- Preface
- Product Overview
- Command-line Interfaces
- Configuring the Switch for the First Time
- Administering the Switch
- Configuring the Cisco IOS In Service Software Upgrade Process
- Configuring Interfaces
- Checking Port Status and Connectivity
- Configuring Supervisor Engine Redundancy Using RPR and SSO
- Configuring Cisco NSF with SSO Supervisor Engine Redundancy
- Environmental Monitoring and Power Management
- Configuring Power over Ethernet
- Configuring Energy Wise
- Configuring the Catalyst 4500 Series Switch with Cisco Network Assistant
- Configuring VLANs, VTP, and VMPS
- Configuring IP Unnumbered Interface
- Configuring Layer 2 Ethernet Interfaces
- Configuring SmartPort Macros
- Configuring STP and MST
- Configuring Flex Links and the MAC Address-Table Move Update Feature
- Configuring Resilient Ethernet Protocol
- Configuring Optional STP Features
- Configuring EtherChannels
- Configuring IGMP Snooping and Filtering
- Configuring IPv6 MLD Snooping
- Configuring 802.1Q and Layer 2 Protocol Tunneling
- Configuring CDP
- Configuring LLDP and LLDP-MED
- Configuring UDLD
- Configuring Unidirectional Ethernet
- Configuring Layer 3 Interfaces
- Configuring Cisco Express Forwarding
- Configuring Unicast Reverse Path Forwarding
- Configuring IP Multicast
- Configuring ANCP Client
- Configuring Policy-Based Routing
- Configuring VRF-lite
- Configuring Quality of Service
- Configuring Voice Interfaces
- Configuring Private VLANs
- Configuring 802.1X Port-Based Authentication
- Configuring PPPoE Intermediate Agent
- Configuring Web-Based Authentication
- Configuring Port Security
- Configuring Control Plane Policing
- Configuring DHCP Snooping, IP Source Guard, and IPSG for Static Hosts
- Configuring Dynamic ARP Inspection
- Configuring Network Security with ACLs
- Port Unicast and Multicast Flood Blocking
- Configuring Storm Control
- Configuring SPAN and RSPAN
- Configuring System Message Logging
- Configuring SNMP
- Configuring NetFlow
- Configuring Ethernet CFM and OAM
- Configuring Y.1731 (AIS and RDI)
- Configuring Call Home
- Configuring Cisco IOS IP SLAs Operations
- Configuring RMON
- Performing Diagnostics
- Configuring WCCP Version 2 Services
- ROM Monitor
- Configuring MIB Support
- Index
- Acronyms
Configuring SNMP
This chapter describes how to configure the Simple Network Management Protocol (SNMP) on the Catalyst 4500 series switch.
This chapter consists of these sections:
Note For complete syntax and usage information for the commands used in this chapter, see the
Cisco IOS Configuration Fundamentals Command Reference
http://www.cisco.com/en/US/docs/ios/fundamentals/command/reference/cf_book.html
and related publications at this location:
http://www.cisco.com/en/US/products/ps6350/index.html
Understanding SNMP
SNMP is an application-layer protocol that provides a message format for communication between managers and agents. The SNMP system consists of an SNMP manager, an SNMP agent, and a MIB. The SNMP manager can be part of a network management system (NMS) such as CiscoWorks. The agent and MIB reside on the switch. To configure SNMP on the switch, you define the relationship between the manager and the agent.
The SNMP agent contains MIB variables whose values the SNMP manager can request or change. A manager can get a value from an agent or store a value into the agent. The agent gathers data from the MIB, the repository for information about device parameters and network data. The agent can also respond to a manager's requests to get or set data.
An agent can send unsolicited traps to the manager. Traps are messages alerting the SNMP manager to a condition on the network. Traps can mean improper user authentication, restarts, link status (up or down), MAC address tracking, closing of a Transmission Control Protocol (TCP) connection, loss of connection to a neighbor, or other significant events.
This section includes information about these topics:
•Using SNMP to Access MIB Variables
SNMP Versions
The Catalyst 4500 series switch supports these SNMP versions:
•SNMPv1—The Simple Network Management Protocol, a Full Internet Standard, defined in RFC 1157.
•SNMPv2C replaces the Party-based Administrative and Security Framework of SNMPv2Classic with the community-string-based Administrative Framework of SNMPv2C while retaining the bulk retrieval and improved error handling of SNMPv2Classic. It has these features:
–SNMPv2—Version 2 of the Simple Network Management Protocol, a Draft Internet Standard, defined in RFCs 1902 through 1907.
–SNMPv2C—The community-string-based Administrative Framework for SNMPv2, an Experimental Internet Protocol defined in RFC 1901.
•SNMPv3—Version 3 of the SNMP is an interoperable standards-based protocol defined in RFCs 2273 to 2275. SNMPv3 provides secure access to devices by authenticating and encrypting packets over the network and includes these security features:
–Message integrity—ensuring that a packet was not tampered with in transit
–Authentication—determining that the message is from a valid source
–Encryption—mixing the contents of a package to prevent it from being read by an unauthorized source.
Note To select encryption, enter the priv keyword. This keyword is available only when the crypto (encrypted) software image is installed.
Both SNMPv1 and SNMPv2C use a community-based form of security. The community of managers able to access the agent's MIB is defined by an IP address access control list and password.
SNMPv2C includes a bulk retrieval mechanism and more detailed error message reporting to management stations. The bulk retrieval mechanism retrieves tables and large quantities of information, minimizing the number of round-trips required. The SNMPv2C improved error-handling includes expanded error codes that distinguish different kinds of error conditions; these conditions are reported through a single error code in SNMPv1. Error return codes in SNMPv2C report the error type.
SNMPv3 provides for both security models and security levels. A security model is an authentication strategy set up for a user and the group within which the user resides. A security level is the permitted level of security within a security model. A combination of the security level and the security model determine which security mechanism is used when handling an SNMP packet. Available security models are SNMPv1, SNMPv2C, and SNMPv3.
The following table identifies the characteristics of the different combinations of security models and levels.
You must configure the SNMP agent to use the SNMP version supported by the management station. Because an agent can communicate with multiple managers, you can configure the software to support communications using SNMPv1, and SNMPv2C, and SNMPv3 protocols.
SNMP Manager Functions
The SNMP manager uses information in the MIB to perform the operations described in Table 52-1.
|
|
---|---|
get-request |
Retrieves a value from a specific variable. |
get-next-request |
Retrieves a value from a variable within a table.1 |
get-bulk-request2 |
Retrieves large blocks of data, such as multiple rows in a table, that would otherwise require the transmission of many small blocks of data. |
get-response |
Replies to a get-request, get-next-request, and set-request sent by an NMS. |
set-request |
Stores a value in a specific variable. |
trap |
An unsolicited message sent by an SNMP agent to an SNMP manager when some event has occurred. |
1 With this operation, an SNMP manager does not need to know the exact variable name. A sequential search is performed to find the needed variable from within a table. 2 The get-bulk command only works with SNMPv2 or later. |
SNMP Agent Functions
The SNMP agent responds to SNMP manager requests as follows:
•Get a MIB variable—The SNMP agent begins this function in response to a request from the NMS. The agent retrieves the value of the requested MIB variable and responds to the NMS with that value.
•Set a MIB variable—The SNMP agent begins this function in response to a message from the NMS. The SNMP agent changes the value of the MIB variable to the value requested by the NMS.
The SNMP agent also sends unsolicited trap messages to notify an NMS that a significant event has occurred on the agent. Examples of trap conditions include, but are not limited to, when a port or module goes up or down, when spanning-tree topology changes occur, and when authentication failures occur.
SNMP Community Strings
SNMP community strings authenticate access to MIB objects and function as embedded passwords. In order for the NMS to access the switch, the community string definitions on the NMS must match at least one of the three community string definitions on the switch.
A community string can have one of these attributes:
•Read-only (RO)—Gives read access to authorized management stations to all objects in the MIB except the community strings, but does not allow write access
•Read-write (RW)—Gives read and write access to authorized management stations to all objects in the MIB, but does not allow access to the community strings
•Read-write-all—Gives read and write access to authorized management stations to all objects in the MIB, including the community strings
Using SNMP to Access MIB Variables
An example of an NMS is the CiscoWorks network management software. CiscoWorks 2000 software uses the switch MIB variables to set device variables and to poll devices on the network for specific information. The results of a poll can be displayed as a graph and analyzed to troubleshoot internetworking problems, increase network performance, verify the configuration of devices, monitor traffic loads, and more.
As shown in Figure 52-1, the SNMP agent gathers data from the MIB. The agent can send traps, or notification of certain events, to the SNMP manager, which receives and processes the traps. Traps alert the SNMP manager to a condition on the network such as improper user authentication, restarts, link status (up or down), MAC address tracking, and so forth. The SNMP agent also responds to MIB-related queries sent by the SNMP manager in get-request, get-next-request, and set-request format.
Figure 52-1 SNMP Network
SNMP Notifications
SNMP allows the switch to send notifications to SNMP managers when particular events occur. SNMP notifications can be sent as traps or inform requests. In command syntax, unless there is an option in the command to select either traps or informs, the keyword traps refers to either traps or informs, or both. Use the snmp-server host command to specify whether to send SNMP notifications as traps or informs.
Note SNMPv1 does not support informs.
Traps are unreliable because the receiver does not send an acknowledgment when it receives a trap, and the sender cannot determine if the trap was received. When an SNMP manager receives an inform request, it acknowledges the message with an SNMP response protocol data unit (PDU). If the sender does not receive a response, the inform request can be sent again. Because they can be re-sent, informs are more likely than traps to reach their intended destination.
The characteristics that make informs more reliable than traps also consume more resources in the switch and in the network. Unlike a trap, which is discarded as soon as it is sent, an inform request is held in memory until a response is received or the request times out. Traps are sent only once, but an inform might be re-sent or retried several times. The retries increase traffic and contribute to a higher overhead on the network. Therefore, traps and informs require a trade-off between reliability and resources. If it is important that the SNMP manager receive every notification, use inform requests. If traffic on the network or memory in the switch is a concern and notification is not required, use traps.
Configuring SNMP
This section describes how to configure SNMP on your switch. It contains this configuration information:
•SNMP Configuration Guidelines
•Configuring Community Strings
•Configuring SNMP Groups and Users
•Configuring SNMP Notifications
•Setting the Agent Contact and Location Information
•Limiting TFTP Servers Used Through SNMP
Default SNMP Configuration
Table 52-2 shows the default SNMP configuration.
SNMP Configuration Guidelines
An SNMP group is a table that maps SNMP users to SNMP views. An SNMP user is a member of an SNMP group. An SNMP host is the recipient of an SNMP trap operation. An SNMP engine ID is a name for the local or remote SNMP engine.
When configuring SNMP, follow these guidelines:
•When configuring an SNMP group, do not specify a notify view. The snmp-server host global configuration command autogenerates a notify view for the user and then adds it to the group associated with that user. Modifying the group's notify view affects all users associated with that group. For information about when you should configure notify views, see the Cisco IOS Configuration Fundamentals Command Reference, Release 12.2.
•To configure a remote user, specify the IP address or port number for the remote SNMP agent of the device where the user resides.
•Before you configure remote users for a particular agent, configure the SNMP engine ID, using the snmp-server engineID global configuration with the remote option. The remote agent's SNMP engine ID and user password are used to compute the authentication and privacy digests. If you do not configure the remote engine ID first, the configuration command fails.
•When configuring SNMP informs, you need to configure the SNMP engine ID for the remote agent in the SNMP database before you can send proxy requests or informs to it.
•If a local user is not associated with a remote host, the switch does not send informs for the auth (authNoPriv) and the priv (authPriv) authentication levels.
•Changing the value of the SNMP engine ID has important side effects. A user's password (entered on the command line) is converted to an MD5 or SHA security digest based on the password and the local engine ID. The command-line password is then destroyed, as required by RFC 2274. Because of this deletion, if the value of the engine ID changes, the security digests of SNMPv3 users become invalid, and you need to reconfigure SNMP users by using the snmp-server user username global configuration command. Similar restrictions require the reconfiguration of community strings when the engine ID changes.
Disabling the SNMP Agent
To disable the SNMP agent, perform this task:
The no snmp-server global configuration command disables all running versions (Version 1, Version 2C, and Version 3) on the device. No specific IOS command exists to enable SNMP. The first snmp-server global configuration command that you enter enables all versions of SNMP.
Configuring Community Strings
You use the SNMP community string to define the relationship between the SNMP manager and the agent. The community string acts like a password to permit access to the agent on the switch. Optionally, you can specify one or more of these characteristics associated with the string:
•An access list of IP addresses of the SNMP managers that are permitted to use the community string to gain access to the agent
•A MIB view, which defines the subset of all MIB objects accessible to the given community
•Read and write or read-only permission for the MIB objects accessible to the community
To configure a community string on the switch, perform this task:
Note To disable access for an SNMP community, set the community string for that community to the null string (do not enter a value for the community string).
Note The snmp-server enable informs command is not supported. To enable the sending of SNMP inform notifications, use the snmp-server enable traps command combined with the snmp-server host host-addr informs command.
This example shows how to assign the string comaccess to SNMP, to allow read-only access, and to specify that IP access list 4 can use the community string to gain access to the switch SNMP agent:
Switch(config)# snmp-server community comaccess ro 4
Configuring SNMP Groups and Users
You can specify an identification name (engine ID) for the local or remote SNMP server engine on the switch. You can configure an SNMP server group that maps SNMP users to SNMP views, and you can add new users to the SNMP group.
To configure SNMP on the switch, perform this task:
Configuring SNMP Notifications
A trap manager is a management station that receives and processes traps. Traps are system alerts that the switch generates when certain events occur. By default, no trap manager is defined, and no traps are sent. Switches running IOS Cisco IOS Release 12.2(31)SG and later releases can have an unlimited number of trap managers.
Note Many commands use the word traps in the command syntax. Unless there is an option in the command to select either traps or informs, the keyword traps refers to either traps, informs, or both. Use the snmp-server host command to specify whether to send SNMP notifications as traps or informs.
Table 52-3 describes the supported switch traps (notification types). You can enable any or all of these traps and configure a trap manager to receive them.
You can use the snmp-server host global configuration command to a specific host to receive the notification types listed in Table 52-3.
To configure the switch to send traps or informs to a host, perform this task:
|
|
|
---|---|---|
Step 1 |
Switch# configure terminal |
Enters global configuration mode. |
Step 2 |
Switch(config)# snmp-server engineID remote ip-address engineid-string |
Specifies the engine ID for the remote host. |
Step 3 |
Switch(config)# snmp-server user username groupname remote host [udp-port port] {v1 | v2c | v3 [auth {md5 | sha} auth-password]} [encrypted] [access access-list] |
Configures an SNMP user to be associated with the remote host created in Step 2. Note You cannot configure a remote user for an address without first configuring the engine ID for the remote host. If you try to configure the user before configuring the remote engine ID, you receive an error message, and the command is not executed. |
Step 4 |
Switch(config)# snmp-server host host-addr [traps | informs] [version {1 | 2c | 3 [auth | noauth | priv]}] community-string [udp-port port] [notification-type] |
Specifies the recipient of an SNMP trap operation. •For host-addr, specify the name or Internet address of the host (the targeted recipient). •(Optional) Enter traps (the default) to send SNMP traps to the host. •(Optional) Enter informs to send SNMP informs to the host. •(Optional) Specify the SNMP version (1, 2c, or 3). SNMPv1 does not support informs. •(Optional) For Version 3, select authentication level auth, noauth, or priv. Note The priv keyword is available only when the crypto software image is installed. •For community-string, enter the password-like community string sent with the notification operation. •(Optional) For udp-port port, enter the remote device UDP port. •(Optional) For notification-type, use the keywords listed in Table 52-3. If no type is specified, all notifications are sent. |
Step 5 |
Switch(config)# snmp-server enable traps notification-types |
Enables the switch to send traps or informs and specify the type of notifications to be sent. For a list of notification types, see Table 52-3, or enter this: snmp-server enable traps ? To enable multiple types of traps, you must enter a separate snmp-server enable traps command for each trap type. |
Step 6 |
Switch(config)# snmp-server
trap-source interface-id
|
(Optional) Specifies the source interface, which provides the IP address for the trap message. This command also sets the source IP address for informs. |
Step 7 |
Switch(config)# snmp-server
queue-length length
|
(Optional) Establishes the message queue length for each trap host. The range is 1 to 1000; the default is 10. |
Step 8 |
Switch(config)# snmp-server
trap-timeout seconds
|
(Optional) Defines how often to resend trap messages. The range is 1 to 1000; the default is 30 seconds. |
Step 9 |
Switch(config)# end |
Returns to privileged EXEC mode. |
Step 10 |
Switch# show running-config |
Verifies your entries. |
Step 11 |
Switch# copy running-config startup-config |
(Optional) Saves your entries in the configuration file. |
The snmp-server host command specifies which hosts receive the notifications. The
snmp-server enable trap command globally enables the mechanism for the specified notification (for traps and informs). To enable a host to receive an inform, you must configure an
snmp-server host informs command for the host and globally enable informs by using the
snmp-server enable traps command.
To remove the specified host from receiving traps, use the no snmp-server host host global configuration command. The no snmp-server host command with no keywords disables traps, but not informs, to the host. To disable informs, use the no snmp-server host informs global configuration command. To disable a specific trap type, use the no snmp-server enable traps notification-types global configuration command.
Setting the Agent Contact and Location Information
To set the system contact and location of the SNMP agent so that these descriptions can be accessed through the configuration file, perform this task:
Limiting TFTP Servers Used Through SNMP
To limit the TFTP servers used for saving and loading configuration files through SNMP to the servers specified in an access list, perform this task:
SNMP Examples
This example shows how to enable all versions of SNMP. The configuration permits any SNMP manager to access all objects with read-only permissions using the community string public. This configuration does not cause the switch to send any traps.
Switch(config)# snmp-server community public
This example shows how to permit any SNMP manager to access all objects with read-only permission using the community string public. The switch also sends VTP traps to the hosts 192.180.1.111 and 192.180.1.33 using SNMPv1 and to the host 192.180.1.27 using SNMPv2C. The community string public is sent with the traps.
Switch(config)# snmp-server community public
Switch(config)# snmp-server enable traps vtp
Switch(config)# snmp-server host 192.180.1.27 version 2c public
Switch(config)# snmp-server host 192.180.1.111 version 1 public
Switch(config)# snmp-server host 192.180.1.33 public
This example shows how to allow read-only access for all objects to members of access list 4 that use the comaccess community string. No other SNMP managers have access to any objects. SNMP Authentication Failure traps are sent by SNMPv2C to the host cisco.com using the community string public.
Switch(config)# snmp-server community comaccess ro 4
Switch(config)# snmp-server enable traps snmp authentication
Switch(config)# snmp-server host cisco.com version 2c public
This example shows how to send Entity MIB traps to the host cisco.com. The community string is restricted. The first line enables the switch to send Entity MIB traps in addition to any traps previously enabled. The second line specifies the destination of these traps and overwrites any previous snmp-server host commands for the host cisco.com.
Switch(config)# snmp-server enable traps entity
Switch(config)# snmp-server host cisco.com restricted entity
This example shows how to enable the switch to send all traps to the host myhost.cisco.com using the community string public:
Switch(config)# snmp-server enable traps
Switch(config)# snmp-server host myhost.cisco.com public
This example shows how to associate a user with a remote host and to send auth (authNoPriv) authentication-level informs when the user enters global configuration mode:
Switch(config)# snmp-server engineID remote 192.180.1.27 00000063000100a1c0b4011b
Switch(config)# snmp-server group authgroup v3 auth
Switch(config)# snmp-server user authuser authgroup remote 192.180.1.27 v3 auth md5 mypassword
Switch(config)# snmp-server user authuser authgroup v3 auth md5 mypassword
Switch(config)# snmp-server host 192.180.1.27 informs version 3 auth authuser config
Switch(config)# snmp-server enable traps
Switch(config)# snmp-server inform retries 0
Displaying SNMP Status
To display SNMP input and output statistics, including the number of illegal community string entries, errors, and requested variables, use the show snmp privileged EXEC command.You can also use the other privileged EXEC commands in Table 52-4 to display SNMP information. For information about the fields in the output displays, see the Cisco IOS Configuration Fundamentals Command Reference, Release 12.4.
Note The snmp-server enable informs command is not supported. To enable the sending of SNMP inform notifications, use the snmp-server enable traps command combined with the
snmp-server host host-addr informs command.