Firmware/Firmware Mismatch, update the CIMC and Board Controller firmware, reboot the server
Step 2 Re-acknowledge the server by setting the flexflash scrub policy to yes. Please note that this action will erase all data in the card(s)
Step 3 Verify the health of the controller. If the above action did not resolve the issue, replace the card(s)
Fault Details
Cause: equipment-unhealthy
mibFaultName: fltStorageFlexFlashControllerUnhealthy
moClass: storage:FlexFlashController
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-flexflash-[id]
Affected MO: sys/rack-unit-[id]/board/storage-flexflash-[id]
fltAaaProviderGroupProvidergroupsize
Fault Code: F1279
Message
For [dn]: Server Group [name] has [size] provider references. Authentication might fail, if this provider group is used with auth-domain.
Explanation
This fault typically occurs because Cisco FPR Manager has detected provider-group with 0 provider references..
Recommended Action
If you see this fault, take the following actions:
Step 1 Need to delete the provider group which does not have any provider references.
Step 2 Or Add provider references to provider group.
Fault Details
Cause: provider-group-size-empty
mibFaultName: fltAaaProviderGroupProvidergroupsize
moClass: aaa:ProviderGroup
Affected MO: sys/ldap-ext/providergroup-[name]
Affected MO: sys/radius-ext/providergroup-[name]
Affected MO: sys/tacacs-ext/providergroup-[name]
fltFirmwareAutoSyncPolicyDefaultHostPackageMissing
Fault Code: F1284
Message
Default host firmware package is missing or deleted.
Explanation
This fault typically occurs for the following reasons: when Auto Firmware Sync Policy is set Auto-acknowledge or User-acknowledge and default host firmware pack is not available.
- Auto Firmware Sync is not happening.
- Default host firmware package is missing or deleted.
Recommended Action
If you see this fault, take the following actions:
Step 1 Go to Servers tab and expand policies node. Select Host Firmware Packages under policies node.
Step 2 If the FSM failed, review the error message in the FSM.
Step 3 Create a host firmware package with name ’default’. If the problem persists, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: default-hostpack-missing
mibFaultName: fltFirmwareAutoSyncPolicyDefaultHostPackageMissing
moClass: firmware:AutoSyncPolicy
Affected MO: org-[name]/fw-auto-sync
fltFabricPooledVlanNamedVlanUnresolved
Fault Code: F1306
Message
VLAN [name] for VLAN group [name] cannot be resolved to any existing vlans.
Explanation
This fault typically occurs when a named VLAN in VLAN group cannot be resolved to any existing vlans.
Recommended Action
If you see this fault, take the following action:
Step 1 Create VLAN.
Step 2 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: named-vlan-unresolved
mibFaultName: fltFabricPooledVlanNamedVlanUnresolved
moClass: fabric:PooledVlan
Affected MO: fabric/lan/[id]/net-group-[name]/net-[name]
Affected MO: fabric/lan/net-group-[name]/net-[name]
fltExtvmmVMNDRefVmNetworkReferenceIncorrect
Fault Code: F1320
Message
VM Network [name] references [vmNetworkDefName] that is already being referenced by another VM Network
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: vm-network-reference-incorrect
mibFaultName: fltExtvmmVMNDRefVmNetworkReferenceIncorrect
Affected MO: fabric/lan/vm-network-sets/vm-network-[name]/vm-network-def-ref[name]
fltExtmgmtNdiscTargetsNdiscTargetsNotValid
Fault Code: F1321
Message
Invalid NDISC Targets configured for Management Interface Polling. Error: [configStatusMessage]
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: ndisc-targets-config-error
mibFaultName: fltExtmgmtNdiscTargetsNdiscTargetsNotValid
moClass: extmgmt:NdiscTargets
Affected MO: sys/extmgmt-intf-monitor-policy/ndisc-target-policy
fltFirmwareBootUnitPowerCycleRequired
Fault Code: F1325
Message
Board controller upgraded, manual a/c power cycle required on server [serverId]
Explanation
None set.
Recommended Action
If you see this fault, take the following actions:
Step 1 Power cycle the board controller.
Fault Details
Cause: board-ctrl-upgraded
mibFaultName: fltFirmwareBootUnitPowerCycleRequired
moClass: firmware:BootUnit
Affected MO: capabilities/ep/mgmt-ext/fw-boot-def/bootunit-[type]
Affected MO: capabilities/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/graphics-card-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/os-ctrl/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/epmfpga-[slot]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/fpga/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/rommon/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/fex-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/os-ctrl/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/graphics-card-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/os-ctrl/fw-boot-def/bootunit-[type]
Affected MO: sys/switch-[id]/mgmt/fw-boot-def/bootunit-[type]
fltMgmtControllerUnsupportedDimmBlacklisting
Fault Code: F1328
Message
Dimm blacklisting is not supported on server [chassisId]/[slotId]Dimm blacklisting is not supported on server [id]
Explanation
This fault typically occurs when the CIMC firmware on a server is an earlier release than Cisco FPR, Release 2.2.
Recommended Action
If you see this fault, consider upgrading the CIMC firmware, and the entire Cisco FPR instance if necessary, to Cisco FPR, Release 2.2 or later.
Fault Details
Cause: incompatible-server-firmware
mibFaultName: fltMgmtControllerUnsupportedDimmBlacklisting
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt
Affected MO: sys/chassis-[id]/slot-[id]/mgmt
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt
Affected MO: sys/fex-[id]/mgmt
Affected MO: sys/fex-[id]/slot-[id]/mgmt
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt
Affected MO: sys/rack-unit-[id]/boardController/mgmt
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt
Affected MO: sys/rack-unit-[id]/mgmt
Affected MO: sys/switch-[id]/mgmt
fltFabricEthLanEpUdldLinkDown
Fault Code: F1358
Message
UDLD state for ether port [slotId]/[aggrPortId]/[portId] on fabric interconnect [switchId] is: [udldOperState].UDLD state for ether port [slotId]/[portId] on fabric interconnect [switchId] is: [udldOperState].
Explanation
This fault occurs when an ethernet uplink port is unidirectional connected.
Recommended Action
If you see this fault, take the following action:
Step 1 Check the tx and rx connection of the uplink port.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFabricEthLanEpUdldLinkDown
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
fltFabricEthLanPcEpUdldLinkDown
Fault Code: F1359
Message
UDLD state for ether port [slotId]/[aggrPortId]/[portId] on fabric interconnect [switchId] is: [udldOperState].UDLD state for ether port [slotId]/[portId] on fabric interconnect [switchId] is: [udldOperState].
Explanation
This fault occurs when an ethernet uplink port-channel member is unidirectional connected.
Recommended Action
If you see this fault, take the following action:
Step 1 Check the tx and rx connection of the uplink port.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFabricEthLanPcEpUdldLinkDown
moClass: fabric:EthLanPcEp
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
fltEquipmentChassisInvalid-fru
Fault Code: F1407
Message
Chassis [id] has a empty value for FRU identity reported by CMC.
Explanation
This fault typically occurs when the FRU information for a chassis has empty value.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the capability catalog in Cisco FPR Manager is up to date. If necessary, update the catalog.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentChassisInvalidFru
moClass: equipment:Chassis
Affected MO: sys/chassis-[id]
fltEquipmentSwitchIOCardRemoved
Fault Code: F1408
Message
[side] FI IOM [chassisId]/[id] ([switchId]) is removed
Explanation
This fault typically occurs because an FI I/O module is removed from the chassis. In a cluster configuration, the chassis fails over to the other FI I/O module. For a standalone configuration, the chassis associated with the FI I/O module loses network connectivity. This is a critical fault because it can result in the loss of network connectivity and disrupt data traffic through the FI I/O module.
Recommended Action
If you see this fault, take the following actions:
Step 1 Reinsert the FI I/O module and configure the fabric-interconnect ports connected to it as server ports and wait a few minutes to see if the fault clears.
Step 2 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentSwitchIOCardRemoved
moClass: equipment:SwitchIOCard
Affected MO: sys/chassis-[id]/sw-slot-[id]
fltEquipmentSwitchIOCardThermalProblem
Fault Code: F1409
Message
[side] FI IOM [chassisId]/[id] ([switchId]) operState: [operState]
Explanation
This fault occurs when there is a thermal problem on an FI I/O module. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the FI I/O module.
Step 2 Review the Cisco FPR Site Preparation Guide to ensure the FI I/O modules have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco FPR chassis are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Replace faulty FI I/O modules.
Step 8 Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 9 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentSwitchIOCardThermalProblem
moClass: equipment:SwitchIOCard
Affected MO: sys/chassis-[id]/sw-slot-[id]
fltEquipmentSwitchIOCardThermalThresholdNonCritical
Fault Code: F1410
Message
[side] FI IOM [chassisId]/[id] ([switchId]) temperature: [thermal]
Explanation
This fault occurs when the temperature of an FI I/O module has exceeded a non-critical threshold value, but is still below the critical threshold. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
- If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the FI I/O module.
Step 2 Review the Cisco FPR Site Preparation Guide to ensure the chassis and FI I/O modules have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco FPR chassis and FI I/O module are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 8 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentSwitchIOCardThermalThresholdNonCritical
moClass: equipment:SwitchIOCard
Affected MO: sys/chassis-[id]/sw-slot-[id]
fltEquipmentSwitchIOCardThermalThresholdCritical
Fault Code: F1411
Message
[side] FI IOM [chassisId]/[id] ([switchId]) temperature: [thermal]
Explanation
This fault occurs when the temperature of an FI I/O module has exceeded a critical threshold value. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
- If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the FI I/O module.
Step 2 Review the Cisco FPR Site Preparation Guide to ensure the chassis and FI I/O modules have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco FPR chassis and FI I/O module are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Replace the faulty FI I/O modules.
Step 8 Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 9 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentSwitchIOCardThermalThresholdCritical
moClass: equipment:SwitchIOCard
Affected MO: sys/chassis-[id]/sw-slot-[id]
fltEquipmentSwitchIOCardThermalThresholdNonRecoverable
Fault Code: F1412
Message
[side] FI IOM [chassisId]/[id] ([switchId]) temperature: [thermal]
Explanation
This fault occurs when the temperature of an FI I/O module has been out of the operating range, and the issue is not recoverable. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
- If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the FI I/O module.
Step 2 Review the Cisco FPR Site Preparation Guide to ensure the chassis and FI I/O modules have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco FPR chassis and FI I/O module are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Replace the faulty FI I/O modules.
Step 8 Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 9 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentSwitchIOCardThermalThresholdNonRecoverable
moClass: equipment:SwitchIOCard
Affected MO: sys/chassis-[id]/sw-slot-[id]
fltEquipmentSwitchIOCardIdentity
Fault Code: F1414
Message
[side] FI IOM [chassisId]/[id] ([switchId]) has a malformed FRU
Explanation
This fault typically occurs when the FRU information for an FI I/O module is corrupted or malformed.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the capability catalog in Cisco FPR Manager is up to date. If necessary, update the catalog.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentSwitchIOCardIdentity
moClass: equipment:SwitchIOCard
Affected MO: sys/chassis-[id]/sw-slot-[id]
fltEquipmentSwitchIOCardCpuThermalThresholdCritical
Fault Code: F1415
Message
[side] FI IOM [chassisId]/[id] ([switchId]) processor temperature exceeded the limit
Explanation
This fault typically occurs when the processor temperature in FI-IOM exceeds the limit.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the FI I/O module.
Step 2 Review the Cisco FPR Site Preparation Guide to ensure the chassis and FI I/O modules have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco FPR chassis and FI I/O module are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Replace the faulty FI I/O modules.
Step 8 Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 9 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentSwitchIOCardCpuThermalThresholdCritical
moClass: equipment:SwitchIOCard
Affected MO: sys/chassis-[id]/sw-slot-[id]
fltPowerBudgetChassisPsuMixedMode
Fault Code: F1421
Message
Chassis [id] has a mix of high-line and low-line PSU input power sources.
Explanation
This fault occurs when there is a mix of high-line and low-line PSU input power source.
Recommended Action
If you see this fault, change all the PSU input power sources to have same mode
Fault Details
mibFaultName: fltPowerBudgetChassisPsuMixedMode
Affected MO: sys/chassis-[id]/blade-[slotId]/budget
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/budget
Affected MO: sys/chassis-[id]/budget
Affected MO: sys/rack-unit-[id]/budget
Affected MO: sys/rack-unit-[id]/ext-board-[id]/budget
fltNetworkElementRemoved
Fault Code: F1426
Message
Fabric Interconnect [id] operability: [operability]
Explanation
This fault occurs when the fabric interconnect is removed in a clustering setup.
Recommended Action
If you see this fault, take the following actions:
Step 1 Reinsert the removed fabric interconnect back into the chassis (applicable to FPR-Mini only).
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltNetworkElementRemoved
Affected MO: sys/switch-[id]
fltNetworkOperLevelExtrasecondaryvlans
Fault Code: F1432
Message
Fabric Interconnect [id]: Number of secondary vlans exceeds the max limit on the FI: Number of secondary vlans: [secondaryVlanCount] and Max secondary vlans allowed: [maxSecondaryVlanCount]
Explanation
This fault occurs when the fabric interconnect has more number of secondary vlans than what is supported.
Recommended Action
If you see this fault, take the following actions:
Step 1 It is recommended that operator should delete the extra secondary vlans that are there in the FI. System may appear to be normally functioning even with these extra secondary vlans in place. However there may be performance issues observed as the system is operating above the recommended scale limits..
Step 2 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: extra-secondary-vlans
mibFaultName: fltNetworkOperLevelExtrasecondaryvlans
moClass: network:OperLevel
Affected MO: sys/switch-[id]/oper-level
fltSwVlanExtrasecondaryvlansperprimary
Fault Code: F1433
Message
Number of secondary vlans associated with the primary vlan [id] in Fabric Interconnect [switchId] exceeds the max limit: Number of secondary vlans: [secVlanPerPrimaryVlanCount] and Max secondary vlans allowed in a primary vlan: 30
Explanation
This fault occurs when the fabric interconnect has more number of secondary vlans per primary vlan than what is supported.
Recommended Action
If you see this fault, take the following actions:
Step 1 It is recommended that operator should delete the extra secondary vlans on this primary vlan that are there in the FI. System may appear to be normally functioning even with these extra secondary vlans on this primary vlan in place. However there may be performance issues observed as the system is operating above the recommended scale limits..
Step 2 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: extra-secondary-vlans-per-primary
mibFaultName: fltSwVlanExtrasecondaryvlansperprimary
Affected MO: fabric/lan/profiles/vnic-[name]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/fex-[id]/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/fex-[id]/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/fex-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/fex-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/switch-[id]/access-eth/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/access-eth/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/access-eth/slot-[slotId]-aggr-port-[aggrPortId]/fcoesan-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-eth/ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-eth/ethestc-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-eth/pc-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-eth/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-eth/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-eth/slot-[slotId]-aggr-port-[aggrPortId]/fcoesan-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-eth/vlan-[id]
Affected MO: sys/switch-[id]/border-fc/fcoesan-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-fc/fcoesan-pc-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-fc/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-fc/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-fc/slot-[slotId]-aggr-port-[aggrPortId]/fcoesan-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-fc/vlan-[id]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/pc-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesan-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/vc-[id]/vlan-[id]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/vlan-[id]
Affected MO: sys/switch-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/switch-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/switch-[id]/phys/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/phys/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/phys/slot-[slotId]-aggr-port-[aggrPortId]/fcoesan-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/ssp-lanmon-eth/ssp-mon-session[name]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/ssp-lanmon-eth/ssp-mon-session[name]/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/ssp-lanmon-eth/ssp-mon-session[name]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesan-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/tbh/border-eth/ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/tbh/border-eth/ethestc-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/tbh/border-eth/pc-[portId]/vlan-[id]
Affected MO: sys/tbh/border-eth/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/tbh/border-eth/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/tbh/border-eth/slot-[slotId]-aggr-port-[aggrPortId]/fcoesan-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/tbh/border-eth/vlan-[id]
fltMgmtBackupPolicyConfigConfiguration backup outdated
Fault Code: F1437
Message
Config backup may be outdated
Explanation
This fault occurs when last backup configuration is taken long back
Recommended Action
If you see this fault, take the following actions:
Step 1 Please take a configuration backup
Fault Details
Cause: config-backup-outdated
mibFaultName: fltMgmtBackupPolicyConfigConfigurationBackupOutdated
moClass: mgmt:BackupPolicyConfig
Affected MO: sys/bkup-policy-cfg
fltFirmwareStatusCimcFirmwareMismatch
Fault Code: F1441
Message
Aggregate blade CIMC firmware mismatch. Firmware: [cimcVersion]
Explanation
This fault typically occurs when the CIMC firmware image on master and slave node in an aggregate blade does not match.
Recommended Action
Update and activate master and slave CIMC to same firmware version.
Fault Details
Cause: cimc-firmware-mismatch
mibFaultName: fltFirmwareStatusCimcFirmwareMismatch
Affected MO: sys/chassis-[id]/blade-[slotId]/fw-status
Affected MO: sys/chassis-[id]/slot-[id]/fw-status
Affected MO: sys/fex-[id]/slot-[id]/fw-status
Affected MO: sys/fw-status
Affected MO: sys/rack-unit-[id]/fw-status
Affected MO: sys/switch-[id]/fw-status
fltFirmwareStatusPldFirmwareMismatch
Fault Code: F1442
Message
Aggregate blade board controller firmware mismatch. Firmware: [pldVersion]
Explanation
This fault typically occurs when the board controller firmware image on master and slave node in an aggregate blade does not match.
Recommended Action
Update master and slave board controller to same firmware version.
Fault Details
Cause: pld-firmware-mismatch
mibFaultName: fltFirmwareStatusPldFirmwareMismatch
Affected MO: sys/chassis-[id]/blade-[slotId]/fw-status
Affected MO: sys/chassis-[id]/slot-[id]/fw-status
Affected MO: sys/fex-[id]/slot-[id]/fw-status
Affected MO: sys/fw-status
Affected MO: sys/rack-unit-[id]/fw-status
Affected MO: sys/switch-[id]/fw-status
fltVnicEtherVirtualization-netflow-conflict
Fault Code: F1443
Message
Netflow and VMQ/SRIOV-USNIC policies cannot be assigned to the same Eth vNIC
Explanation
This fault typically occurs when a netflow src vnic is made a USNIC or VMQ vnic
Recommended Action
If you see this fault, take the following actions:
Step 1 Remove the vnic from a netflow session or remove the usnic/vmq policy
Step 2 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: multiple-connection-policies
mibFaultName: fltVnicEtherVirtualizationNetflowConflict
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]
fltSysdebugLogExportStatusLogExportFailure
Fault Code: F1444
Message
Log export to remote server failed from [switchId]:[exportFailureReason]
Explanation
This fault occurs when Cisco Firepower Manager cannot transfer a log file to a remote server. This is typically the result of one of the following issues:
- The remote server is not accessible.
- One or more of the parameters for the remote server that are specified for the log export target, such as path, username, password, ssh-key and server name, are incorrect.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify the connectivity to the remote server.
Step 2 Verify the path information of the remote server.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltSysdebugLogExportStatusLogExportFailure
moClass: sysdebug:LogExportStatus
Affected MO: sys/sysdebug/log-export-policy/log-export-status-[switchId]
fltLsServerSvnicNotPresent
Fault Code: F1459
Message
Service profile [name] does not contain service vnics for netflow.
Explanation
The service profile does not have service vnics, hence netflow will not function on this server. This fault typically occurs as a result of one of the following issues:
- Service profile has maximum number of vnics already created, hence cannot accomodate service vnics required for netflow.
Recommended Action
If you see this fault, take the following actions:
Step 1 If you have already enabled netflow, please reduce the number of vnics on the SP to accomodate service vnics.
Step 2 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltLsServerSvnicNotPresent
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]
fltLsIssuesKvmPolicyUnsupported
Fault Code: F1460
Message
Kvm mgmt policy not supported by current CIMC version
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: unsupported-cimc-firmware
mibFaultName: fltLsIssuesKvmPolicyUnsupported
Affected MO: org-[name]/ls-[name]/config-issue
Affected MO: org-[name]/tier-[name]/ls-[name]/config-issue
fltComputeABoardThermalProblem
Fault Code: F1461
Message
Motherboard [faultQualifier] of server [chassisId]/[slotId] (service profile: [assignedToDn]) thermal: [thermal]Motherboard of server [id] (service profile: [assignedToDn]) thermal: [thermal]
Explanation
This fault typically occurs when the motherboard thermal sensors on a server detect a problem.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the server fans are working properly.
Step 2 Wait for 24 hours to see if the problem resolves itself.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltComputeABoardThermalProblem
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]
Affected MO: sys/rack-unit-[id]/board
Affected MO: sys/rack-unit-[id]/ext-board-[id]
fltComputeABoardPowerUsageProblem
Fault Code: F1462
Message
Motherboard [faultQualifier] of server [chassisId]/[slotId] (service profile: [assignedToDn]) powerUsage: [powerUsage]Motherboard of server [id] (service profile: [assignedToDn]) powerUsage: [powerUsage]
Explanation
This fault typically occurs when the motherboard power consumption exceeds certain threshold limits. At that time the power usage sensors on a server detect a problem.
Recommended Action
If you see this fault, take the following actions:
Step 1 Create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltComputeABoardPowerUsageProblem
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]
Affected MO: sys/rack-unit-[id]/board
Affected MO: sys/rack-unit-[id]/ext-board-[id]
fltComputeABoardMotherBoardVoltageThresholdUpperNonRecoverable
Fault Code: F1463
Message
Motherboard input voltage(12V/5V/3V) in server [id] is [voltage]Motherboard [faultQualifier] input voltage(12V/5V/3V) in server [chassisId]/[slotId] is [voltage]
Explanation
This fault is raised when one or more motherboard input voltages has become too high and is unlikely to recover.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltComputeABoardMotherBoardVoltageThresholdUpperNonRecoverable
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]
Affected MO: sys/rack-unit-[id]/board
Affected MO: sys/rack-unit-[id]/ext-board-[id]
fltComputeABoardMotherBoardVoltageThresholdLowerNonRecoverable
Fault Code: F1464
Message
Motherboard input voltage(12V/5V/3V) in server [id] is [voltage]Motherboard [faultQualifier] input voltage(12V/5V/3V) in server [chassisId]/[slotId] is [voltage]
Explanation
This fault is raised when one or more motherboard input voltages has dropped too low and is unlikely to recover.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltComputeABoardMotherBoardVoltageThresholdLowerNonRecoverable
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]
Affected MO: sys/rack-unit-[id]/board
Affected MO: sys/rack-unit-[id]/ext-board-[id]
fltComputeABoardMotherBoardVoltageUpperThresholdCritical
Fault Code: F1465
Message
Motherboard input voltage(12V/5V/3V) in server [id] is [voltage]Motherboard [faultQualifier] input voltage(12V/5V/3V) in server [chassisId]/[slotId] is [voltage]
Explanation
This fault is raised when one or more motherboard input voltages has crossed upper critical thresholds.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltComputeABoardMotherBoardVoltageUpperThresholdCritical
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]
Affected MO: sys/rack-unit-[id]/board
Affected MO: sys/rack-unit-[id]/ext-board-[id]
fltComputeABoardMotherBoardVoltageLowerThresholdCritical
Fault Code: F1466
Message
Motherboard input voltage(12V/5V/3V) in server [id] is [voltage]Motherboard [faultQualifier] input voltage(12V/5V/3V) in server [chassisId]/[slotId] is [voltage]
Explanation
This fault is raised when one or more motherboard input voltages has crossed lower critical thresholds.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltComputeABoardMotherBoardVoltageLowerThresholdCritical
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]
Affected MO: sys/rack-unit-[id]/board
Affected MO: sys/rack-unit-[id]/ext-board-[id]
fltCimcvmediaActualMountEntryVmediaMountFailed
Fault Code: F1467
Message
Server [chassisId]/[slotId] (service profile: [assignedToDn]) vmedia mapping [mappingName] has failed.Server [id] (service profile: [assignedToDn]) vmedia mapping [mappingName] has failed.
Explanation
None set.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the mount related details(remote server ip, port, path & file is reachable) and reack the server.
Fault Details
Cause: vmedia-mount-inaccessible
mibFaultName: fltCimcvmediaActualMountEntryVmediaMountFailed
moClass: cimcvmedia:ActualMountEntry
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/fex-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/rack-unit-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/switch-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
fltFabricVlanPrimaryVlanMissingForIsolated
Fault Code: F1468
Message
Primary Vlan can not be resolved for isolated vlan [name]
Explanation
This fault typically occurs when Cisco FPR Manager encounters a problem resolving the primary VLAN ID corresponding to a particular isolated VLAN.
Recommended Action
If you see this fault, take the following actions:
Step 1 Associate the isolated VLAN with a valid primary VLAN.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: primary-vlan-missing-for-isolated
mibFaultName: fltFabricVlanPrimaryVlanMissingForIsolated
Affected MO: fabric/eth-estc/[id]/net-[name]
Affected MO: fabric/eth-estc/net-[name]
Affected MO: fabric/lan/[id]/net-[name]
Affected MO: fabric/lan/net-[name]
fltFabricVlanPrimaryVlanMissingForCommunity
Fault Code: F1469
Message
Primary Vlan can not be resolved for community vlan [name]
Explanation
This fault typically occurs when Cisco FPR Manager encounters a problem resolving the primary VLAN ID corresponding to a particular community VLAN.
Recommended Action
If you see this fault, take the following actions:
Step 1 Associate the community VLAN with a valid primary VLAN.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: primary-vlan-missing-for-community
mibFaultName: fltFabricVlanPrimaryVlanMissingForCommunity
Affected MO: fabric/eth-estc/[id]/net-[name]
Affected MO: fabric/eth-estc/net-[name]
Affected MO: fabric/lan/[id]/net-[name]
Affected MO: fabric/lan/net-[name]
fltFabricVlanMismatch-a
Fault Code: F1470
Message
VLAN [name] has [overlapStateForA] with another vlan under lan-cloud/appliance-cloud for the fabric interconnect A
Explanation
This fault typically occurs when private vlan properties of VLAN under one cloud conflicts with the private vlan properties of VLAN under another cloud for the fabric interconnect A. The cloud here means either a LAN cloud or an appliance cloud. This issue can stop the usage of this vlan.
Recommended Action
If you see this fault, take the following action:
Step 1 Check the sharing property of the VLAN under both clouds and fabric A referred by its VLAN ID.
Step 2 If the sharing property of the VLAN does not match with the VLAN on the other cloud, then change the sharing property of either of the VLANs, so that it matches with each other.
Step 3 If the VLAN is a isolated/community vlan, check the pubnwname property of the VLAN under both clouds referred by its VLAN ID.
Step 4 If the pubnwname property of the isolated/community VLAN does not match with the isolated/community VLAN on the other cloud, then change the pubnwname property of either of the VLANs, so that it matches with each other.
Step 5 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFabricVlanMismatchA
Affected MO: fabric/eth-estc/[id]/net-[name]
Affected MO: fabric/eth-estc/net-[name]
Affected MO: fabric/lan/[id]/net-[name]
Affected MO: fabric/lan/net-[name]
fltFabricVlanMismatch-b
Fault Code: F1471
Message
VLAN [name] has [overlapStateForB] with another vlan under lan-cloud/appliance-cloud for the fabric interconnect B
Explanation
This fault typically occurs when private vlan properties of VLAN under one cloud conflicts with the private vlan properties of VLAN under another cloud for the fabric interconnect B. The cloud here means either a LAN cloud or an appliance cloud. This issue can stop the usage of this vlan.
Recommended Action
If you see this fault, take the following action:
Step 1 Check the sharing property of the VLAN under both clouds and fabric B referred by its VLAN ID.
Step 2 If the sharing property of the VLAN does not match with the VLAN on the other cloud, then change the sharing property of either of the VLANs, so that it matches with each other.
Step 3 If the VLAN is a isolated/community vlan, check the pubnwname property of the VLAN under both clouds referred by its VLAN ID.
Step 4 If the pubnwname property of the isolated/community VLAN does not match with the isolated/community VLAN on the other cloud, then change the pubnwname property of either of the VLANs, so that it matches with each other.
Step 5 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFabricVlanMismatchB
Affected MO: fabric/eth-estc/[id]/net-[name]
Affected MO: fabric/eth-estc/net-[name]
Affected MO: fabric/lan/[id]/net-[name]
Affected MO: fabric/lan/net-[name]
fltFabricVlanErrorAssocPrimary
Fault Code: F1472
Message
VLAN [name] is in error state because the associated primary vlan [assocPrimaryVlanState]
Explanation
This fault typically occurs when there is an error in associated primary vlan of a secondary VLAN. This issue can stop the usage of this vlan.
Recommended Action
If you see this fault, take the following action:
Step 1 Check the pubnwname property of the VLAN.
Step 2 If the pubnwname is not given or refers to a non-existing primary vlan, give a name of a primary vlan which is in good state.
Step 3 If the pubnwname refers to a vlan which is not a primary vlan, then either change the referred vlan to be a primary vlan or give a different primary vlan.
Step 4 If the pubnwname refers to a valid primary vlan, then check the state of the primary VLAN.
Step 5 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: vlan-error-assoc-primary
mibFaultName: fltFabricVlanErrorAssocPrimary
Affected MO: fabric/eth-estc/[id]/net-[name]
Affected MO: fabric/eth-estc/net-[name]
Affected MO: fabric/lan/[id]/net-[name]
Affected MO: fabric/lan/net-[name]
fltStorageMezzFlashLifeConfiguration-error
Fault Code: F1494
Message
Flash Life on server [chassisId]/[slotId] flashStatus: [flashStatus]
Explanation
This fault occurs when FPRM is not able to retrieve the Fusion-io life left due to an error.
Recommended Action
If you see this fault, take the following actions:
Step 1 Upgrade Fusion-io Firmware.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: configuration-error
mibFaultName: fltStorageMezzFlashLifeConfigurationError
moClass: storage:MezzFlashLife
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/flash-life-
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/flash-life-
fltStorageMezzFlashLifeDegraded
Fault Code: F1495
Message
Flash Life on server [chassisId]/[slotId] flashStatus: [flashStatus]
Explanation
This fault occurs when the Fusion-io life left is 10 percent or less.
Recommended Action
If you see this fault, take the following actions:
Step 1 Continue to monitor the the Fusion-io life left and if it reaches 0 percent, the adapter might revert to read-only.
Fault Details
Cause: equipment-degraded
mibFaultName: fltStorageMezzFlashLifeDegraded
moClass: storage:MezzFlashLife
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/flash-life-
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/flash-life-
fltStorageFlexFlashControllerMismatch
Fault Code: F1496
Message
FlexFlash Controller [id] on server [chassisId]/[slotId] has SD cards with different sizes.FlexFlash Controller [id] on server [id] has SD cards with different sizes.
Explanation
This fault occurs when the flexflash SD Cards dont match in size.
Recommended Action
If you see this fault, take the following action:
Step 1 Remove one of the existing cards and replace it with another card that has the same size as the unremoved one.
Fault Details
Cause: equipment-unhealthy
mibFaultName: fltStorageFlexFlashControllerMismatch
moClass: storage:FlexFlashController
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-flexflash-[id]
Affected MO: sys/rack-unit-[id]/board/storage-flexflash-[id]
fltStorageFlexFlashDriveUnhealthy
Fault Code: F1497
Message
FlexFlash Drive [id] on server [chassisId]/[slotId] is unhealthy. Reason: [operQualifierReason] Status: [operationState]FlexFlash Drive [id] on server [id] is unhealthy. Reason: [operQualifierReason] Status: [operationState]
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: equipment-unhealthy
mibFaultName: fltStorageFlexFlashDriveUnhealthy
moClass: storage:FlexFlashDrive
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-flexflash-[id]/card-[slotNumber]/drive-[name]
Affected MO: sys/rack-unit-[id]/board/storage-flexflash-[id]/card-[slotNumber]/drive-[name]
fltStorageFlexFlashCardUnhealthy
Fault Code: F1498
Message
FlexFlash Card [slotNumber] on server [chassisId]/[slotId] is unhealthy. Reason: [cardHealth]FlexFlash Card [slotNumber] on server [id] is unhealthy. Reason: [cardHealth]
Explanation
This fault occurs when the flexflash card is unhealthy.
Recommended Action
If you see this fault, take the following action:
Step 1 Re-acknowledge the server by setting the flexflash scrub policy to yes. Please note that this action will erase all data in the card(s)
Step 2 Verify the health of the card. If the above action did not resolve the issue, replace the card
Fault Details
Cause: equipment-unhealthy
mibFaultName: fltStorageFlexFlashCardUnhealthy
moClass: storage:FlexFlashCard
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-flexflash-[id]/card-[slotNumber]
Affected MO: sys/rack-unit-[id]/board/storage-flexflash-[id]/card-[slotNumber]
fltMgmtInterfaceNamedInbandVlanUnresolved
Fault Code: F1506
Message
[configMessage]
Explanation
This fault occurs if there is an issue in Inband interface configuration.
Recommended Action
If you see this fault check if the VLAN configured on Inband IP is created and the VLAN is present in the Inband Profile or IP address is configured
Fault Details
Cause: named-inband-vlan-unresolved
mibFaultName: fltMgmtInterfaceNamedInbandVlanUnresolved
Affected MO: org-[name]/ls-[name]/iface-[mode]
Affected MO: org-[name]/tier-[name]/ls-[name]/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/iface-[mode]
Affected MO: sys/fex-[id]/mgmt/iface-[mode]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/iface-[mode]
Affected MO: sys/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/mgmt/iface-[mode]
Affected MO: sys/switch-[id]/mgmt/iface-[mode]
fltMgmtInterfaceInbandUnsupportedServer
Fault Code: F1507
Message
[configMessage]
Explanation
This fault occurs if there is an issue in Inband interface configuration.
Recommended Action
If you see this fault check if the VLAN configured on Inband IP is created and the VLAN is present in the Inband Profile or IP address is configured
Fault Details
Cause: inband-unsupported-server
mibFaultName: fltMgmtInterfaceInbandUnsupportedServer
Affected MO: org-[name]/ls-[name]/iface-[mode]
Affected MO: org-[name]/tier-[name]/ls-[name]/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/iface-[mode]
Affected MO: sys/fex-[id]/mgmt/iface-[mode]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/iface-[mode]
Affected MO: sys/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/mgmt/iface-[mode]
Affected MO: sys/switch-[id]/mgmt/iface-[mode]
fltMgmtInterfaceInbandUnsupportedFirmware
Fault Code: F1508
Message
[configMessage]
Explanation
This fault occurs if there is an issue in Inband interface configuration.
Recommended Action
If you see this fault check if the VLAN configured on Inband IP is created and the VLAN is present in the Inband Profile or IP address is configured
Fault Details
Cause: unsupported-cimc-firmware
mibFaultName: fltMgmtInterfaceInbandUnsupportedFirmware
Affected MO: org-[name]/ls-[name]/iface-[mode]
Affected MO: org-[name]/tier-[name]/ls-[name]/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/iface-[mode]
Affected MO: sys/fex-[id]/mgmt/iface-[mode]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/iface-[mode]
Affected MO: sys/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/mgmt/iface-[mode]
Affected MO: sys/switch-[id]/mgmt/iface-[mode]
fltComputePhysicalAdapterMismatch
Fault Code: F1509
Message
Server [id] (service profile: [assignedToDn]) has invalid adapter combinatonServer [chassisId]/[slotId] (service profile: [assignedToDn]) has invalid adapter combination
Explanation
This fault typically occurs because Cisco FPR Manager has detected that the server has an invalid combination of Cisco VICs.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the valid adapter combinations are installed configuration.
Step 2 Reacknowledge the server.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltComputePhysicalAdapterMismatch
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/rack-unit-[id]
fltEquipmentSwitchCardAct2LiteFail
Fault Code: F1510
Message
Failed Identification Test in slot - [id] ([descr]). The module in this slot may not be a genuine Cisco product. Cisco warranties and support programs only apply to genuine Cisco products. If Cisco determines that your insertion of non-Cisco modules into a Cisco productvis the cause of a support issue, Cisco may deny support under your warranty or under a Cisco support program such as SmartNet.
Explanation
This fault occurs when the ACT2 chip fails.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltEquipmentSwitchCardAct2LiteFail
moClass: equipment:SwitchCard
Affected MO: sys/switch-[id]/slot-[id]
fltEquipmentTpmSlaveTpm
Fault Code: F1511
Message
Server [chassisId]/[slotId], has a Tpm present on the Slave Board.
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: tpm-on-slave-board
mibFaultName: fltEquipmentTpmSlaveTpm
Affected MO: sys/chassis-[id]/blade-[slotId]/board/Tpm-[id]
Affected MO: sys/rack-unit-[id]/board/Tpm-[id]
fltPoolElementDuplicatedAssigned
Fault Code: F1512
Message
ID is duplicated assigned for multiple servers(Check FPRC for details)
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: duplicated-assigned
mibFaultName: fltPoolElementDuplicatedAssigned
fltSwVlanPortNsResourceStatusWarning
Fault Code: F1519
Message
Total Available Vlan-Port Count on switch [switchId] is below 10%
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltSwVlanPortNsResourceStatusWarning
Affected MO: sys/switch-[id]/vlan-port-ns
fltNetworkElementMemoryerror
Fault Code: F1520
Message
Fabric Interconnect [id] memory less than expected! Total Memory: [totalMemory] and Expected Memory: [expectedMemory]
Explanation
This fault occurs when the total memory on FI is less than expected.
Recommended Action
If you see this fault, take the following actions:
Step 1 You will need to do a manual physical inspection of the DIMMs on the FI. Try removing and reinserting the DIMMs, and verify the Total Memory. If this does not resolve the issue, one of the DIMMs has gone bad and needs to be replaced.
Step 2 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltNetworkElementMemoryerror
Affected MO: sys/switch-[id]
fltMgmtPmonEntryFPRM process failure
Fault Code: F1541
Message
FPRM process [name] failed on FI [switchId]
Explanation
This fault occurs in an unlikely event of a Cisco FPR Manager process crash. Typically, the failed process restarts and recovers from the problem. Any pending operations are restarted after the process successfully restarts.
Recommended Action
If you see this fault and the process does not restart successfully, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: fprm-process-failure
mibFaultName: fltMgmtPmonEntryFPRMProcessFailure
Affected MO: sys/mgmt-entity-[id]/[name]
fltSmSlotSmaHeartbeat
Fault Code: F1545
Message
Security module [slotId] - network adapter 1 is not responding
Explanation
This fault occurs when a slot is not operationally up.
Recommended Action
If you see this fault, take the following actions:
Step 1 Reboot the Blade associated with the Slot
Fault Details
Cause: slot-not-responding
mibFaultName: fltSmSlotSmaHeartbeat
Affected MO: sec-svc/slot-[slotId]
fltSmSlotBladeNotWorking
Fault Code: F1546
Message
Security Module [slotId] is in failed state. Error: [errorMsg]
Explanation
This fault occurs when a blade discovery is failed or service profile association is failed.
Recommended Action
If you see this fault, take the following actions:
Step 1 Reboot the blade associated with the slot
Fault Details
mibFaultName: fltSmSlotBladeNotWorking
Affected MO: sec-svc/slot-[slotId]
fltSmSlotDiskFormatFailed
Fault Code: F1547
Message
Disk format is failed on slot [slotId]
Explanation
This fault occurs when a blade disk formatting is failed.
Recommended Action
If you see this fault, take the following actions:
Step 1 Reformat disk or need disk replacement
Fault Details
Cause: disk-format-failed
mibFaultName: fltSmSlotDiskFormatFailed
Affected MO: sec-svc/slot-[slotId]
fltSmSlotBladeSwap
Fault Code: F1548
Message
Blade swap detected on slot [slotId]
Explanation
This fault occurs during the blade swap.
Recommended Action
If you see this fault, take the following action:
Step 1 1. Insert the correct blade
Step 2 2. Reformat the disk
Fault Details
mibFaultName: fltSmSlotBladeSwap
Affected MO: sec-svc/slot-[slotId]
fltOsControllerFailedBladeBootup
Fault Code: F1568
Message
Slot [slotId], boot up failed - recovery in progress
Explanation
This fault occurs when blade failed to boot up.
Recommended Action
If you see this fault, do nothing because the blade will try to recover
Step 1 Reboot the Blade associated with the Slot
Fault Details
mibFaultName: fltOsControllerFailedBladeBootup
Affected MO: sys/chassis-[id]/blade-[slotId]/os-ctrl
Affected MO: sys/rack-unit-[id]/os-ctrl
fltOsControllerFailedBootupRecovery
Fault Code: F1569
Message
Slot [slotId], boot up failed - exceeded max number of retries
Explanation
This fault occurs when blade failed to boot up.
Recommended Action
If you see this fault, do the following:
Step 1 Reboot the Blade associated with the Slot
Fault Details
mibFaultName: fltOsControllerFailedBootupRecovery
Affected MO: sys/chassis-[id]/blade-[slotId]/os-ctrl
Affected MO: sys/rack-unit-[id]/os-ctrl
fltFirmwarePlatformPackBundleVersionMissing
Fault Code: F1595
Message
Platform version is empty in platform firmware package
Explanation
This fault typically occurs when the platform version is not set.
Recommended Action
If you see this fault, take the following actions:
Step 1 In the CLI, under scope org/fw-platform-pack, set the platform-bundle-vers to a desired or expected running platform version.
Fault Details
Cause: default-plaform-version-missing
mibFaultName: fltFirmwarePlatformPackBundleVersionMissing
moClass: firmware:PlatformPack
Affected MO: org-[name]/fw-platform-pack-[name]
fltSmSecSvcSwitchConfigFail
Fault Code: F1626
Message
Switch configuration failed for Logical Device. Error: [switchErrorMsg]
Explanation
This fault occurs when switch configuration fails for a LogicalDevice.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: switch-config-failed
mibFaultName: fltSmSecSvcSwitchConfigFail
fltSmLogicalDeviceIncompleteConfig
Fault Code: F1628
Message
Logical Device [name] is not configured correctly. [errorMsg]
Explanation
This fault occurs when a logical device is not configured correctly.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: logical-device-incomplete-configuration
mibFaultName: fltSmLogicalDeviceIncompleteConfig
moClass: sm:LogicalDevice
Affected MO: sec-svc/ld-[name]
fltSmLogicalDeviceLogicalDeviceError
Fault Code: F1629
Message
Error in Logical Device [name]. [errorMsg]
Explanation
This fault occurs when a logical device is in a non-terminal error state.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: logical-device-error
mibFaultName: fltSmLogicalDeviceLogicalDeviceError
moClass: sm:LogicalDevice
Affected MO: sec-svc/ld-[name]
fltEtherFtwPortPairBypass
Fault Code: F1638
Message
Port-pair [portName]-[peerPortName] in switch-bypass mode
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltEtherFtwPortPairBypass
moClass: ether:FtwPortPair
Affected MO: sys/switch-[id]/fail-to-wire/ftw-port-[slotId]-[aggrPortId]-[portId]-port-[peerSlotId]-[peerAggrPortId]-[peerPortId]
fltCommDateTimeCommNtpConfigurationFailed
Fault Code: F1661
Message
Ntp Configuration failed, please check the error message in Ntp host
Explanation
This fault typically occurs because all Ntp configuration failed adn the system is out of sync.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that whether at least one Ntp configuration succeeded.
Fault Details
mibFaultName: fltCommDateTimeCommNtpConfigurationFailed
Affected MO: sys/svc-ext/datetime-svc
fltSmConfigIssueLogicalDeviceConfigError
Fault Code: F1671
Message
[errorMsg]
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: logical-device-config-error
mibFaultName: fltSmConfigIssueLogicalDeviceConfigError
Affected MO: sec-svc/ld-[name]/config-issue-[moKey]
fltSmAppAppImageCorrupted
Fault Code: F1673
Message
The application image [appId] is corrupted
Explanation
This fault occurs when an application meta data cannot be reloaded.
Recommended Action
If you see this fault, take the following actions:
Step 1 Re-download the application from a trusted source
Fault Details
mibFaultName: fltSmAppAppImageCorrupted
Affected MO: sec-svc/app-[name]-[version]
Affected MO: sys-secsvc/slot-[slotId]/app-inst-[appInstId]/app-[name]-[version]
fltEquipmentXcvrNonSupportedXcvr
Fault Code: F1677
Message
The transceiver inserted in port Ethernet [slotId]/[aggrPortId]/[portId] is not a Cisco product. Cisco warranties and support programs only apply to genuine Cisco products. If Cisco determines that your insertion of non-Cisco modules into a Cisco product is the cause of a support issue, Cisco TAC reserves the right to deny support
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltEquipmentXcvrNonSupportedXcvr
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/transceiver
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/transceiver
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/transceiver
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/transceiver
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/transceiver
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/transceiver
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/transceiver
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/transceiver
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/transceiver
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/transceiver
fltFabricSspEthMonDelAllSessEnabled
Fault Code: F1679
Message
Packet Capture Session [name] was still enabled when delete-all-sessions was issued
Explanation
This fault occurs when user issues the delete-all-sessions command when one of the packet capture sessions is still enabled
Recommended Action
If you see this fault, take the following actions:
Step 1 Disable the enabled session
Step 2 Retry the delete-all-sessions command
Fault Details
mibFaultName: fltFabricSspEthMonDelAllSessEnabled
moClass: fabric:SspEthMon
Affected MO: fabric/ssppktcapmon/ssp-mon-[name]
fltIpsecConnectionIpsecConnInvalidKey
Fault Code: F1681
Message
Invalid keyring [keyring] for IPSec connection [name]
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: ipsec-config-error
mibFaultName: fltIpsecConnectionIpsecConnInvalidKey
moClass: ipsec:Connection
Affected MO: sys/ipsec-ext/conn-[name]
fltIpsecConnectionIpsecConnInvalidCert
Fault Code: F1682
Message
Invalid Cert of keyring [keyring] for IPSec connection [name]
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: ipsec-config-error
mibFaultName: fltIpsecConnectionIpsecConnInvalidCert
moClass: ipsec:Connection
Affected MO: sys/ipsec-ext/conn-[name]
fltIpsecAuthorityIpsecAuthorInvalidTp
Fault Code: F1683
Message
Invalid trustpoint [tpName] for IPSec
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: ipsec-config-error
mibFaultName: fltIpsecAuthorityIpsecAuthorInvalidTp
Affected MO: sys/ipsec-ext/author-[tpName]
fltSmHotfixHotfixInstallFailed
Fault Code: F1691
Message
Failed to install Hotfix [version] on [appName]-[identifier] in slot [slotId]. Error: [errorMsg]
Explanation
This fault occurs when hotfix installation fails.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: hotfix-install-failed
mibFaultName: fltSmHotfixHotfixInstallFailed
Affected MO: sec-svc/slot-[slotId]/app-inst-[appName]-[identifier]/hotfix-[version]
Affected MO: sec-svc/slot-[slotId]/app-inst-[appName]/hotfix-[version]
fltSmHotfixHotfixError
Fault Code: F1692
Message
Error in Hotfix [version] on appInstance [appName]-[identifier] in slot [slotId]. Error: [errorMsg]
Explanation
This fault occurs when hotfix is in a non-terminal error state.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltSmHotfixHotfixError
Affected MO: sec-svc/slot-[slotId]/app-inst-[appName]-[identifier]/hotfix-[version]
Affected MO: sec-svc/slot-[slotId]/app-inst-[appName]/hotfix-[version]
fltSmErrorError
Fault Code: F1693
Message
[operStr] failed on slot [slotId]:[errorMsg]
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltSmErrorError
Affected MO: sec-svc/slot-[slotId]/app-inst-[appName]-[identifier]/error-[moKey]
Affected MO: sec-svc/slot-[slotId]/app-inst-[appName]/error-[moKey]
fltSmCloudConnectorCloudRegistrationFailed
Fault Code: F1694
Message
Failed to register the device with the cloud. Error: [errorMessage]
Explanation
This fault occurs when registration of device with cloud fails.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: cloud-registration-failed
mibFaultName: fltSmCloudConnectorCloudRegistrationFailed
moClass: sm:CloudConnector
Affected MO: sys/cloud-connector
fltSmCloudConnectorCloudUnregistrationFailed
Fault Code: F1695
Message
Failed to unregister the device with the cloud. Error: [errorMessage]
Explanation
This fault occurs when unregistration of device with cloud fails.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: cloud-unregistration-failed
mibFaultName: fltSmCloudConnectorCloudUnregistrationFailed
moClass: sm:CloudConnector
Affected MO: sys/cloud-connector
fltSmUnsignedCspLicenseUnsignedCSPLicenseInstalled
Fault Code: F1716
Message
Unsigned CSP License Installed [licenseFileName]
Explanation
This fault occurs when Unsigned CSP License is installed on the system.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltSmUnsignedCspLicenseUnsignedCSPLicenseInstalled
moClass: sm:UnsignedCspLicense
Affected MO: sec-svc/unsigned-csp-license
fltSdLinkVnicConfigFail
Fault Code: F1717
Message
Failed to set the oper state for vnic(s) [failedCfgVnics].
Explanation
This fault occurs when the vnic for this link failed to be configured.
Recommended Action
If you see this fault, take the following actions:
Step 1 Failed to set the oper state for vnic(s)
Fault Details
Cause: vnic-config-failed
mibFaultName: fltSdLinkVnicConfigFail
Affected MO: sys-secsvc/ld-[name]/ldu-[slotId]/app-ldulink-[name]-[endpoint1AppInstId]-[endpoint2AppInstId]
Affected MO: sys-secsvc/ld-[name]/ldu-[slotId]/ext-ldulink-[slotId]-[aggrPortId]-[portId]-[appName]
Affected MO: sys-secsvc/ld-[name]/ldu-[slotId]/ext-ldulink-[slotId]-[aggrPortId]-[portId]-[appName]/sub-ldulink-[subId]
Affected MO: sys-secsvc/ld-[name]/ldu-[slotId]/sub-ldulink-[subId]
Affected MO: sys-secsvc/slot-[slotId]/app-inst-[appInstId]/ldu-[slotId]/app-ldulink-[name]-[endpoint1AppInstId]-[endpoint2AppInstId]
Affected MO: sys-secsvc/slot-[slotId]/app-inst-[appInstId]/ldu-[slotId]/ext-ldulink-[slotId]-[aggrPortId]-[portId]-[appName]
Affected MO: sys-secsvc/slot-[slotId]/app-inst-[appInstId]/ldu-[slotId]/ext-ldulink-[slotId]-[aggrPortId]-[portId]-[appName]/sub-ldulink-[subId]
Affected MO: sys-secsvc/slot-[slotId]/app-inst-[appInstId]/ldu-[slotId]/sub-ldulink-[subId]
fltNwctrlCardConfigOffline
Fault Code: F1718
Message
Network Module [slotId] taken offline by user. Please check audit-logs for user activity.
Explanation
This fault occurs when the switch card is powered down.
Recommended Action
If you see this fault, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltNwctrlCardConfigOffline
moClass: nwctrl:CardConfig
Affected MO: sys/switch-[id]/card-[slotId]
fltNwctrlCardConfigFailed
Fault Code: F1719
Message
Network Module [slotId] is in failed state. If new hardware is inserted, please ensure proper firmware is installed. Otherwise, please collect the detailed FPRM techsupport from the local-mgmt shell and contact Cisco.
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltNwctrlCardConfigFailed
moClass: nwctrl:CardConfig
Affected MO: sys/switch-[id]/card-[slotId]
fltNwctrlCardConfigError
Fault Code: F1720
Message
Network Module [slotId] is in error state. If new hardware is inserted, please ensure proper firmware is installed. Otherwise, please collect the detailed FPRM techsupport from the local-mgmt shell and contact Cisco.
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltNwctrlCardConfigError
moClass: nwctrl:CardConfig
Affected MO: sys/switch-[id]/card-[slotId]
fltNwctrlCardConfigOirFailed
Fault Code: F1721
Message
Network Module [slotId] is in failed state. Hot swap with a different type of module is not supported. Please reboot system.
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltNwctrlCardConfigOirFailed
moClass: nwctrl:CardConfig
Affected MO: sys/switch-[id]/card-[slotId]
fltNwctrlCardConfigOirInvalid
Fault Code: F1722
Message
Network Module [slotId] is in failed state. Hot swap of this type of module is not supported. Please reboot system.
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: module-oir-invalid
mibFaultName: fltNwctrlCardConfigOirInvalid
moClass: nwctrl:CardConfig
Affected MO: sys/switch-[id]/card-[slotId]
fltNwctrlCardConfigRemoval
Fault Code: F1723
Message
Network Module [slotId] removed. Please re-insert module or use acknowledge command to confirm module removal.
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltNwctrlCardConfigRemoval
moClass: nwctrl:CardConfig
Affected MO: sys/switch-[id]/card-[slotId]
fltNwctrlCardConfigMismatch
Fault Code: F1724
Message
Network Module [slotId] is of different type than previously inserted module in this slot. Please use acknowledge command to confirm module replacement.
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltNwctrlCardConfigMismatch
moClass: nwctrl:CardConfig
Affected MO: sys/switch-[id]/card-[slotId]
fltNwctrlCardConfigSupriseRemoval
Fault Code: F1725
Message
Network Module [slotId] removed when in online state. It is recommended to set module offline before removal. Please re-insert module or use acknowledge command to confirm module removal.
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: module-suprise-removal
mibFaultName: fltNwctrlCardConfigSupriseRemoval
moClass: nwctrl:CardConfig
Affected MO: sys/switch-[id]/card-[slotId]
fltFirmwareRunnableAdapterUpgradeRequired
Fault Code: F1729
Message
Adapter [id] on Security Module [slotId] requires a critical firmware upgrade. Please see Adapter Bootloader Upgrade instructions in the FXOS Release Notes posted with this release.
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: adapter-boot-upgrade-required
mibFaultName: fltFirmwareRunnableAdapterUpgradeRequired
moClass: firmware:Runnable
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fw-runnable
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fw-runnable
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fw-runnable
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fw-runnable
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fw-runnable
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fw-runnable
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/fw-runnable
Affected MO: sys/fex-[id]/mgmt/fw-runnable
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fw-runnable
Affected MO: sys/mgmt/fw-runnable
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fw-runnable
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fw-runnable
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fw-runnable
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fw-runnable
Affected MO: sys/rack-unit-[id]/mgmt/fw-runnable
Affected MO: sys/switch-[id]/mgmt/fw-runnable
fltSmClusterBootstrapCclSubnetNotSupported
Fault Code: F1732
Message
Customization Cluster Control Link Subnet is not supported by the application
Explanation
This fault occurs when Ccl Subnet is not in default value when customization not supported by application.
Recommended Action
If you see this fault, take the following actions:
Step 1 Upgrade application or set ccl Network to 0.0.0.0
Fault Details
Cause: ccl-subnet-not-supported
mibFaultName: fltSmClusterBootstrapCclSubnetNotSupported
moClass: sm:ClusterBootstrap
Affected MO: sec-svc/ld-[name]/cluster-bootstrap
fltSmAppInstanceFailedConversion
Fault Code: F1735
Message
Unrecoverable error during conversion of App Instance [appName]-[startupVersion] on slot [slotId] during FXOS upgrade
Explanation
This fault occurs if we could not automatically convert smAppInstance to smAppInstance2 during upgrade to Fairlop
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltSmAppInstanceFailedConversion
Affected MO: sec-svc/slot-[slotId]/app-inst-[appName]
fltSmAppInstance2AppNotResponding
Fault Code: F1736
Message
App Instance [appName]-[identifier] with version [runningVersion] on slot [slotId] is not responding
Explanation
This fault occurs when an app instance is not responding.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: appinstance-not-responding
mibFaultName: fltSmAppInstance2AppNotResponding
Affected MO: sec-svc/slot-[slotId]/app-inst-[appName]-[identifier]
fltSmAppInstance2AppInstallFailed
Fault Code: F1737
Message
Failed to install App Instance [appName]-[identifier] with version [startupVersion] on slot [slotId]. Error: [errorMsg]
Explanation
This fault occurs when an app instance installation fails.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: appinstance-install-failed
mibFaultName: fltSmAppInstance2AppInstallFailed
Affected MO: sec-svc/slot-[slotId]/app-inst-[appName]-[identifier]
fltSmAppInstance2AppStartFailed
Fault Code: F1738
Message
Failed to start App Instance [appName]-[identifier] with version [runningVersion] on slot [slotId]. Error: [errorMsg]
Explanation
This fault occurs when an app instance start fails.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: appinstance-start-failed
mibFaultName: fltSmAppInstance2AppStartFailed
Affected MO: sec-svc/slot-[slotId]/app-inst-[appName]-[identifier]
fltSmAppInstance2AppUpdateFailed
Fault Code: F1739
Message
Failed to update App Instance [appName]-[identifier] with version [startupVersion] on slot [slotId]. Error: [errorMsg]
Explanation
This fault occurs when an app instance updation fails.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: appinstance-update-failed
mibFaultName: fltSmAppInstance2AppUpdateFailed
Affected MO: sec-svc/slot-[slotId]/app-inst-[appName]-[identifier]
fltSmAppInstance2AppStopFailed
Fault Code: F1740
Message
Failed to stop App Instance [appName]-[identifier] with version [runningVersion] on slot [slotId]. Error: [errorMsg]
Explanation
This fault occurs when an app instance stop fails.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: appinstance-stop-failed
mibFaultName: fltSmAppInstance2AppStopFailed
Affected MO: sec-svc/slot-[slotId]/app-inst-[appName]-[identifier]
fltSmAppInstance2AppNotInstalled
Fault Code: F1741
Message
App Instance [appName]-[identifier] with version [startupVersion] on slot [slotId] is not installed. Error: [errorMsg]
Explanation
This fault occurs when an app instance is not installed.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: appinstance-not-installed
mibFaultName: fltSmAppInstance2AppNotInstalled
Affected MO: sec-svc/slot-[slotId]/app-inst-[appName]-[identifier]
fltSmAppInstance2AppInstanceError
Fault Code: F1742
Message
Error in App Instance [appName]-[identifier] with version [startupVersion] on slot [slotId]. [errorMsg]
Explanation
This fault occurs when an app instance is in a non-terminal error state.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltSmAppInstance2AppInstanceError
Affected MO: sec-svc/slot-[slotId]/app-inst-[appName]-[identifier]
fltSmAppInstance2AppInstanceUnsupported
Fault Code: F1743
Message
App Instance [appName]-[identifier] with version [startupVersion] on slot [slotId] is not supported in the current bundle. Error: [errorMsg]
Explanation
This fault occurs when an app instance is not supported in the current platform bundle
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: appinstance-unsupported
mibFaultName: fltSmAppInstance2AppInstanceUnsupported
Affected MO: sec-svc/slot-[slotId]/app-inst-[appName]-[identifier]
fltSmAppInstance2SoftwareIncompatible
Fault Code: F1744
Message
[versionIncompatibleErrorMgr]
Explanation
This fault occurs when this main app version is not compatible with decorator version or this decorator version is not compatible with main app version.
Recommended Action
If you see this fault, take the following actions:
Step 1 Remove data port decorator from logical device
Fault Details
Cause: software-version-incompatible
mibFaultName: fltSmAppInstance2SoftwareIncompatible
Affected MO: sec-svc/slot-[slotId]/app-inst-[appName]-[identifier]
fltNetworkElementSamconfig
Fault Code: F1750
Message
The Supervisor’s sam.config file stored in the /opt partition is not accessible
Explanation
This fault occurs when the Supervisor is not able to access the persistent store of the sam.config file. Attempts at modifying the admin password, Supervisor OOB IPv4/6 addresses, DNS server, and strong password enforcement may fail.
Recommended Action
If you see this fault in a non-Cleared state, take the following actions:
Step 1 Create a show tech-support fprm detail file and copy it to a remote loaction.
Step 2 Backup the existing configuration using the export-config feature and copy it to a remote location.
Step 3 Contact Cisco TAC.
Fault Details
mibFaultName: fltNetworkElementSamconfig
Affected MO: sys/switch-[id]
fltSmAppInstance2AppFaultState
Fault Code: F1757
Message
AppInstance [appName]-[identifier] with version [runningVersion] on slot [slotId] is in failed state. Error: [errorMsg]
Explanation
This fault occurs when AppInstance is in "fault" state.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: appinstance-fault-state
mibFaultName: fltSmAppInstance2AppFaultState
Affected MO: sec-svc/slot-[slotId]/app-inst-[appName]-[identifier]
fltSmExternalPortLinkConflictConfig
Fault Code: F1758
Message
The external-port-link [name] conflict with the application. [errorDescription]. To correct it, synchronize and remove the conflict sub-interface, save and deploy from Firepower Management Center. Remove and recreate external-port-link [name] from MIO, then, synchronize it again from Firepower Management Center.
Explanation
This fault occurs when an external-port-link has conflict with the application.
Recommended Action
If you see this fault, take the either of following two actions:
Step 1 Delete the conflict external-port-link from MIO, and use another sub-interface to create a new external-port-llink
Step 2 Sync in Firepower Management Center to get the new sub-interface
Step 1 Delete the conflict sub-interface from Firepower Management Center
Step 2 Save and deploy the changes from Firepower Management Center
Step 3 Delete the conflict external-port-link and recreate it again from MIO
Step 4 Sync again in Firepower Management Center to get the new sub-interface
Fault Details
Cause: external-port-link-conflict-configuration
mibFaultName: fltSmExternalPortLinkConflictConfig
moClass: sm:ExternalPortLink
Affected MO: sec-svc/ld-[name]/ext-portlink-[name]
fltSmSlotAdapter2NotResponding
Fault Code: F1760
Message
[errorMsg]
Explanation
This fault occurs if adapter 2 is not responding to heartbeats.
Recommended Action
If you see this fault, take the following actions:
Step 1 Reboot the security module associated with the slot
Fault Details
Cause: adapter-2-not-responding
mibFaultName: fltSmSlotAdapter2NotResponding
Affected MO: sec-svc/slot-[slotId]
fltSmHwCryptoHwCryptoNotOperable
Fault Code: F1761
Message
Hardware crypto is enabled but not operable on [appName]-[identifier]. Reason: HwCryptoVersion is ’[hwCryptoVersion]’.
Explanation
This fault occurs when admin state of hardware crypto is set to enabled but the instance does not support it, or there is a failure when retrieving the hardware crypto version.
Recommended Action
If you see this fault, take the following actions:
Step 1 Set admin state of hardware crypto to ’disabled’ to free the hardware crypto resource on the application instance
Fault Details
Cause: hardware-crypto-version-unsupported-or-failure
mibFaultName: fltSmHwCryptoHwCryptoNotOperable
Affected MO: sec-svc/slot-[slotId]/app-inst-[appName]-[identifier]/hwCrypto
Affected MO: sys-secsvc/slot-[slotId]/app-inst-[appInstId]/hwCrypto
fltPkiTpAutoImportTp-auto-import-failure
Fault Code: F1762
Message
TrustPoints Auto Import Failure.
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: invalid-tp-auto-import
mibFaultName: fltPkiTpAutoImportTpAutoImportFailure
moClass: pki:TpAutoImport
Affected MO: sys/pki-ext/tpAutoImport-
fltPkiTpAutoImportTp-auto-import-attempt
Fault Code: F1763
Message
Last TrustPoints Auto Import Attempt.
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltPkiTpAutoImportTpAutoImportAttempt
moClass: pki:TpAutoImport
Affected MO: sys/pki-ext/tpAutoImport-
fltPkiKeyRingEc
Fault Code: F1764
Message
[name] Keyring’s ECDSA elliptic-curve is invalid.
Explanation
This fault occurs when ECDSA keyring is created without elliptic-curve set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: invalid-keyring-ec
mibFaultName: fltPkiKeyRingEc
Affected MO: sys/pki-ext/keyring-[name]
fltCommTelemetryTelemetryRegistrationFailed
Fault Code: F1765
Message
Auto registration of device for telemetry failed. Error: [errorMessage]
Explanation
This fault occurs when registration of device with cloud fails for telemetry.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: telemetry-registration-failed
mibFaultName: fltCommTelemetryTelemetryRegistrationFailed
Affected MO: sys/svc-ext/telemetry
fltCommTelemetryTelemetryUnregistrationFailed
Fault Code: F1766
Message
Failed to unregister the device with the cloud. Error: [errorMessage]
Explanation
This fault occurs when unregistration of device with cloud fails.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: telemetry-unregistration-failed
mibFaultName: fltCommTelemetryTelemetryUnregistrationFailed
Affected MO: sys/svc-ext/telemetry
fltCommTelemetryTelemetryGetDataFailed
Fault Code: F1767
Message
Failed to get telemetry data from application. Error: [errorMessage]
Explanation
This fault occurs when there is a failure to get telemetry data from the application.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: telemetry-get-data-failed
mibFaultName: fltCommTelemetryTelemetryGetDataFailed
Affected MO: sys/svc-ext/telemetry
fltCommTelemetryTelemetrySendDataFailed
Fault Code: F1768
Message
Failed to send telemetry data. Error: [errorMessage]
Explanation
This fault occurs when there is a failure to send telemetry data.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: telemetry-send-data-failed
mibFaultName: fltCommTelemetryTelemetrySendDataFailed
Affected MO: sys/svc-ext/telemetry
fltAaaUserEpPasswordEncryptionKeyNotSet
Fault Code: F1769
Message
The password encryption key has not been set.
Explanation
This fault typically occurs because a password encryption key is not set on the system. The password encryption key is used for protecting credentials when a user exports the system’s configurations
Recommended Action
If you see this fault, take the following actions:
Step 1 Scope to security, and run the command "set password-encryption-key".
Fault Details
Cause: password-encryption-key-not-set
mibFaultName: fltAaaUserEpPasswordEncryptionKeyNotSet
Affected MO: sys/user-ext
fltSdInternalMgmtBootstrapInternalMgmtVnicConfigFail
Fault Code: F1774
Message
Failed to allocate internal mgmt vnic for application instance [appName]-[identifier] on slot [slotId]
Explanation
This fault occurs when vnic for internal mgmt bootstrap (in decorator case) was not allocated.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: internal-mgmt-vnic-config-fail
mibFaultName: fltSdInternalMgmtBootstrapInternalMgmtVnicConfigFail
moClass: sd:InternalMgmtBootstrap
Affected MO: sys-secsvc/slot-[slotId]/app-inst-[appInstId]/internal-mgmt-bootstrap
fltSdExternalLduLinkExternalLduLinkVnicConfigFail
Fault Code: F1775
Message
Failed to allocate vnic for ExternalLduLink [name] in LogicalDevice [ldName](type:[type]) for [appName] on slot [slotId]
Explanation
This fault occurs when vnic for ExternalLduLink was not allocated.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: external-ldu-link-vnic-config-fail
mibFaultName: fltSdExternalLduLinkExternalLduLinkVnicConfigFail
moClass: sd:ExternalLduLink
Affected MO: sys-secsvc/ld-[name]/ldu-[slotId]/ext-ldulink-[slotId]-[aggrPortId]-[portId]-[appName]
Affected MO: sys-secsvc/slot-[slotId]/app-inst-[appInstId]/ldu-[slotId]/ext-ldulink-[slotId]-[aggrPortId]-[portId]-[appName]
fltSdAppLduLinkAppLduLinkEndpoint1VnicConfigFail
Fault Code: F1776
Message
Failed to allocate vnic for AppLduLink [name] in LogicalDevice [ldName](type:[type]) for [appName] on slot [slotId]
Explanation
This fault occurs when vnics for EndPoint1(decorator) in AppLduLink are not allocated.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: app-ldu-link-endpoint1-vnic-config-fail
mibFaultName: fltSdAppLduLinkAppLduLinkEndpoint1VnicConfigFail
Affected MO: sys-secsvc/ld-[name]/ldu-[slotId]/app-ldulink-[name]-[endpoint1AppInstId]-[endpoint2AppInstId]
Affected MO: sys-secsvc/slot-[slotId]/app-inst-[appInstId]/ldu-[slotId]/app-ldulink-[name]-[endpoint1AppInstId]-[endpoint2AppInstId]
fltSdAppLduLinkAppLduLinkEndpoint2VnicConfigFail
Fault Code: F1777
Message
Failed to allocate vnic for AppLduLink [name] in LogicalDevice [ldName](type:[type]) for main app on slot [slotId]
Explanation
This fault occurs when vnics for EndPoint2(main app) in AppLduLink are not allocated.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: app-ldu-link-endpoint2-vnic-config-fail
mibFaultName: fltSdAppLduLinkAppLduLinkEndpoint2VnicConfigFail
Affected MO: sys-secsvc/ld-[name]/ldu-[slotId]/app-ldulink-[name]-[endpoint1AppInstId]-[endpoint2AppInstId]
Affected MO: sys-secsvc/slot-[slotId]/app-inst-[appInstId]/ldu-[slotId]/app-ldulink-[name]-[endpoint1AppInstId]-[endpoint2AppInstId]
fltSdPreAllocatedVnicVnicPreAllocationFail
Fault Code: F1778
Message
Failed to pre-allocate vnic for application instance [appName]-[identifier] on slot [slotId] (type:[portType])
Explanation
This fault occurs when vnics are not pre-allocated for native/container FTD instances.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: vnic-pre-allocation-fail
mibFaultName: fltSdPreAllocatedVnicVnicPreAllocationFail
moClass: sd:PreAllocatedVnic
Affected MO: sys-secsvc/slot-[slotId]/app-inst-[appInstId]/pre-allocated-vnic-[portType]-[mgmtSubType]
fltSdLogicalDeviceDifferentResourcesInProfile
Fault Code: F1779
Message
[resourceFaultMsg]
Explanation
This fault occurs when app instances of logical device have different resources in resource profile.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: different-resources-in-profile
mibFaultName: fltSdLogicalDeviceDifferentResourcesInProfile
moClass: sd:LogicalDevice
Affected MO: sys-secsvc/ld-[name]
fltFirmwareVersionIssueImageVersionMismatch
Fault Code: F1780
Message
Mismatched [mismatchType] image version [version] detected. Expected version [installedImageVersion] from FXOS [installedPackageVersion].
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: image-version-mismatch
mibFaultName: fltFirmwareVersionIssueImageVersionMismatch
moClass: firmware:VersionIssue
Affected MO: capabilities/ep/mgmt-ext/fw-[deployment]/version-issue
Affected MO: capabilities/fw-[deployment]/version-issue
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/fw-[deployment]/version-issue
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fw-[deployment]/version-issue
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fw-[deployment]/version-issue
Affected MO: sys/chassis-[id]/blade-[slotId]/bios/fw-[deployment]/version-issue
Affected MO: sys/chassis-[id]/blade-[slotId]/board/graphics-card-[id]/fw-[deployment]/version-issue
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/fw-[deployment]/version-issue
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/fw-[deployment]/version-issue
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-flexflash-[id]/fw-[deployment]/version-issue
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fw-[deployment]/version-issue
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/bios/fw-[deployment]/version-issue
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fw-[deployment]/version-issue
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fw-[deployment]/version-issue
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fw-[deployment]/version-issue
Affected MO: sys/chassis-[id]/blade-[slotId]/os-ctrl/fw-[deployment]/version-issue
Affected MO: sys/chassis-[id]/epmfpga-[slot]/fw-[deployment]/version-issue
Affected MO: sys/chassis-[id]/fpga/fw-[deployment]/version-issue
Affected MO: sys/chassis-[id]/rommon/fw-[deployment]/version-issue
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fw-[deployment]/version-issue
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/fw-[deployment]/version-issue
Affected MO: sys/fex-[id]/mgmt/fw-[deployment]/version-issue
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fw-[deployment]/version-issue
Affected MO: sys/mgmt/fw-[deployment]/version-issue
Affected MO: sys/os-ctrl/fw-[deployment]/version-issue
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/fw-[deployment]/version-issue
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fw-[deployment]/version-issue
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fw-[deployment]/version-issue
Affected MO: sys/rack-unit-[id]/bios/fw-[deployment]/version-issue
Affected MO: sys/rack-unit-[id]/board/graphics-card-[id]/fw-[deployment]/version-issue
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/fw-[deployment]/version-issue
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/fw-[deployment]/version-issue
Affected MO: sys/rack-unit-[id]/board/storage-flexflash-[id]/fw-[deployment]/version-issue
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fw-[deployment]/version-issue
Affected MO: sys/rack-unit-[id]/ext-board-[id]/bios/fw-[deployment]/version-issue
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fw-[deployment]/version-issue
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fw-[deployment]/version-issue
Affected MO: sys/rack-unit-[id]/mgmt/fw-[deployment]/version-issue
Affected MO: sys/rack-unit-[id]/os-ctrl/fw-[deployment]/version-issue
Affected MO: sys/switch-[id]/mgmt/fw-[deployment]/version-issue
fltFabricComputeSlotEpBladeDecommissionFail
Fault Code: F1781
Message
Service Module [slotId] - Decommission failed, reason: [failReason]
Explanation
This fault occurs when Cisco FPR Manager failed to decommission the blade.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltFabricComputeSlotEpBladeDecommissionFail
moClass: fabric:ComputeSlotEp
Affected MO: fabric/server/chassis-[chassisId]/slot-[slotId]
fltEtherFtwPortPairPhyBypass
Fault Code: F1782
Message
Port-pair [portName]-[peerPortName] in phy-bypass mode due to watchdog timeout
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltEtherFtwPortPairPhyBypass
moClass: ether:FtwPortPair
Affected MO: sys/switch-[id]/fail-to-wire/ftw-port-[slotId]-[aggrPortId]-[portId]-port-[peerSlotId]-[peerAggrPortId]-[peerPortId]
fltEtherFtwPortPairPhyBypassErr
Fault Code: F1783
Message
Port-pair [portName]-[peerPortName] in phy-bypass mode due to switch config error
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltEtherFtwPortPairPhyBypassErr
moClass: ether:FtwPortPair
Affected MO: sys/switch-[id]/fail-to-wire/ftw-port-[slotId]-[aggrPortId]-[portId]-port-[peerSlotId]-[peerAggrPortId]-[peerPortId]
fltMgmtImporterConfiguration import failed
Fault Code: F1784
Message
Importing configuration failed: [errMsg]
Explanation
This fault occurs if error happens when importing a configuration file
Recommended Action
If you see this fault, please take actions based on the error description.
Fault Details
Cause: config-import-failed
mibFaultName: fltMgmtImporterConfigurationImportFailed
Affected MO: sys/import-config-[hostname]