Troubleshooting Platform and Software Requirements
This chapter includes troubleshooting for platform and software requirements that are associated with Cisco Dynamic Fabric Automation (DFA).
This chapter contains the following sections:
- Troubleshooting Platform and Software Requirements for the Cisco Nexus 6000 Series Switches
- Troubleshooting Platform and Software Requirements for Cisco Nexus 7000 Series Switches
- Troubleshooting Platform and Software Requirements of the Cisco Nexus 1000V Series Switch
- Troubleshooting OpenStack for Cisco Dynamic Fabric Automation
Troubleshooting Platform and Software Requirements for the Cisco Nexus 6000 Series Switches
This section describes troubleshooting procedures for various issues that involve platform and software requirements for Cisco Nexus 6000 Series switches that are associated with a Cisco Dynamic Fabric Automation deployment.
Symptom | Cause | Resolution | ||||
---|---|---|---|---|---|---|
Layer 3 forwarding is not functioning. |
On a Cisco Nexus 6000 Series switch, Layer 3 forwarding does not work without the LAN base license. |
|
||||
The Border Gateway Protocol (BGP) is not functioning. |
On the Cisco Nexus 6000 Series switch, an Enterprise License is required to enable BGP. |
|
||||
Performance Monitoring and Configuration Archive is not functioning on a device. |
A Cisco Prime Data Center Network Manager (DCNM) license is required on each device for Performance Monitoring and Configuration Archive to function. Demo licenses will not work.
|
|
Troubleshooting Platform and Software Requirements for Cisco Nexus 7000 Series Switches
This section describes troubleshooting procedures for various issues that involve platform and software requirements for the Cisco Nexus 7000 Series switches that are associated with a Cisco Dynamic Fabric Automation deployment.
Symptom | Cause | Resolution | ||||
---|---|---|---|---|---|---|
|
A Multiprotocol Label Switching (MPLS) license is not installed. |
Upgrade the Cisco NX-OS software to Release 6.2(6a). This version eliminates the requirement for an MPLS license. |
||||
Performance Monitoring and Configuration Archive is not functioning on a device. |
|
|
Troubleshooting Platform and Software Requirements of the Cisco Nexus 1000V Series Switch
See the following URLs for configuration information about the Cisco Nexus 1000V Series switch for Cisco Dynamic Fabric Automation:
Troubleshooting OpenStack for Cisco Dynamic Fabric Automation