Technical Specifications
This appendix lists the switch technical specifications in these tables:
•Specifications for the Catalyst 3750G-12S Switch, Table A-1
•Specifications for the Catalyst 3750G-12S-SD Switch, Table A-2
•Specifications for the Catalyst 3750-24FS Switch, Table A-3
•Specifications for the Catalyst 3750-24TS Switch, Table A-4
•Specifications for the Catalyst 3750G-24T Switch, Table A-5
•Specifications for the Catalyst 3750-24PS Switch, Table A-6
•Specifications for the Catalyst 3750G-24PS Switch, Table A-7
•Specifications for the Catalyst 3750-48PS Switch, Table A-8
•Specifications for the Catalyst 3750G-48PS Switch, Table A-9
•Specifications for the Catalyst 3750G-16TD Switch, Table A-10
•Specifications for the Catalyst 3750G-24TS Switch, Table A-11
•Specifications for the Catalyst 3750G-24TS-1U Switch, Table A-12
•Specifications for the Catalyst 3750-48TS Switch, Table A-13
•Specifications for the Catalyst 3750G-48TS Switch, Table A-14
•Specifications for the Catalyst 3750G-24WS-S25 and 3750G-24WS-S50 Switch, Table A-14
•Specifications for the Catalyst 3750V2-48PS and 3750V2-24PS Switch, Table A-16
•Specifications for the Catalyst 3750V2-48TS and 3750V2-24TS Switch, Table A-17
•Specifications for the Catalyst 3750V2-24FS Switch, Table A-18
Table A-1 Specifications for the Catalyst 3750G-12S Switch
|
Operating temperature |
32 to 113°F (0 to 45°C) |
Storage temperature |
-13 to 158°F (-25 to 70°C) |
Relative humidity |
10 to 85% (noncondensing) |
Operating altitude |
Up to 10,000 ft (3049 m) |
Storage altitude |
Up to 15,000 ft (4573 m) |
|
AC input voltage |
100 to 240 VAC (autoranging) 0.6 to 1.2 A, 50 to 60 Hz |
DC input voltages for RPS 2300 and 675 |
+12 V@13 A |
Power consumption |
120 W, 409 BTUs per hour |
Power rating |
0.120 kVA |
|
Weight |
10 lb (4.6 kg) |
Dimensions (H x W x D) |
1.73 x 17.5 x 12.8 in. (4.4 x 44.5 x 32.6 cm) |
Table A-2 Specifications for the Catalyst 3750G-12S-SD Switch
|
Operating temperature |
32 to 113°F (0 to 45°C) |
Storage temperature |
-13 to 158°F (-25 to 70°C) |
Relative humidity |
10 to 85% (noncondensing) |
Operating altitude |
Up to 10,000 ft (3049 m) |
Storage altitude |
Up to 15,000 ft (4573 m) |
|
DC input voltage |
-36 to -72 VDC 3 to 1.5 A |
Power consumption |
94 W, 321 BTUs per hour |
|
Weight |
10 lb (4.6 kg) |
Dimensions (H x W x D) |
1.73 x 17.5 x 12.8 in. (4.4 x 44.5 x 32.6 cm) |
Table A-3 Specifications for the Catalyst 3750-24FS Switch
|
Operating temperature |
32 to 113°F (0 to 45°C) |
Storage temperature |
-13 to 158°F (-25 to 70°C) |
Relative humidity |
10 to 85% (noncondensing) |
Operating altitude |
Up to 10,000 ft (3049 m) |
Storage altitude |
Up to 15,000 ft (4573 m) |
|
AC input voltage |
100 to 240 VAC (autoranging) 1.5 to 3 A, 50 to 60 Hz |
DC input voltages for RPS 2300 and 675 |
+12 V@8.5 A |
Power consumption |
70 W, 240 BTUs per hour |
Power rating |
0.070 kVA |
|
Weight |
9 lb (4.1 kg) |
Dimensions (H x W x D) |
1.73 x 17.5 x 11.8 in. (4.4 x 44.5 x 30.1 cm) |
Table A-4 Specifications for the Catalyst 3750-24TS Switch
|
Operating temperature |
32 to 113°F (0 to 45°C) |
Storage temperature |
-13 to 158°F (-25 to 70°C) |
Relative humidity |
10 to 85% (noncondensing) |
Operating altitude |
Up to 10,000 ft (3049 m) |
Storage altitude |
Up to 15,000 ft (4573 m) |
|
AC input voltage |
100 to 240 VAC (autoranging) 0.6 to 1.2 A, 50 to 60 Hz |
DC input voltages for RPS 2300 and 675 |
+12 V@8.5 A |
Power consumption |
50 W, 171 BTUs per hour |
Power rating |
0.083 kVA |
|
Weight |
8 lb (3.6 kg) |
Dimensions (H x W x D) |
1.73 x 17.5 x 11.8 in. (4.4 x 44.5 x 30.1 cm) |
Table A-5 Specifications for the Catalyst 3750G-24T Switch
|
Operating temperature |
32 to 113°F (0 to 45°C) |
Storage temperature |
-13 to 158°F (-25 to 70°C) |
Relative humidity |
10 to 85% (noncondensing) |
Operating altitude |
Up to 10,000 ft (3049 m) |
Storage altitude |
Up to 15,000 ft (4573 m) |
|
AC input voltage |
100 to 240 VAC (autoranging) 0.9 to 1.6 A, 50 to 60 Hz |
DC input voltages for RPS 2300 and 675 |
+12 V@13 A |
Power consumption |
165 W, 563 BTUs per hour |
Power rating |
0.165 kVA |
Physical Dimensions |
Weight |
10 lb (4.6 kg) |
Dimensions (H x W x D) |
1.73 x 17.5 x 12.8 in. (4.4 x 44.5 x 32.6 cm) |
Table A-6 Specifications for the Catalyst 3750-24PS Switch
Environmental Ranges |
Operating temperature |
32 to 113°F (0 to 45°C) |
Storage temperature |
-13 to 158°F (-25 to 70°C) |
Relative humidity |
10 to 85% (noncondensing) |
Operating altitude |
Up to 10,000 ft (3049 m) |
Storage altitude |
Up to 15,000 ft (4573 m) |
|
AC input voltage |
100 to 240 VAC (autoranging) 2.9 to 5.5 A, 50 to 60 Hz |
DC input voltage for RPS 2300 and 675 |
+12 V@7.5 A and -48 V@7.8 A |
Power consumption |
495 W |
Power dissipation |
125 W, 426 BTUs per hour |
Power rating |
0.495 kVA |
|
15.4 W per port maximum, 370 W switch maximum |
|
Weight |
11.3 lb (5.1 kg) |
Dimensions (H x W x D) |
1.73 x 17.5 x 11.8 in. (4.4 x 44.5 x 30.1 cm) |
Table A-7 Specifications for the Catalyst 3750G-24PS Switch
|
Operating temperature |
32 to 113°F (0 to 45°C) |
Storage temperature |
-13 to 158°F (-25 to 70°C) |
Relative humidity |
10 to 85% (noncondensing) |
Operating altitude |
Up to 10,000 ft (3049 m) |
Storage altitude |
Up to 15,000 ft (4573 m) |
|
AC input voltage |
100 to 240 VAC (autoranging) 4 to 8 A, 50 to 60 Hz |
DC input voltages for RPS 2300 and 675 |
+12 V@14 A and -48 V@7.8 A |
Power consumption |
520 W |
Power dissipation |
170 W, 534 BTUs per hour |
Power rating |
0.52 kVA |
Power over Ethernet |
Range from 4 to 15.4 W per port, up to 370 W switch maximum |
Physical Dimensions |
Weight |
13.5 lb (6.1 kg) |
Dimensions (H x W x D) |
1.73 x 17.5 x 14.9 in. (4.4 x 44.5 x 37.8 cm) |
Table A-8 Specifications for the Catalyst 3750-48PS Switch
|
Operating temperature |
32 to 113°F (0 to 45°C) |
Storage temperature |
-13 to 158°F (-25 to 70°C) |
Relative humidity |
10 to 85% (noncondensing) |
Operating altitude |
Up to 10,000 ft (3049 m) |
Storage altitude |
Up to 15,000 ft (4573 m) |
|
AC input voltage |
100 to 240 VAC (autoranging) 4 to 8 A, 50 to 60 Hz |
DC input voltages for RPS 2300 and 675 |
+12 V@7.5 A and -48 V@7.8 A |
Power consumption |
540 W |
Power dissipation |
170 W, 580 BTUs per hour |
Power rating |
0.54 kVA |
Power over Ethernet |
Range from 4 to 15.4 W per port, up to 370 W switch maximum |
Physical Dimensions |
Weight |
13.2 lb (6 kg) |
Dimensions (H x W x D) |
1.73 x 17.5 x 14.8 in. (4.4 x 44.5 x 37.8 cm) |
Table A-9 Specifications for the Catalyst 3750G-48PS Switch
|
Operating temperature |
32 to 113°F (0 to 45°C) |
Storage temperature |
-13 to 158°F (-25 to 70°C) |
Relative humidity |
10 to 85% (noncondensing) |
Operating altitude |
Up to 10,000 ft (3049 m) |
Storage altitude |
Up to 15,000 ft (4573 m) |
|
AC input voltage |
100 to 240 VAC (autoranging) 4 to 8 A, 50 to 60 Hz |
DC input voltages for RPS 2300 and 675 |
+12 V@14 A and -48 V@7.8 A |
Power consumption |
560 W |
Power dissipation |
220 W, 690 BTUs per hour |
Power rating |
0.56 kVA |
Power over Ethernet |
Range from 4 to 15.4 W per port, up to 370 W switch maximum |
Physical Dimensions |
Weight |
15.5 lb (7 kg) |
Dimensions (H x W x D) |
1.73 x 17.5 x 16.1 in. (4.4 x 44.5 x 40.9 cm) |
Table A-10 Specifications for the Catalyst 3750G-16TD Switch
|
Operating temperature |
32 to 113°F (0 to 45°C) |
Storage temperature |
-13 to 158°F (-25 to 70°C) |
Relative humidity |
10 to 85% (noncondensing) |
Operating altitude |
Up to 10,000 ft (3049 m) |
Storage altitude |
Up to 15,000 ft (4573 m) |
|
AC input voltage |
100 to 240 VAC (autoranging) 0.9 to 1.6 A, 50 to 60 Hz |
DC input voltages for RPS 2300 and 675 |
+12 V@17 A |
Power consumption |
180 W, 615 BTUs per hour |
Power rating |
0.180 kVA |
Physical Dimensions |
Weight |
12.5 lb (5.7 kg) |
Dimensions (H x W x D) |
1.73 x 17.5 x 16.1 in. (4.4 x 44.5 x 40.9 cm) |
Table A-11 Specifications for the Catalyst 3750G-24TS Switch
|
Operating temperature |
32 to 113°F (0 to 45°C) |
Storage temperature |
-13 to 158°F (-25 to 70°C) |
Relative humidity |
10 to 85% (noncondensing) |
Operating altitude |
Up to 10,000 ft (3049 m) |
Storage altitude |
Up to 15,000 ft (4573 m) |
|
AC input voltage |
100 to 240 VAC (autoranging) 1.5 to 2.3 A, 50 to 60 Hz |
DC input voltages for RPS 2300 and 675 |
+12 V@17 A |
Power consumption |
190 W, 650 BTUs per hour |
Power rating |
0.190 kVA |
Physical Dimensions |
Weight |
12.5 lb (5.7 kg) |
Dimensions (H x W x D) |
2.59 x 17.5 x 11.6 in. (6.6 x 44.5 x 29.5 cm) |
Table A-12 Specifications for the Catalyst 3750G-24TS-1U Switch
|
Operating temperature |
32 to 113°F (0 to 45°C) |
Storage temperature |
-13 to 158°F (-25 to 70°C) |
Relative humidity |
10 to 85% (noncondensing) |
Operating altitude |
Up to 10,000 ft (3049 m) |
Storage altitude |
Up to 15,000 ft (4573 m) |
|
AC input voltage |
100 to 240 VAC (autoranging) 1.5 to 3 A, 50 to 60 Hz |
DC input voltages for RPS 2300 and 675 |
+12 V@10.5 A |
Power consumption |
100 W |
Power dissipation |
100 W, 314 BTUs per hour |
Power rating |
0.10 kVA |
Physical Dimensions |
Weight |
12 lb (5.5 kg) |
Dimensions (H x W x D) |
1.73 x 17.5 x 14.9 in. (4.4 x 44.5 x 37.8 cm) |
Table A-13 Specifications for the Catalyst 3750-48TS Switch
|
Operating temperature |
32 to 113°F (0 to 45°C) |
Storage temperature |
-13 to 158°F (-25 to 70°C) |
Relative humidity |
10 to 85% (noncondensing) |
Operating altitude |
Up to 10,000 ft (3049 m) |
Storage altitude |
Up to 15,000 ft (4573 m) |
|
AC input voltage |
100 to 240 VAC (autoranging) 0.6 to 1.2 A, 50 to 60 Hz |
DC input voltages for RPS 2300 and 675 |
+12 V@8.5 A |
Power consumption |
75 W, 256 BTUs per hour |
Power rating |
0.075 kVA |
|
Weight |
9.1 lb (4.1 kg) |
Dimensions (H x W x D) |
1.73 x 17.5 x 11.8 in. (4.4 x 44.5 x 30.1 cm) |
Table A-14 Specifications for the Catalyst 3750G-48TS Switch
|
Operating temperature |
32 to 113°F (0 to 45°C) |
Storage temperature |
-13 to 158°F (-25 to 70°C) |
Relative humidity |
10 to 85% (noncondensing) |
Operating altitude |
Up to 10,000 ft (3049 m) |
Storage altitude |
Up to 15,000 ft (4573 m) |
|
AC input voltage |
100 to 240 VAC (autoranging) 1.5 to 3 A, 50 to 60 Hz |
DC input voltages for RPS 2300 and 675 |
+12 V@17.5 A |
Power consumption |
160 W |
Power dissipation |
160 W, 500 BTUs per hour |
Power rating |
0.16 kVA |
Physical Dimensions |
Weight |
14 lb (6.4 kg) |
Dimensions (H x W x D) |
1.73 x 17.5 x 16.1 in. (4.4 x 44.5 x 40.9 cm) |
Table A-15 Specifications for the Catalyst 3750G-24WS-S25 and 3750G-24WS-S50 Switch
|
Operating temperature |
32 to 113°F (0 to 45°C) |
Storage temperature |
-13 to 158°F (-25 to 70°C) |
Relative humidity |
10 to 85% (noncondensing) |
Operating altitude |
Up to 10,000 ft (3049 m) |
Storage altitude |
Up to 15,000 ft (4573 m) |
|
AC input voltage |
100 to 240 VAC (autoranging) 4 to 8 A, 50 to 60 Hz |
DC input voltages for RPS 2300 and 675 |
+ 12 V@14 A and -48 V@7.8 A |
Power consumption |
520 W |
Power dissipation |
190 W, 648 BTUs per hour |
Power rating |
0.52 kVA |
Power over Ethernet |
Range from 4 to 15.4 W per port, up to 370 W switch maximum |
Physical Dimensions |
Weight |
21 lb (9.5 kg) |
Dimensions (H x W x D) |
3.5 x 17.5 x 14.5in. (8.9 x 44.5 x 36.8 cm) |
Table A-16 Specifications for the Catalyst 3750V2-48PS and 3750V2-24PS Switch
|
Operating temperature |
32 to 113°F (0 to 45°C) |
Storage temperature |
-13 to 158°F (-25 to 70°C) |
Relative humidity |
10 to 85% (noncondensing) |
Operating altitude |
Up to 10,000 ft (3049 m) |
Storage altitude |
Up to 15,000 ft (4573 m) |
|
AC input voltage |
100 to 240 VAC (autoranging) 4 to 8 A, 50 to 60 Hz |
DC input voltages for RPS 2300 and 675 |
+12 V@14 A and -48 V@7.8 A |
Power consumption |
560 W |
Power dissipation |
220 W, 690 BTUs per hour |
Power rating |
0.56 kVA |
Power over Ethernet |
Range from 4 to 15.4 W per port, up to 370 W switch maximum |
Physical Dimensions |
Weight |
11.3 lb (5.1 kg) |
Dimensions (H x W x D) |
1.73 x 17.5 x 11.8 in. (4.4 x 44.5 x 30.1 cm) |
Table A-17 Specifications for the Catalyst 3750V2-48TS and 3750V2-24TS Switch
|
Operating temperature |
32 to 113°F (0 to 45°C) |
Storage temperature |
-13 to 158°F (-25 to 70°C) |
Relative humidity |
10 to 85% (noncondensing) |
Operating altitude |
Up to 10,000 ft (3049 m) |
Storage altitude |
Up to 15,000 ft (4573 m) |
|
AC input voltage |
100 to 240 VAC (autoranging) 0.8 to 1.5 A, 50 to 60 Hz |
DC input voltages for RPS 2300 and 675 |
+12 V@17 A |
Power consumption |
180 W, 615 BTUs per hour |
Power rating |
0.180 kVA |
Physical Dimensions |
Weight |
12.5 lb (5.7 kg) |
Dimensions (H x W x D) |
1.73 x 17.5 x 11.6 in. (4.4 x 44.5 x 29.5 cm) |
Table A-18 Specifications for the Catalyst 3750V2-24FS Switch
|
Operating temperature |
32 to 113°F (0 to 45°C) |
Storage temperature |
-13 to 158°F (-25 to 70°C) |
Relative humidity |
10 to 85% (noncondensing) |
Operating altitude |
Up to 10,000 ft (3049 m) |
Storage altitude |
Up to 15,000 ft (4573 m) |
|
AC input voltage |
100 to 240 VAC (autoranging) 1 to 2 A, 50 to 60 Hz |
DC input voltages for RPS 2300 and 675 |
+12 V@11.3 A |
Power consumption |
55.2 W, 173 BTUs per hour |
Power rating |
0.052 kVA |
|
Weight |
9 lb (4.1 kg) |
Dimensions (H x W x D) |
1.73 x 17.5 x 11.8 in. (4.4 x 44.5 x 30.1 cm) |