Configuring FCoE VLANs and Virtual Interfaces

This chapter contains the following sections:

Information About Virtual Interfaces

Cisco Nexus devices support Fibre Channel over Ethernet (FCoE), which allows Fibre Channel and Ethernet traffic to be carried on the same physical Ethernet connection between the switch and the servers.

The Fibre Channel portion of FCoE is configured as a virtual Fibre Channel interface. Logical Fibre Channel features (such as interface mode) can be configured on virtual Fibre Channel interfaces.

A virtual Fibre Channel interface must be bound to an interface before it can be used. The binding is to a physical Ethernet interface (when the converged network adapter (CNA) is directly connected to the Cisco Nexus device), a MAC address (when the CNA is remotely connected over a Layer 2 bridge), or an EtherChannel when the CNA connects to the Fibre Channel Forwarder (FCF) over a virtual port channel (vPC).

VE Port

A virtual expansion (VE) port acts as an expansion port in an FCoE network. VE ports can connect multiple FCoE switches together in the network. You can bind a VE port to a physical ethernet port or a port channel.

On the Cisco Nexus 5000 and 6000 Series switches, traffic across members of a port channel that a VE_Port is bound to is load balanced based on SID, DID, and OXID.

In order to enable all links to be used in the port-channel for FCoE traffic, enter the port-channel load-balance ethernet source-dest-port command to configure 'port-channel load balancing' to 'source-dest-port'. The configuration 'source-destination-oxid' load balancing is used for FCoE traffic.

Guidelines and Limitations for FCoE VLANs and Virtual Interfaces

FCoE VLANs and Virtual Fiber Channel (vFC) interfaces have these guidelines and limitations:

  • Each vFC interface must be bound to an FCoE-enabled Ethernet or EtherChannel interface or to the MAC address of a remotely connected adapter. FCoE is supported on 10-Gigabit Ethernet interfaces.

    The Ethernet or EtherChannel interface that you bind to the vFC interface must be configured as follows:

    • The Ethernet or EtherChannel interface must be a trunk port (use the switchport mode trunk command).

    • The FCoE VLAN that corresponds to a vFC’s VSAN must be in the allowed VLAN list.

    • You must not configure an FCoE VLAN as the native VLAN of the trunk port.


      Note


      The native VLAN is the default VLAN on a trunk. Any untagged frames transit the trunk as native VLAN traffic.


    • You should use an FCoE VLAN only for FCoE.

    • Do not use the default VLAN, VLAN1, as an FCoE VLAN.

    • You must configure the Ethernet interface as PortFast (use the spanning-tree port type edge trunk command).


      Note


      You are not required to configure trunking on the server interface even if the switch interface is configured with trunking enabled. All non-FCoE traffic from the server is passed on the native VLAN.


  • The vFC interface can be bound to Ethernet port channels with multiple member ports connected to FCoE Initialization Protocol (FIP) snooping bridges.

  • Each vFC interface is associated with only one VSAN.

  • You must map any VSAN with associated vFC interfaces to a dedicated FCoE-enabled VLAN.

  • FCoE is not supported on private VLANs.

  • If the converged access switches (in the same SAN fabric or in another) need to be connected to each other over Ethernet links for a LAN alternate path, then you must explicitly configure such links to exclude all FCoE VLANs from membership.

  • You must use separate FCoE VLANs for FCoE in SAN-A and SAN-B fabrics.

  • FCoE connectivity to pre-FIP CNAs over virtual port channels (vPCs) is not supported.

  • The maximum number of vFCs that can be bound to a port-channel is 48.


Note


Virtual interfaces are created with the administrative state set to down. You must explicitly configure the administrative state to bring the virtual interface into operation.


Configuring Virtual Interfaces

Mapping a VSAN to a VLAN

A unique, dedicated VLAN must be configured at every converged access switch to carry traffic for each VSAN in the SAN (for example, VLAN 1002 for VSAN 1, VLAN 1003 for VSAN 2, and so on). If Multiple Spanning Tree (MST) is enabled, a separate MST instance must be used for FCoE VLANs.

SUMMARY STEPS

    1.    switch# configure terminal

    2.    switch(config)# vlan vlan-id

    3.    switch(config-vlan)# fcoe [vsan vsan-id]

    4.    switch(config-vlan)# exit

    5.    (Optional) switch(config-vlan)# show vlan fcoe

    6.    (Optional) switch(config-if)# copy running-config startup-config


DETAILED STEPS
     Command or ActionPurpose
    Step 1 switch# configure terminal
     

    Enters global configuration mode.

     
    Step 2 switch(config)# vlan vlan-id
     

    Enters VLAN configuration mode. The VLAN number range is from 1 to 4096.

     
    Step 3 switch(config-vlan)# fcoe [vsan vsan-id]
     

    Enables FCoE for the specified VLAN. If you do not specify a VSAN number, a mapping is created from this VLAN to the VSAN with the same number.

    Configures the mapping from this VLAN to the specified VSAN.

     
    Step 4 switch(config-vlan)# exit
     

    Exits VLAN configuration mode. You must exit this mode to execute the configured commands on your Cisco Nexus device.

     
    Step 5 switch(config-vlan)# show vlan fcoe
     
    (Optional)

    Displays information about the FCoE configuration for a VLAN.

     
    Step 6switch(config-if)# copy running-config startup-config   (Optional)

    Saves the change persistently through reboots and restarts by copying the running configuration to the startup configuration.

     

    This example shows how to map VLAN 200 to VSAN 2:

    switch(config)# vlan 200
    switch(config-vlan)# fcoe vsan 2

    Creating a Virtual Fibre Channel Interface

    You can create a virtual Fibre Channel interface. You must bind the virtual Fibre Channel interface to a physical interface before it can be used.

    SUMMARY STEPS

      1.    switch# configure terminal

      2.    switch(config)# interface vfc vfc-id

      3.    switch(config-if)# bind {interface {ethernet slot/port | port-channel channel-number} | mac-address MAC-address}

      4.    (Optional) switch(config-if)# no bind {interface {ethernet slot/port | port-channel channel-number} | mac-address MAC-address}

      5.    (Optional) switch(config)# no interface vfc vfc-id


    DETAILED STEPS
       Command or ActionPurpose
      Step 1switch# configure terminal  

      Enters global configuration mode.

       
      Step 2 switch(config)# interface vfc vfc-id
       

      Creates a virtual Fibre Channel interface (if it does not already exist) and enters interface configuration mode.

      The virtual Fibre Channel interface ID range is from 1 to 8192.

       
      Step 3 switch(config-if)# bind {interface {ethernet slot/port | port-channel channel-number} | mac-address MAC-address}
       

      Binds the virtual Fibre Channel interface to the specified interface.

       
      Step 4 switch(config-if)# no bind {interface {ethernet slot/port | port-channel channel-number} | mac-address MAC-address}
       
      (Optional)

      Unbinds the virtual Fibre Channel interface from the specified interface.

       
      Step 5 switch(config)# no interface vfc vfc-id
       
      (Optional)

      Deletes a virtual Fibre Channel interface.

       

      This example shows how to bind a virtual Fibre Channel interface to an Ethernet interface:

      switch# configure terminal
      switch(config)# interface vfc 4
      switch(config-if)# bind interface ethernet 1/4
      
      

      This example shows how to bind a virtual Fibre Channel interface to a Cisco Nexus 2232PP Fabric Extender (FEX) Ethernet interface:

      switch# configure terminal
      switch(config)# interface vfc 1001
      switch(config-if)# bind interface ethernet 100/1/1
      
      

      This example shows how to bind a virtual Fibre Channel interface to create a vPC:

      switch# configure terminal
      switch(config)# interface vfc 3
      switch(config-if)# bind interface port-channel 1
      
      

      This example shows how to bind a virtual Fibre Channel interface on a Cisco Nexus 2232PP FEX to create a vPC:

      switch# configure terminal
      switch(config)# interface vfc 1001
      switch(config-if)# bind interface ethernet 100/1/1
      
      

      Note


      An error message is displayed if you attempt to bind the interface to a Cisco Nexus FEX that does not support FCoE.


      This example shows how to bind a virtual Fibre Channel interface to a MAC address:

      switch# configure terminal
      switch(config)# interface vfc 2
      switch(config-if)# bind mac-address 00:0a:00:00:00:36
      
      

      This example shows how to bind a virtual Fibre Channel interface to a Cisco Nexus 2232PP FEX MAC address:

      switch# configure terminal
      switch(config)# interface vfc 1001
      switch(config-if)# bind mac-address 00:01:0b:00:00:02
      
      

      This example shows how to delete a virtual Fibre Channel interface:

      switch# configure terminal
      switch(config)# no interface vfc 4
      

      Configuring vFC Interface

      The following steps show how to configure vPC interface to a member port of a multi-member port-channel.

      Note


      You can un-configure a 4-port vPC only after removing member ports from port-channel. You can un-configure only on a single member port-channel.


      SUMMARY STEPS

        1.    Create a multi-member port-channel.

        2.    Add individual member port to a multi-member port-channel.

        3.    Associate vPC to a member port of a multi-member port-channel.


      DETAILED STEPS
        Step 1   Create a multi-member port-channel.
        switch(config-vlan)#  interface port-channel 500
        switch(config-vlan)# [no]fcoe multi-vfc
        Step 2   Add individual member port to a multi-member port-channel.
        switch(config-vlan)# interface ethernet 100/1/1
        switch(config-vlan)# channel-group 500
        switch (config)# interface ethernet 100/1/2
        switch(config-if)# channel-group 500
        Step 3   Associate vPC to a member port of a multi-member port-channel.
        switch(config)#  interface vfc 10011
        switch(config-vlan)# bind interface ethernet 100/1/1
        switch(config-vlan)#  interface vfc 10012
        switch (config)#  bind interface ethernet 100/1/2

        Associating a Virtual Fibre Channel Interface to a VSAN

        A unique, dedicated VLAN must be configured at every converged access switch to carry traffic for each Virtual Fabric (VSAN) in the SAN (for example, VLAN 1002 for VSAN 1, VLAN 1003 for VSAN 2, and so on). If MST is enabled, a separate MST instance must be used for FCoE VLANs.

        SUMMARY STEPS

          1.    switch# configure terminal

          2.    switch(config)# vsan database

          3.    switch(config-vsan)# vsan vsan-id interface vfc vfc-id

          4.    (Optional) switch(config-vsan)# no vsan vsan-id interface vfc vfc-id


        DETAILED STEPS
           Command or ActionPurpose
          Step 1switch# configure terminal  

          Enters global configuration mode.

           
          Step 2switch(config)# vsan database
           

          Enters VSAN configuration mode.

           
          Step 3switch(config-vsan)# vsan vsan-id interface vfc vfc-id
           

          Configures the association between the VSAN and virtual Fibre Channel interface.

          The VSAN number must map to a VLAN on the physical Ethernet interface that is bound to the virtual Fibre Channel interface.

           
          Step 4switch(config-vsan)# no vsan vsan-id interface vfc vfc-id
           
          (Optional)

          Disassociates the connection between the VSAN and virtual Fibre Channel interface.

           

          This example shows how to associate a virtual Fibre Channel interface to a VSAN:

          switch# configure terminal
          switch(config)# vsan database
          switch(config-vsan)# vsan 2 interface vfc 4

          Creating an Implicit Virtual Fibre Channel Port Channel Interface

          You can create a virtual Fibre Channel (vFC), and implicitly bind it to an Ethernet interface or a port-channel using a single command. For this, the vFC identifier must match the Ethernet interface or port-channel identifier. The Ethernet interface can be a module (slot or port) or a Fabric Extender (FEX) interface (chassis, slot or port).

          Note


          You cannot create an implicit vFC in a breakout port.


          Configuring virtual Fibre Channel Interface
          Before You Begin
          • Ensure you have installed the correct license for FCoE.

          • Ensure you have enabled FCoE.


            Step 1   Enter global configuration mode:

            switch# configure terminal

            Step 2   Create a VFC (if it does not already exist):

            Additionally, vfc slot/port binds the vFC to an Ethernet slot/port interface. vfc chassis/slot/port binds the vFC to a FEX interface.

            switch(config) # interface vfc {id | slot/port | chassis/slot/port

            Step 3   Bring up the vFC interface:

            switch(config-if) # no shutdown

            Step 4   Exit the interface configuration mode:

            switch(config-if) # exit


            Configuring virtual Fibre Channel Interface

            This example shows how to implicitly bind a virtual Fibre Channel interface to an Ethernet interface:

            switch# configure terminal
            switch(config)# interface vfc 101/1/1
            switch(config-if)# no shutdown
            .
            .
            .
            .
            Switch# show interface vfc 101/1/1
                vfc101/1/1 is trunking
                Bound interface is Ethernet101/1/1
                Hardware is Ethernet 
                Port WWN is 20:00:00:2a:6a:15:d2:7b
                Admin port mode is F, trunk mode is on
                snmp link state traps are enabled
                Port mode is TF
                Port vsan is 600
                Trunk vsans (admin allowed and active) (1,500,600)
                Trunk vsans (up)                       (600)
                Trunk vsans (isolated)                 ()
                Trunk vsans (initializing)             (1,500)
                1 minute input rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
                1 minute output rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
                  49 frames input, 5516 bytes
                    0 discards, 0 errors
                  49 frames output, 5772 bytes
                    0 discards, 0 errors
                last clearing of "show interface" counters Fri Oct 30 06:19:33 2015
                Interface last changed at Fri Oct 30 06:19:33 2015
            
            

            Configuring virtual Fibre Channel – Port Channel Interface


              Step 1   Enter global configuration mode:

              switch# configure terminal

              Step 2   Create a vFC that implicitly binds to the Ethernet port-channel based on its number:

              The port number range is from 257 to 4096.

              switch(config) # interface vfc-port-channel port number

              Step 3   Bring up the vFC port:

              switch(config-if) # no shutdown

              Step 4   Exit from the current interface configuration mode:

              switch(config-if) # exit


              Configuring virtual Fibre Channel - Port Channel Interface

              The example shows how you can create a vFC-port-channel that implicitly binds to Ethernet port-channel:

              switch# configure terminal
              switch(config)# interface vfc-port-channel 300
              switch(config-if)# no shutdown
              .
              .
              .
              .
              switch# show interface vfc-port-channel 258
              
                  vfc-po258 is trunking
                  Bound interface is port-channel258
                  Hardware is Ethernet 
                  Port WWN is 21:01:8c:60:4f:59:31:3f
                  Admin port mode is E, trunk mode is on
                  snmp link state traps are enabled
                  Port mode is TE
                  Port vsan is 600
                  Trunk vsans (admin allowed and active) (1,100,500,600)
                  Trunk vsans (up)                       (600)
                  Trunk vsans (isolated)                 ()
                  Trunk vsans (initializing)             (1,100,500)
                  1 minute input rate 3448 bits/sec, 431 bytes/sec, 4 frames/sec
                  1 minute output rate 9064 bits/sec, 1133 bytes/sec, 4 frames/sec
                    977735 frames input, 77172556 bytes
                      0 discards, 0 errors
                    977733 frames output, 205924892 bytes
                      0 discards, 0 errors
                  last clearing of "show interface" counters Thu Oct 29 06:35:41 2015
                  Interface last changed at Thu Oct 29 06:35:41 2015
              
              

              Verifying the Virtual Interface

              To display configuration information about virtual interfaces, perform one of the following tasks:

              Command

              Purpose

              switch# show interface vfc vfc-id

              Displays the detailed configuration of the specified Fibre Channel interface.

              switch# show interface brief

              Displays the status of all interfaces.

              switch# show vlan fcoe

              Displays the mapping of FCoE VLANs to VSANs.

              This example shows how to display a virtual Fibre Channel interface bound to an Ethernet interface:

              switch# show interface vfc 3
              vfc3 is up
                  Bound interface is Ethernet1/37
                  Hardware is Virtual Fibre Channel
                  Port WWN is 20:02:00:0d:ec:6d:95:3f
                  Admin port mode is F, trunk mode is on
                  snmp link state traps are enabled
                  Port mode is F, FCID is 0x490100
                  Port vsan is 931
                  1 minute input rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
                  1 minute output rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
                    0 frames input, 0 bytes
                      0 discards, 0 errors
                    0 frames output, 0 bytes
                      0 discards, 0 errors
                  Interface last changed at Thu May 21 04:44:42 2009

              This example shows how to display a virtual Fibre Channel interface bound to a MAC address:

              switch# show interface vfc 1001
              vfc1001 is down
                  Bound MAC is 00:0a:00:00:00:01
                  Hardware is Virtual Fibre Channel
                  Port WWN is 23:e8:00:0d:ec:6d:95:3f
                  Admin port mode is F, trunk mode is on
                  snmp link state traps are enabled
                  Port vsan is 901
                  1 minute input rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
                  1 minute output rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
                    0 frames input, 0 bytes
                      0 discards, 0 errors
                    0 frames output, 0 bytes
                      0 discards, 0 errors

              This example shows how to display the status of all the interfaces on the switch (some output has been removed for brevity):

              switch# show interface brief
              -------------------------------------------------------------------------------
              Interface  Vsan   Admin  Admin   Status          SFP    Oper  Oper   Port
                                Mode   Trunk                          Mode  Speed  Channel
                                       Mode                                 (Gbps)
              -------------------------------------------------------------------------------
              fc3/1      1      auto   on      trunking         swl    TE      2    --
              fc3/2      1      auto   on      sfpAbsent        --     --           --
              ...
              fc3/8      1      auto   on      sfpAbsent        --     --           --
              -------------------------------------------------------------------------------
              Interface                Status     IP Address        Speed    MTU   Port
                                                                                   Channel
              -------------------------------------------------------------------------------
              Ethernet1/1              hwFailure  --                --       1500  --
              Ethernet1/2              hwFailure  --                --       1500  --
              Ethernet1/3              up         --                10000    1500  --
              ...
              Ethernet1/39             sfpIsAbsen --                --       1500  --
              Ethernet1/40             sfpIsAbsen --                --       1500  --
              -------------------------------------------------------------------------------
              Interface                Status     IP Address        Speed    MTU
              -------------------------------------------------------------------------------
              mgmt0                    up         172.16.24.41      100      1500
              -------------------------------------------------------------------------------
               
              -------------------------------------------------------------------------------
              Interface  Vsan   Admin  Admin   Status          SFP    Oper  Oper   Port
                                Mode   Trunk                          Mode  Speed  Channel
                                       Mode                                 (Gbps)
              -------------------------------------------------------------------------------
              vfc 1        1      F      --      down             --     --           --
              ...
               

              This example shows how to display the mapping between the VLANs and VSANs on the switch:

              switch# show vlan fcoe
              VLAN      VSAN      Status
              --------  --------  --------
              15        15        Operational
              20        20        Operational
              25        25        Operational
              30        30        Non-operational

              Mapping VSANs to VLANs Example Configuration

              The following example shows how to configure the FCoE VLAN and a virtual Fibre Channel interface:

              SUMMARY STEPS

                1.    Enable the associated VLAN and map the VLAN to a VSAN.

                2.    Configure the VLAN on a physical Ethernet interface.

                3.    Create a virtual Fibre Channel interface and bind it to a physical Ethernet interface.

                4.    Associate the virtual Fibre Channel interface to the VSAN.

                5.    (Optional) Display membership information for the VSAN.

                6.    (Optional) Display the interface information for the virtual Fibre Channel interface.


              DETAILED STEPS
                Step 1   Enable the associated VLAN and map the VLAN to a VSAN.
                switch(config)# vlan 200
                switch(config-vlan)# fcoe vsan 2
                switch(config-vlan)# exit
                 
                Step 2   Configure the VLAN on a physical Ethernet interface.
                switch# configure terminal
                switch(config)# interface ethernet 1/4
                switch(config-if)# spanning-tree port type edge trunk
                switch(config-if)# switchport mode trunk
                switch(config-if)# switchport trunk allowed vlan 1,200
                switch(config-if)# exit
                Step 3   Create a virtual Fibre Channel interface and bind it to a physical Ethernet interface.
                switch(config)# interface vfc 4
                switch(config-if)# bind interface ethernet 1/4
                switch(config-if)# exit
                
                
                Note   

                By default, all virtual Fibre Channel interfaces reside on VSAN 1. If the VLAN to VSAN mapping is to a VSAN other than VSAN 1, then proceed to Step 4.

                Step 4   Associate the virtual Fibre Channel interface to the VSAN.
                switch(config)# vsan database
                switch(config-vsan)# vsan 2 interface vfc 4
                switch(config-vsan)# exit
                
                
                Step 5   (Optional) Display membership information for the VSAN.
                switch# show vsan 2 membership
                vsan 2 interfaces
                           vfc 4
                
                
                Step 6   (Optional) Display the interface information for the virtual Fibre Channel interface.
                switch# show interface vfc 4
                
                vfc4 is up
                Bound interface is Ethernet1/4
                Hardware is Virtual Fibre Channel
                Port WWN is 20:02:00:0d:ec:6d:95:3f 
                Port WWN is 20:02:00:0d:ec:6d:95:3f 
                snmp link state traps are enabled
                Port WWN is 20:02:00:0d:ec:6d:95:3f 
                APort WWN is 20:02:00:0d:ec:6d:95:3f
                snmp link state traps are enabled
                Port mode is F, FCID is 0x490100
                Port vsan is 931
                1 minute input rate 0 bits/sec, 0 bytes/sec, 0 frames/sec 
                1 minute output rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
                0 frames input, 0 bytes 0 discards, 0 errors 
                0 frames output, 0 bytes 0 discards, 0 errors
                Interface last changed at Thu Mar 11 04:44:42 2010
                
                

                FCoE over Enhanced vPC

                Although Ethernet traffic is dual homed between a FEX and a switch pair in an enhanced vPC topology, FCoE traffic must be single-homed to maintain SAN isolation. Therefore, while enhanced vPC supports FCoE, a single homed FEX topology can be a better choice when SAN isolation and high FCoE bandwidth are required.

                Consider the following disadvantages of enhanced vPC for a single-homed topology:

                • A typical SAN network maintains two fabrics, SAN A and SAN B, with traffic isolated between the two. In an enhanced vPC topology, each switch must be paired (single homed) with a FEX to ensure that FCoE traffic from one FEX is sent to only one switch, while Ethernet traffic is dual homed between each FEX and both switches. Because FCoE traffic from the FEX flows to only one switch while Ethernet traffic flows to both, the traffic load for the FEX uplinks is not evenly balanced.

                • In a FEX with eight uplink ports, Ethernet traffic can use all eight ports, while the single-homed FCoE traffic is limited by this topology to using only four of those ports, restricting the maximum bandwidth available for FCoE. As a further restriction, the default QoS template for the shared link allocates only half the link bandwidth to FCoE traffic, with the other half allocated to Ethernet traffic.

                • In an enhanced vPC topology with FCoE, the host vPC is limited to two ports, one to each FEX.

                The following figure shows the FCoE traffic flow in a system with two Cisco Nexus 2000 FEXs, each associated with a different Cisco Nexus device.

                Figure 1. FCoE over Enhanced vPC



                Configuring FCoE over Enhanced vPC

                FCoE traffic must be single homed to maintain SAN isolation. You must first associate a FEX with only one switch. When the FEX and switch are associated, you can then create a virtual Fibre Channel (vFC) interface and bind it to a port.

                After pairing the FEX and switch on the first peer, you repeat the configuration on the second peer using a different port number to ensure SAN traffic isolation. The different configuration will not cause a consistency error because the FCoE portion of the enhanced vPC configuration is not subject to the vPC consistency check.

                Before You Begin

                Review the limitations in FCoE over Enhanced vPC.

                SUMMARY STEPS

                  1.    switch# configure terminal

                  2.    switch(config) # fex fex-chassis_ID

                  3.    switch(config-fex) # fcoe

                  4.    switch(config-fex) # interface vfc vfc-id

                  5.    switch(config-if) # bind interface ethernet [fex-chassis-ID/]slot/port

                  6.    switch(config-if) # no shutdown

                  7.    (Optional) switch(config-if) # end

                  8.    (Optional) switch(config)# copy running-config startup-config


                DETAILED STEPS
                   Command or ActionPurpose
                  Step 1switch# configure terminal  

                  Enters global configuration mode.

                   
                  Step 2switch(config) # fex fex-chassis_ID  

                  Enters configuration mode for the specified FEX.

                  The range for fex-chassis_ID is from 100 to 199.

                   
                  Step 3switch(config-fex) # fcoe  

                  Configures the FEX to send FCoE traffic only to this switch.

                   
                  Step 4switch(config-fex) # interface vfc vfc-id  

                  Enters configuration mode for the virtual Fibre Channel interface. If the interface does not already exist, this command also creates that interface.

                  The range of vfc-id is from 1 to 8192.

                   
                  Step 5switch(config-if) # bind interface ethernet [fex-chassis-ID/]slot/port  

                  Binds the vFC interface to the specified physical Ethernet interface.

                  The range for fex-chassis_ID is from 100 to 199. The slot must be 1.For FCoE, the range for port is from 1 to 32.

                   
                  Step 6switch(config-if) # no shutdown  

                  Returns the interface to its default operational state.

                   
                  Step 7switch(config-if) # end   (Optional)

                  Return to privileged EXEC mode.

                   
                  Step 8switch(config)# copy running-config startup-config   (Optional)

                  Saves the change persistently through reboots and restarts by copying the running configuration to the startup configuration.

                   

                  This example shows how to pair each FEX to a switch for FCoE traffic:

                  nexus5000-sanA# configure terminal
                  nexus5000-sanA(config) # fex 101
                  nexus5000-sanA(config-fex) # fcoe
                  nexus5000-sanA(config-fex) # interface vfc 1
                  nexus5000-sanA(config-if) # bind interface ethernet 101/1/1
                  nexus5000-sanA(config-if) # no shutdown
                  nexus5000-sanA(config-if) # end
                  nexus5000-sanA# copy running-config startup-config
                  nexus5000-sanA#
                  
                  nexus5000-sanB# configure terminal
                  nexus5000-sanB(config) # fex 102
                  nexus5000-sanB(config-fex) # fcoe
                  nexus5000-sanB(config-fex) # interface vfc 1
                  nexus5000-sanB(config-if) # bind interface ethernet 102/1/1
                  nexus5000-sanB(config-if) # no shutdown
                  nexus5000-sanB(config-if) # end
                  nexus5000-sanB# copy running-config startup-config
                  nexus5000-sanB#
                  
                  

                  SAN Boot with vPC

                  A Cisco Nexus Series switch can use SAN boot if the following conditions are met:

                  • The FEX that contains the port assigned to the vPC must be associated with the Cisco Nexus switch.

                  • Only one VFC interface is bound to a vPC member. You cannot bind multiple interfaces to multiple members.


                  Note


                  If you want to ensure backward compatibility for all previous configurations and supported topologies, you must configure the FEX in a straight-through FEX topology that does not use Enhanced vPC.


                  SAN Boot with vPC Configuration Example

                  In this example, virtual Fibre Channel interface 1 is bound to physical Ethernet interface 101/1/1 on Fabric A and on interface 102/1/1 on Fabric B. The interface is also associated with virtual port channel 1 on both fabrics.

                  nexus5000-sanA(config) # interface vfc 1
                  nexus5000-sanA(config-if) # bind interface eth 101/1/1
                  nexus5000-sanA(config) # interface eth 101/1/1
                  nexus5000-sanA(config-if) # channel-group 1 mode active
                  nexus5000-sanA(config-if) # interface port-channel 1
                  nexus5000-sanA(config-if) # vpc 1
                  nexus5000-sanA(config-if) #
                  
                  nexus5000-sanB(config) # interface vfc 1
                  nexus5000-sanB(config-if) # bind interface eth 102/1/1
                  nexus5000-sanB(config) # interface eth 102/1/1
                  nexus5000-sanB(config-if) # channel-group 1 mode active
                  nexus5000-sanB(config-if) # interface port-channel 1
                  nexus5000-sanB(config-if) # vpc 1