Cisco UCS Faults
This chapter provides information about the faults that may be raised in a Cisco UCS instance.
fltFabricComputeSlotEpMisplacedInChassisSlot
Fault Code: F0156
Message
Server, vendor([vendor]), model([model]), serial([serial]) in slot [chassisId]/[slotId] presence: [presence]
Explanation
This fault typically occurs when Cisco UCS Manager detects a server in a chassis slot that does not match what was previously equipped in the slot.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the previous server was intentionally removed and a new one was inserted, reacknowledge the server.
Step 2 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFabricComputeSlotEpMisplacedInChassisSlot
moClass: fabric:ComputeSlotEp
Affected MO: fabric/server/chassis-[chassisId]/slot-[slotId]
fltFabricComputeSlotEpServerIdentificationProblem
Fault Code: F0157
Message
Problem identifying server in slot [chassisId]/[slotId]
Explanation
This fault typically occurs when Cisco UCS Manager encountered a problem identifying the server in a chassis slot.
Recommended Action
If you see this fault, take the following actions:
Step 1 Remove and reinsert the server.
Step 2 Reacknowledge the server.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: server-identification-problem
mibFaultName: fltFabricComputeSlotEpServerIdentificationProblem
moClass: fabric:ComputeSlotEp
Affected MO: fabric/server/chassis-[chassisId]/slot-[slotId]
fltVnicEtherConfig-failed
Fault Code: F0169
Message
Eth vNIC [name], service profile [name] failed to apply configuration
Explanation
This fault typically occurs when Cisco UCS Manager could not place the vNIC on the vCon.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the server was successfully discovered.
Step 2 Verify that the correct type of adapters are installed on the server.
Step 3 Confirm that the vCon assignment is correct.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: configuration-failed
mibFaultName: fltVnicEtherConfigFailed
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]
fltVnicFcConfig-failed
Fault Code: F0170
Message
FC vHBA [name], service profile [name] failed to apply configuration
Explanation
This fault typically occurs when Cisco UCS Manager could not place the vHBA on the vCon.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the server was successfully discovered.
Step 2 Verify that the correct type of adapters are installed on the server.
Step 3 Confirm that the vCon assignment is correct.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: configuration-failed
mibFaultName: fltVnicFcConfigFailed
Affected MO: org-[name]/ls-[name]/fc-[name]
Affected MO: org-[name]/san-conn-pol-[name]/fc-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/fc-[name]
fltProcessorUnitInoperable
Fault Code: F0174
Message
Processor [id] on server [chassisId]/[slotId] operability: [operability]Processor [id] on rack server [id] operability: [operability]Processor [id] on server [chassisId]/[slotId]/[serverInstanceId] operability: [operability]
Explanation
This fault occurs in the unlikely event that processor is inoperable.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the fault occurs on a blade server processor, remove the server from the chassis and then reinsert it.
Step 2 In Cisco UCS Manager, decommission and then recommission the server.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inoperable
mibFaultName: fltProcessorUnitInoperable
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/cpu-[id]
Affected MO: sys/rack-unit-[id]/board/cpu-[id]
fltProcessorUnitThermalNonCritical
Fault Code: F0175
Message
Processor [id] on server [chassisId]/[slotId] temperature: [thermal]Processor [id] on server [id] temperature: [thermal]Processor [id] on server [chassisId]/[slotId]/[serverInstanceId] temperature: [thermal]
Explanation
This fault occurs when the processor temperature on a blade or rack server exceeds a non-critical threshold value, but is still below the critical threshold. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco UCS equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco UCS equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
- If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the server.
Step 2 Review the Cisco UCS Site Preparation Guide to ensure the servers have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco UCS chassis or rack server are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Use the Cisco UCS power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 8 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltProcessorUnitThermalNonCritical
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/cpu-[id]
Affected MO: sys/rack-unit-[id]/board/cpu-[id]
fltProcessorUnitThermalThresholdCritical
Fault Code: F0176
Message
Processor [id] on server [chassisId]/[slotId] temperature: [thermal]Processor [id] on server [id] temperature: [thermal]Processor [id] on server [chassisId]/[slotId]/[serverInstanceId] temperature: [thermal]
Explanation
This fault occurs when the processor temperature on a blade or rack server exceeds a critical threshold value. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco UCS equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco UCS equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
- If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the server.
Step 2 Review the Cisco UCS Site Preparation Guide to ensure the servers have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco UCS chassis or rack server are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Use the Cisco UCS power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 8 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltProcessorUnitThermalThresholdCritical
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/cpu-[id]
Affected MO: sys/rack-unit-[id]/board/cpu-[id]
fltProcessorUnitThermalThresholdNonRecoverable
Fault Code: F0177
Message
Processor [id] on server [chassisId]/[slotId] temperature: [thermal]Processor [id] on server [id] temperature: [thermal]Processor [id] on server [chassisId]/[slotId]/[serverInstanceId] temperature: [thermal]
Explanation
This fault occurs when the processor temperature on a blade or rack server has been out of the operating range, and the issue is not recoverable. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco UCS equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco UCS equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
- If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the server.
Step 2 Review the Cisco UCS Site Preparation Guide to ensure the servers have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco UCS chassis or rack server are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Use the Cisco UCS power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 8 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltProcessorUnitThermalThresholdNonRecoverable
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/cpu-[id]
Affected MO: sys/rack-unit-[id]/board/cpu-[id]
fltProcessorUnitVoltageThresholdNonCritical
Fault Code: F0178
Message
Processor [id] on server [chassisId]/[slotId] voltage: [voltage]Processor [id] on server [id] voltage: [voltage]Processor [id] on server [chassisId]/[slotId]/[serverInstanceId] voltage: [voltage]
Explanation
This fault occurs when the processor voltage is out of normal operating range, but hasn’t yet reached a critical stage. Normally the processor recovers itself from this situation
Recommended Action
If you see this fault, take the following actions:
Step 1 Monitor the processor for further degradation.
Step 2 If the fault occurs on a blade server processor, remove the server from the chassis and then reinsert it.
Step 3 In Cisco UCS Manager, decommission and then recommission the server.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltProcessorUnitVoltageThresholdNonCritical
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/cpu-[id]
Affected MO: sys/rack-unit-[id]/board/cpu-[id]
fltProcessorUnitVoltageThresholdCritical
Fault Code: F0179
Message
Processor [id] on server [chassisId]/[slotId] voltage: [voltage]Processor [id] on server [id] voltage: [voltage]Processor [id] on server [chassisId]/[slotId]/[serverInstanceId] voltage: [voltage]
Explanation
This fault occurs when the processor voltage has exceeded the specified hardware voltage rating.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the fault occurs on a blade server processor, remove the server from the chassis and then reinsert it.
Step 2 In Cisco UCS Manager, decommission and then recommission the server.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltProcessorUnitVoltageThresholdCritical
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/cpu-[id]
Affected MO: sys/rack-unit-[id]/board/cpu-[id]
fltProcessorUnitVoltageThresholdNonRecoverable
Fault Code: F0180
Message
Processor [id] on server [chassisId]/[slotId] voltage: [voltage]Processor [id] on server [id] voltage: [voltage]Processor [id] on server [chassisId]/[slotId]/[serverInstanceId] voltage: [voltage]
Explanation
This fault occurs when the processor voltage has exceeded the specified hardware voltage rating and may cause processor hardware damage or jeopardy.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the fault occurs on a blade server processor, remove the server from the chassis and then reinsert it.
Step 2 In Cisco UCS Manager, decommission and then recommission the server.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltProcessorUnitVoltageThresholdNonRecoverable
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/cpu-[id]
Affected MO: sys/rack-unit-[id]/board/cpu-[id]
fltStorageLocalDiskInoperable
Fault Code: F0181
Message
Local disk [id] on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]Local disk [id] on server [id] operability: [operability]. Reason: [operQualifierReason]Local disk [id] on storage enclosure [id] operability: [operability]. Reason: [operQualifierReason]Local disk [id] on chassis [id] operability: [operability]. Reason: [operQualifierReason]
Explanation
This fault occurs when the local disk has become inoperable.
Recommended Action
If you see this fault, take the following actions:
Step 1 Insert the disk in a supported slot.
Step 2 Remove and reinsert the local disk.
Step 3 Replace the disk, if an additional disk is available.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inoperable
mibFaultName: fltStorageLocalDiskInoperable
moClass: storage:LocalDisk
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]
fltStorageItemCapacityExceeded
Fault Code: F0182
Message
Disk usage for partition [name] on fabric interconnect [id] exceeded 70%
Explanation
This fault occurs when the partition disk usage exceeds 70% but is less than 90%.
Recommended Action
If you see this fault, take the following actions:
Step 1 Reduce the partition disk usage to less than 70% by deleting unused and unnecessary files.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltStorageItemCapacityExceeded
Affected MO: sys/switch-[id]/stor-part-[name]
fltStorageItemCapacityWarning
Fault Code: F0183
Message
Disk usage for partition [name] on fabric interconnect [id] exceeded 90%
Explanation
This fault occurs when the partition disk usage exceeds 90%.
Recommended Action
If you see this fault, take the following actions:
Step 1 Reduce the partition disk usage to less than 90% by deleting unused and unnecessary files.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltStorageItemCapacityWarning
Affected MO: sys/switch-[id]/stor-part-[name]
fltMemoryUnitDegraded
Fault Code: F0184
Message
DIMM [location] on server [chassisId]/[slotId] operability: [operability]DIMM [location] on server [id] operability: [operability]DIMM [location] on server [chassisId]/[slotId]/[serverInstanceId] operability: [operability]
Explanation
This fault occurs when a DIMM is in a degraded operability state. This state typically occurs when an excessive number of correctable ECC errors are reported on the DIMM by the server BIOS.
Recommended Action
If you see this fault, take the following actions:
Step 1 Monitor the error statistics on the degraded DIMM through Cisco UCS Manager. If the high number of errors persists, there is a high possibility of the DIMM becoming inoperable.
Step 2 If the DIMM becomes inoperable, replace the DIMM.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-degraded
mibFaultName: fltMemoryUnitDegraded
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]/mem-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/memarray-[id]/mem-[id]
Affected MO: sys/rack-unit-[id]/board/memarray-[id]/mem-[id]
fltMemoryUnitInoperable
Fault Code: F0185
Message
DIMM [location] on server [chassisId]/[slotId] operability: [operability]DIMM [location] on server [id] operability: [operability]DIMM [location] on server [chassisId]/[slotId]/[serverInstanceId] operability: [operability]
Explanation
This fault typically occurs because an above threshold number of correctable or uncorrectable errors has occurred on a DIMM. The DIMM may be inoperable.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the SEL is enabled, review the SEL statistics on the DIMM to determine which threshold was crossed.
Step 2 If necessary, replace the DIMM.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inoperable
mibFaultName: fltMemoryUnitInoperable
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]/mem-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/memarray-[id]/mem-[id]
Affected MO: sys/rack-unit-[id]/board/memarray-[id]/mem-[id]
fltMemoryUnitThermalThresholdNonCritical
Fault Code: F0186
Message
DIMM [location] on server [chassisId]/[slotId] temperature: [thermal]DIMM [location] on server [id] temperature: [thermal]DIMM [location] on server [chassisId]/[slotId]/[serverInstanceId] temperature: [thermal]
Explanation
This fault occurs when the temperature of a memory unit on a blade or rack server exceeds a non-critical threshold value, but is still below the critical threshold. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco UCS equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco UCS equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
- If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the server.
Step 2 Review the Cisco UCS Site Preparation Guide to ensure the servers have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco UCS chassis or rack server are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Use the Cisco UCS power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 8 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltMemoryUnitThermalThresholdNonCritical
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]/mem-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/memarray-[id]/mem-[id]
Affected MO: sys/rack-unit-[id]/board/memarray-[id]/mem-[id]
fltMemoryUnitThermalThresholdCritical
Fault Code: F0187
Message
DIMM [location] on server [chassisId]/[slotId] temperature: [thermal]DIMM [location] on server [id] temperature: [thermal]DIMM [location] on server [chassisId]/[slotId]/[serverInstanceId] temperature: [thermal]
Explanation
This fault occurs when the temperature of a memory unit on a blade or rack server exceeds a critical threshold value. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco UCS equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco UCS equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
- If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the server.
Step 2 Review the Cisco UCS Site Preparation Guide to ensure the servers have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco UCS chassis or rack server are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Use the Cisco UCS power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 8 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltMemoryUnitThermalThresholdCritical
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]/mem-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/memarray-[id]/mem-[id]
Affected MO: sys/rack-unit-[id]/board/memarray-[id]/mem-[id]
fltMemoryUnitThermalThresholdNonRecoverable
Fault Code: F0188
Message
DIMM [location] on server [chassisId]/[slotId] temperature: [thermal]DIMM [location] on server [id] temperature: [thermal]DIMM [location] on server [chassisId]/[slotId]/[serverInstanceId] temperature: [thermal]
Explanation
This fault occurs when the temperature of a memory unit on a blade or rack server has been out of the operating range, and the issue is not recoverable.Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco UCS equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco UCS equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
- If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the server.
Step 2 Review the Cisco UCS Site Preparation Guide to ensure the servers have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco UCS chassis or rack server are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Use the Cisco UCS power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 8 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltMemoryUnitThermalThresholdNonRecoverable
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]/mem-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/memarray-[id]/mem-[id]
Affected MO: sys/rack-unit-[id]/board/memarray-[id]/mem-[id]
fltMemoryArrayVoltageThresholdNonCritical
Fault Code: F0189
Message
Memory array [id] on server [chassisId]/[slotId] voltage: [voltage]Memory array [id] on server [id] voltage: [voltage]Memory array [id] on server [chassisId]/[slotId]/[serverInstanceId] voltage: [voltage]
Explanation
This fault occurs when the memory array voltage is out of normal operating range, but hasn’t yet reached a critical stage. Typically the memory array recovers itself from this situation.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the SEL is enabled, look at the SEL statistics on the DIMM to determine which threshold was crossed.
Step 2 Monitor the memory array for further degradation.
Step 3 If the fault occurs on a blade server memory array, remove the blade and re-insert into the chassis.
Step 4 In Cisco UCS Manager, decommission and recommission the server.
Step 5 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltMemoryArrayVoltageThresholdNonCritical
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/memarray-[id]
Affected MO: sys/rack-unit-[id]/board/memarray-[id]
fltMemoryArrayVoltageThresholdCritical
Fault Code: F0190
Message
Memory array [id] on server [chassisId]/[slotId] voltage: [voltage]Memory array [id] on server [id] voltage: [voltage]Memory array [id] on server [chassisId]/[slotId]/[serverInstanceId] voltage: [voltage]
Explanation
This fault occurs when the memory array voltage exceeds the specified hardware voltage rating
Recommended Action
If you see this fault, take the following actions:
Step 1 If the SEL is enabled, look at the SEL statistics on the DIMM to determine which threshold was crossed.
Step 2 Monitor the memory array for further degradation.
Step 3 If the fault occurs on a blade server memory array, remove the blade and re-insert into the chassis.
Step 4 In Cisco UCS Manager, decommission and recommission the server.
Step 5 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltMemoryArrayVoltageThresholdCritical
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/memarray-[id]
Affected MO: sys/rack-unit-[id]/board/memarray-[id]
fltMemoryArrayVoltageThresholdNonRecoverable
Fault Code: F0191
Message
Memory array [id] on server [chassisId]/[slotId] voltage: [voltage]Memory array [id] on server [id] voltage: [voltage]Memory array [id] on server [chassisId]/[slotId]/[serverInstanceId] voltage: [voltage]
Explanation
This fault occurs when the memory array voltage exceeded the specified hardware voltage rating and potentially memory hardware may be in damage or jeopardy
Recommended Action
If you see this fault, take the following actions:
Step 1 If the SEL is enabled, review the SEL statistics on the DIMM to determine which threshold was crossed.
Step 2 Monitor the memory array for further degradation.
Step 3 If the fault occurs on a blade server memory array, remove the server from the chassis and re-insert it.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltMemoryArrayVoltageThresholdNonRecoverable
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/memarray-[id]
Affected MO: sys/rack-unit-[id]/board/memarray-[id]
fltAdaptorUnitUnidentifiable-fru
Fault Code: F0200
Message
Adapter [id] in server [id] has unidentified FRU.Adapter [id] in server [chassisId]/[slotId] has unidentified FRU.Adapter [id] in server [chassisId]/[slotId]/[serverInstanceId] has unidentified FRU
Explanation
This fault typically occurs because Cisco UCS Manager has detected an unsupported adapter. For example, the model, vendor, or revision is not recognized.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that a supported adapter is installed.
Step 2 Verify that the capability catalog in Cisco UCS Manager is up to date. If necessary, update the catalog.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: unidentifiable-fru
mibFaultName: fltAdaptorUnitUnidentifiableFru
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]
fltAdaptorUnitMissing
Fault Code: F0203
Message
Adapter [id] in server [id] presence: [presence]Adapter [id] in server [chassisId]/[slotId] presence: [presence]Adapter [id] in server [chassisId]/[slotId]/[serverInstanceId] presence: [presence]
Explanation
The adaptor is missing. Cisco UCS Manager raises this fault when any of the following scenarios occur:
- The endpoint reports there is no adapter in the adaptor slot.
- The endpoint cannot detect or communicate with the adapter in the adaptor slot.
Recommended Action
If you see this fault, take the following actions:
Step 1 Make sure an adapter is inserted in the adaptor slot in the server.
Step 2 Check whether the adaptor is connected and configured properly and is running the recommended firmware version.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltAdaptorUnitMissing
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]
fltAdaptorUnitAdaptorReachability
Fault Code: F0206
Message
Adapter [id]/[id] is unreachableAdapter [chassisId]/[slotId]/[id] is unreachable
Explanation
Cisco UCS Manager cannot access the adapter. This fault typically occurs as a result of one of the following issues:
- The server does not have sufficient power.
- The I/O module is not functional.
- The adapter firmware has failed.
- The adapter is not functional
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the POST results for the server. In Cisco UCS Manager GUI, you can access the POST results from the General tab for the server. In Cisco UCS Manager CLI, you can access the POST results through the show post command under the scope for the server.
Step 2 In Cisco UCS Manager, check the power state of the server.
Step 3 Verify that the physical server has the same power state.
Step 4 If the server is off, turn the server on.
Step 5 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: connectivity-problem
mibFaultName: fltAdaptorUnitAdaptorReachability
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]
fltAdaptorHostIfLink-down
Fault Code: F0207
Message
Adapter [transport] host interface [id]/[id]/[id] link state: [linkState]Adapter [transport] host interface [chassisId]/[slotId]/[id]/[id] link state: [linkState]Adapter [transport] host interface [chassisId]/[slotId]/[serverInstanceId] link state: [linkState]
Explanation
This fault typically occurs as a result of one of the following issues:
- The fabric interconnect is in End-Host mode, and all uplink ports failed.
- The server port to which the adapter is pinned failed.
- A transient error caused the link to fail.
Recommended Action
If you see this fault, take the following actions:
Step 1 If an associated port is disabled, enable the port.
Step 2 Reacknowledge the server with the adapter that has the failed link.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltAdaptorHostIfLinkDown
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-scsi-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-scsi-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-scsi-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]
fltAdaptorExtIfLink-down
Fault Code: F0209
Message
Adapter uplink interface [id]/[id]/[id] link state: [linkState]. Please verify connectivity to Fabric Interconnect. Acknowledging FEX might be required.Adapter uplink interface [chassisId]/[slotId]/[id]/[id] link state: [linkState]. Please verify connectivity to Fabric Interconnect. Acknowledging chassis might be required.
Explanation
The link for a network facing adapter interface is down. Cisco UCS Manager raises this fault when any of the following scenarios occur:
- Cisco UCS Manager cannot establish and/or validate the adapter’s connectivity to any of the fabric interconnects.
- The endpoint reports a link down or vNIC down event on the adapter link.
- The endpoint reports an errored link state or errored vNIC state event on the adapter link.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the adapter is connected, configured properly, and is running the recommended firmware version.
Step 2 If the server is stuck at discovery, decommission the server and reacknowledge the server slot.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltAdaptorExtIfLinkDown
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]
fltPortPIoLink-down
Fault Code: F0276
Message
[transport] port [portId] on chassis [id] oper state: [operState], reason: [stateQual][transport] port [slotId]/[aggrPortId]/[portId] on fabric interconnect [id] oper state: [operState], reason: [stateQual][transport] port [slotId]/[portId] on fabric interconnect [id] oper state: [operState], reason: [stateQual]
Explanation
This fault occurs when a fabric interconnect port is in link-down state. This state impacts the traffic destined for the port.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the physical link is properly connected between the fabric interconnect and the peer component.
Step 2 Verify that the configuration on the peer entity is properly configured and matches the fabric interconnect port configuration.
Step 3 Unconfigure and re-configure the port.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltPortPIoLinkDown
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]
fltPortPIoFailed
Fault Code: F0277
Message
[transport] port [portId] on chassis [id] oper state: [operState], reason: [stateQual][transport] port [slotId]/[aggrPortId]/[portId] on fabric interconnect [id] oper state: [operState], reason: [stateQual][transport] port [slotId]/[portId] on fabric interconnect [id] oper state: [operState], reason: [stateQual]
Explanation
This fault is raised on fabric interconnect ports and on server-facing ports on an IOM or a FEX module when UCSM detects that the port is not up and in failed state while it is expected to be up since it has been enabled by user and there is no known hardware failure or missing SFP issue and port license is valid. Additional reason is displayed by the fault description string.
Recommended Action
If you see this fault, Corrective action maybe taken based on reason information in the fault description whenever such a reason is displayed. If the fault description displays reason as "ENM source pinning failed" then it means that the fabric interconnect is operating in End-host Node Mode and the uplink port that this server facing port is pinned to is down or does not have appropriate VLAN configured. In case of such an error for an appliance port check the VLAN configuration on uplink port. A VLAN with same id as the one on the appliance port will also need to be configured on the uplink port. After setting the configuration right if you still see the fault then create a show tech-support file for Cisco UCS Manager and the chassis or FEX module, and then contact Cisco TAC.
Fault Details
mibFaultName: fltPortPIoFailed
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]
fltPortPIoHardware-failure
Fault Code: F0278
Message
[transport] port [portId] on chassis [id] oper state: [operState], reason: hardware-failure[transport] port [slotId]/[aggrPortId]/[portId] on fabric interconnect [id] oper state: [operState], reason: hardware-failure[transport] port [slotId]/[portId] on fabric interconnect [id] oper state: [operState], reason: hardware-failure
Explanation
This fault is raised on fabric interconnect ports and server-facing ports on an IOM or a FEX module when the system detects a hardware failure.
Recommended Action
If you see this fault, create a show tech-support file for Cisco UCS Manager and the chassis or FEX module, and then contact Cisco TAC.
Fault Details
mibFaultName: fltPortPIoHardwareFailure
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]
fltPortPIoSfp-not-present
Fault Code: F0279
Message
[transport] port [portId] on chassis [id] oper state: [operState][transport] port [slotId]/[aggrPortId]/[portId] on fabric interconnect [id] oper state: [operState][transport] port [slotId]/[portId] on fabric interconnect [id] oper state: [operState]
Explanation
When a fabric interconnect port is not in an unconfigured state, an SFP is required for its operation. This fault is raised to indicate that the SFP is missing from a configured port.
Recommended Action
If you see this fault, insert a supported SFP into the port on the fabric interconnect. A list of supported SFPs can be found on www.Cisco.com.
Fault Details
mibFaultName: fltPortPIoSfpNotPresent
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]
fltFabricExternalPcDown
Fault Code: F0282
Message
[type] port-channel [portId] on fabric interconnect [switchId] oper state: [operState], reason: [stateQual][type] port-channel [portId] on fabric interconnect [switchId] oper state: [operState], reason: [stateQual][type] port-channel [portId] on fabric interconnect [switchId] oper state: [operState], reason: [stateQual]
Explanation
This fault typically occurs when a fabric interconnect reports that a fabric port channel is operationally down.
Recommended Action
Fault Details
Cause: operational-state-down
mibFaultName: fltFabricExternalPcDown
moClass: fabric:ExternalPc
Affected MO: fabric/eth-estc/[id]/net-[name]/pc-switch-[switchId]-pc-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]
Affected MO: fabric/eth-estc/net-[name]/pc-switch-[switchId]-pc-[portId]
Affected MO: fabric/fc-estc/[id]/net-[name]/fcoepc-switch-[switchId]-fcoepc-[portId]
Affected MO: fabric/fc-estc/[id]/net-[name]/pc-switch-[switchId]-pc-[portId]
Affected MO: fabric/fc-estc/net-[name]/fcoepc-switch-[switchId]-fcoepc-[portId]
Affected MO: fabric/fc-estc/net-[name]/pc-switch-[switchId]-pc-[portId]
Affected MO: fabric/lan/[id]/net-[name]/pc-switch-[switchId]-pc-[portId]
Affected MO: fabric/lan/[id]/net-group-[name]/pc-switch-[switchId]-pc-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]
Affected MO: fabric/lan/net-[name]/pc-switch-[switchId]-pc-[portId]
Affected MO: fabric/lan/net-group-[name]/pc-switch-[switchId]-pc-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]
Affected MO: fabric/san/[id]/net-[name]/fcoepc-switch-[switchId]-fcoepc-[portId]
Affected MO: fabric/san/[id]/net-[name]/pc-switch-[switchId]-pc-[portId]
Affected MO: fabric/san/[id]/pc-[portId]
Affected MO: fabric/san/net-[name]/fcoepc-switch-[switchId]-fcoepc-[portId]
Affected MO: fabric/san/net-[name]/pc-switch-[switchId]-pc-[portId]
fltDcxVcDown
Fault Code: F0283
Message
[transport] VIF [id] on server [chassisId] / [slotId] of switch [switchId] down, reason: [stateQual][transport] VIF [id] on server [id] of switch [switchId] down, reason: [stateQual][transport] VIF [id] on server [chassisId]/[slotId]/[serverInstanceId] of switch [switchId] down, reason: [stateQual]
Explanation
This fault typically occurs when a fabric interconnect reports one of the following connectivity states for a virtual interface:
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the uplink physical interface is up.
Step 2 If the vNIC/vHBA is configured for a pin group, verify that the pin group targets are configured correctly.
Step 3 In the Network Control Policy for the vNIC, verify that the ’Action on Uplink Fail’ field is set to ’warning’.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltDcxVcDown
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/sas-expander-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/sas-expander-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/slot-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/slot-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/fex-[id]/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/fex-[id]/fabric-[switchId]/vc-[id]
Affected MO: sys/fex-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/fex-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/switch-[id]/ethlanflowmon/vc-[id]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/vc-[id]
Affected MO: sys/switch-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/switch-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/switch-[id]/sanmon-fc/mon-[name]/vc-[id]
fltNetworkElementInoperable
Fault Code: F0291
Message
Fabric Interconnect [id] operability: [operability]
Explanation
This fault typically occurs when the fabric interconnect cluster controller reports that the membership state of the fabric interconnect is down, indicating that the fabric interconnect is inoperable.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that both fabric interconnects in the cluster are running the same Kernel and System software versions.
Step 2 Verify that the fabric interconnects software version and the Cisco UCS Manager software versions are the same.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inoperable
mibFaultName: fltNetworkElementInoperable
Affected MO: sys/switch-[id]
fltMgmtEntityDegraded
Fault Code: F0293
Message
Fabric Interconnect [id], HA Cluster interconnect link failure
Explanation
This fault occurs when one of the cluster links (either L1 or L2) of a fabric interconnect is not operationally up. This issue impacts the full HA functionality of the fabric interconnect cluster.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that both L1 and L2 links are properly connected between the fabric interconnects.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltMgmtEntityDegraded
Affected MO: sys/mgmt-entity-[id]
fltMgmtEntityDown
Fault Code: F0294
Message
Fabric Interconnect [id], HA Cluster interconnect total link failure
Explanation
This fault occurs when both cluster links (L1 and L2) of the fabric interconnects are in a link-down state. This issue impacts the full HA functionality of the fabric interconnect cluster.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that both L1 and L2 links are properly connected between the fabric interconnects.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltMgmtEntityDown
Affected MO: sys/mgmt-entity-[id]
fltDcxNsFailed
Fault Code: F0304
Message
Server [chassisId]/[slotId] (service profile: [assignedToDn]) virtual network interface allocation failed.Server [id] (service profile: [assignedToDn]) virtual network interface allocation failed.Server [chassisId]/[slotId]/[serverInstanceId] (service profile: [assignedToDn]) virtual network interface allocation failed.
Explanation
The adapter’s vif-namespace activation failed due to insufficient resources. Cisco UCS Manager raises this fault when the number of deployed VIF resources exceeds the maximum VIF resources available on the adapter connected to the fabric interconnect.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the NS "size" and "used" resources to determine by how many vNICs the adapter exceeded the maximum.
Step 2 Unconfigure or delete all vNICs on the adapter above the maximum number.
Step 3 Add additional fabric uplinks from the IOM to the corresponding fabric interconnect and reacknowledge the chassis. This increases the "NS size" on the adapter.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: insufficient-resources
mibFaultName: fltDcxNsFailed
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/dcxns-[switchId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/dcxns-[switchId]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/dcxns-[switchId]
fltComputePhysicalInsufficientlyEquipped
Fault Code: F0305
Message
Server [id] (service profile: [assignedToDn]) has insufficient number of DIMMs, CPUs and/or adaptersServer [chassisId]/[slotId] (service profile: [assignedToDn]) has insufficient number of DIMMs, CPUs and/or adaptersServer [chassisId]/[slotId]/[serverInstanceId] (service profile: [assignedToDn]) has insufficient number of DIMMs and/or CPUs
Explanation
This fault typically occurs because Cisco UCS Manager has detected that the server has an insufficient number of DIMMs, CPUs, and/or adapters.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the DIMMs are installed in a supported configuration.
Step 2 Verify that an adapter and CPU are installed.
Step 3 Reacknowledge the server.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: insufficiently-equipped
mibFaultName: fltComputePhysicalInsufficientlyEquipped
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalIdentityUnestablishable
Fault Code: F0306
Message
Server [id] (service profile: [assignedToDn]) has an invalid FRUServer [chassisId]/[slotId] (service profile: [assignedToDn]) has an invalid FRUServer [chassisId]/[slotId]/[serverInstanceId] (service profile: [assignedToDn]) has an invalid FRU
Explanation
This fault typically occurs because Cisco UCS Manager has detected an unsupported server or CPU.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that a supported server and/or CPU is installed.
Step 2 Verify that the Cisco UCS Manager capability catalog is up to date.
Step 3 Reacknowledge the server.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: identity-unestablishable
mibFaultName: fltComputePhysicalIdentityUnestablishable
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltComputeBoardPowerError
Fault Code: F0310
Message
Motherboard of server [chassisId]/[slotId] (service profile: [assignedToDn]) power: [operPower]Motherboard of server [id] (service profile: [assignedToDn]) power: [operPower]Motherboard of server [chassisId]/[slotId]/[serverInstanceId] (service profile: [assignedToDn]) power: [operPower]
Explanation
This fault typically occurs when the server power sensors have detected a problem.
Recommended Action
If you see this fault, take the following actions:
Step 1 Make sure that the server is correctly installed in the chassis and that all cables are secure.
Step 2 If you reinstalled the server, reacknowledge it.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltComputeBoardPowerError
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board
Affected MO: sys/rack-unit-[id]/board
fltComputePhysicalPowerProblem
Fault Code: F0311
Message
Server [id] (service profile: [assignedToDn]) oper state: [operState]Server [chassisId]/[slotId] (service profile: [assignedToDn]) oper state: [operState]Server [chassisId]/[slotId]/[serverInstanceId] (service profile: [assignedToDn]) oper state: [operState]
Explanation
This fault typically occurs when the server power sensors have detected a problem.
Recommended Action
If you see this fault, take the following actions:
Step 1 Make sure that the server is correctly installed in the chassis and that all cables are secure.
Step 2 If you reinstalled the server, reacknowledge it.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltComputePhysicalPowerProblem
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalThermalProblem
Fault Code: F0312
Message
Server [id] (service profile: [assignedToDn]) oper state: [operState]Server [chassisId]/[slotId] (service profile: [assignedToDn]) oper state: [operState]Server [chassisId]/[slotId]/[serverInstanceId] (service profile: [assignedToDn]) oper state: [operState]
Explanation
This fault typically occurs when the server thermal sensors have detected a problem.
Recommended Action
If you see this fault, take the following actions:
Step 1 Make sure that the server fans are working properly.
Step 2 Wait for 24 hours to see if the problem resolves itself.
Step 3 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltComputePhysicalThermalProblem
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalBiosPostTimeout
Fault Code: F0313
Message
Server [id] (service profile: [assignedToDn]) BIOS failed power-on self testServer [chassisId]/[slotId] (service profile: [assignedToDn]) BIOS failed power-on self testServer [chassisId]/[slotId]/[serverInstanceId] (service profile: [assignedToDn]) BIOS failed power-on self test
Explanation
This fault typically occurs when the server has encountered a diagnostic failure.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the POST results for the server. In Cisco UCS Manager GUI, you can access the POST results from the General tab for the server. In Cisco UCS Manager CLI, you can access the POST results through the show post command under the scope for the server.
Step 2 Reacknowledge the server.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inoperable
mibFaultName: fltComputePhysicalBiosPostTimeout
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalDiscoveryFailed
Fault Code: F0314
Message
Server [id] (service profile: [assignedToDn]) discovery: [discovery]Server [chassisId]/[slotId] (service profile: [assignedToDn]) discovery: [discovery]Server [chassisId]/[slotId]/[serverInstanceId] (service profile: [assignedToDn]) discovery: [discovery]
Explanation
This fault typically occurs for one of the following reasons:
- The shallow discovery that occurs when the server associated with service profile failed.
- The server is down.
- The data path is not working.
- Cisco UCS Manager cannot communicate with the CIMC on the server.
- The server cannot communicate with the fabric interconnect.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the FSM tab and the current state of the server and any FSM operations.
Step 2 Check the error descriptions and see if any server components indicate a failure.
Step 3 If the server or a server component has failed, do the following:
a. Check the operational state of the server.
b. If the server is not operable, re-acknowledge the server.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltComputePhysicalDiscoveryFailed
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalAssociationFailed
Fault Code: F0315
Message
Service profile [assignedToDn] failed to associate with server [id]Service profile [assignedToDn] failed to associate with server [chassisId]/[slotId]Service profile [assignedToDn] failed to associate with server [chassisId]/[slotId]/[serverInstanceId]
Explanation
This fault typically occurs for one of the following reasons:
- The service profile could not be associated with the server.
- The server is down.
- The data path is not working.
- Cisco UCS Manager cannot communicate with one or more of the fabric interconnect, the server, or a component on the server.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the FSM tab and the current state of the server and any FSM operations.
Step 2 If the server is stuck in an inappropriate state, such as booting, power cycle the server.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: association-failed
mibFaultName: fltComputePhysicalAssociationFailed
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalInoperable
Fault Code: F0317
Message
Server [id] (service profile: [assignedToDn]) health: [operability]Server [chassisId]/[slotId] (service profile: [assignedToDn]) health: [operability]Server [chassisId]/[slotId]/[serverInstanceId] (service profile: [assignedToDn]) health: [operability]
Explanation
This fault typically occurs when the server has encountered a diagnostic failure.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the POST results for the server.In Cisco UCS Manager GUI, you can access the POST results from the General tab for the server. In Cisco UCS Manager CLI, you can access the POST results through the show post command under the scope for the server.
Step 2 Reacknowledge the server.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inoperable
mibFaultName: fltComputePhysicalInoperable
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalUnassignedMissing
Fault Code: F0318
Message
Server [id] missing (no profile)Server [chassisId]/[slotId] missing (no profile)Server [chassisId]/[slotId]/[serverInstanceId] (no profile) missing
Explanation
This fault typically occurs when the server, which is not associated with a service profile, was previously physically inserted in the slot, but cannot be detected by Cisco UCS Manager.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the server is physically present in the slot, remove and then reinsert it.
Step 2 If the server is not physically present in the slot, insert it.
Step 3 Reacknowledge the server.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltComputePhysicalUnassignedMissing
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalAssignedMissing
Fault Code: F0319
Message
Server [id] missing (service profile: [assignedToDn])Server [chassisId]/[slotId] missing (service profile: [assignedToDn])Server [chassisId]/[slotId]/[serverInstanceId] (service profile: [assignedToDn]) missing
Explanation
This fault typically occurs when the server, which is associated with a service profile, was previously physically inserted in the slot, but cannot be detected by Cisco UCS Manager.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the server is physically present in the slot, remove and then reinsert it.
Step 2 If the server is not physically present in the slot, reinsert it.
Step 3 Reacknowledge the server.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltComputePhysicalAssignedMissing
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalUnidentified
Fault Code: F0320
Message
Server [id] (service profile: [assignedToDn]) has an invalid FRU: [presence]Server [chassisId]/[slotId] (service profile: [assignedToDn]) has an invalid FRU: [presence]Server [chassisId]/[slotId]/[serverInstanceId] (service profile: [assignedToDn]) has an invalid FRU: [presence]
Explanation
This fault typically occurs because Cisco UCS Manager has detected an unsupported server or CPU.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that a supported server and/or CPU is installed.
Step 2 Verify that the Cisco UCS Manager capability catalog is up to date.
Step 3 Reacknowledge the server.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: identity-unestablishable
mibFaultName: fltComputePhysicalUnidentified
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalUnassignedInaccessible
Fault Code: F0321
Message
Server [id] (no profile) inaccessibleServer [chassisId]/[slotId] (no profile) inaccessibleServer [chassisId]/[slotId]/[serverInstanceId] (no profile) inaccessible
Explanation
This fault typically occurs when the server, which is not associated with a service profile, has lost connection to the fabric interconnects. This fault occurs if there are communication issues between the server CIMC and the fabric interconnects.
Recommended Action
If you see this fault, take the following actions:
Step 1 Wait a few minutes to see if the fault clears. This is typically a temporary issue, and can occur after a firmware upgrade.
Step 2 If the fault does not clear after a brief time, remove the server and then reinsert it.
Step 3 Reacknowledge the server.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inaccessible
mibFaultName: fltComputePhysicalUnassignedInaccessible
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalAssignedInaccessible
Fault Code: F0322
Message
Server [id] (service profile: [assignedToDn]) inaccessibleServer [chassisId]/[slotId] (service profile: [assignedToDn]) inaccessibleServer [chassisId]/[slotId]/[serverInstanceId] (service profile: [assignedToDn]) inaccessible
Explanation
This fault typically occurs when the server, which is associated with a service profile, has lost connection to the fabric interconnects. This fault occurs if there are communication issues between the server CIMC and the fabric interconnects.
Recommended Action
If you see this fault, take the following actions:
Step 1 Wait a few minutes to see if the fault clears. This is typically a temporary issue, and can occur after a firmware upgrade.
Step 2 If the fault does not clear after a brief time, remove the server and then reinsert it.
Step 3 Reacknowledge the server.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inaccessible
mibFaultName: fltComputePhysicalAssignedInaccessible
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltLsServerFailed
Fault Code: F0324
Message
Service profile [name] failed
Explanation
Server has failed. This fault typically occurs if the adapter power on self-test results in major and critical errors.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the POST results for the server. In Cisco UCS Manager GUI, you can access the POST results from the General tab for the server. In Cisco UCS Manager CLI, you can access the POST results through the show post command under the scope for the server.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltLsServerFailed
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]
fltLsServerDiscoveryFailed
Fault Code: F0326
Message
Service profile [name] discovery failed
Explanation
The shallow discovery that occurs when the server associated with service profile fails. If the server is up and the data path is working, this fault typically occurs as a result of one of the following issues:
- Cisco UCS Manager cannot communicate with the CIMC on the server.
- The server cannot communicate with the fabric interconnect.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the FSM tab and view the current state of the server and any FSM operations.
Step 2 Check the error descriptions and see if any server components indicate a failure.
Step 3 If the server or a server component has failed, do the following:
a. Check the operational state of the server.
b. If the server is not operable, reacknowledge the server.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltLsServerDiscoveryFailed
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]
fltLsServerConfigFailure
Fault Code: F0327
Message
Service profile [name] configuration failed due to [serverConfigIssues],[networkConfigIssues],[storageConfigIssues],[vnicConfigIssues],[iscsiConfigIssues]
Explanation
The named configuration qualifier is not available. This fault typically occurs because Cisco UCS Manager cannot successfully deploy the service profile due to a lack of resources that meet the named qualifier. For example, this fault can occur if the following occurs:
- The service profile is configured for a server adapter with vHBAs, and the adapter on the server does not support vHBAs.
- The service profile is created from a template which includes a server pool, and the server pool is empty.
- The local disk configuration policy in the service profile specifies the No Local Storage mode, but the server contains local disks.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the status of the server pool associated with the service profile. If the pool is empty, add more blade servers to it.
Step 2 Check the state of the server and ensure that it is in either the discovered or unassociated state.
Step 3 If the server is associated or undiscovered, do one of the following:
– Discover the server.
– Disassociate the server from the current service profile.
– Select another server to associate with the service profile.
Step 4 Review each policy in the service profile and verify that the selected server meets the requirements in the policy.
Step 5 If the server does not meet the requirements of the service profile, do one of the following:
– Modify the service profile to match the server.
– Select another server that does meet the requirements to associate with the service profile.
Step 6 If you can verify that the server meets the requirements of the service profile, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: configuration-failure
mibFaultName: fltLsServerConfigFailure
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]
fltLsServerMaintenanceFailed
Fault Code: F0329
Message
Service profile [name] maintenance failed
Explanation
Cisco UCS Manager currently does not use this fault.
Recommended Action
If you see this fault, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: maintenance-failed
mibFaultName: fltLsServerMaintenanceFailed
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]
fltLsServerRemoved
Fault Code: F0330
Message
Service profile [name] underlying resource removed
Explanation
Cisco UCS Manager cannot access the server associated with the service profile. This fault typically occurs as a result of one of the following issues:
- The server has been physically removed from the slot.
- The server is not available.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the server was removed from the slot, reinsert the server in the slot.
Step 2 If the server was not removed, remove and reinsert the server.NOTE: If the server is operable, this action can be disruptive to current operations.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltLsServerRemoved
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]
fltLsServerInaccessible
Fault Code: F0331
Message
Service profile [name] cannot be accessed
Explanation
Cisco UCS Manager cannot communicate with the CIMC on the server. This fault typically occurs as a result of one of the following issues:
- The server port or ports have failed.
- The I/O module is offline.
- The BMC has failed.
Recommended Action
If you see this fault, take the following actions:
Step 1 If Cisco UCS Manager shows that the CIMC is down, physically reseat the server.
Step 2 If Cisco UCS Manager shows that the server ports have failed, attempt to enable them.
Step 3 If the I/O module is offline, check for faults on that component.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: server-inaccessible
mibFaultName: fltLsServerInaccessible
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]
fltLsServerAssociationFailed
Fault Code: F0332
Message
Service profile [name] association failed for [pnDn]
Explanation
The service profile could not be associated with the server. This fault typically occurs because Cisco UCS Manager cannot communicate with one or more of the following:
- Fabric interconnect
- CIMC on the server
- SAS controller driver
- Server
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the FSM tab for the server and service profile to determine why the association failed.
Step 2 If the server is stuck in an inappropriate state, such as booting, power cycle the server.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: association-failed
mibFaultName: fltLsServerAssociationFailed
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]
fltLsServerUnassociated
Fault Code: F0334
Message
Service profile [name] is not associated
Explanation
The service profile has not yet been associated with a server or a server pool. This fault typically occurs as a result of one of the following issues:
- There is no acceptable server in the server pool.
- The association failed.
Recommended Action
If you see this fault, take the following actions:
Step 1 If you did not intend to associate the service profile, ignore the fault.
Step 2 If you did intend to associate the service profile, check the association failure fault.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltLsServerUnassociated
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]
fltLsServerServer-unfulfilled
Fault Code: F0337
Message
Server [pnDn] does not fulfill Service profile [name] due to [configQualifier]
Explanation
The server no longer meets the qualification requirements of the service profile. This fault typically occurs as a result of one of the following issues:
- The server has been physically changed.
- A required component of the server has failed.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the server inventory compare to the service profile qualifications.
Step 2 If the server inventory does not match the service profile qualifications, do one of the following:
– Associate the server with a different service profile.
– Ensure the server has sufficient resources to qualify for the current service profile.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltLsServerServerUnfulfilled
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]
fltEtherSwitchIntFIoSatellite-connection-absent
Fault Code: F0367
Message
No link between NIF port [chassisId]/[slotId]/[portId] and fabric interconnect [switchId]:[peerSlotId]/[peerPortId]
Explanation
This fault is raised when an I/O module fabric port, which links the I/O module port and the fabric interconnect, is not functional
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify the fabric interconnect-chassis topology. Make sure each I/O module is connected to only one fabric interconnect.
Step 2 Ensure that the fabric interconnect server port is configured and enabled.
Step 3 Ensure that the links are plugged in properly and reacknowledge the chassis.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: satellite-connection-absent
mibFaultName: fltEtherSwitchIntFIoSatelliteConnectionAbsent
moClass: ether:SwitchIntFIo
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]
fltEtherSwitchIntFIoSatellite-wiring-problem
Fault Code: F0368
Message
Invalid connection between IOM port [chassisId]/[slotId]/[portId] and fabric interconnect [switchId]:[peerSlotId]/[peerPortId]
Explanation
This fault typically occurs as a result of a satellite wiring problem on the network-facing interface of an I/O module and Cisco UCS Manager detects that at least one IOM uplink is misconnected to one of the fabric interconnect ports.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify the fabric interconnect-chassis topology. Make sure each I/O module is connected to only one fabric interconnect.
Step 2 Ensure that the links are plugged in properly and re-acknowledge the chassis.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: satellite-mis-connected
mibFaultName: fltEtherSwitchIntFIoSatelliteWiringProblem
moClass: ether:SwitchIntFIo
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]
fltEquipmentPsuPowerSupplyProblem
Fault Code: F0369
Message
Power supply [id] in chassis [id] power: [power]Power supply [id] in fabric interconnect [id] power: [power]Power supply [id] in fex [id] power: [power]Power supply [id] in server [id] power: [power]
Explanation
This fault typically occurs when Cisco UCS Manager detects a problem with a power supply unit in a chassis, fabric interconnect or a FEX. For example, the PSU is not functional.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the power cord is properly connected to the PSU and the power source.
Step 2 Verify that the power source is 220 volts.
Step 3 Verify that the PSU is properly installed in the chassis or fabric interconnect.
Step 4 Remove the PSU and reinstall it.
Step 5 Replace the PSU.
Step 6 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentPsuPowerSupplyProblem
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentFanDegraded
Fault Code: F0371
Message
Fan [id] in Fan Module [tray]-[id] under chassis [id] operability: [operability]Fan [id] in fabric interconnect [id] operability: [operability]Fan [id] in fex [id] operability: [operability]Fan [id] in Fan Module [tray]-[id] under server [id] operability: [operability]
Explanation
This fault occurs when one or more fans in a fan module are not operational, but at least one fan is operational.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the fan module.
Step 2 Review the Cisco UCS Site Preparation Guide and ensure the fan module has adequate airflow, including front and back clearance.
Step 3 Verify that the air flows are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Replace the faulty fan modules.
Step 8 Use the Cisco UCS power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 9 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-degraded
mibFaultName: fltEquipmentFanDegraded
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/fex-[id]/fan-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]
fltEquipmentFanInoperable
Fault Code: F0373
Message
Fan [id] in Fan Module [tray]-[id] under chassis [id] operability: [operability]Fan [id] in fabric interconnect [id] operability: [operability]Fan [id] in fex [id] operability: [operability]Fan [id] in Fan Module [tray]-[id] under server [id] operability: [operability]
Explanation
This fault occurs if a fan is not operational.
Recommended Action
If you see this fault, take the following actions:
Step 1 Remove fan module and re-install the fan module again. Remove only one fan module at a time.
Step 2 Replace fan module with a different fan module
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inoperable
mibFaultName: fltEquipmentFanInoperable
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/fex-[id]/fan-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]
fltEquipmentPsuInoperable
Fault Code: F0374
Message
Power supply [id] in chassis [id] operability: [operability]Power supply [id] in fabric interconnect [id] operability: [operability]Power supply [id] in fex [id] operability: [operability]Power supply [id] in server [id] operability: [operability]
Explanation
This fault typically occurs when Cisco UCS Manager detects a problem with a power supply unit in a chassis, fabric interconnect or a FEX. For example, the PSU is not functional.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the power cord is properly connected to the PSU and the power source.
Step 2 Verify that the power source is 220 volts.
Step 3 Verify that the PSU is properly installed in the chassis or fabric interconnect.
Step 4 Remove the PSU and reinstall it.
Step 5 Replace the PSU.
Step 6 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inoperable
mibFaultName: fltEquipmentPsuInoperable
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentIOCardRemoved
Fault Code: F0376
Message
[side] IOM [chassisId]/[id] ([switchId]) is removed
Explanation
This fault typically occurs because an I/O module is removed from the chassis. In a cluster configuration, the chassis fails over to the other I/O module. For a standalone configuration, the chassis associated with the I/O module loses network connectivity. This is a critical fault because it can result in the loss of network connectivity and disrupt data traffic through the I/O module.
Recommended Action
If you see this fault, take the following actions:
Step 1 Reinsert the I/O module and configure the fabric-interconnect ports connected to it as server ports and wait a few minutes to see if the fault clears.
Step 2 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentIOCardRemoved
moClass: equipment:IOCard
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltEquipmentFanModuleMissing
Fault Code: F0377
Message
Fan module [tray]-[id] in chassis [id] presence: [presence]Fan module [tray]-[id] in server [id] presence: [presence]Fan module [tray]-[id] in fabric interconnect [id] presence: [presence]
Explanation
This fault occurs if a fan Module slot is not equipped or removed from its slot
Recommended Action
If you see this fault, take the following actions:
Step 1 If the reported slot is empty, insert a fan module into the slot.
Step 2 If the reported slot contains a fan module, remove and reinsert the fan module.
Step 3 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentFanModuleMissing
moClass: equipment:FanModule
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]
fltEquipmentPsuMissing
Fault Code: F0378
Message
Power supply [id] in chassis [id] presence: [presence]Power supply [id] in fabric interconnect [id] presence: [presence]Power supply [id] in fex [id] presence: [presence]Power supply [id] in server [id] presence: [presence]
Explanation
This fault typically occurs when Cisco UCS Manager detects a problem with a power supply unit in a chassis, fabric interconnect, or a FEX. For example, the PSU is missing.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the PSU is physically present in the slot, remove and then reinsert it.
Step 2 If the PSU is not physically present in the slot, insert a new PSU.
Step 3 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentPsuMissing
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentIOCardThermalProblem
Fault Code: F0379
Message
[side] IOM [chassisId]/[id] ([switchId]) operState: [operState]
Explanation
This fault occurs when there is a thermal problem on an I/O module. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco UCS equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco UCS equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the I/O module.
Step 2 Review the Cisco UCS Site Preparation Guide to ensure the I/O modules have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco UCS chassis are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Replace faulty I/O modules.
Step 8 Use the Cisco UCS power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 9 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentIOCardThermalProblem
moClass: equipment:IOCard
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltEquipmentFanModuleThermalThresholdNonCritical
Fault Code: F0380
Message
Fan module [tray]-[id] in chassis [id] temperature: [thermal]Fan module [tray]-[id] in server [id] temperature: [thermal]Fan module [tray]-[id] in fabric interconnect [id] temperature: [thermal]
Explanation
This fault occurs when the temperature of a fan module has exceeded a non-critical threshold value, but is still below the critical threshold. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco UCS equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco UCS equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the fan module.
Step 2 Review the Cisco UCS Site Preparation Guide to ensure the fan modules have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Replace faulty fan modules.
Step 8 Use the Cisco UCS power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 9 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentFanModuleThermalThresholdNonCritical
moClass: equipment:FanModule
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]
fltEquipmentPsuThermalThresholdNonCritical
Fault Code: F0381
Message
Power supply [id] in chassis [id] temperature: [thermal]Power supply [id] in fabric interconnect [id] temperature: [thermal]Power supply [id] in server [id] temperature: [thermal]
Explanation
This fault occurs when the temperature of a PSU module has exceeded a non-critical threshold value, but is still below the critical threshold. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco UCS equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco UCS equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the PSU module.
Step 2 Review the Cisco UCS Site Preparation Guide to ensure the PSU modules have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Replace faulty PSU modules.
Step 8 Use the Cisco UCS power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 9 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentPsuThermalThresholdNonCritical
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentFanModuleThermalThresholdCritical
Fault Code: F0382
Message
Fan module [tray]-[id] in chassis [id] temperature: [thermal]Fan module [tray]-[id] in server [id] temperature: [thermal]Fan module [tray]-[id] in fabric interconnect [id] temperature: [thermal]
Explanation
This fault occurs when the temperature of a fan module has exceeded a critical threshold value. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco UCS equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco UCS equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the fan module.
Step 2 Review the Cisco UCS Site Preparation Guide to ensure the fan modules have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Replace faulty fan modules.
Step 8 Use the Cisco UCS power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 9 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentFanModuleThermalThresholdCritical
moClass: equipment:FanModule
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]
fltEquipmentPsuThermalThresholdCritical
Fault Code: F0383
Message
Power supply [id] in chassis [id] temperature: [thermal]Power supply [id] in fabric interconnect [id] temperature: [thermal]Power supply [id] in server [id] temperature: [thermal]
Explanation
This fault occurs when the temperature of a PSU module has exceeded a critical threshold value. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco UCS equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco UCS equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the PSU module.
Step 2 Review the Cisco UCS Site Preparation Guide to ensure the PSU modules have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Replace faulty PSU modules.
Step 8 Use the Cisco UCS power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 9 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentPsuThermalThresholdCritical
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentFanModuleThermalThresholdNonRecoverable
Fault Code: F0384
Message
Fan module [tray]-[id] in chassis [id] temperature: [thermal]Fan module [tray]-[id] in server [id] temperature: [thermal]Fan module [tray]-[id] in fabric interconnect [id] temperature: [thermal]
Explanation
This fault occurs when the temperature of a fan module has been out of operating range, and the issue is not recoverable. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco UCS equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco UCS equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the fan module.
Step 2 Review the Cisco UCS Site Preparation Guide to ensure the fan modules have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Replace faulty fan modules.
Step 8 Use the Cisco UCS power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 9 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentFanModuleThermalThresholdNonRecoverable
moClass: equipment:FanModule
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]
fltEquipmentPsuThermalThresholdNonRecoverable
Fault Code: F0385
Message
Power supply [id] in chassis [id] temperature: [thermal]Power supply [id] in fabric interconnect [id] temperature: [thermal]Power supply [id] in server [id] temperature: [thermal]
Explanation
This fault occurs when the temperature of a PSU module has been out of operating range, and the issue is not recoverable. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco UCS equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco UCS equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the PSU module.
Step 2 Review the Cisco UCS Site Preparation Guide to ensure the PSU modules have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Replace faulty PSU modules.
Step 8 Use the Cisco UCS power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 9 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentPsuThermalThresholdNonRecoverable
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentPsuVoltageThresholdNonCritical
Fault Code: F0387
Message
Power supply [id] in chassis [id] voltage: [voltage]Power supply [id] in fabric interconnect [id] voltage: [voltage]Power supply [id] in fex [id] voltage: [voltage]Power supply [id] in server [id] voltage: [voltage]
Explanation
This fault occurs when the PSU voltage is out of normal operating range, but hasn’t reached to a critical stage yet. Normally the PSU will recover itself from this situation.
Recommended Action
If you see this fault, take the following actions:
Step 1 Monitor the PSU for further degradation.
Step 2 Remove and reseat the PSU.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentPsuVoltageThresholdNonCritical
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentPsuVoltageThresholdCritical
Fault Code: F0389
Message
Power supply [id] in chassis [id] voltage: [voltage]Power supply [id] in fabric interconnect [id] voltage: [voltage]Power supply [id] in fex [id] voltage: [voltage]Power supply [id] in server [id] voltage: [voltage]
Explanation
This fault occurs when the PSU voltage has exceeded the specified hardware voltage rating.
Recommended Action
If you see this fault, take the following actions:
Step 1 Remove and reseat the PSU.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentPsuVoltageThresholdCritical
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentPsuVoltageThresholdNonRecoverable
Fault Code: F0391
Message
Power supply [id] in chassis [id] voltage: [voltage]Power supply [id] in fabric interconnect [id] voltage: [voltage]Power supply [id] in fex [id] voltage: [voltage]Power supply [id] in server [id] voltage: [voltage]
Explanation
This fault occurs when the PSU voltage has exceeded the specified hardware voltage rating and PSU hardware may have been damaged as a result or may be at risk of being damaged.
Recommended Action
If you see this fault, take the following actions:
Step 1 Remove and reseat the PSU.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentPsuVoltageThresholdNonRecoverable
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentPsuPerfThresholdNonCritical
Fault Code: F0392
Message
Power supply [id] in chassis [id] output current: [perf]Power supply [id] in fabric interconnect [id] output current: [perf]Power supply [id] in server [id] output current: [perf]
Explanation
This fault is raised as a warning if the current output of the PSU in a chassis, fabric interconnect, or rack server does not match the desired output value.
Recommended Action
If you see this fault, take the following actions:
Step 1 Monitor the PSU status.
Step 2 If possible, remove and reseat the PSU.
Step 3 If the above action did not resolve the issue, create a show tech-support file for the chassis and Cisco UCS Manager, and contact Cisco TAC.
Fault Details
Cause: performance-problem
mibFaultName: fltEquipmentPsuPerfThresholdNonCritical
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentPsuPerfThresholdCritical
Fault Code: F0393
Message
Power supply [id] in chassis [id] output current: [perf]Power supply [id] in fabric interconnect [id] output current: [perf]Power supply [id] in server [id] output current: [perf]
Explanation
This fault occurs if the current output of the PSU in a chassis, fabric interconnect, or rack server is far below or above the desired output value.
Recommended Action
If you see this fault, take the following actions:
Step 1 Monitor the PSU status.
Step 2 Plan to replace the PSU as soon as possible.
Step 3 If the above actions did not resolve the issue, create a show tech-support file for the chassis and Cisco UCS Manager, and contact Cisco TAC.
Fault Details
Cause: performance-problem
mibFaultName: fltEquipmentPsuPerfThresholdCritical
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentPsuPerfThresholdNonRecoverable
Fault Code: F0394
Message
Power supply [id] in chassis [id] output current: [perf]Power supply [id] in fabric interconnect [id] output current: [perf]Power supply [id] in server [id] output current: [perf]
Explanation
This fault occurs if the current output of the PSU in a chassis, fabric interconnect, or rack server is far above or below the non-recoverable threshold value.
Recommended Action
If you see this fault, plan to replace the PSU as soon as possible.
Fault Details
Cause: performance-problem
mibFaultName: fltEquipmentPsuPerfThresholdNonRecoverable
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentFanPerfThresholdNonCritical
Fault Code: F0395
Message
Fan [id] in Fan Module [tray]-[id] under chassis [id] speed: [perf]Fan [id] in fabric interconnect [id] speed: [perf]Fan [id] in Fan Module [tray]-[id] under server [id] speed: [perf]
Explanation
This fault occurs when the fan speed reading from the fan controller does not match the desired fan speed and is outside of the normal operating range. This can indicate a problem with a fan or with the reading from the fan controller.
Recommended Action
If you see this fault, take the following actions:
Step 1 Monitor the fan status.
Step 2 If the problem persists for a long period of time or if other fans do not show the same problem, reseat the fan.
Step 3 Replace the fan module.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: performance-problem
mibFaultName: fltEquipmentFanPerfThresholdNonCritical
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/fex-[id]/fan-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]
fltEquipmentFanPerfThresholdCritical
Fault Code: F0396
Message
Fan [id] in Fan Module [tray]-[id] under chassis [id] speed: [perf]Fan [id] in fabric interconnect [id] speed: [perf]Fan [id] in Fan Module [tray]-[id] under server [id] speed: [perf]
Explanation
This fault occurs when the fan speed read from the fan controller does not match the desired fan speed and has exceeded the critical threshold and is in risk of failure. This can indicate a problem with a fan or with the reading from the fan controller.
Recommended Action
If you see this fault, take the following actions:
Step 1 Monitor the fan status.
Step 2 If the problem persists for a long period of time or if other fans do not show the same problem, reseat the fan.
Step 3 If the above actions did not resolve the issue, create a show tech-support file for the chassis and contact Cisco TAC.
Fault Details
Cause: performance-problem
mibFaultName: fltEquipmentFanPerfThresholdCritical
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/fex-[id]/fan-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]
fltEquipmentFanPerfThresholdNonRecoverable
Fault Code: F0397
Message
Fan [id] in Fan Module [tray]-[id] under chassis [id] speed: [perf]Fan [id] in fabric interconnect [id] speed: [perf]Fan [id] in Fan Module [tray]-[id] under server [id] speed: [perf]
Explanation
This fault occurs when the fan speed read from the fan controller has far exceeded the desired fan speed. It frequently indicates that the fan has failed.
Recommended Action
If you see this fault, take the following actions:
Step 1 Replace the fan.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: performance-problem
mibFaultName: fltEquipmentFanPerfThresholdNonRecoverable
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/fex-[id]/fan-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]
fltEquipmentIOCardFirmwareUpgrade
Fault Code: F0398
Message
Chassis controller in IOM [chassisId]/[id] ([switchId]) firmware upgrade problem: [upgradeStatus]
Explanation
This fault typically occurs when an IOM upgrade fails.
Recommended Action
If you see this fault, take the following actions:
Step 1 On the FSM tab for the IOM, verify whether FSM for the upgrade completed successfully or failed.
Step 2 If the FSM failed, review the error message in the FSM.
Step 3 If the error message is self explanatory, verify the physical connectivity. For example, an error message could be No Connection to Endpoint or Link Down.
Step 4 If the above action did not resolve the issue and the fault persists, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: firmware-upgrade-problem
mibFaultName: fltEquipmentIOCardFirmwareUpgrade
moClass: equipment:IOCard
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltEquipmentChassisUnsupportedConnectivity
Fault Code: F0399
Message
Current connectivity for chassis [id] does not match supported topology
Explanation
This fault typically occurs when the current connectivity for a chassis does not match the configuration in the chassis discovery policy.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the correct number of links are configured in the chassis discovery policy.
Step 2 Check the state of the I/O module links.
Step 3 Reacknowledge the chassis.
Step 4 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: unsupported-connectivity-configuration
mibFaultName: fltEquipmentChassisUnsupportedConnectivity
moClass: equipment:Chassis
Affected MO: sys/chassis-[id]
fltEquipmentChassisUnacknowledged
Fault Code: F0400
Message
Chassis [id] connectivity configuration: [configState]
Explanation
This fault typically occurs when or more of the I/O module links from the chassis are unacknowledged.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the state of the I/O module links.
Step 2 Reacknowledge the chassis.
Step 3 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-unacknowledged
mibFaultName: fltEquipmentChassisUnacknowledged
moClass: equipment:Chassis
Affected MO: sys/chassis-[id]
fltEquipmentIOCardUnsupportedConnectivity
Fault Code: F0401
Message
IOM [chassisId]/[id] ([switchId]) current connectivity does not match discovery policy or connectivity is unsupported: [configState]
Explanation
This fault typically occurs when the current connectivity for an I/O module does not match the configuration in the chassis discovery policy.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the correct number of links are configured in the chassis discovery policy.
Step 2 Check the state of the I/O module links.
Step 3 Note that atleast 2 links are required to be connected between FEX and 61xx Fabric Interconnect
Step 4 Reacknowledge the chassis.
Step 5 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: unsupported-connectivity-configuration
mibFaultName: fltEquipmentIOCardUnsupportedConnectivity
moClass: equipment:IOCard
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltEquipmentIOCardUnacknowledged
Fault Code: F0402
Message
IOM [chassisId]/[id] ([switchId]) connectivity configuration: [configState]
Explanation
This fault typically occurs when an I/O module is unacknowledged.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the state of the I/O module links.
Step 2 Reacknowledge the chassis.
Step 3 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-unacknowledged
mibFaultName: fltEquipmentIOCardUnacknowledged
moClass: equipment:IOCard
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltEquipmentIOCardPeerDisconnected
Fault Code: F0403
Message
IOM [chassisId]/[id] ([switchId]) peer connectivity: [peerCommStatus]
Explanation
This fault typically occurs when an I/O module is unable to communicate with its peer I/O module.
Recommended Action
If you see this fault, take the following actions:
Step 1 Wait a few minutes to see if the fault clears. This is typically a temporary issue, and can occur after a firmware upgrade.
Step 2 If the fault does not clear after a few minutes, remove and reinsert the I/O module.
Step 3 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-disconnected
mibFaultName: fltEquipmentIOCardPeerDisconnected
moClass: equipment:IOCard
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltEquipmentChassisIdentity
Fault Code: F0404
Message
Chassis [id] has a mismatch between FRU identity reported by Fabric/IOM vs. FRU identity reported by CMC
Explanation
This fault typically occurs when the FRU information for an I/O module is corrupted or malformed.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the capability catalog in Cisco UCS Manager is up to date. If necessary, update the catalog.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentChassisIdentity
moClass: equipment:Chassis
Affected MO: sys/chassis-[id]
fltEquipmentIOCardIdentity
Fault Code: F0405
Message
[side] IOM [chassisId]/[id] ([switchId]) has a malformed FRU
Explanation
This fault typically occurs when the FRU information for an I/O module is corrupted or malformed.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the capability catalog in Cisco UCS Manager is up to date. If necessary, update the catalog.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentIOCardIdentity
moClass: equipment:IOCard
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltEquipmentFanModuleIdentity
Fault Code: F0406
Message
Fan Module [tray]-[id] in chassis [id] has a malformed FRUFan Module [tray]-[id] in server [id] has a malformed FRUFan Module [tray]-[id] in fabric interconnect [id] has a malformed FRU
Explanation
This fault typically occurs when the FRU information for a fan module is corrupted or malformed.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the capability catalog in Cisco UCS Manager is up to date. If necessary, update the catalog.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentFanModuleIdentity
moClass: equipment:FanModule
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]
fltEquipmentPsuIdentity
Fault Code: F0407
Message
Power supply [id] on chassis [id] has a malformed FRUPower supply [id] on server [id] has a malformed FRU
Explanation
This fault typically occurs when the FRU information for a power supply unit is corrupted or malformed.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the capability catalog in Cisco UCS Manager is up to date. If necessary, update the catalog.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentPsuIdentity
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentChassisPowerProblem
Fault Code: F0408
Message
Power state on chassis [id] is [power]
Explanation
This fault typically occurs when the chassis fails to meet the minimal power requirements defined in the power policy or when one or more power supplies have failed.
Recommended Action
If you see this fault, take the following actions:
Step 1 In Cisco UCS Manager, verify that all PSUs for the chassis are functional.
Step 2 Verify that all PSUs are seated properly within the chassis and are powered on.
Step 3 Physically unplug and replug the power cord into the chassis.
Step 4 If all PSUs are operating at maximum capacity, either add more PSUs to the chassis or redefine the power policy in Cisco UCS Manager.
Step 5 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentChassisPowerProblem
moClass: equipment:Chassis
Affected MO: sys/chassis-[id]
fltEquipmentChassisThermalThresholdCritical
Fault Code: F0409
Message
Thermal condition on chassis [id] is [thermal]
Explanation
This fault occurs under the following conditions:
Step 1 If a component within a chassis is operating outside the safe thermal operating range.
Step 2 If the chassis controller in the IOM is unable to determine the thermal condition of a blade server, the show tech-support file for the chassis provides a more detailed report of the most severe thermal conditions currently applicable for that chassis.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the temperature readings for the blade servers and IOM and ensure they are within the recommended thermal safe operating range.
Step 2 If the fault reports a "Thermal Sensor threshold crossing in blade" error for one or more blade servers, check if DIMM or processor temperature related faults have been raised against that blade.
Step 3 If the fault reports a "Thermal Sensor threshold crossing in IOM" error for one or both the IOMs, check if thermal faults have been raised against that IOM. Those faults include details of the thermal condition.
Step 4 If the fault reports a "Missing or Faulty Fan" error, check on the status of that fan. If it needs replacement, create a show tech-support file for the chassis and contact Cisco TAC.
Step 5 If the fault reports a "No connectivity between IOM and blade" or "Thermal Sensor readings unavailable from blade" error, check if that blade server is operational and whether any faults have been raised against that blade server. In this situation, the chassis controller may go into a fail-safe operating mode and the fan speeds may increase as a precautionary measure.
Step 6 If the above actions did not resolve the issue and the condition persists, create a show tech-support file for Cisco UCS Manager and the chassis and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentChassisThermalThresholdCritical
moClass: equipment:Chassis
Affected MO: sys/chassis-[id]
fltEquipmentChassisThermalThresholdNonCritical
Fault Code: F0410
Message
Thermal condition on chassis [id] is [thermal]
Explanation
UCSM raises this fault under the following conditions:
Step 1 If a component within a chassis is operating outside the safe thermal operating range.
Step 2 If the chassis controller in the IOM is unable to determine the thermal condition of a blade server, the show tech-support file for the chassis provides a more detailed report of the most severe thermal conditions currently applicable for that chassis.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the temperature readings for the blade servers and IOM and ensure they are within the recommended thermal safe operating range.
Step 2 If the fault reports a "Thermal Sensor threshold crossing in blade" error for one or more blade servers, check if DIMM or processor temperature related faults have been raised against that blade.
Step 3 If the fault reports a "Thermal Sensor threshold crossing in IOM" error for one or both the IOMs, check if thermal faults have been raised against that IOM. Those faults include details of the thermal condition.
Step 4 If the fault reports a "Missing or Faulty Fan" error, check on the status of that fan. If it needs replacement, create a show tech-support file for the chassis and contact Cisco TAC.
Step 5 If the fault reports a "No connectivity between IOM and blade" or "Thermal Sensor readings unavailable from blade" error, check if that blade server is operational and whether any faults have been raised against that blade server. In this situation, the chassis controller may go into a fail-safe operating mode and the fan speeds may increase as a precautionary measure.
Step 6 If the above actions did not resolve the issue and the condition persists, create a show tech-support file for Cisco UCS Manager and the chassis and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentChassisThermalThresholdNonCritical
moClass: equipment:Chassis
Affected MO: sys/chassis-[id]
fltEquipmentChassisThermalThresholdNonRecoverable
Fault Code: F0411
Message
Thermal condition on chassis [id] is [thermal]
Explanation
UCSM raises this fault under the following conditions:
Step 1 If a component within a chassis is operating outside the safe thermal operating range.
Step 2 If the chassis controller in the IOM is unable to determine the thermal condition of a blade server, the show tech-support file for the chassis provides a more detailed report of the most severe thermal conditions currently applicable for that chassis.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the temperature readings for the blade servers and IOM and ensure they are within the recommended thermal safe operating range.
Step 2 If the fault reports a "Thermal Sensor threshold crossing in blade" error for one or more blade servers, check if DIMM or processor temperature related faults have been raised against that blade.
Step 3 If the fault reports a "Thermal Sensor threshold crossing in IOM" error for one or both the IOMs, check if thermal faults have been raised against that IOM. Those faults include details of the thermal condition.
Step 4 If the fault reports a "Missing or Faulty Fan" error, check on the status of that fan. If it needs replacement, create a show tech-support file for the chassis and contact Cisco TAC.
Step 5 If the fault reports a "No connectivity between IOM and blade" or "Thermal Sensor readings unavailable from blade" error, check if that blade server is operational and whether any faults have been raised against that blade server. In this situation, the chassis controller may go into a fail-safe operating mode and the fan speeds may increase as a precautionary measure.
Step 6 If the above actions did not resolve the issue and the condition persists, create a show tech-support file for Cisco UCS Manager and the chassis and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentChassisThermalThresholdNonRecoverable
moClass: equipment:Chassis
Affected MO: sys/chassis-[id]
fltComputeBoardCmosVoltageThresholdCritical
Fault Code: F0424
Message
Possible loss of CMOS settings: CMOS battery voltage on server [chassisId]/[slotId] is [cmosVoltage]Possible loss of CMOS settings: CMOS battery voltage on server [id] is [cmosVoltage]Possible loss of CMOS settings: CMOS battery voltage on server [chassisId]/[slotId]/[serverInstanceId] is [cmosVoltage]
Explanation
This fault is raised when the CMOS battery voltage has dropped to lower than the normal operating range. This could impact the clock and other CMOS settings.
Recommended Action
If you see this fault, replace the battery.
Fault Details
mibFaultName: fltComputeBoardCmosVoltageThresholdCritical
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board
Affected MO: sys/rack-unit-[id]/board
fltComputeBoardCmosVoltageThresholdNonRecoverable
Fault Code: F0425
Message
Possible loss of CMOS settings: CMOS battery voltage on server [chassisId]/[slotId] is [cmosVoltage]Possible loss of CMOS settings: CMOS battery voltage on server [id] is [cmosVoltage]Possible loss of CMOS settings: CMOS battery voltage on server [chassisId]/[slotId]/[serverInstanceId] is [cmosVoltage]
Explanation
This fault is raised when the CMOS battery voltage has dropped quite low and is unlikely to recover. This impacts the clock and other CMOS settings.
Recommended Action
If you see this fault, replace the battery.
Fault Details
mibFaultName: fltComputeBoardCmosVoltageThresholdNonRecoverable
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board
Affected MO: sys/rack-unit-[id]/board
fltMgmtEntityElection-failure
Fault Code: F0428
Message
Fabric Interconnect [id], election of primary managemt instance has failed
Explanation
This fault occurs in an unlikely event that the fabric interconnects in a cluster configuration could not reach an agreement for selecting the primary fabric interconnect. This impacts the full HA functionality of the fabric interconnect cluster.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the initial setup configuration is correct on both fabric interconnects.
Step 2 Verify that the L1 and L2 links are properly connected between the fabric interconnects.
Step 3 In the Cisco UCS Manager CLI, run the cluster force primary local-mgmt command on one fabric interconnect.
Step 4 Reboot the fabric interconnects.
Step 5 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltMgmtEntityElectionFailure
Affected MO: sys/mgmt-entity-[id]
fltMgmtEntityHa-not-ready
Fault Code: F0429
Message
Fabric Interconnect [id], HA functionality not ready
Explanation
This fault occurs if Cisco UCS Manager cannot discover or communicate with one or more chassis or rack servers to write the HA Cluster state. This impacts the full HA functionality of the fabric interconnect cluster.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the initial setup configuration is correct on both fabric interconnects.
Step 2 Verify that the L1 and L2 links are properly connected between the fabric interconnects.
Step 3 Verify that the IOMs and/or FEXes are reachable and the server ports are enabled and operationally up.
Step 4 Verify that the chassis and/or rack servers are powered up and reachable
Step 5 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltMgmtEntityHaNotReady
Affected MO: sys/mgmt-entity-[id]
fltMgmtEntityVersion-incompatible
Fault Code: F0430
Message
Fabric Interconnect [id], management services, incompatible versions
Explanation
This fault occurs if the Cisco UCS Manager software on the subordinate fabric interconnect is not the same release as that of the primary fabric interconnect. This impacts the full HA functionality of the fabric interconnect cluster.
Recommended Action
If you see this fault, take the following actions:
Step 1 Upgrade the Cisco UCS Manager software on the subordinate fabric interconnect to the same release as the primary fabric interconnect and verify that both fabric interconnects are running the same release of Cisco UCS Manager.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: version-incompatible
mibFaultName: fltMgmtEntityVersionIncompatible
Affected MO: sys/mgmt-entity-[id]
fltEquipmentFanMissing
Fault Code: F0434
Message
Fan [id] in fabric interconnect [id] presence: [presence]Fan [id] in fex [id] presence: [presence]Fan [id] in Fan Module [tray]-[id] under server [id] presence: [presence]
Explanation
This fault occurs in the unlikely event that a fan in a fan module cannot be detected.
Recommended Action
If you see this fault, take the following actions:
Step 1 Insert/reinsert the fan module in the slot that is reporting the issue.
Step 2 Replace the fan module with a different fan module, if available.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentFanMissing
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/fex-[id]/fan-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]
fltEquipmentIOCardAutoUpgradingFirmware
Fault Code: F0435
Message
IOM [chassisId]/[id] ([switchId]) is auto upgrading firmware
Explanation
This fault typically occurs when an I/O module is auto upgrading. Auto-upgrade occurs when the firmware version on the IOM is incompatible with the firmware version on the fabric interconnect.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the IOM and fabric interconnects are not running the same firmware version, wait for the auto-upgrade to complete.
Step 2 When the IOM upgrade is completed, verify that Cisco UCS Manager has cleared this fault.
Step 3 If you see this fault after the IOM overall status changes to operable, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: auto-firmware-upgrade
mibFaultName: fltEquipmentIOCardAutoUpgradingFirmware
moClass: equipment:IOCard
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltFirmwarePackItemImageMissing
Fault Code: F0436
Message
[type] image with vendor [hwVendor], model [hwModel] and version [version] is deleted
Explanation
This fault typically occurs when the image to which a firmware package item refers is missing.
Recommended Action
If you see this fault, take the following actions:
Step 1 In Cisco UCS Manager GUI, navigate to the Firmware Management Images tab and determine whether the missing image is available or not.
Step 2 If the image is present, click on it to verify the model and vendor.
Step 3 If the image for the required model and vendor is not present, download that image or bundle from the Cisco.com website.
Step 4 If the image is present and the fault persists, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFirmwarePackItemImageMissing
moClass: firmware:PackItem
Affected MO: org-[name]/fw-catalog-pack-[name]/pack-image-[hwVendor]|[hwModel]|[type]
Affected MO: org-[name]/fw-chassis-pack-[name]/pack-image-[hwVendor]|[hwModel]|[type]
Affected MO: org-[name]/fw-host-pack-[name]/pack-image-[hwVendor]|[hwModel]|[type]
Affected MO: org-[name]/fw-infra-pack-[name]/pack-image-[hwVendor]|[hwModel]|[type]
Affected MO: org-[name]/fw-mgmt-pack-[name]/pack-image-[hwVendor]|[hwModel]|[type]
Affected MO: org-[name]/pack-image-[hwVendor]|[hwModel]|[type]
fltEtherSwitchIntFIoSatellite-wiring-numbers-unexpected
Fault Code: F0440
Message
Chassis discovery policy conflict: Link IOM [chassisId]/[slotId]/[portId] to peer port [switchId]:[peerChassisId]/[peerSlotId]/[peerPortId] not configured
Explanation
The configuration of the chassis discovery policy conflicts with the physical IOM uplinks. Cisco UCS Manager raises this fault when the chassis discovery policy is configured for more links than are physically cabled between the IOM uplinks on the chassis and the fabric interconnect.
Recommended Action
If you see this fault, take the following actions:
Step 1 Ensure that you cable at least the same number of IOM uplinks as are configured in the chassis discovery policy, and that you configure the corresponding server ports on the fabric interconnect.
Step 2 Reacknowledge the chassis.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: unexpected-number-of-links
mibFaultName: fltEtherSwitchIntFIoSatelliteWiringNumbersUnexpected
moClass: ether:SwitchIntFIo
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]
fltMgmtEntityManagement-services-failure
Fault Code: F0451
Message
Fabric Interconnect [id], management services have failed
Explanation
This fault occurs in an unlikely event that management services fail on a fabric interconnect. This impacts the full HA functionality of the fabric interconnect cluster.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the initial setup configuration is correct on both fabric interconnects.
Step 2 Verify that the L1 and L2 links are properly connected between the fabric interconnects.
Step 3 Reboot the fabric interconnects.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: management-services-failure
mibFaultName: fltMgmtEntityManagementServicesFailure
Affected MO: sys/mgmt-entity-[id]
fltMgmtEntityManagement-services-unresponsive
Fault Code: F0452
Message
Fabric Interconnect [id], management services are unresponsive
Explanation
This fault occurs when management services on a fabric interconnect are unresponsive. This impacts the full HA functionality of the fabric interconnect cluster.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the initial setup configuration is correct on both fabric interconnects.
Step 2 Verify that the L1 and L2 links are properly connected between the fabric interconnects.
Step 3 Reboot the fabric interconnects.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: management-services-unresponsive
mibFaultName: fltMgmtEntityManagementServicesUnresponsive
Affected MO: sys/mgmt-entity-[id]
fltEquipmentChassisInoperable
Fault Code: F0456
Message
Chassis [id] operability: [operability]
Explanation
This fault typically occurs for one of the following reasons:
- The fabric interconnect cannot communicate with a chassis. For a cluster configuration, this fault means that neither fabric interconnect can communicate with the chassis.
- The chassis has an invalid FRU.
Recommended Action
If you see this fault, take the following actions:
Step 1 In Cisco UCS Manager, reacknowledge the chassis that raised the fault.
Step 2 Physically unplug and replug the power cord into the chassis.
Step 3 Verify that the I/O modules are functional.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inoperable
mibFaultName: fltEquipmentChassisInoperable
moClass: equipment:Chassis
Affected MO: sys/chassis-[id]
fltEtherServerIntFIoHardware-failure
Fault Code: F0458
Message
IOM [transport] interface [portId] on chassis [id] oper state: [operState], reason: [stateQual]Fabric Interconnect [transport] interface [portId] on fabric interconnect [id] oper state: [operState], reason: [stateQual]IOM [transport] interface [portId] on fex [id] oper state: [operState], reason: [stateQual]
Explanation
This fault is raised on the IOM/FEX backplane ports when Cisco UCS Manager detects a hardware failure.
Recommended Action
If you see this fault, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEtherServerIntFIoHardwareFailure
moClass: ether:ServerIntFIo
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/rack-unit-[id]/diag/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]
fltDcxVcMgmt-vif-down
Fault Code: F0459
Message
IOM [chassisId] / [slotId] ([switchId]) management VIF [id] down, reason [stateQual]
Explanation
This fault occurs when the transport VIF for an I/O module is down. Cisco UCS Manager raises this fault when a fabric interconnect reports the connectivity state on virtual interface as one of the following:
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the chassis discovery has gone through successfully. Check the states on all communicating ports from end to end.
Step 2 If connectivity seems correct, decommission and recommission the chassis.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltDcxVcMgmtVifDown
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/sas-expander-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/sas-expander-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/slot-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/slot-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/fex-[id]/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/fex-[id]/fabric-[switchId]/vc-[id]
Affected MO: sys/fex-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/fex-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/switch-[id]/ethlanflowmon/vc-[id]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/vc-[id]
Affected MO: sys/switch-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/switch-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/switch-[id]/sanmon-fc/mon-[name]/vc-[id]
fltSysdebugMEpLogMEpLogLog
Fault Code: F0460
Message
Log capacity on [side] IOM [chassisId]/[id] is [capacity]Log capacity on Management Controller on server [chassisId]/[slotId] is [capacity]Log capacity on Management Controller on server [id] is [capacity]Log capacity on Management Controller on server [chassisId]/[slotId]/[serverInstanceId] is [capacity]
Explanation
This fault typically occurs because Cisco UCS Manager has detected that the system event log (SEL) on the server is approaching full capacity. The available capacity in the log is low. This is an info-level fault and can be ignored if you do not want to clear the SEL at this time.
Recommended Action
If you see this fault, you can clear the SEL in Cisco UCS Manager if desired.
Fault Details
mibFaultName: fltSysdebugMEpLogMEpLogLog
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/sas-expander-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/slot-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/fex-[id]/mgmt/log-[type]-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/mgmt/log-[type]-[id]
Affected MO: sys/switch-[id]/mgmt/log-[type]-[id]
fltSysdebugMEpLogMEpLogVeryLow
Fault Code: F0461
Message
Log capacity on [side] IOM [chassisId]/[id] is [capacity]Log capacity on Management Controller on server [chassisId]/[slotId] is [capacity]Log capacity on Management Controller on server [id] is [capacity]Log capacity on Management Controller on server [chassisId]/[slotId]/[serverInstanceId] is [capacity]
Explanation
This fault typically occurs because Cisco UCS Manager has detected that the system event log (SEL) on the server is almost full. The available capacity in the log is very low. This is an info-level fault and can be ignored if you do not want to clear the SEL at this time.
Recommended Action
If you see this fault, you can clear the SEL in Cisco UCS Manager if desired.
Fault Details
mibFaultName: fltSysdebugMEpLogMEpLogVeryLow
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/sas-expander-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/slot-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/fex-[id]/mgmt/log-[type]-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/mgmt/log-[type]-[id]
Affected MO: sys/switch-[id]/mgmt/log-[type]-[id]
fltSysdebugMEpLogMEpLogFull
Fault Code: F0462
Message
Log capacity on [side] IOM [chassisId]/[id] is [capacity]Log capacity on Management Controller on server [chassisId]/[slotId] is [capacity]Log capacity on Management Controller on server [id] is [capacity]Log capacity on Management Controller on server [chassisId]/[slotId]/[serverInstanceId] is [capacity]
Explanation
This fault typically occurs because Cisco UCS Manager could not transfer the SEL file to the location specified in the SEL policy. This is an info-level fault and can be ignored if you do not want to clear the SEL at this time.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify the configuration of the SEL policy to ensure that the location, user, and password provided are correct.
Step 2 If you do want to transfer and clear the SEL and the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltSysdebugMEpLogMEpLogFull
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/sas-expander-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/slot-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/fex-[id]/mgmt/log-[type]-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/mgmt/log-[type]-[id]
Affected MO: sys/switch-[id]/mgmt/log-[type]-[id]
fltComputePoolEmpty
Fault Code: F0463
Message
server pool [name] is empty
Explanation
This fault typically occurs when the selected server pool does not contain any servers.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify the qualifier settings in the server pool policy qualifications. If the policy was modified after the server was discovered, reacknowledge the server.
Step 2 Manually associate the service profile with a server.
Step 3 If the server pool is not used, ignore the fault.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltComputePoolEmpty
Affected MO: org-[name]/compute-pool-[name]
fltUuidpoolPoolEmpty
Fault Code: F0464
Message
UUID suffix pool [name] is empty
Explanation
This fault typically occurs when a UUID suffix pool does not contain any UUID suffixes.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the pool is in use, add a block of UUID suffixes to the pool.
Step 2 If the pool is not in use, ignore the fault.
Fault Details
mibFaultName: fltUuidpoolPoolEmpty
Affected MO: org-[name]/uuid-pool-[name]
fltIppoolPoolEmpty
Fault Code: F0465
Message
IP pool [name] is empty
Explanation
This fault typically occurs when an IP address pool does not contain any IP addresses.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the pool is in use, add a block of IP addresses to the pool.
Step 2 If the pool is not in use, ignore the fault.
Fault Details
mibFaultName: fltIppoolPoolEmpty
Affected MO: fabric/lan/network-sets/ip-pool-[name]
Affected MO: org-[name]/ip-pool-[name]
fltMacpoolPoolEmpty
Fault Code: F0466
Message
MAC pool [name] is empty
Explanation
This fault typically occurs when a MAC address pool does not contain any MAC addresses.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the pool is in use, add a block of MAC addresses to the pool.
Step 2 If the pool is not in use, ignore the fault.
Fault Details
mibFaultName: fltMacpoolPoolEmpty
Affected MO: org-[name]/mac-pool-[name]
fltFirmwareUpdatableImageUnusable
Fault Code: F0470
Message
backup image is unusable. reason: [operStateQual]
Explanation
This fault typically occurs when the backup firmware image on an endpoint is unusable.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the fault and the error message on the FSM tab for the endpoint to determine why the firmware image is unusable.
Step 2 If the firmware image is bad or corrupted, download another copy from the Cisco website and update the backup version on the endpoint with the new image.
Step 3 If the image is present and the fault persists, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFirmwareUpdatableImageUnusable
moClass: firmware:Updatable
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/blade-[slotId]/bios/fw-updatable
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/onboard-device-[deviceType]-[id]/fw-updatable
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/onboard-device-[deviceType]-[id]/fw-updatable
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/bios/fw-updatable
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/boardController/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/bios/fw-updatable
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/onboard-device-[deviceType]-[id]/fw-updatable
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/onboard-device-[deviceType]-[id]/fw-updatable
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/bios/fw-updatable
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/psu-[id]/fw-updatable
Affected MO: sys/chassis-[id]/sas-expander-[id]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/sas-expander-[id]/onboard-device-[deviceType]-[id]/fw-updatable
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/slot-[id]/boardController/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/storage-[type]-[id]/onboard-device-[deviceType]-[id]/fw-updatable
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/fw-updatable
Affected MO: sys/fex-[id]/mgmt/fw-updatable
Affected MO: sys/fex-[id]/psu-[id]/fw-updatable
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fw-updatable
Affected MO: sys/mgmt/fw-updatable
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fw-updatable
Affected MO: sys/rack-unit-[id]/bios/fw-updatable
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/mgmt/fw-updatable
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/onboard-device-[deviceType]-[id]/fw-updatable
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/mgmt/fw-updatable
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fw-updatable
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/fw-updatable
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/onboard-device-[deviceType]-[id]/fw-updatable
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fw-updatable
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/mgmt/fw-updatable
Affected MO: sys/rack-unit-[id]/ext-board-[id]/bios/fw-updatable
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fw-updatable
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fw-updatable
Affected MO: sys/rack-unit-[id]/mgmt/fw-updatable
Affected MO: sys/rack-unit-[id]/psu-[id]/fw-updatable
Affected MO: sys/switch-[id]/mgmt/fw-updatable
Affected MO: sys/switch-[id]/psu-[id]/fw-updatable
fltFirmwareBootUnitCantBoot
Fault Code: F0471
Message
unable to boot the startup image. End point booted with backup image
Explanation
This fault typically occurs when the startup firmware image on an endpoint is corrupted or invalid, and the endpoint cannot boot from that image.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the fault and the error message on the FSM tab for the endpoint to determine why the firmware image is unusable. The error message usually includes an explanation for why the endpoint could not boot from the startup image, such as Bad-Image or Checksum Failed.
Step 2 If the firmware image is bad or corrupted, download another copy from the Cisco website and update the startup version on the endpoint with the new image.
Step 3 If the fault persists, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFirmwareBootUnitCantBoot
moClass: firmware:BootUnit
Affected MO: capabilities/ep/mgmt-ext/fw-boot-def/bootunit-[type]
Affected MO: capabilities/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/graphics-card-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/onboard-device-[deviceType]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/onboard-device-[deviceType]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/graphics-card-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/onboard-device-[deviceType]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/onboard-device-[deviceType]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/psu-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/sas-expander-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/sas-expander-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/sas-expander-[id]/onboard-device-[deviceType]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/slot-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/onboard-device-[deviceType]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/fex-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/fex-[id]/psu-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/graphics-card-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/onboard-device-[deviceType]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/onboard-device-[deviceType]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/psu-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/switch-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/switch-[id]/psu-[id]/fw-boot-def/bootunit-[type]
fltFcpoolInitiatorsEmpty
Fault Code: F0476
Message
FC pool [purpose] [name] is empty
Explanation
This fault typically occurs when a WWN pool does not contain any WWNs.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the pool is in use, add a block of WWNs to the pool.
Step 2 If the pool is not in use, ignore the fault.
Fault Details
mibFaultName: fltFcpoolInitiatorsEmpty
moClass: fcpool:Initiators
Affected MO: org-[name]/wwn-pool-[name]
fltEquipmentIOCardInaccessible
Fault Code: F0478
Message
[side] IOM [chassisId]/[id] ([switchId]) is inaccessible
Explanation
This fault typically occurs because an I/O module has lost its connection to the fabric interconnects. In a cluster configuration, the chassis fails over to the other I/O module. For a standalone configuration, the chassis associated with the I/O module loses network connectivity. This is a critical fault because it can result in the loss of network connectivity and disrupt data traffic through the I/O module.
Recommended Action
If you see this fault, take the following actions:
Step 1 Wait a few minutes to see if the fault clears. This is typically a temporary issue, and can occur after a firmware upgrade.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inaccessible
mibFaultName: fltEquipmentIOCardInaccessible
moClass: equipment:IOCard
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltDcxVIfLinkState
Fault Code: F0479
Message
Virtual interface [id] link state is down
Explanation
This fault occurs when Cisco UCS cannot send or receive data through an uplink port.
Recommended Action
If you see this fault, take the following actions:
Step 1 Reenable the uplink port that failed.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltDcxVIfLinkState
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/vif-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/fcoe/vif-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vif-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fcoe/vif-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/vif-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vif-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/vif-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/fcoe/vif-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vif-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fcoe/vif-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/vif-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vif-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/vif-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/fcoe/vif-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vif-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fcoe/vif-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/vif-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vif-[id]
fltEquipmentFanModuleDegraded
Fault Code: F0480
Message
Fan module [tray]-[id] in chassis [id] operability: [operability]Fan module [tray]-[id] in server [id] operability: [operability]Fan module [tray]-[id] in fabric interconnect [id] operability: [operability]
Explanation
This fault occurs when a fan module is not operational.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the fan module.
Step 2 Review the Cisco UCS Site Preparation Guide to ensure the fan module has adequate airflow, including front and back clearance.
Step 3 Verify that the air flows for the fan module are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Use the Cisco UCS power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 8 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-degraded
mibFaultName: fltEquipmentFanModuleDegraded
moClass: equipment:FanModule
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]
fltEquipmentIOCardPost-failure
Fault Code: F0481
Message
[side] IOM [chassisId]/[id] ([switchId]) POST failure
Explanation
This fault typically occurs when an I/O module encounters errors during the Power On Self Test (POST). The impact of this fault varies according to the errors that were encountered during POST.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the POST results for the I/O module. In Cisco UCS Manager GUI, you can access the POST results from the General tab for the I/O module. In Cisco UCS Manager CLI, you can access the POST results through the show post command under the scope for the I/O module.
Step 2 If the POST results indicate FRU error, check if UCS manager has raised fault for the FRU and follow recommended action for the fault.
Step 3 Otherwise, reboot the I/O module.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentIOCardPostFailure
moClass: equipment:IOCard
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltEquipmentFanPerfThresholdLowerNonRecoverable
Fault Code: F0484
Message
Fan [id] in Fan Module [tray]-[id] under chassis [id] speed: [perf]Fan [id] in fabric interconnect [id] speed: [perf]Fan [id] in Fan Module [tray]-[id] under server [id] speed: [perf]
Explanation
This fault occurs when the fan speed reading from the fan controller is far below the desired fan speed, and the fan has likely failed.
Recommended Action
If you see this fault, create a detailed show tech-support file for the chassis and replace the fan module. If necessary, contact Cisco TAC.
Fault Details
Cause: performance-problem
mibFaultName: fltEquipmentFanPerfThresholdLowerNonRecoverable
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/fex-[id]/fan-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]
fltMemoryUnitIdentity-unestablishable
Fault Code: F0502
Message
DIMM [location] on server [chassisId]/[slotId] has an invalid FRUDIMM [location] on server [id] has an invalid FRUDIMM [location] on server [chassisId]/[slotId]/[serverInstanceId] has an invalid FRU
Explanation
This fault typically occurs because Cisco UCS Manager has detected unsupported DIMM in the server. For example, the model, vendor, or revision is not recognized.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the capability catalog in Cisco UCS Manager is up to date. If necessary, update the catalog.
Step 2 If the above action did not resolve the issue, you may have unsupported DIMMs or DIMM configuration in the server. Create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: identity-unestablishable
mibFaultName: fltMemoryUnitIdentityUnestablishable
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]/mem-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/memarray-[id]/mem-[id]
Affected MO: sys/rack-unit-[id]/board/memarray-[id]/mem-[id]
fltComputePhysicalPost-failure
Fault Code: F0517
Message
Server [id] POST or diagnostic failureServer [chassisId]/[slotId] POST or diagnostic failureServer [chassisId]/[slotId]/[serverInstanceId] POST or diagnostic failure
Explanation
This fault typically occurs when the server has encountered a diagnostic failure or an error during POST.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the POST results for the server. In Cisco UCS Manager GUI, you can access the POST results from the General tab for the server. In Cisco UCS Manager CLI, you can access the POST results through the show post command under the scope for the server.
Step 2 Reboot the server.
Step 3 If the above actions did not resolve the issue, execute the show tech-support command and contact Cisco Technical Support.
Fault Details
mibFaultName: fltComputePhysicalPostFailure
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltEquipmentPsuOffline
Fault Code: F0528
Message
Power supply [id] in chassis [id] power: [power]Power supply [id] in fabric interconnect [id] power: [power]Power supply [id] in fex [id] power: [power]Power supply [id] in server [id] power: [power]
Explanation
This fault typically occurs when Cisco UCS Manager detects that a power supply unit in a chassis, fabric interconnect, or FEX is offline.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the power cord is properly connected to the PSU and the power source.
Step 2 Verify that the power source is 220 volts.
Step 3 Verify that the PSU is properly installed in the chassis or fabric interconnect.
Step 4 Remove the PSU and reinstall it.
Step 5 Replace the PSU.
Step 6 If the above actions did not resolve the issue, note down the type of PSU, execute the show tech-support command, and contact Cisco Technical Support.
Fault Details
mibFaultName: fltEquipmentPsuOffline
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltStorageRaidBatteryInoperable
Fault Code: F0531
Message
RAID Battery on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]RAID Battery on server [id] operability: [operability]. Reason: [operQualifierReason]RAID Battery on chassis [id] operability: [operability]. Reason: [operQualifierReason]
Explanation
This fault occurs when the RAID backup unit is not operational.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the backup unit is a battery, replace the battery.
Step 2 If the backup unit is a supercapacitor type and the supercapacitor is missing, verify its presence and supply if missing.
Step 3 If the backup unit is a supercapacitor type and the TFM is missing, verify its presence and supply if missing.
Step 4 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inoperable
mibFaultName: fltStorageRaidBatteryInoperable
moClass: storage:RaidBattery
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/raid-battery
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/raid-battery
Affected MO: sys/chassis-[id]/storage-[type]-[id]/raid-battery
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/raid-battery
fltSysdebugMEpLogTransferError
Fault Code: F0532
Message
Server [chassisId]/[slotId] [type] transfer failed: [operState]Server [id] [type] transfer failed: [operState]
Explanation
This fault occurs when the transfer of a managed endpoint log file, such as the SEL, fails.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the fault is related to the SEL, verify the connectivity to the CIMC on the server.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: file-transfer-failed
mibFaultName: fltSysdebugMEpLogTransferError
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/sas-expander-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/slot-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/fex-[id]/mgmt/log-[type]-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/mgmt/log-[type]-[id]
Affected MO: sys/switch-[id]/mgmt/log-[type]-[id]
fltComputeRtcBatteryInoperable
Fault Code: F0533
Message
RTC Battery on server [chassisId]/[slotId] operability: [operability]
Explanation
This fault is raised when the CMOS battery voltage is below the normal operating range. This impacts the system clock.
Recommended Action
If you see this fault, replace the CMOS battery.
Fault Details
Cause: equipment-inoperable
mibFaultName: fltComputeRtcBatteryInoperable
moClass: compute:RtcBattery
Affected MO: sys/chassis-[id]/blade-[slotId]/board/rtc-battery
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/rtc-battery
Affected MO: sys/rack-unit-[id]/board/rtc-battery
fltMemoryBufferUnitThermalThresholdNonCritical
Fault Code: F0535
Message
Buffer Unit [id] on server [chassisId]/[slotId] temperature: [thermal]Buffer Unit [id] on server [id] temperature: [thermal]Buffer Unit [id] on server [chassisId]/[slotId]/[serverInstanceId] temperature: [thermal]
Explanation
This fault occurs when the temperature of a memory buffer unit on a blade or rack server exceeds a non-critical threshold value, but is still below the critical threshold. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco UCS equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco UCS equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
- If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the server.
Step 2 Review the Cisco UCS Site Preparation Guide to ensure the servers have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco UCS chassis or rack server are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Use the Cisco UCS power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 8 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltMemoryBufferUnitThermalThresholdNonCritical
moClass: memory:BufferUnit
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sensor-unit-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sensor-unit-[id]
Affected MO: sys/rack-unit-[id]/board/sensor-unit-[id]
fltMemoryBufferUnitThermalThresholdCritical
Fault Code: F0536
Message
Buffer Unit [id] on server [chassisId]/[slotId] temperature: [thermal]Buffer Unit [id] on server [id] temperature: [thermal]Buffer Unit [id] on server [chassisId]/[slotId]/[serverInstanceId] temperature: [thermal]
Explanation
This fault occurs when the temperature of a memory buffer unit on a blade or rack server exceeds a critical threshold value. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco UCS equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco UCS equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
- If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the server.
Step 2 Review the Cisco UCS Site Preparation Guide to ensure the servers have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco UCS chassis or rack server are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Use the Cisco UCS power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 8 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltMemoryBufferUnitThermalThresholdCritical
moClass: memory:BufferUnit
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sensor-unit-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sensor-unit-[id]
Affected MO: sys/rack-unit-[id]/board/sensor-unit-[id]
fltMemoryBufferUnitThermalThresholdNonRecoverable
Fault Code: F0537
Message
Buffer Unit [id] on server [chassisId]/[slotId] temperature: [thermal]Buffer Unit [id] on server [id] temperature: [thermal]Buffer Unit [id] on server [chassisId]/[slotId]/[serverInstanceId] temperature: [thermal]
Explanation
This fault occurs when the temperature of a memory buffer unit on a blade or rack server has been out of the operating range, and the issue is not recoverable. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco UCS equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco UCS equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
- If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the server.
Step 2 Review the Cisco UCS Site Preparation Guide to ensure the servers have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco UCS chassis or rack server are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Use the Cisco UCS power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 8 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltMemoryBufferUnitThermalThresholdNonRecoverable
moClass: memory:BufferUnit
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sensor-unit-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sensor-unit-[id]
Affected MO: sys/rack-unit-[id]/board/sensor-unit-[id]
fltComputeIOHubThermalNonCritical
Fault Code: F0538
Message
IO Hub on server [chassisId]/[slotId] temperature: [thermal]
Explanation
This fault is raised when the IO controller temperature is outside the upper or lower non-critical threshold.
Recommended Action
If you see this fault, monitor other environmental events related to this server and ensure the temperature ranges are within recommended ranges.
Fault Details
mibFaultName: fltComputeIOHubThermalNonCritical
Affected MO: sys/chassis-[id]/blade-[slotId]/board/iohub
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/iohub
Affected MO: sys/rack-unit-[id]/board/iohub
fltComputeIOHubThermalThresholdCritical
Fault Code: F0539
Message
IO Hub on server [chassisId]/[slotId] temperature: [thermal]
Explanation
This fault is raised when the IO controller temperature is outside the upper or lower critical threshold.
Recommended Action
If you see this fault, take the following actions:
Step 1 Monitor other environmental events related to the server and ensure the temperature ranges are within recommended ranges.
Step 2 Consider turning off the server for a while if possible.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltComputeIOHubThermalThresholdCritical
Affected MO: sys/chassis-[id]/blade-[slotId]/board/iohub
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/iohub
Affected MO: sys/rack-unit-[id]/board/iohub
fltComputeIOHubThermalThresholdNonRecoverable
Fault Code: F0540
Message
IO Hub on server [chassisId]/[slotId] temperature: [thermal]
Explanation
This fault is raised when the IO controller temperature is outside the recoverable range of operation.
Recommended Action
If you see this fault, take the following actions:
Step 1 Shutdown the server immediately.
Step 2 Create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltComputeIOHubThermalThresholdNonRecoverable
Affected MO: sys/chassis-[id]/blade-[slotId]/board/iohub
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/iohub
Affected MO: sys/rack-unit-[id]/board/iohub
fltEquipmentChassisIdentity-unestablishable
Fault Code: F0543
Message
Chassis [id] has an invalid FRU
Explanation
This fault typically occurs because Cisco UCS Manager has detected an unsupported chassis. For example, the model, vendor, or revision is not recognized.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the capability catalog in Cisco UCS Manager is up to date. If necessary, update the catalog.
Step 2 If the above action did not resolve the issue, execute the show tech-support command and contact Cisco technical support.
Fault Details
Cause: identity-unestablishable
mibFaultName: fltEquipmentChassisIdentityUnestablishable
moClass: equipment:Chassis
Affected MO: sys/chassis-[id]
fltSwVlanPortNsResourceStatus
Fault Code: F0549
Message
Vlan-Port Resource exceeded
Explanation
This fault occurs when the total number of configured VLANs in the Cisco UCS instance has exceeded the allowed maximum number of configured VLANs on the fabric interconnect.
Recommended Action
If you see this fault, take the following actions:
Step 1 In the Cisco UCS Manager CLI or Cisco UCS Manager GUI, check the port VLAN count to determine by how many VLANs the system is over the maximum.
Step 2 Reduce the VLAN port count in one of the following ways:
– Delete VLANs configured on the LAN cloud.
– Delete VLANs configured on vNICs.
– Unconfigure one or more vNICs.
– Unconfigure one or more uplink Ethernet ports on the fabric interconnect.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltSwVlanPortNsResourceStatus
Affected MO: sys/switch-[id]/vlan-port-ns
fltFabricLanPinGroupEmpty
Fault Code: F0621
Message
LAN Pin Group [name] is empty
Explanation
This fault typically occurs when a LAN pin group does not contain any targets.
Recommended Action
If you see this fault, add a target to the LAN pin group.
Fault Details
mibFaultName: fltFabricLanPinGroupEmpty
moClass: fabric:LanPinGroup
Affected MO: fabric/lan/lan-pin-group-[name]
fltFabricSanPinGroupEmpty
Fault Code: F0622
Message
SAN Pin Group [name] is empty
Explanation
This fault typically occurs when a SAN pin group does not contain any targets.
Recommended Action
If you see this fault, add a target to the SAN pin group.
Fault Details
mibFaultName: fltFabricSanPinGroupEmpty
moClass: fabric:SanPinGroup
Affected MO: fabric/san/san-pin-group-[name]
fltAdaptorExtEthIfMisConnect
Fault Code: F0625
Message
Adapter [id] eth interface [id] in server [id] mis-connected
Explanation
The link for a network-facing adapter interface is misconnected. Cisco UCS Manager raises this fault when any of the following scenarios occur:
- Cisco UCS Manager detects a new connectivity between a previously configured switch port or FEX port and the adapter’s external interface.
- Cisco UCS Manager detects a misconnected link between a fabric interconnect or FEX and its non-peer adapter’s interface.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check whether the adapter link is connected to a port that belongs to its peer fabric interconnect or FEX.
Step 2 If that connectivity seems correct, reacknowledge the server.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltAdaptorExtEthIfMisConnect
moClass: adaptor:ExtEthIf
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]
fltAdaptorHostEthIfMisConnect
Fault Code: F0626
Message
Adapter [id] eth interface [id] in server [id] mis-connected
Explanation
The link for a network-facing host interface is misconnected. Cisco UCS Manager raises this fault when any of the following scenarios occur:
- Cisco UCS Manager detects a new connectivity between a previously configured switch port and the host Ethernet interface.
- Cisco UCS Manager detects a misconnected link between the host interface and its non-peer fabric interconnect.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check whether the host Ethernet interface is connected to a port belonging to its peer fabric interconnect.
Step 2 If connectivity seems correct, reacknowledge the server.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltAdaptorHostEthIfMisConnect
moClass: adaptor:HostEthIf
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]
fltPowerBudgetPowerBudgetCmcProblem
Fault Code: F0635
Message
Power cap application failed for chassis [id]
Explanation
This fault typically occurs when the server CIMC has failed to enforce the configured power cap.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the power consumption of the chassis. If the chassis is consuming significantly more power than configured in the power cap, consider reducing the group cap so that the power consumption of other chassis consumption can be reduced to make up for the increase.
Step 2 If the above action did not resolve the issue, create a show tech-support file for Cisco UCS Manager and the chassis and then contact Cisco TAC.
Fault Details
mibFaultName: fltPowerBudgetPowerBudgetCmcProblem
Affected MO: sys/chassis-[id]/blade-[slotId]/budget
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/budget
Affected MO: sys/chassis-[id]/budget
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/budget
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/budget
Affected MO: sys/fex-[id]/budget
Affected MO: sys/rack-unit-[id]/budget
Affected MO: sys/rack-unit-[id]/ext-board-[id]/budget
Affected MO: sys/switch-[id]/budget
fltPowerBudgetPowerBudgetBmcProblem
Fault Code: F0637
Message
Power cap application failed for server [chassisId]/[slotId]Power cap application failed for server [id]
Explanation
This fault typically occurs when the server CIMC or BIOS has failed to enforce the configured power cap.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the power consumption of the blade server. If the server is consuming significantly more power than configured in the power cap, switch to a manual per blade cap configuration. If the power consumption is still too high, consider reducing the group cap so that the power consumption of other chassis consumption can be reduced to make up for the increase.
Step 2 If the power consumption is still too high, the CIMC or BIOS software is likely faulty.
Step 3 Create a show tech-support file for Cisco UCS Manager and the chassis and then contact Cisco TAC.
Fault Details
mibFaultName: fltPowerBudgetPowerBudgetBmcProblem
Affected MO: sys/chassis-[id]/blade-[slotId]/budget
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/budget
Affected MO: sys/chassis-[id]/budget
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/budget
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/budget
Affected MO: sys/fex-[id]/budget
Affected MO: sys/rack-unit-[id]/budget
Affected MO: sys/rack-unit-[id]/ext-board-[id]/budget
Affected MO: sys/switch-[id]/budget
fltPowerBudgetPowerBudgetDiscFail
Fault Code: F0640
Message
Insufficient power available to discover server [chassisId]/[slotId]Insufficient power available to discover server [id]
Explanation
This fault typically occurs when discovery fails due to unavailable power in the group.
Recommended Action
If you see this fault, take the following actions:
Step 1 Consider increasing the group cap.
Step 2 Reduce the number of blade servers or chassis in the Cisco UCS instance.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltPowerBudgetPowerBudgetDiscFail
Affected MO: sys/chassis-[id]/blade-[slotId]/budget
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/budget
Affected MO: sys/chassis-[id]/budget
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/budget
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/budget
Affected MO: sys/fex-[id]/budget
Affected MO: sys/rack-unit-[id]/budget
Affected MO: sys/rack-unit-[id]/ext-board-[id]/budget
Affected MO: sys/switch-[id]/budget
fltPowerGroupPowerGroupInsufficientBudget
Fault Code: F0642
Message
insufficient budget for power group [name]
Explanation
This fault typically occurs when the group cap is insufficient to meet the minimum hardware requirements.
Recommended Action
If you see this fault, take the following actions:
Step 1 Consider increasing the group cap.
Step 2 Reduce the number of blade servers or chassis in the Cisco UCS instance.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltPowerGroupPowerGroupInsufficientBudget
Affected MO: sys/power-ep/group-[name]
fltPowerGroupPowerGroupBudgetIncorrect
Fault Code: F0643
Message
admin committed insufficient for power group [name], using previous value [operCommitted]
Explanation
This fault typically occurs when the group cap is insufficient to meet the minimum hardware requirements. Under these circumstances, Cisco UCS Manager uses the previously entered group cap for provisioning.
Recommended Action
If you see this fault, take the following actions:
Step 1 Consider increasing the group cap.
Step 2 Reduce the number of blade servers or chassis in the Cisco UCS instance.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltPowerGroupPowerGroupBudgetIncorrect
Affected MO: sys/power-ep/group-[name]
fltLicenseInstanceGracePeriodWarning1
Fault Code: F0670
Message
One or more ports with license type [feature] on fabric-interconnect [scope] have started using license grace period.
Explanation
At least one port on the fabric interconnect is running in the grace period. This fault typically occurs if one or more ports on the fixed module are enabled after all default licenses have been assigned to a port.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the number of licenses installed and being used on each fabric interconnect. In the Cisco UCS Manager GUI, you can access the licensing information from the Admin tab for the fabric interconnect. In the Cisco UCS Manager CLI, you can access the licensing information by entering the show usage detail command under the license scope.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: license-graceperiod-entered
mibFaultName: fltLicenseInstanceGracePeriodWarning1
moClass: license:Instance
Affected MO: sys/license/feature-[name]-[vendor]-[version]/inst-[scope]
fltLicenseInstanceGracePeriodWarning2
Fault Code: F0671
Message
One or more ports with license type [feature] on fabric-interconnect [scope] are running in the grace period for more than 10 days
Explanation
At least one port on the fabric interconnect has been running in the grace period for more than 10 days. This fault typically occurs if one or more ports on the fixed module are enabled after all default licenses have been assigned to ports and the unlicensed ports have been running for more than 10 days.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the number of licenses installed and consumed on each fabric interconnect. In the Cisco UCS Manager GUI, you can access the licensing information from the Admin tab for the fabric interconnect. In the Cisco UCS Manager CLI, you can access the licensing information by entering the show usage detail command under the license scope.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: license-graceperiod-10days
mibFaultName: fltLicenseInstanceGracePeriodWarning2
moClass: license:Instance
Affected MO: sys/license/feature-[name]-[vendor]-[version]/inst-[scope]
fltLicenseInstanceGracePeriodWarning3
Fault Code: F0672
Message
One or more ports with license type [feature] on fabric-interconnect [scope] are running in the grace period for more than 30 days
Explanation
At least one port on the fabric interconnect has been running in the grace period for more than 30 days. This fault typically occurs if one or more ports on the fixed module are enabled after all default licenses have been assigned to ports and the unlicensed ports have been running for more than 30 days.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the number of licenses installed and consumed on each fabric interconnect. In the Cisco UCS Manager GUI, you can access the licensing information from the Admin tab for the fabric interconnect. In the Cisco UCS Manager CLI, you can access the licensing information by entering the show usage detail command under the license scope.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: license-graceperiod-30days
mibFaultName: fltLicenseInstanceGracePeriodWarning3
moClass: license:Instance
Affected MO: sys/license/feature-[name]-[vendor]-[version]/inst-[scope]
fltLicenseInstanceGracePeriodWarning4
Fault Code: F0673
Message
One or more ports with license type [feature] on fabric-interconnect [scope] are running in the grace period for more than 60 days
Explanation
At least one port on the fabric interconnect has been running in the grace period for more than 60 days. This fault typically occurs if one or more ports on the fixed module are enabled after all default licenses have been assigned to ports and the unlicensed ports have been running for more than 60 days.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the number of licenses installed and consumed on each fabric interconnect. In the Cisco UCS Manager GUI, you can access the licensing information from the Admin tab for the fabric interconnect. In the Cisco UCS Manager CLI, you can access the licensing information by entering the show usage detail command under the license scope.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: license-graceperiod-60days
mibFaultName: fltLicenseInstanceGracePeriodWarning4
moClass: license:Instance
Affected MO: sys/license/feature-[name]-[vendor]-[version]/inst-[scope]
fltLicenseInstanceGracePeriodWarning5
Fault Code: F0674
Message
One or more ports with license type [feature] on fabric-interconnect [scope] are running in the grace period for more than 90 days
Explanation
At least one port on the fabric interconnect has been running in the grace period for more than 90 days. This fault typically occurs if one or more ports on the fixed module are enabled after all default licenses have been assigned to ports and the unlicensed ports have been running for more than 90 days.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the number of licenses installed and consumed on each fabric interconnect. In the Cisco UCS Manager GUI, you can access the licensing information from the Admin tab for the fabric interconnect. In the Cisco UCS Manager CLI, you can access the licensing information by entering the show usage detail command under the license scope.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: license-graceperiod-90days
mibFaultName: fltLicenseInstanceGracePeriodWarning5
moClass: license:Instance
Affected MO: sys/license/feature-[name]-[vendor]-[version]/inst-[scope]
fltLicenseInstanceGracePeriodWarning6
Fault Code: F0675
Message
One or more ports with license type [feature] on fabric-interconnect [scope] are running in the grace period for more than 119 days
Explanation
At least one port on the fabric interconnect has been running in the grace period for more than 119 days. This fault typically occurs if one or more ports on the fixed module are enabled after all default licenses have been assigned to ports and the unlicensed ports have been running for more than 119 days.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the number of licenses installed and consumed on each fabric interconnect. In the Cisco UCS Manager GUI, you can access the licensing information from the Admin tab for the fabric interconnect. In the Cisco UCS Manager CLI, you can access the licensing information by entering the show usage detail command under the license scope.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: license-graceperiod-119days
mibFaultName: fltLicenseInstanceGracePeriodWarning6
moClass: license:Instance
Affected MO: sys/license/feature-[name]-[vendor]-[version]/inst-[scope]
fltLicenseInstanceGracePeriodWarning7
Fault Code: F0676
Message
Grace period of one or more ports with license type [feature] on fabric-interconnect [scope] is expired. Please acquire a license for the same.
Explanation
At least one port on the fabric interconnect has been running in the grace period for more than 120 days. This fault typically occurs if one or more ports on the fixed module are enabled after all default licenses have been assigned to ports and the unlicensed ports have been running for more than 120 days. At this stage, the system licensing state is set to expired.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the number of licenses installed and consumed on each fabric interconnect. In the Cisco UCS Manager GUI, you can access the licensing information from the Admin tab for the fabric interconnect. In the Cisco UCS Manager CLI, you can access the licensing information by entering the show usage detail command under the license scope.
Step 2 Disable the unlicensed ports to bring the number of enabled ports down to the number of total licenses.
Step 3 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC immediately to procure more licenses.
Fault Details
Cause: license-graceperiod-expired
mibFaultName: fltLicenseInstanceGracePeriodWarning7
moClass: license:Instance
Affected MO: sys/license/feature-[name]-[vendor]-[version]/inst-[scope]
fltLicenseFileBadLicenseFile
Fault Code: F0677
Message
license file [name] on fabric-interconnect [scope] can not be installed
Explanation
The installation of a license file on the fabric interconnect failed. This fault typically occurs if the license file is badly formatted or its host ID does not match that of the fabric interconnect.
Recommended Action
If you see this fault, take the following actions:
Step 1 In the Cisco UCS Manager CLI, check the host IDs for both fabric interconnects. You can access the host ID information by entering the show server-host-id detail command under the license scope.
Step 2 Match the host IDs with the contents of the license file. If the host ID matches that of one of the fabric interconnects, create a show tech-support file and contact Cisco TAC. If it does not match, contact Cisco TAC to obtain the correct license File.
Fault Details
Cause: license-file-uninstallable
mibFaultName: fltLicenseFileBadLicenseFile
Affected MO: sys/license/file-[scope]:[id]
fltLicenseFileFileNotDeleted
Fault Code: F0678
Message
license file [name] from fabric-interconnect [scope] could not be deleted
Explanation
The deletion of a license file on the fabric interconnect has failed. This fault typically occurs if license framework is not able to delete a file.
Recommended Action
If you see this fault, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: license-file-not-deleted
mibFaultName: fltLicenseFileFileNotDeleted
Affected MO: sys/license/file-[scope]:[id]
fltMgmtIfMisConnect
Fault Code: F0688
Message
Management Port [id] in server [id] is mis connected
Explanation
This fault occurs when the server and FEX connectivity changes.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the connectivity between the server and FEX.
Step 2 If the connectivity was changed by mistake, restore it to its previous configuration.
Step 3 If the connectivity change was intentional, reacknowledge the server.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltMgmtIfMisConnect
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/sas-expander-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/if-[id]
Affected MO: sys/chassis-[id]/slot-[id]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/mgmt/if-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/if-[id]
Affected MO: sys/fex-[id]/mgmt/if-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/if-[id]
Affected MO: sys/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/if-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/mgmt/if-[id]
Affected MO: sys/switch-[id]/mgmt/if-[id]
fltLsComputeBindingAssignmentRequirementsNotMet
Fault Code: F0689
Message
Assignment of service profile [name] to server [pnDn] failed
Explanation
The server could not be assigned to the selected service profile. This fault typically occurs as a result of one of the following issues:
- The selected server does not meet the requirements of the service profile.
- If the service profile was configured for restricted migration, the selected server does not match the currently or previously assigned server.
Recommended Action
If you see this fault, select a different server that meets the requirements of the service profile or matches the currently or previously assigned server.
Fault Details
mibFaultName: fltLsComputeBindingAssignmentRequirementsNotMet
moClass: ls:ComputeBinding
Affected MO: org-[name]/ls-[name]/pn
Affected MO: org-[name]/ls-[name]/pn-req
Affected MO: org-[name]/tier-[name]/ls-[name]/pn
Affected MO: org-[name]/tier-[name]/ls-[name]/pn-req
fltEquipmentFexPost-failure
Fault Code: F0702
Message
fex [id] POST failure
Explanation
This fault typically occurs when a FEX encounters errors during the Power On Self Test (POST). The impact of this fault varies depending on which errors were encountered during POST.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the POST results for the FEX. In the Cisco UCS Manager GUI, you can access the POST results from the General tab for the FEX. In the Cisco UCS Manager CLI, you can access the POST results by entering the show post command under the scope for the FEX.
Step 2 Reboot the FEX.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentFexPostFailure
Affected MO: sys/fex-[id]
fltEquipmentFexIdentity
Fault Code: F0703
Message
Fex [id] has a malformed FRU
Explanation
This fault typically occurs when the FRU information for a FEX is corrupted or malformed.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the capability catalog in Cisco UCS Manager is up to date. If necessary, update the catalog.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentFexIdentity
Affected MO: sys/fex-[id]
fltAdaptorHostEthIfMissing
Fault Code: F0708
Message
Connection to Adapter [id] eth interface [id] in server [id] missing
Explanation
The link for a network-facing host interface is missing. Cisco UCS Manager raises this fault when it detects missing connectivity between a previously configured switch port and its previous peer host interface.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check whether the adapter link is connected to a port that belongs to its non-peer fabric interconnect.
Step 2 If that connectivity seems correct, reacknowledge the server.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltAdaptorHostEthIfMissing
moClass: adaptor:HostEthIf
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]
fltPortPIoInvalid-sfp
Fault Code: F0713
Message
[transport] port [portId] on chassis [id] role : [ifRole] transceiver type:[xcvrType][transport] port [slotId]/[aggrPortId]/[portId] on fabric interconnect [id] role : [ifRole] transceiver type:[xcvrType][transport] port [slotId]/[portId] on fabric interconnect [id] role : [ifRole] transceiver type:[xcvrType]
Explanation
This fault is raised against a fabric interconnect port, network-facing IOM port, or FEX module port if an unsupported transceiver type is inserted. The port cannot be used if it has an unsupported transceiver.
Recommended Action
If you see this fault, replace the transceiver with a supported SFP type. Refer to the documentation on the Cisco website for a list of supported SFPs.
Fault Details
Cause: unsupported-transceiver
mibFaultName: fltPortPIoInvalidSfp
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]
fltMgmtIfMissing
Fault Code: F0717
Message
Connection to Management Port [id] in server [id] is missing
Explanation
This fault occurs when the connectivity between a server and FEX is removed or unconfigured.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the connectivity between the server and FEX.
Step 2 If the connectivity was changed by mistake, restore it to its previous configuration.
Step 3 If the connectivity change was intentional, reacknowledge the server.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltMgmtIfMissing
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/sas-expander-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/if-[id]
Affected MO: sys/chassis-[id]/slot-[id]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/mgmt/if-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/if-[id]
Affected MO: sys/fex-[id]/mgmt/if-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/if-[id]
Affected MO: sys/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/if-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/mgmt/if-[id]
Affected MO: sys/switch-[id]/mgmt/if-[id]
fltFabricEthLanPcEpDown
Fault Code: F0727
Message
[type] Member [slotId]/[aggrPortId]/[portId] of Port-Channel [portId] on fabric interconnect [id] is down, membership: [membership][type] Member [slotId]/[portId] of Port-Channel [portId] on fabric interconnect [id] is down, membership: [membership]
Explanation
This fault typically occurs when a member port in an Ethernet port channel is down.
Recommended Action
If you see this fault, take the following action:
Step 1 Check the link connectivity on the upstream Ethernet switch.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFabricEthLanPcEpDown
moClass: fabric:EthLanPcEp
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
fltFabricFcSanPcEpDown
Fault Code: F0728
Message
[type] Member [slotId]/[portId] of Port-Channel [portId] on fabric interconnect [id] is down, membership: [membership]
Explanation
This fault typically occurs when a member port in a Fibre Channel port channel is down.
Recommended Action
If you see this fault, take the following action:
Step 1 Check the link connectivity on the upstream Fibre Channel switch
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFabricFcSanPcEpDown
moClass: fabric:FcSanPcEp
Affected MO: fabric/san/[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
fltEquipmentIOCardThermalThresholdNonCritical
Fault Code: F0729
Message
[side] IOM [chassisId]/[id] ([switchId]) temperature: [thermal]
Explanation
This fault occurs when the temperature of an I/O module has exceeded a non-critical threshold value, but is still below the critical threshold. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco UCS equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco UCS equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
- If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the I/O module.
Step 2 Review the Cisco UCS Site Preparation Guide to ensure the chassis and I/O modules have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco UCS chassis and I/O module are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Use the Cisco UCS power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 8 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentIOCardThermalThresholdNonCritical
moClass: equipment:IOCard
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltEquipmentIOCardThermalThresholdCritical
Fault Code: F0730
Message
[side] IOM [chassisId]/[id] ([switchId]) temperature: [thermal]
Explanation
This fault occurs when the temperature of an I/O module has exceeded a critical threshold value. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco UCS equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco UCS equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
- If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the I/O module.
Step 2 Review the Cisco UCS Site Preparation Guide to ensure the chassis and I/O modules have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco UCS chassis and I/O module are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Replace the faulty I/O modules.
Step 8 Use the Cisco UCS power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 9 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentIOCardThermalThresholdCritical
moClass: equipment:IOCard
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltEquipmentIOCardThermalThresholdNonRecoverable
Fault Code: F0731
Message
[side] IOM [chassisId]/[id] ([switchId]) temperature: [thermal]
Explanation
This fault occurs when the temperature of an I/O module has been out of the operating range, and the issue is not recoverable. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco UCS equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco UCS equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
- If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the I/O module.
Step 2 Review the Cisco UCS Site Preparation Guide to ensure the chassis and I/O modules have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco UCS chassis and I/O module are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Replace the faulty I/O modules.
Step 8 Use the Cisco UCS power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 9 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentIOCardThermalThresholdNonRecoverable
moClass: equipment:IOCard
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltEquipmentChassisSeeprom-inoperable
Fault Code: F0733
Message
Device [id] SEEPROM operability: [seepromOperState]
Explanation
This fault occurs in the unlikely event that the Chassis shared storage (SEEPROM) is not operational.
Recommended Action
If you see this fault, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inoperable
mibFaultName: fltEquipmentChassisSeepromInoperable
moClass: equipment:Chassis
Affected MO: sys/chassis-[id]
fltFabricFcSanPcEpIncompatibleSpeed
Fault Code: F0734
Message
Member [slotId]/[portId] cannot be added to SAN Port-Channel [portId] on fabric interconnect [id], reason: [membership]
Explanation
This fault typically occurs when the maximum supported Fibre Channel speed of a port in a Fibre Channel port channel is incompatible with the admin speed configured for the port channel.
Recommended Action
If you see this fault, take one of the following actions:
- Change the admin speed of the port channel to match the maximum supported speed of the member ports in the port channel.
- Replace the expansion module in the fabric interconnect with one that matches the admin speed configured for the port channel.
Fault Details
Cause: incompatible-speed
mibFaultName: fltFabricFcSanPcEpIncompatibleSpeed
moClass: fabric:FcSanPcEp
Affected MO: fabric/san/[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
fltFabricFcSanPcIncompatibleSpeed
Fault Code: F0735
Message
Cannot set admin speed to the requested value, Speed incompatible with member ports in the port-channel
Explanation
This fault typically occurs when the maximum supported Fibre Channel speed of a port in a Fibre Channel port channel is incompatible with the admin speed configured for the port channel.
Recommended Action
If you see this fault, take one of the following actions:
- Change the admin speed of the port channel to match the maximum supported speed of the member ports in the port channel.
- Replace the expansion module in the fabric interconnect with one that matches the admin speed configured for the port channel.
Fault Details
Cause: incompatible-speed
mibFaultName: fltFabricFcSanPcIncompatibleSpeed
Affected MO: fabric/san/[id]/pc-[portId]
fltExtmgmtIfMgmtifdown
Fault Code: F0736
Message
Management interface on Fabric Interconnect [id] is [operState]
Explanation
This fault occurs when a fabric interconnect reports that the operational state of an external management interface is down.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the state transitions of the external management interface on the fabric interconnect.
Step 2 Check the link connectivity for the external management interface.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltExtmgmtIfMgmtifdown
Affected MO: sys/switch-[id]/extmgmt-intf
fltPowerChassisMemberPowerGroupCapInsufficient
Fault Code: F0740
Message
Chassis [id] cannot be capped as group cap is low. Please consider raising the cap.
Explanation
This fault typically occurs when an updated group cap is insufficient to meet the minimum hardware requirements and a chassis that has just been added to the power group cannot be capped as a result.
Recommended Action
If you see this fault, take the following actions:
Step 1 Consider increasing the group cap.
Step 2 Reduce the number of blade servers or chassis in the Cisco UCS instance.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: group-cap-insufficient
mibFaultName: fltPowerChassisMemberPowerGroupCapInsufficient
moClass: power:ChassisMember
Affected MO: sys/power-ep/group-[name]/ch-member-[id]
fltPowerChassisMemberChassisFirmwareProblem
Fault Code: F0741
Message
Chassis [id] cannot be capped as at least one of the CMC or CIMC or BIOS firmware version is less than 1.4. Please upgrade the firmware for cap to be applied.
Explanation
This fault typically occurs when the CIMC firmware on a server is an earlier release than Cisco UCS, Release 1.4.
Recommended Action
If you see this fault, consider upgrading the CIMC firmware, and the entire Cisco UCS instance if necessary, to Cisco UCS, Release 1.4 or later.
Fault Details
Cause: old-chassis-component-firmware
mibFaultName: fltPowerChassisMemberChassisFirmwareProblem
moClass: power:ChassisMember
Affected MO: sys/power-ep/group-[name]/ch-member-[id]
fltPowerChassisMemberChassisPsuInsufficient
Fault Code: F0742
Message
Chassis [id] cannot be capped as at least two PSU need to be powered
Explanation
This fault typically occurs when at least two PSUs are not powered on.
Recommended Action
If you see this fault, insert at least two PSUs and power them on.
Fault Details
mibFaultName: fltPowerChassisMemberChassisPsuInsufficient
moClass: power:ChassisMember
Affected MO: sys/power-ep/group-[name]/ch-member-[id]
fltPowerChassisMemberChassisPsuRedundanceFailure
Fault Code: F0743
Message
Chassis [id] was configured for redundancy, but running in a non-redundant configuration.
Explanation
This fault typically occurs when chassis power redundancy has failed.
Recommended Action
If you see this fault, take the following actions:
Step 1 Consider adding more PSUs to the chassis.
Step 2 Replace any non-functional PSUs.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: psu-redundancy-fail
mibFaultName: fltPowerChassisMemberChassisPsuRedundanceFailure
moClass: power:ChassisMember
Affected MO: sys/power-ep/group-[name]/ch-member-[id]
fltPowerBudgetPowerCapReachedCommit
Fault Code: F0744
Message
P-State lowered as consumption hit power cap for server [chassisId]/[slotId]P-State lowered as consumption hit power cap for server [id]
Explanation
This fault typically occurs when Cisco UCS Manager is actively capping the power for a blade server.
Recommended Action
If you see this fault, no action is needed.
Fault Details
Cause: power-consumption-hit-limit
mibFaultName: fltPowerBudgetPowerCapReachedCommit
Affected MO: sys/chassis-[id]/blade-[slotId]/budget
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/budget
Affected MO: sys/chassis-[id]/budget
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/budget
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/budget
Affected MO: sys/fex-[id]/budget
Affected MO: sys/rack-unit-[id]/budget
Affected MO: sys/rack-unit-[id]/ext-board-[id]/budget
Affected MO: sys/switch-[id]/budget
fltSysdebugAutoCoreFileExportTargetAutoCoreTransferFailure
Fault Code: F0747
Message
Auto core transfer failure at remote server [hostname]:[path] [exportFailureReason]
Explanation
This fault occurs when Cisco UCS Manager cannot transfer a core file to a remote TFTP server. This is typically the result of one of the following issues:
- The remote TFTP server is not accessible.
- One or more of the parameters for the TFTP server that are specified for the core export target, such as path, port, and server name, are incorrect.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify the connectivity to the remote server.
Step 2 Verify the path information of the remote server.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltSysdebugAutoCoreFileExportTargetAutoCoreTransferFailure
moClass: sysdebug:AutoCoreFileExportTarget
Affected MO: sys/sysdebug/file-export
fltFabricMonSpanConfigFail
Fault Code: F0757
Message
Configuration for traffic monitor [name] failed, reason: [configFailReason]
Explanation
This fault typically occurs when the configuration of a traffic monitoring session is incorrect.
Recommended Action
If you see this fault, correct the configuration problem provided in the fault description.
Fault Details
mibFaultName: fltFabricMonSpanConfigFail
Affected MO: fabric/lanmon/[id]/eth-mon-[name]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]
fltPowerBudgetChassisPsuInsufficient
Fault Code: F0764
Message
Chassis [id] cannot be capped as the available PSU power is not enough for the chassis and the blades. Please correct the problem by checking input power or replace the PSU
Explanation
This fault typically occurs when the available PSU power is not enough to deploy the power budget of chassis and blades.
Recommended Action
If you see this fault, check the PSU input power or replace the PSU.
Fault Details
mibFaultName: fltPowerBudgetChassisPsuInsufficient
Affected MO: sys/chassis-[id]/blade-[slotId]/budget
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/budget
Affected MO: sys/chassis-[id]/budget
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/budget
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/budget
Affected MO: sys/fex-[id]/budget
Affected MO: sys/rack-unit-[id]/budget
Affected MO: sys/rack-unit-[id]/ext-board-[id]/budget
Affected MO: sys/switch-[id]/budget
fltPowerBudgetTStateTransition
Fault Code: F0765
Message
Blade [chassisId]/[slotId] has been severely throttled. CIMC can recover if budget is redeployed to the blade or by rebooting the blade. If problem persists, please ensure that OS is ACPI compliantRack server [id] has been severely throttled. CIMC can recover if budget is redeployed to the blade or by rebooting the blade. If problem persists, please ensure that OS is ACPI compliant
Explanation
This fault typically occurs when the processor T-state is used to severely throttle the CPU.
Recommended Action
If you see this fault, take the following actions:
Step 1 Redeploy the power budget for the affected power group, blade server, or chassis.
Step 2 If the problem persists, reboot the blade server.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltPowerBudgetTStateTransition
Affected MO: sys/chassis-[id]/blade-[slotId]/budget
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/budget
Affected MO: sys/chassis-[id]/budget
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/budget
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/budget
Affected MO: sys/fex-[id]/budget
Affected MO: sys/rack-unit-[id]/budget
Affected MO: sys/rack-unit-[id]/ext-board-[id]/budget
Affected MO: sys/switch-[id]/budget
fltPowerPolicyPowerPolicyApplicationFail
Fault Code: F0766
Message
Insufficient budget to apply no-cap priority through policy [name]. Blades will continue to be capped
Explanation
This fault occurs when a power policy cannot be applied to one or more blade servers. The affected blade servers cannot operate normally without power capping due to the limited power budget for those servers.
Recommended Action
If you see this fault, take the following actions:
Step 1 Increase the power budget for the blade servers in the power policy.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltPowerPolicyPowerPolicyApplicationFail
Affected MO: org-[name]/power-policy-[name]
Affected MO: policy-ep/system-policies/power-policy-[name]
fltMgmtIfNew
Fault Code: F0772
Message
New connection discovered on Management Port [id] in server [id]
Explanation
This fault occurs when the connectivity between a server and a FEX is added or changed.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the connectivity between the server and FEX.
Step 2 If the connectivity was changed by mistake, restore it to its previous configuration.
Step 3 If the connectivity change was intentional, reacknowledge the server.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltMgmtIfNew
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/sas-expander-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/if-[id]
Affected MO: sys/chassis-[id]/slot-[id]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/mgmt/if-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/if-[id]
Affected MO: sys/fex-[id]/mgmt/if-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/if-[id]
Affected MO: sys/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/if-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/mgmt/if-[id]
Affected MO: sys/switch-[id]/mgmt/if-[id]
fltAdaptorExtEthIfMissing
Fault Code: F0775
Message
Connection to Adapter [id] eth interface [id] in server [id] missing
Explanation
The link for a network-facing adapter interface is misconnected. Cisco UCS Manager raises this fault when it detects that the connectivity between a previously configured port on a fabric interconnect or FEX and its prior peer network-facing adapter interface is misconnected or missing.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check whether the adapter interface is connected to a port belonging to its peer fabric interconnect or FEX.
Step 2 If the connectivity seems correct, reacknowledge the server.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltAdaptorExtEthIfMissing
moClass: adaptor:ExtEthIf
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]
fltStorageLocalDiskSlotEpUnusable
Fault Code: F0776
Message
Local disk [id] on server [serverId] is not usable by the operating system
Explanation
This fault occurs when the server disk drive is in a slot that is not supported by the storage controller.
Recommended Action
If you see this fault, take the following actions:
Step 1 Insert the server disk drive in a supported slot.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inoperable
mibFaultName: fltStorageLocalDiskSlotEpUnusable
moClass: storage:LocalDiskSlotEp
Affected MO: sys/chassis-[id]/blade-[slotId]/board/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/disk-[id]
Affected MO: sys/rack-unit-[id]/board/disk-[id]
fltFabricEthEstcPcEpDown
Fault Code: F0777
Message
[type] Member [slotId]/[aggrPortId]/[portId] of Port-Channel [portId] on fabric interconnect [id] is down, membership: [membership][type] Member [slotId]/[portId] of Port-Channel [portId] on fabric interconnect [id] is down, membership: [membership]
Explanation
This fault typically occurs when a member port in an Ethernet port channel is down.
Recommended Action
If you see this fault, take the following action:
Step 1 Check the link connectivity on the upstream Ethernet switch.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFabricEthEstcPcEpDown
moClass: fabric:EthEstcPcEp
Affected MO: fabric/eth-estc/[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
fltEquipmentFexIdentity-unestablishable
Fault Code: F0778
Message
Fex [id] has an invalid FRU
Explanation
This fault typically occurs because Cisco UCS Manager detected an unsupported chassis. For example, the model, vendor, or revision is not recognized.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the capability catalog in Cisco UCS Manager is up to date. If necessary, update the catalog.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: identity-unestablishable
mibFaultName: fltEquipmentFexIdentityUnestablishable
Affected MO: sys/fex-[id]
fltEquipmentFanModuleInoperable
Fault Code: F0794
Message
Fan module [tray]-[id] in chassis [id] operability: [operability]Fan module [tray]-[id] in server [id] operability: [operability]Fan module [tray]-[id] in fabric interconnect [id] operability: [operability]
Explanation
This fault occurs if a fan module is not operational.
Recommended Action
If you see this fault, take the following actions:
Step 1 Remove and reinstall the fan module. If multiple fans are affected by this fault, remove and reinstall one fan module at a time.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inoperable
mibFaultName: fltEquipmentFanModuleInoperable
moClass: equipment:FanModule
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]
fltLsmaintMaintPolicyUnresolvableScheduler
Fault Code: F0795
Message
Schedule [schedName] referenced by maintenance policy [name] does not exist
Explanation
The schedule that is referenced by the maintenance policy does not exist. This fault typically occurs as a result of one of the following issues:
- The schedule does not exist.
- The schedule was deleted.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check if the named schedule exists. If it is deleted or missing, try to create it.
Step 2 If the named schedule is deleted or missing, recreate it.
Step 3 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: non-existent-scheduler
mibFaultName: fltLsmaintMaintPolicyUnresolvableScheduler
moClass: lsmaint:MaintPolicy
Affected MO: org-[name]/maint-[name]
fltFabricVsanErrorDisabled
Fault Code: F0796
Message
VSAN [name] is [operState]
Explanation
This fault typically occurs when the VSAN has an ID in the restricted range between 3840 and 4078, and Fibre Channel end host mode is enabled on the fabric interconnect.
Recommended Action
If you see this fault, take the following actions:
Step 1 Delete the port channels on the fabric interconnect.
Step 2 Disable uplink trunking on the fabric-interconnect.
Step 3 Configure the fabric interconnect for fibre channel switch mode.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: vsan-misconfigured
mibFaultName: fltFabricVsanErrorDisabled
Affected MO: fabric/fc-estc/[id]/net-[name]
Affected MO: fabric/fc-estc/net-[name]
Affected MO: fabric/san/[id]/net-[name]
Affected MO: fabric/san/net-[name]
fltFabricVsanEpErrorDisabled
Fault Code: F0797
Message
[type] Port [slotId]/[portId] on fabric interconnect [switchId] has VSAN [id] in error disabled statePort channel [portId] on fabric interconnect [switchId] has VSAN [id] in error disabled state
Explanation
This fault typically occurs when a port is assigned to a VSAN that has an ID in the restricted range between 3840 and 4078) or is VSAN 4079, which is reserved.
Recommended Action
If you see this fault, take the following action:
Step 1 If the VSAN ID is in the restricted range between 3840 and 4078, do the following:
a. Delete the port channels on the fabric interconnect.
b. Disable uplink trunking on the fabric-interconnect.
c. Configure the fabric interconnect for fibre channel switch mode.
Step 2 If the VSAN is VSAN 4079, which is reserved, assign the port to a non-reserved VSAN.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: vsan-misconfigured
mibFaultName: fltFabricVsanEpErrorDisabled
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/vsan-[id]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/vsan-[id]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/vsan-[id]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/vsan-[id]
Affected MO: fabric/fc-estc/[id]/phys-fc-slot-[slotId]-port-[portId]/vsan-[id]
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]/vsan-[id]
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/vsan-[id]
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/vsan-[id]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/vsan-[id]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/vsan-[id]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/vsan-[id]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/vsan-[id]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/vsan-[id]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/vsan-[id]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/vsan-[id]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/vsan-[id]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/vsan-[id]
Affected MO: fabric/san/[id]/pc-[portId]/vsan-[id]
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]/vsan-[id]
Affected MO: fabric/san/[id]/phys-slot-[slotId]-port-[portId]/vsan-[id]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/vsan-[id]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/vsan-[id]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/vsan-[id]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/vsan-[id]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/vsan-[id]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/vsan-[id]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/vsan-[id]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/vsan-[id]
fltPowerBudgetFirmwareMismatch
Fault Code: F0798
Message
Firmware on blade [chassisId]/[slotId] does not allow chassis level power capping. Please consider upgrading to at least 1.4 version
Explanation
This fault typically occurs when the CIMC or BIOS firmware on a server is an earlier release than Cisco UCS, Release 1.4.
Recommended Action
If you see this fault, consider upgrading the CIMC firmware, and the entire Cisco UCS instance if necessary, to Cisco UCS, Release 1.4 or later.
Fault Details
mibFaultName: fltPowerBudgetFirmwareMismatch
Affected MO: sys/chassis-[id]/blade-[slotId]/budget
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/budget
Affected MO: sys/chassis-[id]/budget
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/budget
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/budget
Affected MO: sys/fex-[id]/budget
Affected MO: sys/rack-unit-[id]/budget
Affected MO: sys/rack-unit-[id]/ext-board-[id]/budget
Affected MO: sys/switch-[id]/budget
fltProcessorUnitIdentity-unestablishable
Fault Code: F0801
Message
Processor [id] on server [chassisId]/[slotId] has an invalid FRUProcessor [id] on server [id] has an invalid FRUProcessor [id] on server [chassisId]/[slotId]/[serverInstanceId] has an invalid FRU
Explanation
This fault typically occurs because Cisco UCS Manager has detected an unsupported CPU in the server. For example, the model, vendor, or revision is not recognized.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the capability catalog in Cisco UCS Manager is up to date. If necessary, update the catalog.
Step 2 If the above action did not resolve the issue, you may have an unsupported CPU configuration in the server. Create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: identity-unestablishable
mibFaultName: fltProcessorUnitIdentityUnestablishable
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/cpu-[id]
Affected MO: sys/rack-unit-[id]/board/cpu-[id]
fltIqnpoolPoolEmpty
Fault Code: F0821
Message
iqn pool [name] is empty
Explanation
This fault typically occurs when an IQN pool does not contain any IQNs.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the pool is in use, add a block of IQNs to the pool.
Step 2 If the pool is not in use, ignore the fault.
Fault Details
mibFaultName: fltIqnpoolPoolEmpty
Affected MO: org-[name]/iqn-pool-[name]
fltFabricDceSwSrvPcEpDown
Fault Code: F0831
Message
[type] Member [slotId]/[aggrPortId]/[portId] of Port-Channel [portId] on fabric interconnect [id] is down, membership: [membership][type] Member [slotId]/[portId] of Port-Channel [portId] on fabric interconnect [id] is down, membership: [membership]
Explanation
This fault typically occurs when a member port in a fabric port channel is down.
Recommended Action
If you see this fault, take the following action:
Step 1 Check the link connectivity between the FEX or IOM and the fabric interconnect.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFabricDceSwSrvPcEpDown
moClass: fabric:DceSwSrvPcEp
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
fltFabricEpMgrEpTransModeFail
Fault Code: F0832
Message
Port constraint violation on switch [id]: [confQual]
Explanation
This fault occurs when at least one logical interface is misconfigured. This can happen when upgrading to a different type or series of fabric interconnect or when importing a configuration.The configuration must meet the following constraints:
- The first Fibre Channel port must be an odd port number. This constraint cannot be violated when upgrading from a Cisco UCS 6100 series fabric interconnect to a Cisco UCS 6200 series fabric interconnect.
- All FC ports must be configured contiguously with intervening unconfigured FC ports. This can happen during an upgrade from a Cisco UCS 6100 series fabric interconnect when you import the configuration from a Cisco UCS 6100 series fabric interconnect configuration into a Cisco UCS 6200 series fabric interconnect. For example, the Cisco UCS 6100 series fabric interconnect has an FC expansion module with ports FC2/1 through FC2/6 configured. When you import that configuration into a Cisco UCS 6200 series fabric interconnect, FC ports 2/7 through 2/16 remain unconfigured. You can correct this problem by configuring the missing FC ports.
- Ethernet and FC port ranges cannot overlap. This can happen when upgrading from a Cisco UCS 6100 series fabric interconnect to a Cisco UCS 6200 series fabric interconnect. For example, some Cisco UCS 6100 expansion modules have FC and Ethernet ports with the same ID, such as FC port 2/1 and Ethernet port 2/1.
- There must be at most one logical port per fabric interconnect ID/module ID/port ID. For example, a port cannot be configured as both Ethernet and FC. This can happen during an upgrade from a Cisco UCS 6100 series fabric interconnect. For example, some Cisco UCS 6100 expansion modules have FC and Ethernet ports with the same ID, such as FC port 2/1 and Ethernet port 2/1.
- Within a module, the port IDs of Ethernet ports must be lower than the smallest FC port ID. This means that all Ethernet ports must be on the left and all FC ports on the right. This can happen during an upgrade from a Cisco UCS 6140 fabric interconnect with 40 ports on the fixed module to a Cisco UCS 6248 fabric interconnect with 32 ports on the fixed module. For example, if the Cisco UCS 6248 is initially configured with Ethernet ports 1/1 through 1/16 and FC ports 1/17 through 1/32, and you import a a configuration from the Cisco UCS 6140 with Ethernet ports 1/1 through 1/32 unconfigured and Ethernet ports 1/33 through 1/40, the resulting configuration is Ethernet 1/1 through 1/16, FC 1/17 through 1/32, and Ethernet 1/33 through 1/40. This is not a valid configuration. You must delete ports 1/33 through 1/40 to correct the configuration.
- A non-unified Ethernet port cannot be configured as an FC port. Please note the following:
– This constraint cannot be violated when upgrading from a Cisco UCS 6100 series fabric interconnect to a Cisco UCS 6200 series fabric interconnect.
– This constraint can be violated when downgrading from a Cisco UCS 6200 series fabric interconnect to a Cisco UCS 6100 series fabric interconnect.
– This constraint can be violated when pre-provisioning a port on a Cisco UCS 6100 series fabric interconnect and then inserting an expansion module that does not match the requirement.
- A non-unified FC port cannot be configured as an Ethernet port. Please note the following:
– This constraint cannot be violated when upgrading from a Cisco UCS 6100 series fabric interconnect to a Cisco UCS 6200 series fabric interconnect.
– This constraint can be violated when downgrading from a Cisco UCS 6200 series fabric interconnect to a Cisco UCS 6100 series fabric interconnect.
– This constraint can be violated when pre-provisioning a port on a Cisco UCS 6100 series fabric interconnect and then inserting an expansion module that does not match the requirement.
- On a Cisco UCS 6100 series fabric interconnect, server ports cannot be configured on expansion modules. This constraint can be violated when downgrading from a Cisco UCS 6200 series fabric interconnect to a Cisco UCS 6100 series fabric interconnect.
Recommended Action
If you see this fault, take the following action:
Step 1 Create a list of all logical interfaces that are misconfigured and have caused an ’error-misconfigured’ fault.
Step 2 For each logical interface, note the reason listed in the fault for the misconfiguration.
Step 3 Log into Cisco UCS Manager and correct each misconfigured logical interface. If you used the Cisco UCS Manager CLI, commit all changes.
Step 4 Review any faults or error messages that describe additional misconfigurations and correct those errors.
Step 5 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFabricEpMgrEpTransModeFail
fltFabricVlanMisconfigured
Fault Code: F0833
Message
VLAN [name] is [operState] because of conflicting vlan-id with a fcoe-vlan
Explanation
This fault typically occurs when VLAN has the same ID as an FCoE VLAN. This issue can cause disruption of traffic.
Recommended Action
If you see this fault, take the following action:
Step 1 Check the VLAN ID.
Step 2 If the ID of the VLAN matches the ID of the FCoE VLAN assigned to a VLAN in the same fabric interconnect, change the ID of either the VLAN or the FCoE VLAN.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: vlan-misconfigured
mibFaultName: fltFabricVlanMisconfigured
Affected MO: fabric/eth-estc/[id]/net-[name]
Affected MO: fabric/eth-estc/net-[name]
Affected MO: fabric/lan/[id]/net-[name]
Affected MO: fabric/lan/net-[name]
fltFabricPIoEpErrorMisconfigured
Fault Code: F0834
Message
Interface [name] is [operState]. Reason: [operStateReason]
Explanation
This fault occurs when a logical interface is misconfigured. This can happen when upgrading to a different type or series of fabric interconnect or when importing a configuration.
Recommended Action
If you see this fault, take the following action:
Step 1 Create a list of all logical interfaces that are misconfigured and have caused an ’error-misconfigured’ fault.
Step 2 For each logical interface, note the reason listed in the fault for the misconfiguration.
Step 3 Log into Cisco UCS Manager and correct each misconfigured logical interface. If you used the Cisco UCS Manager CLI, commit all changes.
Step 4 Review any faults or error messages that describe additional misconfigurations and correct those errors.
Step 5 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: interface-misconfigured
mibFaultName: fltFabricPIoEpErrorMisconfigured
Affected MO: fabric/eth-estc/[id]/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/eth-target-ep-[name]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/net-[name]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/phys-fc-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/net-[name]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/net-group-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/net-group-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/net-group-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/lan/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/net-group-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/net-group-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/net-group-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/net-[name]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/san/net-[name]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/san/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/san/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/san/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/server/cart-ep-ven-[vendor]-mod-[model]-ser-[serial]
Affected MO: fabric/server/chassis-[chassisId]
Affected MO: fabric/server/chassis-[chassisId]/cart-slot-[slotId]
Affected MO: fabric/server/chassis-[chassisId]/cart-slot-[slotId]/ins-[serverInstanceId]
Affected MO: fabric/server/chassis-[chassisId]/slot-[slotId]
Affected MO: fabric/server/chassis-ep-ven-[vendor]-mod[model]-ser-[serial]
Affected MO: fabric/server/compute-ep-ven-[vendor]-mod-[model]-ser-[serial]
Affected MO: fabric/server/sw-[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-port-[portId]
Affected MO: sys/switch-[id]/access-eth/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/eth-target-[name]
Affected MO: sys/switch-[id]/border-eth/ethestc-ep-slot-[slotId]port-[portId]/eth-target-[name]
Affected MO: sys/switch-[id]/border-eth/pc-[portId]/eth-target-[name]
Affected MO: sys/switch-[id]/border-eth/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/eth-target-[name]
Affected MO: sys/switch-[id]/border-fc/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/eth-target-[name]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/pc-[portId]/eth-target-[name]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/eth-target-[name]
Affected MO: sys/switch-[id]/phys/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/eth-target-[name]
Affected MO: sys/switch-[id]/sanmon-fc/mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/eth-target-[name]
fltFabricEthLanEpMissingPrimaryVlan
Fault Code: F0835
Message
Primary vlan missing from fabric: [switchId], port: [slotId]/[aggrPortId]/[portId].Primary vlan missing from fabric: [switchId], port: [slotId]/[portId].
Explanation
This fault occurs when an uplink port or port channel is configured with a primary VLAN that does not exist in the Cisco UCS instance.
Recommended Action
If you see this fault, take the following action:
Step 1 Update the configuration of the port or port channel to include a primary VLAN.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: missing-primary-vlan
mibFaultName: fltFabricEthLanEpMissingPrimaryVlan
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
fltFabricEthLanPcMissingPrimaryVlan
Fault Code: F0836
Message
Primary vlan missing from fabric: [switchId], port-channel: [portId].
Explanation
This fault occurs when an uplink port or port channel is configured with a primary VLAN that does not exist in the Cisco UCS instance.
Recommended Action
If you see this fault, take the following action:
Step 1 Update the configuration of the port or port channel to include a primary VLAN.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: missing-primary-vlan
mibFaultName: fltFabricEthLanPcMissingPrimaryVlan
Affected MO: fabric/lan/[id]/pc-[portId]
fltVnicEtherPinningMismatch
Fault Code: F0840
Message
Hard pinning target for eth vNIC [name], service profile [name] does not have all the required vlans configured
Explanation
This fault occurs when one or more VLANs required by vNIC in a service profile are not configured on the target uplink port or port channel for a hard-pinned LAN pin group.
Recommended Action
If you see this fault, take the following actions:
Step 1 In the LAN Uplinks Manager of the Cisco UCS Manager GUI, configure all of the VLANs in the vNIC in the target uplink port or port channel for the LAN pin group. If you prefer to use the Cisco UCS Manager CLI, navigate to scope /eth-uplink/vlan and create the required member ports for the LAN pin group.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltVnicEtherPinningMismatch
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]
fltVnicEtherPinningMisconfig
Fault Code: F0841
Message
Hard pinning target for eth vNIC [name], service profile [name] is missing or misconfigured
Explanation
This fault occurs when one or more vNIC target uplink ports or port channels for a hard-pinned LAN pin group are either missing or misconfigured as the wrong port type.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the LAN pin group configuration.
Step 2 Correct the configuration of the port and port channels in the pin group.
Step 3 Ensure that all required vLANs are allowed on the target ports or port channels.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltVnicEtherPinningMisconfig
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]
fltProcessorUnitDisabled
Fault Code: F0842
Message
Processor [id] on server [chassisId]/[slotId] operState: [operState]Processor [id] on server [id] operState: [operState]Processor [id] on server [chassisId]/[slotId]/[serverInstanceId] operState: [operState]
Explanation
This fault occurs in the unlikely event that a processor is disabled.
Recommended Action
If you see this fault, take the following actions:
Step 1 If this fault occurs on a blade server, remove and reinsert the server into the chassis.
Step 2 In Cisco UCS Manager, decommission and recommission the blade server.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-disabled
mibFaultName: fltProcessorUnitDisabled
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/cpu-[id]
Affected MO: sys/rack-unit-[id]/board/cpu-[id]
fltMemoryUnitDisabled
Fault Code: F0844
Message
DIMM [location] on server [chassisId]/[slotId] operState: [operState]DIMM [location] on server [id] operaState: [operState]DIMM [location] on server [chassisId]/[slotId]/[serverInstanceId] operState: [operState]
Explanation
This fault is raised when the server BIOS disables a DIMM. The BIOS could disable a DIMM for several reasons, including incorrect location of the DIMM or incompatible speed.
Recommended Action
If you see this fault, refer to the Cisco UCS B-Series Troubleshooting Guide for information on how to resolve the DIMM issues.
Fault Details
Cause: equipment-disabled
mibFaultName: fltMemoryUnitDisabled
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]/mem-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/memarray-[id]/mem-[id]
Affected MO: sys/rack-unit-[id]/board/memarray-[id]/mem-[id]
fltFirmwareBootUnitActivateStatusFailed
Fault Code: F0856
Message
Activation failed and Activate Status set to failed.
Explanation
This fault typically occurs for the following reasons: when firmware activation fails, or if the after activation running image is not the corresponding startup image.
- Firmware activation failed.
- The version of firmware running on the server after activation is not the version listed in Cisco UCS Manager as the startup image.
Recommended Action
If you see this fault, take the following actions:
Step 1 Go to FSM tab for the endpoint on which the fault is raised and review the error description for the reason that the activation failed.
Step 2 If the FSM failed, review the error message in the FSM.
Step 3 If possible, correct the problem described in the error message.
Step 4 If the problem persists, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFirmwareBootUnitActivateStatusFailed
moClass: firmware:BootUnit
Affected MO: capabilities/ep/mgmt-ext/fw-boot-def/bootunit-[type]
Affected MO: capabilities/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/graphics-card-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/onboard-device-[deviceType]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/onboard-device-[deviceType]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/graphics-card-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/onboard-device-[deviceType]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/onboard-device-[deviceType]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/psu-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/sas-expander-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/sas-expander-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/sas-expander-[id]/onboard-device-[deviceType]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/slot-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/onboard-device-[deviceType]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/fex-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/fex-[id]/psu-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/graphics-card-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/onboard-device-[deviceType]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/onboard-device-[deviceType]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/psu-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/switch-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/switch-[id]/psu-[id]/fw-boot-def/bootunit-[type]
fltFabricInternalPcDown
Fault Code: F0858
Message
[type] port-channel [portId] on fabric interconnect [id] oper state: [operState], reason: [stateQual]
Explanation
This fault occurs when the transport VIF for a server is down. Cisco UCS Manager raises this fault when a fabric interconnect reports the connectivity state on virtual interface as one of the following:
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the blade server discovery was successful.
Step 2 Check the states on all communicating ports from end to end.
Step 3 If connectivity seems correct, decommission and recommission the server.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: operational-state-down
mibFaultName: fltFabricInternalPcDown
moClass: fabric:InternalPc
Affected MO: fabric/server/sw-[id]/pc-[portId]
fltMgmtEntityDevice-1-shared-storage-error
Fault Code: F0863
Message
device [chassis1], error accessing shared-storage
Explanation
This fault occurs in an unlikely event that the shared storage selected for writing the cluster state is not accessible. This fault is typically a transient fault. You might see this fault when one of the following occurs: (a) the Fabric Interconnect boots, (b) the IO Module is reset, (c) the rack server is reboot, or (d) system is upgraded/downgraded. If this fault is not cleared after the system returns to normal operation following the reboot/reset/upgrade/downgrade, then it may affect the full HA functionality of the Fabric Interconnect cluster.
Recommended Action
If this fault is not cleared even after the system returns to normal operation, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: device-shared-storage-error
mibFaultName: fltMgmtEntityDevice1SharedStorageError
Affected MO: sys/mgmt-entity-[id]
fltMgmtEntityDevice-2-shared-storage error
Fault Code: F0864
Message
device [chassis2], error accessing shared-storage
Explanation
This fault occurs in an unlikely event that the shared storage selected for writing the cluster state is not accessible. This fault is typically a transient fault. You might see this fault when one of the following occurs: (a) the Fabric Interconnect boots, (b) the IO Module is reset, (c) the rack server is reboot, or (d) system is upgraded/downgraded. If this fault is not cleared after the system returns to normal operation following the reboot/reset/upgrade/downgrade, then it may affect the full HA functionality of the Fabric Interconnect cluster.
Recommended Action
If this fault is not cleared even after the system returns to normal operation, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: device-shared-storage-error
mibFaultName: fltMgmtEntityDevice2SharedStorageError
Affected MO: sys/mgmt-entity-[id]
fltMgmtEntityDevice-3-shared-storage error
Fault Code: F0865
Message
device [chassis3], error accessing shared-storage
Explanation
This fault occurs in an unlikely event that the shared storage selected for writing the cluster state is not accessible. This fault is typically a transient fault. You might see this fault when one of the following occurs: (a) the Fabric Interconnect boots, (b) the IO Module is reset, (c) the rack server is reboot, or (d) system is upgraded/downgraded. If this fault is not cleared after the system returns to normal operation following the reboot/reset/upgrade/downgrade, then it may affect the full HA functionality of the Fabric Interconnect cluster.
Recommended Action
If this fault is not cleared even after the system returns to normal operation, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: device-shared-storage-error
mibFaultName: fltMgmtEntityDevice3SharedStorageError
Affected MO: sys/mgmt-entity-[id]
fltMgmtEntityHa-ssh-keys-mismatched
Fault Code: F0866
Message
Fabric Interconnect [id], management services, mismatched SSH keys
Explanation
This fault indicates that one of the following scenarios has occurred:
- The internal SSH keys used for HA in the cluster configuration are mismatched. This causes certain operations to fail.
- Another fabric interconnect is connected to the primary fabric interconnect in the cluster without first erasing the existing configuration in the primary.
Recommended Action
If you see this fault, take the following actions:
Step 1 Log into the Cisco UCS Manager CLI on the subordinate fabric interconnect.
Step 2 Enter connect local-mgmt
Step 3 Enter erase configuration to erase the configuration on the subordinate fabric interconnect and reboot it.
Step 4 When the secondary fabric interconnect has rebooted, reconfigure it for the cluster.
Step 5 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: ha-ssh-keys-mismatched
mibFaultName: fltMgmtEntityHaSshKeysMismatched
Affected MO: sys/mgmt-entity-[id]
fltMgmtPmonEntryUCSM process failure
Fault Code: F0867
Message
UCSM process [name] failed on FI [switchId]
Explanation
This fault occurs in an unlikely event of a Cisco UCS Manager process crash. Typically, the failed process restarts and recovers from the problem. Any pending operations are restarted after the process successfully restarts.
Recommended Action
If you see this fault and the process does not restart successfully, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: ucsm-process-failure
mibFaultName: fltMgmtPmonEntryUCSMProcessFailure
Affected MO: sys/mgmt-entity-[id]/[name]
fltComputeBoardPowerFail
Fault Code: F0868
Message
Motherboard of server [chassisId]/[slotId] (service profile: [assignedToDn]) power: [power]Motherboard of server [id] (service profile: [assignedToDn]) power: [power]Motherboard of server [chassisId]/[slotId]/[serverInstanceId] (service profile: [assignedToDn]) power: [power]
Explanation
This fault typically occurs when CIMC is unable to turn ON the server power. This may indicate a hardware component failure.
Recommended Action
If you see this fault, take the following actions
Step 1 In case of a blade server, remove the blade server from the chassis and re-insert.
Step 2 In case of a rack server, manually a/c power cycle the server.
Step 3 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltComputeBoardPowerFail
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board
Affected MO: sys/rack-unit-[id]/board
fltComputeABoardThermalProblem
Fault Code: F0869
Message
Motherboard [faultQualifier] of server [chassisId]/[slotId] (service profile: [assignedToDn]) thermal: [thermal]Motherboard of server [id] (service profile: [assignedToDn]) thermal: [thermal]Motherboard [faultQualifier] of server [chassisId]/[slotId]/[serverInstanceId] (service profile: [assignedToDn]) thermal: [thermal]
Explanation
This fault typically occurs when the motherboard thermal sensors on a server detect a problem.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the server fans are working properly.
Step 2 Wait for 24 hours to see if the problem resolves itself.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltComputeABoardThermalProblem
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]
Affected MO: sys/rack-unit-[id]/board
Affected MO: sys/rack-unit-[id]/ext-board-[id]
fltVmVifLinkState
Fault Code: F0876
Message
Virtual interface [vifId] link is down; reason [stateQual]
Explanation
This fault occurs when Cisco UCS cannot send or receive data through an uplink port.
Recommended Action
If you see this fault, take the following actions:
Step 1 Enable the failed uplink port.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltVmVifLinkState
Affected MO: vmm/computeEp-[uuid]/nic-[name]/sw-[phSwitchId]vif-[vifId]
Affected MO: vmm/hv-[uuid]/nic-[name]/sw-[phSwitchId]vif-[vifId]
Affected MO: vmm/vm-[uuid]/nic-[name]/sw-[phSwitchId]vif-[vifId]
fltEquipmentPsuPowerSupplyShutdown
Fault Code: F0881
Message
Power supply [id] in chassis [id] shutdown reason:[powerStateQualifier]
Explanation
This fault typically occurs when a power supply unit in a chassis, fabric interconnect, or a FEX is shut down, either due to higher than expected power current, higher than expected temperatures, or the failure of a fan.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the server.
Step 2 Review the Cisco UCS Site Preparation Guide to ensure the servers have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco UCS chassis or rack server are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Verify that the power cord is properly connected to the PSU and the power source.
Step 7 Verify that the power source is 220 volts.
Step 8 Verify that the PSU is properly installed in the chassis or fabric interconnect.
Step 9 Remove the PSU and reinstall it.
Step 10 Replace the PSU.
Step 11 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentPsuPowerSupplyShutdown
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentPsuPowerThreshold
Fault Code: F0882
Message
Power supply [id] on chassis [id] has exceeded its power thresholdPower supply [id] on server [id] has exceeded its power threshold
Explanation
This fault occurs when a power supply unit is drawing too much current.
Recommended Action
If you see this fault, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentPsuPowerThreshold
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentPsuInputError
Fault Code: F0883
Message
Power supply [id] on chassis [id] has disconnected cable or bad input voltagePower supply [id] on server [id] has disconnected cable or bad input voltage
Explanation
This fault occurs when a power cable is disconnected or input voltage is incorrect.
Recommended Action
If you see this fault, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentPsuInputError
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentSwitchCardPowerOff
Fault Code: F0884
Message
Switch card is powered down.
Explanation
This fault occurs when the switch card is powered down.
Recommended Action
If you see this fault, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentSwitchCardPowerOff
moClass: equipment:SwitchCard
Affected MO: sys/switch-[id]/slot-[id]
fltNetworkElementInventoryFailed
Fault Code: F0885
Message
Fabric Interconnect [id] inventory is not complete [inventoryStatus]
Explanation
Cisco UCS Manager raises this fault when the management subsystem is unable to perform an inventory of the physical components, such as I/O cards or physical ports.
Recommended Action
If you see this fault, take the following actions:
Step 1 Ensure that both fabric interconnects in an HA cluster are running the same software versions.
Step 2 Ensure that the fabric interconnect software is a version that is compatible with the Cisco UCS Manager software.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltNetworkElementInventoryFailed
Affected MO: sys/switch-[id]
fltAdaptorUnitExtnUnidentifiable-fru
Fault Code: F0900
Message
Adapter extension [id] in server [chassisId]/[slotId] has unidentified FRU
Explanation
This fault typically occurs because Cisco UCS Manager has detected an unsupported adapter unit extension, such as a pass-through adaptor. For example, the model, vendor, or revision is not recognized.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that a supported adapter unit extension is installed.
Step 2 Verify that the capability catalog in Cisco UCS Manager is up to date. If necessary, update the catalog.
Step 3 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: unidentifiable-fru
mibFaultName: fltAdaptorUnitExtnUnidentifiableFru
moClass: adaptor:UnitExtn
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/adaptor-extn-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/adaptor-extn-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/adaptor-extn-[id]
fltAdaptorUnitExtnMissing
Fault Code: F0901
Message
Adapter extension [id] in server [chassisId]/[slotId] presence: [presence]
Explanation
This fault typically occurs when an I/O adapter unit extension, such as a pass-through adapter, is missing. Cisco UCS Manager raises this fault when any of the following scenario occur:
- The endpoint reports there is no adapter unit extension, such as a pass-through adapter, plugged into the adapter slot.
- The endpoint cannot detect or communicate with the adapter unit extension plugged into the adapter slot.
Recommended Action
If you see this fault, take the following actions:
Step 1 Ensure the adapter unit extension is properly plugged into an adapter slot in the server.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltAdaptorUnitExtnMissing
moClass: adaptor:UnitExtn
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/adaptor-extn-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/adaptor-extn-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/adaptor-extn-[id]
fltEquipmentFexFex-unsupported
Fault Code: F0902
Message
Fex [id] with model [model] is unsupported
Explanation
This fault typically occurs because Cisco UCS Manager has detected an unsupported FEX. For example, the model, vendor, or revision is not recognized.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that a supported FEX is installed.
Step 2 Verify that the capability catalog in Cisco UCS Manager is up to date. If necessary, update the catalog.
Step 3 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentFexFexUnsupported
Affected MO: sys/fex-[id]
fltVnicIScsiConfig-failed
Fault Code: F0903
Message
iSCSI vNIC [name], service profile [name] has duplicate iqn name [initiatorName]
Explanation
This fault typically occurs when IScsi Vnics refer the same iqn name.
Recommended Action
If you see this fault, take the following actions:
Step 1 Make sure that iqn name unique per iSCSI vnic.
Step 2 Using show identity iqn check if the iSCSI vnic is registered in the universe.
Step 3 Try non disruptive actions such as changing description on the Service Profile to register the iqn in the universe.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: configuration-failed
mibFaultName: fltVnicIScsiConfigFailed
Affected MO: org-[name]/ls-[name]/iscsi-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/iscsi-[name]
fltPkiKeyRingStatus
Fault Code: F0909
Message
[name] Keyring’s certificate is invalid, reason: [certStatus].
Explanation
This fault occurs when certificate status of Keyring has become invalid.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
Cause: invalid-keyring-certificate
mibFaultName: fltPkiKeyRingStatus
Affected MO: sys/pki-ext/keyring-[name]
fltPkiTPStatus
Fault Code: F0910
Message
[name] Trustpoint’s cert-chain is invalid, reason: [certStatus].
Explanation
This fault occurs when certificate status of TrustPoint has become invalid.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
Cause: invalid-trustpoint-cert-chain
mibFaultName: fltPkiTPStatus
Affected MO: sys/pki-ext/tp-[name]
fltComputePhysicalDisassociationFailed
Fault Code: F0915
Message
Failed to disassociate server [id]Failed to disassociate server [chassisId]/[slotId]Failed to disassociate server [chassisId]/[slotId]/[serverInstanceId]
Explanation
This fault typically occurs for one of the following reasons:
- The server is down.
- The data path is not working.
- Cisco UCS Manager cannot communicate with one or more of the fabric interconnect, the server, or a component on the server.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the communication path to the server including fabric interconnect server ports, IOM link and the current state of the server
Step 2 If the server is stuck in an inappropriate state, such as booting, power cycle the server.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: disassociation-failed
mibFaultName: fltComputePhysicalDisassociationFailed
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalNetworkMisconfigured
Fault Code: F0916
Message
Server [id] (service profile: [assignedToDn]) has mis-configured network vif resourcesServer [chassisId]/[slotId] (service profile: [assignedToDn]) has mis-configured network vif resourcesServer [chassisId]/[slotId]/[serverInstanceId] (service profile: [assignedToDn]) has mis-configured network vif resources
Explanation
This fault would occur when UCSM VIF-id Map is not the same as the VIF-id map deployed on the adaptor upon Full Backup-Restore etc.
Recommended Action
If you see this fault, take the following actions:
Step 1 Re-acknowledge the server. This will trigger Deep Discovery-Deep Association & will resolve the issue
Step 2 If the above actions did not resolve the issue, execute the show tech-support command and contact Cisco Technical Support.
Fault Details
mibFaultName: fltComputePhysicalNetworkMisconfigured
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltVnicProfileProfileConfigIncorrect
Fault Code: F0917
Message
The Port Profile [name] has an invalid configuration.
Explanation
This fault occurs there is an invalid entry for a port profile configuration.
Recommended Action
Check documentation and correct the offending entry in the port profile configuration.
Fault Details
Cause: profile-config-incorrect
mibFaultName: fltVnicProfileProfileConfigIncorrect
Affected MO: fabric/lan/profiles/vnic-[name]
fltComputeABoardMotherBoardVoltageThresholdUpperNonRecoverable
Fault Code: F0918
Message
Motherboard input voltage in server [id] is [voltage]Motherboard [faultQualifier] input voltage in server [chassisId]/[slotId] is [voltage]Motherboard input voltage(12V/5V/3V) in server [chassisId]/[slotId]/[serverInstanceId] is [voltage]
Explanation
This fault is raised when one or more motherboard input voltages has become too high and is unlikely to recover.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltComputeABoardMotherBoardVoltageThresholdUpperNonRecoverable
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]
Affected MO: sys/rack-unit-[id]/board
Affected MO: sys/rack-unit-[id]/ext-board-[id]
fltComputeABoardMotherBoardVoltageThresholdLowerNonRecoverable
Fault Code: F0919
Message
Motherboard input voltage in server [id] is [voltage]Motherboard [faultQualifier] input voltage in server [chassisId]/[slotId] is [voltage]Motherboard input voltage(12V/5V/3V) in server [chassisId]/[slotId]/[serverInstanceId] is [voltage]
Explanation
This fault is raised when one or more motherboard input voltages has dropped too low and is unlikely to recover.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltComputeABoardMotherBoardVoltageThresholdLowerNonRecoverable
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]
Affected MO: sys/rack-unit-[id]/board
Affected MO: sys/rack-unit-[id]/ext-board-[id]
fltComputeABoardMotherBoardVoltageUpperThresholdCritical
Fault Code: F0920
Message
Motherboard input voltage in server [id] is [voltage]Motherboard [faultQualifier] input voltage in server [chassisId]/[slotId] is [voltage]Motherboard input voltage(12V/5V/3V) in server [chassisId]/[slotId]/[serverInstanceId] is [voltage]
Explanation
This fault is raised when one or more motherboard input voltages has crossed upper critical thresholds.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltComputeABoardMotherBoardVoltageUpperThresholdCritical
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]
Affected MO: sys/rack-unit-[id]/board
Affected MO: sys/rack-unit-[id]/ext-board-[id]
fltComputeABoardMotherBoardVoltageLowerThresholdCritical
Fault Code: F0921
Message
Motherboard input voltage in server [id] is [voltage]Motherboard [faultQualifier] input voltage in server [chassisId]/[slotId] is [voltage]Motherboard [faultQualifier] input voltage(12V/5V/3V) in server [chassisId]/[slotId]/[serverInstanceId] is [voltage]
Explanation
This fault is raised when one or more motherboard input voltages has crossed lower critical thresholds.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltComputeABoardMotherBoardVoltageLowerThresholdCritical
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]
Affected MO: sys/rack-unit-[id]/board
Affected MO: sys/rack-unit-[id]/ext-board-[id]
fltVnicEtherIfVlanAccessFault
Fault Code: F0932
Message
The named vlan [name] for vNIC [name] cannot be accessed from org [name]
Explanation
This fault typically occurs when a Service Profile’s vnic interface (LAN) is resolvable but the service profile does not have access to the vlan. In this case, the default vlan will be used.
Recommended Action
This fault will be removed if you perform one of the following actions:
Step 1 Change the vnic’s interface name to a VLAN that you have access to.
Step 2 If you wish to use the default vlan, change the vnic’s interface name to default.
Step 3 Configure access to the named vlan by creating a vlan permit or vlan group permit in the service profile’s org (or a parent org).
Fault Details
Cause: inaccessible-vlan-referenced
mibFaultName: fltVnicEtherIfVlanAccessFault
Affected MO: fabric/lan/network-sets/fabric-network-[name]/fabric-network-def-[name]/vm-network-def-[name]/if-[name]
Affected MO: fabric/lan/profiles/vnic-[name]/if-[name]
Affected MO: fabric/lanmon/eth-flow-monitoring/flow-exporter-profile-[name]/if-[name]
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/lan-conn-templ-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/ipc-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ipc-[name]/if-[name]
fltVnicEtherIfVlanUnresolvable
Fault Code: F0933
Message
The named vlan [name] for vNIC [name] cannot be resolved
Explanation
This fault (warning) occurs when a Service Profile’s vnic interface (LAN) is unresolvable. In this case, the default vlan will be used as the operational vlan.
Recommended Action
This fault will be removed if you perform one of the following actions:
Step 1 Change the vnic interface name to an existing VLAN.
Step 2 Create the named vlan.
Fault Details
Cause: referenced-vlan-unresolvable
mibFaultName: fltVnicEtherIfVlanUnresolvable
Affected MO: fabric/lan/network-sets/fabric-network-[name]/fabric-network-def-[name]/vm-network-def-[name]/if-[name]
Affected MO: fabric/lan/profiles/vnic-[name]/if-[name]
Affected MO: fabric/lanmon/eth-flow-monitoring/flow-exporter-profile-[name]/if-[name]
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/lan-conn-templ-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/ipc-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ipc-[name]/if-[name]
fltVnicEtherIfInvalidVlan
Fault Code: F0934
Message
Invalid Vlan in the allowed vlan list
Explanation
This fault typically occurs when a vnic of a service profile or a port profile contains an invalid vlan. an invalid vlan can be any one of the following:
Step 1 an isolated vlan or a community vlan that is not associated to a valid primary vlan
Step 2 a primary vlan without any of its assoicated secondary vlans allowed on the vnic
Step 3 a vlan which has sharing-type or primary vlan name not matching to that of vlan in lan-side/appliance-side
Step 4 a vlan which overlaps with FCoE vlan
Recommended Action
This fault will be removed if you perform one of the following actions:
Step 1 if invalid vlan is an isolated or community vlan then make sure it is mapped to a valid primary vlan.
Step 2 if invalid vlan is a primary vlan then either allow any of its secondary vlans or delete it from vnic or port profile.
Step 3 if invalid vlan is a vlan that does not match the sharing properties with the vlan of same vlan id in the lan-side/appliance-side, change the properties of this vlan to be the same as the other.
Step 4 if invalid vlan is a vlan overlaps with FCoE vlan then configure a different vlan.
Fault Details
Cause: invalid-vlan-in-the-allowed-vlan-list
mibFaultName: fltVnicEtherIfInvalidVlan
Affected MO: fabric/lan/network-sets/fabric-network-[name]/fabric-network-def-[name]/vm-network-def-[name]/if-[name]
Affected MO: fabric/lan/profiles/vnic-[name]/if-[name]
Affected MO: fabric/lanmon/eth-flow-monitoring/flow-exporter-profile-[name]/if-[name]
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/lan-conn-templ-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/ipc-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ipc-[name]/if-[name]
fltFabricVlanVlanConflictPermit
Fault Code: F0935
Message
There are multiple vlans with id [id] have different accessability configured.
Explanation
This fault occurs when multipl global vlans with the same id have different access configurations.
Recommended Action
Change the access configuration by configuring VLAN/VLAN Group Permits.
Fault Details
Cause: vlan-conflict-permit
mibFaultName: fltFabricVlanVlanConflictPermit
Affected MO: fabric/eth-estc/[id]/net-[name]
Affected MO: fabric/eth-estc/net-[name]
Affected MO: fabric/lan/[id]/net-[name]
Affected MO: fabric/lan/net-[name]
fltFabricVlanReqVlanPermitUnresolved
Fault Code: F0936
Message
The VLAN permit does not reference any existing vlans.
Explanation
This fault occurs when a VLAN permit exists but there are no vnics by the name.
Recommended Action
Delete the VLAN permit, create the referenced VLAN (or ignore).
Fault Details
Cause: vlan-permit-unresolved
mibFaultName: fltFabricVlanReqVlanPermitUnresolved
Affected MO: org-[name]/vlan-req-[name]
fltFabricVlanGroupReqVlanGroupPermitUnresolved
Fault Code: F0937
Message
The VLAN permit does not reference any existing net groups.
Explanation
This fault occurs when a VLAN group permit exists but there are no referenced network groups.
Recommended Action
Delete the VLAN permit, create the referenced VLAN (or ignore).
Fault Details
Cause: group-permit-unresolved
mibFaultName: fltFabricVlanGroupReqVlanGroupPermitUnresolved
moClass: fabric:VlanGroupReq
Affected MO: org-[name]/vlan-group-req-[name]
fltExtpolClientClientLostConnectivity
Fault Code: F0988
Message
UCS has lost connectivity with UCS Central
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
Cause: client-lost-connectivity
mibFaultName: fltExtpolClientClientLostConnectivity
Affected MO: extpol/reg/clients/client-[id]
fltStorageLocalDiskDegraded
Fault Code: F0996
Message
Local disk [id] on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]Local disk [id] on server [id] operability: [operability]. Reason: [operQualifierReason]Local disk [id] on storage enclosure [id] operability: [operability]. Reason: [operQualifierReason]Local disk [id] on chassis [id] operability: [operability]. Reason: [operQualifierReason]
Explanation
This fault occurs when the local disk has become degraded. The fault description will contain the physical drive state, which indicates the reason for the degradation.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the drive state is "rebuild" or "copyback", wait for the rebuild or copyback operation to complete.
Step 2 If the drive state is "predictive-failure", replace the disk.
Fault Details
Cause: equipment-degraded
mibFaultName: fltStorageLocalDiskDegraded
moClass: storage:LocalDisk
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]
fltStorageRaidBatteryDegraded
Fault Code: F0997
Message
RAID Battery on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]RAID Battery on server [id] operability: [operability]. Reason: [operQualifierReason]RAID Battery on chassis [id] operability: [operability]. Reason: [operQualifierReason]
Explanation
This fault occurs when the RAID backup unit is degraded.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the fault reason indicates the backup unit is in a relearning cycle, wait for relearning to complete.
Step 2 If the fault reason indicates the backup unit is about to fail, replace the backup unit.
Step 3 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-degraded
mibFaultName: fltStorageRaidBatteryDegraded
moClass: storage:RaidBattery
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/raid-battery
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/raid-battery
Affected MO: sys/chassis-[id]/storage-[type]-[id]/raid-battery
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/raid-battery
fltStorageRaidBatteryRelearnAborted
Fault Code: F0998
Message
RAID Battery on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]RAID Battery on server [id] operability: [operability]. Reason: [operQualifierReason]RAID Battery on chassis [id] operability: [operability]. Reason: [operQualifierReason]
Explanation
NOTE: This fault is not currently implemented by UCSMThis fault is present only as a placeholder, possibly for another release,such as stand-alone rack servers.---This fault occurs when the backup unit’s relearning cycle was aborted.
Recommended Action
If you see this fault, take the following actions:
Step 1 Retry the learn cycle.
Step 2 Replace the backup unit.
Fault Details
Cause: equipment-degraded
mibFaultName: fltStorageRaidBatteryRelearnAborted
moClass: storage:RaidBattery
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/raid-battery
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/raid-battery
Affected MO: sys/chassis-[id]/storage-[type]-[id]/raid-battery
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/raid-battery
fltStorageRaidBatteryRelearnFailed
Fault Code: F0999
Message
RAID Battery on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]RAID Battery on server [id] operability: [operability]. Reason: [operQualifierReason]RAID Battery on chassis [id] operability: [operability]. Reason: [operQualifierReason]
Explanation
NOTE: This fault is not currently implemented by UCSMThis fault is present only as a placeholder, possibly for another release,such as stand-alone rack servers.---This fault occurs when the backup unit’s relearning cycle has failed.
Recommended Action
If you see this fault, take the following actions:
Step 1 Retry the learn cycle.
Step 2 Replace the backup unit.
Fault Details
Cause: equipment-degraded
mibFaultName: fltStorageRaidBatteryRelearnFailed
moClass: storage:RaidBattery
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/raid-battery
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/raid-battery
Affected MO: sys/chassis-[id]/storage-[type]-[id]/raid-battery
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/raid-battery
fltStorageADefConfiguration-error
Fault Code: F1000
Message
Vsan trunking is not supported on Vhbas. Targets with overlapping path should have same vsan.
Explanation
Under a storage connection policy, storage targets with overlapping path setting should have similar VSAN setting.
Recommended Action
If you see this fault, take the following action:
Step 1 Under the storage connection policy find out the targets with overlapping path setting. Make sure that same VSAN is applied on these targets.
Fault Details
Cause: configuration-error
mibFaultName: fltStorageADefConfigurationError
Affected MO: org-[name]/ls-[name]/grp-[name]/fc-group/storage-conndef
Affected MO: org-[name]/san-conn-pol-[name]/grp-[name]/fc-group/storage-conndef
Affected MO: org-[name]/storage-connpolicy-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/grp-[name]/fc-group/storage-conndef
fltStorageInitiatorConfiguration-error
Fault Code: F1001
Message
Initiator [name] either cannot be resolved or does not match with one of the storage targets. No zones are deployed for this initiator and the target.
Explanation
Initiator either cannot be resolved or does not match with one of the targets.
Recommended Action
If you see this fault, take the following action:
Step 1 Check if vhba interface referenced by this Initiator exsits.
Step 2 Check if switch id or vsan name of the vhba interface referenced by this Initiator matches one of the targets.
Fault Details
Cause: configuration-error
mibFaultName: fltStorageInitiatorConfigurationError
moClass: storage:Initiator
Affected MO: org-[name]/ls-[name]/grp-[name]/ini-[name]
Affected MO: org-[name]/san-conn-pol-[name]/grp-[name]/ini-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/grp-[name]/ini-[name]
fltStorageVsanRefVsanUnresolvable
Fault Code: F1002
Message
The named vsan [name] for storage target cannot be resolved
Explanation
This fault (warning) occurs when a Storage Target’s vsan interface (VSAN) is unresolvable. In this case, the default vsan will be used as the operational vsan.
Recommended Action
This fault will be removed if you perform one of the following actions:
Step 1 Change the vsan reference name to an existing VSAN.
Step 2 Create the named vsan.
Fault Details
Cause: referenced-vsan-unresolvable
mibFaultName: fltStorageVsanRefVsanUnresolvable
Affected MO: fabric/fc-estc/zone-profile-[name]/zone-[name]/vsan-ref
Affected MO: org-[name]/ls-[name]/grp-[name]/fc-group/storage-conndef/fc-target-ep-[targetwwpn]/vsan-ref
Affected MO: org-[name]/san-conn-pol-[name]/grp-[name]/fc-group/storage-conndef/fc-target-ep-[targetwwpn]/vsan-ref
Affected MO: org-[name]/storage-connpolicy-[name]/fc-target-ep-[targetwwpn]/vsan-ref
Affected MO: org-[name]/tier-[name]/ls-[name]/grp-[name]/fc-group/storage-conndef/fc-target-ep-[targetwwpn]/vsan-ref
fltStorageControllerPatrolReadFailed
Fault Code: F1003
Message
Controller [id] on server [chassisId]/[slotId] had a patrol read failure. Reason: [operQualifierReason]Controller [id] on server [id] had a patrol read failure. Reason: [operQualifierReason]Controller [id] on chassis [id] had a patrol read failure. Reason: [operQualifierReason]
Explanation
NOTE: This fault is not currently implemented by UCSMThis fault is present only as a placeholder, possibly for another release,such as stand-alone rack servers.---This fault occurs when a Patrol Read operation has failed.
Recommended Action
Re-run the patrol read operation.
Fault Details
mibFaultName: fltStorageControllerPatrolReadFailed
moClass: storage:Controller
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]
fltStorageControllerInoperable
Fault Code: F1004
Message
Controller [id] on server [chassisId]/[slotId] is inoperable. Reason: [operQualifierReason]Controller [id] on server [id] is inoperable. Reason: [operQualifierReason]Controller [id] on chassis [id] is inoperable. Reason: [operQualifierReason]
Explanation
This fault occurs when the storage controller is inaccessible.
Recommended Action
If you see this fault, take the following action:
Step 1 Create a show tech-support file and contact Cisco TAC.
Step 2 It is possible that the PCI and mezz-based storage controllers requires to be reseated or replaced. Consider these actions only after contacting Cisco TAC.
Fault Details
Cause: equipment-inoperable
mibFaultName: fltStorageControllerInoperable
moClass: storage:Controller
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]
fltStorageLocalDiskRebuildFailed
Fault Code: F1005
Message
Local disk [id] on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]Local disk [id] on server [id] operability: [operability]. Reason: [operQualifierReason]Local disk [id] on storage enclosure [id] operability: [operability]. Reason: [operQualifierReason]Local disk [id] on chassis [id] operability: [operability]. Reason: [operQualifierReason]
Explanation
NOTE: This fault is not currently implemented by UCSMThis fault is present only as a placeholder, possibly for another release,such as stand-alone rack servers.---This fault occurs when a rebuild operation has failed. This may cause a degradation in performance.
Recommended Action
If you see this fault, take the following action:
Step 1 Retry the rebuild operation.
Step 2 Replace the disk.
Fault Details
mibFaultName: fltStorageLocalDiskRebuildFailed
moClass: storage:LocalDisk
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]
fltStorageLocalDiskCopybackFailed
Fault Code: F1006
Message
Local disk [id] on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]Local disk [id] on server [id] operability: [operability]. Reason: [operQualifierReason]Local disk [id] on storage enclosure [id] operability: [operability]. Reason: [operQualifierReason]Local disk [id] on chassis [id] operability: [operability]. Reason: [operQualifierReason]
Explanation
NOTE: This fault is not currently implemented by UCSMThis fault is present only as a placeholder, possibly for another release,such as stand-alone rack servers.---This fault occurs when a copyback operation has failed. This may cause a degradation in performance.
Recommended Action
If you see this fault, take the following action:
Step 1 Retry the copyback operation.
Step 2 Replace the disk.
Fault Details
mibFaultName: fltStorageLocalDiskCopybackFailed
moClass: storage:LocalDisk
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]
fltStorageVirtualDriveInoperable
Fault Code: F1007
Message
Virtual drive [id] on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]Virtual drive [id] on server [id] operability: [operability]. Reason: [operQualifierReason]Virtual drive [id] on chassis [id] operability: [operability]. Reason: [operQualifierReason]
Explanation
This fault occurs when the virtual drive has become inoperable.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify the presence and health of disks that are used by the virtual drive.
Step 2 Create a show tech-support file and contact Cisco TAC.
Step 3 It is possible that the disks require to be reseated or replaced. Consider these actions only after contacting Cisco TAC.
Fault Details
Cause: equipment-inoperable
mibFaultName: fltStorageVirtualDriveInoperable
moClass: storage:VirtualDrive
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/vd-container-[id]/vd-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/vd-container-[id]/vd-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/vd-[id]
Affected MO: sys/chassis-[id]/vd-container-[id]/vd-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/rack-unit-[id]/vd-container-[id]/vd-[id]
fltStorageVirtualDriveDegraded
Fault Code: F1008
Message
Virtual drive [id] on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]Virtual drive [id] on server [id] operability: [operability]. Reason: [operQualifierReason]Virtual drive [id] on chassis [id] operability: [operability]. Reason: [operQualifierReason]
Explanation
This fault occurs when the virtual drive has become degraded. The fault description will contain the physical drive state, which indicates the reason for the degradation.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the drive is performing a consistency check operation, wait for the operation to complete.
Step 2 Verify the presence and health of disks that are used by the virtual drive.
Step 3 If applicable, reseat or replace used disks.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-degraded
mibFaultName: fltStorageVirtualDriveDegraded
moClass: storage:VirtualDrive
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/vd-container-[id]/vd-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/vd-container-[id]/vd-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/vd-[id]
Affected MO: sys/chassis-[id]/vd-container-[id]/vd-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/rack-unit-[id]/vd-container-[id]/vd-[id]
fltStorageVirtualDriveReconstructionFailed
Fault Code: F1009
Message
Virtual drive [id] on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]Virtual drive [id] on server [id] operability: [operability]. Reason: [operQualifierReason]Virtual drive [id] on chassis [id] operability: [operability]. Reason: [operQualifierReason]
Explanation
NOTE: This fault is not currently implemented by UCSMThis fault is present only as a placeholder, possibly for another release,such as stand-alone rack servers.---This fault occurs when a drive reconstruction operation has failed. This may cause a degradation in performance.
Recommended Action
If you see this fault, take the following action:
Step 1 Retry the reconstruction operation.
Step 2 Delete and recreate the virtual drive.
Fault Details
Cause: equipment-degraded
mibFaultName: fltStorageVirtualDriveReconstructionFailed
moClass: storage:VirtualDrive
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/vd-container-[id]/vd-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/vd-container-[id]/vd-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/vd-[id]
Affected MO: sys/chassis-[id]/vd-container-[id]/vd-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/rack-unit-[id]/vd-container-[id]/vd-[id]
fltStorageVirtualDriveConsistencyCheckFailed
Fault Code: F1010
Message
Virtual drive [id] on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]Virtual drive [id] on server [id] operability: [operability]. Reason: [operQualifierReason]Virtual drive [id] on chassis [id] operability: [operability]. Reason: [operQualifierReason]
Explanation
NOTE: This fault is not currently implemented by UCSMThis fault is present only as a placeholder, possibly for another release,such as stand-alone rack servers.---This fault occurs when a drive consistency check operation has failed. This may cause a degradation in performance.
Recommended Action
If you see this fault, take the following action:
Step 1 Retry the consistency check operation.
Step 2 Delete and recreate the virtual drive.
Fault Details
Cause: equipment-degraded
mibFaultName: fltStorageVirtualDriveConsistencyCheckFailed
moClass: storage:VirtualDrive
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/vd-container-[id]/vd-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/vd-container-[id]/vd-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/vd-[id]
Affected MO: sys/chassis-[id]/vd-container-[id]/vd-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/rack-unit-[id]/vd-container-[id]/vd-[id]
fltAaaProviderGroupProvidergroup
Fault Code: F1026
Message
For [dn]: Server Group with name [name] already exist, You need to specify a unique name for this object.
Explanation
This fault typically occurs because Cisco UCS Manager has detected multiple provider-groups with same name.
Recommended Action
If you see this fault, take the following actions:
Step 1 Need to delete the duplicate provider group configured causing this problem.
Fault Details
Cause: provider-group-already-exists
mibFaultName: fltAaaProviderGroupProvidergroup
moClass: aaa:ProviderGroup
Affected MO: sys/ldap-ext/providergroup-[name]
Affected MO: sys/radius-ext/providergroup-[name]
Affected MO: sys/tacacs-ext/providergroup-[name]
fltAaaConfigServergroup
Fault Code: F1027
Message
For [dn]: [realm] Server Group with name [providerGroup] doesn’t exist or is not deployed.
Explanation
This fault typically occurs because Cisco UCS Manager has detected an unsupported authentication method.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that server group configured for authentication is present.
Step 2 If the server group is not configured, create the server group to use for authentication.
Fault Details
Cause: invalid-server-group
mibFaultName: fltAaaConfigServergroup
Affected MO: sys/auth-realm/console-auth
Affected MO: sys/auth-realm/default-auth
Affected MO: sys/auth-realm/domain-[name]/domain-auth
fltAaaRoleRoleNotDeployed
Fault Code: F1028
Message
Role [name] can’t be deployed. Error: [configStatusMessage]
Explanation
This fault typically occurs because Cisco UCS Manager has detected an unsupported role.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that total number of roles is less than maximum supported roles.
Step 2 Verify that sum of privileges across all roles is less than maximum privileges sum.
Fault Details
mibFaultName: fltAaaRoleRoleNotDeployed
Affected MO: sys/user-ext/role-[name]
fltAaaLocaleLocaleNotDeployed
Fault Code: F1029
Message
Locale [name] can’t be deployed. Error: [configStatusMessage]
Explanation
This fault typically occurs because Cisco UCS Manager has detected an unsupported locale.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that total number of locale is less than maximum supported roles.
Fault Details
Cause: locale-config-error
mibFaultName: fltAaaLocaleLocaleNotDeployed
Affected MO: sys/user-ext/locale-[name]
fltAaaUserRoleUserRoleNotDeployed
Fault Code: F1030
Message
For user: [name] role [name] can’t be assigned. Error: [configStatusMessage].For Ldap Group: [name] role [name] can’t be assigned. Error: [configStatusMessage].
Explanation
This fault typically occurs because Cisco UCS Manager has detected an unsupported user role for ldap groups or local users.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the role is present.
Step 2 Verify that the role is applied.
Step 3 Verify that the role is compatible with locales assigned to ldap group or local user.
Fault Details
Cause: user-role-config-error
mibFaultName: fltAaaUserRoleUserRoleNotDeployed
Affected MO: sys/ldap-ext/ldapgroup-[name]/role-[name]
Affected MO: sys/user-ext/remoteuser-[name]/role-[name]
Affected MO: sys/user-ext/user-[name]/role-[name]
fltAaaUserLocaleUserLocaleNotDeployed
Fault Code: F1031
Message
For user: [name] locale [name] can’t be assigned. Error: [configStatusMessage].For Ldap Group: [name] locale [name] can’t be assigned. Error: [configStatusMessage].
Explanation
This fault typically occurs because Cisco UCS Manager has detected an unsupported user locale for ldap groups or local users.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the locale is present.
Step 2 Verify that the locale is applied.
Step 3 Verify that the locale is compatible with roles assigned to ldap group or local user.
Fault Details
Cause: user-locale-config-error
mibFaultName: fltAaaUserLocaleUserLocaleNotDeployed
Affected MO: sys/ldap-ext/ldapgroup-[name]/locale-[name]
Affected MO: sys/user-ext/remoteuser-[name]/locale-[name]
Affected MO: sys/user-ext/user-[name]/locale-[name]
fltPkiKeyRingKeyRingNotDeployed
Fault Code: F1032
Message
Keyring [name] can’t be deployed. Error: [configStatusMessage]
Explanation
This fault typically occurs because Cisco UCS Manager has detected an invalid Keyring.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the trust point configured for this keyring is present.
Step 2 Verify that the trust point found above is applied.
Fault Details
Cause: keyring-config-error
mibFaultName: fltPkiKeyRingKeyRingNotDeployed
Affected MO: sys/pki-ext/keyring-[name]
fltCommSnmpSyscontactEmpty
Fault Code: F1033
Message
UCS Manager cannot deploy an empty value of SNMP Syscontact when Callhome is enabled. The previous value [sysContact] for SNMP Syscontact has been retained.
Explanation
This fault typically occurs when UCS Manager receives an invalid configuration from UCS Central wherein SNMP Syscontact is set to empty when Callhome is enabled.
Recommended Action
If you see this fault, please ensure that the SNMP Syscontact field on UCS Central is configured correctly for the domain group corresponding to this UCSM.
Fault Details
mibFaultName: fltCommSnmpSyscontactEmpty
Affected MO: sys/svc-ext/snmp-svc
fltCommDateTimeCommTimeZoneInvalid
Fault Code: F1034
Message
Timezone:[timezone] is invalid
Explanation
This fault typically occurs because Cisco UCS Manager has detected an unsupported role.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that total number of roles is less than maximum supported roles.
Step 2 Verify that sum of privileges across all roles is less than maximum privileges sum.
Fault Details
Cause: timezone-file-not-exists
mibFaultName: fltCommDateTimeCommTimeZoneInvalid
Affected MO: org-[name]/comm-pol-[name]/datetime-svc
Affected MO: sys/svc-ext/datetime-svc
fltAaaUserLocalUserNotDeployed
Fault Code: F1035
Message
Local User [name] can’t be deployed. Error: [configStatusMessage]
Explanation
This fault typically occurs because Cisco UCS Manager has detected an invalid system user.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that local user name is not used by snmp users.
Fault Details
mibFaultName: fltAaaUserLocalUserNotDeployed
Affected MO: sys/user-ext/user-[name]
fltCommSnmpUserSnmpUserNotDeployed
Fault Code: F1036
Message
SNMP User [name] can’t be deployed. Error: [configStatusMessage]
Explanation
This fault typically occurs because Cisco UCS Manager has detected an invalid snmp user.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that snmp user name is not used by system users.
Fault Details
Cause: snmp-user-config-error
mibFaultName: fltCommSnmpUserSnmpUserNotDeployed
Affected MO: sys/svc-ext/snmp-svc/snmpv3-user-[name]
fltCommSvcEpCommSvcNotDeployed
Fault Code: F1037
Message
Communication Service configuration can’t be deployed. Error: [configStatusMessage]
Explanation
This fault typically occurs because Cisco UCS Manager has detected an invalid communication policy confiuration.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that ports configured across all communication services is unique.
Fault Details
Cause: comm-svc-config-error
mibFaultName: fltCommSvcEpCommSvcNotDeployed
fltComputeABoardPowerUsageProblem
Fault Code: F1040
Message
Motherboard [faultQualifier] of server [chassisId]/[slotId] (service profile: [assignedToDn]) powerUsage: [powerUsage]Motherboard of server [id] (service profile: [assignedToDn]) powerUsage: [powerUsage]Motherboard [faultQualifier] of server [chassisId]/[slotId]/[serverInstanceId] (service profile: [assignedToDn]) powerUsage: [powerUsage]
Explanation
This fault typically occurs when the motherboard power consumption exceeds certain threshold limits. At that time the power usage sensors on a server detect a problem.
Recommended Action
If you see this fault, take the following actions:
Step 1 Create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltComputeABoardPowerUsageProblem
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]
Affected MO: sys/rack-unit-[id]/board
Affected MO: sys/rack-unit-[id]/ext-board-[id]
fltSwVlanPortNsVLANCompNotSupport
Fault Code: F1056
Message
VLAN Port Count Optimization is not supported
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
Cause: no-vlan-optimization
mibFaultName: fltSwVlanPortNsVLANCompNotSupport
Affected MO: sys/switch-[id]/vlan-port-ns
fltPolicyControlEpSuspendModeActive
Fault Code: F1057
Message
UCSM is suspended from receiving updates from UCS Central.
Explanation
This fault occurs when UCSM enters into suspend state from receiving updates from UCS Central that it is registered with.
Recommended Action
If you see this fault, take the following actions:
Step 1 Please check if UCS Central is restored to a previous version or a policy roll-back has occured. You may have brought UCS in to manual suspension mode by using set suspendstate on command under the system-control-ep policy scope.
Step 2 Please confirm the suspend state by using show control-ep policy detail under system scope. If you still want to receive the updates from UCS Central, you need to restore it back to a version compatible with UCSM or set the suspend state to off by acknowledging it by using set ackstate acked under policy-control scope.
Step 3 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: suspend-mode-entered
mibFaultName: fltPolicyControlEpSuspendModeActive
moClass: policy:ControlEp
Affected MO: sys/control-ep-[type]
fltNetworkElementThermalThresholdCritical
Fault Code: F1080
Message
Fabric Interconnect [id] temperature: [thermal]
Explanation
This fault occurs when the temperature of a Fabric Interconnect exceeds a critical threshold value. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco UCS equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment.
- Cisco UCS equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the Fabric Interconnect.
Step 2 Review the Cisco UCS Site Preparation Guide to ensure the Fabric Interconnects have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 6 Replace faulty Fabric Interconnects.
Step 7 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltNetworkElementThermalThresholdCritical
Affected MO: sys/switch-[id]
fltFabricFcoeSanPcEpDown
Fault Code: F1081
Message
[type] Member [slotId]/[aggrPortId]/[portId] of Port-Channel [portId] on fabric interconnect [id] is down, membership: [membership][type] Member [slotId]/[portId] of Port-Channel [portId] on fabric interconnect [id] is down, membership: [membership]
Explanation
This fault typically occurs when a member port in a FCoE uplink port channel is down.
Recommended Action
If you see this fault, take the following action:
Step 1 Check the link connectivity on the upstream switch
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFabricFcoeSanPcEpDown
moClass: fabric:FcoeSanPcEp
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
fltFabricFcoeSanEpDown
Fault Code: F1082
Message
FCoE uplink port [slotId]/[aggrPortId]/[portId] is downFCoE uplink port [slotId]/[portId] is down
Explanation
This fault typically occurs when a Fcoe uplink port is down.
Recommended Action
If you see this fault, take the following action:
Step 1 Check the link connectivity on the upstream switch
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFabricFcoeSanEpDown
moClass: fabric:FcoeSanEp
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
fltFabricVsanMembershipDown
Fault Code: F1083
Message
FCoE or FC uplink is down on Vsan [vsanId]
Explanation
This fault occurs when a particular vsan member of an FCoE uplink is down.
Recommended Action
If you see this fault, take the following action:
Step 1 Check if the vsan is created at the peer switch and check the link connectivity on the upstream switch
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFabricVsanMembershipDown
moClass: fabric:VsanMembership
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/vsanmember-[vsanId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/vsanmember-[vsanId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/vsanmember-[vsanId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/vsanmember-[vsanId]
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]/vsanmember-[vsanId]
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/vsanmember-[vsanId]
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/vsanmember-[vsanId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/vsanmember-[vsanId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/vsanmember-[vsanId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/vsanmember-[vsanId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/vsanmember-[vsanId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/vsanmember-[vsanId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/vsanmember-[vsanId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/vsanmember-[vsanId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/vsanmember-[vsanId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/vsanmember-[vsanId]
Affected MO: fabric/san/[id]/pc-[portId]/vsanmember-[vsanId]
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]/vsanmember-[vsanId]
Affected MO: fabric/san/[id]/phys-slot-[slotId]-port-[portId]/vsanmember-[vsanId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/vsanmember-[vsanId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/vsanmember-[vsanId]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/vsanmember-[vsanId]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/vsanmember-[vsanId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/vsanmember-[vsanId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/vsanmember-[vsanId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/vsanmember-[vsanId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/vsanmember-[vsanId]
fltFabricFcoeSanEpUnsupported
Fault Code: F1084
Message
FCoE uplink port [slotId]/[aggrPortId]/[portId] cannot be supported on springfields when FI is in eth endhost mode and FC switching modeFCoE uplink port [slotId]/[portId] cannot be supported on springfields when FI is in eth endhost mode and FC switching mode
Explanation
This fault typically occurs when a Fcoe uplink port cannot be supported on a specific FI platform.
Recommended Action
If you see this fault, take the following action:
Step 1 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: fcoe-uplink-unsupported-fi-settings
mibFaultName: fltFabricFcoeSanEpUnsupported
moClass: fabric:FcoeSanEp
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
fltFabricFcoeSanPcDown
Fault Code: F1085
Message
FCoE uplink port channel [portId] is down
Explanation
This fault typically occurs when a Fcoe uplink port channel is down.
Recommended Action
If you see this fault, take the following action:
Step 1 Check the link connectivity on the upstream switch
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFabricFcoeSanPcDown
moClass: fabric:FcoeSanPc
Affected MO: fabric/san/[id]/fcoesanpc-[portId]
fltFabricFcoeSanPcUnsupported
Fault Code: F1086
Message
FCoE uplink port channel [portId] cannot be supported on springfields when FI is in eth endhost mode and FC switching mode
Explanation
This fault typically occurs when a Fcoe uplink port cannot be supported on a specific FI platform.
Recommended Action
If you see this fault, take the following action:
Step 1 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: fcoe-uplink-port-channel-unsupported-fi-settings
mibFaultName: fltFabricFcoeSanPcUnsupported
moClass: fabric:FcoeSanPc
Affected MO: fabric/san/[id]/fcoesanpc-[portId]
fltFabricFcoeEstcEpDown
Fault Code: F1087
Message
FCoE storage port [slotId]/[aggrPortId]/[portId] is downFCoE storage port [slotId]/[portId] is down
Explanation
This fault typically occurs when a Fcoe storage port is down.
Recommended Action
If you see this fault, take the following action:
Step 1 Check the link connectivity on the upstream switch
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFabricFcoeEstcEpDown
moClass: fabric:FcoeEstcEp
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
fltFabricPinTargetDown
Fault Code: F1088
Message
Pin target is a non-existent interface
Explanation
This fault typically occurs when a PinGroup has an unresolvable target.
Recommended Action
If you see this fault, take the following action:
Step 1 Check whether the PinGroup target is correctly provisioned.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFabricPinTargetDown
moClass: fabric:PinTarget
Affected MO: fabric/lan/lan-pin-group-[name]/target-[fabricId]
Affected MO: fabric/san/san-pin-group-[name]/target-[fabricId]
fltFabricExternalEpFcZoningEnable
Fault Code: F1089
Message
FC zoning is not supported from FI when connected to an uplink FC switch. Fabric: [switchId], Port: [slotId]/[portId].
Explanation
This fault occurs when FC zoning is enabled from FI and at the same time FI is connected to an uplink FC switch.
Recommended Action
FC zones should be configured either from UCSM or from the uplink FC switch. Disable FC zoning from UCSM or disconnect the uplink switch for clearing this fault.
Fault Details
mibFaultName: fltFabricExternalEpFcZoningEnable
moClass: fabric:ExternalEp
Affected MO: fabric/eth-estc/[id]/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/eth-target-ep-[name]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/net-[name]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/phys-fc-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/net-[name]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/net-group-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/net-group-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/net-group-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/net-group-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/net-group-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/net-group-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/net-[name]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/san/net-[name]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/san/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/san/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/san/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: sys/switch-[id]/access-eth/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/eth-target-[name]
Affected MO: sys/switch-[id]/border-eth/ethestc-ep-slot-[slotId]port-[portId]/eth-target-[name]
Affected MO: sys/switch-[id]/border-eth/pc-[portId]/eth-target-[name]
Affected MO: sys/switch-[id]/border-eth/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/eth-target-[name]
Affected MO: sys/switch-[id]/border-fc/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/eth-target-[name]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/pc-[portId]/eth-target-[name]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/eth-target-[name]
Affected MO: sys/switch-[id]/phys/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/eth-target-[name]
Affected MO: sys/switch-[id]/sanmon-fc/mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/eth-target-[name]
fltFabricEthLanEpOverlapping-vlan
Fault Code: F1090
Message
On Fabric: [switchId], Port: [slotId]/[aggrPortId]/[portId] following overlapping VLANs detected: [overlappingVlans]On Fabric: [switchId], Port: [slotId]/[portId] following overlapping VLANs detected: [overlappingVlans]
Explanation
This fault occurs when Overlapping Vlans occur due to mis configuration.
Recommended Action
Ports configured on Vlans belonging to a group should not intersect with other ports of different network group belonging to Vlans which overlap.
Fault Details
Cause: configuration-error
mibFaultName: fltFabricEthLanEpOverlappingVlan
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
fltFabricEthLanPcOverlapping-vlan
Fault Code: F1091
Message
Overlapping VLANs detected on Fabric: [switchId], Port: [portId] in configured VLANs: [overlappingVlans]
Explanation
This fault occurs when Overlapping Vlans occur due to mis configuration.
Recommended Action
Ports configured on Vlans belonging to a group should not intersect with other ports of different network group belonging to Vlans which overlap.
Fault Details
Cause: configuration-error
mibFaultName: fltFabricEthLanPcOverlappingVlan
Affected MO: fabric/lan/[id]/pc-[portId]
fltFabricFcEstcEpFc-storage-port-invalid
Fault Code: F1092
Message
FC storage port should not be created in NPV mode
Explanation
This fault typically occurs when a FC Storage port is created in NPV mode
Recommended Action
FC Storage ports should not be created in NPV mode.
Fault Details
Cause: fc-storageport-npv-mode
mibFaultName: fltFabricFcEstcEpFcStoragePortInvalid
Affected MO: fabric/fc-estc/[id]/phys-fc-slot-[slotId]-port-[portId]
fltFabricFcoeEstcEpFcoe-storage-port-invalid
Fault Code: F1093
Message
FCOE storage port should not be created in NPV mode
Explanation
This fault typically occurs when a FCOE Storage port is created in NPV mode
Recommended Action
FCOE Storage ports should not be created in NPV mode.
Fault Details
Cause: fcoe-storageport-npv-mode
mibFaultName: fltFabricFcoeEstcEpFcoeStoragePortInvalid
moClass: fabric:FcoeEstcEp
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]
fltFabricFcSanPcFc-portchannel-members-invalid
Fault Code: F1094
Message
FC port channel member ports should have same max speed
Explanation
This fault typically occurs when admin speed of FC PortChannel is Auto while its member ports having different max speeds
Recommended Action
When FC PortChannel admin speed is set to Auto, member ports should have same max speed
Fault Details
Cause: fc-portchannel-members-inconsistent-speed
mibFaultName: fltFabricFcSanPcFcPortchannelMembersInvalid
Affected MO: fabric/san/[id]/pc-[portId]
fltFabricVlanMisconfigured-mcast-policy
Fault Code: F1095
Message
VLAN [name] multicast policy [mcastPolicyName] is non-default.
Explanation
This fault is raised when VLAN belonging to a Springfield fabric has a non-default multicast policy assigned to it.
Recommended Action
If you see this fault, take the following action:
Step 1 Un-assign multicast policy for the this vlan or change the multicast policy to default.
Step 2 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: vlan-mcast-policy-misconfigured
mibFaultName: fltFabricVlanMisconfiguredMcastPolicy
Affected MO: fabric/eth-estc/[id]/net-[name]
Affected MO: fabric/eth-estc/net-[name]
Affected MO: fabric/lan/[id]/net-[name]
Affected MO: fabric/lan/net-[name]
fltMgmtConnectionDisabled
Fault Code: F1097
Message
Management Connection [type] in server [id] is not operational
Explanation
This fault occurs when multiple management connections are acknowledegd.
Recommended Action
If you see this fault, take the following actions:
Step 1 Disable the management connection which is unused.
Step 2 If new management connection needs to be used, decommission and recommission server.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: another-connection-already-enabled
mibFaultName: fltMgmtConnectionDisabled
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/sas-expander-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/slot-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/fex-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/switch-[id]/mgmt/mgmt-connection-[type]
fltMgmtConnectionUnused
Fault Code: F1098
Message
Management Connection [type] in server [id] is unused
Explanation
This fault occurs when a management connection is not enabel
Recommended Action
If you see this fault, you can enable the connection if none of the management connections are enabled. Else this can be ignored
Fault Details
mibFaultName: fltMgmtConnectionUnused
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/sas-expander-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/slot-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/fex-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/switch-[id]/mgmt/mgmt-connection-[type]
fltMgmtConnectionUnsupportedConnectivity
Fault Code: F1099
Message
Unsupported connectivity for management connection [type] in server [id]
Explanation
This fault typically occurs because Cisco UCS Manager has detected that the physical connectivity of the management port of the server is unsupported.
Recommended Action
If you see this fault, take the following actions:
Step 1 Connect the management port/s of the rack mount server to the Fabric Extender/s
Step 2 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: unsupported-connectivity
mibFaultName: fltMgmtConnectionUnsupportedConnectivity
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/sas-expander-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/slot-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/fex-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/switch-[id]/mgmt/mgmt-connection-[type]
fltCallhomeEpNoSnmpPolicyForCallhome
Fault Code: F1102
Message
UCS Manager cannot apply Callhome policy if SNMP Policy is not configured or if SNMP Syscontact has an empty value. The Callhome policy from UCS Central has not been applied.
Explanation
This fault typically occurs when UCS Manager receives an invalid configuration from UCS Central wherein Callhome is configured on UCS Central but there is no SNMP Syscontact defined locally.
Recommended Action
If you see this fault, please ensure that the SNMP Policy is configured on UCSM Manager, either locally or via UCS Central.
Fault Details
Cause: callhome-config-error
mibFaultName: fltCallhomeEpNoSnmpPolicyForCallhome
fltCapabilityCatalogueLoadErrors
Fault Code: F1103
Message
Load errors: File parse errors: [fileParseFailures], provider load failures: [providerLoadFailures], XML element load errors: [loadErrors].
Explanation
The capability catalog failed to load fully. This may be caused by either a faulty UCSM image or a faulty catalog image.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the version of the capability catalog.
Step 2 Contact Cisco TAC to see if there are known issues with the catalog and if there is a catalog image that will fix the known issues.
Fault Details
Cause: load-catalog-failed
mibFaultName: fltCapabilityCatalogueLoadErrors
moClass: capability:Catalogue
Affected MO: capabilities
fltExtmgmtArpTargetsArpTargetsNotValid
Fault Code: F1114
Message
Invalid ARP Targets configured for Management Interface Polling. Error: [configStatusMessage]
Explanation
This fault typically occurs because Cisco UCS Manager has detected an invalid ArpTargets Configuration.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that Arp target ip address and external management ip address are in the same subnet.
Step 2 Verify that Arp target ip address is not the same as ip address of this system’s fabric-interconnects.
Step 3 Verify that Arp target ip address is not the same as virtual IP Address.
Fault Details
Cause: arp-targets-config-error
mibFaultName: fltExtmgmtArpTargetsArpTargetsNotValid
moClass: extmgmt:ArpTargets
Affected MO: sys/extmgmt-intf-monitor-policy/arp-target-policy
fltVnicFcPinningMisconfig
Fault Code: F1209
Message
Hard pinning target for vHBA [name], service profile [name] is missing or misconfigured
Explanation
This fault occurs when one or more vNIC target uplink ports or port channels for a hard-pinned SAN pin group are either missing or misconfigured as the wrong port type.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the SAN pin group configuration.
Step 2 Correct the configuration of the port and port channels in the pin group.
Step 3 Ensure that all required vSANs are allowed on the target ports or port channels.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltVnicFcPinningMisconfig
Affected MO: org-[name]/ls-[name]/fc-[name]
Affected MO: org-[name]/san-conn-pol-[name]/fc-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/fc-[name]
fltExtpolClientGracePeriodWarning
Fault Code: F1211
Message
UCS domain [name] registered with UCS Central has entered into the grace period.
Explanation
A UCS domain is registered with UCS Central without having a license. This fault typically occurs if this UCS domain is registered with UCS Central after all default (and procured) licenses are assigned to other UCS domains.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the number of licenses installed and consumed on UCS Central. In the Cisco UCS Central GUI, you can access the licensing information from the Operations Management tab for the UCS Central. In the Cisco UCS Central CLI, you can access the licensing information by entering the show usage detail command under license scope from service-reg session.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: license-graceperiod-entered
mibFaultName: fltExtpolClientGracePeriodWarning
Affected MO: extpol/reg/clients/client-[id]
fltExtpolClientGracePeriodWarning2
Fault Code: F1212
Message
UCS Domain [name] registered with UCS Central is running in the grace period for more than 10 days
Explanation
This UCS domain is registered with UCS Central without having a license. This fault typically occurs if this UCS domain is registered with UCS Central after all default (and procured) licenses are assigned to other UCS domains.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the number of licenses installed and consumed on UCS Central. In the Cisco UCS Central GUI, you can access the licensing information from the Operations Management tab for the UCS Central. In the Cisco UCS Central CLI, you can access the licensing information by entering the show usage detail command under the license scope.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: license-graceperiod-10days
mibFaultName: fltExtpolClientGracePeriodWarning2
Affected MO: extpol/reg/clients/client-[id]
fltExtpolClientGracePeriodWarning3
Fault Code: F1213
Message
UCS Domain [name] registered with UCS Central is running in the grace period for more than 30 days
Explanation
This UCS Domain registered with UCS Central has been running in the grace period for more than 30 days. This fault typically occurs if this UCS domain is registered with UCS Central after all default (and procured) licenses are assigned to other UCS domains and the unlicensed UCS Domains have been running for more than 120 days.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the number of licenses installed and consumed on UCS Central. In the Cisco UCS Manager GUI, you can access the licensing information from the Operations Management tab for the UCS Central. In the Cisco UCS Central CLI, you can access the licensing information by entering the show usage detail command under the license scope.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: license-graceperiod-30days
mibFaultName: fltExtpolClientGracePeriodWarning3
Affected MO: extpol/reg/clients/client-[id]
fltExtpolClientGracePeriodWarning4
Fault Code: F1214
Message
UCS Domain [name] registered with UCS Central is running in the grace period for more than 60 days
Explanation
This UCS Domain registered with UCS Central has been running in the grace period for more than 60 days. This fault typically occurs if this UCS domain is registered with UCS Central after all default (and procured) licenses are assigned to other UCS domains and the unlicensed UCS Domains have been running for more than 60 days.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the number of licenses installed and consumed on UCS Central. In the Cisco UCS Central GUI, you can access the licensing information from the Operations Management tab for the UCS Central. In the Cisco UCS Central CLI, you can access the licensing information by entering the show usage detail command under the license scope.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: license-graceperiod-60days
mibFaultName: fltExtpolClientGracePeriodWarning4
Affected MO: extpol/reg/clients/client-[id]
fltExtpolClientGracePeriodWarning5
Fault Code: F1215
Message
UCS Domain [name] registered with UCS Central is running in the grace period for more than 90 days
Explanation
This UCS Domain registered with UCS Central has been running in the grace period for more than 90 days. This fault typically occurs if this UCS domains is registered with UCS Central after all default (and procured) licenses are assigned to other UCS domains and the unlicensed UCS Domains have been running for more than 90 days.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the number of licenses installed and consumed by UCS Central. In the Cisco UCS Central GUI, you can access the licensing information from the Operations Management tab for the UCS Central. In the Cisco UCS Central CLI, you can access the licensing information by entering the show usage detail command under the license scope.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: license-graceperiod-90days
mibFaultName: fltExtpolClientGracePeriodWarning5
Affected MO: extpol/reg/clients/client-[id]
fltExtpolClientGracePeriodWarning6
Fault Code: F1216
Message
UCS Domain [name] registered with UCS Central is running in the grace period for more than 119 days
Explanation
This UCS Domain registered with UCS Central has been running in the grace period for more than 119 days. This fault typically occurs if this UCS domain is registered with UCS Central after all default (and procured) licenses are assigned to other UCS domains and the unlicensed UCS Domains have been running for more than 119 days.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the number of licenses installed and consumed on UCS Central. In the Cisco UCS Central GUI, you can access the licensing information from the Operations Management tab for UCS Central. In the Cisco UCS Central CLI, you can access the licensing information by entering the show usage detail command under the license scope.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: license-graceperiod-119days
mibFaultName: fltExtpolClientGracePeriodWarning6
Affected MO: extpol/reg/clients/client-[id]
fltExtpolClientGracePeriodWarning7
Fault Code: F1217
Message
Grace period for UCS Domain [name] registered with UCS Central has expired. Please acquire a license for the same.
Explanation
This UCS Domain registered with UCS Central has been running in the grace period for more than 120 days. UCS domains are registered with UCS Central after all default (and procured) licenses are assigned to other UCS domains and the unlicensed UCS Domains have been running for more than 120 days. At this stage, the system licensing state is set to expired.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the number of licenses installed and consumed on UCS Central. In the Cisco UCS Central GUI, you can access the licensing information from the Operations Management tab for UCS Central. In the Cisco UCS Central CLI, you can access the licensing information by entering the show usage detail command under the license scope.
Step 2 Disable the unlicensed UCS Domains to bring the number of enabled Domains down to the number of total licenses.
Step 3 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC immediately to procure more licenses.
Fault Details
Cause: license-graceperiod-expired
mibFaultName: fltExtpolClientGracePeriodWarning7
Affected MO: extpol/reg/clients/client-[id]
fltExtpolClientGracePeriodWarning1
Fault Code: F1218
Message
UCS Domain [name] is registered with UCS Central without a valid license.
Explanation
This UCS domain is registered with UCS Central without having a license. This fault typically occurs if this UCS domain is registered with UCS Central without the initial activation license and after all default licenses are assigned to other UCS domains.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check if the initial activation license is installed on UCS Central. In the Cisco UCS Central GUI, you can access the licensing information from the Operations Management tab for UCS Central. In the Cisco UCS Central CLI, you can access the licensing information by entering the show usage detail command under the license scope.
Step 2 Disable the unlicensed UCS Domains to bring the number of enabled Domains down to the number of total licenses.
Step 3 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC immediately to procure more licenses.
Fault Details
Cause: license-insufficient
mibFaultName: fltExtpolClientGracePeriodWarning1
Affected MO: extpol/reg/clients/client-[id]
fltStorageItemFilesystemIssues
Fault Code: F1219
Message
Partition [name] on fabric interconnect [id] has file system errors
Explanation
This fault occurs when the partition develops faults
Recommended Action
If you see this fault, take the following actions:
Step 1 Create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-degraded
mibFaultName: fltStorageItemFilesystemIssues
Affected MO: sys/switch-[id]/stor-part-[name]
fltStorageInitiatorDuplicate-fc-zone
Fault Code: F1220
Message
Duplicate FC zones are created for initiator [name], because the same target wwpn [duplicateTarget] is duplicately configured in both boot and storage connection policy.
Explanation
Duplicate FC zones are created, because the same target wwpn is duplicately configured in both boot and storage connection policy.
Recommended Action
If you see this fault, take the following action:
Step 1 Remove the duplicate target wwpn from either boot policy or storage connection policy.
Fault Details
Cause: configuration-error
mibFaultName: fltStorageInitiatorDuplicateFcZone
moClass: storage:Initiator
Affected MO: org-[name]/ls-[name]/grp-[name]/ini-[name]
Affected MO: org-[name]/san-conn-pol-[name]/grp-[name]/ini-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/grp-[name]/ini-[name]
fltStorageIniGroupSwitch-mode-disabled
Fault Code: F1221
Message
FC zones cannot be deployed because FI is not running in FC switch mode.
Explanation
FC zones cannot be deployed because FI is not running in FC switch mode.
Recommended Action
If you see this fault, take the following action:
Step 1 If you want FC zones to be deployed, enable FC switch mode.
Step 2 If FI is running FC end-host mode and you want this fault to be cleared, remove initiators from the initiator group.
Fault Details
Cause: configuration-error
mibFaultName: fltStorageIniGroupSwitchModeDisabled
moClass: storage:IniGroup
Affected MO: org-[name]/ls-[name]/grp-[name]
Affected MO: org-[name]/san-conn-pol-[name]/grp-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/grp-[name]
fltPkiKeyRingModulus
Fault Code: F1222
Message
[name] Keyring’s key modulus is invalid.
Explanation
This fault occurs when keyring is created without modulus set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
Cause: invalid-keyring-modulus
mibFaultName: fltPkiKeyRingModulus
Affected MO: sys/pki-ext/keyring-[name]
fltAaaOrgLocaleOrgNotPresent
Fault Code: F1223
Message
Locale Org [name] can’t be deployed. Error: [configStatusMessage]
Explanation
This fault typically occurs because Cisco UCS Manager has detected an unidentified org reference.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the org dn referenced in this Org is exists, if not create the same.
Fault Details
Cause: locale-org-config-error
mibFaultName: fltAaaOrgLocaleOrgNotPresent
Affected MO: sys/user-ext/locale-[name]/org-[name]
fltNetworkOperLevelExtraprimaryvlans
Fault Code: F1229
Message
Fabric Interconnect [id]: Number of primary vlans exceeds the max limit on the FI: Number of Primary Vlans: [primaryVlanCount] and Max primary vlans allowed: [maxPrimaryVlanCount]
Explanation
This fault occurs when the fabric interconnect has more number of primary vlans than what is supported.
Recommended Action
If you see this fault, take the following actions:
Step 1 It is recommended that operator should delete the extra primary vlans than are there in the FI. System may appear to be normally functioning even with these extra primary vlans in place. However there may be performance issues observed as the system is operating above the recommended scale limits..
Step 2 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: extra-primary-vlans
mibFaultName: fltNetworkOperLevelExtraprimaryvlans
moClass: network:OperLevel
Affected MO: sys/switch-[id]/oper-level
fltEquipmentHealthLedCriticalError
Fault Code: F1236
Message
[dn] shows error. Reason [healthLedStateQualifier]
Explanation
This fault is raised Blade LED changes to amber blinking
Recommended Action
If you see this fault, take the following actions:
Step 1 Read fault summary and determine course of action.
Fault Details
Cause: health-led-amber-blinking
mibFaultName: fltEquipmentHealthLedCriticalError
moClass: equipment:HealthLed
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/health-led
Affected MO: sys/chassis-[id]/blade-[slotId]/health-led
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/health-led
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/health-led
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/health-led
Affected MO: sys/chassis-[id]/health-led
Affected MO: sys/chassis-[id]/psu-[id]/health-led
Affected MO: sys/chassis-[id]/slot-[id]/health-led
Affected MO: sys/fex-[id]/health-led
Affected MO: sys/fex-[id]/psu-[id]/health-led
Affected MO: sys/fex-[id]/slot-[id]/health-led
Affected MO: sys/rack-unit-[id]/ext-board-[id]/health-led
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/health-led
Affected MO: sys/rack-unit-[id]/health-led
Affected MO: sys/rack-unit-[id]/psu-[id]/health-led
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/health-led
Affected MO: sys/switch-[id]/psu-[id]/health-led
fltEquipmentHealthLedMinorError
Fault Code: F1237
Message
[dn] shows error. Reason: [healthLedStateQualifier]
Explanation
This fault is raised Blade LED changes to amber
Recommended Action
If you see this fault, take the following actions:
Step 1 Read fault summary and determine course of action.
Fault Details
mibFaultName: fltEquipmentHealthLedMinorError
moClass: equipment:HealthLed
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/health-led
Affected MO: sys/chassis-[id]/blade-[slotId]/health-led
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/health-led
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/health-led
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/health-led
Affected MO: sys/chassis-[id]/health-led
Affected MO: sys/chassis-[id]/psu-[id]/health-led
Affected MO: sys/chassis-[id]/slot-[id]/health-led
Affected MO: sys/fex-[id]/health-led
Affected MO: sys/fex-[id]/psu-[id]/health-led
Affected MO: sys/fex-[id]/slot-[id]/health-led
Affected MO: sys/rack-unit-[id]/ext-board-[id]/health-led
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/health-led
Affected MO: sys/rack-unit-[id]/health-led
Affected MO: sys/rack-unit-[id]/psu-[id]/health-led
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/health-led
Affected MO: sys/switch-[id]/psu-[id]/health-led
fltVnicEtherIfRemoteVlanUnresolvable
Fault Code: F1249
Message
The named vlan [name] for vNIC [name] cannot be resolved remotely
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
Cause: referenced-remote-vlan-unresolvable
mibFaultName: fltVnicEtherIfRemoteVlanUnresolvable
Affected MO: fabric/lan/network-sets/fabric-network-[name]/fabric-network-def-[name]/vm-network-def-[name]/if-[name]
Affected MO: fabric/lan/profiles/vnic-[name]/if-[name]
Affected MO: fabric/lanmon/eth-flow-monitoring/flow-exporter-profile-[name]/if-[name]
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/lan-conn-templ-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/ipc-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ipc-[name]/if-[name]
fltVnicFcIfRemoteVsanUnresolvable
Fault Code: F1250
Message
The named vsan [name] for vHBA [name] cannot be resolved remotely
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
Cause: referenced-remote-vsan-unresolvable
mibFaultName: fltVnicFcIfRemoteVsanUnresolvable
Affected MO: org-[name]/ls-[name]/fc-[name]/if-default
Affected MO: org-[name]/san-conn-pol-[name]/fc-[name]/if-default
Affected MO: org-[name]/san-conn-templ-[name]/if-default
Affected MO: org-[name]/tier-[name]/ls-[name]/fc-[name]/if-default
fltVnicEtherVirtualization-conflict
Fault Code: F1251
Message
Multiple connection policies cannot be assigned to the same Eth vNIC
Explanation
This fault occurs when multiple connection policies are assigned to the same vNIC.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check on the vNIC if different types of connection policies (dynamic/VMQ) are assigned. Keep only one type.
Step 2 Check on the vNIC through CLI if more than one connection policy of the same type is assigned. Keep only one connection policy.
Fault Details
Cause: multiple-connection-policies
mibFaultName: fltVnicEtherVirtualizationConflict
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]
fltLsIssuesIscsi-config-failed
Fault Code: F1252
Message
Service Profile [name] configuration failed due to iSCSI issue [iscsiConfigIssues]
Explanation
This fault typically occurs when Cisco UCS Manager Service Profile configuration failed due to iSCSI Config Issues.
Recommended Action
If you see this fault, take the following actions:
Step 1 Correct the Service Profile iSCSI Configuration as per the issue reported.
Step 2 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: configuration-failed
mibFaultName: fltLsIssuesIscsiConfigFailed
Affected MO: org-[name]/ls-[name]/config-issue
Affected MO: org-[name]/tier-[name]/ls-[name]/config-issue
fltStorageLocalDiskMissing
Fault Code: F1256
Message
Local disk [id] missing on server [chassisId]/[slotId]Local disk [id] missing on server [id]Local disk [id] missing on storage enclosure [id]Local disk [id] missing on chassis [id]
Explanation
This fault occurs when a disk is missing.
Recommended Action
If you see this fault, take the following action:
Step 1 Insert the disk.
Fault Details
mibFaultName: fltStorageLocalDiskMissing
moClass: storage:LocalDisk
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]
fltStorageFlexFlashControllerInoperable
Fault Code: F1257
Message
FlexFlash Controller [id] on server [chassisId]/[slotId] is inoperable. Reason: [operQualifierReason] Status: [controllerHealth]FlexFlash Controller [id] on server [id] is inoperable. Reason: [operQualifierReason] Status: [controllerHealth]
Explanation
This fault occurs when the flexflash controller is inaccessible.
Recommended Action
If you see this fault, take the following action:
Step 1 If reported as Firmware Mismatch, update the CIMC and Board Controller firmware
Step 2 If reported as Fatal Error, reset the CIMC and update Board Controller firmware
Step 3 For PCI and mezz-based controllers, check the seating of the storage controller. If the problem persists, replace the controller
Fault Details
Cause: equipment-inoperable
mibFaultName: fltStorageFlexFlashControllerInoperable
moClass: storage:FlexFlashController
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-flexflash-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-flexflash-[id]
Affected MO: sys/rack-unit-[id]/board/storage-flexflash-[id]
fltStorageFlexFlashCardInoperable
Fault Code: F1258
Message
FlexFlash Card [slotNumber] on server [chassisId]/[slotId] is inoperable. Reason: [operQualifierReason]FlexFlash Card [slotNumber] on server [id] is inoperable. Reason: [operQualifierReason]
Explanation
This fault occurs when the flexflash card is inaccessible.
Recommended Action
If you see this fault, take the following action:
Step 1 If reported as Write Protected, then remove write protection from the card
Step 2 If reported as Invalid Capacity, use an OS disk utility to delete/recreate the partitions
Step 3 If the above action did not resolve the issue, replace the card
Fault Details
Cause: equipment-inoperable
mibFaultName: fltStorageFlexFlashCardInoperable
moClass: storage:FlexFlashCard
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-flexflash-[id]/card-[slotNumber]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-flexflash-[id]/card-[slotNumber]
Affected MO: sys/rack-unit-[id]/board/storage-flexflash-[id]/card-[slotNumber]
fltStorageFlexFlashCardMissing
Fault Code: F1259
Message
FlexFlash Card [slotNumber] missing on server [chassisId]/[slotId]FlexFlash Card [slotNumber] missing on server [id]
Explanation
This fault occurs when a FlexFlash Card is missing.
Recommended Action
If you see this fault, take the following action:
Step 1 Insert the Card.
Fault Details
mibFaultName: fltStorageFlexFlashCardMissing
moClass: storage:FlexFlashCard
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-flexflash-[id]/card-[slotNumber]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-flexflash-[id]/card-[slotNumber]
Affected MO: sys/rack-unit-[id]/board/storage-flexflash-[id]/card-[slotNumber]
fltStorageFlexFlashVirtualDriveDegraded
Fault Code: F1260
Message
FlexFlash Virtual Drive RAID degraded on server [chassisId]/[slotId]. Reason: [raidState]FlexFlash Virtual Drive RAID degraded on server [id]. Reason: [raidState]
Explanation
This fault occurs when the flexflash raid is degraded.
Recommended Action
If you see this fault, take the following action:
Step 1 Re-acknowledge the server by setting the flexflash scrub policy to yes. Please note that this action will erase all data in the card(s)
Step 2 Verify the health of the controller/card(s). If the above action did not resolve the issue, replace the card(s)
Fault Details
Cause: equipment-degraded
mibFaultName: fltStorageFlexFlashVirtualDriveDegraded
moClass: storage:FlexFlashVirtualDrive
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-flexflash-[id]/vd-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-flexflash-[id]/vd-[id]
Affected MO: sys/rack-unit-[id]/board/storage-flexflash-[id]/vd-[id]
fltStorageFlexFlashVirtualDriveInoperable
Fault Code: F1261
Message
FlexFlash Virtual Drive on server [chassisId]/[slotId] is inoperable. Reason: [raidState]FlexFlash Virtual Drive on server [id] is inoperable. Reason: [raidState]
Explanation
This fault occurs when the flexflash virtual drive is inoperable.
Recommended Action
If you see this fault, take the following action:
Step 1 Re-acknowledge the server by setting the flexflash scrub policy to yes. Please note that this action will erase all data in the card(s)
Step 2 Verify the health of the controller/card(s). If the above action did not resolve the issue, replace the card(s)
Fault Details
Cause: equipment-inoperable
mibFaultName: fltStorageFlexFlashVirtualDriveInoperable
moClass: storage:FlexFlashVirtualDrive
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-flexflash-[id]/vd-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-flexflash-[id]/vd-[id]
Affected MO: sys/rack-unit-[id]/board/storage-flexflash-[id]/vd-[id]
fltStorageFlexFlashControllerUnhealthy
Fault Code: F1262
Message
FlexFlash Controller [id] on server [chassisId]/[slotId] is unhealthy. Reason: [operQualifierReason] Status: [controllerHealth]FlexFlash Controller [id] on server [id] is unhealthy. Reason: [operQualifierReason] Status: [controllerHealth]
Explanation
This fault occurs when the flexflash controller is unhealthy.
Recommended Action
If you see this fault, take the following action:
Step 1 If reported as Old Firmware/Firmware Mismatch, update the CIMC and Board Controller firmware, reboot the server
Step 2 Re-acknowledge the server by setting the flexflash scrub policy to yes. Please note that this action will erase all data in the card(s)
Step 3 Verify the health of the controller. If the above action did not resolve the issue, replace the card(s)
Fault Details
Cause: equipment-unhealthy
mibFaultName: fltStorageFlexFlashControllerUnhealthy
moClass: storage:FlexFlashController
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-flexflash-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-flexflash-[id]
Affected MO: sys/rack-unit-[id]/board/storage-flexflash-[id]
fltAaaProviderGroupProvidergroupsize
Fault Code: F1279
Message
For [dn]: Server Group [name] has [size] provider references. Authentication might fail, if this provider group is used with auth-domain.
Explanation
This fault typically occurs because Cisco UCS Manager has detected provider-group with 0 provider references..
Recommended Action
If you see this fault, take the following actions:
Step 1 Need to delete the provider group which does not have any provider references.
Step 2 Or Add provider references to provider group.
Fault Details
Cause: provider-group-size-empty
mibFaultName: fltAaaProviderGroupProvidergroupsize
moClass: aaa:ProviderGroup
Affected MO: sys/ldap-ext/providergroup-[name]
Affected MO: sys/radius-ext/providergroup-[name]
Affected MO: sys/tacacs-ext/providergroup-[name]
fltFirmwareAutoSyncPolicyDefaultHostPackageMissing
Fault Code: F1284
Message
Default host firmware package is missing or deleted.
Explanation
This fault typically occurs for the following reasons: when Auto Firmware Sync Policy is set Auto-acknowledge or User-acknowledge and default host firmware pack is not available.
- Auto Firmware Sync is not happening.
- Default host firmware package is missing or deleted.
Recommended Action
If you see this fault, take the following actions:
Step 1 Go to Servers tab and expand policies node. Select Host Firmware Packages under policies node.
Step 2 If the FSM failed, review the error message in the FSM.
Step 3 Create a host firmware package with name ’default’. If the problem persists, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: default-hostpack-missing
mibFaultName: fltFirmwareAutoSyncPolicyDefaultHostPackageMissing
moClass: firmware:AutoSyncPolicy
Affected MO: org-[name]/fw-auto-sync
fltFirmwareAutoSyncPolicyDefaultHostPackageMissingVersions
Fault Code: F1285
Message
B-series,C-series and M-series package versions are empty in default host firmware package
Explanation
This fault typically occurs for the following reasons: when Auto Firmware Sync Policy is set Auto-acknowledge or User-acknowledge and default host firmware pack is not having any server versions set.
- Auto Firmware Sync is not happening.
- Default host firmware package has blade or rack versions empty.
Recommended Action
If you see this fault, take the following actions:
Step 1 Go to Servers tab and expand policies node. Select Host Firmware Packages under policies node.
Step 2 If the FSM failed, review the error message in the FSM.
Step 3 Open the ’default’ host firmware package and update the rack and/or blade version. If the problem persists, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: default-hostpack-missing-versions
mibFaultName: fltFirmwareAutoSyncPolicyDefaultHostPackageMissingVersions
moClass: firmware:AutoSyncPolicy
Affected MO: org-[name]/fw-auto-sync
fltFabricNetflowMonSessionFlowMonConfigFail
Fault Code: F1304
Message
Configuration for traffic flow monitor [name] failed, reason: [configFailReason]
Explanation
This fault typically occurs when the configuration of a traffic flow monitoring session is incorrect.
Recommended Action
If you see this fault, correct the configuration problem provided in the fault description.
Fault Details
mibFaultName: fltFabricNetflowMonSessionFlowMonConfigFail
moClass: fabric:NetflowMonSession
Affected MO: fabric/lanmon/eth-flow-monitoring/netflow-mon-[name]
fltFabricNetflowMonSessionNetflowSessionConfigFail
Fault Code: F1305
Message
Netflow session configuration failed because [configQualifier]
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltFabricNetflowMonSessionNetflowSessionConfigFail
moClass: fabric:NetflowMonSession
Affected MO: fabric/lanmon/eth-flow-monitoring/netflow-mon-[name]
fltFabricPooledVlanNamedVlanUnresolved
Fault Code: F1306
Message
VLAN [name] for VLAN group [name] cannot be resolved to any existing vlans.
Explanation
This fault typically occurs when a named VLAN in VLAN group cannot be resolved to any existing vlans.
Recommended Action
If you see this fault, take the following action:
Step 1 Create VLAN.
Step 2 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: named-vlan-unresolved
mibFaultName: fltFabricPooledVlanNamedVlanUnresolved
moClass: fabric:PooledVlan
Affected MO: fabric/lan/[id]/net-group-[name]/net-[name]
Affected MO: fabric/lan/net-group-[name]/net-[name]
fltExtvmmVMNDRefVmNetworkReferenceIncorrect
Fault Code: F1320
Message
VM Network [name] references [vmNetworkDefName] that is already being referenced by another VM Network
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
Cause: vm-network-reference-incorrect
mibFaultName: fltExtvmmVMNDRefVmNetworkReferenceIncorrect
Affected MO: fabric/lan/vm-network-sets/vm-network-[name]/vm-network-def-ref[name]
fltExtmgmtNdiscTargetsNdiscTargetsNotValid
Fault Code: F1321
Message
Invalid NDISC Targets configured for Management Interface Polling. Error: [configStatusMessage]
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
Cause: ndisc-targets-config-error
mibFaultName: fltExtmgmtNdiscTargetsNdiscTargetsNotValid
moClass: extmgmt:NdiscTargets
Affected MO: sys/extmgmt-intf-monitor-policy/ndisc-target-policy
fltFirmwareBootUnitPowerCycleRequired
Fault Code: F1325
Message
Board controller upgraded, manual a/c power cycle required on server [serverId]
Explanation
None set.
Recommended Action
If you see this fault, take the following actions:
Step 1 Power cycle the board controller.
Fault Details
Cause: board-ctrl-upgraded
mibFaultName: fltFirmwareBootUnitPowerCycleRequired
moClass: firmware:BootUnit
Affected MO: capabilities/ep/mgmt-ext/fw-boot-def/bootunit-[type]
Affected MO: capabilities/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/graphics-card-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/onboard-device-[deviceType]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/onboard-device-[deviceType]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/graphics-card-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/onboard-device-[deviceType]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/onboard-device-[deviceType]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/psu-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/sas-expander-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/sas-expander-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/sas-expander-[id]/onboard-device-[deviceType]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/slot-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/onboard-device-[deviceType]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/fex-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/fex-[id]/psu-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/graphics-card-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/onboard-device-[deviceType]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/onboard-device-[deviceType]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/psu-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/switch-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/switch-[id]/psu-[id]/fw-boot-def/bootunit-[type]
fltMgmtControllerUnsupportedDimmBlacklisting
Fault Code: F1328
Message
Dimm blacklisting is not supported on server [chassisId]/[slotId]Dimm blacklisting is not supported on server [id]
Explanation
This fault typically occurs when the CIMC firmware on a server is an earlier release than Cisco UCS, Release 2.2.
Recommended Action
If you see this fault, consider upgrading the CIMC firmware, and the entire Cisco UCS instance if necessary, to Cisco UCS, Release 2.2 or later.
Fault Details
Cause: incompatible-server-firmware
mibFaultName: fltMgmtControllerUnsupportedDimmBlacklisting
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/mgmt
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/mgmt
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/mgmt
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt
Affected MO: sys/chassis-[id]/boardController/mgmt
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/mgmt
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/mgmt
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/mgmt
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/mgmt
Affected MO: sys/chassis-[id]/mgmt
Affected MO: sys/chassis-[id]/sas-expander-[id]/mgmt
Affected MO: sys/chassis-[id]/shared-io-module/mgmt
Affected MO: sys/chassis-[id]/slot-[id]/boardController/mgmt
Affected MO: sys/chassis-[id]/slot-[id]/mgmt
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/mgmt
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/mgmt
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt
Affected MO: sys/fex-[id]/mgmt
Affected MO: sys/fex-[id]/slot-[id]/mgmt
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/mgmt
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/mgmt
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt
Affected MO: sys/rack-unit-[id]/boardController/mgmt
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/mgmt
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt
Affected MO: sys/rack-unit-[id]/mgmt
Affected MO: sys/switch-[id]/mgmt
fltFabricEthLanEpUdldLinkDown
Fault Code: F1358
Message
UDLD state for ether port [slotId]/[aggrPortId]/[portId] on fabric interconnect [switchId] is: [udldOperState].UDLD state for ether port [slotId]/[portId] on fabric interconnect [switchId] is: [udldOperState].
Explanation
This fault occurs when an ethernet uplink port is unidirectional connected.
Recommended Action
If you see this fault, take the following action:
Step 1 Check the tx and rx connection of the uplink port.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFabricEthLanEpUdldLinkDown
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
fltFabricEthLanPcEpUdldLinkDown
Fault Code: F1359
Message
UDLD state for ether port [slotId]/[aggrPortId]/[portId] on fabric interconnect [switchId] is: [udldOperState].UDLD state for ether port [slotId]/[portId] on fabric interconnect [switchId] is: [udldOperState].
Explanation
This fault occurs when an ethernet uplink port-channel member is unidirectional connected.
Recommended Action
If you see this fault, take the following action:
Step 1 Check the tx and rx connection of the uplink port.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFabricEthLanPcEpUdldLinkDown
moClass: fabric:EthLanPcEp
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
fltFabricFcoeSanEpUdldLinkDown
Fault Code: F1360
Message
UDLD state for ether port [slotId]/[portId] on fabric interconnect [switchId] is: [udldOperState].UDLD state for ether port [slotId]/[portId] on fabric interconnect [switchId] is: [udldOperState].
Explanation
This fault occurs when a FCoE uplink port is unidirectional connected.
Recommended Action
If you see this fault, take the following action:
Step 1 Check the tx and rx connection of the uplink port.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFabricFcoeSanEpUdldLinkDown
moClass: fabric:FcoeSanEp
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
fltFabricFcoeSanPcEpUdldLinkDown
Fault Code: F1361
Message
UDLD state for ether port [slotId]/[aggrPortId]/[portId] on fabric interconnect [switchId] is: [udldOperState].UDLD state for ether port [slotId]/[portId] on fabric interconnect [switchId] is: [udldOperState].
Explanation
This fault occurs when a FCoE uplink port-channel member is unidirectional connected.
Recommended Action
If you see this fault, take the following action:
Step 1 Check the tx and rx connection of the uplink port.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFabricFcoeSanPcEpUdldLinkDown
moClass: fabric:FcoeSanPcEp
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
fltFirmwareStatusCimcFirmwareMismatch
Fault Code: F1365
Message
Aggregate blade CIMC firmware mismatch. Firmware: [cimcVersion]
Explanation
This fault typically occurs when the CIMC firmware image on master and slave node in an aggregate blade does not match.
Recommended Action
Update and activate master and slave CIMC to same firmware version.
Fault Details
Cause: cimc-firmware-mismatch
mibFaultName: fltFirmwareStatusCimcFirmwareMismatch
Affected MO: sys/chassis-[id]/blade-[slotId]/fw-status
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/fw-status
Affected MO: sys/chassis-[id]/fw-status
Affected MO: sys/chassis-[id]/psu-[id]/fw-status
Affected MO: sys/chassis-[id]/slot-[id]/fw-status
Affected MO: sys/fex-[id]/psu-[id]/fw-status
Affected MO: sys/fex-[id]/slot-[id]/fw-status
Affected MO: sys/fw-status
Affected MO: sys/rack-unit-[id]/fw-status
Affected MO: sys/rack-unit-[id]/psu-[id]/fw-status
Affected MO: sys/switch-[id]/fw-status
Affected MO: sys/switch-[id]/psu-[id]/fw-status
fltFirmwareStatusPldFirmwareMismatch
Fault Code: F1366
Message
Aggregate blade board controller firmware mismatch. Firmware: [pldVersion]
Explanation
This fault typically occurs when the board controller firmware image on master and slave node in an aggregate blade does not match.
Recommended Action
Update master and slave board controller to same firmware version.
Fault Details
Cause: pld-firmware-mismatch
mibFaultName: fltFirmwareStatusPldFirmwareMismatch
Affected MO: sys/chassis-[id]/blade-[slotId]/fw-status
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/fw-status
Affected MO: sys/chassis-[id]/fw-status
Affected MO: sys/chassis-[id]/psu-[id]/fw-status
Affected MO: sys/chassis-[id]/slot-[id]/fw-status
Affected MO: sys/fex-[id]/psu-[id]/fw-status
Affected MO: sys/fex-[id]/slot-[id]/fw-status
Affected MO: sys/fw-status
Affected MO: sys/rack-unit-[id]/fw-status
Affected MO: sys/rack-unit-[id]/psu-[id]/fw-status
Affected MO: sys/switch-[id]/fw-status
Affected MO: sys/switch-[id]/psu-[id]/fw-status
fltSysdebugLogExportStatusLogExportFailure
Fault Code: F1369
Message
Log export to remote server failed from [switchId]:[exportFailureReason]
Explanation
This fault occurs when Cisco UCS Manager cannot transfer a log file to a remote server. This is typically the result of one of the following issues:
- The remote server is not accessible.
- One or more of the parameters for the remote server that are specified for the log export target, such as path, username, password, ssh-key and server name, are incorrect.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify the connectivity to the remote server.
Step 2 Verify the path information of the remote server.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltSysdebugLogExportStatusLogExportFailure
moClass: sysdebug:LogExportStatus
Affected MO: sys/sysdebug/log-export-policy/log-export-status-[switchId]
fltVnicEtherVirtualization-netflow-conflict
Fault Code: F1380
Message
Netflow and VMQ/SRIOV-USNIC policies cannot be assigned to the same Eth vNIC
Explanation
This fault typically occurs when a netflow src vnic is made a USNIC or VMQ vnic
Recommended Action
If you see this fault, take the following actions:
Step 1 Remove the vnic from a netflow session or remove the usnic/vmq policy
Step 2 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: multiple-connection-policies
mibFaultName: fltVnicEtherVirtualizationNetflowConflict
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]
fltFabricVlanPrimaryVlanMissingForIsolated
Fault Code: F1382
Message
Primary Vlan can not be resolved for isolated vlan [name]
Explanation
This fault typically occurs when Cisco UCS Manager encounters a problem resolving the primary VLAN ID corresponding to a particular isolated VLAN.
Recommended Action
If you see this fault, take the following actions:
Step 1 Associate the isolated VLAN with a valid primary VLAN.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: primary-vlan-missing-for-isolated
mibFaultName: fltFabricVlanPrimaryVlanMissingForIsolated
Affected MO: fabric/eth-estc/[id]/net-[name]
Affected MO: fabric/eth-estc/net-[name]
Affected MO: fabric/lan/[id]/net-[name]
Affected MO: fabric/lan/net-[name]
fltFabricVlanPrimaryVlanMissingForCommunity
Fault Code: F1383
Message
Primary Vlan can not be resolved for community vlan [name]
Explanation
This fault typically occurs when Cisco UCS Manager encounters a problem resolving the primary VLAN ID corresponding to a particular community VLAN.
Recommended Action
If you see this fault, take the following actions:
Step 1 Associate the community VLAN with a valid primary VLAN.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: primary-vlan-missing-for-community
mibFaultName: fltFabricVlanPrimaryVlanMissingForCommunity
Affected MO: fabric/eth-estc/[id]/net-[name]
Affected MO: fabric/eth-estc/net-[name]
Affected MO: fabric/lan/[id]/net-[name]
Affected MO: fabric/lan/net-[name]
fltFabricVlanMismatch-a
Fault Code: F1384
Message
VLAN [name] has [overlapStateForA] with another vlan under lan-cloud/appliance-cloud for the fabric interconnect A
Explanation
This fault typically occurs when private vlan properties of VLAN under one cloud conflicts with the private vlan properties of VLAN under another cloud for the fabric interconnect A. The cloud here means either a LAN cloud or an appliance cloud. This issue can stop the usage of this vlan.
Recommended Action
If you see this fault, take the following action:
Step 1 Check the sharing property of the VLAN under both clouds and fabric A referred by its VLAN ID.
Step 2 If the sharing property of the VLAN does not match with the VLAN on the other cloud, then change the sharing property of either of the VLANs, so that it matches with each other.
Step 3 If the VLAN is a isolated/community vlan, check the pubnwname property of the VLAN under both clouds referred by its VLAN ID.
Step 4 If the pubnwname property of the isolated/community VLAN does not match with the isolated/community VLAN on the other cloud, then change the pubnwname property of either of the VLANs, so that it matches with each other.
Step 5 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFabricVlanMismatchA
Affected MO: fabric/eth-estc/[id]/net-[name]
Affected MO: fabric/eth-estc/net-[name]
Affected MO: fabric/lan/[id]/net-[name]
Affected MO: fabric/lan/net-[name]
fltFabricVlanMismatch-b
Fault Code: F1385
Message
VLAN [name] has [overlapStateForB] with another vlan under lan-cloud/appliance-cloud for the fabric interconnect B
Explanation
This fault typically occurs when private vlan properties of VLAN under one cloud conflicts with the private vlan properties of VLAN under another cloud for the fabric interconnect B. The cloud here means either a LAN cloud or an appliance cloud. This issue can stop the usage of this vlan.
Recommended Action
If you see this fault, take the following action:
Step 1 Check the sharing property of the VLAN under both clouds and fabric B referred by its VLAN ID.
Step 2 If the sharing property of the VLAN does not match with the VLAN on the other cloud, then change the sharing property of either of the VLANs, so that it matches with each other.
Step 3 If the VLAN is a isolated/community vlan, check the pubnwname property of the VLAN under both clouds referred by its VLAN ID.
Step 4 If the pubnwname property of the isolated/community VLAN does not match with the isolated/community VLAN on the other cloud, then change the pubnwname property of either of the VLANs, so that it matches with each other.
Step 5 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFabricVlanMismatchB
Affected MO: fabric/eth-estc/[id]/net-[name]
Affected MO: fabric/eth-estc/net-[name]
Affected MO: fabric/lan/[id]/net-[name]
Affected MO: fabric/lan/net-[name]
fltFabricVlanErrorAssocPrimary
Fault Code: F1386
Message
VLAN [name] is in error state because the associated primary vlan [assocPrimaryVlanState]
Explanation
This fault typically occurs when there is an error in associated primary vlan of a secondary VLAN. This issue can stop the usage of this vlan.
Recommended Action
If you see this fault, take the following action:
Step 1 Check the pubnwname property of the VLAN.
Step 2 If the pubnwname is not given or refers to a non-existing primary vlan, give a name of a primary vlan which is in good state.
Step 3 If the pubnwname refers to a vlan which is not a primary vlan, then either change the referred vlan to be a primary vlan or give a different primary vlan.
Step 4 If the pubnwname refers to a valid primary vlan, then check the state of the primary VLAN.
Step 5 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: vlan-error-assoc-primary
mibFaultName: fltFabricVlanErrorAssocPrimary
Affected MO: fabric/eth-estc/[id]/net-[name]
Affected MO: fabric/eth-estc/net-[name]
Affected MO: fabric/lan/[id]/net-[name]
Affected MO: fabric/lan/net-[name]
fltLsServerSvnicNotPresent
Fault Code: F1388
Message
Service profile [name] does not contain service vnics for netflow.
Explanation
The service profile does not have service vnics, hence netflow will not function on this server. This fault typically occurs as a result of one of the following issues:
- Service profile has maximum number of vnics already created, hence cannot accomodate service vnics required for netflow.
Recommended Action
If you see this fault, take the following actions:
Step 1 If you have already enabled netflow, please reduce the number of vnics on the SP to accomodate service vnics.
Step 2 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltLsServerSvnicNotPresent
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]
fltLsIssuesKvmPolicyUnsupported
Fault Code: F1389
Message
Kvm mgmt policy not supported by current CIMC version
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
Cause: unsupported-cimc-firmware
mibFaultName: fltLsIssuesKvmPolicyUnsupported
Affected MO: org-[name]/ls-[name]/config-issue
Affected MO: org-[name]/tier-[name]/ls-[name]/config-issue
fltMgmtBackupPolicyConfigConfiguration backup outdated
Fault Code: F1392
Message
Config backup may be outdated
Explanation
This fault occurs when last backup configuration is taken long back
Recommended Action
If you see this fault, take the following actions:
Step 1 Please take a configuration backup
Fault Details
Cause: config-backup-outdated
mibFaultName: fltMgmtBackupPolicyConfigConfigurationBackupOutdated
moClass: mgmt:BackupPolicyConfig
Affected MO: sys/bkup-policy-cfg
fltNetworkOperLevelExtrasecondaryvlans
Fault Code: F1396
Message
Fabric Interconnect [id]: Number of secondary vlans exceeds the max limit on the FI: Number of secondary vlans: [secondaryVlanCount] and Max secondary vlans allowed: [maxSecondaryVlanCount]
Explanation
This fault occurs when the fabric interconnect has more number of secondary vlans than what is supported.
Recommended Action
If you see this fault, take the following actions:
Step 1 It is recommended that operator should delete the extra secondary vlans that are there in the FI. System may appear to be normally functioning even with these extra secondary vlans in place. However there may be performance issues observed as the system is operating above the recommended scale limits..
Step 2 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: extra-secondary-vlans
mibFaultName: fltNetworkOperLevelExtrasecondaryvlans
moClass: network:OperLevel
Affected MO: sys/switch-[id]/oper-level
fltSwVlanExtrasecondaryvlansperprimary
Fault Code: F1397
Message
Number of secondary vlans associated with the primary vlan [id] in Fabric Interconnect [switchId] exceeds the max limit: Number of secondary vlans: [secVlanPerPrimaryVlanCount].
Explanation
This fault occurs when the fabric interconnect has more number of secondary vlans per primary vlan than what is supported.
Recommended Action
If you see this fault, take the following actions:
Step 1 It is recommended that operator should delete the extra secondary vlans on this primary vlan that are there in the FI. System may appear to be normally functioning even with these extra secondary vlans on this primary vlan in place. However there may be performance issues observed as the system is operating above the recommended scale limits..
Step 2 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: extra-secondary-vlans-per-primary
mibFaultName: fltSwVlanExtrasecondaryvlansperprimary
Affected MO: fabric/lan/profiles/vnic-[name]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/sas-expander-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/sas-expander-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/slot-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/slot-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/vnic-[name]/vlan-[id]
Affected MO: sys/fex-[id]/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/fex-[id]/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/fex-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/fex-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/switch-[id]/access-eth/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/access-eth/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/access-eth/slot-[slotId]-aggr-port-[aggrPortId]/fcoeestc-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/access-eth/slot-[slotId]-aggr-port-[aggrPortId]/fcoesan-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-eth/ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-eth/ethestc-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-eth/pc-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-eth/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-eth/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-eth/slot-[slotId]-aggr-port-[aggrPortId]/fcoeestc-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-eth/slot-[slotId]-aggr-port-[aggrPortId]/fcoesan-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-eth/vlan-[id]
Affected MO: sys/switch-[id]/border-fc/fcoeestc-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-fc/fcoesan-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-fc/fcoesan-pc-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-fc/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-fc/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-fc/slot-[slotId]-aggr-port-[aggrPortId]/fcoeestc-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-fc/slot-[slotId]-aggr-port-[aggrPortId]/fcoesan-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-fc/vlan-[id]
Affected MO: sys/switch-[id]/ethlanflowmon/flowexporter-netflow-[name]/vlan-[id]
Affected MO: sys/switch-[id]/ethlanflowmon/vc-[id]/vlan-[id]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/pc-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/fcoeestc-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesan-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/vc-[id]/vlan-[id]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/vlan-[id]
Affected MO: sys/switch-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/switch-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/switch-[id]/phys/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/phys/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/phys/slot-[slotId]-aggr-port-[aggrPortId]/fcoeestc-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/phys/slot-[slotId]-aggr-port-[aggrPortId]/fcoesan-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/sanmon-fc/mon-[name]/fcoesan-pc-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/sanmon-fc/mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/sanmon-fc/mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/sanmon-fc/mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/fcoeestc-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/sanmon-fc/mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesan-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/sanmon-fc/mon-[name]/vc-[id]/vlan-[id]
fltCimcvmediaActualMountEntryVmediaMountFailed
Fault Code: F1404
Message
Server [chassisId]/[slotId] (service profile: [assignedToDn]) vmedia mapping [mappingName] has failed.Server [id] (service profile: [assignedToDn]) vmedia mapping [mappingName] has failed.Server [chassisId]/[slotId]/[serverInstanceId] (service profile: [assignedToDn]) vmedia mapping [mappingName] has failed.
Explanation
None set.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the mount related details(remote server ip, port, path & file is reachable) and reack the server.
Fault Details
Cause: vmedia-mount-inaccessible
mibFaultName: fltCimcvmediaActualMountEntryVmediaMountFailed
moClass: cimcvmedia:ActualMountEntry
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/boardController/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/sas-expander-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/slot-[id]/boardController/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/fex-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/rack-unit-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/switch-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
fltEquipmentTpmSlaveTpm
Fault Code: F1439
Message
Server [chassisId]/[slotId], has a TPM present on the Slave Board which will be unoperational.
Explanation
This fault indicates the TPM is present on the slave board but it cannot be used by the server. In the case of an aggregate blade server, only the master board’s TPM can be used.
Recommended Action
There is no impact on server functionality although TPM from the slave board can be removed and used on a different server.
Fault Details
Cause: tpm-on-slave-board
mibFaultName: fltEquipmentTpmSlaveTpm
Affected MO: sys/chassis-[id]/blade-[slotId]/board/Tpm-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/Tpm-[id]
Affected MO: sys/rack-unit-[id]/board/Tpm-[id]
fltStorageMezzFlashLifeConfiguration-error
Fault Code: F1448
Message
Flash Life on server [chassisId]/[slotId] flashStatus: [flashStatus]
Explanation
This fault occurs when UCSM is not able to retrieve the Fusion-io life left due to an error.
Recommended Action
If you see this fault, take the following actions:
Step 1 Upgrade Fusion-io Firmware.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: configuration-error
mibFaultName: fltStorageMezzFlashLifeConfigurationError
moClass: storage:MezzFlashLife
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/flash-life-
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/flash-life-
Affected MO: sys/chassis-[id]/storage-[type]-[id]/flash-life-
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/flash-life-
fltStorageMezzFlashLifeDegraded
Fault Code: F1449
Message
Flash Life on server [chassisId]/[slotId] flashStatus: [flashStatus]
Explanation
This fault occurs when the Fusion-io life left is 10 percent or less.
Recommended Action
If you see this fault, take the following actions:
Step 1 Continue to monitor the the Fusion-io life left and if it reaches 0 percent, the adapter might revert to read-only.
Fault Details
Cause: equipment-degraded
mibFaultName: fltStorageMezzFlashLifeDegraded
moClass: storage:MezzFlashLife
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/flash-life-
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/flash-life-
Affected MO: sys/chassis-[id]/storage-[type]-[id]/flash-life-
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/flash-life-
fltStorageFlexFlashControllerMismatch
Fault Code: F1450
Message
FlexFlash Controller [id] on server [chassisId]/[slotId] has SD cards with different sizes.FlexFlash Controller [id] on server [id] has SD cards with different sizes.
Explanation
This fault occurs when the flexflash SD Cards dont match in size.
Recommended Action
If you see this fault, take the following action:
Step 1 Remove one of the existing cards and replace it with another card that has the same size as the unremoved one.
Fault Details
Cause: equipment-unhealthy
mibFaultName: fltStorageFlexFlashControllerMismatch
moClass: storage:FlexFlashController
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-flexflash-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-flexflash-[id]
Affected MO: sys/rack-unit-[id]/board/storage-flexflash-[id]
fltStorageFlexFlashDriveUnhealthy
Fault Code: F1451
Message
FlexFlash Drive [id] on server [chassisId]/[slotId] is unhealthy. Reason: [operQualifierReason] Status: [operationState]FlexFlash Drive [id] on server [id] is unhealthy. Reason: [operQualifierReason] Status: [operationState]
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
Cause: equipment-unhealthy
mibFaultName: fltStorageFlexFlashDriveUnhealthy
moClass: storage:FlexFlashDrive
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-flexflash-[id]/card-[slotNumber]/drive-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-flexflash-[id]/card-[slotNumber]/drive-[name]
Affected MO: sys/rack-unit-[id]/board/storage-flexflash-[id]/card-[slotNumber]/drive-[name]
fltStorageFlexFlashCardUnhealthy
Fault Code: F1452
Message
FlexFlash Card [slotNumber] on server [chassisId]/[slotId] is unhealthy. Reason: [cardHealth]FlexFlash Card [slotNumber] on server [id] is unhealthy. Reason: [cardHealth]
Explanation
This fault occurs when the Flex Flash card is unhealthy.
Recommended Action
If you see this fault, take the following action:
Step 1 Determine if the Flex Flash controller supports auto-sync; auto-sync is currently configured; and the Flex Flash controller is currently building the RAID group. If the RAID group is being built, wait until the RAID group has been synchronized. Note that building the RAID-1 mirror may take multiple hours, depending on how much I/O the host OS is generating.
Step 2 If the above action did not resolve the problem, configure Flex Flash auto-sync and wait until the RAID group has been rebuilt, which may take multiple hours.
Step 3 If the above action did not resolve the problem, reset the Flex Flash controller.
Step 4 If the above action did not resolve the problem, reformat the SD cards.
Step 5 Re-acknowledge the server by setting the Flex Flash scrub policy to yes. Please note that this action will erase all data in the card(s)
Step 6 Verify the health of the card. If the above action did not resolve the issue, replace the card
Fault Details
Cause: equipment-unhealthy
mibFaultName: fltStorageFlexFlashCardUnhealthy
moClass: storage:FlexFlashCard
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-flexflash-[id]/card-[slotNumber]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-flexflash-[id]/card-[slotNumber]
Affected MO: sys/rack-unit-[id]/board/storage-flexflash-[id]/card-[slotNumber]
fltPoolElementDuplicatedAssigned
Fault Code: F1453
Message
ID is duplicated assigned for multiple servers(Check UCSC for details)
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
Cause: duplicated-assigned
mibFaultName: fltPoolElementDuplicatedAssigned
fltMgmtInterfaceNamedInbandVlanUnresolved
Fault Code: F1454
Message
[configMessage]
Explanation
This fault occurs if there is an issue in Inband interface configuration.
Recommended Action
If you see this fault check if the VLAN configured on Inband IP is created and the VLAN is present in the Inband Profile or IP address is configured
Fault Details
Cause: named-inband-vlan-unresolved
mibFaultName: fltMgmtInterfaceNamedInbandVlanUnresolved
Affected MO: org-[name]/ls-[name]/iface-[mode]
Affected MO: org-[name]/tier-[name]/ls-[name]/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/sas-expander-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/slot-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/iface-[mode]
Affected MO: sys/fex-[id]/mgmt/iface-[mode]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/iface-[mode]
Affected MO: sys/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/mgmt/iface-[mode]
Affected MO: sys/switch-[id]/mgmt/iface-[mode]
fltMgmtInterfaceInbandUnsupportedServer
Fault Code: F1455
Message
[configMessage]
Explanation
This fault occurs if there is an issue in Inband interface configuration.
Recommended Action
If you see this fault check if the VLAN configured on Inband IP is created and the VLAN is present in the Inband Profile or IP address is configured
Fault Details
Cause: inband-unsupported-server
mibFaultName: fltMgmtInterfaceInbandUnsupportedServer
Affected MO: org-[name]/ls-[name]/iface-[mode]
Affected MO: org-[name]/tier-[name]/ls-[name]/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/sas-expander-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/slot-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/iface-[mode]
Affected MO: sys/fex-[id]/mgmt/iface-[mode]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/iface-[mode]
Affected MO: sys/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/mgmt/iface-[mode]
Affected MO: sys/switch-[id]/mgmt/iface-[mode]
fltMgmtInterfaceInbandUnsupportedFirmware
Fault Code: F1456
Message
[configMessage]
Explanation
This fault occurs if there is an issue in Inband interface configuration.
Recommended Action
If you see this fault check if the VLAN configured on Inband IP is created and the VLAN is present in the Inband Profile or IP address is configured
Fault Details
Cause: unsupported-cimc-firmware
mibFaultName: fltMgmtInterfaceInbandUnsupportedFirmware
Affected MO: org-[name]/ls-[name]/iface-[mode]
Affected MO: org-[name]/tier-[name]/ls-[name]/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/sas-expander-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/slot-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/iface-[mode]
Affected MO: sys/fex-[id]/mgmt/iface-[mode]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/iface-[mode]
Affected MO: sys/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/mgmt/iface-[mode]
Affected MO: sys/switch-[id]/mgmt/iface-[mode]
fltSwVlanPortNsResourceStatusWarning
Fault Code: F1464
Message
Total Available Vlan-Port Count on switch [switchId] is below 10%
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltSwVlanPortNsResourceStatusWarning
Affected MO: sys/switch-[id]/vlan-port-ns
fltNetworkElementMemoryerror
Fault Code: F1465
Message
Fabric Interconnect [id] memory less than expected! Total Memory: [totalMemory] and Expected Memory: [expectedMemory]
Explanation
This fault occurs when the total memory on FI is less than expected.
Recommended Action
If you see this fault, take the following actions:
Step 1 You will need to do a manual physical inspection of the DIMMs on the FI. Try removing and reinserting the DIMMs, and verify the Total Memory. If this does not resolve the issue, one of the DIMMs has gone bad and needs to be replaced.
Step 2 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltNetworkElementMemoryerror
Affected MO: sys/switch-[id]
fltComputePhysicalAdapterMismatch
Fault Code: F1467
Message
Server [id] (service profile: [assignedToDn]) has invalid adapter combinatonServer [chassisId]/[slotId] (service profile: [assignedToDn]) has invalid adapter combination
Explanation
This fault typically occurs because Cisco UCS Manager has detected that the server has an invalid combination of Cisco VICs.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the valid adapter combinations are installed configuration.
Step 2 Reacknowledge the server.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltComputePhysicalAdapterMismatch
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltNetworkElementRemoved
Fault Code: F1493
Message
Fabric Interconnect [id] operability: [operability]
Explanation
This fault occurs when the fabric interconnect is removed in a clustering setup.
Recommended Action
If you see this fault, take the following actions:
Step 1 Reinsert the removed fabric interconnect back into the chassis (applicable to UCS-Mini only).
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltNetworkElementRemoved
Affected MO: sys/switch-[id]
fltPowerBudgetChassisPsuMixedMode
Fault Code: F1498
Message
Chassis [id] has a mix of high-line and low-line PSU input power sources.
Explanation
This fault occurs when there is a mix of high-line and low-line PSU input power source.
Recommended Action
If you see this fault, change all the PSU input power sources to have same mode
Fault Details
mibFaultName: fltPowerBudgetChassisPsuMixedMode
Affected MO: sys/chassis-[id]/blade-[slotId]/budget
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/budget
Affected MO: sys/chassis-[id]/budget
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/budget
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/budget
Affected MO: sys/fex-[id]/budget
Affected MO: sys/rack-unit-[id]/budget
Affected MO: sys/rack-unit-[id]/ext-board-[id]/budget
Affected MO: sys/switch-[id]/budget
fltPowerBudgetPowerBudgetUnavailable
Fault Code: F1499
Message
Insufficient power available to power-on server [chassisId]/[slotId]Insufficient power available to power-on server [id]
Explanation
This fault occurs when there is not enough power available to be allocated to a server.
Recommended Action
If you see this fault, take the following actions:
Step 1 Consider increasing the group cap.
Step 2 Consider increasing the power available to a chassis by increasing PSUs connected and/or changing the PSU policy.
Step 3 Reduce the number of blade servers powered-on and/or reduce the number of chassis in the Cisco UCS instance.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: power-budget-unavailable
mibFaultName: fltPowerBudgetPowerBudgetUnavailable
Affected MO: sys/chassis-[id]/blade-[slotId]/budget
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/budget
Affected MO: sys/chassis-[id]/budget
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/budget
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/budget
Affected MO: sys/fex-[id]/budget
Affected MO: sys/rack-unit-[id]/budget
Affected MO: sys/rack-unit-[id]/ext-board-[id]/budget
Affected MO: sys/switch-[id]/budget
fltStorageLocalDiskInaccessible
Fault Code: F1519
Message
Storage LocalDisk [id] is inaccessible. Reason: [operQualifierReason]
Explanation
This fault occurs when the local disk is abnormal or bad. The fault description will contain the physical drive state, which indicates the reason for the degradation.
Recommended Action
If you see this fault, take the following actions:
Step 1 Resolve the fault on LocalDisk
Fault Details
Cause: equipment-inaccessible
mibFaultName: fltStorageLocalDiskInaccessible
moClass: storage:LocalDisk
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]
fltEquipmentChassisInvalid-fru
Fault Code: F1558
Message
Chassis [id] has a empty value for FRU identity reported by CMC.
Explanation
This fault typically occurs when the FRU information for a chassis has empty value.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the capability catalog in Cisco UCS Manager is up to date. If necessary, update the catalog.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentChassisInvalidFru
moClass: equipment:Chassis
Affected MO: sys/chassis-[id]
fltEquipmentSwitchIOCardRemoved
Fault Code: F1559
Message
[side] FI IOM [chassisId]/[id] ([switchId]) is removed
Explanation
This fault typically occurs because an FI I/O module is removed from the chassis. In a cluster configuration, the chassis fails over to the other FI I/O module. For a standalone configuration, the chassis associated with the FI I/O module loses network connectivity. This is a critical fault because it can result in the loss of network connectivity and disrupt data traffic through the FI I/O module.
Recommended Action
If you see this fault, take the following actions:
Step 1 Reinsert the FI I/O module and configure the fabric-interconnect ports connected to it as server ports and wait a few minutes to see if the fault clears.
Step 2 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentSwitchIOCardRemoved
moClass: equipment:SwitchIOCard
Affected MO: sys/chassis-[id]/sw-slot-[id]
fltEquipmentSwitchIOCardThermalProblem
Fault Code: F1560
Message
[side] FI IOM [chassisId]/[id] ([switchId]) operState: [operState]
Explanation
This fault occurs when there is a thermal problem on an FI I/O module. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco UCS equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco UCS equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the FI I/O module.
Step 2 Review the Cisco UCS Site Preparation Guide to ensure the FI I/O modules have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco UCS chassis are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Replace faulty FI I/O modules.
Step 8 Use the Cisco UCS power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 9 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentSwitchIOCardThermalProblem
moClass: equipment:SwitchIOCard
Affected MO: sys/chassis-[id]/sw-slot-[id]
fltEquipmentSwitchIOCardThermalThresholdNonCritical
Fault Code: F1561
Message
[side] FI IOM [chassisId]/[id] ([switchId]) temperature: [thermal]
Explanation
This fault occurs when the temperature of an FI I/O module has exceeded a non-critical threshold value, but is still below the critical threshold. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco UCS equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco UCS equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
- If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the FI I/O module.
Step 2 Review the Cisco UCS Site Preparation Guide to ensure the chassis and FI I/O modules have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco UCS chassis and FI I/O module are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Use the Cisco UCS power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 8 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentSwitchIOCardThermalThresholdNonCritical
moClass: equipment:SwitchIOCard
Affected MO: sys/chassis-[id]/sw-slot-[id]
fltEquipmentSwitchIOCardThermalThresholdCritical
Fault Code: F1562
Message
[side] FI IOM [chassisId]/[id] ([switchId]) temperature: [thermal]
Explanation
This fault occurs when the temperature of an FI I/O module has exceeded a critical threshold value. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco UCS equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco UCS equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
- If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the FI I/O module.
Step 2 Review the Cisco UCS Site Preparation Guide to ensure the chassis and FI I/O modules have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco UCS chassis and FI I/O module are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Replace the faulty FI I/O modules.
Step 8 Use the Cisco UCS power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 9 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentSwitchIOCardThermalThresholdCritical
moClass: equipment:SwitchIOCard
Affected MO: sys/chassis-[id]/sw-slot-[id]
fltEquipmentSwitchIOCardThermalThresholdNonRecoverable
Fault Code: F1563
Message
[side] FI IOM [chassisId]/[id] ([switchId]) temperature: [thermal]
Explanation
This fault occurs when the temperature of an FI I/O module has been out of the operating range, and the issue is not recoverable. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco UCS equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco UCS equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
- If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the FI I/O module.
Step 2 Review the Cisco UCS Site Preparation Guide to ensure the chassis and FI I/O modules have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco UCS chassis and FI I/O module are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Replace the faulty FI I/O modules.
Step 8 Use the Cisco UCS power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 9 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentSwitchIOCardThermalThresholdNonRecoverable
moClass: equipment:SwitchIOCard
Affected MO: sys/chassis-[id]/sw-slot-[id]
fltEquipmentSwitchIOCardPeerDisconnected
Fault Code: F1564
Message
FI IOM [chassisId]/[id] ([switchId]) peer connectivity: [peerCommStatus]
Explanation
This fault typically occurs when an FI I/O module is unable to communicate with its peer FI I/O module.
Recommended Action
If you see this fault, take the following actions:
Step 1 Wait a few minutes to see if the fault clears. This is typically a temporary issue, and can occur after a firmware upgrade.
Step 2 If the fault does not clear after a few minutes, remove and reinsert the FI I/O module.
Step 3 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-disconnected
mibFaultName: fltEquipmentSwitchIOCardPeerDisconnected
moClass: equipment:SwitchIOCard
Affected MO: sys/chassis-[id]/sw-slot-[id]
fltEquipmentSwitchIOCardIdentity
Fault Code: F1565
Message
[side] FI IOM [chassisId]/[id] ([switchId]) has a malformed FRU
Explanation
This fault typically occurs when the FRU information for an FI I/O module is corrupted or malformed.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the capability catalog in Cisco UCS Manager is up to date. If necessary, update the catalog.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentSwitchIOCardIdentity
moClass: equipment:SwitchIOCard
Affected MO: sys/chassis-[id]/sw-slot-[id]
fltEquipmentSwitchIOCardCpuThermalThresholdCritical
Fault Code: F1566
Message
[side] FI IOM [chassisId]/[id] ([switchId]) processor temperature exceeded the limit
Explanation
This fault typically occurs when the processor temperature in FI-IOM exceeds the limit.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the FI I/O module.
Step 2 Review the Cisco UCS Site Preparation Guide to ensure the chassis and FI I/O modules have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco UCS chassis and FI I/O module are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused blade servers and rack servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Replace the faulty FI I/O modules.
Step 8 Use the Cisco UCS power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 9 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentSwitchIOCardCpuThermalThresholdCritical
moClass: equipment:SwitchIOCard
Affected MO: sys/chassis-[id]/sw-slot-[id]
fltStorageLocalDiskThermalIssueCritical
Fault Code: F1604
Message
Local disk [id] on server [chassisId]/[slotId] has thermal issue: [thermal]Local disk [id] on server [id] has thermal issue: [thermal]Local disk [id] on chassis [id] has thermal issue: [thermal]Local disk [id] on storage enclosure [id] has thermal issue: [thermal]
Explanation
This fault occurs when the local drive is experiencing a critical thermal issue.
Recommended Action
If you see this fault, take the following actions:
Step 1 If only one drive is too hot, replace the drive.
Step 2 If many drives are too hot, remove the server.
Step 3 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltStorageLocalDiskThermalIssueCritical
moClass: storage:LocalDisk
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]
fltStorageLocalDiskThermalIssueNonRecoverable
Fault Code: F1605
Message
Local disk [id] on server [chassisId]/[slotId] has thermal issue: [thermal]Local disk [id] on server [id] has thermal issue: [thermal]Local disk [id] on chassis [id] has thermal issue: [thermal]Local disk [id] on storage enclosure [id] has thermal issue: [thermal]
Explanation
This fault occurs when the local drive is experiencing a non-recoverable thermal issue.
Recommended Action
If you see this fault, take the following actions:
Step 1 If only one drive is too hot, replace the drive.
Step 2 If many drives are too hot, remove the server.
Step 3 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltStorageLocalDiskThermalIssueNonRecoverable
moClass: storage:LocalDisk
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]
fltStorageLocalDiskNot-supported
Fault Code: F1606
Message
Local disk [id] is not supported on server [chassisId]/[slotId]Local disk [id] is not supported on server [id]Local disk [id] is not supported on chassis [id]Local disk [id] is not supported on storage enclosure [id]
Explanation
This fault occurs when the local disk is not supported on this server or chassis.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltStorageLocalDiskNotSupported
moClass: storage:LocalDisk
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]
fltFabricComputeMSlotEpMisplacedInChassisSlot
Fault Code: F1616
Message
Server, vendor([vendor]), model([model]), serial([serial]) in slot [chassisId]/[slotId]/[serverInstanceId] presence: [presence]
Explanation
This fault typically occurs when Cisco UCS Manager detects a server in a slot that does not match what was previously equipped in the slot.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the server was decommissioned, reacknowledge the server.
Step 2 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFabricComputeMSlotEpMisplacedInChassisSlot
moClass: fabric:ComputeMSlotEp
Affected MO: fabric/server/chassis-[chassisId]/cart-slot-[slotId]/ins-[serverInstanceId]
fltFabricComputeMSlotEpServerIdentificationProblem
Fault Code: F1617
Message
Problem identifying server [serverInstanceId] in slot [chassisId]/[slotId]
Explanation
This fault typically occurs when Cisco UCS Manager encountered a problem identifying the server in a cartridge slot.
Recommended Action
If you see this fault, take the following actions:
Step 1 Remove and reinsert the cartridge.
Step 2 Reacknowledge the server.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: server-identification-problem
mibFaultName: fltFabricComputeMSlotEpServerIdentificationProblem
moClass: fabric:ComputeMSlotEp
Affected MO: fabric/server/chassis-[chassisId]/cart-slot-[slotId]/ins-[serverInstanceId]
fltFabricCartridgeSlotEpMisplacedInChassisSlot
Fault Code: F1618
Message
Cartridge, vendor([vendor]), model([model]), serial([serial]) in slot [chassisId]/[slotId] presence: [presence]
Explanation
This fault typically occurs when Cisco UCS Manager detects a cartridge in a chassis slot that does not match what was previously equipped in the slot.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the previous cartridge was intentionally removed and a new one was inserted, reacknowledge the cartridge.
Step 2 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFabricCartridgeSlotEpMisplacedInChassisSlot
moClass: fabric:CartridgeSlotEp
Affected MO: fabric/server/chassis-[chassisId]/cart-slot-[slotId]
fltStorageControllerNot-supported
Fault Code: F1620
Message
Controller [id] is not supported on chassis [id]
Explanation
This fault occurs when the storage controller is not supported on this chassis.
Recommended Action
Check whether the storage controller is in the list of supported controllers. Replace with a supported controller.
Fault Details
mibFaultName: fltStorageControllerNotSupported
moClass: storage:Controller
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]
fltStorageVirtualDriveDeployment-failure
Fault Code: F1621
Message
Virtual drive [name] deployment failure. Reason: [configQualifierReason]
Explanation
This fault indicates that UCSM found resources for a virtual drive but was unable to deploy it.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify the presence and health of disks that are used for the virtual drive deployment.
Step 2 Alternatively, the fault can be cleared by deleting the DasScsiLun mo
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inoperable
mibFaultName: fltStorageVirtualDriveDeploymentFailure
moClass: storage:VirtualDrive
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/vd-container-[id]/vd-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/vd-container-[id]/vd-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/vd-[id]
Affected MO: sys/chassis-[id]/vd-container-[id]/vd-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/rack-unit-[id]/vd-container-[id]/vd-[id]
fltStorageVirtualDriveMissing
Fault Code: F1622
Message
Virtual drive [name] missing
Explanation
This fault indicates that the virtual drive was successfully deployed but it was later deleted.
Recommended Action
If you see this fault, take the following actions:
Step 1 The presence of this fault means that UCSM will attempt to re-create the virtual drive when the next association FSM occurs.
Step 2 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltStorageVirtualDriveMissing
moClass: storage:VirtualDrive
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/vd-container-[id]/vd-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/vd-container-[id]/vd-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/vd-[id]
Affected MO: sys/chassis-[id]/vd-container-[id]/vd-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/rack-unit-[id]/vd-container-[id]/vd-[id]
fltStorageVirtualDriveMismatch
Fault Code: F1623
Message
Virtual drive [name] mismatch. Reason: [configQualifierReason]
Explanation
This fault indicates that the virtual drive was successfully deployed but later, UCSM detected that the virtual drive did not match the configuration expected by UCSM.
Recommended Action
If you see this fault, take the following actions:
Step 1 To modify the DasScsiLun mo to match the actual virtual drive.
Step 2 To use an LSI host utility to restore the virtual drive to the original configuration.
Step 3 To to replace the failed or missing drive and use an LSI host utility to restore the virtual drive to the original configuration.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: configuration-mismatch
mibFaultName: fltStorageVirtualDriveMismatch
moClass: storage:VirtualDrive
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/vd-container-[id]/vd-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/vd-container-[id]/vd-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/vd-[id]
Affected MO: sys/chassis-[id]/vd-container-[id]/vd-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/rack-unit-[id]/vd-container-[id]/vd-[id]
fltStorageVDMemberEpMismatch
Fault Code: F1624
Message
Virtual drive member [id] in a mismatched state. Reason: [operQualifierReason]
Explanation
This fault indicates that a physical drive that is a member of the virtual drive is in a mismatched state.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the local disk referred by the VdMemberEp to see if it’s expected beheavior.
Step 2 If not expected, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: configuration-mismatch
mibFaultName: fltStorageVDMemberEpMismatch
moClass: storage:VDMemberEp
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/vd-[id]/member-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/vd-container-[id]/vd-[id]/member-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/vd-[id]/member-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/vd-container-[id]/vd-[id]/member-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/vd-[id]/member-[id]
Affected MO: sys/chassis-[id]/vd-container-[id]/vd-[id]/member-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/vd-[id]/member-[id]
Affected MO: sys/rack-unit-[id]/vd-container-[id]/vd-[id]/member-[id]
fltFirmwareBootUnitFirmwareBootFailed
Fault Code: F1627
Message
Endpoint firmware went faulty.
Explanation
This fault typically occurs for the following reasons: when firmware activation fails, or if end-point booted up and went faulty.
- Firmware activation failed.
- The version of firmware running on the end-point went faulty.
Recommended Action
If you see this fault, take the following actions:
Step 1 Go to FSM tab or in cli for the endpoint on which the fault is raised and review the error description for the reason that the activation failed.
Step 2 If the FSM failed, review the error message in the FSM.
Step 3 If possible, correct the problem described in the error message.
Step 4 If the problem persists, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFirmwareBootUnitFirmwareBootFailed
moClass: firmware:BootUnit
Affected MO: capabilities/ep/mgmt-ext/fw-boot-def/bootunit-[type]
Affected MO: capabilities/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/graphics-card-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/onboard-device-[deviceType]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/onboard-device-[deviceType]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/graphics-card-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/onboard-device-[deviceType]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/onboard-device-[deviceType]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/psu-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/sas-expander-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/sas-expander-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/sas-expander-[id]/onboard-device-[deviceType]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/slot-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/onboard-device-[deviceType]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/fex-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/fex-[id]/psu-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/graphics-card-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/onboard-device-[deviceType]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/onboard-device-[deviceType]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/psu-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/switch-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/switch-[id]/psu-[id]/fw-boot-def/bootunit-[type]
fltAaaDefaultAuthDefaultAuthNotDeployed
Fault Code: F1668
Message
DefaultAuth can’t be deployed. Error: [configStatusMessage]
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
Cause: defaultauth-config-error
mibFaultName: fltAaaDefaultAuthDefaultAuthNotDeployed
Affected MO: sys/auth-realm/default-auth
fltAaaDomainDomainNotDeployed
Fault Code: F1669
Message
Domain [name] can’t be deployed. Error: [configStatusMessage]
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
Cause: domain-config-error
mibFaultName: fltAaaDomainDomainNotDeployed
Affected MO: sys/auth-realm/domain-[name]
fltLsServerFAULT
Fault Code: F1671
Message
The UUID stored in Service Profile [name] does not match the UUID stored in server [pnDn]
Explanation
Because of a recent UCSM upgrade that fixed a bug relating to a change in Smbios endianness, UCSM inventory has an updated UUID that matches the UUID stored in BIOS, but the UUID stored in the Service Profile has not been updated and hence does not match
Recommended Action
If you see this fault, take any one of the following actions:
Step 1 Disassociate and reassociate the service profile
Step 2 Decommision and recommision the server
Step 3 Set a new UUID for the server
Fault Details
mibFaultName: fltLsServerFAULT
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]
fltMgmtBackupLocal Internal backup failed
Fault Code: F1672
Message
Local Internal backup failed while upgrade. Please re-trigger a manual backup.
Explanation
This fault occurs when the local internal backup failed while upgrade
Recommended Action
If you see this fault, take the following actions:
Step 1 Please take a configuration backup
Fault Details
Cause: local-internal-backup-failed
mibFaultName: fltMgmtBackupLocalInternalBackupFailed
Affected MO: sys/backup-[hostname]
fltVnicEtherCdn-config-not-applied
Fault Code: F1680
Message
CDN can not be applied for vnic [name] in Service Profile [name]
Explanation
This fault typically occurs when CDN of a vnic is not applied due to adaptor hardware or firmware incompatibility
Recommended Action
If you see this fault, take the following actions:
Step 1 For a CDN supported adaptor, upgrade the firmware to a version where it is supported
Step 2 For an unsupported adaptor, place the vnics manually on the supported adaptor only
Step 3 In case CDN is not intended to be used, disable CDN in bios policy
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltVnicEtherCdnConfigNotApplied
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]
fltComputePhysicalConnectivityDown
Fault Code: F1681
Message
Connectivity between the CIMC and one of the FIs is down. Connectivity may be down for expected reasons (e.g. FI/CIMC firmware upgrade).Connectivity between the CIMC and one of the FIs is down. Connectivity may be down for expected reasons (e.g. FI/CIMC firmware upgrade).Connectivity between the CIMC and one of the FIs is down. Connectivity may be down for expected reasons (e.g. FI/CIMC firmware upgrade).
Explanation
This fault occurs if there are connectivity issues between the server’s CIMC and one or both of the FIs. Please note that this management path loss will not impact the underlying OS communications.
Recommended Action
If you see this fault, take the following actions:
Step 1 Wait a few minutes to see if the fault clears. This is typically a temporary issue, and can occur during or after a firmware upgrade.
Step 2 If the fault does not clear after a brief time, please reset the CIMC. This will not impact OS communications.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inaccessible
mibFaultName: fltComputePhysicalConnectivityDown
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltStorageSasExpanderInoperable
Fault Code: F1685
Message
SAS Expander [id]/[id] operability: [operability]. Reason [operQualifierReason].
Explanation
This fault indicates that a SAS Expander is not operable.
Recommended Action
If you see this fault, take the following actions:
Step 1 create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inoperable
mibFaultName: fltStorageSasExpanderInoperable
moClass: storage:SasExpander
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]
Affected MO: sys/chassis-[id]/sas-expander-[id]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]
fltStorageSasExpanderAccessibility-problem
Fault Code: F1686
Message
SAS Expander [id]/[id] operability: [operability]. Reason [operQualifierReason].
Explanation
This fault indicates that a SAS Expander is unreachable.
Recommended Action
If you see this fault, take the following actions:
Step 1 create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-accessibility-problem
mibFaultName: fltStorageSasExpanderAccessibilityProblem
moClass: storage:SasExpander
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]
Affected MO: sys/chassis-[id]/sas-expander-[id]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]
fltStorageSasExpanderDegraded
Fault Code: F1687
Message
SAS Expander [id]/[id] operability: [operability]. Reason [uplinkStateReason].
Explanation
This fault indicates that a link in SAS Expander is in sub-optimal state.
Recommended Action
If you see this fault, take the following actions:
Step 1 create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-degraded
mibFaultName: fltStorageSasExpanderDegraded
moClass: storage:SasExpander
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]
Affected MO: sys/chassis-[id]/sas-expander-[id]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]
fltStorageLocalDiskLink-degraded
Fault Code: F1688
Message
Local Disk [id]/[id]/[id] link state: [linkState]. Reason [linkStateReason].
Explanation
This fault indicates that a link in storage Local disk is sub-optimal.
Recommended Action
If you see this fault, take the following actions:
Step 1 create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-link-degraded
mibFaultName: fltStorageLocalDiskLinkDegraded
moClass: storage:LocalDisk
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]
fltFabricFcSanNumOfVsanExceedLimit
Fault Code: F1694
Message
VSAN count for [dn] exceeds the limit.
Explanation
This fault occurs when the number of VSANs exceed limit.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltFabricFcSanNumOfVsanExceedLimit
Affected MO: fabric/san/[id]
fltSwVlanPortNsCompressedSetsExhaustedWarning
Fault Code: F1700
Message
Network configuration on switch [switchId] resulted in using up ALL of the optimization sets supported by hardware.
Explanation
Cisco UCS Manager raises this fault when the fabric interconnect exhaust all of the Optimizatino sets to be programmed in hardware. This fault does not indicate any problem in the configuration. However, some current or future configuration may cause some error and appropriate alert will be shown. Only when you see any other alters, there could be a cause of concern.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check if any configuration error is shown in UCSM and take actions recommended by those errors if any.
Fault Details
Cause: compr-sets-exhausted
mibFaultName: fltSwVlanPortNsCompressedSetsExhaustedWarning
Affected MO: sys/switch-[id]/vlan-port-ns
fltNetworkElementKernelMemCricitalThreshold
Fault Code: F1701
Message
Fabric Interconnect [id] kernel low memory free reached critical level: [kernelMemFree] (MB).
Explanation
This fault occurs when the kernel memory for the FI is below 100MB
Recommended Action
If you see this fault:
Step 1 Kernel LowFree memory dropped below the minimal watermark of 100 MB. Please collect tech-support info and contact Cisco Customer Support (TAC).
Step 2 Also can log the memory footprint of the FI via "show system internal kernel meminfo"
Fault Details
Cause: kernel-mem-critical-threshold
mibFaultName: fltNetworkElementKernelMemCricitalThreshold
Affected MO: sys/switch-[id]
fltFlowctrlItemFlowctrlconfig
Fault Code: F1702
Message
Flow Control Policy: [name], has unsupported configuration. Priority Pause and Send/Receive Flow-control cannot be ON together, this policy configuration won’t be applied until corrected.
Explanation
This fault occurs when the flow-control policy has an unsupported config. This fault will be raised during upgrade/import operations.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check the flow-control policy named in the fault message and correct the configuration on it to a supported configuration.
Fault Details
Cause: unsupported-policy-config
mibFaultName: fltFlowctrlItemFlowctrlconfig
Affected MO: fabric/lan/flowctrl/policy-[name]
fltNetworkElementSystemshutdown
Fault Code: F1703
Message
Fabric Interconnect [id] will reboot in 120 sec
Explanation
This fault typically occurs when fans get removed or broken and the fabric interconnect will reboot.
Recommended Action
If you see this fault, take the following actions:
Step 1 Replace or Insert with a good fan.
Fault Details
mibFaultName: fltNetworkElementSystemshutdown
Affected MO: sys/switch-[id]
fltMgmtHealthStatusHealthWarningIssue
Fault Code: F1704
Message
[healthQualifier] : Please check the Health tab for more details
Explanation
This fault occurs when there is a warning health issue of a component (BMC/CIMC..)
Recommended Action
If you see this fault, take the following actions:
Step 1 create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltMgmtHealthStatusHealthWarningIssue
moClass: mgmt:HealthStatus
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/health
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/mgmt/health
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/mgmt/health
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/health
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/health
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/health
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/mgmt/health
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/health
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/health
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/health
Affected MO: sys/chassis-[id]/boardController/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/health
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/mgmt/health
Affected MO: sys/chassis-[id]/mgmt/health
Affected MO: sys/chassis-[id]/sas-expander-[id]/mgmt/health
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/health
Affected MO: sys/chassis-[id]/slot-[id]/boardController/mgmt/health
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/health
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/mgmt/health
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/mgmt/health
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/health
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/health
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/health
Affected MO: sys/fex-[id]/mgmt/health
Affected MO: sys/fex-[id]/slot-[id]/mgmt/health
Affected MO: sys/mgmt/health
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/health
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/mgmt/health
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/mgmt/health
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/health
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/health
Affected MO: sys/rack-unit-[id]/boardController/mgmt/health
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/mgmt/health
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/health
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/health
Affected MO: sys/rack-unit-[id]/mgmt/health
Affected MO: sys/switch-[id]/health
Affected MO: sys/switch-[id]/mgmt/health
fltMgmtHealthStatusHealthMinorIssue
Fault Code: F1705
Message
[healthQualifier] : Please check the Health tab for more details
Explanation
This fault occurs when there is a minor health issue of a component (BMC/CIMC..)
Recommended Action
If you see this fault, take the following actions:
Step 1 create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltMgmtHealthStatusHealthMinorIssue
moClass: mgmt:HealthStatus
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/health
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/mgmt/health
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/mgmt/health
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/health
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/health
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/health
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/mgmt/health
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/health
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/health
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/health
Affected MO: sys/chassis-[id]/boardController/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/health
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/mgmt/health
Affected MO: sys/chassis-[id]/mgmt/health
Affected MO: sys/chassis-[id]/sas-expander-[id]/mgmt/health
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/health
Affected MO: sys/chassis-[id]/slot-[id]/boardController/mgmt/health
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/health
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/mgmt/health
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/mgmt/health
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/health
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/health
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/health
Affected MO: sys/fex-[id]/mgmt/health
Affected MO: sys/fex-[id]/slot-[id]/mgmt/health
Affected MO: sys/mgmt/health
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/health
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/mgmt/health
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/mgmt/health
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/health
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/health
Affected MO: sys/rack-unit-[id]/boardController/mgmt/health
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/mgmt/health
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/health
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/health
Affected MO: sys/rack-unit-[id]/mgmt/health
Affected MO: sys/switch-[id]/health
Affected MO: sys/switch-[id]/mgmt/health
fltMgmtHealthStatusHealthMajorIssue
Fault Code: F1706
Message
[healthQualifier] : Please check the Health tab for more details[healthQualifier] : [description]
Explanation
This fault occurs when there is a major health issue of a component (CMC/CIMC/FI)
Recommended Action
If you see this fault, take the following actions:
Step 1 If it is on CMC/CIMC component, create a show tech-support file and contact Cisco TAC.
Step 2 If it is on FI with fault description starting with "SER Uncorrectable Error", then switch reboot is recommended. If this does not fix the problem, contact TAC.
Fault Details
mibFaultName: fltMgmtHealthStatusHealthMajorIssue
moClass: mgmt:HealthStatus
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/health
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/mgmt/health
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/mgmt/health
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/health
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/health
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/health
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/mgmt/health
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/health
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/health
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/health
Affected MO: sys/chassis-[id]/boardController/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/health
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/mgmt/health
Affected MO: sys/chassis-[id]/mgmt/health
Affected MO: sys/chassis-[id]/sas-expander-[id]/mgmt/health
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/health
Affected MO: sys/chassis-[id]/slot-[id]/boardController/mgmt/health
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/health
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/mgmt/health
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/mgmt/health
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/health
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/health
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/health
Affected MO: sys/fex-[id]/mgmt/health
Affected MO: sys/fex-[id]/slot-[id]/mgmt/health
Affected MO: sys/mgmt/health
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/health
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/mgmt/health
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/mgmt/health
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/health
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/health
Affected MO: sys/rack-unit-[id]/boardController/mgmt/health
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/mgmt/health
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/health
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/health
Affected MO: sys/rack-unit-[id]/mgmt/health
Affected MO: sys/switch-[id]/health
Affected MO: sys/switch-[id]/mgmt/health
fltMgmtHealthStatusHealthCriticalIssue
Fault Code: F1707
Message
[healthQualifier] : Please check the Health tab for more details
Explanation
This fault occurs when there is a critical health issue of a component (BMC/CIMC)
Recommended Action
If you see this fault, take the following actions:
Step 1 create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltMgmtHealthStatusHealthCriticalIssue
moClass: mgmt:HealthStatus
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/health
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/mgmt/health
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/mgmt/health
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/health
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/health
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/health
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/mgmt/health
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/health
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/health
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/health
Affected MO: sys/chassis-[id]/boardController/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/health
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/health
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/mgmt/health
Affected MO: sys/chassis-[id]/mgmt/health
Affected MO: sys/chassis-[id]/sas-expander-[id]/mgmt/health
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/health
Affected MO: sys/chassis-[id]/slot-[id]/boardController/mgmt/health
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/health
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/mgmt/health
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/mgmt/health
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/health
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/health
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/health
Affected MO: sys/fex-[id]/mgmt/health
Affected MO: sys/fex-[id]/slot-[id]/mgmt/health
Affected MO: sys/mgmt/health
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/health
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/mgmt/health
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/mgmt/health
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/health
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/health
Affected MO: sys/rack-unit-[id]/boardController/mgmt/health
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/mgmt/health
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/health
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/health
Affected MO: sys/rack-unit-[id]/mgmt/health
Affected MO: sys/switch-[id]/health
Affected MO: sys/switch-[id]/mgmt/health
fltComputePhysicalDeprecated
Fault Code: F1708
Message
Server [id] (service profile: [assignedToDn]) discovery: [discovery] Hardware Deprecated or FRU not supportedServer [chassisId]/[slotId] (service profile: [assignedToDn]) discovery: [discovery] Hardware Deprecated or FRU not supportedServer [chassisId]/[slotId]/[serverInstanceId] (service profile: [assignedToDn]) discovery: [discovery] Hardware Deprecated or FRU not supported
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltComputePhysicalDeprecated
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalAdapterFirmwareNeedsUpdate
Fault Code: F1709
Message
Some of the adapters in Server [chassisId]/[slotId] needs firmware update to operate in 40G mode.These adapters are currently configured in 4x10G mode
Explanation
None set.
Recommended Action
If you see this fault, take the following actions:
Step 1 Update the Adapter Firmware in the blade and acknowledge the Chassis
Fault Details
Cause: connectivity-problem
mibFaultName: fltComputePhysicalAdapterFirmwareNeedsUpdate
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalIdentityUnestablishableOrDeprecated
Fault Code: F1710
Message
Server [id] (service profile: [assignedToDn]) has an invalid FRU. The server is either deprecated or not supportedServer [chassisId]/[slotId] (service profile: [assignedToDn]) has an invalid FRU. The server is either deprecated or not supported
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
Cause: identity-unestablishable
mibFaultName: fltComputePhysicalIdentityUnestablishableOrDeprecated
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltEquipmentIOCardDeprecated
Fault Code: F1713
Message
[side] IOM [chassisId]/[id] ([switchId]) is either deprecated or not supported
Explanation
This fault typically occurs when the I/O module is deprecated.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that the capability catalog in Cisco UCS Manager is the right version. If necessary, update the catalog.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentIOCardDeprecated
moClass: equipment:IOCard
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltFabricSwChPhEpUncleanConfiguration
Fault Code: F1719
Message
Chassis [chassisId] has unclean configuration
Explanation
This fault typically occurs when there is a unclean configuration after decommission the Chassis.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify that if service profile is completely disassociate.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltFabricSwChPhEpUncleanConfiguration
Affected MO: fabric/server/chassis-ep-ven-[vendor]-mod[model]-ser-[serial]
fltFabricComputeSlotEpNotSupportedInChassisSlot
Fault Code: F1720
Message
Server in slot [chassisId]/[slotId] is not supported on this platform
Explanation
This fault typically occurs when Cisco UCS Manager detects a server in a chassis slot is not supported on the current platform.
Recommended Action
If you see this fault, take the following actions:
Step 1 Remove the server.
Fault Details
Cause: equipment-inoperable
mibFaultName: fltFabricComputeSlotEpNotSupportedInChassisSlot
moClass: fabric:ComputeSlotEp
Affected MO: fabric/server/chassis-[chassisId]/slot-[slotId]
fltFabricDceSwSrvEpDown
Fault Code: F1721
Message
Chassis discovery detected on port [slotId]/[portId]. UCS-FI-M-6324 platform does not support chassis discovery on non-scalability port
Explanation
This fault typically occurs when a non-scalability port is configured as server port to discover non-Primary Chassis on UCS-FI-6324 platform.
Recommended Action
If you see this fault, try the alternate action described below:
Step 1 Unconfigure the server ports and move the cables from the regular port(s) on FI to scalability ports.
Fault Details
Cause: unsupported-config
mibFaultName: fltFabricDceSwSrvEpDown
moClass: fabric:DceSwSrvEp
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-port-[portId]
fltStorageLocalDiskThermalIssueNonCritical
Fault Code: F1731
Message
Local disk [id] on server [chassisId]/[slotId] has thermal issue: [thermal]Local disk [id] on server [id] has thermal issue: [thermal]Local disk [id] on storage enclosure [id] has thermal issue: [thermal]
Explanation
This fault occurs when the local drive is experiencing a non critical thermal issue.
Recommended Action
If you see this fault, monitor other environmental events related to this server and ensure the temperature ranges are within recommended ranges. If the issue persists, take the following actions:
Step 1 If only one drive is too hot, replace the drive.
Step 2 If many drives are too hot, remove the server.
Step 3 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltStorageLocalDiskThermalIssueNonCritical
moClass: storage:LocalDisk
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]
fltStorageLocalDiskFailed
Fault Code: F1732
Message
Local disk [id] failed on server [chassisId]/[slotId]Local disk [id] failed on server [id]Local disk [id] failed on storage enclosure [id]
Explanation
This fault occurs when a disk goes bad.
Recommended Action
If you see this fault, take the following action:
Step 1 Replace disk or send it to hardware team for further investigation.
Fault Details
mibFaultName: fltStorageLocalDiskFailed
moClass: storage:LocalDisk
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]
fltEquipmentSystemIOControllerRemoved
Fault Code: F1744
Message
System IO Controller [chassisId]/[id] is removed
Explanation
This fault typically occurs because a System IO Controller is removed from the colusa chassis.This is a critical fault because it can result in the loss of network connectivity.
Recommended Action
If you see this fault, take the following actions:
Step 1 Reinsert the System IO Controller and configure the fabric-interconnect ports connected to it as server ports and wait a few minutes to see if the fault clears.
Step 2 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentSystemIOControllerRemoved
moClass: equipment:SystemIOController
Affected MO: sys/chassis-[id]/slot-[id]
fltComputeRackUnitFanSpeedConfigurationFailed
Fault Code: F1745
Message
Server [id] (service profile: [assignedToDn]) Fan Speed Policy failed: [fanSpeedConfigStatus]
Explanation
This fault typically occurs because the set fan speed policy is not sufficient
Recommended Action
If you see this fault, take the following actions:
Step 1 Increase the value of the fan speed policy in power control policy to a higher value.
Fault Details
Cause: equipment-degraded
mibFaultName: fltComputeRackUnitFanSpeedConfigurationFailed
moClass: compute:RackUnit
Affected MO: sys/rack-unit-[id]
fltFabricEthLanNumOfVLANCompGrpExceedLimit
Fault Code: F1748
Message
VLAN compression group count for [dn] exceeds the limit.
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
Cause: vlan-comp-grp-count-exceeds-limit
mibFaultName: fltFabricEthLanNumOfVLANCompGrpExceedLimit
Affected MO: fabric/lan/[id]
fltFabricMulticastPolicySameOrEmptyPeerQuerierIp
Fault Code: F1749
Message
FI-B querier IP [querierIpAddrPeer] is empty or same as FI-A.
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
Cause: fi-b-querier-ip-empty-or-same-as-primary
mibFaultName: fltFabricMulticastPolicySameOrEmptyPeerQuerierIp
moClass: fabric:MulticastPolicy
Affected MO: org-[name]/mc-policy-[name]
fltAdaptorUnitDeprecated
Fault Code: F1753
Message
Adapter [id] in server [id] may be deprecated or not supported.Adapter [id] in server [chassisId]/[slotId] may be deprecated or not supported.Adapter [id] in server [chassisId]/[slotId]/[serverInstanceId] may be deprecated or not supported.
Explanation
This fault typically occurs because Cisco UCS Manager has detected an adapter that is deprecated in the current release.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify if the adapter is supported in the release and not deprecated
Step 2 If the above action(s) did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltAdaptorUnitDeprecated
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]
fltMgmtInterfaceInbandPinningInvalid
Fault Code: F1754
Message
[configMessage]
Explanation
This fault occurs if the server interface is not pinned to any uplink.
Recommended Action
If you see this fault check if there is any operational uplink that is configured with all VLANs specified in the Inband Profile
Fault Details
mibFaultName: fltMgmtInterfaceInbandPinningInvalid
Affected MO: org-[name]/ls-[name]/iface-[mode]
Affected MO: org-[name]/tier-[name]/ls-[name]/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/sas-expander-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/slot-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/iface-[mode]
Affected MO: sys/fex-[id]/mgmt/iface-[mode]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/iface-[mode]
Affected MO: sys/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/mgmt/iface-[mode]
Affected MO: sys/switch-[id]/mgmt/iface-[mode]
fltEtherPIoInvalid-sfp
Fault Code: F1755
Message
Port [slotId]/[portId] on FI-[switchId] does not support CR4 (passive copper) cable
Explanation
: 3GFI donner ports (last 6 40G ports) do not support "negotiate auto". When an CR4 (passive coper mode) cable is inserted, this fault will be raised
Recommended Action
: If you see this fault, please replace a fabric cable into the 40G port.
Fault Details
Cause: unsupported-transceiver
mibFaultName: fltEtherPIoInvalidSfp
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]
fltNetworkOperLevelExtravif
Fault Code: F1756
Message
Fabric Interconnect [id]: Number of VIFs configured exceeds the max limit on the FI: Number of VIFs configured: [vifCount] and Max VIFs allowed: [maxVifCount]
Explanation
This fault occurs when the fabric interconnect has more number of Virtual Interfaces (VIF) than what is supported.
Recommended Action
If you see this fault, take the following actions:
Step 1 It is recommended that operator should delete the extra Virtual Interfaces(VIF) than are there in the FI. System may appear to be normally functioning even with these extra VIFs in place. However there may be performance issues observed as the system is operating above the recommended scale limits..
Step 2 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltNetworkOperLevelExtravif
moClass: network:OperLevel
Affected MO: sys/switch-[id]/oper-level
fltNetworkElementDeprecated
Fault Code: F1757
Message
Fabric Interconnect [id] operability: [operability]
Explanation
This fault typically occurs when the fabric interconnect model is deprecated.
Recommended Action
If you see this fault, take the following actions:
Step 1 Downgrade to the previous work release and plan your upgrade with a non-deprecated fabric interconnect model.
Fault Details
Cause: equipment-deprecated
mibFaultName: fltNetworkElementDeprecated
Affected MO: sys/switch-[id]
fltFabricNetGroupNativeVlanNotFound
Fault Code: F1758
Message
Native VLAN [nativeNet] for VLAN group [name] cannot be found among the member vlans in the VLAN group.
Explanation
This fault typically occurs when the native VLAN of the VLAN group is not found among the member vlans in the VLAN group.
Recommended Action
If you see this fault, take the following action:
Step 1 Create the member Vlan in the VLAN group.
Step 2 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: native-vlan-not-found
mibFaultName: fltFabricNetGroupNativeVlanNotFound
Affected MO: fabric/lan/[id]/net-group-[name]
Affected MO: fabric/lan/net-group-[name]
fltEquipmentChassisChassislimit-exceeded
Fault Code: F1761
Message
Chassis limit exceeded for this platform with the addition of chassis [id]
Explanation
This fault typically occurs because Cisco UCS Manager detects that the number of chassis present in the system exceeds the maximum number supported on the platform.
Recommended Action
If you see this fault, take the following actions:
Step 1 Verify the maximum number of chassis supported in the platform from the release notes. If the number of chassis in the system is less than the maximum number supported, and the fault is still observed, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: chassis-limit-exceeded
mibFaultName: fltEquipmentChassisChassislimitExceeded
moClass: equipment:Chassis
Affected MO: sys/chassis-[id]
fltMgmtEntityDevice-1-shared-storage-connect error
Fault Code: F1766
Message
device [chassis1], error connecting to shared-storage management interface
Explanation
This fault occurs in an unlikely event that the shared storage selected for writing the cluster state is not accessible. This fault is typically a transient fault. You might see this fault when one of the following occurs: (a) the Fabric Interconnect boots, (b) the IO Module is reset, (c) the rack server is reboot, or (d) system is upgraded/downgraded. If this fault is not cleared after the system returns to normal operation following the reboot/reset/upgrade/downgrade, then it may affect the full HA functionality of the Fabric Interconnect cluster.
Recommended Action
If this fault is not cleared even after the system returns to normal operation, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: device-shared-storage-error
mibFaultName: fltMgmtEntityDevice1SharedStorageConnectError
Affected MO: sys/mgmt-entity-[id]
fltMgmtEntityDevice-2-shared-storage-connect error
Fault Code: F1767
Message
device [chassis2], error connecting to shared-storage management interface
Explanation
This fault occurs in an unlikely event that the shared storage selected for writing the cluster state is not accessible. This fault is typically a transient fault. You might see this fault when one of the following occurs: (a) the Fabric Interconnect boots, (b) the IO Module is reset, (c) the rack server is reboot, or (d) system is upgraded/downgraded. If this fault is not cleared after the system returns to normal operation following the reboot/reset/upgrade/downgrade, then it may affect the full HA functionality of the Fabric Interconnect cluster.
Recommended Action
If this fault is not cleared even after the system returns to normal operation, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: device-shared-storage-error
mibFaultName: fltMgmtEntityDevice2SharedStorageConnectError
Affected MO: sys/mgmt-entity-[id]
fltMgmtEntityDevice-3-shared-storage-connect error
Fault Code: F1768
Message
device [chassis3], error connecting to shared-storage management interface
Explanation
This fault occurs in an unlikely event that the shared storage selected for writing the cluster state is not accessible. This fault is typically a transient fault. You might see this fault when one of the following occurs: (a) the Fabric Interconnect boots, (b) the IO Module is reset, (c) the rack server is reboot, or (d) system is upgraded/downgraded. If this fault is not cleared after the system returns to normal operation following the reboot/reset/upgrade/downgrade, then it may affect the full HA functionality of the Fabric Interconnect cluster.
Recommended Action
If this fault is not cleared even after the system returns to normal operation, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: device-shared-storage-error
mibFaultName: fltMgmtEntityDevice3SharedStorageConnectError
Affected MO: sys/mgmt-entity-[id]
fltSwEthLanBorderVlan-limit-exceeded
Fault Code: F1778
Message
Maximum allowed VLANs limit has been exceeded, please delete the extra VLANs to ensure proper system functioning.
Explanation
This fault typically occurs after upgrade, if the maximum allowed VLANs limit has changed in the new release.
Recommended Action
If you see this fault, take the following actions:
Step 1 Delete the extra VLANs in order to meet the limits defined in the new release. Current count and max allowed count details can be seen in UCSM CLI under ’system/upgrade-validation’ scope.
Step 2 Note: The VLANs associated with FCoE VSANs are also counted towards the overall max VLAN limit.
Step 3 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: max-vlan-limit-exceeded
mibFaultName: fltSwEthLanBorderVlanLimitExceeded
Affected MO: sys/switch-[id]/border-eth
fltMgmtEntityMgmt-db-version-mismatch
Fault Code: F1781
Message
Management database version mismatch detected failover may not complete
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
Cause: replication-failure
mibFaultName: fltMgmtEntityMgmtDbVersionMismatch
Affected MO: sys/mgmt-entity-[id]
fltEquipmentTpmTpmMismatch
Fault Code: F1784
Message
Server [id], has a TPM mismatch.
Explanation
This fault is raised due to incompatible CPU/TPM combination
Recommended Action
If you see this fault, please check the TPM model used
Step 1 Read fault summary and determine course of action.
Fault Details
mibFaultName: fltEquipmentTpmTpmMismatch
Affected MO: sys/chassis-[id]/blade-[slotId]/board/Tpm-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/Tpm-[id]
Affected MO: sys/rack-unit-[id]/board/Tpm-[id]
fltEquipmentSharedIOModuleInaccessible
Fault Code: F1792
Message
Shared IO Module [id] of chassis [chassisId] is offline
Explanation
This fault typically occurs because a Shared I/O module has lost its connection to the fabric interconnects. This is a critical fault because it can result in the loss of network connectivity and disrupt data traffic.
Recommended Action
If you see this fault, take the following actions:
Step 1 Wait a few minutes to see if the fault clears. This is typically a temporary issue, and can occur after a firmware upgrade.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inaccessible
mibFaultName: fltEquipmentSharedIOModuleInaccessible
moClass: equipment:SharedIOModule
Affected MO: sys/chassis-[id]/shared-io-module
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module
fltEquipmentChassisInaccessible-b
Fault Code: F1793
Message
Chassis not reachable from B side
Explanation
This fault typically occurs because a Shared I/O module has lost its connection to B side FI. This is a major fault because it can result in the loss of network connectivity and disrupt data traffic on B side.
Recommended Action
If you see this fault, take the following actions:
Step 1 Wait a few minutes to see if the fault clears. This is typically a temporary issue, and can occur after a firmware upgrade.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inaccessible
mibFaultName: fltEquipmentChassisInaccessibleB
moClass: equipment:Chassis
Affected MO: sys/chassis-[id]
fltEquipmentChassisInaccessible-a
Fault Code: F1794
Message
Chassis not reachable from A side
Explanation
This fault typically occurs because a Shared I/O module has lost its connection to A side FI. This is a major fault because it can result in the loss of network connectivity and disrupt data traffic on A side.
Recommended Action
If you see this fault, take the following actions:
Step 1 Wait a few minutes to see if the fault clears. This is typically a temporary issue, and can occur after a firmware upgrade.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inaccessible
mibFaultName: fltEquipmentChassisInaccessibleA
moClass: equipment:Chassis
Affected MO: sys/chassis-[id]
fltEquipmentSystemIOControllerThermalProblem
Fault Code: F1795
Message
System IO Controller [id] on Chassis [chassisId], operState: [operState]
Explanation
This fault occurs when there is a thermal problem on an System I/O Controller module. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco UCS equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco UCS equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the I/O module.
Step 2 Review the Cisco UCS Site Preparation Guide to ensure the I/O modules have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco UCS chassis are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Replace faulty I/O modules.
Step 8 Use the Cisco UCS power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 9 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentSystemIOControllerThermalProblem
moClass: equipment:SystemIOController
Affected MO: sys/chassis-[id]/slot-[id]
fltEquipmentSystemIOControllerUnacknowledged
Fault Code: F1796
Message
System IO Controller [id] on Chassis [chassisId] is re-inserted. Acknowledge the SIOC
Explanation
System IO Controller is in un-acknowledged state. Cisco UCS Manager raises this fault when any of the following scenarios occur:
- Cisco UCS Manager detects a that the SystemIOController is re-inserted.
Recommended Action
If you see this fault, take the following actions:
Step 1 Reacknowledge the chassis.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-unacknowledged
mibFaultName: fltEquipmentSystemIOControllerUnacknowledged
moClass: equipment:SystemIOController
Affected MO: sys/chassis-[id]/slot-[id]
fltEquipmentIOCardBackPlanePortProblem
Fault Code: F1797
Message
One or more of the Backplane Ports are not up in IOM [chassisId]/[id] connected to FI [switchId]
Explanation
This fault occurs when one or any of the backplane ports are failed:
Recommended Action
If you see this fault, check the status of the backplane ports
Fault Details
Cause: backplane-port-problem
mibFaultName: fltEquipmentIOCardBackPlanePortProblem
moClass: equipment:IOCard
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltEquipmentSwitchIOCardBackPlanePortProblem
Fault Code: F1798
Message
One or more of the Backplane Ports are not up in IOM [chassisId]/[id] connected to FI [switchId]
Explanation
This fault occurs when one or any of the backplane ports are failed:
Recommended Action
If you see this fault, check the status of the backplane ports
Fault Details
Cause: backplane-port-problem
mibFaultName: fltEquipmentSwitchIOCardBackPlanePortProblem
moClass: equipment:SwitchIOCard
Affected MO: sys/chassis-[id]/sw-slot-[id]
fltEquipmentFexBackPlanePortProblem
Fault Code: F1799
Message
One or more of the Backplane Ports are not up in FEX [id] connected to FI [switchId]
Explanation
This fault occurs when one or any of the backplane ports are failed:
Recommended Action
If you see this fault, check the status of the backplane ports
Fault Details
Cause: backplane-port-problem
mibFaultName: fltEquipmentFexBackPlanePortProblem
Affected MO: sys/fex-[id]
fltFabricFcZoneProfileSwitch-mode-disabled
Fault Code: F1825
Message
FC User zones cannot be deployed because FI is not running in FC switch mode.
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
Cause: configuration-error
mibFaultName: fltFabricFcZoneProfileSwitchModeDisabled
moClass: fabric:FcZoneProfile
Affected MO: fabric/fc-estc/zone-profile-[name]
fltFabricFcUserZoneConfigFailure
Fault Code: F1826
Message
FC User Zone [name] configuration failed as it reached max user defined or system zone configuration limit
Explanation
Cisco UCS Manager cannot successfully deploy the FC User defined Zone due to a lack of resource that meet the named qualifier. This fault typically occurs as a result of exceeding the user defined zone limit or system zone limit
Recommended Action
If you see this fault, take the following actions:
Step 1 If the User defined zone count is above the limit, then free up any unused user defined zone.
Step 2 If the User defined zone count is below the limit, but the system FC Zone count exceeds 8000, then try to free up unused zones from the service profile.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: configuration-failure
mibFaultName: fltFabricFcUserZoneConfigFailure
moClass: fabric:FcUserZone
Affected MO: fabric/fc-estc/zone-profile-[name]/zone-[name]
fltStorageEnclosureThermalIssueNonCritical
Fault Code: F1831
Message
HDD MotherBoard on [id] has a thermal problem: [thermal]
Explanation
This fault occurs when there is a thermal problem on an HDD MotherBoard module. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco UCS equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco UCS equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the I/O module.
Step 2 Review the Cisco UCS Site Preparation Guide to ensure the I/O modules have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco UCS chassis are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Replace faulty I/O modules.
Step 8 Use the Cisco UCS power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 9 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltStorageEnclosureThermalIssueNonCritical
moClass: storage:Enclosure
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]
Affected MO: sys/chassis-[id]/enc-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]
fltStorageEnclosureThermalIssueCritical
Fault Code: F1832
Message
HDD MotherBoard on [id] has a thermal problem: [thermal]
Explanation
This fault occurs when there is a thermal problem on an HDD MotherBoard module. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco UCS equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco UCS equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the I/O module.
Step 2 Review the Cisco UCS Site Preparation Guide to ensure the I/O modules have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco UCS chassis are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Replace faulty I/O modules.
Step 8 Use the Cisco UCS power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 9 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltStorageEnclosureThermalIssueCritical
moClass: storage:Enclosure
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]
Affected MO: sys/chassis-[id]/enc-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]
fltStorageEnclosureThermalIssueNonRecoverable
Fault Code: F1833
Message
HDD MotherBoard on [id] has a thermal problem: [thermal]
Explanation
This fault occurs when there is a thermal problem on an HDD MotherBoard module. Be aware of the following possible contributing factors:
- Temperature extremes can cause Cisco UCS equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
- Cisco UCS equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the product specifications to determine the temperature operating range of the I/O module.
Step 2 Review the Cisco UCS Site Preparation Guide to ensure the I/O modules have adequate airflow, including front and back clearance.
Step 3 Verify that the air flows on the Cisco UCS chassis are not obstructed.
Step 4 Verify that the site cooling system is operating properly.
Step 5 Power off unused servers.
Step 6 Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.
Step 7 Replace faulty I/O modules.
Step 8 Use the Cisco UCS power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.
Step 9 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltStorageEnclosureThermalIssueNonRecoverable
moClass: storage:Enclosure
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]
Affected MO: sys/chassis-[id]/enc-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]
fltStorageControllerDegraded
Fault Code: F1834
Message
Controller [id] on server [chassisId]/[slotId] is degraded. Reason: [operQualifierReason]Controller [id] on server [id] is degraded. Reason: [operQualifierReason]Controller [id] on chassis [id] is degraded. Reason: [operQualifierReason]
Explanation
This fault occurs when the storage controller is degraded.
Recommended Action
For NVMe SSD. If the problem persists, replace the controller.
Fault Details
Cause: equipment-degraded
mibFaultName: fltStorageControllerDegraded
moClass: storage:Controller
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]
fltStorageSasExpanderLink-misconnect
Fault Code: F1835
Message
SAS Expander [id]/[id] uplink state: [uplinkState]. Reason [uplinkStateReason].
Explanation
This fault indicates that a SAS Expander uplink state is misconnect.
Recommended Action
If you see this fault, take the following actions:
Step 1 create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-link-misconnect
mibFaultName: fltStorageSasExpanderLinkMisconnect
moClass: storage:SasExpander
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]
Affected MO: sys/chassis-[id]/sas-expander-[id]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]
fltStorageSasExpanderLink-degraded
Fault Code: F1836
Message
SAS Expander [id]/[id] uplink state: [uplinkState]. Reason [uplinkStateReason].
Explanation
This fault indicates that a SAS Expander uplink state is sub-optimal.
Recommended Action
If you see this fault, take the following actions:
Step 1 create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-link-degraded
mibFaultName: fltStorageSasExpanderLinkDegraded
moClass: storage:SasExpander
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]
Affected MO: sys/chassis-[id]/sas-expander-[id]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]
fltStorageEnclosureMissing
Fault Code: F1837
Message
Enclosure [id]/[id] is missing.
Explanation
This fault indicates that a removable enclosure is missing.
Recommended Action
If you see this fault, take the following actions:
Step 1 Run remove operation on that enclosure to cleanup.
Fault Details
mibFaultName: fltStorageEnclosureMissing
moClass: storage:Enclosure
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]
Affected MO: sys/chassis-[id]/enc-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]
fltStorageEnclosureFru-empty
Fault Code: F1838
Message
HDD Expansion Tray [id]/[id] FRU could not be identified.
Explanation
This fault indicates that a HDD expansion tray is replaced and FRU details need to be fetched
Recommended Action
If you see this fault, take the following actions:
Step 1 Reset the active CMC
Fault Details
Cause: equipment-fru-missing
mibFaultName: fltStorageEnclosureFruEmpty
moClass: storage:Enclosure
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]
Affected MO: sys/chassis-[id]/enc-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]
fltStorageEnclosureDiskSlotEpMissing
Fault Code: F1839
Message
Disk Slot [id]/[id]/[id] is missing.
Explanation
This fault indicates that a disk slot is missing.
Recommended Action
If you see this fault, take the following actions:
Step 1 If the slot is part of a removable enclosure, run remove operation on that enclosure to cleanup.
Step 2 If the slot is part of a non-removeable, enclsoure, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltStorageEnclosureDiskSlotEpMissing
moClass: storage:EnclosureDiskSlotEp
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-slot-[id]
fltStorageEnclosureDiskSlotEpEquipment-inoperable
Fault Code: F1840
Message
Disk Slot [id]/[id]/[id] operability: [operability]. Reason [operQualifierReason].
Explanation
This fault indicates that a disk slot is not operable.
Recommended Action
If you see this fault, take the following actions:
Step 1 create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: equipment-inoperable
mibFaultName: fltStorageEnclosureDiskSlotEpEquipmentInoperable
moClass: storage:EnclosureDiskSlotEp
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-slot-[id]
fltStorageEnclosureDiskSlotEpChassis-spare
Fault Code: F1841
Message
Chassis spare disk in slot [id]/[id]/[id] is assigned to a controller.
Explanation
This fault indicates that a disk slot marked as chassis spare is assigned to a controller.
Recommended Action
If you see this fault, take the following actions:
Step 1 Replace the bad disk(s)
Fault Details
Cause: equipment-unavailable
mibFaultName: fltStorageEnclosureDiskSlotEpChassisSpare
moClass: storage:EnclosureDiskSlotEp
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-slot-[id]
fltStorageEnclosureDiskSlotEpHotspare-unsupported
Fault Code: F1842
Message
Slot [id]/[id]/[id] ownership is automatically unassigned since the controller(s) does not support chassis global hot spare.
Explanation
This fault indicates that a disk slot ownership is automatically unassigned since the controller does not chassis wide hot spare.
Recommended Action
If you see this fault, take the following actions:
Step 1 Insert server(s) with hot spare supported storage controllers (or) change the ownership in disk zoning policy
Fault Details
Cause: equipment-hotspare-unsupported
mibFaultName: fltStorageEnclosureDiskSlotEpHotspareUnsupported
moClass: storage:EnclosureDiskSlotEp
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-slot-[id]
fltStorageEnclosureDiskSlotEpSharing-unsupported
Fault Code: F1843
Message
Slot [id]/[id]/[id] ownership is automatically unassigned since the controller(s) does not support sharing.
Explanation
This fault indicates that a disk slot ownership is automatically unassigned since the controller does not support sharing.
Recommended Action
If you see this fault, take the following actions:
Step 1 Insert server(s) with sharing supported storage controllers (or) change the ownership in disk zoning policy
Fault Details
Cause: equipment-ownership-unsupported
mibFaultName: fltStorageEnclosureDiskSlotEpSharingUnsupported
moClass: storage:EnclosureDiskSlotEp
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-slot-[id]
fltStorageEnclosureDiskSlotEpIoe-ownership-unassigned
Fault Code: F1844
Message
Slot [id]/[id]/[id] ownership is automatically unassigned since IO Expander with second controller is present in place of server in first slot.
Explanation
This fault indicates that a disk slot ownership is automatically unassigned since IO Expander with second controller is present in place of server in first slot.
Recommended Action
If you see this fault, take the following actions:
Step 1 Insert server in first slot (or) change the ownership in disk zoning policy
Fault Details
Cause: equipment-ioe-ownership-unassigned
mibFaultName: fltStorageEnclosureDiskSlotEpIoeOwnershipUnassigned
moClass: storage:EnclosureDiskSlotEp
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-slot-[id]
fltStorageEnclosureDiskSlotEpHddslot-server2-ownership-unassigned
Fault Code: F1845
Message
Slot [id]/[id]/[id] ownership is automatically unassigned since HDD Expansion Tray is present in place of server in second slot.
Explanation
This fault indicates that a disk slot ownership is automatically unassigned since HDD Expansion Tray is present in place of server in second slot.
Recommended Action
If you see this fault, take the following actions:
Step 1 Insert server in second slot (or) change the ownership in disk zoning policy
Fault Details
Cause: equipment-hddslot-server2-ownership-unassigned
mibFaultName: fltStorageEnclosureDiskSlotEpHddslotServer2OwnershipUnassigned
moClass: storage:EnclosureDiskSlotEp
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-slot-[id]
fltEquipmentChassisProfileFailed
Fault Code: F1846
Message
Chassis Profile [name] failed
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltEquipmentChassisProfileFailed
moClass: equipment:ChassisProfile
Affected MO: org-[name]/cp-[name]
Affected MO: org-[name]/cp-tier-[name]/cp-[name]
fltEquipmentChassisProfileDiscoveryFailed
Fault Code: F1847
Message
Chassis Profile [name] discovery failed
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltEquipmentChassisProfileDiscoveryFailed
moClass: equipment:ChassisProfile
Affected MO: org-[name]/cp-[name]
Affected MO: org-[name]/cp-tier-[name]/cp-[name]
fltEquipmentChassisProfileConfigFailure
Fault Code: F1848
Message
Chassis Profile [name] configuration failed due to [chassisConfigIssues],[storageConfigIssues]
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
Cause: configuration-failure
mibFaultName: fltEquipmentChassisProfileConfigFailure
moClass: equipment:ChassisProfile
Affected MO: org-[name]/cp-[name]
Affected MO: org-[name]/cp-tier-[name]/cp-[name]
fltEquipmentChassisProfileRemoved
Fault Code: F1849
Message
Chassis Profile [name] underlying resource removed
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltEquipmentChassisProfileRemoved
moClass: equipment:ChassisProfile
Affected MO: org-[name]/cp-[name]
Affected MO: org-[name]/cp-tier-[name]/cp-[name]
fltEquipmentChassisProfileInaccessible
Fault Code: F1850
Message
Chassis Profile [name] cannot be accessed
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
Cause: equipment-inaccessible
mibFaultName: fltEquipmentChassisProfileInaccessible
moClass: equipment:ChassisProfile
Affected MO: org-[name]/cp-[name]
Affected MO: org-[name]/cp-tier-[name]/cp-[name]
fltEquipmentChassisProfileAssociationFailed
Fault Code: F1851
Message
Chassis Profile [name] association failed for [chassisDn]
Explanation
The Chassis Profile could not be associated with the Chassis
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
Cause: association-failed
mibFaultName: fltEquipmentChassisProfileAssociationFailed
moClass: equipment:ChassisProfile
Affected MO: org-[name]/cp-[name]
Affected MO: org-[name]/cp-tier-[name]/cp-[name]
fltEquipmentChassisProfileUnassociated
Fault Code: F1852
Message
Chassis Profile [name] is not associated
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltEquipmentChassisProfileUnassociated
moClass: equipment:ChassisProfile
Affected MO: org-[name]/cp-[name]
Affected MO: org-[name]/cp-tier-[name]/cp-[name]
fltFabricNetGroupRefNetSanGroupUnresolvable
Fault Code: F1873
Message
Network/SAN group does not exist or not permitted
Explanation
This fault occurs when NetGroup/SanGroup referenced by the netGroupRef/SanGroupRef doesn’t exist or netGroupRef/SanGroupRef MO are not in the same Org as Network Group/San Group.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check if the NetGroup/SanGroup exists if not create one.
Step 2 Check if the NetGroup/SanGroup is in the same Org as netGroupRef/SanGroupRef.
Fault Details
Cause: network-san-group-does-not-exist
mibFaultName: fltFabricNetGroupRefNetSanGroupUnresolvable
moClass: fabric:NetGroupRef
Affected MO: fabric/lan/profiles/vnic-[name]/net-group-ref-[name]
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]/net-group-ref-[name]
Affected MO: org-[name]/lan-conn-templ-[name]/net-group-ref-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]/net-group-ref-[name]
Affected MO: org-[name]/san-conn-templ-[name]/net-group-ref-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sas-expander-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sas-expander-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/sas-expander-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/sas-expander-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/sas-expander-[id]/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/sas-expander-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/slot-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/slot-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/slot-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/slot-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/fex-[id]/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/fex-[id]/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/fex-[id]/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/fex-[id]/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/fex-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/fex-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/fex-[id]/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/fex-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/board/sas-expander-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/rack-unit-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/switch-[id]/ethlanflowmon/vc-[id]/net-group-ref-[name]
Affected MO: sys/switch-[id]/ethlanflowmon/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/vc-[id]/net-group-ref-[name]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/switch-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/net-group-ref-[name]
Affected MO: sys/switch-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/switch-[id]/mgmt/fabric-[switchId]/vc-[id]/net-group-ref-[name]
Affected MO: sys/switch-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
Affected MO: sys/switch-[id]/sanmon-fc/mon-[name]/vc-[id]/net-group-ref-[name]
Affected MO: sys/switch-[id]/sanmon-fc/mon-[name]/vc-[id]/vlan-cmc[id]/net-group-ref-[name]
fltEtherPIoUnknownServerDevice
Fault Code: F1889
Message
[slotId]/[portId] on FI-[switchId] is connected by a unknown server device
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltEtherPIoUnknownServerDevice
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]
fltEtherPIoMisconfigureForServerDevice
Fault Code: F1890
Message
[slotId]/[portId] on FI-[switchId] is connected by a ucs server device, and may config as a server port
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltEtherPIoMisconfigureForServerDevice
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]
fltEtherPIoInterfaceMismatch
Fault Code: F1891
Message
Port [slotId]/[portId] on FI-[switchId] does not match with breakout cable
Explanation
: 3GFI tranceiver type does not match interface type, this fault will be raised
Recommended Action
: If you see this fault, please change interface to breakout.
Fault Details
Cause: transceiver-mismatch
mibFaultName: fltEtherPIoInterfaceMismatch
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]
fltAdaptorUnitPci-config-issue
Fault Code: F1892
Message
Adapter [id] in server [chassisId]/[slotId] is not visible to host
Explanation
The adapter is not visible to the host OS. Cisco UCS Manager raises this fault when any of the following scenarios occur:
- The PCIe connecitivity to the chassis adapter is not configured for the server.
- Corresponding SIOC is missing.
- Single Server Dual SIOC connectivity is applied, and CIMC/BIOS firmware version does not support this feature.
Recommended Action
If you see this fault, take the following actions:
Step 1 Check if the corresponding SIOC is inserted in the chassis.
Step 2 Check if CIMC/BIOS are running recommended firmware version.
Step 3 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltAdaptorUnitPciConfigIssue
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]
fltNetworkElementEvacuationon
Fault Code: F1893
Message
Fabric Interconnect [id] operEvacState: [operEvacState]
Explanation
This fault typically occurs when the fabric interconnect is evacuated.
Recommended Action
If you see this fault, take the following actions:
Step 1 Ensure that the Evacuation option is switched off for the fabric interconnects.
Fault Details
mibFaultName: fltNetworkElementEvacuationon
Affected MO: sys/switch-[id]
fltNetworkLimitUnicast-mac
Fault Code: F1894
Message
No. of unicast mac addresses ([actualCount]) on switch [id] has reached the upper limit([upperLimit]). Will get cleared when the count reaches the lower limit ([lowerLimit])
Explanation
This fault typically occurs when number of unicast mac addreses on the fabric interconnect has exreched an upper threshold. It gets cleared when the numbers reaches a lower threshold
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
Cause: unicast-mac-exhausted
mibFaultName: fltNetworkLimitUnicastMac
Affected MO: sys/switch-[id]/limit-type-[type]-asic-[asicNumber]
fltNetworkLimitMulticast-mac
Fault Code: F1895
Message
No. of multicast mac addresses ([actualCount]) on switch [id] has reached the upper limit([upperLimit]). Will get cleared when the count reaches the lower limit ([lowerLimit])
Explanation
This fault typically occurs when number of multicast mac addreses on the fabric interconnect has reached an upper threshold. It gets cleared when the numbers reaches a lower threshold
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
Cause: multicast-mac-exhausted
mibFaultName: fltNetworkLimitMulticastMac
Affected MO: sys/switch-[id]/limit-type-[type]-asic-[asicNumber]
fltNetworkLimitPvlifvlanmbr
Fault Code: F1896
Message
No. of PV LifVlanMbr count ([actualCount]) in the asic [asicNumber] corresponding to ports (eth [slotNumber]/[startPortNumber] through eth [slotNumber]/[endPortNumber]) on switch [id] has reached the upper limit ([upperLimit]). Will get cleared when the count reaches the lower limit ([lowerLimit])
Explanation
This fault typically occurs when number of PV LifVlanMbr on a particular asic in the fabric interconnect has reached an upper threshold. It gets cleared when the numbers reaches a lower threshold
Recommended Action
If you see this fault, take the following actions:
Step 1 The user needs to remove the chassis from the current asic and move to a different asic
Fault Details
Cause: pvlif-vlan-mbr-exhausted
mibFaultName: fltNetworkLimitPvlifvlanmbr
Affected MO: sys/switch-[id]/limit-type-[type]-asic-[asicNumber]
fltNetworkLimitPvsystem
Fault Code: F1897
Message
No. of PV System count ([actualCount]) on switch [id] has reached the upper limit ([upperLimit]). Will get cleared when the count reaches the lower limit ([lowerLimit])
Explanation
This fault typically occurs when number of PV System count on the fabric interconnect has reached an upper threshold. It gets cleared when the numbers reaches a lower threshold
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
Cause: pvsystem-exhausted
mibFaultName: fltNetworkLimitPvsystem
Affected MO: sys/switch-[id]/limit-type-[type]-asic-[asicNumber]
fltNetworkLimitIgmpgroup
Fault Code: F1898
Message
No. of IGMP Group count ([actualCount]) on switch [id] has reached the upper limit ([upperLimit]). Will get cleared when the count reaches the lower limit ([lowerLimit])
Explanation
This fault typically occurs when number of IGMP group count on the fabric interconnect has reached an upper threshold. It gets cleared when the numbers reaches a lower threshold.
Recommended Action
If you see this fault, take the following actions:
Fault Details
Cause: igmp-group-exhausted
mibFaultName: fltNetworkLimitIgmpgroup
Affected MO: sys/switch-[id]/limit-type-[type]-asic-[asicNumber]
fltMgmtDbStateDb-corruption-detected
Fault Code: F1899
Message
Management database corruption detected and recovered on Fabric Interconnect [id]. Number of corruption events: [corruptedCount]. Last corruption event timestamp: [lastOccurrenceTime]
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
Cause: mgmt-db-corruption
mibFaultName: fltMgmtDbStateDbCorruptionDetected
Affected MO: sys/switch-[id]/mgmt-db-state
fltMgmtDbStateHigh-db-corruption-detected
Fault Code: F1900
Message
High number of management database corruption events on Fabric Interconnect [id]. Number of corruption events: [corruptedCount]. Number of corruption events: [corruptedCount]. Last corruption event timestamp: [lastOccurrenceTime]
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
Cause: mgmt-db-corruption
mibFaultName: fltMgmtDbStateHighDbCorruptionDetected
Affected MO: sys/switch-[id]/mgmt-db-state
fltEquipmentInventoryStatusHardwareMismatch
Fault Code: F1901
Message
Adaptor unit inventory mismatchPass through adaptor unit extension inventory mismatchGraphics card inventory mismatchSecurity unit inventory mismatchStorage controller inventory mismatchCPU inventory mismatchDIMM inventory mismatch
Explanation
UCSM raises this fault under the following conditions:
Step 1 If any server hardware component is changed in a rack server without decommissioning the server.
Step 2 If any server hardware component is changed in a non-rack server and the server is not acknowledged.
Recommended Action
If you see this fault, take the following actions:
Step 1 For rack servers, decommission and recommission the server if any hardware component is changed.
Step 2 For non-rack servers, acknowledge the server if any hardware component is changed.
Step 3 If no hardware component was changed, Create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentInventoryStatusHardwareMismatch
moClass: equipment:InventoryStatus
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/adaptor-extn-[id]/inv-status
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/inv-status
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]/inv-status
Affected MO: sys/chassis-[id]/blade-[slotId]/board/graphics-card-[id]/inv-status
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]/mem-[id]/inv-status
Affected MO: sys/chassis-[id]/blade-[slotId]/board/security-unit-[id]/inv-status
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/inv-status
Affected MO: sys/chassis-[id]/blade-[slotId]/inv-status
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/adaptor-extn-[id]/inv-status
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/inv-status
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/cpu-[id]/inv-status
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/graphics-card-[id]/inv-status
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/memarray-[id]/mem-[id]/inv-status
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/security-unit-[id]/inv-status
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/inv-status
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/inv-status
Affected MO: sys/chassis-[id]/storage-[type]-[id]/inv-status
Affected MO: sys/rack-unit-[id]/adaptor-[id]/adaptor-extn-[id]/inv-status
Affected MO: sys/rack-unit-[id]/adaptor-[id]/inv-status
Affected MO: sys/rack-unit-[id]/board/cpu-[id]/inv-status
Affected MO: sys/rack-unit-[id]/board/graphics-card-[id]/inv-status
Affected MO: sys/rack-unit-[id]/board/memarray-[id]/mem-[id]/inv-status
Affected MO: sys/rack-unit-[id]/board/security-unit-[id]/inv-status
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/inv-status
Affected MO: sys/rack-unit-[id]/inv-status
fltEquipmentChassisPhysical-security
Fault Code: F1902
Message
Chassis [id] operability: [operability]Chassis [id] operability: [operability]
Explanation
NOTE: This fault is not currently implemented by UCSMThis fault is present only as a placeholder, possibly for another release,such as stand-alone rack servers.---UCSM raises this fault under the following conditions:
Step 1 One or more of the chassis lids are open.
Recommended Action
If you see this fault, take the following actions:
Step 1 Close all the chassis lids.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentChassisPhysicalSecurity
moClass: equipment:Chassis
Affected MO: sys/chassis-[id]
fltEquipmentComputeConnConfig-problem
Fault Code: F1903
Message
Second server is inserted on this Chassis when server sioc connectivity was set to: [serverSiocConnectivity]
Explanation
NOTE: This fault is not currently implemented by UCSMThis fault is present only as a placeholder, possibly for another release,such as stand-alone rack servers.---UCSM raises this fault under the following conditions:
Step 1 Second server inserted into this chassis, when Single Server Dual SIOC connectivity was selected for the chassis..
Recommended Action
If you see this fault, take the following actions:
Step 1 Correct Single Server Dual VIC configuration.
Step 2 If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
mibFaultName: fltEquipmentComputeConnConfigProblem
moClass: equipment:ComputeConn
Affected MO: sys/chassis-[id]/compute-conn
fltVnicEtherPrimaryVlanMissing
Fault Code: F1907
Message
Hard pinning target for eth vNIC [name], service profile [name] does not have the corresponding primary VLAN configured
Explanation
This fault occurs when secondary VLAN configured on a vNIC has no corresponding primary VLAN configured on the target uplink port or port channel for a hard-pinned LAN pin group.
Recommended Action
If you see this fault, take the following actions:
Step 1 Review the LAN pin group configuration.
Step 2 Correct the configuration of the port and port channels in the pin group.
Step 3 In the LAN Uplinks Manager of the Cisco UCS Manager GUI, configure primary VLANs in the target uplink port or port channel for the corresponding secodary VLAN configured in the vNIC.
Step 4 If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: missing-primary-vlan
mibFaultName: fltVnicEtherPrimaryVlanMissing
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]
fltVnicEtherNetSanGroupMisconfigured
Fault Code: F1908
Message
Network/SAN group has been misconfigured
Explanation
This fault occurs when native vlan of a vnicEtherIf and native vlan of a netGroup assigned to a vNIC are not same.
Recommended Action
If you see this fault, take the following actions:
Step 1 Change the native vlan on the vnicEtherIf or the NetGroup to be same.
Fault Details
Cause: network-san-group-misconfigured
mibFaultName: fltVnicEtherNetSanGroupMisconfigured
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]
fltComputePhysicalKmipFault
Fault Code: F1912
Message
Server [id] (service profile: [assignedToDn]) kmip fault [kmipFault]. Reason : [kmipFaultDescription].Server [chassisId]/[slotId] (service profile: [assignedToDn]) kmip fault [kmipFault]. Reason : [kmipFaultDescription].
Explanation
This fault typically occurs Cisco UCS Manager has detected some issue with the KMIP server
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. Also refer to the Cisco ACI Release Notes and the Cisco ACI Troubleshooting Guide. If you cannot resolve the issue, export an On-demand TechSupport data file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltComputePhysicalKmipFault
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalHardwareInventoryMismatch
Fault Code: F1913
Message
Server [id] hardware inventory mismatch. Decommission and recommission the server to clear the faultServer [chassisId]/[slotId] hardware inventory mismatch. Acknowledge the server to clear the fault
Explanation
UCSM raises this fault under the following conditions:
Step 1 If any server hardware component is changed in a rack server without decommissioning the server.
Step 2 If any server hardware component is changed in a non-rack server and the server is not acknowledged.
Recommended Action
If you see this fault, take the following actions:
Step 1 For rack servers, decommission and recommission the server if any hardware component is changed.
Step 2 For non-rack servers, acknowledge the server if any hardware component is changed.
Step 3 If no hardware component was changed, Create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: hardware-inventory-mismatch
mibFaultName: fltComputePhysicalHardwareInventoryMismatch
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalPciConfigMismatch
Fault Code: F1914
Message
Mismatch in PCIe configuration of the chassis adapters
Explanation
UCSM raises this fault under the following conditions:
Step 1 If the SIOC is replaced and the new SIOC is running pre 3.1.3 CMC firmware that does not support Single Server Dual SIOC connectivity for the chassis.
Recommended Action
If you see this fault, take the following actions:
Step 1 Re-trigger chassis profile association, to update the SIOC firmware and reconfigure server SIOC Connectivity
Step 2 If SIOC was not replaced, Create a show tech-support file and contact Cisco TAC.
Fault Details
Cause: pci-config-mismatch
mibFaultName: fltComputePhysicalPciConfigMismatch
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltStorageEnclosureDiskSlotEpSecond-controller-absent
Fault Code: F1915
Message
Slot [id]/[id]/[id] ownership is automatically unassigned because of unavailability of second storage controller in the server.
Explanation
This fault indicates that a disk slot ownership is automatically unassigned because there were no second controller attached to the server.
Recommended Action
If you see this fault, take the following actions:
Step 1 Add a second controller to the server (or) change the ownership in disk zoning policy
Fault Details
Cause: equipment-second-controller-absent
mibFaultName: fltStorageEnclosureDiskSlotEpSecondControllerAbsent
moClass: storage:EnclosureDiskSlotEp
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-slot-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-slot-[id]
tcaProcessorLoad
Fault Code: F33142
Message
Threshold Crossed: processor:Runtime property: load
Explanation
Recommended Action
Fault Details
mibFaultName: tcaProcessorLoad
moClass: processor:Runtime
Affected MO: sys/chassis-[id]/blade-[slotId]/cpu-rt
tcaProcessorLoadMin
Fault Code: F33144
Message
Threshold Crossed: processor:Runtime property: loadMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaProcessorLoadMin
moClass: processor:Runtime
Affected MO: sys/chassis-[id]/blade-[slotId]/cpu-rt
tcaProcessorLoadMax
Fault Code: F33145
Message
Threshold Crossed: processor:Runtime property: loadMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaProcessorLoadMax
moClass: processor:Runtime
Affected MO: sys/chassis-[id]/blade-[slotId]/cpu-rt
tcaProcessorLoadAvg
Fault Code: F33146
Message
Threshold Crossed: processor:Runtime property: loadAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaProcessorLoadAvg
moClass: processor:Runtime
Affected MO: sys/chassis-[id]/blade-[slotId]/cpu-rt
tcaFcBytesRxDelta
Fault Code: F33167
Message
Threshold Crossed: fc:Stats property: bytesRxDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcBytesRxDelta
Affected MO: fabric/san/[id]/pc-[portId]/stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/stats
tcaFcBytesRxDeltaMin
Fault Code: F33168
Message
Threshold Crossed: fc:Stats property: bytesRxDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcBytesRxDeltaMin
Affected MO: fabric/san/[id]/pc-[portId]/stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/stats
tcaFcBytesRxDeltaMax
Fault Code: F33169
Message
Threshold Crossed: fc:Stats property: bytesRxDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcBytesRxDeltaMax
Affected MO: fabric/san/[id]/pc-[portId]/stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/stats
tcaFcBytesRxDeltaAvg
Fault Code: F33170
Message
Threshold Crossed: fc:Stats property: bytesRxDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcBytesRxDeltaAvg
Affected MO: fabric/san/[id]/pc-[portId]/stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/stats
tcaFcPacketsRxDelta
Fault Code: F33177
Message
Threshold Crossed: fc:Stats property: packetsRxDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcPacketsRxDelta
Affected MO: fabric/san/[id]/pc-[portId]/stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/stats
tcaFcPacketsRxDeltaMin
Fault Code: F33178
Message
Threshold Crossed: fc:Stats property: packetsRxDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcPacketsRxDeltaMin
Affected MO: fabric/san/[id]/pc-[portId]/stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/stats
tcaFcPacketsRxDeltaMax
Fault Code: F33179
Message
Threshold Crossed: fc:Stats property: packetsRxDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcPacketsRxDeltaMax
Affected MO: fabric/san/[id]/pc-[portId]/stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/stats
tcaFcPacketsRxDeltaAvg
Fault Code: F33180
Message
Threshold Crossed: fc:Stats property: packetsRxDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcPacketsRxDeltaAvg
Affected MO: fabric/san/[id]/pc-[portId]/stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/stats
tcaFcBytesTxDelta
Fault Code: F33187
Message
Threshold Crossed: fc:Stats property: bytesTxDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcBytesTxDelta
Affected MO: fabric/san/[id]/pc-[portId]/stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/stats
tcaFcBytesTxDeltaMin
Fault Code: F33188
Message
Threshold Crossed: fc:Stats property: bytesTxDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcBytesTxDeltaMin
Affected MO: fabric/san/[id]/pc-[portId]/stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/stats
tcaFcBytesTxDeltaMax
Fault Code: F33189
Message
Threshold Crossed: fc:Stats property: bytesTxDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcBytesTxDeltaMax
Affected MO: fabric/san/[id]/pc-[portId]/stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/stats
tcaFcBytesTxDeltaAvg
Fault Code: F33190
Message
Threshold Crossed: fc:Stats property: bytesTxDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcBytesTxDeltaAvg
Affected MO: fabric/san/[id]/pc-[portId]/stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/stats
tcaFcPacketsTxDelta
Fault Code: F33197
Message
Threshold Crossed: fc:Stats property: packetsTxDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcPacketsTxDelta
Affected MO: fabric/san/[id]/pc-[portId]/stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/stats
tcaFcPacketsTxDeltaMin
Fault Code: F33198
Message
Threshold Crossed: fc:Stats property: packetsTxDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcPacketsTxDeltaMin
Affected MO: fabric/san/[id]/pc-[portId]/stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/stats
tcaFcPacketsTxDeltaMax
Fault Code: F33199
Message
Threshold Crossed: fc:Stats property: packetsTxDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcPacketsTxDeltaMax
Affected MO: fabric/san/[id]/pc-[portId]/stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/stats
tcaFcPacketsTxDeltaAvg
Fault Code: F33200
Message
Threshold Crossed: fc:Stats property: packetsTxDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcPacketsTxDeltaAvg
Affected MO: fabric/san/[id]/pc-[portId]/stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/stats
tcaFcCrcRxDelta
Fault Code: F33211
Message
Threshold Crossed: fc:ErrStats property: crcRxDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcCrcRxDelta
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaFcCrcRxDeltaMin
Fault Code: F33212
Message
Threshold Crossed: fc:ErrStats property: crcRxDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcCrcRxDeltaMin
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaFcCrcRxDeltaMax
Fault Code: F33213
Message
Threshold Crossed: fc:ErrStats property: crcRxDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcCrcRxDeltaMax
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaFcCrcRxDeltaAvg
Fault Code: F33214
Message
Threshold Crossed: fc:ErrStats property: crcRxDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcCrcRxDeltaAvg
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaFcDiscardRxDelta
Fault Code: F33221
Message
Threshold Crossed: fc:ErrStats property: discardRxDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcDiscardRxDelta
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaFcDiscardRxDeltaMin
Fault Code: F33222
Message
Threshold Crossed: fc:ErrStats property: discardRxDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcDiscardRxDeltaMin
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaFcDiscardRxDeltaMax
Fault Code: F33223
Message
Threshold Crossed: fc:ErrStats property: discardRxDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcDiscardRxDeltaMax
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaFcDiscardRxDeltaAvg
Fault Code: F33224
Message
Threshold Crossed: fc:ErrStats property: discardRxDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcDiscardRxDeltaAvg
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaFcTooLongRxDelta
Fault Code: F33231
Message
Threshold Crossed: fc:ErrStats property: tooLongRxDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcTooLongRxDelta
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaFcTooLongRxDeltaMin
Fault Code: F33232
Message
Threshold Crossed: fc:ErrStats property: tooLongRxDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcTooLongRxDeltaMin
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaFcTooLongRxDeltaMax
Fault Code: F33233
Message
Threshold Crossed: fc:ErrStats property: tooLongRxDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcTooLongRxDeltaMax
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaFcTooLongRxDeltaAvg
Fault Code: F33234
Message
Threshold Crossed: fc:ErrStats property: tooLongRxDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcTooLongRxDeltaAvg
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaFcTooShortRxDelta
Fault Code: F33241
Message
Threshold Crossed: fc:ErrStats property: tooShortRxDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcTooShortRxDelta
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaFcTooShortRxDeltaMin
Fault Code: F33242
Message
Threshold Crossed: fc:ErrStats property: tooShortRxDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcTooShortRxDeltaMin
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaFcTooShortRxDeltaMax
Fault Code: F33243
Message
Threshold Crossed: fc:ErrStats property: tooShortRxDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcTooShortRxDeltaMax
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaFcTooShortRxDeltaAvg
Fault Code: F33244
Message
Threshold Crossed: fc:ErrStats property: tooShortRxDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcTooShortRxDeltaAvg
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaFcRxDelta
Fault Code: F33251
Message
Threshold Crossed: fc:ErrStats property: rxDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcRxDelta
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaFcRxDeltaMin
Fault Code: F33252
Message
Threshold Crossed: fc:ErrStats property: rxDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcRxDeltaMin
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaFcRxDeltaMax
Fault Code: F33253
Message
Threshold Crossed: fc:ErrStats property: rxDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcRxDeltaMax
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaFcRxDeltaAvg
Fault Code: F33254
Message
Threshold Crossed: fc:ErrStats property: rxDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcRxDeltaAvg
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaFcDiscardTxDelta
Fault Code: F33261
Message
Threshold Crossed: fc:ErrStats property: discardTxDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcDiscardTxDelta
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaFcDiscardTxDeltaMin
Fault Code: F33262
Message
Threshold Crossed: fc:ErrStats property: discardTxDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcDiscardTxDeltaMin
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaFcDiscardTxDeltaMax
Fault Code: F33263
Message
Threshold Crossed: fc:ErrStats property: discardTxDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcDiscardTxDeltaMax
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaFcDiscardTxDeltaAvg
Fault Code: F33264
Message
Threshold Crossed: fc:ErrStats property: discardTxDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcDiscardTxDeltaAvg
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaFcTxDelta
Fault Code: F33271
Message
Threshold Crossed: fc:ErrStats property: txDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcTxDelta
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaFcTxDeltaMin
Fault Code: F33272
Message
Threshold Crossed: fc:ErrStats property: txDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcTxDeltaMin
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaFcTxDeltaMax
Fault Code: F33273
Message
Threshold Crossed: fc:ErrStats property: txDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcTxDeltaMax
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaFcTxDeltaAvg
Fault Code: F33274
Message
Threshold Crossed: fc:ErrStats property: txDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcTxDeltaAvg
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaFcLinkFailuresDelta
Fault Code: F33281
Message
Threshold Crossed: fc:ErrStats property: linkFailuresDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcLinkFailuresDelta
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaFcLinkFailuresDeltaMin
Fault Code: F33282
Message
Threshold Crossed: fc:ErrStats property: linkFailuresDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcLinkFailuresDeltaMin
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaFcLinkFailuresDeltaMax
Fault Code: F33283
Message
Threshold Crossed: fc:ErrStats property: linkFailuresDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcLinkFailuresDeltaMax
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaFcLinkFailuresDeltaAvg
Fault Code: F33284
Message
Threshold Crossed: fc:ErrStats property: linkFailuresDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcLinkFailuresDeltaAvg
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaFcSyncLossesDelta
Fault Code: F33291
Message
Threshold Crossed: fc:ErrStats property: syncLossesDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcSyncLossesDelta
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaFcSyncLossesDeltaMin
Fault Code: F33292
Message
Threshold Crossed: fc:ErrStats property: syncLossesDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcSyncLossesDeltaMin
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaFcSyncLossesDeltaMax
Fault Code: F33293
Message
Threshold Crossed: fc:ErrStats property: syncLossesDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcSyncLossesDeltaMax
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaFcSyncLossesDeltaAvg
Fault Code: F33294
Message
Threshold Crossed: fc:ErrStats property: syncLossesDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcSyncLossesDeltaAvg
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaFcSignalLossesDelta
Fault Code: F33301
Message
Threshold Crossed: fc:ErrStats property: signalLossesDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcSignalLossesDelta
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaFcSignalLossesDeltaMin
Fault Code: F33302
Message
Threshold Crossed: fc:ErrStats property: signalLossesDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcSignalLossesDeltaMin
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaFcSignalLossesDeltaMax
Fault Code: F33303
Message
Threshold Crossed: fc:ErrStats property: signalLossesDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcSignalLossesDeltaMax
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaFcSignalLossesDeltaAvg
Fault Code: F33304
Message
Threshold Crossed: fc:ErrStats property: signalLossesDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaFcSignalLossesDeltaAvg
Affected MO: fabric/san/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaMemoryTotal
Fault Code: F33483
Message
Threshold Crossed: memory:Runtime property: total
Explanation
Recommended Action
Fault Details
mibFaultName: tcaMemoryTotal
Affected MO: sys/chassis-[id]/blade-[slotId]/[type]-mem-rt
tcaMemoryTotalMin
Fault Code: F33485
Message
Threshold Crossed: memory:Runtime property: totalMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaMemoryTotalMin
Affected MO: sys/chassis-[id]/blade-[slotId]/[type]-mem-rt
tcaMemoryTotalMax
Fault Code: F33486
Message
Threshold Crossed: memory:Runtime property: totalMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaMemoryTotalMax
Affected MO: sys/chassis-[id]/blade-[slotId]/[type]-mem-rt
tcaMemoryTotalAvg
Fault Code: F33487
Message
Threshold Crossed: memory:Runtime property: totalAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaMemoryTotalAvg
Affected MO: sys/chassis-[id]/blade-[slotId]/[type]-mem-rt
tcaMemoryAvailable
Fault Code: F33491
Message
Threshold Crossed: memory:Runtime property: available
Explanation
Recommended Action
Fault Details
mibFaultName: tcaMemoryAvailable
Affected MO: sys/chassis-[id]/blade-[slotId]/[type]-mem-rt
tcaMemoryAvailableMin
Fault Code: F33493
Message
Threshold Crossed: memory:Runtime property: availableMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaMemoryAvailableMin
Affected MO: sys/chassis-[id]/blade-[slotId]/[type]-mem-rt
tcaMemoryAvailableMax
Fault Code: F33494
Message
Threshold Crossed: memory:Runtime property: availableMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaMemoryAvailableMax
Affected MO: sys/chassis-[id]/blade-[slotId]/[type]-mem-rt
tcaMemoryAvailableAvg
Fault Code: F33495
Message
Threshold Crossed: memory:Runtime property: availableAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaMemoryAvailableAvg
Affected MO: sys/chassis-[id]/blade-[slotId]/[type]-mem-rt
tcaMemoryCached
Fault Code: F33499
Message
Threshold Crossed: memory:Runtime property: cached
Explanation
Recommended Action
Fault Details
mibFaultName: tcaMemoryCached
Affected MO: sys/chassis-[id]/blade-[slotId]/[type]-mem-rt
tcaMemoryCachedMin
Fault Code: F33501
Message
Threshold Crossed: memory:Runtime property: cachedMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaMemoryCachedMin
Affected MO: sys/chassis-[id]/blade-[slotId]/[type]-mem-rt
tcaMemoryCachedMax
Fault Code: F33502
Message
Threshold Crossed: memory:Runtime property: cachedMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaMemoryCachedMax
Affected MO: sys/chassis-[id]/blade-[slotId]/[type]-mem-rt
tcaMemoryCachedAvg
Fault Code: F33503
Message
Threshold Crossed: memory:Runtime property: cachedAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaMemoryCachedAvg
Affected MO: sys/chassis-[id]/blade-[slotId]/[type]-mem-rt
tcaAdaptorTotalPacketsDelta
Fault Code: F33720
Message
Threshold Crossed: adaptor:EthPortStats property: totalPacketsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTotalPacketsDelta
moClass: adaptor:EthPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
tcaAdaptorTotalPacketsDeltaMin
Fault Code: F33721
Message
Threshold Crossed: adaptor:EthPortStats property: totalPacketsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTotalPacketsDeltaMin
moClass: adaptor:EthPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
tcaAdaptorTotalPacketsDeltaMax
Fault Code: F33722
Message
Threshold Crossed: adaptor:EthPortStats property: totalPacketsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTotalPacketsDeltaMax
moClass: adaptor:EthPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
tcaAdaptorTotalPacketsDeltaAvg
Fault Code: F33723
Message
Threshold Crossed: adaptor:EthPortStats property: totalPacketsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTotalPacketsDeltaAvg
moClass: adaptor:EthPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
tcaAdaptorGoodPacketsDelta
Fault Code: F33730
Message
Threshold Crossed: adaptor:EthPortStats property: goodPacketsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorGoodPacketsDelta
moClass: adaptor:EthPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
tcaAdaptorGoodPacketsDeltaMin
Fault Code: F33731
Message
Threshold Crossed: adaptor:EthPortStats property: goodPacketsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorGoodPacketsDeltaMin
moClass: adaptor:EthPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
tcaAdaptorGoodPacketsDeltaMax
Fault Code: F33732
Message
Threshold Crossed: adaptor:EthPortStats property: goodPacketsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorGoodPacketsDeltaMax
moClass: adaptor:EthPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
tcaAdaptorGoodPacketsDeltaAvg
Fault Code: F33733
Message
Threshold Crossed: adaptor:EthPortStats property: goodPacketsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorGoodPacketsDeltaAvg
moClass: adaptor:EthPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
tcaAdaptorVlanPacketsDelta
Fault Code: F33740
Message
Threshold Crossed: adaptor:EthPortStats property: vlanPacketsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorVlanPacketsDelta
moClass: adaptor:EthPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
tcaAdaptorVlanPacketsDeltaMin
Fault Code: F33741
Message
Threshold Crossed: adaptor:EthPortStats property: vlanPacketsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorVlanPacketsDeltaMin
moClass: adaptor:EthPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
tcaAdaptorVlanPacketsDeltaMax
Fault Code: F33742
Message
Threshold Crossed: adaptor:EthPortStats property: vlanPacketsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorVlanPacketsDeltaMax
moClass: adaptor:EthPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
tcaAdaptorVlanPacketsDeltaAvg
Fault Code: F33743
Message
Threshold Crossed: adaptor:EthPortStats property: vlanPacketsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorVlanPacketsDeltaAvg
moClass: adaptor:EthPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
tcaAdaptorPausePacketsDelta
Fault Code: F33750
Message
Threshold Crossed: adaptor:EthPortStats property: pausePacketsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPausePacketsDelta
moClass: adaptor:EthPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
tcaAdaptorPausePacketsDeltaMin
Fault Code: F33751
Message
Threshold Crossed: adaptor:EthPortStats property: pausePacketsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPausePacketsDeltaMin
moClass: adaptor:EthPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
tcaAdaptorPausePacketsDeltaMax
Fault Code: F33752
Message
Threshold Crossed: adaptor:EthPortStats property: pausePacketsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPausePacketsDeltaMax
moClass: adaptor:EthPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
tcaAdaptorPausePacketsDeltaAvg
Fault Code: F33753
Message
Threshold Crossed: adaptor:EthPortStats property: pausePacketsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPausePacketsDeltaAvg
moClass: adaptor:EthPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
tcaAdaptorPerPriorityPausePacketsDelta
Fault Code: F33760
Message
Threshold Crossed: adaptor:EthPortStats property: perPriorityPausePacketsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPerPriorityPausePacketsDelta
moClass: adaptor:EthPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
tcaAdaptorPerPriorityPausePacketsDeltaMin
Fault Code: F33761
Message
Threshold Crossed: adaptor:EthPortStats property: perPriorityPausePacketsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPerPriorityPausePacketsDeltaMin
moClass: adaptor:EthPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
tcaAdaptorPerPriorityPausePacketsDeltaMax
Fault Code: F33762
Message
Threshold Crossed: adaptor:EthPortStats property: perPriorityPausePacketsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPerPriorityPausePacketsDeltaMax
moClass: adaptor:EthPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
tcaAdaptorPerPriorityPausePacketsDeltaAvg
Fault Code: F33763
Message
Threshold Crossed: adaptor:EthPortStats property: perPriorityPausePacketsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPerPriorityPausePacketsDeltaAvg
moClass: adaptor:EthPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
tcaAdaptorPppPacketsDelta
Fault Code: F33770
Message
Threshold Crossed: adaptor:EthPortStats property: pppPacketsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPppPacketsDelta
moClass: adaptor:EthPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
tcaAdaptorPppPacketsDeltaMin
Fault Code: F33771
Message
Threshold Crossed: adaptor:EthPortStats property: pppPacketsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPppPacketsDeltaMin
moClass: adaptor:EthPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
tcaAdaptorPppPacketsDeltaMax
Fault Code: F33772
Message
Threshold Crossed: adaptor:EthPortStats property: pppPacketsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPppPacketsDeltaMax
moClass: adaptor:EthPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
tcaAdaptorPppPacketsDeltaAvg
Fault Code: F33773
Message
Threshold Crossed: adaptor:EthPortStats property: pppPacketsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPppPacketsDeltaAvg
moClass: adaptor:EthPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-stats-[trafficDirection]
tcaAdaptorLessThan64Delta
Fault Code: F33810
Message
Threshold Crossed: adaptor:EthPortBySizeSmallStats property: lessThan64Delta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThan64Delta
moClass: adaptor:EthPortBySizeSmallStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
tcaAdaptorLessThan64DeltaMin
Fault Code: F33811
Message
Threshold Crossed: adaptor:EthPortBySizeSmallStats property: lessThan64DeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThan64DeltaMin
moClass: adaptor:EthPortBySizeSmallStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
tcaAdaptorLessThan64DeltaMax
Fault Code: F33812
Message
Threshold Crossed: adaptor:EthPortBySizeSmallStats property: lessThan64DeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThan64DeltaMax
moClass: adaptor:EthPortBySizeSmallStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
tcaAdaptorLessThan64DeltaAvg
Fault Code: F33813
Message
Threshold Crossed: adaptor:EthPortBySizeSmallStats property: lessThan64DeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThan64DeltaAvg
moClass: adaptor:EthPortBySizeSmallStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
tcaAdaptorEquals64Delta
Fault Code: F33820
Message
Threshold Crossed: adaptor:EthPortBySizeSmallStats property: equals64Delta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorEquals64Delta
moClass: adaptor:EthPortBySizeSmallStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
tcaAdaptorEquals64DeltaMin
Fault Code: F33821
Message
Threshold Crossed: adaptor:EthPortBySizeSmallStats property: equals64DeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorEquals64DeltaMin
moClass: adaptor:EthPortBySizeSmallStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
tcaAdaptorEquals64DeltaMax
Fault Code: F33822
Message
Threshold Crossed: adaptor:EthPortBySizeSmallStats property: equals64DeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorEquals64DeltaMax
moClass: adaptor:EthPortBySizeSmallStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
tcaAdaptorEquals64DeltaAvg
Fault Code: F33823
Message
Threshold Crossed: adaptor:EthPortBySizeSmallStats property: equals64DeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorEquals64DeltaAvg
moClass: adaptor:EthPortBySizeSmallStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
tcaAdaptorLessThan128Delta
Fault Code: F33830
Message
Threshold Crossed: adaptor:EthPortBySizeSmallStats property: lessThan128Delta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThan128Delta
moClass: adaptor:EthPortBySizeSmallStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
tcaAdaptorLessThan128DeltaMin
Fault Code: F33831
Message
Threshold Crossed: adaptor:EthPortBySizeSmallStats property: lessThan128DeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThan128DeltaMin
moClass: adaptor:EthPortBySizeSmallStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
tcaAdaptorLessThan128DeltaMax
Fault Code: F33832
Message
Threshold Crossed: adaptor:EthPortBySizeSmallStats property: lessThan128DeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThan128DeltaMax
moClass: adaptor:EthPortBySizeSmallStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
tcaAdaptorLessThan128DeltaAvg
Fault Code: F33833
Message
Threshold Crossed: adaptor:EthPortBySizeSmallStats property: lessThan128DeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThan128DeltaAvg
moClass: adaptor:EthPortBySizeSmallStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
tcaAdaptorLessThan256Delta
Fault Code: F33840
Message
Threshold Crossed: adaptor:EthPortBySizeSmallStats property: lessThan256Delta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThan256Delta
moClass: adaptor:EthPortBySizeSmallStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
tcaAdaptorLessThan256DeltaMin
Fault Code: F33841
Message
Threshold Crossed: adaptor:EthPortBySizeSmallStats property: lessThan256DeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThan256DeltaMin
moClass: adaptor:EthPortBySizeSmallStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
tcaAdaptorLessThan256DeltaMax
Fault Code: F33842
Message
Threshold Crossed: adaptor:EthPortBySizeSmallStats property: lessThan256DeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThan256DeltaMax
moClass: adaptor:EthPortBySizeSmallStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
tcaAdaptorLessThan256DeltaAvg
Fault Code: F33843
Message
Threshold Crossed: adaptor:EthPortBySizeSmallStats property: lessThan256DeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThan256DeltaAvg
moClass: adaptor:EthPortBySizeSmallStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
tcaAdaptorLessThan512Delta
Fault Code: F33850
Message
Threshold Crossed: adaptor:EthPortBySizeSmallStats property: lessThan512Delta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThan512Delta
moClass: adaptor:EthPortBySizeSmallStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
tcaAdaptorLessThan512DeltaMin
Fault Code: F33851
Message
Threshold Crossed: adaptor:EthPortBySizeSmallStats property: lessThan512DeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThan512DeltaMin
moClass: adaptor:EthPortBySizeSmallStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
tcaAdaptorLessThan512DeltaMax
Fault Code: F33852
Message
Threshold Crossed: adaptor:EthPortBySizeSmallStats property: lessThan512DeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThan512DeltaMax
moClass: adaptor:EthPortBySizeSmallStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
tcaAdaptorLessThan512DeltaAvg
Fault Code: F33853
Message
Threshold Crossed: adaptor:EthPortBySizeSmallStats property: lessThan512DeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThan512DeltaAvg
moClass: adaptor:EthPortBySizeSmallStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
tcaAdaptorLessThan1024Delta
Fault Code: F33860
Message
Threshold Crossed: adaptor:EthPortBySizeSmallStats property: lessThan1024Delta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThan1024Delta
moClass: adaptor:EthPortBySizeSmallStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
tcaAdaptorLessThan1024DeltaMin
Fault Code: F33861
Message
Threshold Crossed: adaptor:EthPortBySizeSmallStats property: lessThan1024DeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThan1024DeltaMin
moClass: adaptor:EthPortBySizeSmallStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
tcaAdaptorLessThan1024DeltaMax
Fault Code: F33862
Message
Threshold Crossed: adaptor:EthPortBySizeSmallStats property: lessThan1024DeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThan1024DeltaMax
moClass: adaptor:EthPortBySizeSmallStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
tcaAdaptorLessThan1024DeltaAvg
Fault Code: F33863
Message
Threshold Crossed: adaptor:EthPortBySizeSmallStats property: lessThan1024DeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThan1024DeltaAvg
moClass: adaptor:EthPortBySizeSmallStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-small-stats-[trafficDirection]
tcaAdaptorLessThanOrEqualTo1518Delta
Fault Code: F33875
Message
Threshold Crossed: adaptor:EthPortBySizeLargeStats property: lessThanOrEqualTo1518Delta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThanOrEqualTo1518Delta
moClass: adaptor:EthPortBySizeLargeStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
tcaAdaptorLessThanOrEqualTo1518DeltaMin
Fault Code: F33876
Message
Threshold Crossed: adaptor:EthPortBySizeLargeStats property: lessThanOrEqualTo1518DeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThanOrEqualTo1518DeltaMin
moClass: adaptor:EthPortBySizeLargeStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
tcaAdaptorLessThanOrEqualTo1518DeltaMax
Fault Code: F33877
Message
Threshold Crossed: adaptor:EthPortBySizeLargeStats property: lessThanOrEqualTo1518DeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThanOrEqualTo1518DeltaMax
moClass: adaptor:EthPortBySizeLargeStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
tcaAdaptorLessThanOrEqualTo1518DeltaAvg
Fault Code: F33878
Message
Threshold Crossed: adaptor:EthPortBySizeLargeStats property: lessThanOrEqualTo1518DeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThanOrEqualTo1518DeltaAvg
moClass: adaptor:EthPortBySizeLargeStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
tcaAdaptorLessThan2048Delta
Fault Code: F33885
Message
Threshold Crossed: adaptor:EthPortBySizeLargeStats property: lessThan2048Delta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThan2048Delta
moClass: adaptor:EthPortBySizeLargeStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
tcaAdaptorLessThan2048DeltaMin
Fault Code: F33886
Message
Threshold Crossed: adaptor:EthPortBySizeLargeStats property: lessThan2048DeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThan2048DeltaMin
moClass: adaptor:EthPortBySizeLargeStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
tcaAdaptorLessThan2048DeltaMax
Fault Code: F33887
Message
Threshold Crossed: adaptor:EthPortBySizeLargeStats property: lessThan2048DeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThan2048DeltaMax
moClass: adaptor:EthPortBySizeLargeStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
tcaAdaptorLessThan2048DeltaAvg
Fault Code: F33888
Message
Threshold Crossed: adaptor:EthPortBySizeLargeStats property: lessThan2048DeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThan2048DeltaAvg
moClass: adaptor:EthPortBySizeLargeStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
tcaAdaptorLessThan4096Delta
Fault Code: F33895
Message
Threshold Crossed: adaptor:EthPortBySizeLargeStats property: lessThan4096Delta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThan4096Delta
moClass: adaptor:EthPortBySizeLargeStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
tcaAdaptorLessThan4096DeltaMin
Fault Code: F33896
Message
Threshold Crossed: adaptor:EthPortBySizeLargeStats property: lessThan4096DeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThan4096DeltaMin
moClass: adaptor:EthPortBySizeLargeStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
tcaAdaptorLessThan4096DeltaMax
Fault Code: F33897
Message
Threshold Crossed: adaptor:EthPortBySizeLargeStats property: lessThan4096DeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThan4096DeltaMax
moClass: adaptor:EthPortBySizeLargeStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
tcaAdaptorLessThan4096DeltaAvg
Fault Code: F33898
Message
Threshold Crossed: adaptor:EthPortBySizeLargeStats property: lessThan4096DeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThan4096DeltaAvg
moClass: adaptor:EthPortBySizeLargeStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
tcaAdaptorLessThan8192Delta
Fault Code: F33905
Message
Threshold Crossed: adaptor:EthPortBySizeLargeStats property: lessThan8192Delta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThan8192Delta
moClass: adaptor:EthPortBySizeLargeStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
tcaAdaptorLessThan8192DeltaMin
Fault Code: F33906
Message
Threshold Crossed: adaptor:EthPortBySizeLargeStats property: lessThan8192DeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThan8192DeltaMin
moClass: adaptor:EthPortBySizeLargeStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
tcaAdaptorLessThan8192DeltaMax
Fault Code: F33907
Message
Threshold Crossed: adaptor:EthPortBySizeLargeStats property: lessThan8192DeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThan8192DeltaMax
moClass: adaptor:EthPortBySizeLargeStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
tcaAdaptorLessThan8192DeltaAvg
Fault Code: F33908
Message
Threshold Crossed: adaptor:EthPortBySizeLargeStats property: lessThan8192DeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThan8192DeltaAvg
moClass: adaptor:EthPortBySizeLargeStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
tcaAdaptorLessThan9216Delta
Fault Code: F33915
Message
Threshold Crossed: adaptor:EthPortBySizeLargeStats property: lessThan9216Delta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThan9216Delta
moClass: adaptor:EthPortBySizeLargeStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
tcaAdaptorLessThan9216DeltaMin
Fault Code: F33916
Message
Threshold Crossed: adaptor:EthPortBySizeLargeStats property: lessThan9216DeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThan9216DeltaMin
moClass: adaptor:EthPortBySizeLargeStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
tcaAdaptorLessThan9216DeltaMax
Fault Code: F33917
Message
Threshold Crossed: adaptor:EthPortBySizeLargeStats property: lessThan9216DeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThan9216DeltaMax
moClass: adaptor:EthPortBySizeLargeStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
tcaAdaptorLessThan9216DeltaAvg
Fault Code: F33918
Message
Threshold Crossed: adaptor:EthPortBySizeLargeStats property: lessThan9216DeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLessThan9216DeltaAvg
moClass: adaptor:EthPortBySizeLargeStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
tcaAdaptorGreaterThanOrEqualTo9216Delta
Fault Code: F33925
Message
Threshold Crossed: adaptor:EthPortBySizeLargeStats property: greaterThanOrEqualTo9216Delta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorGreaterThanOrEqualTo9216Delta
moClass: adaptor:EthPortBySizeLargeStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
tcaAdaptorGreaterThanOrEqualTo9216DeltaMin
Fault Code: F33926
Message
Threshold Crossed: adaptor:EthPortBySizeLargeStats property: greaterThanOrEqualTo9216DeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorGreaterThanOrEqualTo9216DeltaMin
moClass: adaptor:EthPortBySizeLargeStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
tcaAdaptorGreaterThanOrEqualTo9216DeltaMax
Fault Code: F33927
Message
Threshold Crossed: adaptor:EthPortBySizeLargeStats property: greaterThanOrEqualTo9216DeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorGreaterThanOrEqualTo9216DeltaMax
moClass: adaptor:EthPortBySizeLargeStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
tcaAdaptorGreaterThanOrEqualTo9216DeltaAvg
Fault Code: F33928
Message
Threshold Crossed: adaptor:EthPortBySizeLargeStats property: greaterThanOrEqualTo9216DeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorGreaterThanOrEqualTo9216DeltaAvg
moClass: adaptor:EthPortBySizeLargeStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
tcaAdaptorOversizedPacketsDelta
Fault Code: F33940
Message
Threshold Crossed: adaptor:EthPortOutsizedStats property: oversizedPacketsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorOversizedPacketsDelta
moClass: adaptor:EthPortOutsizedStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
tcaAdaptorOversizedPacketsDeltaMin
Fault Code: F33941
Message
Threshold Crossed: adaptor:EthPortOutsizedStats property: oversizedPacketsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorOversizedPacketsDeltaMin
moClass: adaptor:EthPortOutsizedStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
tcaAdaptorOversizedPacketsDeltaMax
Fault Code: F33942
Message
Threshold Crossed: adaptor:EthPortOutsizedStats property: oversizedPacketsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorOversizedPacketsDeltaMax
moClass: adaptor:EthPortOutsizedStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
tcaAdaptorOversizedPacketsDeltaAvg
Fault Code: F33943
Message
Threshold Crossed: adaptor:EthPortOutsizedStats property: oversizedPacketsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorOversizedPacketsDeltaAvg
moClass: adaptor:EthPortOutsizedStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
tcaAdaptorOversizedGoodCrcPacketsDelta
Fault Code: F33950
Message
Threshold Crossed: adaptor:EthPortOutsizedStats property: oversizedGoodCrcPacketsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorOversizedGoodCrcPacketsDelta
moClass: adaptor:EthPortOutsizedStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
tcaAdaptorOversizedGoodCrcPacketsDeltaMin
Fault Code: F33951
Message
Threshold Crossed: adaptor:EthPortOutsizedStats property: oversizedGoodCrcPacketsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorOversizedGoodCrcPacketsDeltaMin
moClass: adaptor:EthPortOutsizedStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
tcaAdaptorOversizedGoodCrcPacketsDeltaMax
Fault Code: F33952
Message
Threshold Crossed: adaptor:EthPortOutsizedStats property: oversizedGoodCrcPacketsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorOversizedGoodCrcPacketsDeltaMax
moClass: adaptor:EthPortOutsizedStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
tcaAdaptorOversizedGoodCrcPacketsDeltaAvg
Fault Code: F33953
Message
Threshold Crossed: adaptor:EthPortOutsizedStats property: oversizedGoodCrcPacketsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorOversizedGoodCrcPacketsDeltaAvg
moClass: adaptor:EthPortOutsizedStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
tcaAdaptorOversizedBadCrcPacketsDelta
Fault Code: F33960
Message
Threshold Crossed: adaptor:EthPortOutsizedStats property: oversizedBadCrcPacketsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorOversizedBadCrcPacketsDelta
moClass: adaptor:EthPortOutsizedStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
tcaAdaptorOversizedBadCrcPacketsDeltaMin
Fault Code: F33961
Message
Threshold Crossed: adaptor:EthPortOutsizedStats property: oversizedBadCrcPacketsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorOversizedBadCrcPacketsDeltaMin
moClass: adaptor:EthPortOutsizedStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
tcaAdaptorOversizedBadCrcPacketsDeltaMax
Fault Code: F33962
Message
Threshold Crossed: adaptor:EthPortOutsizedStats property: oversizedBadCrcPacketsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorOversizedBadCrcPacketsDeltaMax
moClass: adaptor:EthPortOutsizedStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
tcaAdaptorOversizedBadCrcPacketsDeltaAvg
Fault Code: F33963
Message
Threshold Crossed: adaptor:EthPortOutsizedStats property: oversizedBadCrcPacketsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorOversizedBadCrcPacketsDeltaAvg
moClass: adaptor:EthPortOutsizedStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
tcaAdaptorUndersizedGoodCrcPacketsDelta
Fault Code: F33970
Message
Threshold Crossed: adaptor:EthPortOutsizedStats property: undersizedGoodCrcPacketsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorUndersizedGoodCrcPacketsDelta
moClass: adaptor:EthPortOutsizedStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
tcaAdaptorUndersizedGoodCrcPacketsDeltaMin
Fault Code: F33971
Message
Threshold Crossed: adaptor:EthPortOutsizedStats property: undersizedGoodCrcPacketsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorUndersizedGoodCrcPacketsDeltaMin
moClass: adaptor:EthPortOutsizedStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
tcaAdaptorUndersizedGoodCrcPacketsDeltaMax
Fault Code: F33972
Message
Threshold Crossed: adaptor:EthPortOutsizedStats property: undersizedGoodCrcPacketsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorUndersizedGoodCrcPacketsDeltaMax
moClass: adaptor:EthPortOutsizedStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
tcaAdaptorUndersizedGoodCrcPacketsDeltaAvg
Fault Code: F33973
Message
Threshold Crossed: adaptor:EthPortOutsizedStats property: undersizedGoodCrcPacketsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorUndersizedGoodCrcPacketsDeltaAvg
moClass: adaptor:EthPortOutsizedStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
tcaAdaptorUndersizedBadCrcPacketsDelta
Fault Code: F33980
Message
Threshold Crossed: adaptor:EthPortOutsizedStats property: undersizedBadCrcPacketsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorUndersizedBadCrcPacketsDelta
moClass: adaptor:EthPortOutsizedStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
tcaAdaptorUndersizedBadCrcPacketsDeltaMin
Fault Code: F33981
Message
Threshold Crossed: adaptor:EthPortOutsizedStats property: undersizedBadCrcPacketsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorUndersizedBadCrcPacketsDeltaMin
moClass: adaptor:EthPortOutsizedStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
tcaAdaptorUndersizedBadCrcPacketsDeltaMax
Fault Code: F33982
Message
Threshold Crossed: adaptor:EthPortOutsizedStats property: undersizedBadCrcPacketsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorUndersizedBadCrcPacketsDeltaMax
moClass: adaptor:EthPortOutsizedStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
tcaAdaptorUndersizedBadCrcPacketsDeltaAvg
Fault Code: F33983
Message
Threshold Crossed: adaptor:EthPortOutsizedStats property: undersizedBadCrcPacketsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorUndersizedBadCrcPacketsDeltaAvg
moClass: adaptor:EthPortOutsizedStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-outsized-stats-[trafficDirection]
tcaAdaptorUnicastPacketsDelta
Fault Code: F33995
Message
Threshold Crossed: adaptor:EthPortMcastStats property: unicastPacketsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorUnicastPacketsDelta
moClass: adaptor:EthPortMcastStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-mcast-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-mcast-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-mcast-stats-[trafficDirection]
tcaAdaptorUnicastPacketsDeltaMin
Fault Code: F33996
Message
Threshold Crossed: adaptor:EthPortMcastStats property: unicastPacketsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorUnicastPacketsDeltaMin
moClass: adaptor:EthPortMcastStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-mcast-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-mcast-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-mcast-stats-[trafficDirection]
tcaAdaptorUnicastPacketsDeltaMax
Fault Code: F33997
Message
Threshold Crossed: adaptor:EthPortMcastStats property: unicastPacketsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorUnicastPacketsDeltaMax
moClass: adaptor:EthPortMcastStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-mcast-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-mcast-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-mcast-stats-[trafficDirection]
tcaAdaptorUnicastPacketsDeltaAvg
Fault Code: F33998
Message
Threshold Crossed: adaptor:EthPortMcastStats property: unicastPacketsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorUnicastPacketsDeltaAvg
moClass: adaptor:EthPortMcastStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-mcast-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-mcast-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-mcast-stats-[trafficDirection]
tcaAdaptorMulticastPacketsDelta
Fault Code: F34005
Message
Threshold Crossed: adaptor:EthPortMcastStats property: multicastPacketsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorMulticastPacketsDelta
moClass: adaptor:EthPortMcastStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-mcast-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-mcast-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-mcast-stats-[trafficDirection]
tcaAdaptorMulticastPacketsDeltaMin
Fault Code: F34006
Message
Threshold Crossed: adaptor:EthPortMcastStats property: multicastPacketsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorMulticastPacketsDeltaMin
moClass: adaptor:EthPortMcastStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-mcast-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-mcast-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-mcast-stats-[trafficDirection]
tcaAdaptorMulticastPacketsDeltaMax
Fault Code: F34007
Message
Threshold Crossed: adaptor:EthPortMcastStats property: multicastPacketsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorMulticastPacketsDeltaMax
moClass: adaptor:EthPortMcastStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-mcast-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-mcast-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-mcast-stats-[trafficDirection]
tcaAdaptorMulticastPacketsDeltaAvg
Fault Code: F34008
Message
Threshold Crossed: adaptor:EthPortMcastStats property: multicastPacketsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorMulticastPacketsDeltaAvg
moClass: adaptor:EthPortMcastStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-mcast-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-mcast-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-mcast-stats-[trafficDirection]
tcaAdaptorBroadcastPacketsDelta
Fault Code: F34015
Message
Threshold Crossed: adaptor:EthPortMcastStats property: broadcastPacketsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorBroadcastPacketsDelta
moClass: adaptor:EthPortMcastStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-mcast-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-mcast-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-mcast-stats-[trafficDirection]
tcaAdaptorBroadcastPacketsDeltaMin
Fault Code: F34016
Message
Threshold Crossed: adaptor:EthPortMcastStats property: broadcastPacketsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorBroadcastPacketsDeltaMin
moClass: adaptor:EthPortMcastStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-mcast-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-mcast-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-mcast-stats-[trafficDirection]
tcaAdaptorBroadcastPacketsDeltaMax
Fault Code: F34017
Message
Threshold Crossed: adaptor:EthPortMcastStats property: broadcastPacketsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorBroadcastPacketsDeltaMax
moClass: adaptor:EthPortMcastStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-mcast-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-mcast-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-mcast-stats-[trafficDirection]
tcaAdaptorBroadcastPacketsDeltaAvg
Fault Code: F34018
Message
Threshold Crossed: adaptor:EthPortMcastStats property: broadcastPacketsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorBroadcastPacketsDeltaAvg
moClass: adaptor:EthPortMcastStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-mcast-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-mcast-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-mcast-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-mcast-stats-[trafficDirection]
tcaAdaptorMacDiscardedPacketsDelta
Fault Code: F34030
Message
Threshold Crossed: adaptor:EthPortErrStats property: macDiscardedPacketsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorMacDiscardedPacketsDelta
moClass: adaptor:EthPortErrStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-err-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-err-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-err-stats-[trafficDirection]
tcaAdaptorMacDiscardedPacketsDeltaMin
Fault Code: F34031
Message
Threshold Crossed: adaptor:EthPortErrStats property: macDiscardedPacketsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorMacDiscardedPacketsDeltaMin
moClass: adaptor:EthPortErrStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-err-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-err-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-err-stats-[trafficDirection]
tcaAdaptorMacDiscardedPacketsDeltaMax
Fault Code: F34032
Message
Threshold Crossed: adaptor:EthPortErrStats property: macDiscardedPacketsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorMacDiscardedPacketsDeltaMax
moClass: adaptor:EthPortErrStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-err-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-err-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-err-stats-[trafficDirection]
tcaAdaptorMacDiscardedPacketsDeltaAvg
Fault Code: F34033
Message
Threshold Crossed: adaptor:EthPortErrStats property: macDiscardedPacketsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorMacDiscardedPacketsDeltaAvg
moClass: adaptor:EthPortErrStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-err-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-err-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-err-stats-[trafficDirection]
tcaAdaptorBadCrcPacketsDelta
Fault Code: F34040
Message
Threshold Crossed: adaptor:EthPortErrStats property: badCrcPacketsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorBadCrcPacketsDelta
moClass: adaptor:EthPortErrStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-err-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-err-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-err-stats-[trafficDirection]
tcaAdaptorBadCrcPacketsDeltaMin
Fault Code: F34041
Message
Threshold Crossed: adaptor:EthPortErrStats property: badCrcPacketsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorBadCrcPacketsDeltaMin
moClass: adaptor:EthPortErrStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-err-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-err-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-err-stats-[trafficDirection]
tcaAdaptorBadCrcPacketsDeltaMax
Fault Code: F34042
Message
Threshold Crossed: adaptor:EthPortErrStats property: badCrcPacketsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorBadCrcPacketsDeltaMax
moClass: adaptor:EthPortErrStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-err-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-err-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-err-stats-[trafficDirection]
tcaAdaptorBadCrcPacketsDeltaAvg
Fault Code: F34043
Message
Threshold Crossed: adaptor:EthPortErrStats property: badCrcPacketsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorBadCrcPacketsDeltaAvg
moClass: adaptor:EthPortErrStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-err-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-err-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-err-stats-[trafficDirection]
tcaAdaptorBadLengthPacketsDelta
Fault Code: F34050
Message
Threshold Crossed: adaptor:EthPortErrStats property: badLengthPacketsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorBadLengthPacketsDelta
moClass: adaptor:EthPortErrStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-err-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-err-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-err-stats-[trafficDirection]
tcaAdaptorBadLengthPacketsDeltaMin
Fault Code: F34051
Message
Threshold Crossed: adaptor:EthPortErrStats property: badLengthPacketsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorBadLengthPacketsDeltaMin
moClass: adaptor:EthPortErrStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-err-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-err-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-err-stats-[trafficDirection]
tcaAdaptorBadLengthPacketsDeltaMax
Fault Code: F34052
Message
Threshold Crossed: adaptor:EthPortErrStats property: badLengthPacketsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorBadLengthPacketsDeltaMax
moClass: adaptor:EthPortErrStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-err-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-err-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-err-stats-[trafficDirection]
tcaAdaptorBadLengthPacketsDeltaAvg
Fault Code: F34053
Message
Threshold Crossed: adaptor:EthPortErrStats property: badLengthPacketsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorBadLengthPacketsDeltaAvg
moClass: adaptor:EthPortErrStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-err-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-err-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-err-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-err-stats-[trafficDirection]
tcaAdaptorRxFramesDelta
Fault Code: F34064
Message
Threshold Crossed: adaptor:FcPortStats property: rxFramesDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxFramesDelta
moClass: adaptor:FcPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/fc-port-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/fc-port-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/fc-port-stats
tcaAdaptorRxFramesDeltaMin
Fault Code: F34065
Message
Threshold Crossed: adaptor:FcPortStats property: rxFramesDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxFramesDeltaMin
moClass: adaptor:FcPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/fc-port-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/fc-port-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/fc-port-stats
tcaAdaptorRxFramesDeltaMax
Fault Code: F34066
Message
Threshold Crossed: adaptor:FcPortStats property: rxFramesDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxFramesDeltaMax
moClass: adaptor:FcPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/fc-port-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/fc-port-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/fc-port-stats
tcaAdaptorRxFramesDeltaAvg
Fault Code: F34067
Message
Threshold Crossed: adaptor:FcPortStats property: rxFramesDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxFramesDeltaAvg
moClass: adaptor:FcPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/fc-port-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/fc-port-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/fc-port-stats
tcaAdaptorTxFramesDelta
Fault Code: F34074
Message
Threshold Crossed: adaptor:FcPortStats property: txFramesDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxFramesDelta
moClass: adaptor:FcPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/fc-port-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/fc-port-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/fc-port-stats
tcaAdaptorTxFramesDeltaMin
Fault Code: F34075
Message
Threshold Crossed: adaptor:FcPortStats property: txFramesDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxFramesDeltaMin
moClass: adaptor:FcPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/fc-port-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/fc-port-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/fc-port-stats
tcaAdaptorTxFramesDeltaMax
Fault Code: F34076
Message
Threshold Crossed: adaptor:FcPortStats property: txFramesDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxFramesDeltaMax
moClass: adaptor:FcPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/fc-port-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/fc-port-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/fc-port-stats
tcaAdaptorTxFramesDeltaAvg
Fault Code: F34077
Message
Threshold Crossed: adaptor:FcPortStats property: txFramesDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxFramesDeltaAvg
moClass: adaptor:FcPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/fc-port-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/fc-port-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/fc-port-stats
tcaAdaptorRxBadFramesDelta
Fault Code: F34084
Message
Threshold Crossed: adaptor:FcPortStats property: rxBadFramesDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxBadFramesDelta
moClass: adaptor:FcPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/fc-port-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/fc-port-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/fc-port-stats
tcaAdaptorRxBadFramesDeltaMin
Fault Code: F34085
Message
Threshold Crossed: adaptor:FcPortStats property: rxBadFramesDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxBadFramesDeltaMin
moClass: adaptor:FcPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/fc-port-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/fc-port-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/fc-port-stats
tcaAdaptorRxBadFramesDeltaMax
Fault Code: F34086
Message
Threshold Crossed: adaptor:FcPortStats property: rxBadFramesDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxBadFramesDeltaMax
moClass: adaptor:FcPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/fc-port-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/fc-port-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/fc-port-stats
tcaAdaptorRxBadFramesDeltaAvg
Fault Code: F34087
Message
Threshold Crossed: adaptor:FcPortStats property: rxBadFramesDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxBadFramesDeltaAvg
moClass: adaptor:FcPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/fc-port-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/fc-port-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/fc-port-stats
tcaAdaptorTxBadFramesDelta
Fault Code: F34094
Message
Threshold Crossed: adaptor:FcPortStats property: txBadFramesDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxBadFramesDelta
moClass: adaptor:FcPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/fc-port-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/fc-port-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/fc-port-stats
tcaAdaptorTxBadFramesDeltaMin
Fault Code: F34095
Message
Threshold Crossed: adaptor:FcPortStats property: txBadFramesDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxBadFramesDeltaMin
moClass: adaptor:FcPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/fc-port-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/fc-port-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/fc-port-stats
tcaAdaptorTxBadFramesDeltaMax
Fault Code: F34096
Message
Threshold Crossed: adaptor:FcPortStats property: txBadFramesDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxBadFramesDeltaMax
moClass: adaptor:FcPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/fc-port-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/fc-port-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/fc-port-stats
tcaAdaptorTxBadFramesDeltaAvg
Fault Code: F34097
Message
Threshold Crossed: adaptor:FcPortStats property: txBadFramesDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxBadFramesDeltaAvg
moClass: adaptor:FcPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-port-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/fc-port-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/fc-port-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/fc-port-stats
tcaAdaptorPacketsTxDelta
Fault Code: F34108
Message
Threshold Crossed: adaptor:VnicStats property: packetsTxDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPacketsTxDelta
moClass: adaptor:VnicStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/vnic-stats
tcaAdaptorPacketsTxDeltaMin
Fault Code: F34109
Message
Threshold Crossed: adaptor:VnicStats property: packetsTxDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPacketsTxDeltaMin
moClass: adaptor:VnicStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/vnic-stats
tcaAdaptorPacketsTxDeltaMax
Fault Code: F34110
Message
Threshold Crossed: adaptor:VnicStats property: packetsTxDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPacketsTxDeltaMax
moClass: adaptor:VnicStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/vnic-stats
tcaAdaptorPacketsTxDeltaAvg
Fault Code: F34111
Message
Threshold Crossed: adaptor:VnicStats property: packetsTxDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPacketsTxDeltaAvg
moClass: adaptor:VnicStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/vnic-stats
tcaAdaptorPacketsRxDelta
Fault Code: F34118
Message
Threshold Crossed: adaptor:VnicStats property: packetsRxDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPacketsRxDelta
moClass: adaptor:VnicStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/vnic-stats
tcaAdaptorPacketsRxDeltaMin
Fault Code: F34119
Message
Threshold Crossed: adaptor:VnicStats property: packetsRxDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPacketsRxDeltaMin
moClass: adaptor:VnicStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/vnic-stats
tcaAdaptorPacketsRxDeltaMax
Fault Code: F34120
Message
Threshold Crossed: adaptor:VnicStats property: packetsRxDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPacketsRxDeltaMax
moClass: adaptor:VnicStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/vnic-stats
tcaAdaptorPacketsRxDeltaAvg
Fault Code: F34121
Message
Threshold Crossed: adaptor:VnicStats property: packetsRxDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPacketsRxDeltaAvg
moClass: adaptor:VnicStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/vnic-stats
tcaAdaptorBytesTxDelta
Fault Code: F34128
Message
Threshold Crossed: adaptor:VnicStats property: bytesTxDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorBytesTxDelta
moClass: adaptor:VnicStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/vnic-stats
tcaAdaptorBytesTxDeltaMin
Fault Code: F34129
Message
Threshold Crossed: adaptor:VnicStats property: bytesTxDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorBytesTxDeltaMin
moClass: adaptor:VnicStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/vnic-stats
tcaAdaptorBytesTxDeltaMax
Fault Code: F34130
Message
Threshold Crossed: adaptor:VnicStats property: bytesTxDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorBytesTxDeltaMax
moClass: adaptor:VnicStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/vnic-stats
tcaAdaptorBytesTxDeltaAvg
Fault Code: F34131
Message
Threshold Crossed: adaptor:VnicStats property: bytesTxDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorBytesTxDeltaAvg
moClass: adaptor:VnicStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/vnic-stats
tcaAdaptorBytesRxDelta
Fault Code: F34138
Message
Threshold Crossed: adaptor:VnicStats property: bytesRxDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorBytesRxDelta
moClass: adaptor:VnicStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/vnic-stats
tcaAdaptorBytesRxDeltaMin
Fault Code: F34139
Message
Threshold Crossed: adaptor:VnicStats property: bytesRxDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorBytesRxDeltaMin
moClass: adaptor:VnicStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/vnic-stats
tcaAdaptorBytesRxDeltaMax
Fault Code: F34140
Message
Threshold Crossed: adaptor:VnicStats property: bytesRxDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorBytesRxDeltaMax
moClass: adaptor:VnicStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/vnic-stats
tcaAdaptorBytesRxDeltaAvg
Fault Code: F34141
Message
Threshold Crossed: adaptor:VnicStats property: bytesRxDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorBytesRxDeltaAvg
moClass: adaptor:VnicStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/vnic-stats
tcaAdaptorErrorsTxDelta
Fault Code: F34148
Message
Threshold Crossed: adaptor:VnicStats property: errorsTxDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorErrorsTxDelta
moClass: adaptor:VnicStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/vnic-stats
tcaAdaptorErrorsTxDeltaMin
Fault Code: F34149
Message
Threshold Crossed: adaptor:VnicStats property: errorsTxDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorErrorsTxDeltaMin
moClass: adaptor:VnicStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/vnic-stats
tcaAdaptorErrorsTxDeltaMax
Fault Code: F34150
Message
Threshold Crossed: adaptor:VnicStats property: errorsTxDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorErrorsTxDeltaMax
moClass: adaptor:VnicStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/vnic-stats
tcaAdaptorErrorsTxDeltaAvg
Fault Code: F34151
Message
Threshold Crossed: adaptor:VnicStats property: errorsTxDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorErrorsTxDeltaAvg
moClass: adaptor:VnicStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/vnic-stats
tcaAdaptorErrorsRxDelta
Fault Code: F34158
Message
Threshold Crossed: adaptor:VnicStats property: errorsRxDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorErrorsRxDelta
moClass: adaptor:VnicStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/vnic-stats
tcaAdaptorErrorsRxDeltaMin
Fault Code: F34159
Message
Threshold Crossed: adaptor:VnicStats property: errorsRxDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorErrorsRxDeltaMin
moClass: adaptor:VnicStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/vnic-stats
tcaAdaptorErrorsRxDeltaMax
Fault Code: F34160
Message
Threshold Crossed: adaptor:VnicStats property: errorsRxDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorErrorsRxDeltaMax
moClass: adaptor:VnicStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/vnic-stats
tcaAdaptorErrorsRxDeltaAvg
Fault Code: F34161
Message
Threshold Crossed: adaptor:VnicStats property: errorsRxDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorErrorsRxDeltaAvg
moClass: adaptor:VnicStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/vnic-stats
tcaAdaptorDroppedTxDelta
Fault Code: F34168
Message
Threshold Crossed: adaptor:VnicStats property: droppedTxDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDroppedTxDelta
moClass: adaptor:VnicStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/vnic-stats
tcaAdaptorDroppedTxDeltaMin
Fault Code: F34169
Message
Threshold Crossed: adaptor:VnicStats property: droppedTxDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDroppedTxDeltaMin
moClass: adaptor:VnicStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/vnic-stats
tcaAdaptorDroppedTxDeltaMax
Fault Code: F34170
Message
Threshold Crossed: adaptor:VnicStats property: droppedTxDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDroppedTxDeltaMax
moClass: adaptor:VnicStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/vnic-stats
tcaAdaptorDroppedTxDeltaAvg
Fault Code: F34171
Message
Threshold Crossed: adaptor:VnicStats property: droppedTxDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDroppedTxDeltaAvg
moClass: adaptor:VnicStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/vnic-stats
tcaAdaptorDroppedRxDelta
Fault Code: F34178
Message
Threshold Crossed: adaptor:VnicStats property: droppedRxDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDroppedRxDelta
moClass: adaptor:VnicStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/vnic-stats
tcaAdaptorDroppedRxDeltaMin
Fault Code: F34179
Message
Threshold Crossed: adaptor:VnicStats property: droppedRxDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDroppedRxDeltaMin
moClass: adaptor:VnicStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/vnic-stats
tcaAdaptorDroppedRxDeltaMax
Fault Code: F34180
Message
Threshold Crossed: adaptor:VnicStats property: droppedRxDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDroppedRxDeltaMax
moClass: adaptor:VnicStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/vnic-stats
tcaAdaptorDroppedRxDeltaAvg
Fault Code: F34181
Message
Threshold Crossed: adaptor:VnicStats property: droppedRxDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDroppedRxDeltaAvg
moClass: adaptor:VnicStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-scsi-[id]/vnic-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vnic-stats
Affected MO: vmm/computeEp-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/hv-[uuid]/nic-[name]/vnic-stats
Affected MO: vmm/vm-[uuid]/nic-[name]/vnic-stats
tcaAdaptorInputRequestsDelta
Fault Code: F34192
Message
Threshold Crossed: adaptor:FcIfFC4Stats property: inputRequestsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorInputRequestsDelta
moClass: adaptor:FcIfFC4Stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
tcaAdaptorInputRequestsDeltaMin
Fault Code: F34193
Message
Threshold Crossed: adaptor:FcIfFC4Stats property: inputRequestsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorInputRequestsDeltaMin
moClass: adaptor:FcIfFC4Stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
tcaAdaptorInputRequestsDeltaMax
Fault Code: F34194
Message
Threshold Crossed: adaptor:FcIfFC4Stats property: inputRequestsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorInputRequestsDeltaMax
moClass: adaptor:FcIfFC4Stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
tcaAdaptorInputRequestsDeltaAvg
Fault Code: F34195
Message
Threshold Crossed: adaptor:FcIfFC4Stats property: inputRequestsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorInputRequestsDeltaAvg
moClass: adaptor:FcIfFC4Stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
tcaAdaptorOutputRequestsDelta
Fault Code: F34202
Message
Threshold Crossed: adaptor:FcIfFC4Stats property: outputRequestsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorOutputRequestsDelta
moClass: adaptor:FcIfFC4Stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
tcaAdaptorOutputRequestsDeltaMin
Fault Code: F34203
Message
Threshold Crossed: adaptor:FcIfFC4Stats property: outputRequestsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorOutputRequestsDeltaMin
moClass: adaptor:FcIfFC4Stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
tcaAdaptorOutputRequestsDeltaMax
Fault Code: F34204
Message
Threshold Crossed: adaptor:FcIfFC4Stats property: outputRequestsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorOutputRequestsDeltaMax
moClass: adaptor:FcIfFC4Stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
tcaAdaptorOutputRequestsDeltaAvg
Fault Code: F34205
Message
Threshold Crossed: adaptor:FcIfFC4Stats property: outputRequestsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorOutputRequestsDeltaAvg
moClass: adaptor:FcIfFC4Stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
tcaAdaptorControlRequestsDelta
Fault Code: F34212
Message
Threshold Crossed: adaptor:FcIfFC4Stats property: controlRequestsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorControlRequestsDelta
moClass: adaptor:FcIfFC4Stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
tcaAdaptorControlRequestsDeltaMin
Fault Code: F34213
Message
Threshold Crossed: adaptor:FcIfFC4Stats property: controlRequestsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorControlRequestsDeltaMin
moClass: adaptor:FcIfFC4Stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
tcaAdaptorControlRequestsDeltaMax
Fault Code: F34214
Message
Threshold Crossed: adaptor:FcIfFC4Stats property: controlRequestsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorControlRequestsDeltaMax
moClass: adaptor:FcIfFC4Stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
tcaAdaptorControlRequestsDeltaAvg
Fault Code: F34215
Message
Threshold Crossed: adaptor:FcIfFC4Stats property: controlRequestsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorControlRequestsDeltaAvg
moClass: adaptor:FcIfFC4Stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
tcaAdaptorInputMegabytesDelta
Fault Code: F34222
Message
Threshold Crossed: adaptor:FcIfFC4Stats property: inputMegabytesDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorInputMegabytesDelta
moClass: adaptor:FcIfFC4Stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
tcaAdaptorInputMegabytesDeltaMin
Fault Code: F34223
Message
Threshold Crossed: adaptor:FcIfFC4Stats property: inputMegabytesDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorInputMegabytesDeltaMin
moClass: adaptor:FcIfFC4Stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
tcaAdaptorInputMegabytesDeltaMax
Fault Code: F34224
Message
Threshold Crossed: adaptor:FcIfFC4Stats property: inputMegabytesDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorInputMegabytesDeltaMax
moClass: adaptor:FcIfFC4Stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
tcaAdaptorInputMegabytesDeltaAvg
Fault Code: F34225
Message
Threshold Crossed: adaptor:FcIfFC4Stats property: inputMegabytesDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorInputMegabytesDeltaAvg
moClass: adaptor:FcIfFC4Stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
tcaAdaptorOutputMegabytesDelta
Fault Code: F34232
Message
Threshold Crossed: adaptor:FcIfFC4Stats property: outputMegabytesDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorOutputMegabytesDelta
moClass: adaptor:FcIfFC4Stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
tcaAdaptorOutputMegabytesDeltaMin
Fault Code: F34233
Message
Threshold Crossed: adaptor:FcIfFC4Stats property: outputMegabytesDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorOutputMegabytesDeltaMin
moClass: adaptor:FcIfFC4Stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
tcaAdaptorOutputMegabytesDeltaMax
Fault Code: F34234
Message
Threshold Crossed: adaptor:FcIfFC4Stats property: outputMegabytesDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorOutputMegabytesDeltaMax
moClass: adaptor:FcIfFC4Stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
tcaAdaptorOutputMegabytesDeltaAvg
Fault Code: F34235
Message
Threshold Crossed: adaptor:FcIfFC4Stats property: outputMegabytesDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorOutputMegabytesDeltaAvg
moClass: adaptor:FcIfFC4Stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-fc4-stats
tcaAdaptorCorrectableErrorsDelta
Fault Code: F34246
Message
Threshold Crossed: adaptor:MenloBaseErrorStats property: correctableErrorsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorCorrectableErrorsDelta
moClass: adaptor:MenloBaseErrorStats
tcaAdaptorCorrectableErrorsDeltaMin
Fault Code: F34247
Message
Threshold Crossed: adaptor:MenloBaseErrorStats property: correctableErrorsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorCorrectableErrorsDeltaMin
moClass: adaptor:MenloBaseErrorStats
tcaAdaptorCorrectableErrorsDeltaMax
Fault Code: F34248
Message
Threshold Crossed: adaptor:MenloBaseErrorStats property: correctableErrorsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorCorrectableErrorsDeltaMax
moClass: adaptor:MenloBaseErrorStats
tcaAdaptorCorrectableErrorsDeltaAvg
Fault Code: F34249
Message
Threshold Crossed: adaptor:MenloBaseErrorStats property: correctableErrorsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorCorrectableErrorsDeltaAvg
moClass: adaptor:MenloBaseErrorStats
tcaAdaptorUncorrectableErrorsDelta
Fault Code: F34256
Message
Threshold Crossed: adaptor:MenloBaseErrorStats property: uncorrectableErrorsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorUncorrectableErrorsDelta
moClass: adaptor:MenloBaseErrorStats
tcaAdaptorUncorrectableErrorsDeltaMin
Fault Code: F34257
Message
Threshold Crossed: adaptor:MenloBaseErrorStats property: uncorrectableErrorsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorUncorrectableErrorsDeltaMin
moClass: adaptor:MenloBaseErrorStats
tcaAdaptorUncorrectableErrorsDeltaMax
Fault Code: F34258
Message
Threshold Crossed: adaptor:MenloBaseErrorStats property: uncorrectableErrorsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorUncorrectableErrorsDeltaMax
moClass: adaptor:MenloBaseErrorStats
tcaAdaptorUncorrectableErrorsDeltaAvg
Fault Code: F34259
Message
Threshold Crossed: adaptor:MenloBaseErrorStats property: uncorrectableErrorsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorUncorrectableErrorsDeltaAvg
moClass: adaptor:MenloBaseErrorStats
tcaAdaptorDropAclDelta
Fault Code: F34271
Message
Threshold Crossed: adaptor:MenloMcpuStats property: dropAclDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropAclDelta
moClass: adaptor:MenloMcpuStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
tcaAdaptorDropAclDeltaMin
Fault Code: F34272
Message
Threshold Crossed: adaptor:MenloMcpuStats property: dropAclDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropAclDeltaMin
moClass: adaptor:MenloMcpuStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
tcaAdaptorDropAclDeltaMax
Fault Code: F34273
Message
Threshold Crossed: adaptor:MenloMcpuStats property: dropAclDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropAclDeltaMax
moClass: adaptor:MenloMcpuStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
tcaAdaptorDropAclDeltaAvg
Fault Code: F34274
Message
Threshold Crossed: adaptor:MenloMcpuStats property: dropAclDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropAclDeltaAvg
moClass: adaptor:MenloMcpuStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
tcaAdaptorDropOverrunDelta
Fault Code: F34281
Message
Threshold Crossed: adaptor:MenloMcpuStats property: dropOverrunDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropOverrunDelta
moClass: adaptor:MenloMcpuStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
tcaAdaptorDropOverrunDeltaMin
Fault Code: F34282
Message
Threshold Crossed: adaptor:MenloMcpuStats property: dropOverrunDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropOverrunDeltaMin
moClass: adaptor:MenloMcpuStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
tcaAdaptorDropOverrunDeltaMax
Fault Code: F34283
Message
Threshold Crossed: adaptor:MenloMcpuStats property: dropOverrunDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropOverrunDeltaMax
moClass: adaptor:MenloMcpuStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
tcaAdaptorDropOverrunDeltaAvg
Fault Code: F34284
Message
Threshold Crossed: adaptor:MenloMcpuStats property: dropOverrunDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropOverrunDeltaAvg
moClass: adaptor:MenloMcpuStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
tcaAdaptorDropRuntDelta
Fault Code: F34291
Message
Threshold Crossed: adaptor:MenloMcpuStats property: dropRuntDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropRuntDelta
moClass: adaptor:MenloMcpuStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
tcaAdaptorDropRuntDeltaMin
Fault Code: F34292
Message
Threshold Crossed: adaptor:MenloMcpuStats property: dropRuntDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropRuntDeltaMin
moClass: adaptor:MenloMcpuStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
tcaAdaptorDropRuntDeltaMax
Fault Code: F34293
Message
Threshold Crossed: adaptor:MenloMcpuStats property: dropRuntDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropRuntDeltaMax
moClass: adaptor:MenloMcpuStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
tcaAdaptorDropRuntDeltaAvg
Fault Code: F34294
Message
Threshold Crossed: adaptor:MenloMcpuStats property: dropRuntDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropRuntDeltaAvg
moClass: adaptor:MenloMcpuStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
tcaAdaptorTruncateOverrunDelta
Fault Code: F34301
Message
Threshold Crossed: adaptor:MenloMcpuStats property: truncateOverrunDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTruncateOverrunDelta
moClass: adaptor:MenloMcpuStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
tcaAdaptorTruncateOverrunDeltaMin
Fault Code: F34302
Message
Threshold Crossed: adaptor:MenloMcpuStats property: truncateOverrunDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTruncateOverrunDeltaMin
moClass: adaptor:MenloMcpuStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
tcaAdaptorTruncateOverrunDeltaMax
Fault Code: F34303
Message
Threshold Crossed: adaptor:MenloMcpuStats property: truncateOverrunDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTruncateOverrunDeltaMax
moClass: adaptor:MenloMcpuStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
tcaAdaptorTruncateOverrunDeltaAvg
Fault Code: F34304
Message
Threshold Crossed: adaptor:MenloMcpuStats property: truncateOverrunDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTruncateOverrunDeltaAvg
moClass: adaptor:MenloMcpuStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-mcpu-stats-[menloMcpuIndex]
tcaAdaptorCorrectableErrorsDelta
Fault Code: F34316
Message
Threshold Crossed: adaptor:MenloMcpuErrorStats property: correctableErrorsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorCorrectableErrorsDelta
moClass: adaptor:MenloMcpuErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
tcaAdaptorCorrectableErrorsDeltaMin
Fault Code: F34317
Message
Threshold Crossed: adaptor:MenloMcpuErrorStats property: correctableErrorsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorCorrectableErrorsDeltaMin
moClass: adaptor:MenloMcpuErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
tcaAdaptorCorrectableErrorsDeltaMax
Fault Code: F34318
Message
Threshold Crossed: adaptor:MenloMcpuErrorStats property: correctableErrorsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorCorrectableErrorsDeltaMax
moClass: adaptor:MenloMcpuErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
tcaAdaptorCorrectableErrorsDeltaAvg
Fault Code: F34319
Message
Threshold Crossed: adaptor:MenloMcpuErrorStats property: correctableErrorsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorCorrectableErrorsDeltaAvg
moClass: adaptor:MenloMcpuErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
tcaAdaptorPopErrorsDelta
Fault Code: F34326
Message
Threshold Crossed: adaptor:MenloMcpuErrorStats property: popErrorsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPopErrorsDelta
moClass: adaptor:MenloMcpuErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
tcaAdaptorPopErrorsDeltaMin
Fault Code: F34327
Message
Threshold Crossed: adaptor:MenloMcpuErrorStats property: popErrorsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPopErrorsDeltaMin
moClass: adaptor:MenloMcpuErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
tcaAdaptorPopErrorsDeltaMax
Fault Code: F34328
Message
Threshold Crossed: adaptor:MenloMcpuErrorStats property: popErrorsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPopErrorsDeltaMax
moClass: adaptor:MenloMcpuErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
tcaAdaptorPopErrorsDeltaAvg
Fault Code: F34329
Message
Threshold Crossed: adaptor:MenloMcpuErrorStats property: popErrorsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPopErrorsDeltaAvg
moClass: adaptor:MenloMcpuErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
tcaAdaptorPushErrorsDelta
Fault Code: F34336
Message
Threshold Crossed: adaptor:MenloMcpuErrorStats property: pushErrorsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPushErrorsDelta
moClass: adaptor:MenloMcpuErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
tcaAdaptorPushErrorsDeltaMin
Fault Code: F34337
Message
Threshold Crossed: adaptor:MenloMcpuErrorStats property: pushErrorsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPushErrorsDeltaMin
moClass: adaptor:MenloMcpuErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
tcaAdaptorPushErrorsDeltaMax
Fault Code: F34338
Message
Threshold Crossed: adaptor:MenloMcpuErrorStats property: pushErrorsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPushErrorsDeltaMax
moClass: adaptor:MenloMcpuErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
tcaAdaptorPushErrorsDeltaAvg
Fault Code: F34339
Message
Threshold Crossed: adaptor:MenloMcpuErrorStats property: pushErrorsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPushErrorsDeltaAvg
moClass: adaptor:MenloMcpuErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
tcaAdaptorUncorrectableErrorsDelta
Fault Code: F34346
Message
Threshold Crossed: adaptor:MenloMcpuErrorStats property: uncorrectableErrorsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorUncorrectableErrorsDelta
moClass: adaptor:MenloMcpuErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
tcaAdaptorUncorrectableErrorsDeltaMin
Fault Code: F34347
Message
Threshold Crossed: adaptor:MenloMcpuErrorStats property: uncorrectableErrorsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorUncorrectableErrorsDeltaMin
moClass: adaptor:MenloMcpuErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
tcaAdaptorUncorrectableErrorsDeltaMax
Fault Code: F34348
Message
Threshold Crossed: adaptor:MenloMcpuErrorStats property: uncorrectableErrorsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorUncorrectableErrorsDeltaMax
moClass: adaptor:MenloMcpuErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
tcaAdaptorUncorrectableErrorsDeltaAvg
Fault Code: F34349
Message
Threshold Crossed: adaptor:MenloMcpuErrorStats property: uncorrectableErrorsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorUncorrectableErrorsDeltaAvg
moClass: adaptor:MenloMcpuErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-mcpu-error-stats-[menloMcpuIndex]
tcaAdaptorDropOverrunDelta
Fault Code: F34361
Message
Threshold Crossed: adaptor:MenloEthStats property: dropOverrunDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropOverrunDelta
moClass: adaptor:MenloEthStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-eth-stats-[menloEthIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-eth-stats-[menloEthIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-eth-stats-[menloEthIndex]
tcaAdaptorDropOverrunDeltaMin
Fault Code: F34362
Message
Threshold Crossed: adaptor:MenloEthStats property: dropOverrunDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropOverrunDeltaMin
moClass: adaptor:MenloEthStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-eth-stats-[menloEthIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-eth-stats-[menloEthIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-eth-stats-[menloEthIndex]
tcaAdaptorDropOverrunDeltaMax
Fault Code: F34363
Message
Threshold Crossed: adaptor:MenloEthStats property: dropOverrunDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropOverrunDeltaMax
moClass: adaptor:MenloEthStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-eth-stats-[menloEthIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-eth-stats-[menloEthIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-eth-stats-[menloEthIndex]
tcaAdaptorDropOverrunDeltaAvg
Fault Code: F34364
Message
Threshold Crossed: adaptor:MenloEthStats property: dropOverrunDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropOverrunDeltaAvg
moClass: adaptor:MenloEthStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-eth-stats-[menloEthIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-eth-stats-[menloEthIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-eth-stats-[menloEthIndex]
tcaAdaptorDropRuntDelta
Fault Code: F34371
Message
Threshold Crossed: adaptor:MenloEthStats property: dropRuntDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropRuntDelta
moClass: adaptor:MenloEthStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-eth-stats-[menloEthIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-eth-stats-[menloEthIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-eth-stats-[menloEthIndex]
tcaAdaptorDropRuntDeltaMin
Fault Code: F34372
Message
Threshold Crossed: adaptor:MenloEthStats property: dropRuntDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropRuntDeltaMin
moClass: adaptor:MenloEthStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-eth-stats-[menloEthIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-eth-stats-[menloEthIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-eth-stats-[menloEthIndex]
tcaAdaptorDropRuntDeltaMax
Fault Code: F34373
Message
Threshold Crossed: adaptor:MenloEthStats property: dropRuntDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropRuntDeltaMax
moClass: adaptor:MenloEthStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-eth-stats-[menloEthIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-eth-stats-[menloEthIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-eth-stats-[menloEthIndex]
tcaAdaptorDropRuntDeltaAvg
Fault Code: F34374
Message
Threshold Crossed: adaptor:MenloEthStats property: dropRuntDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropRuntDeltaAvg
moClass: adaptor:MenloEthStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-eth-stats-[menloEthIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-eth-stats-[menloEthIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-eth-stats-[menloEthIndex]
tcaAdaptorTruncateOverrunDelta
Fault Code: F34381
Message
Threshold Crossed: adaptor:MenloEthStats property: truncateOverrunDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTruncateOverrunDelta
moClass: adaptor:MenloEthStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-eth-stats-[menloEthIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-eth-stats-[menloEthIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-eth-stats-[menloEthIndex]
tcaAdaptorTruncateOverrunDeltaMin
Fault Code: F34382
Message
Threshold Crossed: adaptor:MenloEthStats property: truncateOverrunDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTruncateOverrunDeltaMin
moClass: adaptor:MenloEthStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-eth-stats-[menloEthIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-eth-stats-[menloEthIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-eth-stats-[menloEthIndex]
tcaAdaptorTruncateOverrunDeltaMax
Fault Code: F34383
Message
Threshold Crossed: adaptor:MenloEthStats property: truncateOverrunDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTruncateOverrunDeltaMax
moClass: adaptor:MenloEthStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-eth-stats-[menloEthIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-eth-stats-[menloEthIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-eth-stats-[menloEthIndex]
tcaAdaptorTruncateOverrunDeltaAvg
Fault Code: F34384
Message
Threshold Crossed: adaptor:MenloEthStats property: truncateOverrunDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTruncateOverrunDeltaAvg
moClass: adaptor:MenloEthStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-eth-stats-[menloEthIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-eth-stats-[menloEthIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-eth-stats-[menloEthIndex]
tcaAdaptorCorrectableErrorsDelta
Fault Code: F34396
Message
Threshold Crossed: adaptor:MenloEthErrorStats property: correctableErrorsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorCorrectableErrorsDelta
moClass: adaptor:MenloEthErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
tcaAdaptorCorrectableErrorsDeltaMin
Fault Code: F34397
Message
Threshold Crossed: adaptor:MenloEthErrorStats property: correctableErrorsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorCorrectableErrorsDeltaMin
moClass: adaptor:MenloEthErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
tcaAdaptorCorrectableErrorsDeltaMax
Fault Code: F34398
Message
Threshold Crossed: adaptor:MenloEthErrorStats property: correctableErrorsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorCorrectableErrorsDeltaMax
moClass: adaptor:MenloEthErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
tcaAdaptorCorrectableErrorsDeltaAvg
Fault Code: F34399
Message
Threshold Crossed: adaptor:MenloEthErrorStats property: correctableErrorsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorCorrectableErrorsDeltaAvg
moClass: adaptor:MenloEthErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
tcaAdaptorDropAclDelta
Fault Code: F34406
Message
Threshold Crossed: adaptor:MenloEthErrorStats property: dropAclDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropAclDelta
moClass: adaptor:MenloEthErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
tcaAdaptorDropAclDeltaMin
Fault Code: F34407
Message
Threshold Crossed: adaptor:MenloEthErrorStats property: dropAclDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropAclDeltaMin
moClass: adaptor:MenloEthErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
tcaAdaptorDropAclDeltaMax
Fault Code: F34408
Message
Threshold Crossed: adaptor:MenloEthErrorStats property: dropAclDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropAclDeltaMax
moClass: adaptor:MenloEthErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
tcaAdaptorDropAclDeltaAvg
Fault Code: F34409
Message
Threshold Crossed: adaptor:MenloEthErrorStats property: dropAclDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropAclDeltaAvg
moClass: adaptor:MenloEthErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
tcaAdaptorPopErrorsDelta
Fault Code: F34416
Message
Threshold Crossed: adaptor:MenloEthErrorStats property: popErrorsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPopErrorsDelta
moClass: adaptor:MenloEthErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
tcaAdaptorPopErrorsDeltaMin
Fault Code: F34417
Message
Threshold Crossed: adaptor:MenloEthErrorStats property: popErrorsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPopErrorsDeltaMin
moClass: adaptor:MenloEthErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
tcaAdaptorPopErrorsDeltaMax
Fault Code: F34418
Message
Threshold Crossed: adaptor:MenloEthErrorStats property: popErrorsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPopErrorsDeltaMax
moClass: adaptor:MenloEthErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
tcaAdaptorPopErrorsDeltaAvg
Fault Code: F34419
Message
Threshold Crossed: adaptor:MenloEthErrorStats property: popErrorsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPopErrorsDeltaAvg
moClass: adaptor:MenloEthErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
tcaAdaptorPushErrorsDelta
Fault Code: F34426
Message
Threshold Crossed: adaptor:MenloEthErrorStats property: pushErrorsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPushErrorsDelta
moClass: adaptor:MenloEthErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
tcaAdaptorPushErrorsDeltaMin
Fault Code: F34427
Message
Threshold Crossed: adaptor:MenloEthErrorStats property: pushErrorsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPushErrorsDeltaMin
moClass: adaptor:MenloEthErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
tcaAdaptorPushErrorsDeltaMax
Fault Code: F34428
Message
Threshold Crossed: adaptor:MenloEthErrorStats property: pushErrorsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPushErrorsDeltaMax
moClass: adaptor:MenloEthErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
tcaAdaptorPushErrorsDeltaAvg
Fault Code: F34429
Message
Threshold Crossed: adaptor:MenloEthErrorStats property: pushErrorsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPushErrorsDeltaAvg
moClass: adaptor:MenloEthErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
tcaAdaptorUncorrectableErrorsDelta
Fault Code: F34436
Message
Threshold Crossed: adaptor:MenloEthErrorStats property: uncorrectableErrorsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorUncorrectableErrorsDelta
moClass: adaptor:MenloEthErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
tcaAdaptorUncorrectableErrorsDeltaMin
Fault Code: F34437
Message
Threshold Crossed: adaptor:MenloEthErrorStats property: uncorrectableErrorsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorUncorrectableErrorsDeltaMin
moClass: adaptor:MenloEthErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
tcaAdaptorUncorrectableErrorsDeltaMax
Fault Code: F34438
Message
Threshold Crossed: adaptor:MenloEthErrorStats property: uncorrectableErrorsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorUncorrectableErrorsDeltaMax
moClass: adaptor:MenloEthErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
tcaAdaptorUncorrectableErrorsDeltaAvg
Fault Code: F34439
Message
Threshold Crossed: adaptor:MenloEthErrorStats property: uncorrectableErrorsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorUncorrectableErrorsDeltaAvg
moClass: adaptor:MenloEthErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-eth-error-stats-[menloEthIndex]
tcaAdaptorDropAclDelta
Fault Code: F34451
Message
Threshold Crossed: adaptor:MenloFcStats property: dropAclDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropAclDelta
moClass: adaptor:MenloFcStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
tcaAdaptorDropAclDeltaMin
Fault Code: F34452
Message
Threshold Crossed: adaptor:MenloFcStats property: dropAclDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropAclDeltaMin
moClass: adaptor:MenloFcStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
tcaAdaptorDropAclDeltaMax
Fault Code: F34453
Message
Threshold Crossed: adaptor:MenloFcStats property: dropAclDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropAclDeltaMax
moClass: adaptor:MenloFcStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
tcaAdaptorDropAclDeltaAvg
Fault Code: F34454
Message
Threshold Crossed: adaptor:MenloFcStats property: dropAclDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropAclDeltaAvg
moClass: adaptor:MenloFcStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
tcaAdaptorDropOverrunDelta
Fault Code: F34461
Message
Threshold Crossed: adaptor:MenloFcStats property: dropOverrunDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropOverrunDelta
moClass: adaptor:MenloFcStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
tcaAdaptorDropOverrunDeltaMin
Fault Code: F34462
Message
Threshold Crossed: adaptor:MenloFcStats property: dropOverrunDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropOverrunDeltaMin
moClass: adaptor:MenloFcStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
tcaAdaptorDropOverrunDeltaMax
Fault Code: F34463
Message
Threshold Crossed: adaptor:MenloFcStats property: dropOverrunDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropOverrunDeltaMax
moClass: adaptor:MenloFcStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
tcaAdaptorDropOverrunDeltaAvg
Fault Code: F34464
Message
Threshold Crossed: adaptor:MenloFcStats property: dropOverrunDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropOverrunDeltaAvg
moClass: adaptor:MenloFcStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
tcaAdaptorDropRuntDelta
Fault Code: F34471
Message
Threshold Crossed: adaptor:MenloFcStats property: dropRuntDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropRuntDelta
moClass: adaptor:MenloFcStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
tcaAdaptorDropRuntDeltaMin
Fault Code: F34472
Message
Threshold Crossed: adaptor:MenloFcStats property: dropRuntDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropRuntDeltaMin
moClass: adaptor:MenloFcStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
tcaAdaptorDropRuntDeltaMax
Fault Code: F34473
Message
Threshold Crossed: adaptor:MenloFcStats property: dropRuntDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropRuntDeltaMax
moClass: adaptor:MenloFcStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
tcaAdaptorDropRuntDeltaAvg
Fault Code: F34474
Message
Threshold Crossed: adaptor:MenloFcStats property: dropRuntDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropRuntDeltaAvg
moClass: adaptor:MenloFcStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
tcaAdaptorTruncateOverrunDelta
Fault Code: F34481
Message
Threshold Crossed: adaptor:MenloFcStats property: truncateOverrunDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTruncateOverrunDelta
moClass: adaptor:MenloFcStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
tcaAdaptorTruncateOverrunDeltaMin
Fault Code: F34482
Message
Threshold Crossed: adaptor:MenloFcStats property: truncateOverrunDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTruncateOverrunDeltaMin
moClass: adaptor:MenloFcStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
tcaAdaptorTruncateOverrunDeltaMax
Fault Code: F34483
Message
Threshold Crossed: adaptor:MenloFcStats property: truncateOverrunDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTruncateOverrunDeltaMax
moClass: adaptor:MenloFcStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
tcaAdaptorTruncateOverrunDeltaAvg
Fault Code: F34484
Message
Threshold Crossed: adaptor:MenloFcStats property: truncateOverrunDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTruncateOverrunDeltaAvg
moClass: adaptor:MenloFcStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-fc-stats-[menloFcIndex]
tcaAdaptorCorrectableErrorsDelta
Fault Code: F34496
Message
Threshold Crossed: adaptor:MenloFcErrorStats property: correctableErrorsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorCorrectableErrorsDelta
moClass: adaptor:MenloFcErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
tcaAdaptorCorrectableErrorsDeltaMin
Fault Code: F34497
Message
Threshold Crossed: adaptor:MenloFcErrorStats property: correctableErrorsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorCorrectableErrorsDeltaMin
moClass: adaptor:MenloFcErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
tcaAdaptorCorrectableErrorsDeltaMax
Fault Code: F34498
Message
Threshold Crossed: adaptor:MenloFcErrorStats property: correctableErrorsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorCorrectableErrorsDeltaMax
moClass: adaptor:MenloFcErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
tcaAdaptorCorrectableErrorsDeltaAvg
Fault Code: F34499
Message
Threshold Crossed: adaptor:MenloFcErrorStats property: correctableErrorsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorCorrectableErrorsDeltaAvg
moClass: adaptor:MenloFcErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
tcaAdaptorPopErrorsDelta
Fault Code: F34506
Message
Threshold Crossed: adaptor:MenloFcErrorStats property: popErrorsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPopErrorsDelta
moClass: adaptor:MenloFcErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
tcaAdaptorPopErrorsDeltaMin
Fault Code: F34507
Message
Threshold Crossed: adaptor:MenloFcErrorStats property: popErrorsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPopErrorsDeltaMin
moClass: adaptor:MenloFcErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
tcaAdaptorPopErrorsDeltaMax
Fault Code: F34508
Message
Threshold Crossed: adaptor:MenloFcErrorStats property: popErrorsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPopErrorsDeltaMax
moClass: adaptor:MenloFcErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
tcaAdaptorPopErrorsDeltaAvg
Fault Code: F34509
Message
Threshold Crossed: adaptor:MenloFcErrorStats property: popErrorsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPopErrorsDeltaAvg
moClass: adaptor:MenloFcErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
tcaAdaptorPushErrorsDelta
Fault Code: F34516
Message
Threshold Crossed: adaptor:MenloFcErrorStats property: pushErrorsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPushErrorsDelta
moClass: adaptor:MenloFcErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
tcaAdaptorPushErrorsDeltaMin
Fault Code: F34517
Message
Threshold Crossed: adaptor:MenloFcErrorStats property: pushErrorsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPushErrorsDeltaMin
moClass: adaptor:MenloFcErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
tcaAdaptorPushErrorsDeltaMax
Fault Code: F34518
Message
Threshold Crossed: adaptor:MenloFcErrorStats property: pushErrorsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPushErrorsDeltaMax
moClass: adaptor:MenloFcErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
tcaAdaptorPushErrorsDeltaAvg
Fault Code: F34519
Message
Threshold Crossed: adaptor:MenloFcErrorStats property: pushErrorsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPushErrorsDeltaAvg
moClass: adaptor:MenloFcErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
tcaAdaptorUncorrectableErrorsDelta
Fault Code: F34526
Message
Threshold Crossed: adaptor:MenloFcErrorStats property: uncorrectableErrorsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorUncorrectableErrorsDelta
moClass: adaptor:MenloFcErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
tcaAdaptorUncorrectableErrorsDeltaMin
Fault Code: F34527
Message
Threshold Crossed: adaptor:MenloFcErrorStats property: uncorrectableErrorsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorUncorrectableErrorsDeltaMin
moClass: adaptor:MenloFcErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
tcaAdaptorUncorrectableErrorsDeltaMax
Fault Code: F34528
Message
Threshold Crossed: adaptor:MenloFcErrorStats property: uncorrectableErrorsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorUncorrectableErrorsDeltaMax
moClass: adaptor:MenloFcErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
tcaAdaptorUncorrectableErrorsDeltaAvg
Fault Code: F34529
Message
Threshold Crossed: adaptor:MenloFcErrorStats property: uncorrectableErrorsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorUncorrectableErrorsDeltaAvg
moClass: adaptor:MenloFcErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-fc-error-stats-[menloFcIndex]
tcaAdaptorDropOverrunN0Delta
Fault Code: F34542
Message
Threshold Crossed: adaptor:MenloQStats property: dropOverrunN0Delta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropOverrunN0Delta
moClass: adaptor:MenloQStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
tcaAdaptorDropOverrunN0DeltaMin
Fault Code: F34543
Message
Threshold Crossed: adaptor:MenloQStats property: dropOverrunN0DeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropOverrunN0DeltaMin
moClass: adaptor:MenloQStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
tcaAdaptorDropOverrunN0DeltaMax
Fault Code: F34544
Message
Threshold Crossed: adaptor:MenloQStats property: dropOverrunN0DeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropOverrunN0DeltaMax
moClass: adaptor:MenloQStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
tcaAdaptorDropOverrunN0DeltaAvg
Fault Code: F34545
Message
Threshold Crossed: adaptor:MenloQStats property: dropOverrunN0DeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropOverrunN0DeltaAvg
moClass: adaptor:MenloQStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
tcaAdaptorDropOverrunN1Delta
Fault Code: F34552
Message
Threshold Crossed: adaptor:MenloQStats property: dropOverrunN1Delta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropOverrunN1Delta
moClass: adaptor:MenloQStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
tcaAdaptorDropOverrunN1DeltaMin
Fault Code: F34553
Message
Threshold Crossed: adaptor:MenloQStats property: dropOverrunN1DeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropOverrunN1DeltaMin
moClass: adaptor:MenloQStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
tcaAdaptorDropOverrunN1DeltaMax
Fault Code: F34554
Message
Threshold Crossed: adaptor:MenloQStats property: dropOverrunN1DeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropOverrunN1DeltaMax
moClass: adaptor:MenloQStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
tcaAdaptorDropOverrunN1DeltaAvg
Fault Code: F34555
Message
Threshold Crossed: adaptor:MenloQStats property: dropOverrunN1DeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropOverrunN1DeltaAvg
moClass: adaptor:MenloQStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
tcaAdaptorTruncateOverrunN0Delta
Fault Code: F34562
Message
Threshold Crossed: adaptor:MenloQStats property: truncateOverrunN0Delta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTruncateOverrunN0Delta
moClass: adaptor:MenloQStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
tcaAdaptorTruncateOverrunN0DeltaMin
Fault Code: F34563
Message
Threshold Crossed: adaptor:MenloQStats property: truncateOverrunN0DeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTruncateOverrunN0DeltaMin
moClass: adaptor:MenloQStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
tcaAdaptorTruncateOverrunN0DeltaMax
Fault Code: F34564
Message
Threshold Crossed: adaptor:MenloQStats property: truncateOverrunN0DeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTruncateOverrunN0DeltaMax
moClass: adaptor:MenloQStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
tcaAdaptorTruncateOverrunN0DeltaAvg
Fault Code: F34565
Message
Threshold Crossed: adaptor:MenloQStats property: truncateOverrunN0DeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTruncateOverrunN0DeltaAvg
moClass: adaptor:MenloQStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
tcaAdaptorTruncateOverrunN1Delta
Fault Code: F34572
Message
Threshold Crossed: adaptor:MenloQStats property: truncateOverrunN1Delta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTruncateOverrunN1Delta
moClass: adaptor:MenloQStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
tcaAdaptorTruncateOverrunN1DeltaMin
Fault Code: F34573
Message
Threshold Crossed: adaptor:MenloQStats property: truncateOverrunN1DeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTruncateOverrunN1DeltaMin
moClass: adaptor:MenloQStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
tcaAdaptorTruncateOverrunN1DeltaMax
Fault Code: F34574
Message
Threshold Crossed: adaptor:MenloQStats property: truncateOverrunN1DeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTruncateOverrunN1DeltaMax
moClass: adaptor:MenloQStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
tcaAdaptorTruncateOverrunN1DeltaAvg
Fault Code: F34575
Message
Threshold Crossed: adaptor:MenloQStats property: truncateOverrunN1DeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTruncateOverrunN1DeltaAvg
moClass: adaptor:MenloQStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-q-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
tcaAdaptorCorrectableErrorsDelta
Fault Code: F34588
Message
Threshold Crossed: adaptor:MenloQErrorStats property: correctableErrorsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorCorrectableErrorsDelta
moClass: adaptor:MenloQErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
tcaAdaptorCorrectableErrorsDeltaMin
Fault Code: F34589
Message
Threshold Crossed: adaptor:MenloQErrorStats property: correctableErrorsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorCorrectableErrorsDeltaMin
moClass: adaptor:MenloQErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
tcaAdaptorCorrectableErrorsDeltaMax
Fault Code: F34590
Message
Threshold Crossed: adaptor:MenloQErrorStats property: correctableErrorsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorCorrectableErrorsDeltaMax
moClass: adaptor:MenloQErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
tcaAdaptorCorrectableErrorsDeltaAvg
Fault Code: F34591
Message
Threshold Crossed: adaptor:MenloQErrorStats property: correctableErrorsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorCorrectableErrorsDeltaAvg
moClass: adaptor:MenloQErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
tcaAdaptorPopErrorsDelta
Fault Code: F34598
Message
Threshold Crossed: adaptor:MenloQErrorStats property: popErrorsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPopErrorsDelta
moClass: adaptor:MenloQErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
tcaAdaptorPopErrorsDeltaMin
Fault Code: F34599
Message
Threshold Crossed: adaptor:MenloQErrorStats property: popErrorsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPopErrorsDeltaMin
moClass: adaptor:MenloQErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
tcaAdaptorPopErrorsDeltaMax
Fault Code: F34600
Message
Threshold Crossed: adaptor:MenloQErrorStats property: popErrorsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPopErrorsDeltaMax
moClass: adaptor:MenloQErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
tcaAdaptorPopErrorsDeltaAvg
Fault Code: F34601
Message
Threshold Crossed: adaptor:MenloQErrorStats property: popErrorsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPopErrorsDeltaAvg
moClass: adaptor:MenloQErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
tcaAdaptorPushErrorsDelta
Fault Code: F34608
Message
Threshold Crossed: adaptor:MenloQErrorStats property: pushErrorsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPushErrorsDelta
moClass: adaptor:MenloQErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
tcaAdaptorPushErrorsDeltaMin
Fault Code: F34609
Message
Threshold Crossed: adaptor:MenloQErrorStats property: pushErrorsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPushErrorsDeltaMin
moClass: adaptor:MenloQErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
tcaAdaptorPushErrorsDeltaMax
Fault Code: F34610
Message
Threshold Crossed: adaptor:MenloQErrorStats property: pushErrorsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPushErrorsDeltaMax
moClass: adaptor:MenloQErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
tcaAdaptorPushErrorsDeltaAvg
Fault Code: F34611
Message
Threshold Crossed: adaptor:MenloQErrorStats property: pushErrorsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorPushErrorsDeltaAvg
moClass: adaptor:MenloQErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
tcaAdaptorUncorrectableErrorsDelta
Fault Code: F34618
Message
Threshold Crossed: adaptor:MenloQErrorStats property: uncorrectableErrorsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorUncorrectableErrorsDelta
moClass: adaptor:MenloQErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
tcaAdaptorUncorrectableErrorsDeltaMin
Fault Code: F34619
Message
Threshold Crossed: adaptor:MenloQErrorStats property: uncorrectableErrorsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorUncorrectableErrorsDeltaMin
moClass: adaptor:MenloQErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
tcaAdaptorUncorrectableErrorsDeltaMax
Fault Code: F34620
Message
Threshold Crossed: adaptor:MenloQErrorStats property: uncorrectableErrorsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorUncorrectableErrorsDeltaMax
moClass: adaptor:MenloQErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
tcaAdaptorUncorrectableErrorsDeltaAvg
Fault Code: F34621
Message
Threshold Crossed: adaptor:MenloQErrorStats property: uncorrectableErrorsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorUncorrectableErrorsDeltaAvg
moClass: adaptor:MenloQErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-q-error-stats-comp-[menloQueueComponent]index-[menloQueueIndex]
tcaAdaptorLearnReqDropDelta
Fault Code: F34633
Message
Threshold Crossed: adaptor:MenloNetEgStats property: learnReqDropDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLearnReqDropDelta
moClass: adaptor:MenloNetEgStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
tcaAdaptorLearnReqDropDeltaMin
Fault Code: F34634
Message
Threshold Crossed: adaptor:MenloNetEgStats property: learnReqDropDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLearnReqDropDeltaMin
moClass: adaptor:MenloNetEgStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
tcaAdaptorLearnReqDropDeltaMax
Fault Code: F34635
Message
Threshold Crossed: adaptor:MenloNetEgStats property: learnReqDropDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLearnReqDropDeltaMax
moClass: adaptor:MenloNetEgStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
tcaAdaptorLearnReqDropDeltaAvg
Fault Code: F34636
Message
Threshold Crossed: adaptor:MenloNetEgStats property: learnReqDropDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLearnReqDropDeltaAvg
moClass: adaptor:MenloNetEgStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
tcaAdaptorDropCmdDelta
Fault Code: F34643
Message
Threshold Crossed: adaptor:MenloNetEgStats property: dropCmdDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropCmdDelta
moClass: adaptor:MenloNetEgStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
tcaAdaptorDropCmdDeltaMin
Fault Code: F34644
Message
Threshold Crossed: adaptor:MenloNetEgStats property: dropCmdDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropCmdDeltaMin
moClass: adaptor:MenloNetEgStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
tcaAdaptorDropCmdDeltaMax
Fault Code: F34645
Message
Threshold Crossed: adaptor:MenloNetEgStats property: dropCmdDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropCmdDeltaMax
moClass: adaptor:MenloNetEgStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
tcaAdaptorDropCmdDeltaAvg
Fault Code: F34646
Message
Threshold Crossed: adaptor:MenloNetEgStats property: dropCmdDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropCmdDeltaAvg
moClass: adaptor:MenloNetEgStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
tcaAdaptorDropLifCfgInvalidDelta
Fault Code: F34653
Message
Threshold Crossed: adaptor:MenloNetEgStats property: dropLifCfgInvalidDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropLifCfgInvalidDelta
moClass: adaptor:MenloNetEgStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
tcaAdaptorDropLifCfgInvalidDeltaMin
Fault Code: F34654
Message
Threshold Crossed: adaptor:MenloNetEgStats property: dropLifCfgInvalidDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropLifCfgInvalidDeltaMin
moClass: adaptor:MenloNetEgStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
tcaAdaptorDropLifCfgInvalidDeltaMax
Fault Code: F34655
Message
Threshold Crossed: adaptor:MenloNetEgStats property: dropLifCfgInvalidDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropLifCfgInvalidDeltaMax
moClass: adaptor:MenloNetEgStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
tcaAdaptorDropLifCfgInvalidDeltaAvg
Fault Code: F34656
Message
Threshold Crossed: adaptor:MenloNetEgStats property: dropLifCfgInvalidDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropLifCfgInvalidDeltaAvg
moClass: adaptor:MenloNetEgStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
tcaAdaptorDropLifMapNoHitDelta
Fault Code: F34663
Message
Threshold Crossed: adaptor:MenloNetEgStats property: dropLifMapNoHitDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropLifMapNoHitDelta
moClass: adaptor:MenloNetEgStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
tcaAdaptorDropLifMapNoHitDeltaMin
Fault Code: F34664
Message
Threshold Crossed: adaptor:MenloNetEgStats property: dropLifMapNoHitDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropLifMapNoHitDeltaMin
moClass: adaptor:MenloNetEgStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
tcaAdaptorDropLifMapNoHitDeltaMax
Fault Code: F34665
Message
Threshold Crossed: adaptor:MenloNetEgStats property: dropLifMapNoHitDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropLifMapNoHitDeltaMax
moClass: adaptor:MenloNetEgStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
tcaAdaptorDropLifMapNoHitDeltaAvg
Fault Code: F34666
Message
Threshold Crossed: adaptor:MenloNetEgStats property: dropLifMapNoHitDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropLifMapNoHitDeltaAvg
moClass: adaptor:MenloNetEgStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
tcaAdaptorDropSrcBindDelta
Fault Code: F34673
Message
Threshold Crossed: adaptor:MenloNetEgStats property: dropSrcBindDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropSrcBindDelta
moClass: adaptor:MenloNetEgStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
tcaAdaptorDropSrcBindDeltaMin
Fault Code: F34674
Message
Threshold Crossed: adaptor:MenloNetEgStats property: dropSrcBindDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropSrcBindDeltaMin
moClass: adaptor:MenloNetEgStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
tcaAdaptorDropSrcBindDeltaMax
Fault Code: F34675
Message
Threshold Crossed: adaptor:MenloNetEgStats property: dropSrcBindDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropSrcBindDeltaMax
moClass: adaptor:MenloNetEgStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
tcaAdaptorDropSrcBindDeltaAvg
Fault Code: F34676
Message
Threshold Crossed: adaptor:MenloNetEgStats property: dropSrcBindDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropSrcBindDeltaAvg
moClass: adaptor:MenloNetEgStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-net-eg-stats-[menloNetIndex]
tcaAdaptorFwdLookupNoHitDelta
Fault Code: F34688
Message
Threshold Crossed: adaptor:MenloNetInStats property: fwdLookupNoHitDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorFwdLookupNoHitDelta
moClass: adaptor:MenloNetInStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
tcaAdaptorFwdLookupNoHitDeltaMin
Fault Code: F34689
Message
Threshold Crossed: adaptor:MenloNetInStats property: fwdLookupNoHitDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorFwdLookupNoHitDeltaMin
moClass: adaptor:MenloNetInStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
tcaAdaptorFwdLookupNoHitDeltaMax
Fault Code: F34690
Message
Threshold Crossed: adaptor:MenloNetInStats property: fwdLookupNoHitDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorFwdLookupNoHitDeltaMax
moClass: adaptor:MenloNetInStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
tcaAdaptorFwdLookupNoHitDeltaAvg
Fault Code: F34691
Message
Threshold Crossed: adaptor:MenloNetInStats property: fwdLookupNoHitDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorFwdLookupNoHitDeltaAvg
moClass: adaptor:MenloNetInStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
tcaAdaptorDropFcMulticastDelta
Fault Code: F34698
Message
Threshold Crossed: adaptor:MenloNetInStats property: dropFcMulticastDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropFcMulticastDelta
moClass: adaptor:MenloNetInStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
tcaAdaptorDropFcMulticastDeltaMin
Fault Code: F34699
Message
Threshold Crossed: adaptor:MenloNetInStats property: dropFcMulticastDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropFcMulticastDeltaMin
moClass: adaptor:MenloNetInStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
tcaAdaptorDropFcMulticastDeltaMax
Fault Code: F34700
Message
Threshold Crossed: adaptor:MenloNetInStats property: dropFcMulticastDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropFcMulticastDeltaMax
moClass: adaptor:MenloNetInStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
tcaAdaptorDropFcMulticastDeltaAvg
Fault Code: F34701
Message
Threshold Crossed: adaptor:MenloNetInStats property: dropFcMulticastDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropFcMulticastDeltaAvg
moClass: adaptor:MenloNetInStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
tcaAdaptorDropFcLifInvalidDelta
Fault Code: F34708
Message
Threshold Crossed: adaptor:MenloNetInStats property: dropFcLifInvalidDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropFcLifInvalidDelta
moClass: adaptor:MenloNetInStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
tcaAdaptorDropFcLifInvalidDeltaMin
Fault Code: F34709
Message
Threshold Crossed: adaptor:MenloNetInStats property: dropFcLifInvalidDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropFcLifInvalidDeltaMin
moClass: adaptor:MenloNetInStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
tcaAdaptorDropFcLifInvalidDeltaMax
Fault Code: F34710
Message
Threshold Crossed: adaptor:MenloNetInStats property: dropFcLifInvalidDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropFcLifInvalidDeltaMax
moClass: adaptor:MenloNetInStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
tcaAdaptorDropFcLifInvalidDeltaAvg
Fault Code: F34711
Message
Threshold Crossed: adaptor:MenloNetInStats property: dropFcLifInvalidDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropFcLifInvalidDeltaAvg
moClass: adaptor:MenloNetInStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
tcaAdaptorDropNullPifDelta
Fault Code: F34718
Message
Threshold Crossed: adaptor:MenloNetInStats property: dropNullPifDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropNullPifDelta
moClass: adaptor:MenloNetInStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
tcaAdaptorDropNullPifDeltaMin
Fault Code: F34719
Message
Threshold Crossed: adaptor:MenloNetInStats property: dropNullPifDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropNullPifDeltaMin
moClass: adaptor:MenloNetInStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
tcaAdaptorDropNullPifDeltaMax
Fault Code: F34720
Message
Threshold Crossed: adaptor:MenloNetInStats property: dropNullPifDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropNullPifDeltaMax
moClass: adaptor:MenloNetInStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
tcaAdaptorDropNullPifDeltaAvg
Fault Code: F34721
Message
Threshold Crossed: adaptor:MenloNetInStats property: dropNullPifDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDropNullPifDeltaAvg
moClass: adaptor:MenloNetInStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-net-in-stats-[menloNetIndex]
tcaAdaptorRxPauseCFCDelta
Fault Code: F34733
Message
Threshold Crossed: adaptor:MenloHostPortStats property: rxPauseCFCDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxPauseCFCDelta
moClass: adaptor:MenloHostPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
tcaAdaptorRxPauseCFCDeltaMin
Fault Code: F34734
Message
Threshold Crossed: adaptor:MenloHostPortStats property: rxPauseCFCDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxPauseCFCDeltaMin
moClass: adaptor:MenloHostPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
tcaAdaptorRxPauseCFCDeltaMax
Fault Code: F34735
Message
Threshold Crossed: adaptor:MenloHostPortStats property: rxPauseCFCDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxPauseCFCDeltaMax
moClass: adaptor:MenloHostPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
tcaAdaptorRxPauseCFCDeltaAvg
Fault Code: F34736
Message
Threshold Crossed: adaptor:MenloHostPortStats property: rxPauseCFCDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxPauseCFCDeltaAvg
moClass: adaptor:MenloHostPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
tcaAdaptorRxPausePFCDelta
Fault Code: F34743
Message
Threshold Crossed: adaptor:MenloHostPortStats property: rxPausePFCDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxPausePFCDelta
moClass: adaptor:MenloHostPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
tcaAdaptorRxPausePFCDeltaMin
Fault Code: F34744
Message
Threshold Crossed: adaptor:MenloHostPortStats property: rxPausePFCDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxPausePFCDeltaMin
moClass: adaptor:MenloHostPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
tcaAdaptorRxPausePFCDeltaMax
Fault Code: F34745
Message
Threshold Crossed: adaptor:MenloHostPortStats property: rxPausePFCDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxPausePFCDeltaMax
moClass: adaptor:MenloHostPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
tcaAdaptorRxPausePFCDeltaAvg
Fault Code: F34746
Message
Threshold Crossed: adaptor:MenloHostPortStats property: rxPausePFCDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxPausePFCDeltaAvg
moClass: adaptor:MenloHostPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
tcaAdaptorTxPauseCFCDelta
Fault Code: F34753
Message
Threshold Crossed: adaptor:MenloHostPortStats property: txPauseCFCDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxPauseCFCDelta
moClass: adaptor:MenloHostPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
tcaAdaptorTxPauseCFCDeltaMin
Fault Code: F34754
Message
Threshold Crossed: adaptor:MenloHostPortStats property: txPauseCFCDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxPauseCFCDeltaMin
moClass: adaptor:MenloHostPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
tcaAdaptorTxPauseCFCDeltaMax
Fault Code: F34755
Message
Threshold Crossed: adaptor:MenloHostPortStats property: txPauseCFCDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxPauseCFCDeltaMax
moClass: adaptor:MenloHostPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
tcaAdaptorTxPauseCFCDeltaAvg
Fault Code: F34756
Message
Threshold Crossed: adaptor:MenloHostPortStats property: txPauseCFCDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxPauseCFCDeltaAvg
moClass: adaptor:MenloHostPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
tcaAdaptorTxPausePFCDelta
Fault Code: F34763
Message
Threshold Crossed: adaptor:MenloHostPortStats property: txPausePFCDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxPausePFCDelta
moClass: adaptor:MenloHostPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
tcaAdaptorTxPausePFCDeltaMin
Fault Code: F34764
Message
Threshold Crossed: adaptor:MenloHostPortStats property: txPausePFCDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxPausePFCDeltaMin
moClass: adaptor:MenloHostPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
tcaAdaptorTxPausePFCDeltaMax
Fault Code: F34765
Message
Threshold Crossed: adaptor:MenloHostPortStats property: txPausePFCDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxPausePFCDeltaMax
moClass: adaptor:MenloHostPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
tcaAdaptorTxPausePFCDeltaAvg
Fault Code: F34766
Message
Threshold Crossed: adaptor:MenloHostPortStats property: txPausePFCDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxPausePFCDeltaAvg
moClass: adaptor:MenloHostPortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-host-port-stats-[menloPortIndex]
tcaAdaptorRxPauseCFCDelta
Fault Code: F34778
Message
Threshold Crossed: adaptor:MenloDcePortStats property: rxPauseCFCDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxPauseCFCDelta
moClass: adaptor:MenloDcePortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
tcaAdaptorRxPauseCFCDeltaMin
Fault Code: F34779
Message
Threshold Crossed: adaptor:MenloDcePortStats property: rxPauseCFCDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxPauseCFCDeltaMin
moClass: adaptor:MenloDcePortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
tcaAdaptorRxPauseCFCDeltaMax
Fault Code: F34780
Message
Threshold Crossed: adaptor:MenloDcePortStats property: rxPauseCFCDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxPauseCFCDeltaMax
moClass: adaptor:MenloDcePortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
tcaAdaptorRxPauseCFCDeltaAvg
Fault Code: F34781
Message
Threshold Crossed: adaptor:MenloDcePortStats property: rxPauseCFCDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxPauseCFCDeltaAvg
moClass: adaptor:MenloDcePortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
tcaAdaptorRxPausePFCDelta
Fault Code: F34788
Message
Threshold Crossed: adaptor:MenloDcePortStats property: rxPausePFCDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxPausePFCDelta
moClass: adaptor:MenloDcePortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
tcaAdaptorRxPausePFCDeltaMin
Fault Code: F34789
Message
Threshold Crossed: adaptor:MenloDcePortStats property: rxPausePFCDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxPausePFCDeltaMin
moClass: adaptor:MenloDcePortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
tcaAdaptorRxPausePFCDeltaMax
Fault Code: F34790
Message
Threshold Crossed: adaptor:MenloDcePortStats property: rxPausePFCDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxPausePFCDeltaMax
moClass: adaptor:MenloDcePortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
tcaAdaptorRxPausePFCDeltaAvg
Fault Code: F34791
Message
Threshold Crossed: adaptor:MenloDcePortStats property: rxPausePFCDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxPausePFCDeltaAvg
moClass: adaptor:MenloDcePortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
tcaAdaptorTxPauseCFCDelta
Fault Code: F34798
Message
Threshold Crossed: adaptor:MenloDcePortStats property: txPauseCFCDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxPauseCFCDelta
moClass: adaptor:MenloDcePortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
tcaAdaptorTxPauseCFCDeltaMin
Fault Code: F34799
Message
Threshold Crossed: adaptor:MenloDcePortStats property: txPauseCFCDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxPauseCFCDeltaMin
moClass: adaptor:MenloDcePortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
tcaAdaptorTxPauseCFCDeltaMax
Fault Code: F34800
Message
Threshold Crossed: adaptor:MenloDcePortStats property: txPauseCFCDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxPauseCFCDeltaMax
moClass: adaptor:MenloDcePortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
tcaAdaptorTxPauseCFCDeltaAvg
Fault Code: F34801
Message
Threshold Crossed: adaptor:MenloDcePortStats property: txPauseCFCDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxPauseCFCDeltaAvg
moClass: adaptor:MenloDcePortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
tcaAdaptorTxPausePFCDelta
Fault Code: F34808
Message
Threshold Crossed: adaptor:MenloDcePortStats property: txPausePFCDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxPausePFCDelta
moClass: adaptor:MenloDcePortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
tcaAdaptorTxPausePFCDeltaMin
Fault Code: F34809
Message
Threshold Crossed: adaptor:MenloDcePortStats property: txPausePFCDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxPausePFCDeltaMin
moClass: adaptor:MenloDcePortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
tcaAdaptorTxPausePFCDeltaMax
Fault Code: F34810
Message
Threshold Crossed: adaptor:MenloDcePortStats property: txPausePFCDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxPausePFCDeltaMax
moClass: adaptor:MenloDcePortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
tcaAdaptorTxPausePFCDeltaAvg
Fault Code: F34811
Message
Threshold Crossed: adaptor:MenloDcePortStats property: txPausePFCDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxPausePFCDeltaAvg
moClass: adaptor:MenloDcePortStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/menlo-dce-port-stats-[menloPortIndex]
tcaAdaptorTxBytesDelta
Fault Code: F34822
Message
Threshold Crossed: adaptor:EtherIfStats property: txBytesDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxBytesDelta
moClass: adaptor:EtherIfStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
tcaAdaptorTxBytesDeltaMin
Fault Code: F34823
Message
Threshold Crossed: adaptor:EtherIfStats property: txBytesDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxBytesDeltaMin
moClass: adaptor:EtherIfStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
tcaAdaptorTxBytesDeltaMax
Fault Code: F34824
Message
Threshold Crossed: adaptor:EtherIfStats property: txBytesDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxBytesDeltaMax
moClass: adaptor:EtherIfStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
tcaAdaptorTxBytesDeltaAvg
Fault Code: F34825
Message
Threshold Crossed: adaptor:EtherIfStats property: txBytesDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxBytesDeltaAvg
moClass: adaptor:EtherIfStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
tcaAdaptorTxPacketsDelta
Fault Code: F34832
Message
Threshold Crossed: adaptor:EtherIfStats property: txPacketsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxPacketsDelta
moClass: adaptor:EtherIfStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
tcaAdaptorTxPacketsDeltaMin
Fault Code: F34833
Message
Threshold Crossed: adaptor:EtherIfStats property: txPacketsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxPacketsDeltaMin
moClass: adaptor:EtherIfStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
tcaAdaptorTxPacketsDeltaMax
Fault Code: F34834
Message
Threshold Crossed: adaptor:EtherIfStats property: txPacketsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxPacketsDeltaMax
moClass: adaptor:EtherIfStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
tcaAdaptorTxPacketsDeltaAvg
Fault Code: F34835
Message
Threshold Crossed: adaptor:EtherIfStats property: txPacketsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxPacketsDeltaAvg
moClass: adaptor:EtherIfStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
tcaAdaptorTxErrorsDelta
Fault Code: F34842
Message
Threshold Crossed: adaptor:EtherIfStats property: txErrorsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxErrorsDelta
moClass: adaptor:EtherIfStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
tcaAdaptorTxErrorsDeltaMin
Fault Code: F34843
Message
Threshold Crossed: adaptor:EtherIfStats property: txErrorsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxErrorsDeltaMin
moClass: adaptor:EtherIfStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
tcaAdaptorTxErrorsDeltaMax
Fault Code: F34844
Message
Threshold Crossed: adaptor:EtherIfStats property: txErrorsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxErrorsDeltaMax
moClass: adaptor:EtherIfStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
tcaAdaptorTxErrorsDeltaAvg
Fault Code: F34845
Message
Threshold Crossed: adaptor:EtherIfStats property: txErrorsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxErrorsDeltaAvg
moClass: adaptor:EtherIfStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
tcaAdaptorTxDroppedDelta
Fault Code: F34852
Message
Threshold Crossed: adaptor:EtherIfStats property: txDroppedDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxDroppedDelta
moClass: adaptor:EtherIfStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
tcaAdaptorTxDroppedDeltaMin
Fault Code: F34853
Message
Threshold Crossed: adaptor:EtherIfStats property: txDroppedDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxDroppedDeltaMin
moClass: adaptor:EtherIfStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
tcaAdaptorTxDroppedDeltaMax
Fault Code: F34854
Message
Threshold Crossed: adaptor:EtherIfStats property: txDroppedDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxDroppedDeltaMax
moClass: adaptor:EtherIfStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
tcaAdaptorTxDroppedDeltaAvg
Fault Code: F34855
Message
Threshold Crossed: adaptor:EtherIfStats property: txDroppedDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxDroppedDeltaAvg
moClass: adaptor:EtherIfStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
tcaAdaptorRxBytesDelta
Fault Code: F34862
Message
Threshold Crossed: adaptor:EtherIfStats property: rxBytesDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxBytesDelta
moClass: adaptor:EtherIfStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
tcaAdaptorRxBytesDeltaMin
Fault Code: F34863
Message
Threshold Crossed: adaptor:EtherIfStats property: rxBytesDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxBytesDeltaMin
moClass: adaptor:EtherIfStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
tcaAdaptorRxBytesDeltaMax
Fault Code: F34864
Message
Threshold Crossed: adaptor:EtherIfStats property: rxBytesDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxBytesDeltaMax
moClass: adaptor:EtherIfStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
tcaAdaptorRxBytesDeltaAvg
Fault Code: F34865
Message
Threshold Crossed: adaptor:EtherIfStats property: rxBytesDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxBytesDeltaAvg
moClass: adaptor:EtherIfStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
tcaAdaptorRxPacketsDelta
Fault Code: F34872
Message
Threshold Crossed: adaptor:EtherIfStats property: rxPacketsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxPacketsDelta
moClass: adaptor:EtherIfStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
tcaAdaptorRxPacketsDeltaMin
Fault Code: F34873
Message
Threshold Crossed: adaptor:EtherIfStats property: rxPacketsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxPacketsDeltaMin
moClass: adaptor:EtherIfStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
tcaAdaptorRxPacketsDeltaMax
Fault Code: F34874
Message
Threshold Crossed: adaptor:EtherIfStats property: rxPacketsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxPacketsDeltaMax
moClass: adaptor:EtherIfStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
tcaAdaptorRxPacketsDeltaAvg
Fault Code: F34875
Message
Threshold Crossed: adaptor:EtherIfStats property: rxPacketsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxPacketsDeltaAvg
moClass: adaptor:EtherIfStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
tcaAdaptorRxErrorsDelta
Fault Code: F34882
Message
Threshold Crossed: adaptor:EtherIfStats property: rxErrorsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxErrorsDelta
moClass: adaptor:EtherIfStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
tcaAdaptorRxErrorsDeltaMin
Fault Code: F34883
Message
Threshold Crossed: adaptor:EtherIfStats property: rxErrorsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxErrorsDeltaMin
moClass: adaptor:EtherIfStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
tcaAdaptorRxErrorsDeltaMax
Fault Code: F34884
Message
Threshold Crossed: adaptor:EtherIfStats property: rxErrorsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxErrorsDeltaMax
moClass: adaptor:EtherIfStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
tcaAdaptorRxErrorsDeltaAvg
Fault Code: F34885
Message
Threshold Crossed: adaptor:EtherIfStats property: rxErrorsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxErrorsDeltaAvg
moClass: adaptor:EtherIfStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
tcaAdaptorRxDroppedDelta
Fault Code: F34892
Message
Threshold Crossed: adaptor:EtherIfStats property: rxDroppedDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxDroppedDelta
moClass: adaptor:EtherIfStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
tcaAdaptorRxDroppedDeltaMin
Fault Code: F34893
Message
Threshold Crossed: adaptor:EtherIfStats property: rxDroppedDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxDroppedDeltaMin
moClass: adaptor:EtherIfStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
tcaAdaptorRxDroppedDeltaMax
Fault Code: F34894
Message
Threshold Crossed: adaptor:EtherIfStats property: rxDroppedDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxDroppedDeltaMax
moClass: adaptor:EtherIfStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
tcaAdaptorRxDroppedDeltaAvg
Fault Code: F34895
Message
Threshold Crossed: adaptor:EtherIfStats property: rxDroppedDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxDroppedDeltaAvg
moClass: adaptor:EtherIfStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]/vlan-[id]/ether-if-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vlan-[id]/ether-if-stats
tcaAdaptorTxFramesDelta
Fault Code: F34906
Message
Threshold Crossed: adaptor:FcIfFrameStats property: txFramesDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxFramesDelta
moClass: adaptor:FcIfFrameStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
tcaAdaptorTxFramesDeltaMin
Fault Code: F34907
Message
Threshold Crossed: adaptor:FcIfFrameStats property: txFramesDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxFramesDeltaMin
moClass: adaptor:FcIfFrameStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
tcaAdaptorTxFramesDeltaMax
Fault Code: F34908
Message
Threshold Crossed: adaptor:FcIfFrameStats property: txFramesDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxFramesDeltaMax
moClass: adaptor:FcIfFrameStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
tcaAdaptorTxFramesDeltaAvg
Fault Code: F34909
Message
Threshold Crossed: adaptor:FcIfFrameStats property: txFramesDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorTxFramesDeltaAvg
moClass: adaptor:FcIfFrameStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
tcaAdaptorRxFramesDelta
Fault Code: F34916
Message
Threshold Crossed: adaptor:FcIfFrameStats property: rxFramesDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxFramesDelta
moClass: adaptor:FcIfFrameStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
tcaAdaptorRxFramesDeltaMin
Fault Code: F34917
Message
Threshold Crossed: adaptor:FcIfFrameStats property: rxFramesDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxFramesDeltaMin
moClass: adaptor:FcIfFrameStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
tcaAdaptorRxFramesDeltaMax
Fault Code: F34918
Message
Threshold Crossed: adaptor:FcIfFrameStats property: rxFramesDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxFramesDeltaMax
moClass: adaptor:FcIfFrameStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
tcaAdaptorRxFramesDeltaAvg
Fault Code: F34919
Message
Threshold Crossed: adaptor:FcIfFrameStats property: rxFramesDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorRxFramesDeltaAvg
moClass: adaptor:FcIfFrameStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
tcaAdaptorErrorFramesDelta
Fault Code: F34926
Message
Threshold Crossed: adaptor:FcIfFrameStats property: errorFramesDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorErrorFramesDelta
moClass: adaptor:FcIfFrameStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
tcaAdaptorErrorFramesDeltaMin
Fault Code: F34927
Message
Threshold Crossed: adaptor:FcIfFrameStats property: errorFramesDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorErrorFramesDeltaMin
moClass: adaptor:FcIfFrameStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
tcaAdaptorErrorFramesDeltaMax
Fault Code: F34928
Message
Threshold Crossed: adaptor:FcIfFrameStats property: errorFramesDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorErrorFramesDeltaMax
moClass: adaptor:FcIfFrameStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
tcaAdaptorErrorFramesDeltaAvg
Fault Code: F34929
Message
Threshold Crossed: adaptor:FcIfFrameStats property: errorFramesDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorErrorFramesDeltaAvg
moClass: adaptor:FcIfFrameStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
tcaAdaptorDumpedFramesDelta
Fault Code: F34936
Message
Threshold Crossed: adaptor:FcIfFrameStats property: dumpedFramesDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDumpedFramesDelta
moClass: adaptor:FcIfFrameStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
tcaAdaptorDumpedFramesDeltaMin
Fault Code: F34937
Message
Threshold Crossed: adaptor:FcIfFrameStats property: dumpedFramesDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDumpedFramesDeltaMin
moClass: adaptor:FcIfFrameStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
tcaAdaptorDumpedFramesDeltaMax
Fault Code: F34938
Message
Threshold Crossed: adaptor:FcIfFrameStats property: dumpedFramesDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDumpedFramesDeltaMax
moClass: adaptor:FcIfFrameStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
tcaAdaptorDumpedFramesDeltaAvg
Fault Code: F34939
Message
Threshold Crossed: adaptor:FcIfFrameStats property: dumpedFramesDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorDumpedFramesDeltaAvg
moClass: adaptor:FcIfFrameStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-frame-stats
tcaAdaptorLipCountDelta
Fault Code: F34950
Message
Threshold Crossed: adaptor:FcIfEventStats property: lipCountDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLipCountDelta
moClass: adaptor:FcIfEventStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
tcaAdaptorLipCountDeltaMin
Fault Code: F34951
Message
Threshold Crossed: adaptor:FcIfEventStats property: lipCountDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLipCountDeltaMin
moClass: adaptor:FcIfEventStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
tcaAdaptorLipCountDeltaMax
Fault Code: F34952
Message
Threshold Crossed: adaptor:FcIfEventStats property: lipCountDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLipCountDeltaMax
moClass: adaptor:FcIfEventStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
tcaAdaptorLipCountDeltaAvg
Fault Code: F34953
Message
Threshold Crossed: adaptor:FcIfEventStats property: lipCountDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLipCountDeltaAvg
moClass: adaptor:FcIfEventStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
tcaAdaptorInvalidCRCCountDelta
Fault Code: F34960
Message
Threshold Crossed: adaptor:FcIfEventStats property: invalidCRCCountDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorInvalidCRCCountDelta
moClass: adaptor:FcIfEventStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
tcaAdaptorInvalidCRCCountDeltaMin
Fault Code: F34961
Message
Threshold Crossed: adaptor:FcIfEventStats property: invalidCRCCountDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorInvalidCRCCountDeltaMin
moClass: adaptor:FcIfEventStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
tcaAdaptorInvalidCRCCountDeltaMax
Fault Code: F34962
Message
Threshold Crossed: adaptor:FcIfEventStats property: invalidCRCCountDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorInvalidCRCCountDeltaMax
moClass: adaptor:FcIfEventStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
tcaAdaptorInvalidCRCCountDeltaAvg
Fault Code: F34963
Message
Threshold Crossed: adaptor:FcIfEventStats property: invalidCRCCountDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorInvalidCRCCountDeltaAvg
moClass: adaptor:FcIfEventStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
tcaAdaptorNOSCountDelta
Fault Code: F34970
Message
Threshold Crossed: adaptor:FcIfEventStats property: nOSCountDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorNOSCountDelta
moClass: adaptor:FcIfEventStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
tcaAdaptorNOSCountDeltaMin
Fault Code: F34971
Message
Threshold Crossed: adaptor:FcIfEventStats property: nOSCountDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorNOSCountDeltaMin
moClass: adaptor:FcIfEventStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
tcaAdaptorNOSCountDeltaMax
Fault Code: F34972
Message
Threshold Crossed: adaptor:FcIfEventStats property: nOSCountDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorNOSCountDeltaMax
moClass: adaptor:FcIfEventStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
tcaAdaptorNOSCountDeltaAvg
Fault Code: F34973
Message
Threshold Crossed: adaptor:FcIfEventStats property: nOSCountDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorNOSCountDeltaAvg
moClass: adaptor:FcIfEventStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
tcaAdaptorLinkFailureCountDelta
Fault Code: F34980
Message
Threshold Crossed: adaptor:FcIfEventStats property: linkFailureCountDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLinkFailureCountDelta
moClass: adaptor:FcIfEventStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
tcaAdaptorLinkFailureCountDeltaMin
Fault Code: F34981
Message
Threshold Crossed: adaptor:FcIfEventStats property: linkFailureCountDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLinkFailureCountDeltaMin
moClass: adaptor:FcIfEventStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
tcaAdaptorLinkFailureCountDeltaMax
Fault Code: F34982
Message
Threshold Crossed: adaptor:FcIfEventStats property: linkFailureCountDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLinkFailureCountDeltaMax
moClass: adaptor:FcIfEventStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
tcaAdaptorLinkFailureCountDeltaAvg
Fault Code: F34983
Message
Threshold Crossed: adaptor:FcIfEventStats property: linkFailureCountDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLinkFailureCountDeltaAvg
moClass: adaptor:FcIfEventStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
tcaAdaptorLossOfSyncCountDelta
Fault Code: F34990
Message
Threshold Crossed: adaptor:FcIfEventStats property: lossOfSyncCountDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLossOfSyncCountDelta
moClass: adaptor:FcIfEventStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
tcaAdaptorLossOfSyncCountDeltaMin
Fault Code: F34991
Message
Threshold Crossed: adaptor:FcIfEventStats property: lossOfSyncCountDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLossOfSyncCountDeltaMin
moClass: adaptor:FcIfEventStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
tcaAdaptorLossOfSyncCountDeltaMax
Fault Code: F34992
Message
Threshold Crossed: adaptor:FcIfEventStats property: lossOfSyncCountDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLossOfSyncCountDeltaMax
moClass: adaptor:FcIfEventStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
tcaAdaptorLossOfSyncCountDeltaAvg
Fault Code: F34993
Message
Threshold Crossed: adaptor:FcIfEventStats property: lossOfSyncCountDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLossOfSyncCountDeltaAvg
moClass: adaptor:FcIfEventStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
tcaAdaptorLossOfSignalCountDelta
Fault Code: F35000
Message
Threshold Crossed: adaptor:FcIfEventStats property: lossOfSignalCountDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLossOfSignalCountDelta
moClass: adaptor:FcIfEventStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
tcaAdaptorLossOfSignalCountDeltaMin
Fault Code: F35001
Message
Threshold Crossed: adaptor:FcIfEventStats property: lossOfSignalCountDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLossOfSignalCountDeltaMin
moClass: adaptor:FcIfEventStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
tcaAdaptorLossOfSignalCountDeltaMax
Fault Code: F35002
Message
Threshold Crossed: adaptor:FcIfEventStats property: lossOfSignalCountDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLossOfSignalCountDeltaMax
moClass: adaptor:FcIfEventStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
tcaAdaptorLossOfSignalCountDeltaAvg
Fault Code: F35003
Message
Threshold Crossed: adaptor:FcIfEventStats property: lossOfSignalCountDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorLossOfSignalCountDeltaAvg
moClass: adaptor:FcIfEventStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
tcaAdaptorSeqProtocolErrCountDelta
Fault Code: F35010
Message
Threshold Crossed: adaptor:FcIfEventStats property: seqProtocolErrCountDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorSeqProtocolErrCountDelta
moClass: adaptor:FcIfEventStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
tcaAdaptorSeqProtocolErrCountDeltaMin
Fault Code: F35011
Message
Threshold Crossed: adaptor:FcIfEventStats property: seqProtocolErrCountDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorSeqProtocolErrCountDeltaMin
moClass: adaptor:FcIfEventStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
tcaAdaptorSeqProtocolErrCountDeltaMax
Fault Code: F35012
Message
Threshold Crossed: adaptor:FcIfEventStats property: seqProtocolErrCountDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorSeqProtocolErrCountDeltaMax
moClass: adaptor:FcIfEventStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
tcaAdaptorSeqProtocolErrCountDeltaAvg
Fault Code: F35013
Message
Threshold Crossed: adaptor:FcIfEventStats property: seqProtocolErrCountDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorSeqProtocolErrCountDeltaAvg
moClass: adaptor:FcIfEventStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
tcaAdaptorSecondsSinceLastResetDelta
Fault Code: F35020
Message
Threshold Crossed: adaptor:FcIfEventStats property: secondsSinceLastResetDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorSecondsSinceLastResetDelta
moClass: adaptor:FcIfEventStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
tcaAdaptorSecondsSinceLastResetDeltaMin
Fault Code: F35021
Message
Threshold Crossed: adaptor:FcIfEventStats property: secondsSinceLastResetDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorSecondsSinceLastResetDeltaMin
moClass: adaptor:FcIfEventStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
tcaAdaptorSecondsSinceLastResetDeltaMax
Fault Code: F35022
Message
Threshold Crossed: adaptor:FcIfEventStats property: secondsSinceLastResetDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorSecondsSinceLastResetDeltaMax
moClass: adaptor:FcIfEventStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
tcaAdaptorSecondsSinceLastResetDeltaAvg
Fault Code: F35023
Message
Threshold Crossed: adaptor:FcIfEventStats property: secondsSinceLastResetDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorSecondsSinceLastResetDeltaAvg
moClass: adaptor:FcIfEventStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fc-if-event-stats
tcaSwMainBoardOutlet1
Fault Code: F35166
Message
Threshold Crossed: sw:EnvStats property: mainBoardOutlet1
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwMainBoardOutlet1
Affected MO: sys/switch-[id]/envstats
tcaSwMainBoardOutlet1Min
Fault Code: F35168
Message
Threshold Crossed: sw:EnvStats property: mainBoardOutlet1Min
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwMainBoardOutlet1Min
Affected MO: sys/switch-[id]/envstats
tcaSwMainBoardOutlet1Max
Fault Code: F35169
Message
Threshold Crossed: sw:EnvStats property: mainBoardOutlet1Max
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwMainBoardOutlet1Max
Affected MO: sys/switch-[id]/envstats
tcaSwMainBoardOutlet1Avg
Fault Code: F35170
Message
Threshold Crossed: sw:EnvStats property: mainBoardOutlet1Avg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwMainBoardOutlet1Avg
Affected MO: sys/switch-[id]/envstats
tcaSwMainBoardOutlet2
Fault Code: F35174
Message
Threshold Crossed: sw:EnvStats property: mainBoardOutlet2
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwMainBoardOutlet2
Affected MO: sys/switch-[id]/envstats
tcaSwMainBoardOutlet2Min
Fault Code: F35176
Message
Threshold Crossed: sw:EnvStats property: mainBoardOutlet2Min
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwMainBoardOutlet2Min
Affected MO: sys/switch-[id]/envstats
tcaSwMainBoardOutlet2Max
Fault Code: F35177
Message
Threshold Crossed: sw:EnvStats property: mainBoardOutlet2Max
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwMainBoardOutlet2Max
Affected MO: sys/switch-[id]/envstats
tcaSwMainBoardOutlet2Avg
Fault Code: F35178
Message
Threshold Crossed: sw:EnvStats property: mainBoardOutlet2Avg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwMainBoardOutlet2Avg
Affected MO: sys/switch-[id]/envstats
tcaSwFanCtrlrInlet1
Fault Code: F35198
Message
Threshold Crossed: sw:EnvStats property: fanCtrlrInlet1
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwFanCtrlrInlet1
Affected MO: sys/switch-[id]/envstats
tcaSwFanCtrlrInlet1Min
Fault Code: F35200
Message
Threshold Crossed: sw:EnvStats property: fanCtrlrInlet1Min
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwFanCtrlrInlet1Min
Affected MO: sys/switch-[id]/envstats
tcaSwFanCtrlrInlet1Max
Fault Code: F35201
Message
Threshold Crossed: sw:EnvStats property: fanCtrlrInlet1Max
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwFanCtrlrInlet1Max
Affected MO: sys/switch-[id]/envstats
tcaSwFanCtrlrInlet1Avg
Fault Code: F35202
Message
Threshold Crossed: sw:EnvStats property: fanCtrlrInlet1Avg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwFanCtrlrInlet1Avg
Affected MO: sys/switch-[id]/envstats
tcaSwFanCtrlrInlet2
Fault Code: F35206
Message
Threshold Crossed: sw:EnvStats property: fanCtrlrInlet2
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwFanCtrlrInlet2
Affected MO: sys/switch-[id]/envstats
tcaSwFanCtrlrInlet2Min
Fault Code: F35208
Message
Threshold Crossed: sw:EnvStats property: fanCtrlrInlet2Min
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwFanCtrlrInlet2Min
Affected MO: sys/switch-[id]/envstats
tcaSwFanCtrlrInlet2Max
Fault Code: F35209
Message
Threshold Crossed: sw:EnvStats property: fanCtrlrInlet2Max
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwFanCtrlrInlet2Max
Affected MO: sys/switch-[id]/envstats
tcaSwFanCtrlrInlet2Avg
Fault Code: F35210
Message
Threshold Crossed: sw:EnvStats property: fanCtrlrInlet2Avg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwFanCtrlrInlet2Avg
Affected MO: sys/switch-[id]/envstats
tcaSwFanCtrlrInlet3
Fault Code: F35214
Message
Threshold Crossed: sw:EnvStats property: fanCtrlrInlet3
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwFanCtrlrInlet3
Affected MO: sys/switch-[id]/envstats
tcaSwFanCtrlrInlet3Min
Fault Code: F35216
Message
Threshold Crossed: sw:EnvStats property: fanCtrlrInlet3Min
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwFanCtrlrInlet3Min
Affected MO: sys/switch-[id]/envstats
tcaSwFanCtrlrInlet3Max
Fault Code: F35217
Message
Threshold Crossed: sw:EnvStats property: fanCtrlrInlet3Max
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwFanCtrlrInlet3Max
Affected MO: sys/switch-[id]/envstats
tcaSwFanCtrlrInlet3Avg
Fault Code: F35218
Message
Threshold Crossed: sw:EnvStats property: fanCtrlrInlet3Avg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwFanCtrlrInlet3Avg
Affected MO: sys/switch-[id]/envstats
tcaSwFanCtrlrInlet4
Fault Code: F35222
Message
Threshold Crossed: sw:EnvStats property: fanCtrlrInlet4
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwFanCtrlrInlet4
Affected MO: sys/switch-[id]/envstats
tcaSwFanCtrlrInlet4Min
Fault Code: F35224
Message
Threshold Crossed: sw:EnvStats property: fanCtrlrInlet4Min
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwFanCtrlrInlet4Min
Affected MO: sys/switch-[id]/envstats
tcaSwFanCtrlrInlet4Max
Fault Code: F35225
Message
Threshold Crossed: sw:EnvStats property: fanCtrlrInlet4Max
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwFanCtrlrInlet4Max
Affected MO: sys/switch-[id]/envstats
tcaSwFanCtrlrInlet4Avg
Fault Code: F35226
Message
Threshold Crossed: sw:EnvStats property: fanCtrlrInlet4Avg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwFanCtrlrInlet4Avg
Affected MO: sys/switch-[id]/envstats
tcaSwMemAvailable
Fault Code: F35234
Message
Threshold Crossed: sw:SystemStats property: memAvailable
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwMemAvailable
Affected MO: sys/switch-[id]/sysstats
tcaSwMemAvailableMin
Fault Code: F35236
Message
Threshold Crossed: sw:SystemStats property: memAvailableMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwMemAvailableMin
Affected MO: sys/switch-[id]/sysstats
tcaSwMemAvailableMax
Fault Code: F35237
Message
Threshold Crossed: sw:SystemStats property: memAvailableMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwMemAvailableMax
Affected MO: sys/switch-[id]/sysstats
tcaSwMemAvailableAvg
Fault Code: F35238
Message
Threshold Crossed: sw:SystemStats property: memAvailableAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwMemAvailableAvg
Affected MO: sys/switch-[id]/sysstats
tcaSwMemCached
Fault Code: F35242
Message
Threshold Crossed: sw:SystemStats property: memCached
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwMemCached
Affected MO: sys/switch-[id]/sysstats
tcaSwMemCachedMin
Fault Code: F35244
Message
Threshold Crossed: sw:SystemStats property: memCachedMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwMemCachedMin
Affected MO: sys/switch-[id]/sysstats
tcaSwMemCachedMax
Fault Code: F35245
Message
Threshold Crossed: sw:SystemStats property: memCachedMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwMemCachedMax
Affected MO: sys/switch-[id]/sysstats
tcaSwMemCachedAvg
Fault Code: F35246
Message
Threshold Crossed: sw:SystemStats property: memCachedAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwMemCachedAvg
Affected MO: sys/switch-[id]/sysstats
tcaSwLoad
Fault Code: F35250
Message
Threshold Crossed: sw:SystemStats property: load
Explanation
Recommended Action
Fault Details
Affected MO: sys/switch-[id]/sysstats
tcaSwLoadMin
Fault Code: F35252
Message
Threshold Crossed: sw:SystemStats property: loadMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwLoadMin
Affected MO: sys/switch-[id]/sysstats
tcaSwLoadMax
Fault Code: F35253
Message
Threshold Crossed: sw:SystemStats property: loadMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwLoadMax
Affected MO: sys/switch-[id]/sysstats
tcaSwLoadAvg
Fault Code: F35254
Message
Threshold Crossed: sw:SystemStats property: loadAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwLoadAvg
Affected MO: sys/switch-[id]/sysstats
tcaEtherTotalBytesDelta
Fault Code: F35275
Message
Threshold Crossed: ether:TxStats property: totalBytesDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherTotalBytesDelta
Affected MO: fabric/eth-estc/[id]/pc-[portId]/tx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/tx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/tx-stats
tcaEtherTotalBytesDeltaMin
Fault Code: F35276
Message
Threshold Crossed: ether:TxStats property: totalBytesDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherTotalBytesDeltaMin
Affected MO: fabric/eth-estc/[id]/pc-[portId]/tx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/tx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/tx-stats
tcaEtherTotalBytesDeltaMax
Fault Code: F35277
Message
Threshold Crossed: ether:TxStats property: totalBytesDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherTotalBytesDeltaMax
Affected MO: fabric/eth-estc/[id]/pc-[portId]/tx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/tx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/tx-stats
tcaEtherTotalBytesDeltaAvg
Fault Code: F35278
Message
Threshold Crossed: ether:TxStats property: totalBytesDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherTotalBytesDeltaAvg
Affected MO: fabric/eth-estc/[id]/pc-[portId]/tx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/tx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/tx-stats
tcaEtherTotalPacketsDelta
Fault Code: F35285
Message
Threshold Crossed: ether:TxStats property: totalPacketsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherTotalPacketsDelta
Affected MO: fabric/eth-estc/[id]/pc-[portId]/tx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/tx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/tx-stats
tcaEtherTotalPacketsDeltaMin
Fault Code: F35286
Message
Threshold Crossed: ether:TxStats property: totalPacketsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherTotalPacketsDeltaMin
Affected MO: fabric/eth-estc/[id]/pc-[portId]/tx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/tx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/tx-stats
tcaEtherTotalPacketsDeltaMax
Fault Code: F35287
Message
Threshold Crossed: ether:TxStats property: totalPacketsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherTotalPacketsDeltaMax
Affected MO: fabric/eth-estc/[id]/pc-[portId]/tx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/tx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/tx-stats
tcaEtherTotalPacketsDeltaAvg
Fault Code: F35288
Message
Threshold Crossed: ether:TxStats property: totalPacketsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherTotalPacketsDeltaAvg
Affected MO: fabric/eth-estc/[id]/pc-[portId]/tx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/tx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/tx-stats
tcaEtherMulticastPacketsDelta
Fault Code: F35295
Message
Threshold Crossed: ether:TxStats property: multicastPacketsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherMulticastPacketsDelta
Affected MO: fabric/eth-estc/[id]/pc-[portId]/tx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/tx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/tx-stats
tcaEtherMulticastPacketsDeltaMin
Fault Code: F35296
Message
Threshold Crossed: ether:TxStats property: multicastPacketsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherMulticastPacketsDeltaMin
Affected MO: fabric/eth-estc/[id]/pc-[portId]/tx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/tx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/tx-stats
tcaEtherMulticastPacketsDeltaMax
Fault Code: F35297
Message
Threshold Crossed: ether:TxStats property: multicastPacketsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherMulticastPacketsDeltaMax
Affected MO: fabric/eth-estc/[id]/pc-[portId]/tx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/tx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/tx-stats
tcaEtherMulticastPacketsDeltaAvg
Fault Code: F35298
Message
Threshold Crossed: ether:TxStats property: multicastPacketsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherMulticastPacketsDeltaAvg
Affected MO: fabric/eth-estc/[id]/pc-[portId]/tx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/tx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/tx-stats
tcaEtherBroadcastPacketsDelta
Fault Code: F35305
Message
Threshold Crossed: ether:TxStats property: broadcastPacketsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherBroadcastPacketsDelta
Affected MO: fabric/eth-estc/[id]/pc-[portId]/tx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/tx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/tx-stats
tcaEtherBroadcastPacketsDeltaMin
Fault Code: F35306
Message
Threshold Crossed: ether:TxStats property: broadcastPacketsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherBroadcastPacketsDeltaMin
Affected MO: fabric/eth-estc/[id]/pc-[portId]/tx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/tx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/tx-stats
tcaEtherBroadcastPacketsDeltaMax
Fault Code: F35307
Message
Threshold Crossed: ether:TxStats property: broadcastPacketsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherBroadcastPacketsDeltaMax
Affected MO: fabric/eth-estc/[id]/pc-[portId]/tx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/tx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/tx-stats
tcaEtherBroadcastPacketsDeltaAvg
Fault Code: F35308
Message
Threshold Crossed: ether:TxStats property: broadcastPacketsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherBroadcastPacketsDeltaAvg
Affected MO: fabric/eth-estc/[id]/pc-[portId]/tx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/tx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/tx-stats
tcaEtherJumboPacketsDelta
Fault Code: F35315
Message
Threshold Crossed: ether:TxStats property: jumboPacketsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherJumboPacketsDelta
Affected MO: fabric/eth-estc/[id]/pc-[portId]/tx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/tx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/tx-stats
tcaEtherJumboPacketsDeltaMin
Fault Code: F35316
Message
Threshold Crossed: ether:TxStats property: jumboPacketsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherJumboPacketsDeltaMin
Affected MO: fabric/eth-estc/[id]/pc-[portId]/tx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/tx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/tx-stats
tcaEtherJumboPacketsDeltaMax
Fault Code: F35317
Message
Threshold Crossed: ether:TxStats property: jumboPacketsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherJumboPacketsDeltaMax
Affected MO: fabric/eth-estc/[id]/pc-[portId]/tx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/tx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/tx-stats
tcaEtherJumboPacketsDeltaAvg
Fault Code: F35318
Message
Threshold Crossed: ether:TxStats property: jumboPacketsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherJumboPacketsDeltaAvg
Affected MO: fabric/eth-estc/[id]/pc-[portId]/tx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/tx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/tx-stats
tcaEtherTotalBytesDelta
Fault Code: F35329
Message
Threshold Crossed: ether:RxStats property: totalBytesDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherTotalBytesDelta
Affected MO: fabric/eth-estc/[id]/pc-[portId]/rx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/rx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/rx-stats
tcaEtherTotalBytesDeltaMin
Fault Code: F35330
Message
Threshold Crossed: ether:RxStats property: totalBytesDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherTotalBytesDeltaMin
Affected MO: fabric/eth-estc/[id]/pc-[portId]/rx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/rx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/rx-stats
tcaEtherTotalBytesDeltaMax
Fault Code: F35331
Message
Threshold Crossed: ether:RxStats property: totalBytesDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherTotalBytesDeltaMax
Affected MO: fabric/eth-estc/[id]/pc-[portId]/rx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/rx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/rx-stats
tcaEtherTotalBytesDeltaAvg
Fault Code: F35332
Message
Threshold Crossed: ether:RxStats property: totalBytesDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherTotalBytesDeltaAvg
Affected MO: fabric/eth-estc/[id]/pc-[portId]/rx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/rx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/rx-stats
tcaEtherTotalPacketsDelta
Fault Code: F35339
Message
Threshold Crossed: ether:RxStats property: totalPacketsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherTotalPacketsDelta
Affected MO: fabric/eth-estc/[id]/pc-[portId]/rx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/rx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/rx-stats
tcaEtherTotalPacketsDeltaMin
Fault Code: F35340
Message
Threshold Crossed: ether:RxStats property: totalPacketsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherTotalPacketsDeltaMin
Affected MO: fabric/eth-estc/[id]/pc-[portId]/rx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/rx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/rx-stats
tcaEtherTotalPacketsDeltaMax
Fault Code: F35341
Message
Threshold Crossed: ether:RxStats property: totalPacketsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherTotalPacketsDeltaMax
Affected MO: fabric/eth-estc/[id]/pc-[portId]/rx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/rx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/rx-stats
tcaEtherTotalPacketsDeltaAvg
Fault Code: F35342
Message
Threshold Crossed: ether:RxStats property: totalPacketsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherTotalPacketsDeltaAvg
Affected MO: fabric/eth-estc/[id]/pc-[portId]/rx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/rx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/rx-stats
tcaEtherUnicastPacketsDelta
Fault Code: F35349
Message
Threshold Crossed: ether:RxStats property: unicastPacketsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherUnicastPacketsDelta
Affected MO: fabric/eth-estc/[id]/pc-[portId]/rx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/rx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/rx-stats
tcaEtherUnicastPacketsDeltaMin
Fault Code: F35350
Message
Threshold Crossed: ether:RxStats property: unicastPacketsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherUnicastPacketsDeltaMin
Affected MO: fabric/eth-estc/[id]/pc-[portId]/rx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/rx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/rx-stats
tcaEtherUnicastPacketsDeltaMax
Fault Code: F35351
Message
Threshold Crossed: ether:RxStats property: unicastPacketsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherUnicastPacketsDeltaMax
Affected MO: fabric/eth-estc/[id]/pc-[portId]/rx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/rx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/rx-stats
tcaEtherUnicastPacketsDeltaAvg
Fault Code: F35352
Message
Threshold Crossed: ether:RxStats property: unicastPacketsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherUnicastPacketsDeltaAvg
Affected MO: fabric/eth-estc/[id]/pc-[portId]/rx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/rx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/rx-stats
tcaEtherMulticastPacketsDelta
Fault Code: F35359
Message
Threshold Crossed: ether:RxStats property: multicastPacketsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherMulticastPacketsDelta
Affected MO: fabric/eth-estc/[id]/pc-[portId]/rx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/rx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/rx-stats
tcaEtherMulticastPacketsDeltaMin
Fault Code: F35360
Message
Threshold Crossed: ether:RxStats property: multicastPacketsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherMulticastPacketsDeltaMin
Affected MO: fabric/eth-estc/[id]/pc-[portId]/rx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/rx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/rx-stats
tcaEtherMulticastPacketsDeltaMax
Fault Code: F35361
Message
Threshold Crossed: ether:RxStats property: multicastPacketsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherMulticastPacketsDeltaMax
Affected MO: fabric/eth-estc/[id]/pc-[portId]/rx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/rx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/rx-stats
tcaEtherMulticastPacketsDeltaAvg
Fault Code: F35362
Message
Threshold Crossed: ether:RxStats property: multicastPacketsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherMulticastPacketsDeltaAvg
Affected MO: fabric/eth-estc/[id]/pc-[portId]/rx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/rx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/rx-stats
tcaEtherBroadcastPacketsDelta
Fault Code: F35369
Message
Threshold Crossed: ether:RxStats property: broadcastPacketsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherBroadcastPacketsDelta
Affected MO: fabric/eth-estc/[id]/pc-[portId]/rx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/rx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/rx-stats
tcaEtherBroadcastPacketsDeltaMin
Fault Code: F35370
Message
Threshold Crossed: ether:RxStats property: broadcastPacketsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherBroadcastPacketsDeltaMin
Affected MO: fabric/eth-estc/[id]/pc-[portId]/rx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/rx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/rx-stats
tcaEtherBroadcastPacketsDeltaMax
Fault Code: F35371
Message
Threshold Crossed: ether:RxStats property: broadcastPacketsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherBroadcastPacketsDeltaMax
Affected MO: fabric/eth-estc/[id]/pc-[portId]/rx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/rx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/rx-stats
tcaEtherBroadcastPacketsDeltaAvg
Fault Code: F35372
Message
Threshold Crossed: ether:RxStats property: broadcastPacketsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherBroadcastPacketsDeltaAvg
Affected MO: fabric/eth-estc/[id]/pc-[portId]/rx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/rx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/rx-stats
tcaEtherJumboPacketsDelta
Fault Code: F35379
Message
Threshold Crossed: ether:RxStats property: jumboPacketsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherJumboPacketsDelta
Affected MO: fabric/eth-estc/[id]/pc-[portId]/rx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/rx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/rx-stats
tcaEtherJumboPacketsDeltaMin
Fault Code: F35380
Message
Threshold Crossed: ether:RxStats property: jumboPacketsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherJumboPacketsDeltaMin
Affected MO: fabric/eth-estc/[id]/pc-[portId]/rx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/rx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/rx-stats
tcaEtherJumboPacketsDeltaMax
Fault Code: F35381
Message
Threshold Crossed: ether:RxStats property: jumboPacketsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherJumboPacketsDeltaMax
Affected MO: fabric/eth-estc/[id]/pc-[portId]/rx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/rx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/rx-stats
tcaEtherJumboPacketsDeltaAvg
Fault Code: F35382
Message
Threshold Crossed: ether:RxStats property: jumboPacketsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherJumboPacketsDeltaAvg
Affected MO: fabric/eth-estc/[id]/pc-[portId]/rx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/rx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/rx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/rx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/rx-stats
tcaComputeConsumedPower
Fault Code: F35962
Message
Threshold Crossed: compute:MbPowerStats property: consumedPower
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeConsumedPower
moClass: compute:MbPowerStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/power-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/power-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/power-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/power-stats
Affected MO: sys/rack-unit-[id]/board/power-stats
Affected MO: sys/rack-unit-[id]/ext-board-[id]/power-stats
tcaComputeConsumedPowerMin
Fault Code: F35964
Message
Threshold Crossed: compute:MbPowerStats property: consumedPowerMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeConsumedPowerMin
moClass: compute:MbPowerStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/power-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/power-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/power-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/power-stats
Affected MO: sys/rack-unit-[id]/board/power-stats
Affected MO: sys/rack-unit-[id]/ext-board-[id]/power-stats
tcaComputeConsumedPowerMax
Fault Code: F35965
Message
Threshold Crossed: compute:MbPowerStats property: consumedPowerMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeConsumedPowerMax
moClass: compute:MbPowerStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/power-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/power-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/power-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/power-stats
Affected MO: sys/rack-unit-[id]/board/power-stats
Affected MO: sys/rack-unit-[id]/ext-board-[id]/power-stats
tcaComputeConsumedPowerAvg
Fault Code: F35966
Message
Threshold Crossed: compute:MbPowerStats property: consumedPowerAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeConsumedPowerAvg
moClass: compute:MbPowerStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/power-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/power-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/power-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/power-stats
Affected MO: sys/rack-unit-[id]/board/power-stats
Affected MO: sys/rack-unit-[id]/ext-board-[id]/power-stats
tcaComputeFmTempSenIo
Fault Code: F35974
Message
Threshold Crossed: compute:MbTempStats property: fmTempSenIo
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeFmTempSenIo
moClass: compute:MbTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/temp-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/temp-stats
Affected MO: sys/rack-unit-[id]/board/temp-stats
Affected MO: sys/rack-unit-[id]/ext-board-[id]/temp-stats
tcaComputeFmTempSenIoMin
Fault Code: F35976
Message
Threshold Crossed: compute:MbTempStats property: fmTempSenIoMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeFmTempSenIoMin
moClass: compute:MbTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/temp-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/temp-stats
Affected MO: sys/rack-unit-[id]/board/temp-stats
Affected MO: sys/rack-unit-[id]/ext-board-[id]/temp-stats
tcaComputeFmTempSenIoMax
Fault Code: F35977
Message
Threshold Crossed: compute:MbTempStats property: fmTempSenIoMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeFmTempSenIoMax
moClass: compute:MbTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/temp-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/temp-stats
Affected MO: sys/rack-unit-[id]/board/temp-stats
Affected MO: sys/rack-unit-[id]/ext-board-[id]/temp-stats
tcaComputeFmTempSenIoAvg
Fault Code: F35978
Message
Threshold Crossed: compute:MbTempStats property: fmTempSenIoAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeFmTempSenIoAvg
moClass: compute:MbTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/temp-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/temp-stats
Affected MO: sys/rack-unit-[id]/board/temp-stats
Affected MO: sys/rack-unit-[id]/ext-board-[id]/temp-stats
tcaEquipmentInputPower
Fault Code: F36234
Message
Threshold Crossed: equipment:ChassisStats property: inputPower
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentInputPower
moClass: equipment:ChassisStats
Affected MO: sys/chassis-[id]/stats
tcaEquipmentInputPowerMin
Fault Code: F36236
Message
Threshold Crossed: equipment:ChassisStats property: inputPowerMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentInputPowerMin
moClass: equipment:ChassisStats
Affected MO: sys/chassis-[id]/stats
tcaEquipmentInputPowerMax
Fault Code: F36237
Message
Threshold Crossed: equipment:ChassisStats property: inputPowerMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentInputPowerMax
moClass: equipment:ChassisStats
Affected MO: sys/chassis-[id]/stats
tcaEquipmentInputPowerAvg
Fault Code: F36238
Message
Threshold Crossed: equipment:ChassisStats property: inputPowerAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentInputPowerAvg
moClass: equipment:ChassisStats
Affected MO: sys/chassis-[id]/stats
tcaEquipmentOutputPower
Fault Code: F36242
Message
Threshold Crossed: equipment:ChassisStats property: outputPower
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutputPower
moClass: equipment:ChassisStats
Affected MO: sys/chassis-[id]/stats
tcaEquipmentOutputPowerMin
Fault Code: F36244
Message
Threshold Crossed: equipment:ChassisStats property: outputPowerMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutputPowerMin
moClass: equipment:ChassisStats
Affected MO: sys/chassis-[id]/stats
tcaEquipmentOutputPowerMax
Fault Code: F36245
Message
Threshold Crossed: equipment:ChassisStats property: outputPowerMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutputPowerMax
moClass: equipment:ChassisStats
Affected MO: sys/chassis-[id]/stats
tcaEquipmentOutputPowerAvg
Fault Code: F36246
Message
Threshold Crossed: equipment:ChassisStats property: outputPowerAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutputPowerAvg
moClass: equipment:ChassisStats
Affected MO: sys/chassis-[id]/stats
tcaEquipmentAmbientTemp
Fault Code: F36266
Message
Threshold Crossed: equipment:PsuStats property: ambientTemp
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentAmbientTemp
moClass: equipment:PsuStats
Affected MO: sys/chassis-[id]/psu-[id]/stats
Affected MO: sys/fex-[id]/psu-[id]/stats
Affected MO: sys/rack-unit-[id]/psu-[id]/stats
Affected MO: sys/switch-[id]/psu-[id]/stats
tcaEquipmentAmbientTempMin
Fault Code: F36268
Message
Threshold Crossed: equipment:PsuStats property: ambientTempMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentAmbientTempMin
moClass: equipment:PsuStats
Affected MO: sys/chassis-[id]/psu-[id]/stats
Affected MO: sys/fex-[id]/psu-[id]/stats
Affected MO: sys/rack-unit-[id]/psu-[id]/stats
Affected MO: sys/switch-[id]/psu-[id]/stats
tcaEquipmentAmbientTempMax
Fault Code: F36269
Message
Threshold Crossed: equipment:PsuStats property: ambientTempMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentAmbientTempMax
moClass: equipment:PsuStats
Affected MO: sys/chassis-[id]/psu-[id]/stats
Affected MO: sys/fex-[id]/psu-[id]/stats
Affected MO: sys/rack-unit-[id]/psu-[id]/stats
Affected MO: sys/switch-[id]/psu-[id]/stats
tcaEquipmentAmbientTempAvg
Fault Code: F36270
Message
Threshold Crossed: equipment:PsuStats property: ambientTempAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentAmbientTempAvg
moClass: equipment:PsuStats
Affected MO: sys/chassis-[id]/psu-[id]/stats
Affected MO: sys/fex-[id]/psu-[id]/stats
Affected MO: sys/rack-unit-[id]/psu-[id]/stats
Affected MO: sys/switch-[id]/psu-[id]/stats
tcaEquipmentOutputCurrent
Fault Code: F36274
Message
Threshold Crossed: equipment:PsuStats property: outputCurrent
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutputCurrent
moClass: equipment:PsuStats
Affected MO: sys/chassis-[id]/psu-[id]/stats
Affected MO: sys/fex-[id]/psu-[id]/stats
Affected MO: sys/rack-unit-[id]/psu-[id]/stats
Affected MO: sys/switch-[id]/psu-[id]/stats
tcaEquipmentOutputCurrentMin
Fault Code: F36276
Message
Threshold Crossed: equipment:PsuStats property: outputCurrentMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutputCurrentMin
moClass: equipment:PsuStats
Affected MO: sys/chassis-[id]/psu-[id]/stats
Affected MO: sys/fex-[id]/psu-[id]/stats
Affected MO: sys/rack-unit-[id]/psu-[id]/stats
Affected MO: sys/switch-[id]/psu-[id]/stats
tcaEquipmentOutputCurrentMax
Fault Code: F36277
Message
Threshold Crossed: equipment:PsuStats property: outputCurrentMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutputCurrentMax
moClass: equipment:PsuStats
Affected MO: sys/chassis-[id]/psu-[id]/stats
Affected MO: sys/fex-[id]/psu-[id]/stats
Affected MO: sys/rack-unit-[id]/psu-[id]/stats
Affected MO: sys/switch-[id]/psu-[id]/stats
tcaEquipmentOutputCurrentAvg
Fault Code: F36278
Message
Threshold Crossed: equipment:PsuStats property: outputCurrentAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutputCurrentAvg
moClass: equipment:PsuStats
Affected MO: sys/chassis-[id]/psu-[id]/stats
Affected MO: sys/fex-[id]/psu-[id]/stats
Affected MO: sys/rack-unit-[id]/psu-[id]/stats
Affected MO: sys/switch-[id]/psu-[id]/stats
tcaEquipmentOutputPower
Fault Code: F36282
Message
Threshold Crossed: equipment:PsuStats property: outputPower
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutputPower
moClass: equipment:PsuStats
Affected MO: sys/chassis-[id]/psu-[id]/stats
Affected MO: sys/fex-[id]/psu-[id]/stats
Affected MO: sys/rack-unit-[id]/psu-[id]/stats
Affected MO: sys/switch-[id]/psu-[id]/stats
tcaEquipmentOutputPowerMin
Fault Code: F36284
Message
Threshold Crossed: equipment:PsuStats property: outputPowerMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutputPowerMin
moClass: equipment:PsuStats
Affected MO: sys/chassis-[id]/psu-[id]/stats
Affected MO: sys/fex-[id]/psu-[id]/stats
Affected MO: sys/rack-unit-[id]/psu-[id]/stats
Affected MO: sys/switch-[id]/psu-[id]/stats
tcaEquipmentOutputPowerMax
Fault Code: F36285
Message
Threshold Crossed: equipment:PsuStats property: outputPowerMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutputPowerMax
moClass: equipment:PsuStats
Affected MO: sys/chassis-[id]/psu-[id]/stats
Affected MO: sys/fex-[id]/psu-[id]/stats
Affected MO: sys/rack-unit-[id]/psu-[id]/stats
Affected MO: sys/switch-[id]/psu-[id]/stats
tcaEquipmentOutputPowerAvg
Fault Code: F36286
Message
Threshold Crossed: equipment:PsuStats property: outputPowerAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutputPowerAvg
moClass: equipment:PsuStats
Affected MO: sys/chassis-[id]/psu-[id]/stats
Affected MO: sys/fex-[id]/psu-[id]/stats
Affected MO: sys/rack-unit-[id]/psu-[id]/stats
Affected MO: sys/switch-[id]/psu-[id]/stats
tcaEquipmentCurrent
Fault Code: F36294
Message
Threshold Crossed: equipment:PsuInputStats property: current
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentCurrent
moClass: equipment:PsuInputStats
Affected MO: sys/chassis-[id]/psu-[id]/input-stats
Affected MO: sys/fex-[id]/psu-[id]/input-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/input-stats
Affected MO: sys/switch-[id]/psu-[id]/input-stats
tcaEquipmentCurrentMin
Fault Code: F36296
Message
Threshold Crossed: equipment:PsuInputStats property: currentMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentCurrentMin
moClass: equipment:PsuInputStats
Affected MO: sys/chassis-[id]/psu-[id]/input-stats
Affected MO: sys/fex-[id]/psu-[id]/input-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/input-stats
Affected MO: sys/switch-[id]/psu-[id]/input-stats
tcaEquipmentCurrentMax
Fault Code: F36297
Message
Threshold Crossed: equipment:PsuInputStats property: currentMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentCurrentMax
moClass: equipment:PsuInputStats
Affected MO: sys/chassis-[id]/psu-[id]/input-stats
Affected MO: sys/fex-[id]/psu-[id]/input-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/input-stats
Affected MO: sys/switch-[id]/psu-[id]/input-stats
tcaEquipmentCurrentAvg
Fault Code: F36298
Message
Threshold Crossed: equipment:PsuInputStats property: currentAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentCurrentAvg
moClass: equipment:PsuInputStats
Affected MO: sys/chassis-[id]/psu-[id]/input-stats
Affected MO: sys/fex-[id]/psu-[id]/input-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/input-stats
Affected MO: sys/switch-[id]/psu-[id]/input-stats
tcaEquipmentVoltage
Fault Code: F36302
Message
Threshold Crossed: equipment:PsuInputStats property: voltage
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentVoltage
moClass: equipment:PsuInputStats
Affected MO: sys/chassis-[id]/psu-[id]/input-stats
Affected MO: sys/fex-[id]/psu-[id]/input-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/input-stats
Affected MO: sys/switch-[id]/psu-[id]/input-stats
tcaEquipmentVoltageMin
Fault Code: F36304
Message
Threshold Crossed: equipment:PsuInputStats property: voltageMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentVoltageMin
moClass: equipment:PsuInputStats
Affected MO: sys/chassis-[id]/psu-[id]/input-stats
Affected MO: sys/fex-[id]/psu-[id]/input-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/input-stats
Affected MO: sys/switch-[id]/psu-[id]/input-stats
tcaEquipmentVoltageMax
Fault Code: F36305
Message
Threshold Crossed: equipment:PsuInputStats property: voltageMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentVoltageMax
moClass: equipment:PsuInputStats
Affected MO: sys/chassis-[id]/psu-[id]/input-stats
Affected MO: sys/fex-[id]/psu-[id]/input-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/input-stats
Affected MO: sys/switch-[id]/psu-[id]/input-stats
tcaEquipmentVoltageAvg
Fault Code: F36306
Message
Threshold Crossed: equipment:PsuInputStats property: voltageAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentVoltageAvg
moClass: equipment:PsuInputStats
Affected MO: sys/chassis-[id]/psu-[id]/input-stats
Affected MO: sys/fex-[id]/psu-[id]/input-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/input-stats
Affected MO: sys/switch-[id]/psu-[id]/input-stats
tcaEquipmentPower
Fault Code: F36310
Message
Threshold Crossed: equipment:PsuInputStats property: power
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentPower
moClass: equipment:PsuInputStats
Affected MO: sys/chassis-[id]/psu-[id]/input-stats
Affected MO: sys/fex-[id]/psu-[id]/input-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/input-stats
Affected MO: sys/switch-[id]/psu-[id]/input-stats
tcaEquipmentPowerMin
Fault Code: F36312
Message
Threshold Crossed: equipment:PsuInputStats property: powerMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentPowerMin
moClass: equipment:PsuInputStats
Affected MO: sys/chassis-[id]/psu-[id]/input-stats
Affected MO: sys/fex-[id]/psu-[id]/input-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/input-stats
Affected MO: sys/switch-[id]/psu-[id]/input-stats
tcaEquipmentPowerMax
Fault Code: F36313
Message
Threshold Crossed: equipment:PsuInputStats property: powerMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentPowerMax
moClass: equipment:PsuInputStats
Affected MO: sys/chassis-[id]/psu-[id]/input-stats
Affected MO: sys/fex-[id]/psu-[id]/input-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/input-stats
Affected MO: sys/switch-[id]/psu-[id]/input-stats
tcaEquipmentPowerAvg
Fault Code: F36314
Message
Threshold Crossed: equipment:PsuInputStats property: powerAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentPowerAvg
moClass: equipment:PsuInputStats
Affected MO: sys/chassis-[id]/psu-[id]/input-stats
Affected MO: sys/fex-[id]/psu-[id]/input-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/input-stats
Affected MO: sys/switch-[id]/psu-[id]/input-stats
tcaEquipmentAmbientTemp
Fault Code: F36323
Message
Threshold Crossed: equipment:FanModuleStats property: ambientTemp
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentAmbientTemp
moClass: equipment:FanModuleStats
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/stats
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/stats
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/stats
tcaEquipmentAmbientTempMin
Fault Code: F36325
Message
Threshold Crossed: equipment:FanModuleStats property: ambientTempMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentAmbientTempMin
moClass: equipment:FanModuleStats
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/stats
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/stats
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/stats
tcaEquipmentAmbientTempMax
Fault Code: F36326
Message
Threshold Crossed: equipment:FanModuleStats property: ambientTempMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentAmbientTempMax
moClass: equipment:FanModuleStats
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/stats
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/stats
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/stats
tcaEquipmentAmbientTempAvg
Fault Code: F36327
Message
Threshold Crossed: equipment:FanModuleStats property: ambientTempAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentAmbientTempAvg
moClass: equipment:FanModuleStats
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/stats
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/stats
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/stats
tcaEquipmentSpeed
Fault Code: F36335
Message
Threshold Crossed: equipment:FanStats property: speed
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentSpeed
moClass: equipment:FanStats
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]/stats
Affected MO: sys/fex-[id]/fan-[id]/stats
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]/stats
Affected MO: sys/switch-[id]/fan-[id]/stats
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]/stats
tcaEquipmentSpeedMin
Fault Code: F36337
Message
Threshold Crossed: equipment:FanStats property: speedMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentSpeedMin
moClass: equipment:FanStats
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]/stats
Affected MO: sys/fex-[id]/fan-[id]/stats
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]/stats
Affected MO: sys/switch-[id]/fan-[id]/stats
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]/stats
tcaEquipmentSpeedMax
Fault Code: F36338
Message
Threshold Crossed: equipment:FanStats property: speedMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentSpeedMax
moClass: equipment:FanStats
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]/stats
Affected MO: sys/fex-[id]/fan-[id]/stats
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]/stats
Affected MO: sys/switch-[id]/fan-[id]/stats
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]/stats
tcaEquipmentSpeedAvg
Fault Code: F36339
Message
Threshold Crossed: equipment:FanStats property: speedAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentSpeedAvg
moClass: equipment:FanStats
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]/stats
Affected MO: sys/fex-[id]/fan-[id]/stats
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]/stats
Affected MO: sys/switch-[id]/fan-[id]/stats
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]/stats
tcaEquipmentOutput12v
Fault Code: F37154
Message
Threshold Crossed: equipment:PsuStats property: output12v
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutput12v
moClass: equipment:PsuStats
Affected MO: sys/chassis-[id]/psu-[id]/stats
Affected MO: sys/fex-[id]/psu-[id]/stats
Affected MO: sys/rack-unit-[id]/psu-[id]/stats
Affected MO: sys/switch-[id]/psu-[id]/stats
tcaEquipmentOutput12vMin
Fault Code: F37156
Message
Threshold Crossed: equipment:PsuStats property: output12vMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutput12vMin
moClass: equipment:PsuStats
Affected MO: sys/chassis-[id]/psu-[id]/stats
Affected MO: sys/fex-[id]/psu-[id]/stats
Affected MO: sys/rack-unit-[id]/psu-[id]/stats
Affected MO: sys/switch-[id]/psu-[id]/stats
tcaEquipmentOutput12vMax
Fault Code: F37157
Message
Threshold Crossed: equipment:PsuStats property: output12vMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutput12vMax
moClass: equipment:PsuStats
Affected MO: sys/chassis-[id]/psu-[id]/stats
Affected MO: sys/fex-[id]/psu-[id]/stats
Affected MO: sys/rack-unit-[id]/psu-[id]/stats
Affected MO: sys/switch-[id]/psu-[id]/stats
tcaEquipmentOutput12vAvg
Fault Code: F37158
Message
Threshold Crossed: equipment:PsuStats property: output12vAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutput12vAvg
moClass: equipment:PsuStats
Affected MO: sys/chassis-[id]/psu-[id]/stats
Affected MO: sys/fex-[id]/psu-[id]/stats
Affected MO: sys/rack-unit-[id]/psu-[id]/stats
Affected MO: sys/switch-[id]/psu-[id]/stats
tcaEquipmentOutput3v3
Fault Code: F37162
Message
Threshold Crossed: equipment:PsuStats property: output3v3
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutput3v3
moClass: equipment:PsuStats
Affected MO: sys/chassis-[id]/psu-[id]/stats
Affected MO: sys/fex-[id]/psu-[id]/stats
Affected MO: sys/rack-unit-[id]/psu-[id]/stats
Affected MO: sys/switch-[id]/psu-[id]/stats
tcaEquipmentOutput3v3Min
Fault Code: F37164
Message
Threshold Crossed: equipment:PsuStats property: output3v3Min
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutput3v3Min
moClass: equipment:PsuStats
Affected MO: sys/chassis-[id]/psu-[id]/stats
Affected MO: sys/fex-[id]/psu-[id]/stats
Affected MO: sys/rack-unit-[id]/psu-[id]/stats
Affected MO: sys/switch-[id]/psu-[id]/stats
tcaEquipmentOutput3v3Max
Fault Code: F37165
Message
Threshold Crossed: equipment:PsuStats property: output3v3Max
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutput3v3Max
moClass: equipment:PsuStats
Affected MO: sys/chassis-[id]/psu-[id]/stats
Affected MO: sys/fex-[id]/psu-[id]/stats
Affected MO: sys/rack-unit-[id]/psu-[id]/stats
Affected MO: sys/switch-[id]/psu-[id]/stats
tcaEquipmentOutput3v3Avg
Fault Code: F37166
Message
Threshold Crossed: equipment:PsuStats property: output3v3Avg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutput3v3Avg
moClass: equipment:PsuStats
Affected MO: sys/chassis-[id]/psu-[id]/stats
Affected MO: sys/fex-[id]/psu-[id]/stats
Affected MO: sys/rack-unit-[id]/psu-[id]/stats
Affected MO: sys/switch-[id]/psu-[id]/stats
tcaEquipmentInput210v
Fault Code: F37170
Message
Threshold Crossed: equipment:PsuStats property: input210v
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentInput210v
moClass: equipment:PsuStats
Affected MO: sys/chassis-[id]/psu-[id]/stats
Affected MO: sys/fex-[id]/psu-[id]/stats
Affected MO: sys/rack-unit-[id]/psu-[id]/stats
Affected MO: sys/switch-[id]/psu-[id]/stats
tcaEquipmentInput210vMin
Fault Code: F37172
Message
Threshold Crossed: equipment:PsuStats property: input210vMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentInput210vMin
moClass: equipment:PsuStats
Affected MO: sys/chassis-[id]/psu-[id]/stats
Affected MO: sys/fex-[id]/psu-[id]/stats
Affected MO: sys/rack-unit-[id]/psu-[id]/stats
Affected MO: sys/switch-[id]/psu-[id]/stats
tcaEquipmentInput210vMax
Fault Code: F37173
Message
Threshold Crossed: equipment:PsuStats property: input210vMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentInput210vMax
moClass: equipment:PsuStats
Affected MO: sys/chassis-[id]/psu-[id]/stats
Affected MO: sys/fex-[id]/psu-[id]/stats
Affected MO: sys/rack-unit-[id]/psu-[id]/stats
Affected MO: sys/switch-[id]/psu-[id]/stats
tcaEquipmentInput210vAvg
Fault Code: F37174
Message
Threshold Crossed: equipment:PsuStats property: input210vAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentInput210vAvg
moClass: equipment:PsuStats
Affected MO: sys/chassis-[id]/psu-[id]/stats
Affected MO: sys/fex-[id]/psu-[id]/stats
Affected MO: sys/rack-unit-[id]/psu-[id]/stats
Affected MO: sys/switch-[id]/psu-[id]/stats
tcaEquipmentAmbientTemp
Fault Code: F37269
Message
Threshold Crossed: equipment:IOCardStats property: ambientTemp
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentAmbientTemp
moClass: equipment:IOCardStats
Affected MO: sys/chassis-[id]/slot-[id]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/stats
Affected MO: sys/fex-[id]/slot-[id]/stats
tcaEquipmentAmbientTempMin
Fault Code: F37271
Message
Threshold Crossed: equipment:IOCardStats property: ambientTempMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentAmbientTempMin
moClass: equipment:IOCardStats
Affected MO: sys/chassis-[id]/slot-[id]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/stats
Affected MO: sys/fex-[id]/slot-[id]/stats
tcaEquipmentAmbientTempMax
Fault Code: F37272
Message
Threshold Crossed: equipment:IOCardStats property: ambientTempMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentAmbientTempMax
moClass: equipment:IOCardStats
Affected MO: sys/chassis-[id]/slot-[id]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/stats
Affected MO: sys/fex-[id]/slot-[id]/stats
tcaEquipmentAmbientTempAvg
Fault Code: F37273
Message
Threshold Crossed: equipment:IOCardStats property: ambientTempAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentAmbientTempAvg
moClass: equipment:IOCardStats
Affected MO: sys/chassis-[id]/slot-[id]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/stats
Affected MO: sys/fex-[id]/slot-[id]/stats
tcaEtherAlignDelta
Fault Code: F37313
Message
Threshold Crossed: ether:ErrStats property: alignDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherAlignDelta
Affected MO: fabric/eth-estc/[id]/pc-[portId]/err-stats
Affected MO: fabric/lan/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaEtherAlignDeltaMin
Fault Code: F37314
Message
Threshold Crossed: ether:ErrStats property: alignDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherAlignDeltaMin
Affected MO: fabric/eth-estc/[id]/pc-[portId]/err-stats
Affected MO: fabric/lan/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaEtherAlignDeltaMax
Fault Code: F37315
Message
Threshold Crossed: ether:ErrStats property: alignDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherAlignDeltaMax
Affected MO: fabric/eth-estc/[id]/pc-[portId]/err-stats
Affected MO: fabric/lan/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaEtherAlignDeltaAvg
Fault Code: F37316
Message
Threshold Crossed: ether:ErrStats property: alignDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherAlignDeltaAvg
Affected MO: fabric/eth-estc/[id]/pc-[portId]/err-stats
Affected MO: fabric/lan/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaEtherFcsDelta
Fault Code: F37323
Message
Threshold Crossed: ether:ErrStats property: fcsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherFcsDelta
Affected MO: fabric/eth-estc/[id]/pc-[portId]/err-stats
Affected MO: fabric/lan/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaEtherFcsDeltaMin
Fault Code: F37324
Message
Threshold Crossed: ether:ErrStats property: fcsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherFcsDeltaMin
Affected MO: fabric/eth-estc/[id]/pc-[portId]/err-stats
Affected MO: fabric/lan/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaEtherFcsDeltaMax
Fault Code: F37325
Message
Threshold Crossed: ether:ErrStats property: fcsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherFcsDeltaMax
Affected MO: fabric/eth-estc/[id]/pc-[portId]/err-stats
Affected MO: fabric/lan/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaEtherFcsDeltaAvg
Fault Code: F37326
Message
Threshold Crossed: ether:ErrStats property: fcsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherFcsDeltaAvg
Affected MO: fabric/eth-estc/[id]/pc-[portId]/err-stats
Affected MO: fabric/lan/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaEtherXmitDelta
Fault Code: F37333
Message
Threshold Crossed: ether:ErrStats property: xmitDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherXmitDelta
Affected MO: fabric/eth-estc/[id]/pc-[portId]/err-stats
Affected MO: fabric/lan/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaEtherXmitDeltaMin
Fault Code: F37334
Message
Threshold Crossed: ether:ErrStats property: xmitDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherXmitDeltaMin
Affected MO: fabric/eth-estc/[id]/pc-[portId]/err-stats
Affected MO: fabric/lan/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaEtherXmitDeltaMax
Fault Code: F37335
Message
Threshold Crossed: ether:ErrStats property: xmitDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherXmitDeltaMax
Affected MO: fabric/eth-estc/[id]/pc-[portId]/err-stats
Affected MO: fabric/lan/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaEtherXmitDeltaAvg
Fault Code: F37336
Message
Threshold Crossed: ether:ErrStats property: xmitDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherXmitDeltaAvg
Affected MO: fabric/eth-estc/[id]/pc-[portId]/err-stats
Affected MO: fabric/lan/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaEtherRcvDelta
Fault Code: F37343
Message
Threshold Crossed: ether:ErrStats property: rcvDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherRcvDelta
Affected MO: fabric/eth-estc/[id]/pc-[portId]/err-stats
Affected MO: fabric/lan/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaEtherRcvDeltaMin
Fault Code: F37344
Message
Threshold Crossed: ether:ErrStats property: rcvDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherRcvDeltaMin
Affected MO: fabric/eth-estc/[id]/pc-[portId]/err-stats
Affected MO: fabric/lan/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaEtherRcvDeltaMax
Fault Code: F37345
Message
Threshold Crossed: ether:ErrStats property: rcvDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherRcvDeltaMax
Affected MO: fabric/eth-estc/[id]/pc-[portId]/err-stats
Affected MO: fabric/lan/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaEtherRcvDeltaAvg
Fault Code: F37346
Message
Threshold Crossed: ether:ErrStats property: rcvDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherRcvDeltaAvg
Affected MO: fabric/eth-estc/[id]/pc-[portId]/err-stats
Affected MO: fabric/lan/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaEtherUnderSizeDelta
Fault Code: F37353
Message
Threshold Crossed: ether:ErrStats property: underSizeDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherUnderSizeDelta
Affected MO: fabric/eth-estc/[id]/pc-[portId]/err-stats
Affected MO: fabric/lan/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaEtherUnderSizeDeltaMin
Fault Code: F37354
Message
Threshold Crossed: ether:ErrStats property: underSizeDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherUnderSizeDeltaMin
Affected MO: fabric/eth-estc/[id]/pc-[portId]/err-stats
Affected MO: fabric/lan/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaEtherUnderSizeDeltaMax
Fault Code: F37355
Message
Threshold Crossed: ether:ErrStats property: underSizeDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherUnderSizeDeltaMax
Affected MO: fabric/eth-estc/[id]/pc-[portId]/err-stats
Affected MO: fabric/lan/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaEtherUnderSizeDeltaAvg
Fault Code: F37356
Message
Threshold Crossed: ether:ErrStats property: underSizeDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherUnderSizeDeltaAvg
Affected MO: fabric/eth-estc/[id]/pc-[portId]/err-stats
Affected MO: fabric/lan/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaEtherOutDiscardDelta
Fault Code: F37363
Message
Threshold Crossed: ether:ErrStats property: outDiscardDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherOutDiscardDelta
Affected MO: fabric/eth-estc/[id]/pc-[portId]/err-stats
Affected MO: fabric/lan/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaEtherOutDiscardDeltaMin
Fault Code: F37364
Message
Threshold Crossed: ether:ErrStats property: outDiscardDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherOutDiscardDeltaMin
Affected MO: fabric/eth-estc/[id]/pc-[portId]/err-stats
Affected MO: fabric/lan/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaEtherOutDiscardDeltaMax
Fault Code: F37365
Message
Threshold Crossed: ether:ErrStats property: outDiscardDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherOutDiscardDeltaMax
Affected MO: fabric/eth-estc/[id]/pc-[portId]/err-stats
Affected MO: fabric/lan/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaEtherOutDiscardDeltaAvg
Fault Code: F37366
Message
Threshold Crossed: ether:ErrStats property: outDiscardDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherOutDiscardDeltaAvg
Affected MO: fabric/eth-estc/[id]/pc-[portId]/err-stats
Affected MO: fabric/lan/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaEtherIntMacTxDelta
Fault Code: F37383
Message
Threshold Crossed: ether:ErrStats property: intMacTxDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherIntMacTxDelta
Affected MO: fabric/eth-estc/[id]/pc-[portId]/err-stats
Affected MO: fabric/lan/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaEtherIntMacTxDeltaMin
Fault Code: F37384
Message
Threshold Crossed: ether:ErrStats property: intMacTxDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherIntMacTxDeltaMin
Affected MO: fabric/eth-estc/[id]/pc-[portId]/err-stats
Affected MO: fabric/lan/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaEtherIntMacTxDeltaMax
Fault Code: F37385
Message
Threshold Crossed: ether:ErrStats property: intMacTxDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherIntMacTxDeltaMax
Affected MO: fabric/eth-estc/[id]/pc-[portId]/err-stats
Affected MO: fabric/lan/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaEtherIntMacTxDeltaAvg
Fault Code: F37386
Message
Threshold Crossed: ether:ErrStats property: intMacTxDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherIntMacTxDeltaAvg
Affected MO: fabric/eth-estc/[id]/pc-[portId]/err-stats
Affected MO: fabric/lan/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaEtherIntMacRxDelta
Fault Code: F37393
Message
Threshold Crossed: ether:ErrStats property: intMacRxDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherIntMacRxDelta
Affected MO: fabric/eth-estc/[id]/pc-[portId]/err-stats
Affected MO: fabric/lan/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaEtherIntMacRxDeltaMin
Fault Code: F37394
Message
Threshold Crossed: ether:ErrStats property: intMacRxDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherIntMacRxDeltaMin
Affected MO: fabric/eth-estc/[id]/pc-[portId]/err-stats
Affected MO: fabric/lan/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaEtherIntMacRxDeltaMax
Fault Code: F37395
Message
Threshold Crossed: ether:ErrStats property: intMacRxDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherIntMacRxDeltaMax
Affected MO: fabric/eth-estc/[id]/pc-[portId]/err-stats
Affected MO: fabric/lan/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaEtherIntMacRxDeltaAvg
Fault Code: F37396
Message
Threshold Crossed: ether:ErrStats property: intMacRxDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherIntMacRxDeltaAvg
Affected MO: fabric/eth-estc/[id]/pc-[portId]/err-stats
Affected MO: fabric/lan/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaEtherSingleCollisionDelta
Fault Code: F37403
Message
Threshold Crossed: ether:LossStats property: singleCollisionDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherSingleCollisionDelta
Affected MO: fabric/eth-estc/[id]/pc-[portId]/loss-stats
Affected MO: fabric/lan/[id]/pc-[portId]/loss-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/loss-stats
tcaEtherSingleCollisionDeltaMin
Fault Code: F37404
Message
Threshold Crossed: ether:LossStats property: singleCollisionDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherSingleCollisionDeltaMin
Affected MO: fabric/eth-estc/[id]/pc-[portId]/loss-stats
Affected MO: fabric/lan/[id]/pc-[portId]/loss-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/loss-stats
tcaEtherSingleCollisionDeltaMax
Fault Code: F37405
Message
Threshold Crossed: ether:LossStats property: singleCollisionDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherSingleCollisionDeltaMax
Affected MO: fabric/eth-estc/[id]/pc-[portId]/loss-stats
Affected MO: fabric/lan/[id]/pc-[portId]/loss-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/loss-stats
tcaEtherSingleCollisionDeltaAvg
Fault Code: F37406
Message
Threshold Crossed: ether:LossStats property: singleCollisionDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherSingleCollisionDeltaAvg
Affected MO: fabric/eth-estc/[id]/pc-[portId]/loss-stats
Affected MO: fabric/lan/[id]/pc-[portId]/loss-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/loss-stats
tcaEtherMultiCollisionDelta
Fault Code: F37413
Message
Threshold Crossed: ether:LossStats property: multiCollisionDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherMultiCollisionDelta
Affected MO: fabric/eth-estc/[id]/pc-[portId]/loss-stats
Affected MO: fabric/lan/[id]/pc-[portId]/loss-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/loss-stats
tcaEtherMultiCollisionDeltaMin
Fault Code: F37414
Message
Threshold Crossed: ether:LossStats property: multiCollisionDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherMultiCollisionDeltaMin
Affected MO: fabric/eth-estc/[id]/pc-[portId]/loss-stats
Affected MO: fabric/lan/[id]/pc-[portId]/loss-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/loss-stats
tcaEtherMultiCollisionDeltaMax
Fault Code: F37415
Message
Threshold Crossed: ether:LossStats property: multiCollisionDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherMultiCollisionDeltaMax
Affected MO: fabric/eth-estc/[id]/pc-[portId]/loss-stats
Affected MO: fabric/lan/[id]/pc-[portId]/loss-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/loss-stats
tcaEtherMultiCollisionDeltaAvg
Fault Code: F37416
Message
Threshold Crossed: ether:LossStats property: multiCollisionDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherMultiCollisionDeltaAvg
Affected MO: fabric/eth-estc/[id]/pc-[portId]/loss-stats
Affected MO: fabric/lan/[id]/pc-[portId]/loss-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/loss-stats
tcaEtherLateCollisionDelta
Fault Code: F37423
Message
Threshold Crossed: ether:LossStats property: lateCollisionDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherLateCollisionDelta
Affected MO: fabric/eth-estc/[id]/pc-[portId]/loss-stats
Affected MO: fabric/lan/[id]/pc-[portId]/loss-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/loss-stats
tcaEtherLateCollisionDeltaMin
Fault Code: F37424
Message
Threshold Crossed: ether:LossStats property: lateCollisionDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherLateCollisionDeltaMin
Affected MO: fabric/eth-estc/[id]/pc-[portId]/loss-stats
Affected MO: fabric/lan/[id]/pc-[portId]/loss-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/loss-stats
tcaEtherLateCollisionDeltaMax
Fault Code: F37425
Message
Threshold Crossed: ether:LossStats property: lateCollisionDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherLateCollisionDeltaMax
Affected MO: fabric/eth-estc/[id]/pc-[portId]/loss-stats
Affected MO: fabric/lan/[id]/pc-[portId]/loss-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/loss-stats
tcaEtherLateCollisionDeltaAvg
Fault Code: F37426
Message
Threshold Crossed: ether:LossStats property: lateCollisionDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherLateCollisionDeltaAvg
Affected MO: fabric/eth-estc/[id]/pc-[portId]/loss-stats
Affected MO: fabric/lan/[id]/pc-[portId]/loss-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/loss-stats
tcaEtherCarrierSenseDelta
Fault Code: F37443
Message
Threshold Crossed: ether:LossStats property: carrierSenseDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherCarrierSenseDelta
Affected MO: fabric/eth-estc/[id]/pc-[portId]/loss-stats
Affected MO: fabric/lan/[id]/pc-[portId]/loss-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/loss-stats
tcaEtherCarrierSenseDeltaMin
Fault Code: F37444
Message
Threshold Crossed: ether:LossStats property: carrierSenseDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherCarrierSenseDeltaMin
Affected MO: fabric/eth-estc/[id]/pc-[portId]/loss-stats
Affected MO: fabric/lan/[id]/pc-[portId]/loss-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/loss-stats
tcaEtherCarrierSenseDeltaMax
Fault Code: F37445
Message
Threshold Crossed: ether:LossStats property: carrierSenseDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherCarrierSenseDeltaMax
Affected MO: fabric/eth-estc/[id]/pc-[portId]/loss-stats
Affected MO: fabric/lan/[id]/pc-[portId]/loss-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/loss-stats
tcaEtherCarrierSenseDeltaAvg
Fault Code: F37446
Message
Threshold Crossed: ether:LossStats property: carrierSenseDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherCarrierSenseDeltaAvg
Affected MO: fabric/eth-estc/[id]/pc-[portId]/loss-stats
Affected MO: fabric/lan/[id]/pc-[portId]/loss-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/loss-stats
tcaEtherGiantsDelta
Fault Code: F37453
Message
Threshold Crossed: ether:LossStats property: giantsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherGiantsDelta
Affected MO: fabric/eth-estc/[id]/pc-[portId]/loss-stats
Affected MO: fabric/lan/[id]/pc-[portId]/loss-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/loss-stats
tcaEtherGiantsDeltaMin
Fault Code: F37454
Message
Threshold Crossed: ether:LossStats property: giantsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherGiantsDeltaMin
Affected MO: fabric/eth-estc/[id]/pc-[portId]/loss-stats
Affected MO: fabric/lan/[id]/pc-[portId]/loss-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/loss-stats
tcaEtherGiantsDeltaMax
Fault Code: F37455
Message
Threshold Crossed: ether:LossStats property: giantsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherGiantsDeltaMax
Affected MO: fabric/eth-estc/[id]/pc-[portId]/loss-stats
Affected MO: fabric/lan/[id]/pc-[portId]/loss-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/loss-stats
tcaEtherGiantsDeltaAvg
Fault Code: F37456
Message
Threshold Crossed: ether:LossStats property: giantsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherGiantsDeltaAvg
Affected MO: fabric/eth-estc/[id]/pc-[portId]/loss-stats
Affected MO: fabric/lan/[id]/pc-[portId]/loss-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/loss-stats
tcaEtherSymbolDelta
Fault Code: F37463
Message
Threshold Crossed: ether:LossStats property: symbolDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherSymbolDelta
Affected MO: fabric/eth-estc/[id]/pc-[portId]/loss-stats
Affected MO: fabric/lan/[id]/pc-[portId]/loss-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/loss-stats
tcaEtherSymbolDeltaMin
Fault Code: F37464
Message
Threshold Crossed: ether:LossStats property: symbolDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherSymbolDeltaMin
Affected MO: fabric/eth-estc/[id]/pc-[portId]/loss-stats
Affected MO: fabric/lan/[id]/pc-[portId]/loss-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/loss-stats
tcaEtherSymbolDeltaMax
Fault Code: F37465
Message
Threshold Crossed: ether:LossStats property: symbolDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherSymbolDeltaMax
Affected MO: fabric/eth-estc/[id]/pc-[portId]/loss-stats
Affected MO: fabric/lan/[id]/pc-[portId]/loss-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/loss-stats
tcaEtherSymbolDeltaAvg
Fault Code: F37466
Message
Threshold Crossed: ether:LossStats property: symbolDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherSymbolDeltaAvg
Affected MO: fabric/eth-estc/[id]/pc-[portId]/loss-stats
Affected MO: fabric/lan/[id]/pc-[portId]/loss-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/loss-stats
tcaEtherSQETestDelta
Fault Code: F37473
Message
Threshold Crossed: ether:LossStats property: SQETestDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherSQETestDelta
Affected MO: fabric/eth-estc/[id]/pc-[portId]/loss-stats
Affected MO: fabric/lan/[id]/pc-[portId]/loss-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/loss-stats
tcaEtherSQETestDeltaMin
Fault Code: F37474
Message
Threshold Crossed: ether:LossStats property: SQETestDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherSQETestDeltaMin
Affected MO: fabric/eth-estc/[id]/pc-[portId]/loss-stats
Affected MO: fabric/lan/[id]/pc-[portId]/loss-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/loss-stats
tcaEtherSQETestDeltaMax
Fault Code: F37475
Message
Threshold Crossed: ether:LossStats property: SQETestDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherSQETestDeltaMax
Affected MO: fabric/eth-estc/[id]/pc-[portId]/loss-stats
Affected MO: fabric/lan/[id]/pc-[portId]/loss-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/loss-stats
tcaEtherSQETestDeltaAvg
Fault Code: F37476
Message
Threshold Crossed: ether:LossStats property: SQETestDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherSQETestDeltaAvg
Affected MO: fabric/eth-estc/[id]/pc-[portId]/loss-stats
Affected MO: fabric/lan/[id]/pc-[portId]/loss-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/loss-stats
tcaEtherRecvPauseDelta
Fault Code: F37485
Message
Threshold Crossed: ether:PauseStats property: recvPauseDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherRecvPauseDelta
moClass: ether:PauseStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/pause-stats
Affected MO: fabric/lan/[id]/pc-[portId]/pause-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/pause-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/pause-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/pause-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/pause-stats
tcaEtherRecvPauseDeltaMin
Fault Code: F37486
Message
Threshold Crossed: ether:PauseStats property: recvPauseDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherRecvPauseDeltaMin
moClass: ether:PauseStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/pause-stats
Affected MO: fabric/lan/[id]/pc-[portId]/pause-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/pause-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/pause-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/pause-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/pause-stats
tcaEtherRecvPauseDeltaMax
Fault Code: F37487
Message
Threshold Crossed: ether:PauseStats property: recvPauseDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherRecvPauseDeltaMax
moClass: ether:PauseStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/pause-stats
Affected MO: fabric/lan/[id]/pc-[portId]/pause-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/pause-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/pause-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/pause-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/pause-stats
tcaEtherRecvPauseDeltaAvg
Fault Code: F37488
Message
Threshold Crossed: ether:PauseStats property: recvPauseDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherRecvPauseDeltaAvg
moClass: ether:PauseStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/pause-stats
Affected MO: fabric/lan/[id]/pc-[portId]/pause-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/pause-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/pause-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/pause-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/pause-stats
tcaEtherXmitPauseDelta
Fault Code: F37495
Message
Threshold Crossed: ether:PauseStats property: xmitPauseDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherXmitPauseDelta
moClass: ether:PauseStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/pause-stats
Affected MO: fabric/lan/[id]/pc-[portId]/pause-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/pause-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/pause-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/pause-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/pause-stats
tcaEtherXmitPauseDeltaMin
Fault Code: F37496
Message
Threshold Crossed: ether:PauseStats property: xmitPauseDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherXmitPauseDeltaMin
moClass: ether:PauseStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/pause-stats
Affected MO: fabric/lan/[id]/pc-[portId]/pause-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/pause-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/pause-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/pause-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/pause-stats
tcaEtherXmitPauseDeltaMax
Fault Code: F37497
Message
Threshold Crossed: ether:PauseStats property: xmitPauseDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherXmitPauseDeltaMax
moClass: ether:PauseStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/pause-stats
Affected MO: fabric/lan/[id]/pc-[portId]/pause-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/pause-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/pause-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/pause-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/pause-stats
tcaEtherXmitPauseDeltaAvg
Fault Code: F37498
Message
Threshold Crossed: ether:PauseStats property: xmitPauseDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherXmitPauseDeltaAvg
moClass: ether:PauseStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/pause-stats
Affected MO: fabric/lan/[id]/pc-[portId]/pause-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/pause-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/pause-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/pause-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/pause-stats
tcaEtherResetsDelta
Fault Code: F37505
Message
Threshold Crossed: ether:PauseStats property: resetsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherResetsDelta
moClass: ether:PauseStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/pause-stats
Affected MO: fabric/lan/[id]/pc-[portId]/pause-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/pause-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/pause-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/pause-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/pause-stats
tcaEtherResetsDeltaMin
Fault Code: F37506
Message
Threshold Crossed: ether:PauseStats property: resetsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherResetsDeltaMin
moClass: ether:PauseStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/pause-stats
Affected MO: fabric/lan/[id]/pc-[portId]/pause-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/pause-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/pause-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/pause-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/pause-stats
tcaEtherResetsDeltaMax
Fault Code: F37507
Message
Threshold Crossed: ether:PauseStats property: resetsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherResetsDeltaMax
moClass: ether:PauseStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/pause-stats
Affected MO: fabric/lan/[id]/pc-[portId]/pause-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/pause-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/pause-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/pause-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/pause-stats
tcaEtherResetsDeltaAvg
Fault Code: F37508
Message
Threshold Crossed: ether:PauseStats property: resetsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherResetsDeltaAvg
moClass: ether:PauseStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/pause-stats
Affected MO: fabric/lan/[id]/pc-[portId]/pause-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/pause-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/pause-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/pause-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/pause-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/pause-stats
tcaEtherExcessCollisionDelta
Fault Code: F37532
Message
Threshold Crossed: ether:LossStats property: excessCollisionDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherExcessCollisionDelta
Affected MO: fabric/eth-estc/[id]/pc-[portId]/loss-stats
Affected MO: fabric/lan/[id]/pc-[portId]/loss-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/loss-stats
tcaEtherExcessCollisionDeltaMin
Fault Code: F37533
Message
Threshold Crossed: ether:LossStats property: excessCollisionDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherExcessCollisionDeltaMin
Affected MO: fabric/eth-estc/[id]/pc-[portId]/loss-stats
Affected MO: fabric/lan/[id]/pc-[portId]/loss-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/loss-stats
tcaEtherExcessCollisionDeltaMax
Fault Code: F37534
Message
Threshold Crossed: ether:LossStats property: excessCollisionDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherExcessCollisionDeltaMax
Affected MO: fabric/eth-estc/[id]/pc-[portId]/loss-stats
Affected MO: fabric/lan/[id]/pc-[portId]/loss-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/loss-stats
tcaEtherExcessCollisionDeltaAvg
Fault Code: F37535
Message
Threshold Crossed: ether:LossStats property: excessCollisionDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherExcessCollisionDeltaAvg
Affected MO: fabric/eth-estc/[id]/pc-[portId]/loss-stats
Affected MO: fabric/lan/[id]/pc-[portId]/loss-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/loss-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/loss-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/loss-stats
tcaEtherUnicastPacketsDelta
Fault Code: F37543
Message
Threshold Crossed: ether:TxStats property: unicastPacketsDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherUnicastPacketsDelta
Affected MO: fabric/eth-estc/[id]/pc-[portId]/tx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/tx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/tx-stats
tcaEtherUnicastPacketsDeltaMin
Fault Code: F37544
Message
Threshold Crossed: ether:TxStats property: unicastPacketsDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherUnicastPacketsDeltaMin
Affected MO: fabric/eth-estc/[id]/pc-[portId]/tx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/tx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/tx-stats
tcaEtherUnicastPacketsDeltaMax
Fault Code: F37545
Message
Threshold Crossed: ether:TxStats property: unicastPacketsDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherUnicastPacketsDeltaMax
Affected MO: fabric/eth-estc/[id]/pc-[portId]/tx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/tx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/tx-stats
tcaEtherUnicastPacketsDeltaAvg
Fault Code: F37546
Message
Threshold Crossed: ether:TxStats property: unicastPacketsDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherUnicastPacketsDeltaAvg
Affected MO: fabric/eth-estc/[id]/pc-[portId]/tx-stats
Affected MO: fabric/lan/[id]/pc-[portId]/tx-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/tx-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/tx-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/tx-stats
tcaEtherDeferredTxDelta
Fault Code: F37553
Message
Threshold Crossed: ether:ErrStats property: deferredTxDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherDeferredTxDelta
Affected MO: fabric/eth-estc/[id]/pc-[portId]/err-stats
Affected MO: fabric/lan/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaEtherDeferredTxDeltaMin
Fault Code: F37554
Message
Threshold Crossed: ether:ErrStats property: deferredTxDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherDeferredTxDeltaMin
Affected MO: fabric/eth-estc/[id]/pc-[portId]/err-stats
Affected MO: fabric/lan/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaEtherDeferredTxDeltaMax
Fault Code: F37555
Message
Threshold Crossed: ether:ErrStats property: deferredTxDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherDeferredTxDeltaMax
Affected MO: fabric/eth-estc/[id]/pc-[portId]/err-stats
Affected MO: fabric/lan/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaEtherDeferredTxDeltaAvg
Fault Code: F37556
Message
Threshold Crossed: ether:ErrStats property: deferredTxDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherDeferredTxDeltaAvg
Affected MO: fabric/eth-estc/[id]/pc-[portId]/err-stats
Affected MO: fabric/lan/[id]/pc-[portId]/err-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/err-stats
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/err-stats
tcaComputeInputVoltage
Fault Code: F37564
Message
Threshold Crossed: compute:MbPowerStats property: inputVoltage
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeInputVoltage
moClass: compute:MbPowerStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/power-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/power-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/power-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/power-stats
Affected MO: sys/rack-unit-[id]/board/power-stats
Affected MO: sys/rack-unit-[id]/ext-board-[id]/power-stats
tcaComputeInputVoltageMin
Fault Code: F37566
Message
Threshold Crossed: compute:MbPowerStats property: inputVoltageMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeInputVoltageMin
moClass: compute:MbPowerStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/power-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/power-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/power-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/power-stats
Affected MO: sys/rack-unit-[id]/board/power-stats
Affected MO: sys/rack-unit-[id]/ext-board-[id]/power-stats
tcaComputeInputVoltageMax
Fault Code: F37567
Message
Threshold Crossed: compute:MbPowerStats property: inputVoltageMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeInputVoltageMax
moClass: compute:MbPowerStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/power-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/power-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/power-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/power-stats
Affected MO: sys/rack-unit-[id]/board/power-stats
Affected MO: sys/rack-unit-[id]/ext-board-[id]/power-stats
tcaComputeInputVoltageAvg
Fault Code: F37568
Message
Threshold Crossed: compute:MbPowerStats property: inputVoltageAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeInputVoltageAvg
moClass: compute:MbPowerStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/power-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/power-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/power-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/power-stats
Affected MO: sys/rack-unit-[id]/board/power-stats
Affected MO: sys/rack-unit-[id]/ext-board-[id]/power-stats
tcaComputeInputCurrent
Fault Code: F37572
Message
Threshold Crossed: compute:MbPowerStats property: inputCurrent
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeInputCurrent
moClass: compute:MbPowerStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/power-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/power-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/power-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/power-stats
Affected MO: sys/rack-unit-[id]/board/power-stats
Affected MO: sys/rack-unit-[id]/ext-board-[id]/power-stats
tcaComputeInputCurrentMin
Fault Code: F37574
Message
Threshold Crossed: compute:MbPowerStats property: inputCurrentMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeInputCurrentMin
moClass: compute:MbPowerStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/power-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/power-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/power-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/power-stats
Affected MO: sys/rack-unit-[id]/board/power-stats
Affected MO: sys/rack-unit-[id]/ext-board-[id]/power-stats
tcaComputeInputCurrentMax
Fault Code: F37575
Message
Threshold Crossed: compute:MbPowerStats property: inputCurrentMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeInputCurrentMax
moClass: compute:MbPowerStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/power-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/power-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/power-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/power-stats
Affected MO: sys/rack-unit-[id]/board/power-stats
Affected MO: sys/rack-unit-[id]/ext-board-[id]/power-stats
tcaComputeInputCurrentAvg
Fault Code: F37576
Message
Threshold Crossed: compute:MbPowerStats property: inputCurrentAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeInputCurrentAvg
moClass: compute:MbPowerStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/power-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/power-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/power-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/power-stats
Affected MO: sys/rack-unit-[id]/board/power-stats
Affected MO: sys/rack-unit-[id]/ext-board-[id]/power-stats
tcaComputeFmTempSenRear
Fault Code: F37580
Message
Threshold Crossed: compute:MbTempStats property: fmTempSenRear
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeFmTempSenRear
moClass: compute:MbTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/temp-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/temp-stats
Affected MO: sys/rack-unit-[id]/board/temp-stats
Affected MO: sys/rack-unit-[id]/ext-board-[id]/temp-stats
tcaComputeFmTempSenRearMin
Fault Code: F37582
Message
Threshold Crossed: compute:MbTempStats property: fmTempSenRearMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeFmTempSenRearMin
moClass: compute:MbTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/temp-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/temp-stats
Affected MO: sys/rack-unit-[id]/board/temp-stats
Affected MO: sys/rack-unit-[id]/ext-board-[id]/temp-stats
tcaComputeFmTempSenRearMax
Fault Code: F37583
Message
Threshold Crossed: compute:MbTempStats property: fmTempSenRearMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeFmTempSenRearMax
moClass: compute:MbTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/temp-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/temp-stats
Affected MO: sys/rack-unit-[id]/board/temp-stats
Affected MO: sys/rack-unit-[id]/ext-board-[id]/temp-stats
tcaComputeFmTempSenRearAvg
Fault Code: F37584
Message
Threshold Crossed: compute:MbTempStats property: fmTempSenRearAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeFmTempSenRearAvg
moClass: compute:MbTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/temp-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/temp-stats
Affected MO: sys/rack-unit-[id]/board/temp-stats
Affected MO: sys/rack-unit-[id]/ext-board-[id]/temp-stats
tcaMemoryTemperature
Fault Code: F37600
Message
Threshold Crossed: memory:UnitEnvStats property: temperature
Explanation
Recommended Action
Fault Details
mibFaultName: tcaMemoryTemperature
moClass: memory:UnitEnvStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]/mem-[id]/dimm-env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/memarray-[id]/mem-[id]/dimm-env-stats
Affected MO: sys/rack-unit-[id]/board/memarray-[id]/mem-[id]/dimm-env-stats
tcaMemoryTemperatureMin
Fault Code: F37602
Message
Threshold Crossed: memory:UnitEnvStats property: temperatureMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaMemoryTemperatureMin
moClass: memory:UnitEnvStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]/mem-[id]/dimm-env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/memarray-[id]/mem-[id]/dimm-env-stats
Affected MO: sys/rack-unit-[id]/board/memarray-[id]/mem-[id]/dimm-env-stats
tcaMemoryTemperatureMax
Fault Code: F37603
Message
Threshold Crossed: memory:UnitEnvStats property: temperatureMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaMemoryTemperatureMax
moClass: memory:UnitEnvStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]/mem-[id]/dimm-env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/memarray-[id]/mem-[id]/dimm-env-stats
Affected MO: sys/rack-unit-[id]/board/memarray-[id]/mem-[id]/dimm-env-stats
tcaMemoryTemperatureAvg
Fault Code: F37604
Message
Threshold Crossed: memory:UnitEnvStats property: temperatureAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaMemoryTemperatureAvg
moClass: memory:UnitEnvStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]/mem-[id]/dimm-env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/memarray-[id]/mem-[id]/dimm-env-stats
Affected MO: sys/rack-unit-[id]/board/memarray-[id]/mem-[id]/dimm-env-stats
tcaProcessorTemperature
Fault Code: F37610
Message
Threshold Crossed: processor:EnvStats property: temperature
Explanation
Recommended Action
Fault Details
mibFaultName: tcaProcessorTemperature
moClass: processor:EnvStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]/env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/cpu-[id]/env-stats
Affected MO: sys/rack-unit-[id]/board/cpu-[id]/env-stats
tcaProcessorTemperatureMin
Fault Code: F37612
Message
Threshold Crossed: processor:EnvStats property: temperatureMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaProcessorTemperatureMin
moClass: processor:EnvStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]/env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/cpu-[id]/env-stats
Affected MO: sys/rack-unit-[id]/board/cpu-[id]/env-stats
tcaProcessorTemperatureMax
Fault Code: F37613
Message
Threshold Crossed: processor:EnvStats property: temperatureMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaProcessorTemperatureMax
moClass: processor:EnvStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]/env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/cpu-[id]/env-stats
Affected MO: sys/rack-unit-[id]/board/cpu-[id]/env-stats
tcaProcessorTemperatureAvg
Fault Code: F37614
Message
Threshold Crossed: processor:EnvStats property: temperatureAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaProcessorTemperatureAvg
moClass: processor:EnvStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]/env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/cpu-[id]/env-stats
Affected MO: sys/rack-unit-[id]/board/cpu-[id]/env-stats
tcaSwPsuCtrlrInlet1
Fault Code: F37771
Message
Threshold Crossed: sw:EnvStats property: psuCtrlrInlet1
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwPsuCtrlrInlet1
Affected MO: sys/switch-[id]/envstats
tcaSwPsuCtrlrInlet1Min
Fault Code: F37773
Message
Threshold Crossed: sw:EnvStats property: psuCtrlrInlet1Min
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwPsuCtrlrInlet1Min
Affected MO: sys/switch-[id]/envstats
tcaSwPsuCtrlrInlet1Max
Fault Code: F37774
Message
Threshold Crossed: sw:EnvStats property: psuCtrlrInlet1Max
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwPsuCtrlrInlet1Max
Affected MO: sys/switch-[id]/envstats
tcaSwPsuCtrlrInlet1Avg
Fault Code: F37775
Message
Threshold Crossed: sw:EnvStats property: psuCtrlrInlet1Avg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwPsuCtrlrInlet1Avg
Affected MO: sys/switch-[id]/envstats
tcaSwPsuCtrlrInlet2
Fault Code: F37779
Message
Threshold Crossed: sw:EnvStats property: psuCtrlrInlet2
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwPsuCtrlrInlet2
Affected MO: sys/switch-[id]/envstats
tcaSwPsuCtrlrInlet2Min
Fault Code: F37781
Message
Threshold Crossed: sw:EnvStats property: psuCtrlrInlet2Min
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwPsuCtrlrInlet2Min
Affected MO: sys/switch-[id]/envstats
tcaSwPsuCtrlrInlet2Max
Fault Code: F37782
Message
Threshold Crossed: sw:EnvStats property: psuCtrlrInlet2Max
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwPsuCtrlrInlet2Max
Affected MO: sys/switch-[id]/envstats
tcaSwPsuCtrlrInlet2Avg
Fault Code: F37783
Message
Threshold Crossed: sw:EnvStats property: psuCtrlrInlet2Avg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwPsuCtrlrInlet2Avg
Affected MO: sys/switch-[id]/envstats
tcaComputeDllpErrors
Fault Code: F38022
Message
Threshold Crossed: compute:PCIeFatalProtocolStats property: dllpErrors
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeDllpErrors
moClass: compute:PCIeFatalProtocolStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/pciefat-protocol-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/pciefat-protocol-stats
Affected MO: sys/rack-unit-[id]/board/pciefat-protocol-stats
tcaComputeFlowControlErrors
Fault Code: F38032
Message
Threshold Crossed: compute:PCIeFatalProtocolStats property: flowControlErrors
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeFlowControlErrors
moClass: compute:PCIeFatalProtocolStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/pciefat-protocol-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/pciefat-protocol-stats
Affected MO: sys/rack-unit-[id]/board/pciefat-protocol-stats
tcaComputeUnsupportedRequestErrors
Fault Code: F38044
Message
Threshold Crossed: compute:PCIeFatalReceiveStats property: unsupportedRequestErrors
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeUnsupportedRequestErrors
moClass: compute:PCIeFatalReceiveStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/pciefat-receive-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/pciefat-receive-stats
Affected MO: sys/rack-unit-[id]/board/pciefat-receive-stats
tcaComputeErrFatalErrors
Fault Code: F38054
Message
Threshold Crossed: compute:PCIeFatalReceiveStats property: errFatalErrors
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeErrFatalErrors
moClass: compute:PCIeFatalReceiveStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/pciefat-receive-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/pciefat-receive-stats
Affected MO: sys/rack-unit-[id]/board/pciefat-receive-stats
tcaComputeErrNonFatalErrors
Fault Code: F38064
Message
Threshold Crossed: compute:PCIeFatalReceiveStats property: errNonFatalErrors
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeErrNonFatalErrors
moClass: compute:PCIeFatalReceiveStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/pciefat-receive-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/pciefat-receive-stats
Affected MO: sys/rack-unit-[id]/board/pciefat-receive-stats
tcaComputeUnexpectedErrors
Fault Code: F38086
Message
Threshold Crossed: compute:PCIeFatalCompletionStats property: unexpectedErrors
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeUnexpectedErrors
moClass: compute:PCIeFatalCompletionStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/pciefat-completion-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/pciefat-completion-stats
Affected MO: sys/rack-unit-[id]/board/pciefat-completion-stats
tcaComputeTimeoutErrors
Fault Code: F38096
Message
Threshold Crossed: compute:PCIeFatalCompletionStats property: TimeoutErrors
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeTimeoutErrors
moClass: compute:PCIeFatalCompletionStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/pciefat-completion-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/pciefat-completion-stats
Affected MO: sys/rack-unit-[id]/board/pciefat-completion-stats
tcaComputeAbortErrors
Fault Code: F38106
Message
Threshold Crossed: compute:PCIeFatalCompletionStats property: AbortErrors
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeAbortErrors
moClass: compute:PCIeFatalCompletionStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/pciefat-completion-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/pciefat-completion-stats
Affected MO: sys/rack-unit-[id]/board/pciefat-completion-stats
tcaComputeSurpriseLinkDownErrors
Fault Code: F38128
Message
Threshold Crossed: compute:PCIeFatalStats property: surpriseLinkDownErrors
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeSurpriseLinkDownErrors
moClass: compute:PCIeFatalStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/pciefat-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/pciefat-stats
Affected MO: sys/rack-unit-[id]/board/pciefat-stats
tcaComputePoisonedTLPErrors
Fault Code: F38138
Message
Threshold Crossed: compute:PCIeFatalStats property: poisonedTLPErrors
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputePoisonedTLPErrors
moClass: compute:PCIeFatalStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/pciefat-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/pciefat-stats
Affected MO: sys/rack-unit-[id]/board/pciefat-stats
tcaComputeAcsViolationErrors
Fault Code: F38148
Message
Threshold Crossed: compute:PCIeFatalStats property: acsViolationErrors
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeAcsViolationErrors
moClass: compute:PCIeFatalStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/pciefat-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/pciefat-stats
Affected MO: sys/rack-unit-[id]/board/pciefat-stats
tcaComputeMalformedTLPErrors
Fault Code: F38158
Message
Threshold Crossed: compute:PCIeFatalStats property: malformedTLPErrors
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeMalformedTLPErrors
moClass: compute:PCIeFatalStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/pciefat-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/pciefat-stats
Affected MO: sys/rack-unit-[id]/board/pciefat-stats
tcaEquipmentTemp
Fault Code: F38311
Message
Threshold Crossed: equipment:IOCardStats property: temp
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentTemp
moClass: equipment:IOCardStats
Affected MO: sys/chassis-[id]/slot-[id]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/stats
Affected MO: sys/fex-[id]/slot-[id]/stats
tcaEquipmentTempMin
Fault Code: F38313
Message
Threshold Crossed: equipment:IOCardStats property: tempMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentTempMin
moClass: equipment:IOCardStats
Affected MO: sys/chassis-[id]/slot-[id]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/stats
Affected MO: sys/fex-[id]/slot-[id]/stats
tcaEquipmentTempMax
Fault Code: F38314
Message
Threshold Crossed: equipment:IOCardStats property: tempMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentTempMax
moClass: equipment:IOCardStats
Affected MO: sys/chassis-[id]/slot-[id]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/stats
Affected MO: sys/fex-[id]/slot-[id]/stats
tcaEquipmentTempAvg
Fault Code: F38315
Message
Threshold Crossed: equipment:IOCardStats property: tempAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentTempAvg
moClass: equipment:IOCardStats
Affected MO: sys/chassis-[id]/slot-[id]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/stats
Affected MO: sys/fex-[id]/slot-[id]/stats
tcaProcessorInputCurrent
Fault Code: F38349
Message
Threshold Crossed: processor:EnvStats property: inputCurrent
Explanation
Recommended Action
Fault Details
mibFaultName: tcaProcessorInputCurrent
moClass: processor:EnvStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]/env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/cpu-[id]/env-stats
Affected MO: sys/rack-unit-[id]/board/cpu-[id]/env-stats
tcaProcessorInputCurrentMin
Fault Code: F38351
Message
Threshold Crossed: processor:EnvStats property: inputCurrentMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaProcessorInputCurrentMin
moClass: processor:EnvStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]/env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/cpu-[id]/env-stats
Affected MO: sys/rack-unit-[id]/board/cpu-[id]/env-stats
tcaProcessorInputCurrentMax
Fault Code: F38352
Message
Threshold Crossed: processor:EnvStats property: inputCurrentMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaProcessorInputCurrentMax
moClass: processor:EnvStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]/env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/cpu-[id]/env-stats
Affected MO: sys/rack-unit-[id]/board/cpu-[id]/env-stats
tcaProcessorInputCurrentAvg
Fault Code: F38353
Message
Threshold Crossed: processor:EnvStats property: inputCurrentAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaProcessorInputCurrentAvg
moClass: processor:EnvStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]/env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/cpu-[id]/env-stats
Affected MO: sys/rack-unit-[id]/board/cpu-[id]/env-stats
tcaMemoryInputCurrent
Fault Code: F38357
Message
Threshold Crossed: memory:ArrayEnvStats property: inputCurrent
Explanation
Recommended Action
Fault Details
mibFaultName: tcaMemoryInputCurrent
moClass: memory:ArrayEnvStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]/array-env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/memarray-[id]/array-env-stats
Affected MO: sys/rack-unit-[id]/board/memarray-[id]/array-env-stats
tcaMemoryInputCurrentMin
Fault Code: F38359
Message
Threshold Crossed: memory:ArrayEnvStats property: inputCurrentMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaMemoryInputCurrentMin
moClass: memory:ArrayEnvStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]/array-env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/memarray-[id]/array-env-stats
Affected MO: sys/rack-unit-[id]/board/memarray-[id]/array-env-stats
tcaMemoryInputCurrentMax
Fault Code: F38360
Message
Threshold Crossed: memory:ArrayEnvStats property: inputCurrentMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaMemoryInputCurrentMax
moClass: memory:ArrayEnvStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]/array-env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/memarray-[id]/array-env-stats
Affected MO: sys/rack-unit-[id]/board/memarray-[id]/array-env-stats
tcaMemoryInputCurrentAvg
Fault Code: F38361
Message
Threshold Crossed: memory:ArrayEnvStats property: inputCurrentAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaMemoryInputCurrentAvg
moClass: memory:ArrayEnvStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]/array-env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/memarray-[id]/array-env-stats
Affected MO: sys/rack-unit-[id]/board/memarray-[id]/array-env-stats
tcaAdaptorNoBreakdownGreaterThan1518Delta
Fault Code: F38408
Message
Threshold Crossed: adaptor:EthPortBySizeLargeStats property: noBreakdownGreaterThan1518Delta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorNoBreakdownGreaterThan1518Delta
moClass: adaptor:EthPortBySizeLargeStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
tcaAdaptorNoBreakdownGreaterThan1518DeltaMin
Fault Code: F38409
Message
Threshold Crossed: adaptor:EthPortBySizeLargeStats property: noBreakdownGreaterThan1518DeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorNoBreakdownGreaterThan1518DeltaMin
moClass: adaptor:EthPortBySizeLargeStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
tcaAdaptorNoBreakdownGreaterThan1518DeltaMax
Fault Code: F38410
Message
Threshold Crossed: adaptor:EthPortBySizeLargeStats property: noBreakdownGreaterThan1518DeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorNoBreakdownGreaterThan1518DeltaMax
moClass: adaptor:EthPortBySizeLargeStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
tcaAdaptorNoBreakdownGreaterThan1518DeltaAvg
Fault Code: F38411
Message
Threshold Crossed: adaptor:EthPortBySizeLargeStats property: noBreakdownGreaterThan1518DeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaAdaptorNoBreakdownGreaterThan1518DeltaAvg
moClass: adaptor:EthPortBySizeLargeStats
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/computeEp-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/hv-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
Affected MO: vmm/vm-[uuid]/nic-[name]/eth-port-by-size-large-stats-[trafficDirection]
tcaMemoryTemperature
Fault Code: F38438
Message
Threshold Crossed: memory:BufferUnitEnvStats property: temperature
Explanation
Recommended Action
Fault Details
mibFaultName: tcaMemoryTemperature
moClass: memory:BufferUnitEnvStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sensor-unit-[id]/buffer-unit-env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sensor-unit-[id]/buffer-unit-env-stats
Affected MO: sys/rack-unit-[id]/board/sensor-unit-[id]/buffer-unit-env-stats
tcaMemoryTemperatureMin
Fault Code: F38440
Message
Threshold Crossed: memory:BufferUnitEnvStats property: temperatureMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaMemoryTemperatureMin
moClass: memory:BufferUnitEnvStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sensor-unit-[id]/buffer-unit-env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sensor-unit-[id]/buffer-unit-env-stats
Affected MO: sys/rack-unit-[id]/board/sensor-unit-[id]/buffer-unit-env-stats
tcaMemoryTemperatureMax
Fault Code: F38441
Message
Threshold Crossed: memory:BufferUnitEnvStats property: temperatureMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaMemoryTemperatureMax
moClass: memory:BufferUnitEnvStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sensor-unit-[id]/buffer-unit-env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sensor-unit-[id]/buffer-unit-env-stats
Affected MO: sys/rack-unit-[id]/board/sensor-unit-[id]/buffer-unit-env-stats
tcaMemoryTemperatureAvg
Fault Code: F38442
Message
Threshold Crossed: memory:BufferUnitEnvStats property: temperatureAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaMemoryTemperatureAvg
moClass: memory:BufferUnitEnvStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sensor-unit-[id]/buffer-unit-env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sensor-unit-[id]/buffer-unit-env-stats
Affected MO: sys/rack-unit-[id]/board/sensor-unit-[id]/buffer-unit-env-stats
tcaComputeTemperature
Fault Code: F38451
Message
Threshold Crossed: compute:IOHubEnvStats property: temperature
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeTemperature
moClass: compute:IOHubEnvStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/iohub/iohub-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/iohub/iohub-stats
Affected MO: sys/rack-unit-[id]/board/iohub/iohub-stats
tcaComputeTemperatureMin
Fault Code: F38453
Message
Threshold Crossed: compute:IOHubEnvStats property: temperatureMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeTemperatureMin
moClass: compute:IOHubEnvStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/iohub/iohub-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/iohub/iohub-stats
Affected MO: sys/rack-unit-[id]/board/iohub/iohub-stats
tcaComputeTemperatureMax
Fault Code: F38454
Message
Threshold Crossed: compute:IOHubEnvStats property: temperatureMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeTemperatureMax
moClass: compute:IOHubEnvStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/iohub/iohub-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/iohub/iohub-stats
Affected MO: sys/rack-unit-[id]/board/iohub/iohub-stats
tcaComputeTemperatureAvg
Fault Code: F38455
Message
Threshold Crossed: compute:IOHubEnvStats property: temperatureAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeTemperatureAvg
moClass: compute:IOHubEnvStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/iohub/iohub-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/iohub/iohub-stats
Affected MO: sys/rack-unit-[id]/board/iohub/iohub-stats
tcaProcessorMirroringIntraSockErrors
Fault Code: F38779
Message
Threshold Crossed: processor:ErrorStats property: mirroringIntraSockErrors
Explanation
Recommended Action
Fault Details
mibFaultName: tcaProcessorMirroringIntraSockErrors
moClass: processor:ErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]/error-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/cpu-[id]/error-stats
Affected MO: sys/rack-unit-[id]/board/cpu-[id]/error-stats
tcaProcessorMirroringInterSockErrors
Fault Code: F38788
Message
Threshold Crossed: processor:ErrorStats property: mirroringInterSockErrors
Explanation
Recommended Action
Fault Details
mibFaultName: tcaProcessorMirroringInterSockErrors
moClass: processor:ErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]/error-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/cpu-[id]/error-stats
Affected MO: sys/rack-unit-[id]/board/cpu-[id]/error-stats
tcaProcessorSparingErrors
Fault Code: F38797
Message
Threshold Crossed: processor:ErrorStats property: sparingErrors
Explanation
Recommended Action
Fault Details
mibFaultName: tcaProcessorSparingErrors
moClass: processor:ErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]/error-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/cpu-[id]/error-stats
Affected MO: sys/rack-unit-[id]/board/cpu-[id]/error-stats
tcaProcessorSmiLinkCorrErrors
Fault Code: F38806
Message
Threshold Crossed: processor:ErrorStats property: smiLinkCorrErrors
Explanation
Recommended Action
Fault Details
mibFaultName: tcaProcessorSmiLinkCorrErrors
moClass: processor:ErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]/error-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/cpu-[id]/error-stats
Affected MO: sys/rack-unit-[id]/board/cpu-[id]/error-stats
tcaProcessorSmiLinkUncorrErrors
Fault Code: F38815
Message
Threshold Crossed: processor:ErrorStats property: smiLinkUncorrErrors
Explanation
Recommended Action
Fault Details
mibFaultName: tcaProcessorSmiLinkUncorrErrors
moClass: processor:ErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]/error-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/cpu-[id]/error-stats
Affected MO: sys/rack-unit-[id]/board/cpu-[id]/error-stats
tcaMemoryEccMultibitErrors
Fault Code: F38829
Message
Threshold Crossed: memory:ErrorStats property: eccMultibitErrors
Explanation
Recommended Action
Fault Details
mibFaultName: tcaMemoryEccMultibitErrors
moClass: memory:ErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]/mem-[id]/error-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/memarray-[id]/mem-[id]/error-stats
Affected MO: sys/rack-unit-[id]/board/memarray-[id]/mem-[id]/error-stats
tcaMemoryEccSinglebitErrors
Fault Code: F38838
Message
Threshold Crossed: memory:ErrorStats property: eccSinglebitErrors
Explanation
Recommended Action
Fault Details
mibFaultName: tcaMemoryEccSinglebitErrors
moClass: memory:ErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]/mem-[id]/error-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/memarray-[id]/mem-[id]/error-stats
Affected MO: sys/rack-unit-[id]/board/memarray-[id]/mem-[id]/error-stats
tcaMemoryAddressParityErrors
Fault Code: F38847
Message
Threshold Crossed: memory:ErrorStats property: addressParityErrors
Explanation
Recommended Action
Fault Details
mibFaultName: tcaMemoryAddressParityErrors
moClass: memory:ErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]/mem-[id]/error-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/memarray-[id]/mem-[id]/error-stats
Affected MO: sys/rack-unit-[id]/board/memarray-[id]/mem-[id]/error-stats
tcaMemoryMismatchErrors
Fault Code: F38856
Message
Threshold Crossed: memory:ErrorStats property: mismatchErrors
Explanation
Recommended Action
Fault Details
mibFaultName: tcaMemoryMismatchErrors
moClass: memory:ErrorStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]/mem-[id]/error-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/memarray-[id]/mem-[id]/error-stats
Affected MO: sys/rack-unit-[id]/board/memarray-[id]/mem-[id]/error-stats
tcaComputeBufferOverflowErrors
Fault Code: F38909
Message
Threshold Crossed: compute:PCIeFatalReceiveStats property: bufferOverflowErrors
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeBufferOverflowErrors
moClass: compute:PCIeFatalReceiveStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/pciefat-receive-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/pciefat-receive-stats
Affected MO: sys/rack-unit-[id]/board/pciefat-receive-stats
tcaComputeFmTempSenRearL
Fault Code: F39032
Message
Threshold Crossed: compute:MbTempStats property: fmTempSenRearL
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeFmTempSenRearL
moClass: compute:MbTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/temp-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/temp-stats
Affected MO: sys/rack-unit-[id]/board/temp-stats
Affected MO: sys/rack-unit-[id]/ext-board-[id]/temp-stats
tcaComputeFmTempSenRearLMin
Fault Code: F39034
Message
Threshold Crossed: compute:MbTempStats property: fmTempSenRearLMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeFmTempSenRearLMin
moClass: compute:MbTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/temp-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/temp-stats
Affected MO: sys/rack-unit-[id]/board/temp-stats
Affected MO: sys/rack-unit-[id]/ext-board-[id]/temp-stats
tcaComputeFmTempSenRearLMax
Fault Code: F39035
Message
Threshold Crossed: compute:MbTempStats property: fmTempSenRearLMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeFmTempSenRearLMax
moClass: compute:MbTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/temp-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/temp-stats
Affected MO: sys/rack-unit-[id]/board/temp-stats
Affected MO: sys/rack-unit-[id]/ext-board-[id]/temp-stats
tcaComputeFmTempSenRearLAvg
Fault Code: F39036
Message
Threshold Crossed: compute:MbTempStats property: fmTempSenRearLAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeFmTempSenRearLAvg
moClass: compute:MbTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/temp-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/temp-stats
Affected MO: sys/rack-unit-[id]/board/temp-stats
Affected MO: sys/rack-unit-[id]/ext-board-[id]/temp-stats
tcaComputeFmTempSenRearR
Fault Code: F39040
Message
Threshold Crossed: compute:MbTempStats property: fmTempSenRearR
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeFmTempSenRearR
moClass: compute:MbTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/temp-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/temp-stats
Affected MO: sys/rack-unit-[id]/board/temp-stats
Affected MO: sys/rack-unit-[id]/ext-board-[id]/temp-stats
tcaComputeFmTempSenRearRMin
Fault Code: F39042
Message
Threshold Crossed: compute:MbTempStats property: fmTempSenRearRMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeFmTempSenRearRMin
moClass: compute:MbTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/temp-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/temp-stats
Affected MO: sys/rack-unit-[id]/board/temp-stats
Affected MO: sys/rack-unit-[id]/ext-board-[id]/temp-stats
tcaComputeFmTempSenRearRMax
Fault Code: F39043
Message
Threshold Crossed: compute:MbTempStats property: fmTempSenRearRMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeFmTempSenRearRMax
moClass: compute:MbTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/temp-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/temp-stats
Affected MO: sys/rack-unit-[id]/board/temp-stats
Affected MO: sys/rack-unit-[id]/ext-board-[id]/temp-stats
tcaComputeFmTempSenRearRAvg
Fault Code: F39044
Message
Threshold Crossed: compute:MbTempStats property: fmTempSenRearRAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeFmTempSenRearRAvg
moClass: compute:MbTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/temp-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/temp-stats
Affected MO: sys/rack-unit-[id]/board/temp-stats
Affected MO: sys/rack-unit-[id]/ext-board-[id]/temp-stats
tcaPowerPower
Fault Code: F39240
Message
Threshold Crossed: power:GroupStats property: power
Explanation
Recommended Action
Fault Details
mibFaultName: tcaPowerPower
moClass: power:GroupStats
tcaPowerPowerMin
Fault Code: F39242
Message
Threshold Crossed: power:GroupStats property: powerMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaPowerPowerMin
moClass: power:GroupStats
tcaPowerPowerMax
Fault Code: F39243
Message
Threshold Crossed: power:GroupStats property: powerMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaPowerPowerMax
moClass: power:GroupStats
tcaPowerPowerAvg
Fault Code: F39244
Message
Threshold Crossed: power:GroupStats property: powerAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaPowerPowerAvg
moClass: power:GroupStats
tcaEquipmentOutlet1
Fault Code: F39421
Message
Threshold Crossed: equipment:FexEnvStats property: outlet1
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutlet1
moClass: equipment:FexEnvStats
Affected MO: sys/fex-[id]/env-stats
tcaEquipmentOutlet1Min
Fault Code: F39423
Message
Threshold Crossed: equipment:FexEnvStats property: outlet1Min
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutlet1Min
moClass: equipment:FexEnvStats
Affected MO: sys/fex-[id]/env-stats
tcaEquipmentOutlet1Max
Fault Code: F39424
Message
Threshold Crossed: equipment:FexEnvStats property: outlet1Max
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutlet1Max
moClass: equipment:FexEnvStats
Affected MO: sys/fex-[id]/env-stats
tcaEquipmentOutlet1Avg
Fault Code: F39425
Message
Threshold Crossed: equipment:FexEnvStats property: outlet1Avg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutlet1Avg
moClass: equipment:FexEnvStats
Affected MO: sys/fex-[id]/env-stats
tcaEquipmentOutlet2
Fault Code: F39429
Message
Threshold Crossed: equipment:FexEnvStats property: outlet2
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutlet2
moClass: equipment:FexEnvStats
Affected MO: sys/fex-[id]/env-stats
tcaEquipmentOutlet2Min
Fault Code: F39431
Message
Threshold Crossed: equipment:FexEnvStats property: outlet2Min
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutlet2Min
moClass: equipment:FexEnvStats
Affected MO: sys/fex-[id]/env-stats
tcaEquipmentOutlet2Max
Fault Code: F39432
Message
Threshold Crossed: equipment:FexEnvStats property: outlet2Max
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutlet2Max
moClass: equipment:FexEnvStats
Affected MO: sys/fex-[id]/env-stats
tcaEquipmentOutlet2Avg
Fault Code: F39433
Message
Threshold Crossed: equipment:FexEnvStats property: outlet2Avg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutlet2Avg
moClass: equipment:FexEnvStats
Affected MO: sys/fex-[id]/env-stats
tcaEquipmentInlet
Fault Code: F39437
Message
Threshold Crossed: equipment:FexEnvStats property: inlet
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentInlet
moClass: equipment:FexEnvStats
Affected MO: sys/fex-[id]/env-stats
tcaEquipmentInletMin
Fault Code: F39439
Message
Threshold Crossed: equipment:FexEnvStats property: inletMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentInletMin
moClass: equipment:FexEnvStats
Affected MO: sys/fex-[id]/env-stats
tcaEquipmentInletMax
Fault Code: F39440
Message
Threshold Crossed: equipment:FexEnvStats property: inletMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentInletMax
moClass: equipment:FexEnvStats
Affected MO: sys/fex-[id]/env-stats
tcaEquipmentInletAvg
Fault Code: F39441
Message
Threshold Crossed: equipment:FexEnvStats property: inletAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentInletAvg
moClass: equipment:FexEnvStats
Affected MO: sys/fex-[id]/env-stats
tcaEquipmentInlet1
Fault Code: F39445
Message
Threshold Crossed: equipment:FexEnvStats property: inlet1
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentInlet1
moClass: equipment:FexEnvStats
Affected MO: sys/fex-[id]/env-stats
tcaEquipmentInlet1Min
Fault Code: F39447
Message
Threshold Crossed: equipment:FexEnvStats property: inlet1Min
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentInlet1Min
moClass: equipment:FexEnvStats
Affected MO: sys/fex-[id]/env-stats
tcaEquipmentInlet1Max
Fault Code: F39448
Message
Threshold Crossed: equipment:FexEnvStats property: inlet1Max
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentInlet1Max
moClass: equipment:FexEnvStats
Affected MO: sys/fex-[id]/env-stats
tcaEquipmentInlet1Avg
Fault Code: F39449
Message
Threshold Crossed: equipment:FexEnvStats property: inlet1Avg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentInlet1Avg
moClass: equipment:FexEnvStats
Affected MO: sys/fex-[id]/env-stats
tcaEquipmentDie1
Fault Code: F39453
Message
Threshold Crossed: equipment:FexEnvStats property: die1
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentDie1
moClass: equipment:FexEnvStats
Affected MO: sys/fex-[id]/env-stats
tcaEquipmentDie1Min
Fault Code: F39455
Message
Threshold Crossed: equipment:FexEnvStats property: die1Min
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentDie1Min
moClass: equipment:FexEnvStats
Affected MO: sys/fex-[id]/env-stats
tcaEquipmentDie1Max
Fault Code: F39456
Message
Threshold Crossed: equipment:FexEnvStats property: die1Max
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentDie1Max
moClass: equipment:FexEnvStats
Affected MO: sys/fex-[id]/env-stats
tcaEquipmentDie1Avg
Fault Code: F39457
Message
Threshold Crossed: equipment:FexEnvStats property: die1Avg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentDie1Avg
moClass: equipment:FexEnvStats
Affected MO: sys/fex-[id]/env-stats
tcaEquipmentTotalPower
Fault Code: F39464
Message
Threshold Crossed: equipment:FexPowerSummary property: totalPower
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentTotalPower
moClass: equipment:FexPowerSummary
Affected MO: sys/fex-[id]/power-summary
tcaEquipmentTotalPowerMin
Fault Code: F39466
Message
Threshold Crossed: equipment:FexPowerSummary property: totalPowerMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentTotalPowerMin
moClass: equipment:FexPowerSummary
Affected MO: sys/fex-[id]/power-summary
tcaEquipmentTotalPowerMax
Fault Code: F39467
Message
Threshold Crossed: equipment:FexPowerSummary property: totalPowerMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentTotalPowerMax
moClass: equipment:FexPowerSummary
Affected MO: sys/fex-[id]/power-summary
tcaEquipmentTotalPowerAvg
Fault Code: F39468
Message
Threshold Crossed: equipment:FexPowerSummary property: totalPowerAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentTotalPowerAvg
moClass: equipment:FexPowerSummary
Affected MO: sys/fex-[id]/power-summary
tcaEquipmentReservedPower
Fault Code: F39472
Message
Threshold Crossed: equipment:FexPowerSummary property: reservedPower
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentReservedPower
moClass: equipment:FexPowerSummary
Affected MO: sys/fex-[id]/power-summary
tcaEquipmentReservedPowerMin
Fault Code: F39474
Message
Threshold Crossed: equipment:FexPowerSummary property: reservedPowerMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentReservedPowerMin
moClass: equipment:FexPowerSummary
Affected MO: sys/fex-[id]/power-summary
tcaEquipmentReservedPowerMax
Fault Code: F39475
Message
Threshold Crossed: equipment:FexPowerSummary property: reservedPowerMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentReservedPowerMax
moClass: equipment:FexPowerSummary
Affected MO: sys/fex-[id]/power-summary
tcaEquipmentReservedPowerAvg
Fault Code: F39476
Message
Threshold Crossed: equipment:FexPowerSummary property: reservedPowerAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentReservedPowerAvg
moClass: equipment:FexPowerSummary
Affected MO: sys/fex-[id]/power-summary
tcaEquipmentModulePower
Fault Code: F39480
Message
Threshold Crossed: equipment:FexPowerSummary property: ModulePower
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentModulePower
moClass: equipment:FexPowerSummary
Affected MO: sys/fex-[id]/power-summary
tcaEquipmentModulePowerMin
Fault Code: F39482
Message
Threshold Crossed: equipment:FexPowerSummary property: ModulePowerMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentModulePowerMin
moClass: equipment:FexPowerSummary
Affected MO: sys/fex-[id]/power-summary
tcaEquipmentModulePowerMax
Fault Code: F39483
Message
Threshold Crossed: equipment:FexPowerSummary property: ModulePowerMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentModulePowerMax
moClass: equipment:FexPowerSummary
Affected MO: sys/fex-[id]/power-summary
tcaEquipmentModulePowerAvg
Fault Code: F39484
Message
Threshold Crossed: equipment:FexPowerSummary property: ModulePowerAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentModulePowerAvg
moClass: equipment:FexPowerSummary
Affected MO: sys/fex-[id]/power-summary
tcaEquipmentAvailablePower
Fault Code: F39488
Message
Threshold Crossed: equipment:FexPowerSummary property: availablePower
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentAvailablePower
moClass: equipment:FexPowerSummary
Affected MO: sys/fex-[id]/power-summary
tcaEquipmentAvailablePowerMin
Fault Code: F39490
Message
Threshold Crossed: equipment:FexPowerSummary property: availablePowerMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentAvailablePowerMin
moClass: equipment:FexPowerSummary
Affected MO: sys/fex-[id]/power-summary
tcaEquipmentAvailablePowerMax
Fault Code: F39491
Message
Threshold Crossed: equipment:FexPowerSummary property: availablePowerMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentAvailablePowerMax
moClass: equipment:FexPowerSummary
Affected MO: sys/fex-[id]/power-summary
tcaEquipmentAvailablePowerAvg
Fault Code: F39492
Message
Threshold Crossed: equipment:FexPowerSummary property: availablePowerAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentAvailablePowerAvg
moClass: equipment:FexPowerSummary
Affected MO: sys/fex-[id]/power-summary
tcaEquipmentCurrent
Fault Code: F39498
Message
Threshold Crossed: equipment:FexPsuInputStats property: current
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentCurrent
moClass: equipment:FexPsuInputStats
Affected MO: sys/chassis-[id]/psu-[id]/fex-psu-input-stats
Affected MO: sys/fex-[id]/fex-psu-input-stats
Affected MO: sys/fex-[id]/psu-[id]/fex-psu-input-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/fex-psu-input-stats
Affected MO: sys/switch-[id]/psu-[id]/fex-psu-input-stats
tcaEquipmentCurrentMin
Fault Code: F39500
Message
Threshold Crossed: equipment:FexPsuInputStats property: currentMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentCurrentMin
moClass: equipment:FexPsuInputStats
Affected MO: sys/chassis-[id]/psu-[id]/fex-psu-input-stats
Affected MO: sys/fex-[id]/fex-psu-input-stats
Affected MO: sys/fex-[id]/psu-[id]/fex-psu-input-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/fex-psu-input-stats
Affected MO: sys/switch-[id]/psu-[id]/fex-psu-input-stats
tcaEquipmentCurrentMax
Fault Code: F39501
Message
Threshold Crossed: equipment:FexPsuInputStats property: currentMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentCurrentMax
moClass: equipment:FexPsuInputStats
Affected MO: sys/chassis-[id]/psu-[id]/fex-psu-input-stats
Affected MO: sys/fex-[id]/fex-psu-input-stats
Affected MO: sys/fex-[id]/psu-[id]/fex-psu-input-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/fex-psu-input-stats
Affected MO: sys/switch-[id]/psu-[id]/fex-psu-input-stats
tcaEquipmentCurrentAvg
Fault Code: F39502
Message
Threshold Crossed: equipment:FexPsuInputStats property: currentAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentCurrentAvg
moClass: equipment:FexPsuInputStats
Affected MO: sys/chassis-[id]/psu-[id]/fex-psu-input-stats
Affected MO: sys/fex-[id]/fex-psu-input-stats
Affected MO: sys/fex-[id]/psu-[id]/fex-psu-input-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/fex-psu-input-stats
Affected MO: sys/switch-[id]/psu-[id]/fex-psu-input-stats
tcaEquipmentVoltage
Fault Code: F39506
Message
Threshold Crossed: equipment:FexPsuInputStats property: voltage
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentVoltage
moClass: equipment:FexPsuInputStats
Affected MO: sys/chassis-[id]/psu-[id]/fex-psu-input-stats
Affected MO: sys/fex-[id]/fex-psu-input-stats
Affected MO: sys/fex-[id]/psu-[id]/fex-psu-input-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/fex-psu-input-stats
Affected MO: sys/switch-[id]/psu-[id]/fex-psu-input-stats
tcaEquipmentVoltageMin
Fault Code: F39508
Message
Threshold Crossed: equipment:FexPsuInputStats property: voltageMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentVoltageMin
moClass: equipment:FexPsuInputStats
Affected MO: sys/chassis-[id]/psu-[id]/fex-psu-input-stats
Affected MO: sys/fex-[id]/fex-psu-input-stats
Affected MO: sys/fex-[id]/psu-[id]/fex-psu-input-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/fex-psu-input-stats
Affected MO: sys/switch-[id]/psu-[id]/fex-psu-input-stats
tcaEquipmentVoltageMax
Fault Code: F39509
Message
Threshold Crossed: equipment:FexPsuInputStats property: voltageMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentVoltageMax
moClass: equipment:FexPsuInputStats
Affected MO: sys/chassis-[id]/psu-[id]/fex-psu-input-stats
Affected MO: sys/fex-[id]/fex-psu-input-stats
Affected MO: sys/fex-[id]/psu-[id]/fex-psu-input-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/fex-psu-input-stats
Affected MO: sys/switch-[id]/psu-[id]/fex-psu-input-stats
tcaEquipmentVoltageAvg
Fault Code: F39510
Message
Threshold Crossed: equipment:FexPsuInputStats property: voltageAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentVoltageAvg
moClass: equipment:FexPsuInputStats
Affected MO: sys/chassis-[id]/psu-[id]/fex-psu-input-stats
Affected MO: sys/fex-[id]/fex-psu-input-stats
Affected MO: sys/fex-[id]/psu-[id]/fex-psu-input-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/fex-psu-input-stats
Affected MO: sys/switch-[id]/psu-[id]/fex-psu-input-stats
tcaEquipmentPower
Fault Code: F39514
Message
Threshold Crossed: equipment:FexPsuInputStats property: power
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentPower
moClass: equipment:FexPsuInputStats
Affected MO: sys/chassis-[id]/psu-[id]/fex-psu-input-stats
Affected MO: sys/fex-[id]/fex-psu-input-stats
Affected MO: sys/fex-[id]/psu-[id]/fex-psu-input-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/fex-psu-input-stats
Affected MO: sys/switch-[id]/psu-[id]/fex-psu-input-stats
tcaEquipmentPowerMin
Fault Code: F39516
Message
Threshold Crossed: equipment:FexPsuInputStats property: powerMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentPowerMin
moClass: equipment:FexPsuInputStats
Affected MO: sys/chassis-[id]/psu-[id]/fex-psu-input-stats
Affected MO: sys/fex-[id]/fex-psu-input-stats
Affected MO: sys/fex-[id]/psu-[id]/fex-psu-input-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/fex-psu-input-stats
Affected MO: sys/switch-[id]/psu-[id]/fex-psu-input-stats
tcaEquipmentPowerMax
Fault Code: F39517
Message
Threshold Crossed: equipment:FexPsuInputStats property: powerMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentPowerMax
moClass: equipment:FexPsuInputStats
Affected MO: sys/chassis-[id]/psu-[id]/fex-psu-input-stats
Affected MO: sys/fex-[id]/fex-psu-input-stats
Affected MO: sys/fex-[id]/psu-[id]/fex-psu-input-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/fex-psu-input-stats
Affected MO: sys/switch-[id]/psu-[id]/fex-psu-input-stats
tcaEquipmentPowerAvg
Fault Code: F39518
Message
Threshold Crossed: equipment:FexPsuInputStats property: powerAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentPowerAvg
moClass: equipment:FexPsuInputStats
Affected MO: sys/chassis-[id]/psu-[id]/fex-psu-input-stats
Affected MO: sys/fex-[id]/fex-psu-input-stats
Affected MO: sys/fex-[id]/psu-[id]/fex-psu-input-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/fex-psu-input-stats
Affected MO: sys/switch-[id]/psu-[id]/fex-psu-input-stats
tcaEquipmentAmbientTemp
Fault Code: F39525
Message
Threshold Crossed: equipment:RackUnitPsuStats property: ambientTemp
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentAmbientTemp
moClass: equipment:RackUnitPsuStats
Affected MO: sys/chassis-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/fex-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/switch-[id]/psu-[id]/rackunit-power-stats
tcaEquipmentAmbientTempMin
Fault Code: F39527
Message
Threshold Crossed: equipment:RackUnitPsuStats property: ambientTempMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentAmbientTempMin
moClass: equipment:RackUnitPsuStats
Affected MO: sys/chassis-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/fex-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/switch-[id]/psu-[id]/rackunit-power-stats
tcaEquipmentAmbientTempMax
Fault Code: F39528
Message
Threshold Crossed: equipment:RackUnitPsuStats property: ambientTempMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentAmbientTempMax
moClass: equipment:RackUnitPsuStats
Affected MO: sys/chassis-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/fex-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/switch-[id]/psu-[id]/rackunit-power-stats
tcaEquipmentAmbientTempAvg
Fault Code: F39529
Message
Threshold Crossed: equipment:RackUnitPsuStats property: ambientTempAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentAmbientTempAvg
moClass: equipment:RackUnitPsuStats
Affected MO: sys/chassis-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/fex-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/switch-[id]/psu-[id]/rackunit-power-stats
tcaEquipmentOutputCurrent
Fault Code: F39533
Message
Threshold Crossed: equipment:RackUnitPsuStats property: outputCurrent
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutputCurrent
moClass: equipment:RackUnitPsuStats
Affected MO: sys/chassis-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/fex-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/switch-[id]/psu-[id]/rackunit-power-stats
tcaEquipmentOutputCurrentMin
Fault Code: F39535
Message
Threshold Crossed: equipment:RackUnitPsuStats property: outputCurrentMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutputCurrentMin
moClass: equipment:RackUnitPsuStats
Affected MO: sys/chassis-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/fex-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/switch-[id]/psu-[id]/rackunit-power-stats
tcaEquipmentOutputCurrentMax
Fault Code: F39536
Message
Threshold Crossed: equipment:RackUnitPsuStats property: outputCurrentMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutputCurrentMax
moClass: equipment:RackUnitPsuStats
Affected MO: sys/chassis-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/fex-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/switch-[id]/psu-[id]/rackunit-power-stats
tcaEquipmentOutputCurrentAvg
Fault Code: F39537
Message
Threshold Crossed: equipment:RackUnitPsuStats property: outputCurrentAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutputCurrentAvg
moClass: equipment:RackUnitPsuStats
Affected MO: sys/chassis-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/fex-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/switch-[id]/psu-[id]/rackunit-power-stats
tcaEquipmentOutputPower
Fault Code: F39541
Message
Threshold Crossed: equipment:RackUnitPsuStats property: outputPower
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutputPower
moClass: equipment:RackUnitPsuStats
Affected MO: sys/chassis-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/fex-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/switch-[id]/psu-[id]/rackunit-power-stats
tcaEquipmentOutputPowerMin
Fault Code: F39543
Message
Threshold Crossed: equipment:RackUnitPsuStats property: outputPowerMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutputPowerMin
moClass: equipment:RackUnitPsuStats
Affected MO: sys/chassis-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/fex-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/switch-[id]/psu-[id]/rackunit-power-stats
tcaEquipmentOutputPowerMax
Fault Code: F39544
Message
Threshold Crossed: equipment:RackUnitPsuStats property: outputPowerMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutputPowerMax
moClass: equipment:RackUnitPsuStats
Affected MO: sys/chassis-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/fex-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/switch-[id]/psu-[id]/rackunit-power-stats
tcaEquipmentOutputPowerAvg
Fault Code: F39545
Message
Threshold Crossed: equipment:RackUnitPsuStats property: outputPowerAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutputPowerAvg
moClass: equipment:RackUnitPsuStats
Affected MO: sys/chassis-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/fex-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/switch-[id]/psu-[id]/rackunit-power-stats
tcaEquipmentInputPower
Fault Code: F39549
Message
Threshold Crossed: equipment:RackUnitPsuStats property: inputPower
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentInputPower
moClass: equipment:RackUnitPsuStats
Affected MO: sys/chassis-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/fex-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/switch-[id]/psu-[id]/rackunit-power-stats
tcaEquipmentInputPowerMin
Fault Code: F39551
Message
Threshold Crossed: equipment:RackUnitPsuStats property: inputPowerMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentInputPowerMin
moClass: equipment:RackUnitPsuStats
Affected MO: sys/chassis-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/fex-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/switch-[id]/psu-[id]/rackunit-power-stats
tcaEquipmentInputPowerMax
Fault Code: F39552
Message
Threshold Crossed: equipment:RackUnitPsuStats property: inputPowerMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentInputPowerMax
moClass: equipment:RackUnitPsuStats
Affected MO: sys/chassis-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/fex-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/switch-[id]/psu-[id]/rackunit-power-stats
tcaEquipmentInputPowerAvg
Fault Code: F39553
Message
Threshold Crossed: equipment:RackUnitPsuStats property: inputPowerAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentInputPowerAvg
moClass: equipment:RackUnitPsuStats
Affected MO: sys/chassis-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/fex-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/switch-[id]/psu-[id]/rackunit-power-stats
tcaEquipmentOutputVoltage
Fault Code: F39557
Message
Threshold Crossed: equipment:RackUnitPsuStats property: outputVoltage
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutputVoltage
moClass: equipment:RackUnitPsuStats
Affected MO: sys/chassis-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/fex-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/switch-[id]/psu-[id]/rackunit-power-stats
tcaEquipmentOutputVoltageMin
Fault Code: F39559
Message
Threshold Crossed: equipment:RackUnitPsuStats property: outputVoltageMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutputVoltageMin
moClass: equipment:RackUnitPsuStats
Affected MO: sys/chassis-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/fex-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/switch-[id]/psu-[id]/rackunit-power-stats
tcaEquipmentOutputVoltageMax
Fault Code: F39560
Message
Threshold Crossed: equipment:RackUnitPsuStats property: outputVoltageMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutputVoltageMax
moClass: equipment:RackUnitPsuStats
Affected MO: sys/chassis-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/fex-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/switch-[id]/psu-[id]/rackunit-power-stats
tcaEquipmentOutputVoltageAvg
Fault Code: F39561
Message
Threshold Crossed: equipment:RackUnitPsuStats property: outputVoltageAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentOutputVoltageAvg
moClass: equipment:RackUnitPsuStats
Affected MO: sys/chassis-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/fex-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/switch-[id]/psu-[id]/rackunit-power-stats
tcaEquipmentInputVoltage
Fault Code: F39565
Message
Threshold Crossed: equipment:RackUnitPsuStats property: inputVoltage
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentInputVoltage
moClass: equipment:RackUnitPsuStats
Affected MO: sys/chassis-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/fex-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/switch-[id]/psu-[id]/rackunit-power-stats
tcaEquipmentInputVoltageMin
Fault Code: F39567
Message
Threshold Crossed: equipment:RackUnitPsuStats property: inputVoltageMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentInputVoltageMin
moClass: equipment:RackUnitPsuStats
Affected MO: sys/chassis-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/fex-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/switch-[id]/psu-[id]/rackunit-power-stats
tcaEquipmentInputVoltageMax
Fault Code: F39568
Message
Threshold Crossed: equipment:RackUnitPsuStats property: inputVoltageMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentInputVoltageMax
moClass: equipment:RackUnitPsuStats
Affected MO: sys/chassis-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/fex-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/switch-[id]/psu-[id]/rackunit-power-stats
tcaEquipmentInputVoltageAvg
Fault Code: F39569
Message
Threshold Crossed: equipment:RackUnitPsuStats property: inputVoltageAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentInputVoltageAvg
moClass: equipment:RackUnitPsuStats
Affected MO: sys/chassis-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/fex-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/rackunit-power-stats
Affected MO: sys/switch-[id]/psu-[id]/rackunit-power-stats
tcaEquipmentSpeed
Fault Code: F39575
Message
Threshold Crossed: equipment:RackUnitFanStats property: speed
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentSpeed
moClass: equipment:RackUnitFanStats
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]/stats
Affected MO: sys/fex-[id]/fan-[id]/stats
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]/stats
Affected MO: sys/switch-[id]/fan-[id]/stats
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]/stats
tcaEquipmentSpeedMin
Fault Code: F39577
Message
Threshold Crossed: equipment:RackUnitFanStats property: speedMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentSpeedMin
moClass: equipment:RackUnitFanStats
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]/stats
Affected MO: sys/fex-[id]/fan-[id]/stats
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]/stats
Affected MO: sys/switch-[id]/fan-[id]/stats
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]/stats
tcaEquipmentSpeedMax
Fault Code: F39578
Message
Threshold Crossed: equipment:RackUnitFanStats property: speedMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentSpeedMax
moClass: equipment:RackUnitFanStats
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]/stats
Affected MO: sys/fex-[id]/fan-[id]/stats
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]/stats
Affected MO: sys/switch-[id]/fan-[id]/stats
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]/stats
tcaEquipmentSpeedAvg
Fault Code: F39579
Message
Threshold Crossed: equipment:RackUnitFanStats property: speedAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentSpeedAvg
moClass: equipment:RackUnitFanStats
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]/stats
Affected MO: sys/fex-[id]/fan-[id]/stats
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]/stats
Affected MO: sys/switch-[id]/fan-[id]/stats
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]/stats
tcaComputeFrontTemp
Fault Code: F40092
Message
Threshold Crossed: compute:RackUnitMbTempStats property: frontTemp
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeFrontTemp
moClass: compute:RackUnitMbTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/temp-stats
Affected MO: sys/rack-unit-[id]/board/temp-stats
tcaComputeFrontTempMin
Fault Code: F40094
Message
Threshold Crossed: compute:RackUnitMbTempStats property: frontTempMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeFrontTempMin
moClass: compute:RackUnitMbTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/temp-stats
Affected MO: sys/rack-unit-[id]/board/temp-stats
tcaComputeFrontTempMax
Fault Code: F40095
Message
Threshold Crossed: compute:RackUnitMbTempStats property: frontTempMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeFrontTempMax
moClass: compute:RackUnitMbTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/temp-stats
Affected MO: sys/rack-unit-[id]/board/temp-stats
tcaComputeFrontTempAvg
Fault Code: F40096
Message
Threshold Crossed: compute:RackUnitMbTempStats property: frontTempAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeFrontTempAvg
moClass: compute:RackUnitMbTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/temp-stats
Affected MO: sys/rack-unit-[id]/board/temp-stats
tcaComputeRearTemp
Fault Code: F40100
Message
Threshold Crossed: compute:RackUnitMbTempStats property: rearTemp
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeRearTemp
moClass: compute:RackUnitMbTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/temp-stats
Affected MO: sys/rack-unit-[id]/board/temp-stats
tcaComputeRearTempMin
Fault Code: F40102
Message
Threshold Crossed: compute:RackUnitMbTempStats property: rearTempMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeRearTempMin
moClass: compute:RackUnitMbTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/temp-stats
Affected MO: sys/rack-unit-[id]/board/temp-stats
tcaComputeRearTempMax
Fault Code: F40103
Message
Threshold Crossed: compute:RackUnitMbTempStats property: rearTempMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeRearTempMax
moClass: compute:RackUnitMbTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/temp-stats
Affected MO: sys/rack-unit-[id]/board/temp-stats
tcaComputeRearTempAvg
Fault Code: F40104
Message
Threshold Crossed: compute:RackUnitMbTempStats property: rearTempAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeRearTempAvg
moClass: compute:RackUnitMbTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/temp-stats
Affected MO: sys/rack-unit-[id]/board/temp-stats
tcaComputeAmbientTemp
Fault Code: F40108
Message
Threshold Crossed: compute:RackUnitMbTempStats property: ambientTemp
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeAmbientTemp
moClass: compute:RackUnitMbTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/temp-stats
Affected MO: sys/rack-unit-[id]/board/temp-stats
tcaComputeAmbientTempMin
Fault Code: F40110
Message
Threshold Crossed: compute:RackUnitMbTempStats property: ambientTempMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeAmbientTempMin
moClass: compute:RackUnitMbTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/temp-stats
Affected MO: sys/rack-unit-[id]/board/temp-stats
tcaComputeAmbientTempMax
Fault Code: F40111
Message
Threshold Crossed: compute:RackUnitMbTempStats property: ambientTempMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeAmbientTempMax
moClass: compute:RackUnitMbTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/temp-stats
Affected MO: sys/rack-unit-[id]/board/temp-stats
tcaComputeAmbientTempAvg
Fault Code: F40112
Message
Threshold Crossed: compute:RackUnitMbTempStats property: ambientTempAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeAmbientTempAvg
moClass: compute:RackUnitMbTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/temp-stats
Affected MO: sys/rack-unit-[id]/board/temp-stats
tcaComputeIoh1Temp
Fault Code: F40116
Message
Threshold Crossed: compute:RackUnitMbTempStats property: ioh1Temp
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeIoh1Temp
moClass: compute:RackUnitMbTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/temp-stats
Affected MO: sys/rack-unit-[id]/board/temp-stats
tcaComputeIoh1TempMin
Fault Code: F40118
Message
Threshold Crossed: compute:RackUnitMbTempStats property: ioh1TempMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeIoh1TempMin
moClass: compute:RackUnitMbTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/temp-stats
Affected MO: sys/rack-unit-[id]/board/temp-stats
tcaComputeIoh1TempMax
Fault Code: F40119
Message
Threshold Crossed: compute:RackUnitMbTempStats property: ioh1TempMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeIoh1TempMax
moClass: compute:RackUnitMbTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/temp-stats
Affected MO: sys/rack-unit-[id]/board/temp-stats
tcaComputeIoh1TempAvg
Fault Code: F40120
Message
Threshold Crossed: compute:RackUnitMbTempStats property: ioh1TempAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeIoh1TempAvg
moClass: compute:RackUnitMbTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/temp-stats
Affected MO: sys/rack-unit-[id]/board/temp-stats
tcaComputeIoh2Temp
Fault Code: F40124
Message
Threshold Crossed: compute:RackUnitMbTempStats property: ioh2Temp
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeIoh2Temp
moClass: compute:RackUnitMbTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/temp-stats
Affected MO: sys/rack-unit-[id]/board/temp-stats
tcaComputeIoh2TempMin
Fault Code: F40126
Message
Threshold Crossed: compute:RackUnitMbTempStats property: ioh2TempMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeIoh2TempMin
moClass: compute:RackUnitMbTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/temp-stats
Affected MO: sys/rack-unit-[id]/board/temp-stats
tcaComputeIoh2TempMax
Fault Code: F40127
Message
Threshold Crossed: compute:RackUnitMbTempStats property: ioh2TempMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeIoh2TempMax
moClass: compute:RackUnitMbTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/temp-stats
Affected MO: sys/rack-unit-[id]/board/temp-stats
tcaComputeIoh2TempAvg
Fault Code: F40128
Message
Threshold Crossed: compute:RackUnitMbTempStats property: ioh2TempAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaComputeIoh2TempAvg
moClass: compute:RackUnitMbTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/temp-stats
Affected MO: sys/rack-unit-[id]/board/temp-stats
tcaEquipmentCurrent
Fault Code: F40547
Message
Threshold Crossed: equipment:PsuOutputStats property: current
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentCurrent
moClass: equipment:PsuOutputStats
Affected MO: sys/chassis-[id]/psu-[id]/output-stats
Affected MO: sys/fex-[id]/psu-[id]/output-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/output-stats
Affected MO: sys/switch-[id]/psu-[id]/output-stats
tcaEquipmentCurrentMin
Fault Code: F40549
Message
Threshold Crossed: equipment:PsuOutputStats property: currentMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentCurrentMin
moClass: equipment:PsuOutputStats
Affected MO: sys/chassis-[id]/psu-[id]/output-stats
Affected MO: sys/fex-[id]/psu-[id]/output-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/output-stats
Affected MO: sys/switch-[id]/psu-[id]/output-stats
tcaEquipmentCurrentMax
Fault Code: F40550
Message
Threshold Crossed: equipment:PsuOutputStats property: currentMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentCurrentMax
moClass: equipment:PsuOutputStats
Affected MO: sys/chassis-[id]/psu-[id]/output-stats
Affected MO: sys/fex-[id]/psu-[id]/output-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/output-stats
Affected MO: sys/switch-[id]/psu-[id]/output-stats
tcaEquipmentCurrentAvg
Fault Code: F40551
Message
Threshold Crossed: equipment:PsuOutputStats property: currentAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentCurrentAvg
moClass: equipment:PsuOutputStats
Affected MO: sys/chassis-[id]/psu-[id]/output-stats
Affected MO: sys/fex-[id]/psu-[id]/output-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/output-stats
Affected MO: sys/switch-[id]/psu-[id]/output-stats
tcaEquipmentVoltage
Fault Code: F40555
Message
Threshold Crossed: equipment:PsuOutputStats property: voltage
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentVoltage
moClass: equipment:PsuOutputStats
Affected MO: sys/chassis-[id]/psu-[id]/output-stats
Affected MO: sys/fex-[id]/psu-[id]/output-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/output-stats
Affected MO: sys/switch-[id]/psu-[id]/output-stats
tcaEquipmentVoltageMin
Fault Code: F40557
Message
Threshold Crossed: equipment:PsuOutputStats property: voltageMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentVoltageMin
moClass: equipment:PsuOutputStats
Affected MO: sys/chassis-[id]/psu-[id]/output-stats
Affected MO: sys/fex-[id]/psu-[id]/output-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/output-stats
Affected MO: sys/switch-[id]/psu-[id]/output-stats
tcaEquipmentVoltageMax
Fault Code: F40558
Message
Threshold Crossed: equipment:PsuOutputStats property: voltageMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentVoltageMax
moClass: equipment:PsuOutputStats
Affected MO: sys/chassis-[id]/psu-[id]/output-stats
Affected MO: sys/fex-[id]/psu-[id]/output-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/output-stats
Affected MO: sys/switch-[id]/psu-[id]/output-stats
tcaEquipmentVoltageAvg
Fault Code: F40559
Message
Threshold Crossed: equipment:PsuOutputStats property: voltageAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentVoltageAvg
moClass: equipment:PsuOutputStats
Affected MO: sys/chassis-[id]/psu-[id]/output-stats
Affected MO: sys/fex-[id]/psu-[id]/output-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/output-stats
Affected MO: sys/switch-[id]/psu-[id]/output-stats
tcaEquipmentPower
Fault Code: F40563
Message
Threshold Crossed: equipment:PsuOutputStats property: power
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentPower
moClass: equipment:PsuOutputStats
Affected MO: sys/chassis-[id]/psu-[id]/output-stats
Affected MO: sys/fex-[id]/psu-[id]/output-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/output-stats
Affected MO: sys/switch-[id]/psu-[id]/output-stats
tcaEquipmentPowerMin
Fault Code: F40565
Message
Threshold Crossed: equipment:PsuOutputStats property: powerMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentPowerMin
moClass: equipment:PsuOutputStats
Affected MO: sys/chassis-[id]/psu-[id]/output-stats
Affected MO: sys/fex-[id]/psu-[id]/output-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/output-stats
Affected MO: sys/switch-[id]/psu-[id]/output-stats
tcaEquipmentPowerMax
Fault Code: F40566
Message
Threshold Crossed: equipment:PsuOutputStats property: powerMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentPowerMax
moClass: equipment:PsuOutputStats
Affected MO: sys/chassis-[id]/psu-[id]/output-stats
Affected MO: sys/fex-[id]/psu-[id]/output-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/output-stats
Affected MO: sys/switch-[id]/psu-[id]/output-stats
tcaEquipmentPowerAvg
Fault Code: F40567
Message
Threshold Crossed: equipment:PsuOutputStats property: powerAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentPowerAvg
moClass: equipment:PsuOutputStats
Affected MO: sys/chassis-[id]/psu-[id]/output-stats
Affected MO: sys/fex-[id]/psu-[id]/output-stats
Affected MO: sys/rack-unit-[id]/psu-[id]/output-stats
Affected MO: sys/switch-[id]/psu-[id]/output-stats
tcaEquipmentSpeed
Fault Code: F40574
Message
Threshold Crossed: equipment:NetworkElementFanStats property: speed
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentSpeed
moClass: equipment:NetworkElementFanStats
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]/stats
Affected MO: sys/fex-[id]/fan-[id]/stats
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]/stats
Affected MO: sys/switch-[id]/fan-[id]/stats
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]/stats
tcaEquipmentSpeedMin
Fault Code: F40576
Message
Threshold Crossed: equipment:NetworkElementFanStats property: speedMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentSpeedMin
moClass: equipment:NetworkElementFanStats
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]/stats
Affected MO: sys/fex-[id]/fan-[id]/stats
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]/stats
Affected MO: sys/switch-[id]/fan-[id]/stats
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]/stats
tcaEquipmentSpeedMax
Fault Code: F40577
Message
Threshold Crossed: equipment:NetworkElementFanStats property: speedMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentSpeedMax
moClass: equipment:NetworkElementFanStats
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]/stats
Affected MO: sys/fex-[id]/fan-[id]/stats
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]/stats
Affected MO: sys/switch-[id]/fan-[id]/stats
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]/stats
tcaEquipmentSpeedAvg
Fault Code: F40578
Message
Threshold Crossed: equipment:NetworkElementFanStats property: speedAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentSpeedAvg
moClass: equipment:NetworkElementFanStats
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]/stats
Affected MO: sys/fex-[id]/fan-[id]/stats
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]/stats
Affected MO: sys/switch-[id]/fan-[id]/stats
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]/stats
tcaEquipmentDrivePercentage
Fault Code: F40582
Message
Threshold Crossed: equipment:NetworkElementFanStats property: drivePercentage
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentDrivePercentage
moClass: equipment:NetworkElementFanStats
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]/stats
Affected MO: sys/fex-[id]/fan-[id]/stats
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]/stats
Affected MO: sys/switch-[id]/fan-[id]/stats
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]/stats
tcaEquipmentDrivePercentageMin
Fault Code: F40584
Message
Threshold Crossed: equipment:NetworkElementFanStats property: drivePercentageMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentDrivePercentageMin
moClass: equipment:NetworkElementFanStats
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]/stats
Affected MO: sys/fex-[id]/fan-[id]/stats
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]/stats
Affected MO: sys/switch-[id]/fan-[id]/stats
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]/stats
tcaEquipmentDrivePercentageMax
Fault Code: F40585
Message
Threshold Crossed: equipment:NetworkElementFanStats property: drivePercentageMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentDrivePercentageMax
moClass: equipment:NetworkElementFanStats
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]/stats
Affected MO: sys/fex-[id]/fan-[id]/stats
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]/stats
Affected MO: sys/switch-[id]/fan-[id]/stats
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]/stats
tcaEquipmentDrivePercentageAvg
Fault Code: F40586
Message
Threshold Crossed: equipment:NetworkElementFanStats property: drivePercentageAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentDrivePercentageAvg
moClass: equipment:NetworkElementFanStats
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]/stats
Affected MO: sys/fex-[id]/fan-[id]/stats
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]/stats
Affected MO: sys/switch-[id]/fan-[id]/stats
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]/stats
tcaSwSlotOutlet1
Fault Code: F41199
Message
Threshold Crossed: sw:CardEnvStats property: SlotOutlet1
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwSlotOutlet1
Affected MO: sys/switch-[id]/cardenvstats
tcaSwSlotOutlet1Min
Fault Code: F41201
Message
Threshold Crossed: sw:CardEnvStats property: SlotOutlet1Min
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwSlotOutlet1Min
Affected MO: sys/switch-[id]/cardenvstats
tcaSwSlotOutlet1Max
Fault Code: F41202
Message
Threshold Crossed: sw:CardEnvStats property: SlotOutlet1Max
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwSlotOutlet1Max
Affected MO: sys/switch-[id]/cardenvstats
tcaSwSlotOutlet1Avg
Fault Code: F41203
Message
Threshold Crossed: sw:CardEnvStats property: SlotOutlet1Avg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwSlotOutlet1Avg
Affected MO: sys/switch-[id]/cardenvstats
tcaSwSlotOutlet2
Fault Code: F41207
Message
Threshold Crossed: sw:CardEnvStats property: SlotOutlet2
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwSlotOutlet2
Affected MO: sys/switch-[id]/cardenvstats
tcaSwSlotOutlet2Min
Fault Code: F41209
Message
Threshold Crossed: sw:CardEnvStats property: SlotOutlet2Min
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwSlotOutlet2Min
Affected MO: sys/switch-[id]/cardenvstats
tcaSwSlotOutlet2Max
Fault Code: F41210
Message
Threshold Crossed: sw:CardEnvStats property: SlotOutlet2Max
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwSlotOutlet2Max
Affected MO: sys/switch-[id]/cardenvstats
tcaSwSlotOutlet2Avg
Fault Code: F41211
Message
Threshold Crossed: sw:CardEnvStats property: SlotOutlet2Avg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwSlotOutlet2Avg
Affected MO: sys/switch-[id]/cardenvstats
tcaSwSlotOutlet3
Fault Code: F41215
Message
Threshold Crossed: sw:CardEnvStats property: SlotOutlet3
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwSlotOutlet3
Affected MO: sys/switch-[id]/cardenvstats
tcaSwSlotOutlet3Min
Fault Code: F41217
Message
Threshold Crossed: sw:CardEnvStats property: SlotOutlet3Min
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwSlotOutlet3Min
Affected MO: sys/switch-[id]/cardenvstats
tcaSwSlotOutlet3Max
Fault Code: F41218
Message
Threshold Crossed: sw:CardEnvStats property: SlotOutlet3Max
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwSlotOutlet3Max
Affected MO: sys/switch-[id]/cardenvstats
tcaSwSlotOutlet3Avg
Fault Code: F41219
Message
Threshold Crossed: sw:CardEnvStats property: SlotOutlet3Avg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwSlotOutlet3Avg
Affected MO: sys/switch-[id]/cardenvstats
tcaEtherPacketsTxDelta
Fault Code: F41289
Message
Threshold Crossed: ether:FcoeInterfaceStats property: packetsTxDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherPacketsTxDelta
moClass: ether:FcoeInterfaceStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
tcaEtherPacketsTxDeltaMin
Fault Code: F41290
Message
Threshold Crossed: ether:FcoeInterfaceStats property: packetsTxDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherPacketsTxDeltaMin
moClass: ether:FcoeInterfaceStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
tcaEtherPacketsTxDeltaMax
Fault Code: F41291
Message
Threshold Crossed: ether:FcoeInterfaceStats property: packetsTxDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherPacketsTxDeltaMax
moClass: ether:FcoeInterfaceStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
tcaEtherPacketsTxDeltaAvg
Fault Code: F41292
Message
Threshold Crossed: ether:FcoeInterfaceStats property: packetsTxDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherPacketsTxDeltaAvg
moClass: ether:FcoeInterfaceStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
tcaEtherPacketsRxDelta
Fault Code: F41299
Message
Threshold Crossed: ether:FcoeInterfaceStats property: packetsRxDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherPacketsRxDelta
moClass: ether:FcoeInterfaceStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
tcaEtherPacketsRxDeltaMin
Fault Code: F41300
Message
Threshold Crossed: ether:FcoeInterfaceStats property: packetsRxDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherPacketsRxDeltaMin
moClass: ether:FcoeInterfaceStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
tcaEtherPacketsRxDeltaMax
Fault Code: F41301
Message
Threshold Crossed: ether:FcoeInterfaceStats property: packetsRxDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherPacketsRxDeltaMax
moClass: ether:FcoeInterfaceStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
tcaEtherPacketsRxDeltaAvg
Fault Code: F41302
Message
Threshold Crossed: ether:FcoeInterfaceStats property: packetsRxDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherPacketsRxDeltaAvg
moClass: ether:FcoeInterfaceStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
tcaEtherBytesTxDelta
Fault Code: F41309
Message
Threshold Crossed: ether:FcoeInterfaceStats property: bytesTxDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherBytesTxDelta
moClass: ether:FcoeInterfaceStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
tcaEtherBytesTxDeltaMin
Fault Code: F41310
Message
Threshold Crossed: ether:FcoeInterfaceStats property: bytesTxDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherBytesTxDeltaMin
moClass: ether:FcoeInterfaceStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
tcaEtherBytesTxDeltaMax
Fault Code: F41311
Message
Threshold Crossed: ether:FcoeInterfaceStats property: bytesTxDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherBytesTxDeltaMax
moClass: ether:FcoeInterfaceStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
tcaEtherBytesTxDeltaAvg
Fault Code: F41312
Message
Threshold Crossed: ether:FcoeInterfaceStats property: bytesTxDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherBytesTxDeltaAvg
moClass: ether:FcoeInterfaceStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
tcaEtherBytesRxDelta
Fault Code: F41319
Message
Threshold Crossed: ether:FcoeInterfaceStats property: bytesRxDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherBytesRxDelta
moClass: ether:FcoeInterfaceStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
tcaEtherBytesRxDeltaMin
Fault Code: F41320
Message
Threshold Crossed: ether:FcoeInterfaceStats property: bytesRxDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherBytesRxDeltaMin
moClass: ether:FcoeInterfaceStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
tcaEtherBytesRxDeltaMax
Fault Code: F41321
Message
Threshold Crossed: ether:FcoeInterfaceStats property: bytesRxDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherBytesRxDeltaMax
moClass: ether:FcoeInterfaceStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
tcaEtherBytesRxDeltaAvg
Fault Code: F41322
Message
Threshold Crossed: ether:FcoeInterfaceStats property: bytesRxDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherBytesRxDeltaAvg
moClass: ether:FcoeInterfaceStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
tcaEtherErrorsTxDelta
Fault Code: F41329
Message
Threshold Crossed: ether:FcoeInterfaceStats property: errorsTxDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherErrorsTxDelta
moClass: ether:FcoeInterfaceStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
tcaEtherErrorsTxDeltaMin
Fault Code: F41330
Message
Threshold Crossed: ether:FcoeInterfaceStats property: errorsTxDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherErrorsTxDeltaMin
moClass: ether:FcoeInterfaceStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
tcaEtherErrorsTxDeltaMax
Fault Code: F41331
Message
Threshold Crossed: ether:FcoeInterfaceStats property: errorsTxDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherErrorsTxDeltaMax
moClass: ether:FcoeInterfaceStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
tcaEtherErrorsTxDeltaAvg
Fault Code: F41332
Message
Threshold Crossed: ether:FcoeInterfaceStats property: errorsTxDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherErrorsTxDeltaAvg
moClass: ether:FcoeInterfaceStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
tcaEtherErrorsRxDelta
Fault Code: F41339
Message
Threshold Crossed: ether:FcoeInterfaceStats property: errorsRxDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherErrorsRxDelta
moClass: ether:FcoeInterfaceStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
tcaEtherErrorsRxDeltaMin
Fault Code: F41340
Message
Threshold Crossed: ether:FcoeInterfaceStats property: errorsRxDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherErrorsRxDeltaMin
moClass: ether:FcoeInterfaceStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
tcaEtherErrorsRxDeltaMax
Fault Code: F41341
Message
Threshold Crossed: ether:FcoeInterfaceStats property: errorsRxDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherErrorsRxDeltaMax
moClass: ether:FcoeInterfaceStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
tcaEtherErrorsRxDeltaAvg
Fault Code: F41342
Message
Threshold Crossed: ether:FcoeInterfaceStats property: errorsRxDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherErrorsRxDeltaAvg
moClass: ether:FcoeInterfaceStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
tcaEtherDroppedTxDelta
Fault Code: F41349
Message
Threshold Crossed: ether:FcoeInterfaceStats property: droppedTxDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherDroppedTxDelta
moClass: ether:FcoeInterfaceStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
tcaEtherDroppedTxDeltaMin
Fault Code: F41350
Message
Threshold Crossed: ether:FcoeInterfaceStats property: droppedTxDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherDroppedTxDeltaMin
moClass: ether:FcoeInterfaceStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
tcaEtherDroppedTxDeltaMax
Fault Code: F41351
Message
Threshold Crossed: ether:FcoeInterfaceStats property: droppedTxDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherDroppedTxDeltaMax
moClass: ether:FcoeInterfaceStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
tcaEtherDroppedTxDeltaAvg
Fault Code: F41352
Message
Threshold Crossed: ether:FcoeInterfaceStats property: droppedTxDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherDroppedTxDeltaAvg
moClass: ether:FcoeInterfaceStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
tcaEtherDroppedRxDelta
Fault Code: F41359
Message
Threshold Crossed: ether:FcoeInterfaceStats property: droppedRxDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherDroppedRxDelta
moClass: ether:FcoeInterfaceStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
tcaEtherDroppedRxDeltaMin
Fault Code: F41360
Message
Threshold Crossed: ether:FcoeInterfaceStats property: droppedRxDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherDroppedRxDeltaMin
moClass: ether:FcoeInterfaceStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
tcaEtherDroppedRxDeltaMax
Fault Code: F41361
Message
Threshold Crossed: ether:FcoeInterfaceStats property: droppedRxDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherDroppedRxDeltaMax
moClass: ether:FcoeInterfaceStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
tcaEtherDroppedRxDeltaAvg
Fault Code: F41362
Message
Threshold Crossed: ether:FcoeInterfaceStats property: droppedRxDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherDroppedRxDeltaAvg
moClass: ether:FcoeInterfaceStats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/fc-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-slot-[slotId]-port-[portId]/fcoe-interface-stats
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]/fcoe-interface-stats
tcaEtherFrameTxDelta
Fault Code: F43294
Message
Threshold Crossed: ether:NiErrStats property: frameTxDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherFrameTxDelta
moClass: ether:NiErrStats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
tcaEtherFrameTxDeltaMin
Fault Code: F43295
Message
Threshold Crossed: ether:NiErrStats property: frameTxDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherFrameTxDeltaMin
moClass: ether:NiErrStats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
tcaEtherFrameTxDeltaMax
Fault Code: F43296
Message
Threshold Crossed: ether:NiErrStats property: frameTxDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherFrameTxDeltaMax
moClass: ether:NiErrStats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
tcaEtherFrameTxDeltaAvg
Fault Code: F43297
Message
Threshold Crossed: ether:NiErrStats property: frameTxDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherFrameTxDeltaAvg
moClass: ether:NiErrStats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
tcaEtherTooLongDelta
Fault Code: F43304
Message
Threshold Crossed: ether:NiErrStats property: tooLongDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherTooLongDelta
moClass: ether:NiErrStats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
tcaEtherTooLongDeltaMin
Fault Code: F43305
Message
Threshold Crossed: ether:NiErrStats property: tooLongDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherTooLongDeltaMin
moClass: ether:NiErrStats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
tcaEtherTooLongDeltaMax
Fault Code: F43306
Message
Threshold Crossed: ether:NiErrStats property: tooLongDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherTooLongDeltaMax
moClass: ether:NiErrStats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
tcaEtherTooLongDeltaAvg
Fault Code: F43307
Message
Threshold Crossed: ether:NiErrStats property: tooLongDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherTooLongDeltaAvg
moClass: ether:NiErrStats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
tcaEtherTooShortDelta
Fault Code: F43314
Message
Threshold Crossed: ether:NiErrStats property: tooShortDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherTooShortDelta
moClass: ether:NiErrStats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
tcaEtherTooShortDeltaMin
Fault Code: F43315
Message
Threshold Crossed: ether:NiErrStats property: tooShortDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherTooShortDeltaMin
moClass: ether:NiErrStats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
tcaEtherTooShortDeltaMax
Fault Code: F43316
Message
Threshold Crossed: ether:NiErrStats property: tooShortDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherTooShortDeltaMax
moClass: ether:NiErrStats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
tcaEtherTooShortDeltaAvg
Fault Code: F43317
Message
Threshold Crossed: ether:NiErrStats property: tooShortDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherTooShortDeltaAvg
moClass: ether:NiErrStats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
tcaEtherCrcDelta
Fault Code: F43324
Message
Threshold Crossed: ether:NiErrStats property: crcDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherCrcDelta
moClass: ether:NiErrStats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
tcaEtherCrcDeltaMin
Fault Code: F43325
Message
Threshold Crossed: ether:NiErrStats property: crcDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherCrcDeltaMin
moClass: ether:NiErrStats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
tcaEtherCrcDeltaMax
Fault Code: F43326
Message
Threshold Crossed: ether:NiErrStats property: crcDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherCrcDeltaMax
moClass: ether:NiErrStats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
tcaEtherCrcDeltaAvg
Fault Code: F43327
Message
Threshold Crossed: ether:NiErrStats property: crcDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherCrcDeltaAvg
moClass: ether:NiErrStats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
tcaEtherInRangeDelta
Fault Code: F43334
Message
Threshold Crossed: ether:NiErrStats property: inRangeDelta
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherInRangeDelta
moClass: ether:NiErrStats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
tcaEtherInRangeDeltaMin
Fault Code: F43335
Message
Threshold Crossed: ether:NiErrStats property: inRangeDeltaMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherInRangeDeltaMin
moClass: ether:NiErrStats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
tcaEtherInRangeDeltaMax
Fault Code: F43336
Message
Threshold Crossed: ether:NiErrStats property: inRangeDeltaMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherInRangeDeltaMax
moClass: ether:NiErrStats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
tcaEtherInRangeDeltaAvg
Fault Code: F43337
Message
Threshold Crossed: ether:NiErrStats property: inRangeDeltaAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEtherInRangeDeltaAvg
moClass: ether:NiErrStats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/slot-[id]/shared-io-module/[type]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/pc-[portId]/ni-err-stats
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/ni-err-stats
tcaEquipmentProcTemp
Fault Code: F44131
Message
Threshold Crossed: equipment:IOCardStats property: procTemp
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentProcTemp
moClass: equipment:IOCardStats
Affected MO: sys/chassis-[id]/slot-[id]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/stats
Affected MO: sys/fex-[id]/slot-[id]/stats
tcaEquipmentProcTempMin
Fault Code: F44133
Message
Threshold Crossed: equipment:IOCardStats property: procTempMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentProcTempMin
moClass: equipment:IOCardStats
Affected MO: sys/chassis-[id]/slot-[id]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/stats
Affected MO: sys/fex-[id]/slot-[id]/stats
tcaEquipmentProcTempMax
Fault Code: F44134
Message
Threshold Crossed: equipment:IOCardStats property: procTempMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentProcTempMax
moClass: equipment:IOCardStats
Affected MO: sys/chassis-[id]/slot-[id]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/stats
Affected MO: sys/fex-[id]/slot-[id]/stats
tcaEquipmentProcTempAvg
Fault Code: F44135
Message
Threshold Crossed: equipment:IOCardStats property: procTempAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentProcTempAvg
moClass: equipment:IOCardStats
Affected MO: sys/chassis-[id]/slot-[id]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/stats
Affected MO: sys/fex-[id]/slot-[id]/stats
tcaEquipmentDimmTemp
Fault Code: F44139
Message
Threshold Crossed: equipment:IOCardStats property: dimmTemp
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentDimmTemp
moClass: equipment:IOCardStats
Affected MO: sys/chassis-[id]/slot-[id]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/stats
Affected MO: sys/fex-[id]/slot-[id]/stats
tcaEquipmentDimmTempMin
Fault Code: F44141
Message
Threshold Crossed: equipment:IOCardStats property: dimmTempMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentDimmTempMin
moClass: equipment:IOCardStats
Affected MO: sys/chassis-[id]/slot-[id]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/stats
Affected MO: sys/fex-[id]/slot-[id]/stats
tcaEquipmentDimmTempMax
Fault Code: F44142
Message
Threshold Crossed: equipment:IOCardStats property: dimmTempMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentDimmTempMax
moClass: equipment:IOCardStats
Affected MO: sys/chassis-[id]/slot-[id]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/stats
Affected MO: sys/fex-[id]/slot-[id]/stats
tcaEquipmentDimmTempAvg
Fault Code: F44143
Message
Threshold Crossed: equipment:IOCardStats property: dimmTempAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentDimmTempAvg
moClass: equipment:IOCardStats
Affected MO: sys/chassis-[id]/slot-[id]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/stats
Affected MO: sys/fex-[id]/slot-[id]/stats
tcaStorageTemperature
Fault Code: F44217
Message
Threshold Crossed: storage:DiskEnvStats property: temperature
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStorageTemperature
moClass: storage:DiskEnvStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/disk-env-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/disk-env-stats
tcaStorageTemperatureMin
Fault Code: F44219
Message
Threshold Crossed: storage:DiskEnvStats property: temperatureMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStorageTemperatureMin
moClass: storage:DiskEnvStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/disk-env-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/disk-env-stats
tcaStorageTemperatureMax
Fault Code: F44220
Message
Threshold Crossed: storage:DiskEnvStats property: temperatureMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStorageTemperatureMax
moClass: storage:DiskEnvStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/disk-env-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/disk-env-stats
tcaStorageTemperatureAvg
Fault Code: F44221
Message
Threshold Crossed: storage:DiskEnvStats property: temperatureAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStorageTemperatureAvg
moClass: storage:DiskEnvStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/disk-env-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/disk-env-stats
tcaStorageWearPercentage
Fault Code: F44225
Message
Threshold Crossed: storage:DiskEnvStats property: wearPercentage
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStorageWearPercentage
moClass: storage:DiskEnvStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/disk-env-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/disk-env-stats
tcaStorageWearPercentageMin
Fault Code: F44227
Message
Threshold Crossed: storage:DiskEnvStats property: wearPercentageMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStorageWearPercentageMin
moClass: storage:DiskEnvStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/disk-env-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/disk-env-stats
tcaStorageWearPercentageMax
Fault Code: F44228
Message
Threshold Crossed: storage:DiskEnvStats property: wearPercentageMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStorageWearPercentageMax
moClass: storage:DiskEnvStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/disk-env-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/disk-env-stats
tcaStorageWearPercentageAvg
Fault Code: F44229
Message
Threshold Crossed: storage:DiskEnvStats property: wearPercentageAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStorageWearPercentageAvg
moClass: storage:DiskEnvStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/disk-env-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/disk-env-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/disk-env-stats
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/disk-env-stats
tcaEquipmentInputPower
Fault Code: F44564
Message
Threshold Crossed: equipment:PsuStats property: inputPower
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentInputPower
moClass: equipment:PsuStats
Affected MO: sys/chassis-[id]/psu-[id]/stats
Affected MO: sys/fex-[id]/psu-[id]/stats
Affected MO: sys/rack-unit-[id]/psu-[id]/stats
Affected MO: sys/switch-[id]/psu-[id]/stats
tcaEquipmentInputPowerMin
Fault Code: F44566
Message
Threshold Crossed: equipment:PsuStats property: inputPowerMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentInputPowerMin
moClass: equipment:PsuStats
Affected MO: sys/chassis-[id]/psu-[id]/stats
Affected MO: sys/fex-[id]/psu-[id]/stats
Affected MO: sys/rack-unit-[id]/psu-[id]/stats
Affected MO: sys/switch-[id]/psu-[id]/stats
tcaEquipmentInputPowerMax
Fault Code: F44567
Message
Threshold Crossed: equipment:PsuStats property: inputPowerMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentInputPowerMax
moClass: equipment:PsuStats
Affected MO: sys/chassis-[id]/psu-[id]/stats
Affected MO: sys/fex-[id]/psu-[id]/stats
Affected MO: sys/rack-unit-[id]/psu-[id]/stats
Affected MO: sys/switch-[id]/psu-[id]/stats
tcaEquipmentInputPowerAvg
Fault Code: F44568
Message
Threshold Crossed: equipment:PsuStats property: inputPowerAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentInputPowerAvg
moClass: equipment:PsuStats
Affected MO: sys/chassis-[id]/psu-[id]/stats
Affected MO: sys/fex-[id]/psu-[id]/stats
Affected MO: sys/rack-unit-[id]/psu-[id]/stats
Affected MO: sys/switch-[id]/psu-[id]/stats
tcaEquipmentChassisI2CErrors
Fault Code: F44728
Message
Threshold Crossed: equipment:ChassisStats property: ChassisI2CErrors
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentChassisI2CErrors
moClass: equipment:ChassisStats
Affected MO: sys/chassis-[id]/stats
tcaEquipmentIomI2CErrors
Fault Code: F44738
Message
Threshold Crossed: equipment:IOCardStats property: IomI2CErrors
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentIomI2CErrors
moClass: equipment:IOCardStats
Affected MO: sys/chassis-[id]/slot-[id]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/stats
Affected MO: sys/fex-[id]/slot-[id]/stats
tcaEquipmentPsuI2CErrors
Fault Code: F44748
Message
Threshold Crossed: equipment:PsuStats property: PsuI2CErrors
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentPsuI2CErrors
moClass: equipment:PsuStats
Affected MO: sys/chassis-[id]/psu-[id]/stats
Affected MO: sys/fex-[id]/psu-[id]/stats
Affected MO: sys/rack-unit-[id]/psu-[id]/stats
Affected MO: sys/switch-[id]/psu-[id]/stats
tcaSwDonner
Fault Code: F45019
Message
Threshold Crossed: sw:EnvStats property: donner
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwDonner
Affected MO: sys/switch-[id]/envstats
tcaSwDonnerMin
Fault Code: F45021
Message
Threshold Crossed: sw:EnvStats property: donnerMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwDonnerMin
Affected MO: sys/switch-[id]/envstats
tcaSwDonnerMax
Fault Code: F45022
Message
Threshold Crossed: sw:EnvStats property: donnerMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwDonnerMax
Affected MO: sys/switch-[id]/envstats
tcaSwDonnerAvg
Fault Code: F45023
Message
Threshold Crossed: sw:EnvStats property: donnerAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwDonnerAvg
Affected MO: sys/switch-[id]/envstats
tcaSwTd2
Fault Code: F45027
Message
Threshold Crossed: sw:EnvStats property: td2
Explanation
Recommended Action
Fault Details
Affected MO: sys/switch-[id]/envstats
tcaSwTd2Min
Fault Code: F45029
Message
Threshold Crossed: sw:EnvStats property: td2Min
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwTd2Min
Affected MO: sys/switch-[id]/envstats
tcaSwTd2Max
Fault Code: F45030
Message
Threshold Crossed: sw:EnvStats property: td2Max
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwTd2Max
Affected MO: sys/switch-[id]/envstats
tcaSwTd2Avg
Fault Code: F45031
Message
Threshold Crossed: sw:EnvStats property: td2Avg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwTd2Avg
Affected MO: sys/switch-[id]/envstats
tcaSwTiburon
Fault Code: F45035
Message
Threshold Crossed: sw:EnvStats property: tiburon
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwTiburon
Affected MO: sys/switch-[id]/envstats
tcaSwTiburonMin
Fault Code: F45037
Message
Threshold Crossed: sw:EnvStats property: tiburonMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwTiburonMin
Affected MO: sys/switch-[id]/envstats
tcaSwTiburonMax
Fault Code: F45038
Message
Threshold Crossed: sw:EnvStats property: tiburonMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwTiburonMax
Affected MO: sys/switch-[id]/envstats
tcaSwTiburonAvg
Fault Code: F45039
Message
Threshold Crossed: sw:EnvStats property: tiburonAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwTiburonAvg
Affected MO: sys/switch-[id]/envstats
tcaSwKernelMemTotal
Fault Code: F45043
Message
Threshold Crossed: sw:SystemStats property: kernelMemTotal
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwKernelMemTotal
Affected MO: sys/switch-[id]/sysstats
tcaSwKernelMemTotalMin
Fault Code: F45045
Message
Threshold Crossed: sw:SystemStats property: kernelMemTotalMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwKernelMemTotalMin
Affected MO: sys/switch-[id]/sysstats
tcaSwKernelMemTotalMax
Fault Code: F45046
Message
Threshold Crossed: sw:SystemStats property: kernelMemTotalMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwKernelMemTotalMax
Affected MO: sys/switch-[id]/sysstats
tcaSwKernelMemTotalAvg
Fault Code: F45047
Message
Threshold Crossed: sw:SystemStats property: kernelMemTotalAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwKernelMemTotalAvg
Affected MO: sys/switch-[id]/sysstats
tcaSwKernelMemFree
Fault Code: F45051
Message
Threshold Crossed: sw:SystemStats property: kernelMemFree
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwKernelMemFree
Affected MO: sys/switch-[id]/sysstats
tcaSwKernelMemFreeMin
Fault Code: F45053
Message
Threshold Crossed: sw:SystemStats property: kernelMemFreeMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwKernelMemFreeMin
Affected MO: sys/switch-[id]/sysstats
tcaSwKernelMemFreeMax
Fault Code: F45054
Message
Threshold Crossed: sw:SystemStats property: kernelMemFreeMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwKernelMemFreeMax
Affected MO: sys/switch-[id]/sysstats
tcaSwKernelMemFreeAvg
Fault Code: F45055
Message
Threshold Crossed: sw:SystemStats property: kernelMemFreeAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwKernelMemFreeAvg
Affected MO: sys/switch-[id]/sysstats
tcaEquipmentMemAvailable
Fault Code: F45154
Message
Threshold Crossed: equipment:FexSystemStats property: memAvailable
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentMemAvailable
moClass: equipment:FexSystemStats
Affected MO: sys/fex-[id]/sys-stats
tcaEquipmentMemAvailableMin
Fault Code: F45156
Message
Threshold Crossed: equipment:FexSystemStats property: memAvailableMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentMemAvailableMin
moClass: equipment:FexSystemStats
Affected MO: sys/fex-[id]/sys-stats
tcaEquipmentMemAvailableMax
Fault Code: F45157
Message
Threshold Crossed: equipment:FexSystemStats property: memAvailableMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentMemAvailableMax
moClass: equipment:FexSystemStats
Affected MO: sys/fex-[id]/sys-stats
tcaEquipmentMemAvailableAvg
Fault Code: F45158
Message
Threshold Crossed: equipment:FexSystemStats property: memAvailableAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentMemAvailableAvg
moClass: equipment:FexSystemStats
Affected MO: sys/fex-[id]/sys-stats
tcaEquipmentMemCached
Fault Code: F45162
Message
Threshold Crossed: equipment:FexSystemStats property: memCached
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentMemCached
moClass: equipment:FexSystemStats
Affected MO: sys/fex-[id]/sys-stats
tcaEquipmentMemCachedMin
Fault Code: F45164
Message
Threshold Crossed: equipment:FexSystemStats property: memCachedMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentMemCachedMin
moClass: equipment:FexSystemStats
Affected MO: sys/fex-[id]/sys-stats
tcaEquipmentMemCachedMax
Fault Code: F45165
Message
Threshold Crossed: equipment:FexSystemStats property: memCachedMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentMemCachedMax
moClass: equipment:FexSystemStats
Affected MO: sys/fex-[id]/sys-stats
tcaEquipmentMemCachedAvg
Fault Code: F45166
Message
Threshold Crossed: equipment:FexSystemStats property: memCachedAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentMemCachedAvg
moClass: equipment:FexSystemStats
Affected MO: sys/fex-[id]/sys-stats
tcaEquipmentLoad
Fault Code: F45170
Message
Threshold Crossed: equipment:FexSystemStats property: load
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentLoad
moClass: equipment:FexSystemStats
Affected MO: sys/fex-[id]/sys-stats
tcaEquipmentLoadMin
Fault Code: F45172
Message
Threshold Crossed: equipment:FexSystemStats property: loadMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentLoadMin
moClass: equipment:FexSystemStats
Affected MO: sys/fex-[id]/sys-stats
tcaEquipmentLoadMax
Fault Code: F45173
Message
Threshold Crossed: equipment:FexSystemStats property: loadMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentLoadMax
moClass: equipment:FexSystemStats
Affected MO: sys/fex-[id]/sys-stats
tcaEquipmentLoadAvg
Fault Code: F45174
Message
Threshold Crossed: equipment:FexSystemStats property: loadAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentLoadAvg
moClass: equipment:FexSystemStats
Affected MO: sys/fex-[id]/sys-stats
tcaEquipmentKernelMemTotal
Fault Code: F45178
Message
Threshold Crossed: equipment:FexSystemStats property: kernelMemTotal
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentKernelMemTotal
moClass: equipment:FexSystemStats
Affected MO: sys/fex-[id]/sys-stats
tcaEquipmentKernelMemTotalMin
Fault Code: F45180
Message
Threshold Crossed: equipment:FexSystemStats property: kernelMemTotalMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentKernelMemTotalMin
moClass: equipment:FexSystemStats
Affected MO: sys/fex-[id]/sys-stats
tcaEquipmentKernelMemTotalMax
Fault Code: F45181
Message
Threshold Crossed: equipment:FexSystemStats property: kernelMemTotalMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentKernelMemTotalMax
moClass: equipment:FexSystemStats
Affected MO: sys/fex-[id]/sys-stats
tcaEquipmentKernelMemTotalAvg
Fault Code: F45182
Message
Threshold Crossed: equipment:FexSystemStats property: kernelMemTotalAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentKernelMemTotalAvg
moClass: equipment:FexSystemStats
Affected MO: sys/fex-[id]/sys-stats
tcaEquipmentKernelMemFree
Fault Code: F45186
Message
Threshold Crossed: equipment:FexSystemStats property: kernelMemFree
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentKernelMemFree
moClass: equipment:FexSystemStats
Affected MO: sys/fex-[id]/sys-stats
tcaEquipmentKernelMemFreeMin
Fault Code: F45188
Message
Threshold Crossed: equipment:FexSystemStats property: kernelMemFreeMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentKernelMemFreeMin
moClass: equipment:FexSystemStats
Affected MO: sys/fex-[id]/sys-stats
tcaEquipmentKernelMemFreeMax
Fault Code: F45189
Message
Threshold Crossed: equipment:FexSystemStats property: kernelMemFreeMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentKernelMemFreeMax
moClass: equipment:FexSystemStats
Affected MO: sys/fex-[id]/sys-stats
tcaEquipmentKernelMemFreeAvg
Fault Code: F45190
Message
Threshold Crossed: equipment:FexSystemStats property: kernelMemFreeAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentKernelMemFreeAvg
moClass: equipment:FexSystemStats
Affected MO: sys/fex-[id]/sys-stats
tcaSwCorrectableParityError
Fault Code: F45211
Message
Threshold Crossed: sw:SystemStats property: CorrectableParityError
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwCorrectableParityError
Affected MO: sys/switch-[id]/sysstats
tcaSwCorrectableParityErrorMin
Fault Code: F45213
Message
Threshold Crossed: sw:SystemStats property: CorrectableParityErrorMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwCorrectableParityErrorMin
Affected MO: sys/switch-[id]/sysstats
tcaSwCorrectableParityErrorMax
Fault Code: F45214
Message
Threshold Crossed: sw:SystemStats property: CorrectableParityErrorMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwCorrectableParityErrorMax
Affected MO: sys/switch-[id]/sysstats
tcaSwCorrectableParityErrorAvg
Fault Code: F45215
Message
Threshold Crossed: sw:SystemStats property: CorrectableParityErrorAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaSwCorrectableParityErrorAvg
Affected MO: sys/switch-[id]/sysstats
tcaEquipmentChassisI2CErrorsMin
Fault Code: F45266
Message
Threshold Crossed: equipment:ChassisStats property: ChassisI2CErrorsMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentChassisI2CErrorsMin
moClass: equipment:ChassisStats
Affected MO: sys/chassis-[id]/stats
tcaEquipmentChassisI2CErrorsMax
Fault Code: F45267
Message
Threshold Crossed: equipment:ChassisStats property: ChassisI2CErrorsMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentChassisI2CErrorsMax
moClass: equipment:ChassisStats
Affected MO: sys/chassis-[id]/stats
tcaEquipmentChassisI2CErrorsAvg
Fault Code: F45268
Message
Threshold Crossed: equipment:ChassisStats property: ChassisI2CErrorsAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentChassisI2CErrorsAvg
moClass: equipment:ChassisStats
Affected MO: sys/chassis-[id]/stats
tcaEquipmentIomI2CErrorsMin
Fault Code: F45272
Message
Threshold Crossed: equipment:IOCardStats property: IomI2CErrorsMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentIomI2CErrorsMin
moClass: equipment:IOCardStats
Affected MO: sys/chassis-[id]/slot-[id]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/stats
Affected MO: sys/fex-[id]/slot-[id]/stats
tcaEquipmentIomI2CErrorsMax
Fault Code: F45273
Message
Threshold Crossed: equipment:IOCardStats property: IomI2CErrorsMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentIomI2CErrorsMax
moClass: equipment:IOCardStats
Affected MO: sys/chassis-[id]/slot-[id]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/stats
Affected MO: sys/fex-[id]/slot-[id]/stats
tcaEquipmentIomI2CErrorsAvg
Fault Code: F45274
Message
Threshold Crossed: equipment:IOCardStats property: IomI2CErrorsAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentIomI2CErrorsAvg
moClass: equipment:IOCardStats
Affected MO: sys/chassis-[id]/slot-[id]/stats
Affected MO: sys/chassis-[id]/sw-slot-[id]/stats
Affected MO: sys/fex-[id]/slot-[id]/stats
tcaEquipmentPsuI2CErrorsMin
Fault Code: F45278
Message
Threshold Crossed: equipment:PsuStats property: PsuI2CErrorsMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentPsuI2CErrorsMin
moClass: equipment:PsuStats
Affected MO: sys/chassis-[id]/psu-[id]/stats
Affected MO: sys/fex-[id]/psu-[id]/stats
Affected MO: sys/rack-unit-[id]/psu-[id]/stats
Affected MO: sys/switch-[id]/psu-[id]/stats
tcaEquipmentPsuI2CErrorsMax
Fault Code: F45279
Message
Threshold Crossed: equipment:PsuStats property: PsuI2CErrorsMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentPsuI2CErrorsMax
moClass: equipment:PsuStats
Affected MO: sys/chassis-[id]/psu-[id]/stats
Affected MO: sys/fex-[id]/psu-[id]/stats
Affected MO: sys/rack-unit-[id]/psu-[id]/stats
Affected MO: sys/switch-[id]/psu-[id]/stats
tcaEquipmentPsuI2CErrorsAvg
Fault Code: F45280
Message
Threshold Crossed: equipment:PsuStats property: PsuI2CErrorsAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentPsuI2CErrorsAvg
moClass: equipment:PsuStats
Affected MO: sys/chassis-[id]/psu-[id]/stats
Affected MO: sys/fex-[id]/psu-[id]/stats
Affected MO: sys/rack-unit-[id]/psu-[id]/stats
Affected MO: sys/switch-[id]/psu-[id]/stats
tcaEquipmentFanModuleI2CErrors
Fault Code: F45284
Message
Threshold Crossed: equipment:FanModuleStats property: FanModuleI2CErrors
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentFanModuleI2CErrors
moClass: equipment:FanModuleStats
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/stats
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/stats
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/stats
tcaEquipmentFanModuleI2CErrorsMin
Fault Code: F45286
Message
Threshold Crossed: equipment:FanModuleStats property: FanModuleI2CErrorsMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentFanModuleI2CErrorsMin
moClass: equipment:FanModuleStats
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/stats
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/stats
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/stats
tcaEquipmentFanModuleI2CErrorsMax
Fault Code: F45287
Message
Threshold Crossed: equipment:FanModuleStats property: FanModuleI2CErrorsMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentFanModuleI2CErrorsMax
moClass: equipment:FanModuleStats
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/stats
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/stats
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/stats
tcaEquipmentFanModuleI2CErrorsAvg
Fault Code: F45288
Message
Threshold Crossed: equipment:FanModuleStats property: FanModuleI2CErrorsAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentFanModuleI2CErrorsAvg
moClass: equipment:FanModuleStats
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/stats
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/stats
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/stats
tcaStorageRightInletTemp
Fault Code: F45374
Message
Threshold Crossed: storage:HddMotherBoardTempStats property: rightInletTemp
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStorageRightInletTemp
moClass: storage:HddMotherBoardTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/rack-unit-[id]/enc-[id]/hdd-mobo-temp-stats
tcaStorageRightInletTempMin
Fault Code: F45376
Message
Threshold Crossed: storage:HddMotherBoardTempStats property: rightInletTempMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStorageRightInletTempMin
moClass: storage:HddMotherBoardTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/rack-unit-[id]/enc-[id]/hdd-mobo-temp-stats
tcaStorageRightInletTempMax
Fault Code: F45377
Message
Threshold Crossed: storage:HddMotherBoardTempStats property: rightInletTempMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStorageRightInletTempMax
moClass: storage:HddMotherBoardTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/rack-unit-[id]/enc-[id]/hdd-mobo-temp-stats
tcaStorageRightInletTempAvg
Fault Code: F45378
Message
Threshold Crossed: storage:HddMotherBoardTempStats property: rightInletTempAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStorageRightInletTempAvg
moClass: storage:HddMotherBoardTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/rack-unit-[id]/enc-[id]/hdd-mobo-temp-stats
tcaStorageLeftInletTemp
Fault Code: F45382
Message
Threshold Crossed: storage:HddMotherBoardTempStats property: leftInletTemp
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStorageLeftInletTemp
moClass: storage:HddMotherBoardTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/rack-unit-[id]/enc-[id]/hdd-mobo-temp-stats
tcaStorageLeftInletTempMin
Fault Code: F45384
Message
Threshold Crossed: storage:HddMotherBoardTempStats property: leftInletTempMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStorageLeftInletTempMin
moClass: storage:HddMotherBoardTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/rack-unit-[id]/enc-[id]/hdd-mobo-temp-stats
tcaStorageLeftInletTempMax
Fault Code: F45385
Message
Threshold Crossed: storage:HddMotherBoardTempStats property: leftInletTempMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStorageLeftInletTempMax
moClass: storage:HddMotherBoardTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/rack-unit-[id]/enc-[id]/hdd-mobo-temp-stats
tcaStorageLeftInletTempAvg
Fault Code: F45386
Message
Threshold Crossed: storage:HddMotherBoardTempStats property: leftInletTempAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStorageLeftInletTempAvg
moClass: storage:HddMotherBoardTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/rack-unit-[id]/enc-[id]/hdd-mobo-temp-stats
tcaStorageRightOutletTemp
Fault Code: F45390
Message
Threshold Crossed: storage:HddMotherBoardTempStats property: rightOutletTemp
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStorageRightOutletTemp
moClass: storage:HddMotherBoardTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/rack-unit-[id]/enc-[id]/hdd-mobo-temp-stats
tcaStorageRightOutletTempMin
Fault Code: F45392
Message
Threshold Crossed: storage:HddMotherBoardTempStats property: rightOutletTempMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStorageRightOutletTempMin
moClass: storage:HddMotherBoardTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/rack-unit-[id]/enc-[id]/hdd-mobo-temp-stats
tcaStorageRightOutletTempMax
Fault Code: F45393
Message
Threshold Crossed: storage:HddMotherBoardTempStats property: rightOutletTempMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStorageRightOutletTempMax
moClass: storage:HddMotherBoardTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/rack-unit-[id]/enc-[id]/hdd-mobo-temp-stats
tcaStorageRightOutletTempAvg
Fault Code: F45394
Message
Threshold Crossed: storage:HddMotherBoardTempStats property: rightOutletTempAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStorageRightOutletTempAvg
moClass: storage:HddMotherBoardTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/rack-unit-[id]/enc-[id]/hdd-mobo-temp-stats
tcaStorageLeftOutletTemp
Fault Code: F45398
Message
Threshold Crossed: storage:HddMotherBoardTempStats property: leftOutletTemp
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStorageLeftOutletTemp
moClass: storage:HddMotherBoardTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/rack-unit-[id]/enc-[id]/hdd-mobo-temp-stats
tcaStorageLeftOutletTempMin
Fault Code: F45400
Message
Threshold Crossed: storage:HddMotherBoardTempStats property: leftOutletTempMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStorageLeftOutletTempMin
moClass: storage:HddMotherBoardTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/rack-unit-[id]/enc-[id]/hdd-mobo-temp-stats
tcaStorageLeftOutletTempMax
Fault Code: F45401
Message
Threshold Crossed: storage:HddMotherBoardTempStats property: leftOutletTempMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStorageLeftOutletTempMax
moClass: storage:HddMotherBoardTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/rack-unit-[id]/enc-[id]/hdd-mobo-temp-stats
tcaStorageLeftOutletTempAvg
Fault Code: F45402
Message
Threshold Crossed: storage:HddMotherBoardTempStats property: leftOutletTempAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStorageLeftOutletTempAvg
moClass: storage:HddMotherBoardTempStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/hdd-mobo-temp-stats
Affected MO: sys/rack-unit-[id]/enc-[id]/hdd-mobo-temp-stats
tcaEquipmentRearTemp
Fault Code: F45506
Message
Threshold Crossed: equipment:SiocTempStats property: rearTemp
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentRearTemp
moClass: equipment:SiocTempStats
Affected MO: sys/chassis-[id]/slot-[id]/temp-stats
tcaEquipmentRearTempMin
Fault Code: F45508
Message
Threshold Crossed: equipment:SiocTempStats property: rearTempMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentRearTempMin
moClass: equipment:SiocTempStats
Affected MO: sys/chassis-[id]/slot-[id]/temp-stats
tcaEquipmentRearTempMax
Fault Code: F45509
Message
Threshold Crossed: equipment:SiocTempStats property: rearTempMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentRearTempMax
moClass: equipment:SiocTempStats
Affected MO: sys/chassis-[id]/slot-[id]/temp-stats
tcaEquipmentRearTempAvg
Fault Code: F45510
Message
Threshold Crossed: equipment:SiocTempStats property: rearTempAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentRearTempAvg
moClass: equipment:SiocTempStats
Affected MO: sys/chassis-[id]/slot-[id]/temp-stats
tcaEquipmentFrontTemp
Fault Code: F45514
Message
Threshold Crossed: equipment:SiocTempStats property: frontTemp
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentFrontTemp
moClass: equipment:SiocTempStats
Affected MO: sys/chassis-[id]/slot-[id]/temp-stats
tcaEquipmentFrontTempMin
Fault Code: F45516
Message
Threshold Crossed: equipment:SiocTempStats property: frontTempMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentFrontTempMin
moClass: equipment:SiocTempStats
Affected MO: sys/chassis-[id]/slot-[id]/temp-stats
tcaEquipmentFrontTempMax
Fault Code: F45517
Message
Threshold Crossed: equipment:SiocTempStats property: frontTempMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentFrontTempMax
moClass: equipment:SiocTempStats
Affected MO: sys/chassis-[id]/slot-[id]/temp-stats
tcaEquipmentFrontTempAvg
Fault Code: F45518
Message
Threshold Crossed: equipment:SiocTempStats property: frontTempAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentFrontTempAvg
moClass: equipment:SiocTempStats
Affected MO: sys/chassis-[id]/slot-[id]/temp-stats
tcaEquipmentMidTemp
Fault Code: F45522
Message
Threshold Crossed: equipment:SiocTempStats property: midTemp
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentMidTemp
moClass: equipment:SiocTempStats
Affected MO: sys/chassis-[id]/slot-[id]/temp-stats
tcaEquipmentMidTempMin
Fault Code: F45524
Message
Threshold Crossed: equipment:SiocTempStats property: midTempMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentMidTempMin
moClass: equipment:SiocTempStats
Affected MO: sys/chassis-[id]/slot-[id]/temp-stats
tcaEquipmentMidTempMax
Fault Code: F45525
Message
Threshold Crossed: equipment:SiocTempStats property: midTempMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentMidTempMax
moClass: equipment:SiocTempStats
Affected MO: sys/chassis-[id]/slot-[id]/temp-stats
tcaEquipmentMidTempAvg
Fault Code: F45526
Message
Threshold Crossed: equipment:SiocTempStats property: midTempAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentMidTempAvg
moClass: equipment:SiocTempStats
Affected MO: sys/chassis-[id]/slot-[id]/temp-stats
tcaEquipmentCmcTemp
Fault Code: F45530
Message
Threshold Crossed: equipment:SiocTempStats property: cmcTemp
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentCmcTemp
moClass: equipment:SiocTempStats
Affected MO: sys/chassis-[id]/slot-[id]/temp-stats
tcaEquipmentCmcTempMin
Fault Code: F45532
Message
Threshold Crossed: equipment:SiocTempStats property: cmcTempMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentCmcTempMin
moClass: equipment:SiocTempStats
Affected MO: sys/chassis-[id]/slot-[id]/temp-stats
tcaEquipmentCmcTempMax
Fault Code: F45533
Message
Threshold Crossed: equipment:SiocTempStats property: cmcTempMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentCmcTempMax
moClass: equipment:SiocTempStats
Affected MO: sys/chassis-[id]/slot-[id]/temp-stats
tcaEquipmentCmcTempAvg
Fault Code: F45534
Message
Threshold Crossed: equipment:SiocTempStats property: cmcTempAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentCmcTempAvg
moClass: equipment:SiocTempStats
Affected MO: sys/chassis-[id]/slot-[id]/temp-stats
tcaEquipmentVicTemp
Fault Code: F45538
Message
Threshold Crossed: equipment:SiocTempStats property: vicTemp
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentVicTemp
moClass: equipment:SiocTempStats
Affected MO: sys/chassis-[id]/slot-[id]/temp-stats
tcaEquipmentVicTempMin
Fault Code: F45540
Message
Threshold Crossed: equipment:SiocTempStats property: vicTempMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentVicTempMin
moClass: equipment:SiocTempStats
Affected MO: sys/chassis-[id]/slot-[id]/temp-stats
tcaEquipmentVicTempMax
Fault Code: F45541
Message
Threshold Crossed: equipment:SiocTempStats property: vicTempMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentVicTempMax
moClass: equipment:SiocTempStats
Affected MO: sys/chassis-[id]/slot-[id]/temp-stats
tcaEquipmentVicTempAvg
Fault Code: F45542
Message
Threshold Crossed: equipment:SiocTempStats property: vicTempAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaEquipmentVicTempAvg
moClass: equipment:SiocTempStats
Affected MO: sys/chassis-[id]/slot-[id]/temp-stats
tcaStorageTemperature
Fault Code: F45647
Message
Threshold Crossed: storage:NvmeStats property: temperature
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStorageTemperature
moClass: storage:NvmeStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/nvme-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/nvme-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/nvme-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/nvme-stats
tcaStorageTemperatureMin
Fault Code: F45649
Message
Threshold Crossed: storage:NvmeStats property: temperatureMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStorageTemperatureMin
moClass: storage:NvmeStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/nvme-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/nvme-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/nvme-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/nvme-stats
tcaStorageTemperatureMax
Fault Code: F45650
Message
Threshold Crossed: storage:NvmeStats property: temperatureMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStorageTemperatureMax
moClass: storage:NvmeStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/nvme-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/nvme-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/nvme-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/nvme-stats
tcaStorageTemperatureAvg
Fault Code: F45651
Message
Threshold Crossed: storage:NvmeStats property: temperatureAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStorageTemperatureAvg
moClass: storage:NvmeStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/nvme-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/nvme-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/nvme-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/nvme-stats
tcaStorageDriveLifeUsedPercentage
Fault Code: F45655
Message
Threshold Crossed: storage:NvmeStats property: driveLifeUsedPercentage
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStorageDriveLifeUsedPercentage
moClass: storage:NvmeStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/nvme-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/nvme-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/nvme-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/nvme-stats
tcaStorageDriveLifeUsedPercentageMin
Fault Code: F45657
Message
Threshold Crossed: storage:NvmeStats property: driveLifeUsedPercentageMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStorageDriveLifeUsedPercentageMin
moClass: storage:NvmeStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/nvme-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/nvme-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/nvme-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/nvme-stats
tcaStorageDriveLifeUsedPercentageMax
Fault Code: F45658
Message
Threshold Crossed: storage:NvmeStats property: driveLifeUsedPercentageMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStorageDriveLifeUsedPercentageMax
moClass: storage:NvmeStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/nvme-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/nvme-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/nvme-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/nvme-stats
tcaStorageDriveLifeUsedPercentageAvg
Fault Code: F45659
Message
Threshold Crossed: storage:NvmeStats property: driveLifeUsedPercentageAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStorageDriveLifeUsedPercentageAvg
moClass: storage:NvmeStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/nvme-stats
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/nvme-stats
Affected MO: sys/chassis-[id]/storage-[type]-[id]/nvme-stats
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/nvme-stats
tcaStoragePowerOnHours
Fault Code: F46020
Message
Threshold Crossed: storage:SsdHealthStats property: powerOnHours
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStoragePowerOnHours
moClass: storage:SsdHealthStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
tcaStoragePowerOnHoursMin
Fault Code: F46022
Message
Threshold Crossed: storage:SsdHealthStats property: powerOnHoursMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStoragePowerOnHoursMin
moClass: storage:SsdHealthStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
tcaStoragePowerOnHoursMax
Fault Code: F46023
Message
Threshold Crossed: storage:SsdHealthStats property: powerOnHoursMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStoragePowerOnHoursMax
moClass: storage:SsdHealthStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
tcaStoragePowerOnHoursAvg
Fault Code: F46024
Message
Threshold Crossed: storage:SsdHealthStats property: powerOnHoursAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStoragePowerOnHoursAvg
moClass: storage:SsdHealthStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
tcaStorageWearStatusInDays
Fault Code: F46028
Message
Threshold Crossed: storage:SsdHealthStats property: wearStatusInDays
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStorageWearStatusInDays
moClass: storage:SsdHealthStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
tcaStorageWearStatusInDaysMin
Fault Code: F46030
Message
Threshold Crossed: storage:SsdHealthStats property: wearStatusInDaysMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStorageWearStatusInDaysMin
moClass: storage:SsdHealthStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
tcaStorageWearStatusInDaysMax
Fault Code: F46031
Message
Threshold Crossed: storage:SsdHealthStats property: wearStatusInDaysMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStorageWearStatusInDaysMax
moClass: storage:SsdHealthStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
tcaStorageWearStatusInDaysAvg
Fault Code: F46032
Message
Threshold Crossed: storage:SsdHealthStats property: wearStatusInDaysAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStorageWearStatusInDaysAvg
moClass: storage:SsdHealthStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
tcaStoragePowerCycleCount
Fault Code: F46036
Message
Threshold Crossed: storage:SsdHealthStats property: powerCycleCount
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStoragePowerCycleCount
moClass: storage:SsdHealthStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
tcaStoragePowerCycleCountMin
Fault Code: F46038
Message
Threshold Crossed: storage:SsdHealthStats property: powerCycleCountMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStoragePowerCycleCountMin
moClass: storage:SsdHealthStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
tcaStoragePowerCycleCountMax
Fault Code: F46039
Message
Threshold Crossed: storage:SsdHealthStats property: powerCycleCountMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStoragePowerCycleCountMax
moClass: storage:SsdHealthStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
tcaStoragePowerCycleCountAvg
Fault Code: F46040
Message
Threshold Crossed: storage:SsdHealthStats property: powerCycleCountAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStoragePowerCycleCountAvg
moClass: storage:SsdHealthStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
tcaStoragePercentageLifeLeft
Fault Code: F46044
Message
Threshold Crossed: storage:SsdHealthStats property: percentageLifeLeft
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStoragePercentageLifeLeft
moClass: storage:SsdHealthStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
tcaStoragePercentageLifeLeftMin
Fault Code: F46046
Message
Threshold Crossed: storage:SsdHealthStats property: percentageLifeLeftMin
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStoragePercentageLifeLeftMin
moClass: storage:SsdHealthStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
tcaStoragePercentageLifeLeftMax
Fault Code: F46047
Message
Threshold Crossed: storage:SsdHealthStats property: percentageLifeLeftMax
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStoragePercentageLifeLeftMax
moClass: storage:SsdHealthStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
tcaStoragePercentageLifeLeftAvg
Fault Code: F46048
Message
Threshold Crossed: storage:SsdHealthStats property: percentageLifeLeftAvg
Explanation
Recommended Action
Fault Details
mibFaultName: tcaStoragePercentageLifeLeftAvg
moClass: storage:SsdHealthStats
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]
Affected MO: sys/rack-unit-[id]/enc-[id]/disk-[id]/ssd-health-stats-[id]