Server Specifications

This appendix contains information about the server specifications:

Server Specifications

This appendix lists the physical, environmental, and power specifications for the server.

Physical Specifications

The following figure shows the height, width, and depth of the chassis as measured to different locations.

The following table lists additional physical specifications for the server versions.

Table 1. Physical Specifications

Description

Specification

Server weight

  • SFF 12-drive server:

    • Maximum, fully configured with rail kit: 49.2 lb (20.28 kg)

    • Minimum, empty chassis, no rail kit: 35.7 lb (16.2 kg)

  • SFF 24-drive server:

    • Maximum, fully configured with rail kit: 61.7 lb (26.67 kg)

    • Minimum, empty chassis, no rail kit: 33.14 lb (15.03 kg)

  • LFF 12-drive server:

    • Maximum, fully configured with rail kit: 66.75 lb (28.0 kg)

    • Minimum, empty chassis, no rail kit: 39.13 lb (17.75 kg)

Front Clearance

3 in. (76 mm)

Side Clearance

1 in. (25 mm)

Rear Clearance

6 in. (152 mm)

Environmental Specifications

As a Class A2 product, the server has the following environmental specifications.

Table 2. Environmental Specifications

Description

Specification

Temperature, Operating

Dry bulb temperature of 10°C to 35°C (50°F to 95°F)

Maximum temperature change of 20°C (36°F) per hour

(a temperature change within a specified period of time and not a rate of change)

Humidity condition: Uncontrolled, not to exceed 50% RH starting condition

Derate the maximum temperature by 1°C (33.8°F) per every 305 meters of altitude above 900m

Temperature, Extended Operating

5°C to 40°C (41°F to 104°F) with no direct sunlight

Humidity condition: Uncontrolled, not to exceed 50% RH starting condition

Derate the maximum temperature by 1°C (33.8°F) per every 305 meters of altitude above 900m

Temperature, non-operating

(when the server is stored or transported)

Dry bulb temperature of 40 °C to 65 °C (-40°F to 149 °F)

Humidity (RH), operating

10% to 90% and 28°C (82.4°F) maximum dew-point temperature, non-condensing environment

Minimum to be higher (more moisture) of -12 ˚C (10.4 ˚F) dew point or 8% relative humidity

Maximum to be 24 ˚C (75.2 ˚F) dew point or 90% relative humidity

Humidity (RH), non-operating

(when the server is stored or transported)

5% to 93% relative humidity, non-condensing, with a maximum wet bulb temperature of 28 °C across the 20 °C to 40 °C dry bulb range.

Altitude, operating

A maximum elevation of 3050 meters (10,006 feet)

Altitude, non-operating

(when the server is stored or transported)

An elevation of 0 to 12,000 meters (39,370 feet)

Maximum Operating Duration

Unlimited

Sound power level

Measure A-weighted per ISO7779 LwAd (Bels)

Operation at 73°F (23°C)

5.5

Sound pressure level

Measure A-weighted per ISO7779 LpAm (dBA)

Operation at 73°F (23°C)

40

Power Specifications


Note


Do not mix power supply types or wattages in the server. Both power supplies must be identical.

You can get more specific power information for your exact server configuration by using the Cisco UCS Power Calculator:

http://ucspowercalc.cisco.com

The power specifications for the supported power supply options are listed in the following sections.

1050 W AC Power Supply

This section lists the specifications for each 1050 W AC power supply (Cisco part number UCSC-PSU1-1050W).

Table 3. 1050 W AC Specifications

Description

Specification

AC Input Voltage

Nominal range: 100–120 VAC, 200–240 VAC

(Range: 90–132 VAC, 180–264 VAC)

AC Input Frequency

Nominal range: 50 to 60Hz

(Range: 47–63 Hz)

Maximum AC Input current

12.5 A at 100 VAC

6.0 A at 208 VAC

Maximum input volt-amperes

1250 VA at 100 VAC

Maximum inrush current

15 A (sub-cycle duration)

Maximum hold-up time

12 ms at 1050 W

Maximum output power per PSU

800 W at 100–120 VAC

1050 W at 200–240 VAC

Power supply output voltage

12 VDC

Power supply standby voltage

12 VDC

Efficiency rating

Climate Savers Platinum Efficiency (80Plus Platinum certified)

Form factor

RSP2

Input connector

IEC320 C14

1050 W DC Power Supply

This section lists the specifications for each 1050 W DC power supply (Cisco part number UCSC-PSUV2-1050DC).

Table 4. 1050 W DC Specifications

Description

Specification

DC Input Voltage

Nominal range: -48 to -60 VDC

(Range: -40 to -72 VDC)

Maximum DC input current

N32 A at -40 VDC

Maximum input wattage

1234 W

Maximum inrush current

35 A (sub-cycle duration)

Maximum hold-up time

5 ms at 100% load (1050 W main and 36 W standby)

Maximum output power per PSU

1050 W on 12 VDC main power

36 W on 12 VDC standby power

Power supply output voltage

12 VDC

Power supply standby voltage

12 VDC

Efficiency rating

≥ 92% at 50% load

Form factor

RSP2

Input connector

Fixed 3-wire block

1200 W AC Power Supply

This section lists the specifications for each 1200 W AC power supply (Cisco part number UCSC-PSU1-1200W-D).

Table 5. 1200 W AC Specifications

Description

Specification

AC input voltage

Range: 100–230 VAC

AC input frequency

Range: 50 to 60Hz

Maximum AC input current

12.97 A at 100 VAC

Maximum input volt-amperes

1345 VA at 208 VAC

Maximum inrush current

20 A

Maximum hold-up time

12 ms at 1200 W

Maximum output power per PSU

1100 W at 100–120 VAC

1200 W at 208–230 VAC

Power supply output voltage

12 VDC

Power supply standby voltage

12 VDC

Efficiency rating

Climate Savers Platinum Efficiency (80Plus Titanium certified)

Form factor

RSP2

Input connector

IEC320 C14

1600 W AC Power Supply

This section lists the specifications for each 1600 W AC power supply (Cisco part number UCSC-PSU1-1600W).

Table 6. 1600 W AC Specifications

Description

Specification

AC Input Voltage

Nominal range: 200–240 VAC

(Range: 180–264 VAC)

AC Input Frequency

Nominal range: 50 to 60Hz

(Range: 47–63 Hz)

Maximum AC Input current

9.5 A at 200 VAC

Maximum input volt-amperes

1250 VA at 200 VAC

Maximum inrush current

30 A at 35° C

Maximum hold-up time

80 ms at 1600 W

Maximum output power per PSU

1600 W at 200–240 VAC

Power supply output voltage

12 VDC

Power supply standby voltage

12 VDC

Efficiency rating

Climate Savers Platinum Efficiency (80Plus Platinum certified)

Form factor

RSP2

Input connector

IEC320 C14

2300 W AC Power Supply


Note


For the 80PLUS platinum certification documented in the following table, you can find test results at https://www.clearesult.com/80plus/.


This section lists the specifications for each 2300 W AC power supply (Cisco part number UCSC-PSU1-2300).

Parameter

Specification

Input Connector

IEC320 C20

Input Voltage Range (V rms)

100 to 240

Maximum Allowable Input Voltage Range (V rms)

90 to 264

Frequency Range (Hz)

50 to 60

Maximum Allowable Frequency Range (Hz)

47 to 63

Maximum Rated Output (W)

Limited to 800W when operating at low-line input voltage, 100-127 V

2300

Maximum Rated Standby Output (W)

36

Nominal Input Voltage (V rms)

100

120

208

230

Nominal Input Current (A rms)

13

11

12

10.8

Maximum Input at Nominal Input Voltage (W)

1338

1330

2490

2480

Maximum Input at Nominal Input Voltage (VA)

1351

1343

2515

2505

Maximum Rated Efficiency (%)

Minimum rating required to achieve 80PLUS platinum certification.

92

92

93

93

Maximum Rated Power Factor

Minimum rating required to achieve 80PLUS platinum certification.

0.99

0.99

0.97

0.97

Maximum Inrush Current (peak A)

30

Maximum Inrush Current (ms)

0.2

Maximum Ride-Through Time

Time output voltage remains within regulation limits at 100% load, during input voltage dropout

12

Power Cord Specifications

Each power supply in the server has a power cord. Standard power cords or jumper power cords are available for connection to the server. The shorter jumper power cords, for use in racks, are available as an optional alternative to the standard power cords.


Note


Only the approved power cords or jumper power cords listed below are supported.


Table 7. Supported Power Cords

Description

Length (Feet)

Length (Meters)

CAB-48DC-40A-8AWG

DC power cord, -48 VDC, 40 A, 8 AWG

Three-socket Mini-Fit connector to three-wire

11.7

3.5

CAB-C13-C14-AC

AC power cord, 10 A; C13 to C14, recessed receptacle

9.8

3.0

CAB-250V-10A-AR

AC power cord, 250 V, 10 A

Argentina

8.2

2.5

CAB-C13-C14-2M-JP

AC Power Cord, C13 to C14

Japan PSE Mark

6.6

2.0

CAB-9K10A-EU

AC Power Cord, 250 V, 10 A; CEE 7/7 Plug

Europe

8.2

2.5

CAB-250V-10A-IS

AC Power Cord, 250 V, 10 A

Israel

8.2

2.5

CAB-250V-10A-CN

AC power cord, 250 V, 10 A

PR China

8.2

2.5

CAB-ACTW

AC power cord, 250 V, 10 A

Taiwan

7.5

2.3

CAB-C13-CBN

AC cabinet jumper power cord, 250, 10 A,

C13 to C14

2.2

0.68

CAB-C13-C14-2M

AC cabinet jumper power cord, 250 V, 10 A,

C13 to C14

6.6

2.0

CAB-9K10A-AU

AC power cord, 250 V, 10 A, 3112 plug,

Australia

8.2

2.5

CAB-N5K6A-NA

AC power cord, 200/240 V, 6 A,

North America

8.2

2.5

CAB-250V-10A-ID

AC power Cord, 250 V, 10 A,

India

8.2

2.5

CAB-9K10A-SW

AC power cord, 250 V, 10 A, MP232 plug

Switzerland

8.2

2.5

CAB-250V-10A-BR

AC power Cord, 250 V, 10 A

Brazil

8.2

2.5

CAB-9K10A-UK

AC power cord, 250 V, 10 A (13 A fuse), BS1363 plug

United Kingdom

8.2

2.5

CAB-9K12A-NA

AC power cord, 125 V, 13 A, NEMA 5-15 plug

North America

8.2

2.5

CAB-AC-L620-C13

AC power cord, NEMA L6-20 to C13 connectors

6.6

2.0

CAB-9K10A-IT

AC power cord, 250 V, 10 A, CEI 23-16/VII plug

Italy

8.2

2.5

R2XX-DMYMPWRCORD

No power cord; PID option for ordering server with no power cord

NA

NA