Overview

Cisco Unified Computing System Overview

Cisco UCS has a unique architecture that integrates compute, data network access, and storage network access into a common set of components under a single-pane-of-glass management interface.

Cisco UCS fuses access layer networking and servers. This high-performance, next-generation server system provides a data center with a high degree of workload agility and scalability. The hardware and software components support Cisco's unified fabric, which runs multiple types of data center traffic over a single converged network adapter.

Figure 1. Cisco Unified Computing System Architecture

Architectural Simplification

The simplified architecture of Cisco UCS reduces the number of required devices and centralizes switching resources. By eliminating switching inside a chassis, network access-layer fragmentation is significantly reduced. Cisco UCS implements Cisco unified fabric within racks and groups of racks, supporting Ethernet and Fibre Channel protocols over 10 Gigabit Cisco Data Center Ethernet and Fibre Channel over Ethernet (FCoE) links. This radical simplification reduces the number of switches, cables, adapters, and management points by up to two-thirds. All devices in a Cisco UCS domain remain under a single management domain, which remains highly available through the use of redundant components.

High Availability

The management and data plane of Cisco UCS is designed for high availability and redundant access layer fabric interconnects. In addition, Cisco UCS supports existing high availability and disaster recovery solutions for the data center, such as data replication and application-level clustering technologies.

Scalability

A single Cisco UCS domain supports multiple chassis and their servers, all of which are administered through one Cisco UCS Manager. For more detailed information about the scalability, speak to your Cisco representative.

Flexibility

A Cisco UCS domain allows you to quickly align computing resources in the data center with rapidly changing business requirements. This built-in flexibility is determined by whether you choose to fully implement the stateless computing feature. Pools of servers and other system resources can be applied as necessary to respond to workload fluctuations, support new applications, scale existing software and business services, and accommodate both scheduled and unscheduled downtime. Server identity can be abstracted into a mobile service profile that can be moved from server to server with minimal downtime and no need for additional network configuration.

With this level of flexibility, you can quickly and easily scale server capacity without having to change the server identity or reconfigure the server, LAN, or SAN. During a maintenance window, you can quickly do the following:

  • Deploy new servers to meet unexpected workload demand and rebalance resources and traffic.

  • Shut down an application, such as a database management system, on one server and then boot it up again on another server with increased I/O capacity and memory resources.

Optimized for Server Virtualization

Cisco UCS has been optimized to implement VM-FEX technology. This technology provides improved support for server virtualization, including better policy-based configuration and security, conformance with a company's operational model, and accommodation for VMware's VMotion.

IOMs and Fabric Interconnects Connectivity

Each chassis is equipped with two IOMs: IOM 1 should be connected to Fabric Interconnect A. IOM 2 should be connected to Fabric Interconnect B. This configuration provides redundant paths, ensuring uninterrupted operation of the Cisco UCS system even in the event of a failure in one of the Fabric Interconnects or IOMs. Additionally, this configuration enables traffic load distribution across both Fabric Interconnects, enhancing load balancing and increasing throughput. As a result, the Cisco UCS system achieves high availability, reliability, and optimal performance, making it ideal for data center environments.

Uplink Connectivity

Use fabric interconnect ports configured as uplink ports to connect to uplink upstream network switches. Connect these uplink ports to upstream switch ports as individual links, or as links configured as port channels. Port channel configurations provide bandwidth aggregation as well as link redundancy.

You can achieve northbound connectivity from the fabric interconnect through a standard uplink, a port channel, or a virtual port channel configuration. The port channel name and ID configured on fabric interconnect should match the name and ID configuration on the upstream Ethernet switch.

It is also possible to configure a port channel as a vPC, where port channel uplink ports from a fabric interconnect are connected to different upstream switches. After all uplink ports are configured, create a port channel for these ports.

Downlink Connectivity

Beginning with release 4.3(2a), Cisco UCS Manager supports Cisco UCS X9508 server chassis with Cisco UCS X-Series servers. Cisco UCS X-Series servers support Intelligent Fabric Modules (IFM), which function similarly to the Input/Output Module (IOM) in Cisco UCS B-Series servers. This guide uses the term IOM to refer both IOM and IFM.

Each fabric interconnect is connected to IOMs in the UCS chassis, which provides connectivity to each blade server. Internal connectivity from blade servers to IOMs is transparently provided by Cisco UCS Manager using 10BASE-KR Ethernet standard for backplane implementations, and no additional configuration is required. You must configure the connectivity between the fabric interconnect server ports and IOMs. Each IOM, when connected with the fabric interconnect server port, behaves as a line card to fabric interconnect, hence IOMs should never be cross-connected to the fabric interconnect. Each IOM is connected directly to a single fabric interconnect.

The Fabric Extender (also referred to as the IOM, or FEX) logically extends the fabric interconnects to the blade server. The best analogy is to think of it as a remote line card that’s embedded in the blade server chassis, allowing connectivity to the external world. IOM settings are pushed via Cisco UCS Manager and are not managed directly. The primary functions of this module are to facilitate blade server I/O connectivity (internal and external), multiplex all I/O traffic up to the fabric interconnects, and help monitor and manage the Cisco UCS infrastructure.

Configure Fabric interconnect ports that should be connected to downlink IOM cards as server ports. Make sure there is physical connectivity between the fabric interconnect and IOMs. You must also configure the IOM ports and the global chassis discovery policy.


Note


For UCS 2200 I/O modules, you can also select the Port Channel option and all I/O module-connected server ports will be automatically added to a port channel.


Unified Fabric

With unified fabric, multiple types of data center traffic can run over a single Data Center Ethernet (DCE) network. Instead of having a series of different host bus adapters (HBAs) and network interface cards (NICs) present in a server, unified fabric uses a single converged network adapter. This type of adapter can carry LAN and SAN traffic on the same cable.

Cisco UCS uses Fibre Channel over Ethernet (FCoE) to carry Fibre Channel and Ethernet traffic on the same physical Ethernet connection between the fabric interconnect and the server. This connection terminates at a converged network adapter on the server, and the unified fabric terminates on the uplink ports of the fabric interconnect. On the core network, the LAN and SAN traffic remains separated. Cisco UCS does not require that you implement unified fabric across the data center.

The converged network adapter presents an Ethernet interface and Fibre Channel interface to the operating system. At the server, the operating system is not aware of the FCoE encapsulation because it sees a standard Fibre Channel HBA.

At the fabric interconnect, the server-facing Ethernet port receives the Ethernet and Fibre Channel traffic. The fabric interconnect (using Ethertype to differentiate the frames) separates the two traffic types. Ethernet frames and Fibre Channel frames are switched to their respective uplink interfaces.

Fibre Channel over Ethernet

Cisco UCS leverages Fibre Channel over Ethernet (FCoE) standard protocol to deliver Fibre Channel. The upper Fibre Channel layers are unchanged, so the Fibre Channel operational model is maintained. FCoE network management and configuration is similar to a native Fibre Channel network.

FCoE encapsulates Fibre Channel traffic over a physical Ethernet link. FCoE is encapsulated over Ethernet with the use of a dedicated Ethertype, 0x8906, so that FCoE traffic and standard Ethernet traffic can be carried on the same link. FCoE has been standardized by the ANSI T11 Standards Committee.

Fibre Channel traffic requires a lossless transport layer. Instead of the buffer-to-buffer credit system used by native Fibre Channel, FCoE depends upon the Ethernet link to implement lossless service.

Ethernet links on the fabric interconnect provide two mechanisms to ensure lossless transport for FCoE traffic:

  • Link-level flow control

  • Priority flow control

Link-Level Flow Control

IEEE 802.3x link-level flow control allows a congested receiver to signal the endpoint to pause data transmission for a short time. This link-level flow control pauses all traffic on the link.

The transmit and receive directions are separately configurable. By default, link-level flow control is disabled for both directions.

On each Ethernet interface, the fabric interconnect can enable either priority flow control or link-level flow control (but not both).

When an interface on a Cisco UCS Fabric Interconnects 9108 100G, Cisco UCS 6500 Series Fabric Interconnect, or Cisco UCS 6400 Series Fabric Interconnect has Priority Flow Control (PFC) admin configured as auto and Link-Level Flow Control (LLFC) admin configured as on, the PFC operation mode will be off and the LLFC operation mode will be on. On UCS 6300 Series and earlier Fabric Interconnects, the same configuration will result in the PFC operation mode being on and the LLFC operation mode being off.

Priority Flow Control

The priority flow control (PFC) feature applies pause functionality to specific classes of traffic on the Ethernet link. For example, PFC can provide lossless service for the FCoE traffic, and best-effort service for the standard Ethernet traffic. PFC can provide different levels of service to specific classes of Ethernet traffic (using IEEE 802.1p traffic classes).

PFC decides whether to apply pause based on the IEEE 802.1p CoS value. When the fabric interconnect enables PFC, it configures the connected adapter to apply the pause functionality to packets with specific CoS values.

By default, the fabric interconnect negotiates to enable the PFC capability. If the negotiation succeeds, PFC is enabled and link-level flow control remains disabled (regardless of its configuration settings). If the PFC negotiation fails, you can either force PFC to be enabled on the interface or you can enable IEEE 802.x link-level flow control.

Cisco UCS Building Blocks and Connectivity

Figure 2. Cisco UCS Building Blocks and Connectivity


As shown in the figure above, the primary components included within Cisco UCS are as follows:

  • Cisco UCS Manager—Cisco UCS Manager is the centralized management interface for Cisco UCS. For more information on Cisco UCS Manager, see Introduction to Cisco UCS Manager in Cisco UCS Manager Getting Started Guide

  • Cisco UCS Fabric Interconnects—The Cisco UCS Fabric Interconnect is the core component of Cisco UCS deployments, providing both network connectivity and management capabilities for the Cisco UCS system. The Cisco UCS Fabric Interconnects run the Cisco UCS Manager control software and consist of the following components:

    • Cisco UCS fabric interconnects:

      • Cisco UCS Fabric Interconnects 9108 100G (Cisco UCS X-Series Direct)

      • Cisco UCS 6536 Fabric Interconnect

      • Cisco UCS 6400 Series Fabric Interconnect

      • Cisco UCS 6332 Series Fabric Interconnects

      • Cisco UCS-FI-6324 (Cisco UCS Mini)

    • Transceivers for network and storage connectivity

    • Expansion modules for various Fabric Interconnects

    • Cisco UCS Manager software

    For more information on Cisco UCS Fabric Interconnects, see Cisco UCS Fabric Infrastructure Portfolio.

  • Cisco UCS I/O Modules and Cisco UCS Fabric Extender—IO modules are also known as Cisco FEX or simply FEX modules. These modules serve as line cards to the FIs in the same way that Cisco Nexus Series switches can have remote line cards. IO modules also provide interface connections to blade servers. They multiplex data from blade servers and provide this data to FIs and do the same in the reverse direction. In production environments, IO modules are always used in pairs to provide redundancy and failover.


    Important


    The 40G backplane setting is not applicable for 22xx IOMs.


  • Cisco UCS Blade Server Chassis—The Cisco UCS 5100 Series Blade Server Chassis is a crucial building block of Cisco UCS, delivering a scalable and flexible architecture for current and future data center needs, while helping reduce total cost of ownership.

  • Cisco UCS Blade and Rack Servers—Cisco UCS Blade servers are at the heart of the UCS solution. They come in various system resource configurations in terms of CPU, memory, and hard disk capacity. The Cisco UCS rack-mount servers are standalone servers that can be installed and controlled individually. Cisco provides Fabric Extenders (FEXs) for the rack-mount servers. FEXs can be used to connect and manage rack-mount servers from FIs. Rack-mount servers can also be directly attached to the fabric interconnect.

    Small and Medium Businesses (SMBs) can choose from different blade configurations as per business needs.

  • Cisco UCS I/O Adapters—Cisco UCS B-Series Blade Servers are designed to support up to two network adapters. This design can reduce the number of adapters, cables, and access-layer switches by as much as half because it eliminates the need for multiple parallel infrastructure for both LAN and SAN at the server, chassis, and rack levels.

Cisco UCS Fabric Infrastructure Portfolio

The Cisco UCS fabric interconnects are top-of-rack devices and provide unified access to the Cisco UCS domain. The following fabric interconnects are available in the Cisco UCS fabric interconnects product family:

  • Cisco UCS Manager Release 4.3(4b) introduces Cisco UCS Fabric Interconnects 9108 100G (Cisco UCS X-Series Direct).

  • Cisco UCS Manager Release 4.2(3b) introduces Cisco UCS 6536 Fabric Interconnect to the Cisco UCS 6500 Series Fabric Interconnects.

  • Cisco UCS Manager Release 4.1 introduces the Cisco UCS 64108 Fabric Interconnect to the Cisco UCS 6400 Series Fabric Interconnects.

  • Cisco UCS 6300 Series Fabric Interconnects

  • Cisco UCS 6324 Fabric Interconnects


Note


The Cisco UCS 6200 Series, Cisco UCS 6100 Series Fabric Interconnects, and Cisco UCS 2104 I/O Modules have reached end of life.


Cisco UCS Manager Fabric Interconnects

Ports on the Cisco UCS Fabric Interconnects

Cisco UCS Fabric Interconnects 9108 100G (Cisco UCS X-Series Direct) has eight ports that include:

  • Ports 1 & 2 that are unified ports to manage all SAN features and configurations.

  • The 100G Ethernet ports [1-8] can also be configured as 25Gx4 SFP28 compatible breakout ports or 4x10G ports, offering flexible networking solutions to accommodate a range of data center needs.

  • The 32G Fibre Channel ports [1 & 2] can also be configured as 8Gx4 SFP28 compatible breakout ports offering flexible networking solutions to accommodate a range of data center needs.


Note


Migration of any previous generation Fabric Interconnects to the Cisco UCS 9108 100G Intelligent Fabric Module is currently not supported.


Ports on the Cisco UCS 6536 Fabric Interconnects can be configured to carry either Ethernet or Fibre Channel traffic. You can configure only ports 33-36 to carry Fibre Channel traffic. The ports cannot be used by a Cisco UCS domain until you configure them.

Ports on the Cisco UCS 6400 Series Fabric Interconnects can be configured to carry either Ethernet or Fibre Channel traffic. You can configure only ports 1-16 to carry Fibre Channel traffic. The ports cannot be used by a Cisco UCS domain until you configure them.


Note


  • The Cisco UCS 6454 Fabric Interconnect supported 8 unified ports (ports 1 - 8) with Cisco UCS Manager 4.0(1) and 4.0(2), but with Release 4.0(4) and later releases, it supports 16 unified ports (ports 1 - 16).

    When you configure a port on a Fabric Interconnect, the administrative state is automatically set to enabled. If the port is connected to another device, this may cause traffic disruption. The port can be disabled and enabled after it has been configured.


The following table summarizes the port support for third, fourth, fifth generation of Cisco UCS Fabric Interconnects, and Cisco UCS Fabric Interconnects 9108 100G.

Third Generation

Fourth Generation

Fifth Generation

Cisco UCS X-Series Direct

Item

Cisco UCS 6332

Cisco UCS 6332-16UP

Cisco UCS 6454

Cisco UCS 64108

Cisco UCS 6536

Cisco UCS 9108 100G FI

Description

32-Port Fabric Interconnect

40-Port Fabric Interconnect

54-Port Fabric Interconnect

108-Port Fabric Interconnect

36-Port Fabric Interconnect

8 Ports

Form factor

1 RU

1 RU

1 RU

2 RU

1 RU

1 RU

Number of fixed 10 GB Interfaces

96 (40G to 4 x 10G breakout cables), QSA, Port 13 and 14 do not support 40G to 10G breakout

88 (40G to 4 x 10G breakout cables)

48 10G/25G interfaces

96 10G/25G interfaces

36 10G/25G/40G/100G interfaces

Note

 

144 breakout ports (36x4)

Number of Unified Ports

16

16

This FI supported 8 unified ports (ports 1 - 8) with Cisco UCS Manager 4.0(1) and 4.0(2), but with Release 4.0(4) and later it supports 16 unified ports (ports 1 - 16).

16

ports 1-16

4

Note

 

16 breakout ports (4x4)

Ports 1-2

Unified Port Speeds in Gbps

1G/10G or 4G/8G/16G-FC

10G/25G or 8G/16G/32G-FC

10G/25G or 8G/16G/32G-FC

10G/25G/40G/100G FC

8G/16G/32G FC

Number of 40-Gbps ports

32

24

6 40G/100G

12 40G/100G

36

Unified Port Range

None

Ports 1-16

Ports 1-16

Ports 1-16

Ports 33-36

Ports 1-2

Compatibility with the IOM

UCS 2204, UCS 2208, UCS 2304, UCS 2304V2

UCS 2204, UCS 2208, UCS 2304, UCS 2304V2

UCS 2204, UCS 2208, UCS 2408

UCS 2204, UCS 2208, UCS 2408

UCS 2408, UCS 2304, UCS 2304V2

Compatibility with the FEX

Cisco Nexus 2232PP

Cisco Nexus 2232TM-E

Cisco Nexus 2348UPQ

Cisco Nexus 2232PP

Cisco Nexus 2232TM-E

Cisco Nexus 2348UPQ

Cisco Nexus 2232PP

Cisco Nexus 2232TM-E

Cisco Nexus 93180YC-FX3

Cisco Nexus 2232PP

Cisco Nexus 2232TM-E

Cisco Nexus 93180YC-FX3

Cisco Nexus 93180YC-FX3

N2K-C2348UPQ

Expansion Slots

None

None

None

None

None

Fan Modules

4

4

4

3

6

3

Power Supplies

2 (AC/DC)

2 (AC/DC)

2 (AC/DC)

2 (AC/DC)

2 (AC)

Supplied by chassis

Cisco UCS X-Series Direct

Overview of Cisco UCS Fabric Interconnects 9108 100G (Cisco UCS X-Series Direct)

The Cisco UCS X-Series Direct is identified by the product ID: UCSX-S9108-100G, and the product description: Cisco UCS Fabric Interconnects 9108 100G.

The Cisco UCS Fabric Interconnects 9108 100G platform streamlines data center architecture by eliminating the need for separate Fabric Interconnects (FIs), integrating essential networking and management functionality directly within the chassis. The Cisco UCS Fabric Interconnects 9108 100G platform is designed for deployments in smaller settings, where the compute server requirements are less extensive than those of a traditional data center. This solution is centered around a single-chassis system, the Cisco UCS X9508 Chassis, which incorporates Cisco UCS Fabric Interconnects 9108 100G directly into the chassis for a consolidated and efficient infrastructure. To ensure high availability, each chassis houses two Cisco UCS Fabric Interconnects 9108 100G that establish direct downlink connections to servers and provide uplink connections to facilitate seamless integration with both Local Area Network (LAN) and Storage Area Network (SAN) systems. The Fabric Interconnects (FIs) are adeptly designed to fit into the Cisco UCS X-Series chassis, presenting as a single module within the NX-OS environment that merges QSFP ports with server backplane ports.

The hardware configuration of the Cisco UCS Fabric Interconnects 9108 100G platform retains the same form factor as the standard Cisco UCS X-Series chassis, and features 17 MACs, each configurable for 10G, 25G, 40G, or 100G connectivity. It is equipped with an CPU, for operating NX-OS, Cisco UCS Manager for management and Chassis Management Controller (CMC) software. The Cisco UCS Fabric Interconnects 9108 100G includes an onboard Ethernet switch with multiple 10G links dedicated to out-of-band communication between blade components such as the Baseboard Management Controller (BMC), CMC. A dedicated 1G link facilitates IFM-to-IFM clustering and high availability synchronization. Within the Cisco UCS Fabric Interconnects 9108 100G, Ethernet ports 1-8, backplane ports 9-16, and the Baseboard Interface (BIF) port 17 coexist on a singular switch card. Ports 1-2 are unified to manage all SAN features and configurations. The 100G Ethernet ports [1-8] can also be configured as 25Gx4 SFP28 compatible breakout ports or 4x10G ports, offering flexible networking solutions to accommodate a range of data center needs.

Cisco UCS Fabric Interconnects 9108 100G (Cisco UCS X-Series Direct) Architecture

The Cisco UCS X-Series Direct architecture is engineered to support a diverse range of workloads, from traditional applications to cloud-native services, by offering a composable and disaggregated approach to computing resources. Key components of the Cisco UCS X-Series Direct architecture include:

  • Cisco UCSX-9508 Chassis—A modular and future-proof chassis that can accommodate various types of compute nodes, providing the flexibility to adapt to different workload requirements without the need for a complete hardware overhaul.

  • Cisco UCS Fabric Interconnects 9108 100G—This solution is centered around a single-chassis system, the Cisco UCS X9508 Chassis, which incorporates Cisco UCS Fabric Interconnects 9108 100G directly into the chassis for a consolidated and efficient infrastructure. To ensure high availability, each chassis houses two Cisco UCS Fabric Interconnects 9108 100G that establish direct downlink connections to servers and provide uplink connections to facilitate seamless integration with both Local Area Network (LAN) and Storage Area Network (SAN) systems.

  • Software Architecture—In terms of the startup and operational model, the management, Cisco UCS Manager aligns with the approach taken in the Cisco UCS 6500 and 6400 Series Fabric Interconnects. In this model, Cisco UCS Manager is encapsulated within a container and is initiated by the underlying NX-OS, depending on the selected management mode.

Port Breakout Functionality on Cisco UCS Fabric Interconnects 9108 100G (Cisco UCS X-Series Direct)

The Cisco UCS Fabric Interconnects 9108 100G is equipped with advanced port breakout functionality, which allows network administrators to subdivide a single high-bandwidth port into multiple lower-bandwidth ports. This feature is particularly beneficial for optimizing port utilization, managing cabling complexity, and adapting to various bandwidth requirements.

Physical Port

Breakout Options

Logical Ports After Breakout

Supported Speeds through breakout cables

Ethernet 1/1 - Ethernet 1/8

4x25G

Ethernet 1/1/1 to Ethernet 1/8/4

Up to 8x100 Gbps

Fibre Channel 1/1 and 1/2

4x8G, 4x16G, 4x32G

Fibre Channel 1/1/1 to Fibre Channel 1/2/4

Up to 8x32Gbps

Breakout Port Guidelines

Breakout ports are supported as destinations for traffic monitoring. The following are the guidelines for breakout functionality for Cisco UCS Fabric Interconnects 9108 100G:

  • Breakout Availability: Breakout functionality is available for physical ports 1-8.

  • Ethernet Breakout: Ethernet breakout ports can be configured on physical ports 1 through 8, resulting in 32 logical ports.

  • Fibre Channel Breakout: Fibre Channel breakout ports can be configured on unified ports 1/8 and 2/8, resulting in 8 logical ports.

  • Port Configurations: Physical Ports 1-8 can be configured as Uplink Ports, FCoE Uplink Ports, FCoE Storage Ports, and Appliance Ports.

  • Port Conversions: All port conversions support up to 8 standard ports or 8 breakout ports.

  • Server Ports: Configuration as Server Ports is not supported.

  • Fibre Channel Direct Ports: Direct ports for Fibre Channel are not supported.

  • Traffic Monitoring: Breakout ports can be utilized as destinations for traffic monitoring.

Cisco UCS 6500 Series Fabric Interconnects

Cisco UCS 6536 Fabric Interconnect Overview

The Cisco UCS 6536 Fabric Interconnect is a core part of the Cisco Unified Computing System, providing both network connectivity and management capabilities for the system. The Cisco UCS 6536 Fabric Interconnect provides the communication backbone and management connectivity for UCS B-series blade servers and UCS C-series rack servers.

Cisco UCS 6500 Series Fabric Interconnects currently include Cisco UCS 6536 Fabric Interconnect. All servers attached to a Cisco UCS 6536 Fabric Interconnect become part of a single, highly available management domain. In addition, by supporting a unified fabric, Cisco UCS 6536 Fabric Interconnect provides both LAN and SAN connectivity for all servers within its domain.

The Cisco UCS 6536 Fabric Interconnect supports multiple traffic classes over a lossless Ethernet fabric from the server through the fabric interconnect.

Port Breakout Functionality on Cisco UCS 6536 Fabric Interconnects

The Cisco UCS 6536 36-Port Fabric Interconnect is a One-Rack-Unit (1RU) 1/10/25/40/100 Gigabit Ethernet, FCoE, and Fibre Channel switch offering up to 7.42 Tbps throughput and up to 36 ports.

Cisco UCS 6536 Fabric Interconnect supports splitting a single 40 Gigabit(G)/100G Quad Small Form-factor Pluggable (QSFP) port into four 10G/25G ports using a supported breakout cable. The switch has 32 40/100-Gbps Ethernet ports and four unified ports that can support 40/100-Gbps Ethernet ports or 16 Fiber Channel (FC) ports after breakout at 8/16/32-Gbps FC speeds. The 16 FC ports after breakout can operate as an FC Uplink or FC storage port. The switch also supports two ports (Port 9 and Port 10) at 1-Gbps speed using QSA, and all 36 ports can breakout for 10 or 25 Gbps Ethernet connectivity. All Ethernet ports can support FCoE.

Port breakout is supported for Ethernet ports (1-32) and Unified ports (33-36). These 40/100G ports are numbered in a 2-tuple naming convention. The process of changing the configuration from 40G to 10G, or from 100G to 25G is called breakout, and the process of changing the configuration from [4X]10G to 40G or from [4X]25G to 100G is called unconfigure.

When you break out a 40G port into 10G ports or a 100G port into 25G ports, the resulting ports are numbered using a 3-tuple naming convention. For example, the breakout ports of the second 40-Gigabit Ethernet port are numbered as 1/31/1, 1/31/2, 1/31/3, and 1/31/4.

FC breakout is supported on ports 36 through 33 when each port is configured with a four-port breakout cable. For example: Four FC breakout ports on the physical port 33 are numbered as 1/33/1, 1/33/2, 1/33/3, and 1/33/4.


Note


Fibre Channel support is only available through the configuration of the Unified Ports (36-33) as Fibre Channel breakout port.


The following image shows the rear view of the Cisco UCS 6536 fabric interconnect:

Figure 3. Cisco UCS 6536 Fabric Interconnect Rear View

The following image shows the rear view of the Cisco UCS 6536 fabric interconnect that include Ports and LEDs:

Figure 4. Cisco UCS 6536 Fabric Interconnect Rear View

1

Ports 1-32.

Uplink ports are Ethernet port that can operate with the port speed of 10 Gbps/25 Gbps/40 Gbps/100 Gbps.

When using a breakout cable, each of these ports can operate as: 4 x 10 Gbps/4x 25 Gbps/1 x 40 Gbps/1 x 100 Gbps Ethernet or FCoE ports.

2

Ports 33-36.

Unified Ports can operate with port speed of 10 Gbps/25 Gbps/ 40 Gbps/100 Gbps Ethernet.

or

8 Gbps/16 Gbps/32 Gbps Fibre Channel (FC).

When using a breakout cable, each of these ports can operate as 4 x 10 Gbps/4 x 25 Gbps Ethernet or 4x8Gbps/4x16Gbps/4x32Gbps FC ports.

3

Ports 1-36.

Uplink ports and Unified ports that can be configured as Ethernet Breakout Port and can operate with the port speed of 10 Gbps/25 Gbps/40 Gbps/100 Gbps.

When using a breakout cable, each of these ports can operate as: 4 x 10 Gbps/4x 25 Gbps/1 x 40 Gbps/1 x 100 Gbps Ethernet or FCoE ports.

4

System environment (fan fault) LED

5

System status (STS) LED

6

Beacon (BCN) LED

Breakout Port Guidelines

The following are the guidelines for breakout functionality for Cisco UCS 6536 Fabric Interconnects:

  • The configurable breakout ports are from port 1-36.

  • You can configure the speed for each breakout port. Each breakout port can be configured at the speed of 4 x 8 Gbps/ 4 x 16 Gbps/ 4 x 32 Gbps for Fibre Channel.

    • For Fibre Channel breakout, each breakout port can be configured at the speed of 4 x 8 Gbps/ 4 x 16 Gbps/ 4 x 32 Gbps.

    • For Ethernet breakout, each breakout port can be configured at the speed of 4 x 10 Gbps/4 x 25 Gbps.

  • Fibre Channel breakout ports are supported, and Fiber Channel direct ports are not supported.

  • FC breakout port can be configured from 1/36 through 1/33. FC breakout ports (36-33) cannot be configured unless the previous ports are FC breakout ports. Configuration of a single (individual) FC breakout port is also supported.

  • If the breakout mode for any of the supported Fabric Interconnect ports (1-36) is an Ethernet breakout, the Fabric Interconnect does not lead to a reboot.

  • If the breakout mode for any of the supported Fabric Interconnect ports (36-33) is a Fibre Channel uplink breakout, the Fabric Interconnect leads to a reboot.

  • Breakout ports are supported as destinations for traffic monitoring.

  • Ports 1-36 can be configured as Server Port, FCoE Uplink Port, Appliance Port, and Monitor Port.

  • Port 36-33 can be configured also as FC Uplink Port or FC Storage Port when configured as unified port.

Cisco UCS 6400 Series Fabric Interconnects

Cisco UCS 6400 Series Fabric Interconnect Overview

Cisco UCS 6400 Series Fabric Interconnect provides both network connectivity and management capabilities to the Cisco UCS system. The fabric interconnect provides Ethernet and Fibre Channel to the servers in the system, the servers connect to the fabric interconnect, and then to the LAN or SAN.

Each Cisco UCS 6400 Series Fabric Interconnect runs Cisco UCS Manager to fully manage all Cisco UCS elements. The fabric interconnect supports 10/25 Gigabit ports in the fabric with 40/100 Gigabit uplink ports. High availability can be achieved when a Cisco UCS 6400 Series Fabric Interconnect is connected to another Cisco UCS 6400 Series Fabric Interconnect through the L1 or L2 port on each device.

Cisco UCS 6400 Series Fabric Interconnect consists of:

  • Cisco UCS 6454 Fabric Interconnects

  • Cisco UCS 64108 Fabric Interconnects

Cisco UCS 64108 Fabric Interconnect

The Cisco UCS 64108 Fabric Interconnect is a 2 RU top-of-rack (TOR) switch that mounts in a standard 19-inch rack such as the Cisco R Series rack.

The high-density Cisco UCS 64108 Fabric Interconnect has 96 10/25 Gb SFP28 ports and 12 40/100 Gb QSFP28 ports. Each 40/100 Gb port can break out into 4 x 10/25 Gb uplink ports. Ports 1 - 16 are unified ports that support 10/25 GbE or 8/16/32G Fibre Channel speeds. Ports 89-96 support 1Gbps Ethernet speeds.

The Cisco UCS 64108 Fabric Interconnect supports either:

  • Eight FCoE port channels

  • Or Four SAN port channels

  • or Four SAN port channels and four FCoE port channels

The Cisco UCS 64108 Fabric Interconnect also has one network management port, one RS-232 serial console port for setting the initial configuration, and one USB port for saving or loading configurations. The FI also includes L1/L2 ports for connecting two fabric interconnects in a high-availability configuration.

The Cisco UCS 64108 Fabric Interconnect also contains a CPU board that consists of:

  • Intel Xeon Processor, 6 core

  • 64 GB of RAM

  • 8 MB of NVRAM (4 x NVRAM chips)

  • 128 GB SSD (bootflash)

Figure 5. Cisco UCS 64108 Fabric Interconnect Rear View

1

Ports 1-16

Unified ports:

  • 10/25 Gbps Ethernet or FCoE

  • 8/16/32 Gbps Fibre Channel

2

Ports 17-88

(10/25 Gbps Ethernet or FCoE)

3

Ports 89-96

  • 10/25 Gbps Ethernet or FCoE

  • 1 Gbps Ethernet

4

Uplink Ports 97-108 (40/100 Gbps Ethernet or FCoE)

Each of these ports can be 4 x 10/25 Gbps Ethernet or FCoE uplink ports when using a breakout cable.

5

System environment (fan fault) LED

6

System status LED

7

Beacon LED

The Cisco UCS 64108 Fabric Interconnect has two power supplies (redundant as 1+1) and three fans (redundant as 2+1).

Figure 6. Cisco UCS 64108 Fabric Interconnect Front View

1

Cooling fans

(hot swappable, 2+1 redundancy)

2

RS-232 serial console port (RJ-45 connector)

3

Network management port (RJ-45 connector)

4

USB port

5

Grounding pad for two-hole grounding lug (under protective label)

6

Power supplies

Two identical AC or DC PSUs, hot-swappable, 1+1 redundancy)

7

L1/L2 high-availability ports (RJ-45 connector)

8

Beacon LED

9

System status LED

Cisco UCS 6454 Fabric Interconnect

The Cisco UCS 6454 Fabric Interconnect (FI) is a 1-RU top-of-rack switch that mounts in a standard 19-inch rack such as the Cisco R Series rack.

The Cisco UCS 6454 Fabric Interconnect has 48 10/25 Gb SFP28 ports (16 unified ports) and 6 40/100 Gb QSFP28 ports. Each 40/100 Gb port can break out into 4 x 10/25 Gb uplink ports. The sixteen unified ports support 10/25 GbE or 8/16/32G Fibre Channel speeds.


Note


The Cisco UCS 6454 Fabric Interconnect supported 8 unified ports (ports 1 - 8) with Cisco UCS Manager 4.0(1) and 4.0(2), but with release 4.0(4) and later it supports 16 unified ports (ports 1 - 16).


The Cisco UCS 6454 Fabric Interconnect supports:

  • Maximum of 8 FCoE port channels

  • Or 4 SAN port channels

  • Or a maximum of 8 SAN port channels and FCoE port channels (4 each)

The Cisco UCS 6454 Fabric Interconnect also has one network management port, one console port for setting the initial configuration, and one USB port for saving or loading configurations. The FI also includes L1/L2 ports for connecting two fabric interconnects for high availability.

The Cisco UCS 6454 Fabric Interconnect also contains a CPU board that consists of:

  • Intel Xeon D-1528 v4 Processor, 1.6 GHz

  • 64 GB of RAM

  • 8 MB of NVRAM (4 x NVRAM chips)

  • 128 GB SSD (bootflash)

Figure 7. Cisco UCS 6454 Fabric Interconnect Rear View

1

Ports 1-16 (Unified Ports 10/25 Gbps Ethernet or FCoE or 8/16/32 Gbps Fibre Channel)

Note

 

When using Cisco UCS Manager releases earlier than 4.0(4), only ports 1-8 are Unified Ports.

2

Ports 17-44 (10/25 Gbps Ethernet or FCoE)

Note

 

When using Cisco UCS Manager releases earlier than 4.0(4), ports 9-44 are 10/25 Gbps Ethernet or FCoE.

3

Ports 45-48 (1/10/25 Gbps Ethernet or FCoE)

4

Uplink Ports 49-54 (40/100 Gbps Ethernet or FCoE)

Each of these ports can be 4 x 10/25 Gbps Ethernet or FCoE uplink ports when using an appropriate breakout cable.

The Cisco UCS 6454 Fabric Interconnect chassis has two power supplies and four fans. Two of the fans provide front to rear airflow.

Figure 8. Cisco UCS 6454 Fabric Interconnect Front View

1

Power supply and power cord connector

2

Fans 1 through 4, numbered left to right, when facing the front of the chassis.

3

L1 port, L2 port, RJ45, console, USB port, and LEDs

Port Breakout Functionality on Cisco UCS 64108 Fabric Interconnects

About Breakout Ports

Cisco UCS 64108 fabric interconnects support splitting a single 40/100G QSFP port into four 10/25G ports using a supported breakout cable. On the UCS 64108 fabric interconnect, by default, there are 12 ports in the 40/100G mode. These are ports 97 to 108. These 40/100G ports are numbered in a 2-tuple naming convention. For example, the second 40G port is numbered as 1/99. The process of changing the configuration from 40G to 10 G, or from 100G to 25G is called breakout, and the process of changing the configuration from [4X]10G to 40G or from [4X]25G to 100G is called unconfigure. These ports can be used as uplink port, appliance port, server port (using FEX), and FCoE storage port.

When you break out a 40G port into 10G ports or a 100G port into 25G ports, the resulting ports are numbered using a 3-tuple naming convention. For example, the breakout ports of the second 40-Gigabit Ethernet port are numbered as 1/99/1, 1/99/2, 1/99/3, 1/99/4.


Note


Cisco UCS Manager does not support connection of FEX, chassis, blade, IOM, or adapters (other than VIC adapters) to the uplink ports of Fabric Interconnect.


Starting with Cisco UCS Manager Release 4.2(3b), configuring the Ethernet breakout ports will not lead to Fabric Interconnect reboot.

The following image shows the rear view of the Cisco UCS 64108 fabric interconnect, and includes the ports that support breakout port functionality:

Figure 9. Cisco UCS 64108 Fabric Interconnect Rear View

1

Ports 1-16. Unified Ports can operate as 10/25 Gbps Ethernet or 8/16/32 Gbps Fibre Channel. FC ports are converted in groups of four.

Unified ports:

  • 10/25 Gbps Ethernet or FCoE

  • 8/16/32 Gbps Fibre Channel

2

Ports 1-96. Each port can operate as either a 10 Gbps or 25 Gbps Ethernet or FCoE SFP28 port.

3

Uplink Ports 97-108. Each port can operate as either a 40 Gbps or 100 Gbps Ethernet or FCoE port. When using a breakout cable, each of these ports can operate as 4 x 10 Gbps or 4 x 25 Gbps Ethernet or FCoE ports.

Ports 97 - 108 can be used to connect to Ethernet or FCoE uplink ports, and not to UCS server ports.

4

Ports 89-96

  • 10/25 Gbps Ethernet or FCoE

  • 1 Gbps Ethernet

5

System environment (fan fault) LED

6

System status LED

7

Beacon LED

Breakout Port Guidelines

The following are the guidelines for breakout functionality for Cisco UCS 64108 fabric interconnects:

  • The breakout configurable ports are ports 97-108.

  • You cannot configure the speed for each breakout port. Each breakout port is in auto mode.

  • Breakout ports are not supported as destinations for traffic monitoring.

  • Ports 97-108 at 40/100G can be configured as uplink, FCoE, or appliance port. Ports 97-108 after breakout to 10/25G can be configured as uplink, appliance, FCoE, or for direct-connect rack server connectivity.

Port Breakout Functionality on Cisco UCS 6454 Fabric Interconnects

About Breakout Ports

Cisco UCS 6454 fabric interconnects support splitting a single 40/100G QSFP port into four 10/25G ports using a supported breakout cable. These ports can be used only as uplink ports connecting to a 10/25G switch. On the UCS 6454 fabric interconnect, by default, there are 6 ports in the 40/100G mode. These are ports 49 to 54. These 40/100G ports are numbered in a 2-tuple naming convention. For example, the second 40G port is numbered as 1/50. The process of changing the configuration from 40G to 10 G, or from 100G to 25G is called breakout, and the process of changing the configuration from [4X]10G to 40G or from [4X]25G to 100G is called unconfigure.

When you break out a 40G port into 10G ports or a 100G port into 25G ports, the resulting ports are numbered using a 3-tuple naming convention. For example, the breakout ports of the second 40-Gigabit Ethernet port are numbered as 1/50/1, 1/50/2, 1/50/3, 1/50/4.

Starting with Cisco UCS Manager Release 4.2(3b), Ethernet breakout ports configuration will not lead to Fabric Interconnect reboot.

Starting with Cisco UCS Manager Release 4.1(3a), you can connect Cisco UCS Rack servers with VIC 1455 and 1457 adapters, to the uplink ports 49 to 54 (40/100 Gbps Ethernet or FCoE) in Cisco UCS 6454 Fabric Interconnects.


Note


Cisco UCS Manager does not support connection of FEX, chassis, blade, IOM, or adapters (other than VIC 1455 and 1457 adapters) to the uplink ports of Fabric Interconnect.


The following image shows the rear view of the Cisco UCS 6454 fabric interconnect, and includes the ports that support breakout port functionality:

Figure 10. Cisco UCS 6454 Fabric Interconnect Rear View

1

Ports 1-16 (Unified Ports 10/25 Gbps Ethernet or FCoE or 8/16/32 Gbps Fibre Channel)

2

Ports 17-44 (10/25 Gbps Ethernet or FCoE)

3

Ports 45-48 (1/10/25 Gbps Ethernet or FCoE)

4

Uplink Ports 49-54 (40/100 Gbps Ethernet or FCoE)

Breakout Port Guidelines

The following are the guidelines for breakout functionality for Cisco UCS 6454 fabric interconnects:

  • The breakout configurable ports are ports 49-54.

  • You cannot configure the speed for each breakout port. Each breakout port is in auto mode.

  • In Cisco UCS Manager Release 4.0(2), breakout ports are not supported as destinations for traffic monitoring.

  • Ports 49-54 at 40/100G can be configured as uplink, FCoE, or appliance port. Ports 49-54 after breakout to 10/25G can be configured as uplink, appliance, FCoE, or for direct-connect rack server connectivity.

Software Feature Configuration on Cisco UCS 6400 Series Fabric Interconnects

Cisco UCS Manager Release 4.0(1) and 4.0(2) introduced support for various software features on Cisco UCS 6454 Fabric Interconnects. Cisco UCS Manager Release 4.1 extends support for these features on Cisco UCS 64108 Fabric Interconnects. These software features are:

  • Switching Modes—Support for Ethernet and FC switching modes on Cisco UCS 6400 Series Fabric Interconnects .

  • MAC Security—Support for MAC security on Cisco UCS 6400 Series Fabric Interconnects.

  • Breakout Uplink Ports—Support for splitting a single 40/100G QSFP port into four 10/25G ports using a supported breakout cable. These ports can be used only as Ethernet uplink or FCoE uplink ports connecting to a 10/25G switch. They cannot be configured as server ports, FCoE storage ports, appliance ports or monitoring ports.

  • MTU Configuration—Cisco UCS 64108 Fabric Interconnects support MTU configuration for QOS drop class policy.

Cisco UCS 6400 Series Fabric Interconnects do not support the following software features:

  • Chassis Discovery Policy in Non-Port Channel Mode—Cisco UCS 6400 Series Fabric Interconnects support only Port Channel mode.

  • Chassis Connectivity Policy in Non-Port Channel Mode—Cisco UCS 6400 Series Fabric Interconnects support only Port Channel mode.

  • Multicast Hardware Hash—Cisco UCS 6400 Series Fabric Interconnects do not support multicast hardware hash.

  • Service Profiles with Dynamic vNICS—Cisco UCS 6400 Series Fabric Interconnects do not support Dynamic vNIC Connection Policies.

  • Multicast Optimize—Cisco UCS 6400 Series Fabric Interconnects do not support Multicast Optimize for QoS.

  • Port profiles and DVS Related Configurations—Cisco UCS 6400 Series Fabric Interconnects do not support configurations related to port profiles and distributed virtual switches (DVS).

Configuration of the following software features has changed for Cisco UCS 6400 Series Fabric Interconnects:

  • Unified Ports—Cisco UCS 6400 Series Fabric Interconnects support up to 16 unified ports, which can be configured as FC. These ports appear at the beginning of the module.

  • VLAN Optimization—On Cisco UCS 6400 Series Fabric Interconnects, you can configure VLAN port count optimization through port VLAN (VP) grouping when the PV count exceeds 16000. The following table illustrates the PV Count with VLAN port count optimization enabled and disabled on Cisco UCS 6400 Series Fabric Interconnect, Cisco UCS 6300 Series Fabric Interconnects.

    6300 Series FI

    6400 Series FI

    6500 Series FI (6536 FI)

    PV Count with VLAN Port Count Optimization Disabled

    16000

    16000

    16000

    PV Count with VLAN Port Count Optimization Enabled

    64000

    108000

    108000

    When a Cisco UCS 6400 Series Fabric Interconnect is in Ethernet switching mode:

    • The Fabric Interconnect does not support VLAN Port Count Optimization Enabled

    • The Fabric Interconnect supports 16000 PVs, similar to EHM mode, when set to VLAN Port Count Optimization Disabled

  • Limited Restriction on VLAN—Cisco UCS 6400 Series Fabric Interconnects reserve 128 additional VLANs for system purposes.

Cisco UCS 6300 Series Fabric Interconnects

Fabric Interconnect Features

A Cisco UCS 6300 Series Fabric Interconnect provides both network connectivity and management capabilities to a Cisco UCS system. The fabric interconnect provides Ethernet and Fibre Channel to the servers in the system, the servers connect to the fabric interconnect, and the fabric interconnect connects to the LAN or SAN.

Each Cisco UCS 6300 Series Fabric Interconnect runs Cisco UCS Manager to fully manage all Cisco UCS elements. The fabric interconnect supports full end-to-end 40-Gigabit capabilities in the fabric and enables 16-Gigabit Fibre Channel capabilities. High availability can be achieved when a Cisco UCS 6300 Series Fabric Interconnect is connected to another Cisco UCS 6300 Series Fabric Interconnect through the L1 or L2 port on each device.

The Cisco UCS 6300 Series Fabric Interconnect joins next-generation UCS products, including the following hardware:

  • Cisco UCS 6332 Fabric Interconnect, an Ethernet or Fibre Channel over Ethernet (FCoE) chassis with 32 40-Gigabit QSFP+ ports

  • Cisco UCS 6332-16UP Fabric Interconnect, an Ethernet, FCoE, and Fibre Channel chassis with 16 1- or 10-Gigabit SFP+ ports or 16 4-, 8-, or 16-Gigabit Fibre Channel ports, 24 40-Gigabit QSFP+ ports

  • Cisco 2304 IOM or Cisco 2304V2, I/O modules with 8 40-Gigabit backplane ports and 4 40-Gigabit uplink ports

  • Multiple VICs

Cisco UCS 6332 Fabric Interconnect

The Cisco UCS 6332 Fabric Interconnect is a 1-RU, top-of-rack switch with 32 40-Gigabit QSFP+ ports, one 100/1000 network management port, one RS-232 console port for setting the initial configuration, and two USB ports for saving or loading configurations. The switch also includes an L1 port and an L2 port for connecting two fabric interconnects to provide high availability. The switch mounts in a standard 19-inch rack, such as the Cisco R Series rack.

Cooling fans pull air front-to-rear. That is, air intake is on the fan side and air exhaust is on the port side.

Figure 11. Cisco UCS 6332 Fabric Interconnect Rear View

1

Port lane switch button, port lane LEDs, and L1 and L2 ports.

2

Ports 1–12 and ports 15–26 can operate as 40-Gbps QSFP+ ports, or as 4 x 10-Gbps SFP+ breakout ports.

Ports 1 - 4 support Quad to SFP or SFP+ (QSA) adapters to provide 1-Gbps/10 Gbps operation.

Ports 13 and 14 can operate as 40-Gbps QSFP+ ports. They cannot operate as 4 x 10-Gbps SFP+ breakout ports.

3

Ports 27–32 operate as 40-Gbps QSFP+ ports.

Figure 12. Cisco UCS 6332 Fabric Interconnect Front View


1

Power supply and power cord connector

2

Fans1 through 4, numbered left to right, when facing the front of the chassis.

3

Management, console, and USB ports, and LEDs.

Cisco UCS 6332-16UP Fabric Interconnect

The Cisco UCS 6332-16UP Fabric Interconnect is a 1-RU top-of-rack switch with 24 40-Gb QSFP+ ports, 16 10-Gb SFP ports, one 100/1000 network management port, one RS-232 console port for setting the initial configuration, and two USB ports for saving or loading configurations. The switch also includes an L1 port and an L2 port for connecting two fabric interconnects to provide high availability. The switch mounts in a standard 19-inch rack, such as the Cisco R Series rack.

Cooling fans pull air front-to-rear. That is, air intake is on the fan side and air exhaust is on the port side.

Figure 13. Cisco UCS 3223-16UP Fabric Interconnect Rear View

1

Port lane switch button, port lane LEDs, and L1 and L2 ports.

2

Ports 1–16 are Unified Ports (UP) that operate either as 1- or 10-Gbps SFP+ fixed Ethernet ports; or as 4-, 8-, or 16-Gigabit Fibre Channel ports.

3

Ports 17–34 operate either as 40-Gbps QSFP+ ports, breakout mode for 4 x 10-Gigabit SFP+ breakout ports, or QSA for 10G.

4

Ports 35–40 operate as 40-Gbps QSFP+ ports.

Figure 14. Cisco UCS 6332-16UP Fabric Interconnect Front View


1

Power supply and power cord connector

2

Fans1 through 4, numbered left to right, when facing the front of the chassis.

3

Management, console, and USB ports, and LEDs.

Ports on the Cisco UCS 6300 Series Fabric Interconnects

Ports on the Cisco UCS 6300 Series Fabric Interconnects can be configured to carry either Ethernet or Fibre Channel traffic. These ports are not reserved. They cannot be used by a Cisco UCS domain until you configure them.


Note


When you configure a port on a fabric interconnect, the administrative state is automatically set to enabled. If the port is connected to another device, this may cause traffic disruption. You can disable the port after it has been configured.


The following table summarizes the third generation ports for the Cisco UCS fabric interconnects.

Cisco UCS Mini

Third Generation

Item

Cisco UCS 6324

Cisco UCS 6332

Cisco UCS 6332-16UP

Description

Fabric Interconnect with 4 unified ports and 1 scalability port

32–Port Fabric Interconnect

40–Port Fabric Interconnect

Form factor

1 RU

1 RU

1 RU

Number of fixed 40 GB Interfaces

6(Ports 17–32)

6(Ports 35–40)

Number of 1GB/10GB Interfaces (depending on the SFP module installed)

All

Ports 5–26 using breakout cable

Ports 17–34 using breakout cable

Unified Ports (8 Gb/s, FC, FCoE)

4

None

Ports 1–16

Compatibility with all IOMs

All

All

All

Expansion Slots

None

None

None

Fan Modules

4

4

4

Power Supplies

2 (AC/DC available)

2 (AC/DC available)


Note


Cisco UCS 6300 Series Fabric Interconnects support breakout capability for ports. For more information on how the 40G ports can be converted into four 10G ports, see Port Breakout Functionality on Cisco UCS 6300 Series Fabric Interconnects.


Port Modes

The port mode determines whether a unified port on the fabric interconnect is configured to carry Ethernet or Fibre Channel traffic. You configure the port mode in Cisco UCS Manager. However, the fabric interconnect does not automatically discover the port mode.

Changing the port mode deletes the existing port configuration and replaces it with a new logical port. Any objects associated with that port configuration, such as VLANs and VSANS, are also removed. There is no restriction on the number of times you can change the port mode for a unified port.

Port Types

The port type defines the type of traffic carried over a unified port connection.

By default, unified ports changed to Ethernet port mode are set to the Ethernet uplink port type. Unified ports changed to Fibre Channel port mode are set to the Fibre Channel uplink port type. You cannot unconfigure Fibre Channel ports.

Changing the port type does not require a reboot.

Ethernet Port Mode

When you set the port mode to Ethernet, you can configure the following port types:

  • Server ports

  • Ethernet uplink ports

  • Ethernet port channel members

  • FCoE ports

  • Appliance ports

  • Appliance port channel members

  • SPAN destination ports

  • SPAN source ports


    Note


    For SPAN source ports, configure one of the port types and then configure the port as SPAN source.


Fibre Channel Port Mode

When you set the port mode to Fibre Channel, you can configure the following port types:

  • Fibre Channel uplink ports

  • Fibre Channel port channel members

  • Fibre Channel storage ports

  • SPAN source ports


    Note


    For SPAN source ports, configure one of the port types and then configure the port as SPAN source.


Port Breakout Functionality on Cisco UCS 6300 Series Fabric Interconnects

About Breakout Ports

Cisco UCS fabric interconnect 6300 series supports splitting a single QSFP port into four 10G ports using a supported breakout cable. By default, there are 32 ports in the 40G mode. These 40G ports are numbered in a 2-tuple naming convention. For example, the second 40G port is numbered as 1/2. The process of changing the configuration from 40G to 10G is called breakout and the process of changing the configuration from [4X]10G to 40G is called unconfigure.

When you break out a 40G port into 10G ports, the resulting ports are numbered using a 3-tuple naming convention. For example, the breakout ports of the second 40-Gigabit Ethernet port are numbered as 1/2/1, 1/2/2, 1/2/3, 1/2/4.

The following image shows the front view for the Cisco UCS 6332 series fabric interconnects, and includes the ports that may support breakout port functionality:

Figure 15. Cisco UCS 6332 Series Fabric Interconnects Front View

1

L1 and L2 high availability ports

2

28 X 40G QSFP ports ( 98 X 10G SFP ports)

Note

 
  • QSA module is required on ports 13–14

  • A QSFP to 4XSFP breakout cable is required for 10G support.

3

6 X 40G QSFP ports

The following image shows the front view for the Cisco UCS 6332-16UP series fabric interconnects, and includes the ports that may support breakout port functionality:

Figure 16. Cisco UCS 6332-16UP Series Fabric Interconnects Front View

1

L1 and L2 high availability ports

2

16 X 1/10G SFP (16 X 4/8/16G FC ports)

3

18 X 40G QSFP(72 X 10G SFP+)

Note

 
  • A QSFP to 4XSFP breakout cable is required for 10G support.

4

6 X 40G QSFP ports

The following image shows the rear view of the Cisco UCS 6300 series fabric interconnects.

Figure 17. Cisco UCS 6300 Series Fabric Interconnects Rear View

1

Power supply

2

Four fans

3

Power supply

4

Serial ports

Breakout Port Constraints

The following table summarizes the constraints for breakout functionality for Cisco UCS 6300 series fabric interconnects:

Cisco UCS 6300 Series Fabric Interconnect Series

Breakout Configurable Ports

Ports without breakout functionality support

Cisco UCS 6332

1–12, 15–26

13–14, 27–32

Note

 
  • Auto-negotiate behavior is not supported on ports 27–32.

Cisco UCS 6332-16UP

17–34

1–16, 35–40

Note

 
  • Auto-negotiate behavior is not supported on ports 35–40


Important


Up to four breakout ports are allowed if QoS jumbo frames are used.


Cisco UCS Chassis

Cisco UCS Manager Release 3.1(1) and later releases provide support for Cisco UCS 5108 Blade Server Chassis

Chassis Management provides details on managing the chassis through Cisco UCS Manager.

Cisco UCS 5108 Blade Server Chassis

The Cisco UCS 5108 Blade Server Chassis, is six rack units (6RU) high, can mount in an industry-standard 19-inch rack, and uses standard front-to-back cooling. A chassis can accommodate up to eight half-width, or four full-width Cisco UCS B-Series Blade Servers form factors within the same chassis. By incorporating unified fabric and fabric-extender technology, the Cisco Unified Computing System enables the chassis to:

  • Have fewer physical components

  • Require no independent management

  • Be more energy efficient than a traditional blade-server chassis

The Cisco UCS 5108 Blade Server Chassis is supported with all generations of fabric interconnects.

Cisco UCS Mini Infrastructure

The Cisco UCS Mini solution extends the Cisco UCS architecture into environments with requirements for smaller domains, including branch and remote offices, point-of-sale locations, and smaller IT environments. Cisco UCS Mini has three main infrastructure components:

  • Cisco UCS 6324 fabric interconnect

  • Cisco UCS blade server chassis

  • Cisco UCS blade or rack mount servers

Figure 18. Cisco UCS Mini


In the Cisco UCS Mini solution, the Cisco UCS 6324 fabric interconnect is collapsed into the IO Module form factor, and is inserted into the IOM slot of the blade server chassis. The Cisco UCS 6324 fabric interconnect has 24 10G ports available on it. Sixteen of these ports are server facing, two 10G ports are dedicated to each of the eight half width blade slots. The remaining eight ports are divided into groups of four 1/10G Enhanced Small Form-Factor Pluggable (SFP+) ports and one 40G Quad Small Form-factor Pluggable (QSFP) port, which is called the 'scalability port'.

Cisco UCS Manager Release 3.1(1) introduces support for a second UCS 5108 chassis to an existing single-chassis Cisco UCS 6324 fabric interconnect setup. This extended chassis enables you to configure an additional 8 servers. Unlike the primary chassis, the extended chassis supports IOMs. Currently, it supports UCS-IOM-2204XP and UCS-IOM-2208XP IOMs. The extended chassis can only be connected through the scalability port on the FI-IOM.


Important


Currently, Cisco UCS Manager supports only one extended chassis for UCS Mini.


Cisco UCS Infrastructure Virtualization

Cisco UCS is a single integrated system with switches, cables, adapters, and servers that are all tied together and managed by unified management software. One capability that enables this unification is the ability to virtualize every component of the system at every level. Switch port, cables, adapter, and servers can all be virtualized. Because of the virtualization capabilities at every component of the system, you have the unique capability to provide rapid provisioning of any service on any server on any blade through a system that is wired once. The following image illustrates these virtualization capabilities.

Figure 19. Virtualization Capabilities of Cisco UCS


Switch Port Virtualization

The physical interfaces provide physical connectivity for what are logical virtual interfaces on the fabric interconnects-virtual Fibre Channel interfaces (vFC) and virtual Ethernet interfaces (vEth). The logical connectivity to a server is provided through these virtual interfaces.

Cable Virtualization

The physical cables that connect to physical switch ports provide the infrastructure for logical and virtual cables. These virtual cables connect to virtual adapters on any given server in the system.

Adapter Virtualization

On the server, you have physical adapters, which provide physical infrastructure for virtual adapters. A virtual network interface card (vNIC) or virtual host bus adapter (vHBA) logically connects a host to a virtual interface on the fabric interconnect and allows the host to send and receive traffic through that interface. Each virtual interface in the fabric interconnect corresponds to a vNIC.

An adapter that is installed on the server appears to the server as multiple adapters through standard PCIe virtualization. When the server scans the PCIe bus, the virtual adapters that are provisioned appear to be physically plugged into the PCIe bus.

Server Virtualization

Server virtualization provides you with the ability of stateless servers. As part of the physical infrastructure, you have physical servers. However, the configuration of a server is derived from the service profile to which it is associated. All service profiles are centrally managed and stored in a database on the fabric interconnect. A service profile defines all the settings of the server, for example, the number of adapters, virtual adapters, the identity of these adapters, the firmware of the adapters, and the firmware of the server. It contains all the settings of the server that you typically configure on a physical machine. Because the service profile is abstracted from the physical infrastructure, you can apply it to any physical server and the physical server will be configured according to the configuration defined in the service profile. Cisco UCS Manager Server Management Guide provides detailed information about managing service profiles.