- Preface
- New and Changed Information
- Overview
- Configuring Ethernet Interfaces
- Configuring VLANs
- Configuring Private VLANs
- Configuring Access and Trunk Interfaces
- Configuring EtherChannels
- Configuring Virtual Port Channels
- Configuring Rapid PVST+
- Configuring Multiple Spanning Tree
- Configuring STP Extensions
- Configuring LLDP
- Configuring the MAC Address Table
- Configuring IGMP Snooping
- Configuring Traffic Storm Control
- Configuring the Fabric Extender
- Index
- Information About Ethernet Interfaces
- About the Interface Command
- About Interface Speed
- About the Cisco Discovery Protocol
- About the Error-Disabled State
- About the Debounce Timer Parameters
- About MTU Configuration
- Configuring the UDLD Mode
- Configuring Interface Speed
- Enabling the Error-Disabled Detection
- Enabling the Error-Disabled Recovery
- Configuring the Error-Disabled Recovery Interval
- Configuring the Debounce Timer
- Configuring the Description Parameter
- Disabling and Restarting Ethernet Interfaces
- Displaying Interface Information
Configuring Ethernet Interfaces
This section describes the configuration of the Ethernet interfaces on a Cisco Nexus 5000 Series switch. It contains the following sections:
- Information About Ethernet Interfaces
- Displaying Interface Information
- About the Interface Command
- About Interface Speed
- About the Cisco Discovery Protocol
- About the Error-Disabled State
- About the Debounce Timer Parameters
- About MTU Configuration
- Configuring the UDLD Mode
- Configuring Interface Speed
- Enabling the Error-Disabled Detection
- Enabling the Error-Disabled Recovery
- Configuring the Error-Disabled Recovery Interval
- Configuring the Debounce Timer
- Configuring the Description Parameter
- Disabling and Restarting Ethernet Interfaces
- Default Physical Ethernet Settings
Information About Ethernet Interfaces
The Ethernet ports can operate as standard Ethernet interfaces connected to servers or to a LAN.
The Ethernet interfaces also support Fibre Channel over Ethernet (FCoE). FCoE allows the physical Ethernet link to carry both Ethernet and Fibre Channel traffic.
On a Cisco Nexus 5000 Series switch, the Ethernet interfaces are enabled by default.
- About the Interface Command
- About Interface Speed
- About the Cisco Discovery Protocol
- About the Error-Disabled State
- About the Debounce Timer Parameters
- About MTU Configuration
- UDLD Overview
- Default UDLD Configuration
- UDLD Aggressive and Nonaggressive Modes
- Default CDP Configuration
About the Interface Command
You can enable the various capabilities of the Ethernet interfaces on a per-interface basis using the interface command. When you enter the interface command, you specify the following information:
The interface numbering convention is extended to support use with a Cisco Nexus 2000 Series Fabric Extender as follows:
switch(config)# interface ethernet [chassis/]slot/port
About the Unidirectional Link Detection Parameter
UDLD Overview
The Cisco-proprietary Unidirectional Link Detection (UDLD) protocol allows ports that are connected through fiber optics or copper (for example, Category 5 cabling) Ethernet cables to monitor the physical configuration of the cables and detect when a unidirectional link exists. When the switch detects a unidirectional link, UDLD shuts down the affected LAN port and alerts the user. Unidirectional links can cause a variety of problems, including spanning tree topology loops.
UDLD is a Layer 2 protocol that works with the Layer 1 protocols to determine the physical status of a link. At Layer 1, autonegotiation takes care of physical signaling and fault detection. UDLD performs tasks that autonegotiation cannot perform, such as detecting the identities of neighbors and shutting down misconnected LAN ports. When you enable both autonegotiation and UDLD, Layer 1 and Layer 2 detections work together to prevent physical and logical unidirectional connections and the malfunctioning of other protocols.
A unidirectional link occurs whenever traffic transmitted by the local device over a link is received by the neighbor but traffic transmitted from the neighbor is not received by the local device. If one of the fiber strands in a pair is disconnected, as long as autonegotiation is active, the link does not stay up. In this case, the logical link is undetermined, and UDLD does not take any action. If both fibers are working normally at Layer 1, then UDLD at Layer 2 determines whether those fibers are connected correctly and whether traffic is flowing bidirectionally between the correct neighbors. This check cannot be performed by autonegotiation, because autonegotiation operates at Layer 1.
A Cisco Nexus 5000 Series switch periodically transmits UDLD frames to neighbor devices on LAN ports with UDLD enabled. If the frames are echoed back within a specific time frame and they lack a specific acknowledgment (echo), the link is flagged as unidirectional and the LAN port is shut down. Devices on both ends of the link must support UDLD in order for the protocol to successfully identify and disable unidirectional links.
Note |
By default, UDLD is locally disabled on copper LAN ports to avoid sending unnecessary control traffic on this type of media. |
The following figure shows an example of a unidirectional link condition. Device B successfully receives traffic from Device A on the port. However, Device A does not receive traffic from Device B on the same port. UDLD detects the problem and disables the port.
Default UDLD Configuration
The following table shows the default UDLD configuration.
Feature |
Default Value |
---|---|
UDLD global enable state |
Globally disabled |
UDLD aggressive mode |
Disabled |
UDLD per-port enable state for fiber-optic media |
Enabled on all Ethernet fiber-optic LAN ports |
UDLD per-port enable state for twisted-pair (copper) media |
Disabled on all Ethernet 10/100 and 1000BASE-TX LAN ports |
UDLD Aggressive and Nonaggressive Modes
UDLD aggressive mode is disabled by default. You can configure UDLD aggressive mode only on point-to-point links between network devices that support UDLD aggressive mode. If UDLD aggressive mode is enabled, when a port on a bidirectional link that has a UDLD neighbor relationship established stops receiving UDLD frames, UDLD tries to reestablish the connection with the neighbor. After eight failed retries, the port is disabled.
To prevent spanning tree loops, nonaggressive UDLD with the default interval of 15 seconds is fast enough to shut down a unidirectional link before a blocking port transitions to the forwarding state (with default spanning tree parameters).
When you enable the UDLD aggressive mode, the following occurs:
-
One side of a link has a port stuck (both transmission and receive)
-
One side of a link remains up while the other side of the link is down
In these cases, the UDLD aggressive mode disables one of the ports on the link, which prevents traffic from being discarded.
About Interface Speed
A Cisco Nexus 5000 Series switch has a number of fixed 10-Gigabit ports, each equipped with SFP+ interface adapters. The Cisco Nexus 5010 switch has 20 fixed ports, the first 8 of which are switchable 1-Gigabit and 10-Gigabit ports. The Cisco Nexus 5020 switch has 40 fixed ports, the first 16 of which are switchable 1-Gigabit and 10-Gigabit ports.
About the Cisco Discovery Protocol
The Cisco Discovery Protocol (CDP) is a device discovery protocol that runs over Layer 2 (the data link layer) on all Cisco-manufactured devices (routers, bridges, access servers, and switches) and allows network management applications to discover Cisco devices that are neighbors of already known devices. With CDP, network management applications can learn the device type and the Simple Network Management Protocol (SNMP) agent address of neighboring devices running lower-layer, transparent protocols. This feature enables applications to send SNMP queries to neighboring devices.
CDP runs on all media that support Subnetwork Access Protocol (SNAP). Because CDP runs over the data-link layer only, two systems that support different network-layer protocols can learn about each other.
Each CDP-configured device sends periodic messages to a multicast address, advertising at least one address at which it can receive SNMP messages. The advertisements also contain time-to-live, or holdtime information, which is the length of time a receiving device holds CDP information before discarding it. Each device also listens to the messages sent by other devices to learn about neighboring devices.
The switch supports both CDP Version 1 and Version 2.
Default CDP Configuration
The following table shows the default CDP configuration.
Feature |
Default Setting |
---|---|
CDP interface state |
Enabled |
CDP timer (packet update frequency) |
60 seconds |
CDP holdtime (before discarding) |
180 seconds |
CDP Version-2 advertisements |
Enabled |
About the Error-Disabled State
An interface is in the error-disabled (err-disabled) state when the inteface is enabled administratively (using the no shutdown command) but disabled at runtime by any process. For example, if UDLD detects a unidirectional link, the interface is shut down at runtime. However, because the interface is administratively enabled, the interface status displays as err-disabled. Once an interface goes into the err-disabled state, you must manually reenable it or you can configure an automatic timeout recovery value. The err-disabled detection is enabled by default for all causes. The automatic recovery is not configured by default.
When an interface is in the err-disabled state, use the errdisable detect cause command to find information about the error.
You can configure the automatic err-disabled recovery timeout for a particular err-disabled cause by changing the time variable.
The errdisable recovery cause command provides automatic recovery after 300 seconds. To change the recovery period, use the errdisable recovery interval command to specify the timeout period. You can specify 30 to 65535 seconds.
If you do not enable the err-disabled recovery for the cause, the interface stays in the err-disabled state until you enter the shutdown and no shutdown commands. If the recovery is enabled for a cause, the interface is brought out of the err-disabled state and allowed to retry operation once all the causes have timed out. Use the show interface status err-disabled command to display the reason behind the error.
About the Debounce Timer Parameters
The port debounce time is the amount of time that an interface waits to notify the supervisor of a link going down. During this time, the interface waits to see if the link comes back up. The wait period is a time when traffic is stopped.
You can enable the debounce timer for each interface and specify the delay time in milliseconds.
Caution |
When you enable the port debounce timer the link up and link down detections are delayed, resulting in a loss of traffic during the debounce period. This situation might affect the convergence and reconvergence of some protocols. |
About MTU Configuration
The Cisco Nexus 5000 Series switch is a Layer 2 device. This means it does not fragment frames. As a result, the switch cannot have two ports in the same Layer 2 domain with different maximum transmission units (MTUs). A per-physical Ethernet interface MTU is not supported. Instead, the MTU is set according to the QoS classes. You modify the MTU by setting Class and Policy maps.
Note |
When you show the interface settings, a default MTU of 1500 is displayed for physical Ethernet interfaces and a receive data field size of 2112 is displayed for Fibre Channel interfaces. |
Configuring Ethernet Interfaces
Configuring the UDLD Mode
You can configure normal or aggressive unidirectional link detection (UDLD) modes for Ethernet interfaces on devices configured to run UDLD. Before you can enable a UDLD mode for an interface, you must make sure that UDLD is already enabled on the device that includes the interface. UDLD must also be enabled on the other linked interface and its device.
To use the normal UDLD mode, you must configure one of the ports for normal mode and configure the other port for the normal or aggressive mode. To use the aggressive UDLD mode, you must configure both ports for the aggressive mode.
Note |
Before you begin, UDLD must be enabled for the other linked port and its device. |
To configure the UDLD mode, perform this task:
2.
switch(config)# feature udld
3.
switch(config)# no feature udld
4.
switch(config)# show udld global
5.
switch(config)# interface type slot/port
6.
switch(config-if)# udld {enable | disable | aggressive}
7.
switch(config-if)# show udld interface
DETAILED STEPS
Command or Action | Purpose | |
---|---|---|
Step 1 | switch# configure terminal |
Enters configuration mode. |
Step 2 | switch(config)# feature udld |
Enables UDLD for the device. |
Step 3 | switch(config)# no feature udld |
Disables UDLD for the device. |
Step 4 | switch(config)# show udld global |
Displays the UDLD status for the device. |
Step 5 | switch(config)# interface type slot/port |
Specifies an interface to configure, and enters interface configuration mode. |
Step 6 | switch(config-if)# udld {enable | disable | aggressive} |
Enables the normal UDLD mode, disables UDLD, or enables the aggressive UDLD mode. |
Step 7 | switch(config-if)# show udld interface |
Displays the UDLD status for the interface. |
This example shows how to enable the UDLD for the switch:
switch# configure terminal
switch(config)# feature udld
This example shows how to enable the normal UDLD mode for an Ethernet port:
switch# configure terminal
switch(config)# interface ethernet 1/4
switch(config-if)# udld enable
This example shows how to enable the aggressive UDLD mode for an Ethernet port:
switch# configure terminal
switch(config)# interface ethernet 1/4
switch(config-if)# udld aggressive
This example shows how to disable UDLD for an Ethernet port:
switch# configure terminal
switch(config)# interface ethernet 1/4
switch(config-if)# udld disable
This example shows how to disable UDLD for the switch:
switch# configure terminal
switch(config)# no feature udld
Configuring Interface Speed
The first 8 ports of a Cisco Nexus 5010 switch and the first 16 ports of a Cisco Nexus 5020 switch are switchable 1-Gigabit and 10-Gigabit ports. The default interface speed is 10-Gigabit. To configure these ports for 1-Gigabit Ethernet, insert a 1-Gigabit Ethernet SFP transceiver into the applicable port and then set its speed with the speed command.
To configure a 1-Gigabit Ethernet port, perform this task:
2.
switch(config)# interface type slot/port
3.
switch(config-if)# speed speed
DETAILED STEPS
Command or Action | Purpose | |
---|---|---|
Step 1 | switch# configure terminal |
Enters configuration mode. |
Step 2 | switch(config)# interface type slot/port |
Enters interface configuration mode for the specified interface. This interface must have a 1-Gigabit Ethernet SFP transceiver inserted into it. |
Step 3 | switch(config-if)# speed speed |
Sets the speed on the interface. |
The following example shows how to set the speed for a 1-Gigabit Ethernet port:
switch# configure terminal
switch(config)# interface ethernet 1/4
switch(config-if)# speed 1000
This command can only be applied to a physical Ethernet interface.
Note |
If the interface and transceiver speed is mismatched, the SFP validation failed message is displayed when you enter the show interface ethernet slot/port command. For example, if you insert a 1-Gigabit SFP transceiver into a port without configuring the speed 1000 command, you will get this error. By default, all ports are 10 Gigabits. |
Configuring the Cisco Discovery Protocol
Configuring the CDP Characteristics
You can configure the frequency of Cisco Discovery Protocol (CDP) updates, the amount of time to hold the information before discarding it, and whether or not to send Version-2 advertisements.
To configure CDP characteristics for an interface, perform this task:
2.
(Optional) switch(config)# [no] cdp advertise {v1 | v2 }
3.
(Optional) switch(config)# [no] cdp format device-id {mac-address | serial-number | system-name}
4.
(Optional) switch(config)# [no] cdp holdtime seconds
5.
(Optional) switch(config)# [no] cdp timer seconds
DETAILED STEPS
Command or Action | Purpose | |
---|---|---|
Step 1 | switch# configure terminal |
Enters configuration mode. |
Step 2 | switch(config)# [no] cdp advertise {v1 | v2 } |
(Optional) Configures the version to use to send CDP advertisements. Version-2 is the default state. Use the no form of the command to return to its default setting. |
Step 3 | switch(config)# [no] cdp format device-id {mac-address | serial-number | system-name} |
(Optional) Configures the format of the CDP device ID. The default is the system name, which can be expressed as a fully qualified domain name. Use the no form of the command to return to its default setting. |
Step 4 | switch(config)# [no] cdp holdtime seconds |
(Optional) Specifies the amount of time a receiving device should hold the information sent by your device before discarding it. The range is 10 to 255 seconds; the default is 180 seconds. Use the no form of the command to return to its default setting. |
Step 5 | switch(config)# [no] cdp timer seconds |
(Optional) Sets the transmission frequency of CDP updates in seconds. The range is 5 to 254; the default is 60 seconds. Use the no form of the command to return to its default setting. |
This example shows how to configure CDP characteristics:
switch# configure terminal
switch(config)# cdp timer 50
switch(config)# cdp holdtime 120
switch(config)# cdp advertise v2
Enabling or Disabling CDP
You can enable or disable CDP for Ethernet interfaces. This protocol works only when you have it enabled on both interfaces on the same link.
To enable or disable CDP for an interface, perform this task:
2.
switch(config)# interface type slot/port
3.
switch(config-if)# cdp enable
4.
switch(config-if)# no cdp enable
DETAILED STEPS
Command or Action | Purpose | |
---|---|---|
Step 1 | switch# configure terminal |
Enters configuration mode. |
Step 2 | switch(config)# interface type slot/port |
Enters interface configuration mode for the specified interface. |
Step 3 | switch(config-if)# cdp enable |
Enables CDP for the interface. To work correctly, this parameter must be enabled for both interfaces on the same link. |
Step 4 | switch(config-if)# no cdp enable |
Disables CDP for the interface. |
The following example shows how to enable CDP for an Ethernet port:
switch# configure terminal
switch(config)# interface ethernet 1/4
switch(config-if)# cdp enable
This command can only be applied to a physical Ethernet interface.
Enabling the Error-Disabled Detection
You can enable error-disable (err-disabled) detection in an application. As a result, when a cause is detected on an interface, the interface is placed in an err-disabled state, which is an operational state that is similar to the link-down state.
2.
errdisable detect cause {all | link-flap | loopback}
5.
show interface status err-disabled
6.
copy running-config startup-config
DETAILED STEPS
Command or Action | Purpose | |
---|---|---|
Step 1 | config t Example: switch# config t switch(config)# |
Enters configuration mode. |
Step 2 | errdisable detect cause {all | link-flap | loopback} Example: switch(config)# errdisable detect cause all switch(config)# |
Specifies a condition under which to place the interface in an err-disabled state. The default is enabled. |
Step 3 | shutdown Example: switch(config)# shutdown switch(config)# |
Brings the interface down administratively. To manually recover the interface from the err-disabled state, enter this command first. |
Step 4 | no shutdown Example: switch(config)# no shutdown switch(config)# |
Brings the interface up administratively and enables the interface to recover manually from the err-disabled state. |
Step 5 | show interface status err-disabled Example: switch(config)# show interface status err-disabled |
Displays information about err-disabled interfaces. |
Step 6 | copy running-config startup-config Example: switch(config)# copy running-config startup-config |
(Optional) Copies the running configuration to the startup configuration. |
This example shows how to enable the err-disabled detection in all cases:
switch(config)#errdisable detect cause all switch(config)#
Enabling the Error-Disabled Recovery
You can specify the application to bring the interface out of the error-disabled (err-disabled) state and retry coming up. It retries after 300 seconds, unless you configure the recovery timer (see the errdisable recovery interval command).
2.
errdisable recovery cause {all | udld | bpduguard | link-flap | failed-port-state | pause-rate-limit}
3.
show interface status err-disabled
4.
copy running-config startup-config
DETAILED STEPS
Command or Action | Purpose | |
---|---|---|
Step 1 | config t Example: switch#config t switch(config)# |
Enters configuration mode. |
Step 2 | errdisable recovery cause {all | udld | bpduguard | link-flap | failed-port-state | pause-rate-limit} Example: switch(config)#errdisable recovery cause all switch(config-if)# |
Specifies a condition under which the interface automatically recovers from the err-disabled state, and the device retries bringing the interface up. The device waits 300 seconds to retry. The default is disabled. |
Step 3 | show interface status err-disabled Example: switch(config)#show interface status err-disabled |
Displays information about err-disabled interfaces. |
Step 4 | copy running-config startup-config Example: switch(config)#copy running-config startup-config |
(Optional) Copies the running configuration to the startup configuration. |
This example shows how to enable err-disabled recovery under all conditions:
switch(config)#errdisable recovery cause all switch(config)#
Configuring the Error-Disabled Recovery Interval
You can use this procedure to configure the err-disabled recovery timer value. The range is from 30 to 65535 seconds. The default is 300 seconds.
2.
errdisable recovery interval interval
3.
show interface status err-disabled
4.
copy running-config startup-config
DETAILED STEPS
Command or Action | Purpose | |
---|---|---|
Step 1 | config t Example: switch#config t switch(config)# |
Enters configuration mode. |
Step 2 | errdisable recovery interval interval Example: switch(config)#errdisable recovery interval 32 switch(config-if)# |
Specifies the interval for the interface to recover from the err-disabled state. The range is from 30 to 65535 seconds. The default is 300 seconds. |
Step 3 | show interface status err-disabled Example: switch(config)#show interface status err-disabled |
Displays information about err-disabled interfaces. |
Step 4 | copy running-config startup-config Example: switch(config)#copy running-config startup-config |
(Optional) Copies the running configuration to the startup configuration. |
This example shows how to enable err-disabled recovery under all conditions:
switch(config)#errdisable recovery cause all switch(config)#
Configuring the Debounce Timer
You can enable the debounce timer for Ethernet ports by specifying a debounce time (in milliseconds) or disable the timer by specifying a debounce time of 0.
You can show the debounce times for all of the Ethernet ports by using the show interface debounce command.
To enable or disable the debounce timer, perform this task:
2.
switch(config)# interface type slot/port
3.
switch(config-if)# link debounce time milliseconds
DETAILED STEPS
Command or Action | Purpose | |
---|---|---|
Step 1 | switch# configure terminal |
Enters configuration mode. |
Step 2 | switch(config)# interface type slot/port |
Enters interface configuration mode for the specified interface. |
Step 3 | switch(config-if)# link debounce time milliseconds |
Enables the debounce timer for the amount of time (1 to 5000 milliseconds) specified. Disables the debounce timer if you specify 0 milliseconds. |
This example shows how to enable the debounce timer and set the debounce time to 1000 milliseconds for an Ethernet interface:
switch# configure terminal
switch(config)# interface ethernet 1/4
switch(config-if)# link debounce time 1000
This example shows how to disable the debounce timer for an Ethernet interface:
switch# configure terminal
switch(config)# interface ethernet 1/4
switch(config-if)# link debounce time 0
This command can only be applied to a physical Ethernet interface.
Configuring the Description Parameter
To provide textual interface descriptions for the Ethernet ports, perform this task:
2.
switch(config)# interface type slot/port
3.
switch(config-if)# description test
DETAILED STEPS
Command or Action | Purpose | |
---|---|---|
Step 1 | switch# configure terminal |
Enters configuration mode. |
Step 2 | switch(config)# interface type slot/port |
Enters interface configuration mode for the specified interface. |
Step 3 | switch(config-if)# description test |
Specifies the description for the interface. |
This example shows how to set the interface description to "Server 3 Interface."
switch# configure terminal
switch(config)# interface ethernet 1/3
switch(config-if)# description Server 3 Interface
Disabling and Restarting Ethernet Interfaces
You can shut down and restart an Ethernet interface. This action disables all of the interface functions and marks the interface as being down on all monitoring displays.
To disable an interface, perform this task:
2.
switch(config)# interface type slot/port
3.
switch(config-if)# shutdown
4.
switch(config-if)# no shutdown
DETAILED STEPS
Command or Action | Purpose | |
---|---|---|
Step 1 | switch# configure terminal |
Enters configuration mode. |
Step 2 | switch(config)# interface type slot/port |
Enters interface configuration mode for the specified interface. |
Step 3 | switch(config-if)# shutdown |
Disables the interface. |
Step 4 | switch(config-if)# no shutdown |
Restarts the interface. |
The following example shows how to disable an Ethernet port:
switch# configure terminal
switch(config)# interface ethernet 1/4
switch(config-if)# shutdown
The following example shows how to restart an Ethernet interface:
switch# configure terminal
switch(config)# interface ethernet 1/4
switch(config-if)# no shutdown
Displaying Interface Information
To view configuration information about the defined interfaces, perform one of these tasks:
Command |
Purpose |
---|---|
switch# show interface type slot/port | Displays the detailed configuration of the specified interface. |
switch# show interface type slot/port capabilities | Displays detailed information about the capabilities of the specified interface. This option is only available for physical interfaces |
switch# show interface type slot/port transceiver | Displays detailed information about the transceiver connected to the specified interface. This option is only available for physical interfaces. |
switch# show interface brief | Displays the status of all interfaces. |
switch# show interface debounce | Displays the debounce status of all interfaces. |
switch# show interface flowcontrol | Displays the detailed listing of the flow control settings on all interfaces. |
The show interface command is invoked from EXEC mode and displays the interface configurations. Without any arguments, this command displays the information for all the configured interfaces in the switch.
The following example shows how to display the physical Ethernet interface:
switch# show interface ethernet 1/1
Ethernet1/1 is up
Hardware is 1000/10000 Ethernet, address is 000d.eca3.5f08 (bia 000d.eca3.5f08)
MTU 1500 bytes, BW 10000000 Kbit, DLY 10 usec,
reliability 255/255, txload 190/255, rxload 192/255
Encapsulation ARPA
Port mode is trunk
full-duplex, 10 Gb/s, media type is 1/10g
Input flow-control is off, output flow-control is off
Auto-mdix is turned on
Rate mode is dedicated
Switchport monitor is off
Last clearing of "show interface" counters never
5 minute input rate 942201806 bytes/sec, 14721892 packets/sec
5 minute output rate 935840313 bytes/sec, 14622492 packets/sec
Rx
129141483840 input packets 0 unicast packets 129141483847 multicast packets
0 broadcast packets 0 jumbo packets 0 storm suppression packets
8265054965824 bytes
0 No buffer 0 runt 0 Overrun
0 crc 0 Ignored 0 Bad etype drop
0 Bad proto drop
Tx
119038487241 output packets 119038487245 multicast packets
0 broadcast packets 0 jumbo packets
7618463256471 bytes
0 output CRC 0 ecc
0 underrun 0 if down drop 0 output error 0 collision 0 deferred
0 late collision 0 lost carrier 0 no carrier
0 babble
0 Rx pause 8031547972 Tx pause 0 reset
The following example shows how to display the physical Ethernet capabilities:
switch# show interface ethernet 1/1 capabilities
Ethernet1/1
Model: 734510033
Type: 10Gbase-(unknown)
Speed: 1000,10000
Duplex: full
Trunk encap. type: 802.1Q
Channel: yes
Broadcast suppression: percentage(0-100)
Flowcontrol: rx-(off/on),tx-(off/on)
Rate mode: none
QOS scheduling: rx-(6q1t),tx-(1p6q0t)
CoS rewrite: no
ToS rewrite: no
SPAN: yes
UDLD: yes
Link Debounce: yes
Link Debounce Time: yes
MDIX: no
FEX Fabric: yes
The following example shows how to display the physical Ethernet transceiver:
switch# show interface ethernet 1/1 transceiver
Ethernet1/1
sfp is present
name is CISCO-EXCELIGHT
part number is SPP5101SR-C1
revision is A
serial number is ECL120901AV
nominal bitrate is 10300 MBits/sec
Link length supported for 50/125mm fiber is 82 m(s)
Link length supported for 62.5/125mm fiber is 26 m(s)
cisco id is --
cisco extended id number is 4
The following example shows how to display a brief interface status (some of the output has been removed for brevity):
switch# show interface brief
--------------------------------------------------------------------------------
Ethernet VLAN Type Mode Status Reason Speed Port
Interface Ch #
--------------------------------------------------------------------------------
Eth1/1 200 eth trunk up none 10G(D) --
Eth1/2 1 eth trunk up none 10G(D) --
Eth1/3 300 eth access down SFP not inserted 10G(D) --
Eth1/4 300 eth access down SFP not inserted 10G(D) --
Eth1/5 300 eth access down Link not connected 1000(D) --
Eth1/6 20 eth access down Link not connected 10G(D) --
Eth1/7 300 eth access down SFP not inserted 10G(D) --
...
The following example shows how to display the link debounce status (some of the output has been removed for brevity):
switch# show interface debounce
--------------------------------------------------------------------------------
Port Debounce time Value(ms)
--------------------------------------------------------------------------------
...
Eth1/1 enable 100
Eth1/2 enable 100
Eth1/3 enable 100
...
The following example shows how to display the CDP neighbors:
switch# show cdp neighbors
Capability Codes: R - Router, T - Trans-Bridge, B - Source-Route-Bridge
S - Switch, H - Host, I - IGMP, r - Repeater,
V - VoIP-Phone, D - Remotely-Managed-Device,
s - Supports-STP-Dispute
Device ID Local Intrfce Hldtme Capability Platform Port ID
d13-dist-1 mgmt0 148 S I WS-C2960-24TC Fas0/9
n5k(FLC12080012) Eth1/5 8 S I s N5K-C5020P-BA Eth1/5
Note |
From Cisco NX-OS Release 4.0(1a)N1(1), the default value of the device ID field for CDP advertisement has been changed from the chassis serial number to the hostname and serial number, as in the example above. |
Default Physical Ethernet Settings
The following table lists the default settings for all physical Ethernet interfaces:
Parameter |
Default Setting |
---|---|
Debounce |
Enable, 100 milliseconds |
Duplex |
Auto (full-duplex) |
Encapsulation |
ARPA |
MTU1 |
1500 bytes |
Port Mode |
Access |
Speed |
Auto (10000) |