Technical Specifications

This appendix contains these topics:

Physical Specifications

Physical Dimensions for Cisco Catalyst 1000 Series Switches

Weight



  • 3.96 lbs (1.8 kg) (C1000-8T-2G-L)

  • 3.41 lbs (1.55 kg) (C1000-8T-E-2G-L)

  • 5.95 lbs (2.7 kg) (C1000-8P-2G-L)

  • 3.41 lbs (1.55 kg) (C1000-8P-E-2G-L)

  • 5.95 lbs (2.7 kg) (C1000-8FP-2G-L)

  • 3.41 lbs (1.55 kg) (C1000-8FP-E-2G-L)

  • 3.92 lbs (1.78 kg) (C1000-16T-2G-L)

  • 3.13 lbs (1.42 kg) (C1000-16T-E-2G-L)

  • 5.24 lbs (2.38 kg) (C1000-16P-2G-L)

  • 3.13 lbs (1.42 kg) (C1000-16P-E-2G-L)

  • 5.48 lbs (2.49 kg) (C1000-16FP-2G-L)

Dimensions (W x D x H)

  • 10.56 x 7.28 x 1.73 in (C1000-8T-2G-L)

  • 10.56 x 7.28 x 1.73 in (C1000-8T-E-2G-L)

  • 10.56 x 12.73 x 1.73 in (C1000-8P-2G-L)

  • 10.56 x 7.28 x 1.73 in (C1000-8P-E-2G-L)

  • 10.56 x 12.73 x 1.73 in (C1000-8FP-2G-L)

  • 10.56 x 7.28 x 1.73 in (C1000-8FP-E-2G-L)

  • 10.56 x 10.69 x 1.73 in (C1000-16T-2G-L)

  • 10.56 x 8.26 x 1.73 in (C1000-16T-E-2G-L)

  • 10.56 x 11.69 x 1.73 in (C1000-16P-2G-L)

  • 10.56 x 8.26 x 1.73 in (C1000-16P-E-2G-L)

  • 10.56 x 12.14 x 1.73 in (C1000-16FP-2G-L)

Environmental Specifications

Environmental Ranges

Operating temperature

1

23 to 122°F (–5 to 50°C) up to 5,000 ft (1524 m)


Storage temperature

-13º to 158ºF (-25º to 70ºC) up to 15,000 ft (4572 m)

Operating relative humidity

5% to 90% (noncondensing)

Storage relative humidity

5% to 95% (noncondensing)

Storage altitude

Up to 15,000 ft (4572 m)

1 Minimum ambient temperature for cold start is 32°F (0°C)

Note

When using the Cisco Catalyst 1000 series 8-port and 16-port switches with GLC-BX-U or GLC-BX-D SFP module, the thermal limitations are as follows:

  • Up to 5,000 ft (1524 m), the operation temperature should not exceed 113°F (45°C).

  • Up to 10,000 ft (3048 m), the operation temperature should not exceed 104°F (40°C).


Power Requirements

Table 1. Power Requirements

Switch Model

Voltage (auto ranging)

Frequency

Current

Power Rating (maximum consumption)

C1000-8T-2G-L

100 to 240V AC in

50 to 60 Hz

0.15A to 0.25A

0.016 kVA

C1000-8T-E-2G-L

100 to 240V AC in

50 to 60 Hz

0.16A to 0.26A

0.017 kVA

C1000-8P-2G-L

100 to 240V AC in

50 to 60 Hz

0.23A to 0.27A

0.089 kVA

C1000-8P-E-2G-L

100 to 240V AC in

50 to 60 Hz

0.22A to 0.37A

0.087 kVA

C1000-8FP-2G-L

100 to 240V AC in

50 to 60 Hz

0.23A to 0.28A

0.015 kVA

C1000-8FP-E-2G-L

100 to 240V AC in

50 to 60 Hz

0.15A to 0.20A

0.015 kVA

C1000-16T-2G-L

100 to 240V AC in

50 to 60 Hz

0.24A to 0.38A

0.08 kVA

C1000-16T-E-2G-L

100 to 240V AC in

50 to 60 Hz

0.19A to 0.31A

0.05 kVA

C1000-16P-2G-L

100 to 240V AC in

50 to 60 Hz

0.22A to 0.27A

0.25 kVA

C1000-16P-E-2G-L

100 to 240V AC in

50 to 60 Hz

0.14A to 0.24A

0.20 kVA

C1000-16FP-2G-L

100 to 240V AC in

50 to 60 Hz

0.35A to 0.37A

0.45 kVA

PoE Power Consumption

Switch Model

Consumption without PoE (Watts)

Consumption with PoE (Watts)

Available PoE

Maximum Power Wattage for BTU/hr

C1000-8T-2G-L

14.26

-

-

16.249

C1000-8T-E-2G-L

14

-

-

16.78

C1000-8P-2G-L

12.19

80.24

67

89.71

C1000-8P-E-2G-L

15.71

67.82

67

87.78

C1000-8FP-2G-L

14.52

138.15

120

156.15

C1000-8FP-E-2G-L

15.7

141.16

120

153.35

C1000-16T-2G-L

16.68

-

-

18.89

C1000-16T-E-2G-L

16.68

-

-

18.92

C1000-16P-2G-L

16.92

136.92

120

40.7

C1000-16P-E-2G-L

16.32

136.32

120

36.68

C1000-16FP-2G-L

16.8

256.8

240

54.4