Technical Specifications
This appendix contains these topics:
Environmental Specifications
1 |
23 to 113°F (–5 to 45°C) up to 5,000 ft (1500 m) 23 to 104°F (–5 to 40°C) up to 10,000 ft (3000 m) |
Power Requirements |
|||
Operating temperature |
23 to 113°F (–5 to 45°C) |
||
Storage temperature |
–40 to 158°F (–40 to 70°C) |
||
Relative humidity |
10-95% (non-condensing) |
||
Altitude |
Up to 10,000 ft (3,000 m) |
||
Weight |
PWR-C2-1025WAC: 3.4 lb (1.6 kg) |
||
Dimensions |
PWR-C2-1025WAC: 1.58 x 11.72 x 3.75 in. (3.5 x 29.8 x 9.53 cm)
|
Specifications for the Catalyst 6800IA Switches
Physical Dimensions |
|||
Weight |
11.3 lb (5.1 kg)
|
||
Dimensions (H x D x W) |
1.75 x 16.05 x 17.5 in. (4.45 x 40.77 x 44.5 cm) |
Power Requirements |
|
Maximum output power |
1025 W |
Input voltage and Frequency |
1025 W, 115-240 VAC, (autoranging) 50-60 Hz |
Input current |
12–6 A |
Output ratings |
+12 V @ 20.83 A, –54 V@14.6 A |
Total input BTU2 |
3801 BTUs per hour, 1114 W |
Total output BTU |
3497 BTUs per hour, 1025 W |
The total input and total output BTU ratings refer to input power to the power supply and output power to the switch. The BTU ratings are based on 115 VAC for the 1025-W power supply.
9 to 4 A, 50 to 60 Hz, 100 to 240 VAC (autoranging) |
|
+12 V @ 4 A, –53 V @ 15 A |
|
149 W, 508 BTUs per hour |
|
0.89 KVA |
|
30 W-per-port maximum, 740-W switch maximum |
|
12.9 lb (5.8 kg) |
|
1 to 0.5 A, 50 to 60 Hz, 100 to 240 VAC (autoranging) |
|
+12 V @ 4 A, –53 V @ 8 A |
|
Power consumption 5 |
47 W, 161 BTUs per hour |
Power rating6 |
0.049 KVA |
Weight |
9.6 lb (4.3 kg) |
1.75 x 11 x 17.50 in. (4.45 x 27.94 x 44.5 cm) |