Technical Specifications
The following sections describe the technical specifications for the Cisco SIP IP phone:
•
Physical and Operating Environment Specifications
•
Cable Specifications
•
Regulatory Safety Compliance
•
Connections Specifications
Physical and Operating Environment Specifications
The following table lists the physical and operating specifications of the Cisco SIP IP phone.
Table C-1 Cisco SIP IP Phone Operational and Physical Specifications
|
|
Operating temperature |
32 to 104 ° F (0 to 40 ° C) |
Operating relative humidity |
10 to 95% (noncondensing) |
Storage temperature |
14 ° to 140 ° F (-10 to 60 ° C) |
Height |
8 in. (20.32 cm) |
Width |
10.5 in. (26.67 cm) |
Depth |
6 in. (15.24 cm) |
Weight |
3.5 lb (1.6 kg) |
Power |
100-240 VAC, 50-60 Hz, 0.5 A—when using the AC adapter 48 Vdc, 0.2 A—when using the in-line power over the network cable |
Cables |
Two (2) pair of Category 3 for 10 Mbps cables Two (2) pair of Category 5 for 100 Mbps cables |
Distance Requirements |
As supported by the Ethernet Specification, it is assumed that most sets that are deployed in the field will be within 100 m (330 ft.) of a phone closet. |
Cable Specifications
The following cables are required to connect the Cisco SIP IP phone:
•
RJ-11 for the handset connection
•
RJ-45 jack for the LAN connection (labeled "10/100 SW").
•
RJ-45 jack for a second 10Base-T compliant connection (labeled "10/100 PC").
•
48-volt power connector. The diameter of the center pin in the phone power jack (Switchcraft 712A) is .1 inches (2.5 mm). The center pin is positive (+) voltage. The miniature power plug required to mate with the power jack on the phone is a Switchcraft 760 or equivalent.
Regulatory Safety Compliance
The Cisco IP Phone models 7960, 7940, and 7910 meet the following regulatory safety and compliance approvals:
•
CE Marking
•
Safety
–
UL1950
–
CSA C22.2 No. 950
–
EN 60950
–
IEC 60950
–
AS/NZS 3260
–
TS001
•
EMC
–
AS/NZS 3548 Class B
–
VCCI Class B
–
FCC (47CFR) Part 15 Class B
–
EN 55022, Class B
•
Telecom
–
IC CS-03
–
FCC (47CFR) Part 68
Figure C-1 contains the FCC Class B Declaration for the Cisco IP Phone 7960, 7940, 7910, and 7910+SW.
Figure C-1 FCC Class B Declaration
Connections Specifications
The Cisco SIP IP phone has two RJ-45 ports that each support 10/100 Mbps half- or full-duplex connections to external devices—the network port and access port. You can use either Category 3 or 5 cabling for 10 Mpbs connections, but use Category 5 for 100 Mbps connections. On both the LAN-to-phone port (left RJ-45 port facing the back of the phone) and PC-to-phone port (right port), use full-duplex to avoid collisions. Use the LAN-to-phone port to connect the phone to the network a LAN-to-phone jack. Use the PC-to-phone port to connect a network device, such as a computer, to the phone.