Chassis Components
This section describes the different components of the chassis.
Front View
The front of the Cisco MDS 9396S switch contains LEDs, console and management ports, and 96 2/4/8/10/16 Gbps line rate Fibre Channel ports.
1 |
Serial console port |
6 |
USB port |
2 |
System status LED |
7 |
10/100/1000 Mbps Ethernet management port |
3 |
Power supply LED |
8 |
Fibre Channel ports |
4 |
Fan LED |
9 |
Exhaust grill |
5 |
Exhaust grill |
Rear View
The rear of the Cisco MDS 9396S switch has two PSU bays for the redundant AC PSUs, two fan bays for the redundant fan modules and the chassis ground pad. Each side panel has attachments points for rack mount rails.
1 |
Power receptable |
5 |
Fan module 2 |
2 |
Power supply 1 |
6 |
Power supply 2 |
3 |
Power module handle |
7 |
Fan securing screws |
4 |
Fan module 1 |
1 |
Power supply unit slot 1 |
3 |
Chassis fan module slot 2 |
2 |
Chassis fan module slot 1 |
4 |
Power supply unit slot 2 |
Grounding Point
The rear of the Cisco MDS 9396S switch also contains the grounding point which is present under a label (Figure 2).
1 |
Grounding point |
Switch LEDs
The Cisco MDS 9396S Multilayer Fabric Switch includes the LEDs shown in the following figure. You can use the LEDs to quickly identify the system status.
1 |
System status LED |
4 |
Management port link LED |
2 |
Power subsystem status LED |
5 |
Management port activity LED |
3 |
Fan subsystem status LED |
6 |
FC port link status LED |
1 |
PSU status LED |
2 |
Fan module status LED |
The following table describes the chassis activity LEDs for the Cisco MDS 9396S switch.
Indicator |
Location |
Color |
Status |
State |
---|---|---|---|---|
Power subsystem status LED |
Front panel of chassis |
Off |
Off |
Either of the following conditions exists:
|
Green |
Solid On |
Both PSUs are installed and operating |
||
Red |
Solid On |
A PSU has failed. |
||
Status LED |
Front panel of chassis |
Green |
Solid On |
All diagnostics have passed, NX-OS is running and the system is operational. |
Orange |
Solid On |
Any of the following conditions exists:
|
||
Red |
Blinking |
Unmatched airflow direction for PSU/Fan tray. |
||
Solid On |
Any of the following conditions exists:
|
|||
Fan status |
Front panel of chassis |
Green |
Solid on |
Both fan modules are operational. |
Red |
Solid on |
Fan failure. |
||
PSU Status Indicators |
Faceplate of each PSU |
Green |
Off |
No input to the PSU. |
Solid on |
PSU output is OK. |
|||
Blinking |
PSU output is not OK, but input is OK. |
|||
Amber |
Solid on |
Any of the following conditions exists in the PSU: Over voltage Over current Over temperature Fan failure. |
||
Blinking |
PSU has a fault, but is still operating. |
|||
Off |
PSU is operating normally. |
|||
Fan Status |
Faceplate of each Fan Module |
Green |
Solid on |
Fan module is operating normally. |
Amber |
Solid on |
One fan in the fan module has failed. |
||
Red |
Solid on |
Both fans in the fan module have failed. |