Information About CFS
Some features in the Cisco Nexus Series switch require configuration synchronization with other switches in the network to function correctly. Synchronization through manual configuration at each switch in the network can be a tedious and error-prone process.
Cisco Fabric Services (CFS) provides a common infrastructure for automatic configuration synchronization in the network. It provides the transport function and a set of common services to the features. CFS has the ability to discover CFS-capable switches in the network and to discover feature capabilities in all CFS-capable switches.
Cisco Nexus Series switches support CFS message distribution over Fibre Channel and IPv4 or IPv6 networks. If the switch is provisioned with Fibre Channel ports, CFS over Fibre Channel is enabled by default while CFS over IP must be explicitly enabled.
CFS provides the following features:
-
Peer-to-peer protocol with no client-server relationship at the CFS layer.
-
CFS message distribution over Fibre Channel and IPv4 or IPv6 networks.
-
Three modes of distribution.
-
Coordinated distributions—Only one distribution is allowed in the network at any given time.
-
Uncoordinated distributions—Multiple parallel distributions are allowed in the network except when a coordinated distribution is in progress.
-
Unrestricted uncoordinated distributions—Multiple parallel distributions are allowed in the network in the presence of an existing coordinated distribution. Unrestricted uncoordinated distributions are allowed to run in parallel with all other types of distributions.
-
The following features are supported for CFS distribution over IP:
-
One scope of distribution over an IP network:
-
Physical scope—The distribution spans the entire IP network.
-
The following features are supported for CFS distribution over Fibre Channel SANs:
-
Three scopes of distribution over SAN fabrics.
-
Logical scope — The distribution occurs within the scope of a VSAN.
-
Physical scope — The distribution spans the entire physical topology.
-
Over a selected set of VSANs — Some features require configuration distribution over some specific VSANs. These features can specify to CFS the set of VSANs over which to restrict the distribution.
-
-
Supports a merge protocol that facilitates the merge of feature configuration during a fabric merge event (when two independent SAN fabrics merge).
Cisco Fabric Services over Ethernet
The Cisco Fabric Services over Ethernet (CFSoE) is a reliable state transport mechanism that you can use to synchronize the actions of the vPC peer devices. CFSoE carries messages and packets for many features linked with vPC, such as STP and IGMP. Information is carried in CFS/CFSoE protocol data units (PDUs).
When you enable the vPC feature, the device automatically enables CFSoE, and you do not have to configure anything. CFSoE distributions for vPCs do not need the capabilities to distribute over IP or the CFS regions. You do not need to configure anything for the CFSoE feature to work correctly on vPCs.
You can use the show mac address-table command to display the MAC addresses that CFSoE synchronizes for the vPC peer link.
Note |
Do not enter the no cfs eth distribute or the no cfs distribute command. CFSoE must be enabled for vPC functionality. If you do enter either of these commands when vPC is enabled, the system displays an error message. |
When you enter the show cfs application command, the output displays "Physical-eth," which shows the applications that are using CFSoE.