Cisco AS5800 Specifications
System Specifications
A single Cisco AS5800 consists of a Cisco 5814 dial shelf and a Cisco 7206 router shelf. describes the Cisco 5814 dial shelf specifications, and shows the router shelf network processor card factory-installed DRAM configuration.
For Cisco 7206 router shelf physical specification information, refer to the Cisco 7206 Installation and Configuration Guide that shipped with your router shelf.
Table A-1 Cisco 5814 Dial Shelf Specifications
Description
|
Specification
|
Dimensions (H x W x D)
|
28.0 x 17.4 x 23.6 in. (71.1 x 44.2 x 59.9 cm)
|
Component Weights
|
|
Cisco 5814 dial shelf (with filter module, blower assembly, and 14 cards)
|
278 lb (126.1 kg)
|
Cisco 5814 dial shelf (with filter module, blower assembly, and no cards installed)
|
114 lb (51.7 kg)
|
Cisco 5814 dial shelf chassis (empty)
|
62 lb (28.1 kg)
|
Dial shelf backplane
|
2.5 lb (1.1 kg)
|
Dial shelf trunk card
|
8 lb each (3.6 kg)
|
Dial shelf modem card
|
8 lb each (3.6 kg)
|
Component Weight (continued)
|
|
Dial shelf controller card
|
8.5 lb each (3.8 kg)
|
Dial shelf blower assembly
|
27.5 lb (12.5 kg)
|
Dial shelf DC power-entry module
|
8 lb each (3.6 kg)
|
Dial shelf filter module
|
5.5 lb (2.5 kg)
|
AC-input power shelf (empty)
|
18.5 lb (8.4 kg)
|
AC-input power supply
|
14 lb each (6.4 kg)
|
AC-input power shelf safety cover
|
3.5 lb (1.6 kg)
|
Environmental Requirements
|
|
Operational temperature Maximum operating temperature Acceptable temperature rise Maximum heat generated
|
23 to 104°F (-5° C to 40° C) 23 to 120°F (-5° C to 50° C) (not more than 72 hours) 30°C per hour 8,000 BTU
|
Backplane
|
14 slots
|
Power
|
44A at -48 VDC
|
Frequency
|
50/60 Hz
|
Heat dissipation
|
2,000W (6820 Btu/hr)
|
AC-input voltages and frequency
|
200 to 240 VAC 50 to 60 Hz
|
AC voltage and current
|
200 VAC at 16A maximum1 wide input with power factor correction (PFC) 240 VAC at 7A maximum
|
AC cable
|
12 American Wire Gauge (AWG), with three leads, an IEC-320 receptacle on the power supply end, and a country-dependent plug on the power source end
|
DC-input voltage and current
|
-48 VDC to -60 VDC
|
DC-input cable
|
6 AWG for North American environments 10 mm2 wire for international environments when connecting directly to a DC power source
|
DC voltages supplied and maximum, steady-state current (AC- and DC-input)
|
-48V, 54A maximum
|
Relative humidity
|
|
Operating Nonoperating
|
10 to 90%, noncondensing 10 to 95%, noncondensing
|
Factory-Installed Memory
|
|
Dial shelf controller card
|
32-MB DRAM
|
T1 or E1 trunk card (dial shelf)
|
32-MB DRAM
|
Modem card (dial shelf)
|
16-MB DRAM
|
Regulatory Compliance
|
|
Agency approvals
|
Safety: UL 1950, CSA 22.2 No. 950, EN60950, AUSTEL TS001, AS/NZS 3260, IEC 950
Emissions: CFR 47 Part 15 Class A (FCC), CISPR22 Class B, EN55022 Class B, AS/NRZ 3548 Class B, ICES003, VCCI Class B
Immunity: IEC 1000-3-2, IEC 1000-3-3, IEC-1000-4-2, IEC-1000-4-3, IEC-1000-4-4, IEC-1000-4-5, IEC-1000-4-6, IEC-1000-4-11, EN50082-1, EN50082-2
For additional compliance information refer to the Regulatory Safety and Compliance Information documents that shipped with your system.
|
Table A-2 Router Shelf Network Processor Card DRAM SIMM Configurations
Total DRAM
|
DRAM Bank 0
|
Quantity
|
DRAM Bank 1
|
Quantity
|
Product Number
|
128 MB
|
U18 and U25 or U11 and U25
|
2 32-MB SIMMs
|
U4 and U12 or U42 and U52
|
2 32-MB SIMMs
|
MEM-NPE-128MB
|
Backplane Specifications
lists the backplane DC power specifications.
Table A-3 Backplane—DC Power Requirements
Description
|
Specification
|
Input voltage
|
Minimum Minimum/Nominal Nominal Maximum/Nominal Maximum
|
-20 (10 ms) -38 VDC -48 VDC -72 VDC -75 (IS)
|
Output voltage
|
Maximum Nominal Minimum
|
-38 VDC -48 VDC -75 VDC
|
Current
|
42 A
|
Minimum (SS) Maximum (SS) Peak (2 sec)
|
3 A 60 A 80 A
|
Circuit breaker
|
50 A
|
lists the backplane environmental specifications.
Table A-4
Description
|
Specification
|
Dimensions (H x W)
|
12.75 x 16.75 in. (32.4 x 42.5 cm)
|
Cooling
|
Maximum inlet air temperature is 131° F (55° C)
|
Temperature
|
Operating Nonoperating
|
23 to 131° F (-5 to 55° C) -13 to 158° F (-25 to +70° C)
|
Humidity
|
Operating Nonoperating
|
10 to 90%, noncondensing 10 to 95%, noncondensing
|
Altitude
|
Operating Nonoperating
|
9,843 ft (3,000 m) at 104° F (40° C) 15,000 ft (4,570 m) over allowable temperature range
|
Thermal shock
|
Operating Nonoperating
|
23 to 113° F (-5 to 45° C at 0.5° C) per minute -13 to 158° F (-25 to 70° C) with changeover time between 2 and 3 min
|
Vibration
|
Operating Nonoperating
|
1.12 g from 3 to 500 Hz 2 g from 3 to 500 Hz
|
Ripple and noise
|
200 mV
|
Battery feed noise
|
3 KHz band between 10 KHz and 20 MHz
|
Voice frequency noise Radio frequency noise
|
70 dBrnC 500 mV RMS
|
Long-term voltage drift
|
± -0.5%
|
Backplane—Environmental Specifications
Blower Assembly Specifications
lists blower assembly DC power requirements.
Table A-5 Blower Assembly—DC Power Requirements
Power
|
Specification
|
Voltage to backplane
|
Maximum Nominal Minimum
|
-38 VDC -48 VDC -75 VDC
|
Current
|
Minimum (SS) Nominal (SS) Maximum (SS) Peak (2 sec)
|
3.0 A 42.0 A 54.0 A 60.0 A
|
lists the blower assembly environmental specifications, which are designed to meet NEC, NEBS, and ETSI requirements.
Table A-6 Blower Assembly—Environmental Specifications
Specification
|
Description
|
Cooling
|
Maximum inlet air temperature is 131° F (55° C)
|
Audible noise
|
Maximum acoustic noise level is 60 dBa
|
Temperature
|
Operating Nonoperating
|
23 to 131° F (-5 to 55° C) -13 to 158° F (-25 to 70° C)
|
Humidity
|
Operating Nonoperating
|
10 to 90%, noncondensing 10 to 95%, noncondensing
|
Altitude
|
Operating Nonoperating
|
9,843 ft (3,000 m) at 104° F (40° C) 15,000 ft (4,570 m) over allowable temperature range
|
Thermal shock
|
Operating Nonoperating
|
23 to 113° F at 32.9° F (-5 to 45° C at 0.5° C) per minute -13 to 158° F (-25 to 70° C) with changeover time between 2 and 3 min
|
Vibration
|
Operating Nonoperating
|
1.12 g from 3 to 500 Hz 2 g from 3 to 500 Hz
|
Regulatory compliance
|
ENG-5769 UL 1950 CSA 22.2-950-936 EN 60 950 BABT AUSTEL IEC-801 Telcordia Technologies (formerly Bellcore) NEBS TR-NWT-000063 Telcordia Technologies (formerly Bellcore) NEBS TR-NWT-001089
|
Dial Shelf Controller Card Specifications
lists dial shelf controller card environmental specifications.
Table A-7 Dial Shelf Controller Card Environmental Specifications
Description
|
Specification
|
Cooling
|
Maximum inlet air temperature is 131° F (55° C)
|
Temperature
|
|
Operating Nonoperating
|
23 to 131° F (-5 to 55° C) -13 to 158° F (-25 to 70° C)
|
Humidity
|
|
Operating Nonoperating
|
10 to 90%, noncondensing 10 to 95%, noncondensing
|
Altitude
|
|
Operating Nonoperating
|
9,843 ft (3,000 m) at 104° F (40° C) 15,000 ft (4,570 m) over allowable temperature range
|
Thermal shock
|
|
Operating
Nonoperating
|
23 to 113° F (-5 to 45° C at 0.5° C) per minute -13 to 158° F (-25 to 70° C) with change-over time between 2 and 3 minutes
|
Vibration
|
|
Operating Nonoperating
|
1.12 Grms from 3 to 500 Hz 2 Grms from 3 to 500 Hz
|
Ripple and noise
|
200 mV
|
Battery feed noise
|
3kHz band between 10KHz and 20 MHz
|
Voice frequency noise Radio frequency noise
|
70 dBrnC 500 mV RMS
|
Long-term voltage drift
|
± -0.5%
|
DC PEM Specifications
The PEMs provide -48 VDC power, which is distributed through the filter module to the dial shelf backplane. The analog isolators in the filter module are provided with 15 VDC. The PEMs suffer no damage if any or all outputs have no load (no load occurs when there are no cards plugged into the backplane) or if the maximum input voltage is exceeded; however, input voltages that exceed 75 V eventually trip the PEM 60 A circuit breaker, and you might have to reset the breaker as needed.
lists DC output voltage and current specifications.
Table A-8 Power Entry Module Power Specifications
Power
|
Description
|
Voltage to backplane
|
Maximum Nominal Minimum
|
-38 VDC -48 VDC -75 VDC
|
Current
|
Minimum (SS) Nominal (SS) Maximum (SS) Peak (2 sec)
|
3 A 42 A 54 A 60 A
|
Circuit breaker
|
50A
|
lists the DC-input power supply environmental specifications, which are designed to meet NEC, NEBS, and ETSI requirements.
Table A-9 Power Entry Module Environmental Specifications
Specification
|
Description
|
Cooling
|
Maximum inlet air temperature is 131° F (55° C)
|
Temperature
|
Operating Nonoperating
|
23 to 131° F (-5 to 55° C) -13 to 158° F (-25 to +70° C)
|
Humidity
|
Operating Nonoperating
|
10 to 90%, noncondensing 10 to 95%, noncondensing
|
Altitude
|
Operating Nonoperating
|
9,843 ft (3,000 m) at 104° F (40° C) 15,000 ft (4,570 m) over allowable temperature range
|
Thermal shock
|
Operating Nonoperating
|
23° F to 113° F (-5° C to 45° C) at 0.5° C per minute -13° F to 158° F (-25° C to 70° C) with changeover time between 2 and 3 min
|
Vibration
|
Operating Nonoperating
|
1.12 g from 3 to 500 Hz 2 g from 3 to 500 Hz
|
Regulatory compliance
|
ENG-5769 UL 1950 CSA 22.2-950-95 EN 60 950 ACA TS001, AS3260
|
Filter Module Specifications
lists the filter module DC power requirements.
Table A-10 Filter—DC Power Requirements
Description
|
Specification
|
Input voltage
|
Minimum Minimum/Nominal Nominal Maximum/Nominal Maximum
|
-20 (10 mS) -38 VDC -48 VDC -72 VDC -75 (IS)
|
Output voltage
|
Maximum Nominal Minimum
|
-38 VDC -48 VDC -75 VDC
|
Current
|
Minimum (SS) Nominal (SS) Maximum (SS) Peak (2 sec)
|
3 A 42 A 60 A 80 A
|
Circuit breaker
|
50 A
|
lists the filter module environmental specifications.
Table A-11 Filter Module Environmental Specifications
Specification
|
Description
|
Cooling
|
Maximum inlet air temperature is 131° F (55° C)
|
Temperature
|
Operating Nonoperating
|
23° F to 131° F (-5° C to 55° C) -13° F to 158° F (-25° C to 70° C)
|
Humidity
|
Operating Nonoperating
|
10% to 90%, noncondensing 10% to 95%, noncondensing
|
Altitude
|
Operating Nonoperating
|
9,843 ft (3,000 m) at 104° F (40° C) 15,000 ft (4,570 m) over allowable temperature range
|
Thermal shock
|
Operating Nonoperating
|
23° F to 113° F (-5° C to 45° C at 0.5° C) per minute -13° F to 158° F (-25° C to 70° C) with changeover time between 2 and 3 minutes
|
Vibration
|
Operating Nonoperating
|
1.12 g from 3 to 500 Hz 2 g from 3 to 500 Hz
|
Ripple and noise
|
200 mV
|
Battery feed noise
|
3 kHz band between 10 kHz and 20 MHz
|
Voice frequency noise Radio frequency noise
|
70 dBrnC 500 mV RMS
|
Long-term voltage drift
|
± -0.5%
|
Regulatory compliance
|
ENG-5769 UL 1950 CSA 22.2-950-95 EN 60 950 ACA TS001, AS3260 IEC-801 Telcordia Technologies (formerly Bellcore) NEBS TR-NWT-000063 Telcordia Technologies (formerly Bellcore) NEBS TR-NWT-001089
|
AC Power Module Specifications
The AC-input power supply operates between 200 and 240 VAC input voltage and supplies -48 VDC to the dial shelf. The AC-input power supply uses a power factor corrector (PFC) that automatically adjusts for the input voltage being supplied.
lists the AC-input power supply specifications.
Table A-12 AC-Input Power Supply—Specifications
Description
|
Specification
|
Input
|
|
Input power requirement
|
2666.66 volt amps VA
|
Input voltage
|
200 to 240 VAC
|
Input frequency
|
50 to 60 Hz
|
Power factor
|
0.90 at 50% of full load; 0.99 at full load
|
Output
|
|
Power output
|
2000W with a maximum configuration and one or two AC-input power supplies
|
Voltage out (VO) set point:
|
-48.0 VDC typical. Frame ground strappable to either output terminal.
|
Current out (IO) rated:
|
0 to 41.6A DC; 2000W maximum
|
Output current limit
(steady state)
|
58.1A DC maximum
|
Efficiency
|
88% at full load, 240 VAC, with ORing diode
|
DC-output stud torque
|
25 in. lb
|
Environmental Characteristics
|
|
Dimensions (H x W x D)
|
5.25 x 17 x 14.4 in. (13.32 x 43.2 x 35.88 cm)
|
Weight
|
Per power supply: 14.5 lb (6.6 kg)
Empty power shelf: 18 lb (8.16 kg)
|
Heat dissipation
|
1037 Btu/hr
|
AC power cable supplied
|
12 AWG; 16A1
|
DC interconnect cable supplied
|
6 AWG, 2 pairs (black and red)
|
Storage temperature
|
25.8 to 185 °F (-40 to 85 °C)
|
Operating Temperature (air inlet to power unit)
|
32 to 122 °F (0 to 50 °C) airflow front to back with 3 clearance for exhaust air in unpressurized enclosure
|
Acoustics
|
60 dBA typical; sound pressure level measured at 1 m
|
Humidity (noncondensing)
|
5% to 95%
|
Altitude
|
-200 to 13,000 ft (-61 to 3,962 m); adjust temperature at -7 °C per 1000 ft. above 8000 ft
|
Shock and Vibration
|
Lucent L-533809
|
ESD
|
IEC1000-4-2
|
Reliability (at 40 °C, 200 VAC, 1600 W)
|
7500 FITS per TR-EOP-000332
1.5 x 105 hours MTBF per RIN
|
Regulatory compliance
|
|
Agency approvals
|
CE UL CSA VDE
For compliance information refer to the Cisco AS5800 Universal Access Server Regulatory Compliance and Safety Information document that shipped with your system.
|
Enhanced Power Supply Specifications
The power supply for the enhanced AC-input power shelf operates between 200 and 240 VAC input voltage and supplies -48 VDC to the dial shelf. The power supply for the enhanced AC-input power shelf uses a power factor corrector (PFC) that automatically adjusts for the input voltage being supplied.
lists the specifications for the enhanced AC-input power shelf AC-input power supply.
Table A-13 Enhanced AC-Input Power Supply Specifications
Description
|
Specification
|
Input
|
|
Input power requirement
|
2666.66 volt amps (VA)
|
Input voltage
|
200 to 240 VAC1
|
Input frequency
|
50 to 60 hertz (Hz)
|
Power factor
|
0.90 at 50% of full load; 0.99 at full load
|
Output
|
|
Power output
|
2000W with a maximum configuration and one or two AC-input power supplies
|
Voltage out (VO) set point:
|
-48.0 VDC2 typical
|
Current out (IO) rated:
|
0 to 41.6 amps DC; 2000W maximum
|
Output current limit
(steady state)
|
58.1 amps DC maximum
|
Efficiency
|
88% at full load, 240 VAC with ORing diode
|
DC-output stud torque
|
25 in. lb
|
Environmental Characteristics
|
|
Dimensions (H x W x D)
|
5.25 x 17.32 x 13.6 in. (13.32 x 44 x 34.5 cm)
|
Weight
|
Per power supply: 11 lb (5 kg)
Empty power shelf: 14 lb (6.4 kg)
|
Heat dissipation
|
7755 Btu/hr
|
AC power cable supplied
|
12 American Wire Gauge (AWG), 16-amp3
|
DC interconnect cable supplied
|
6 AWG, 2 pairs (black and red)
|
Storage temperature
|
25.8 to 185 °F (-40 to 85 °C)
|
Operating Temperature (air inlet to power unit)
|
32 to 122 °F (0 to 50 °C) airflow front to back with clearance for exhaust air in unpressurized enclosure
|
Acoustics
|
60 dBA typical; sound pressure level measured at 1 m
|
Humidity (noncondensing)
|
5 to 95%
|
Altitude
|
-200 to 13,000 ft (-61 to 3,962 meters); derate at -7 °C/1000 ft above 8000 ft
|
Shock and Vibration
|
Cisco Systems ENG-3396
|
ESD
|
IEC1000-4-2
|
Reliability (at 25 °C, 220 VAC, 2000 W)
|
150k hours MTBF
|
Regulatory compliance
|
|
Agency approvals
|
CE UL CSA VDE
For compliance information see the Cisco AS5800 Universal Access Server Regulatory Compliance and Safety Information document that shipped with your system.
|
Cabling Specifications
This section describes and provides pinout information for the cables available for the Cisco AS5800 that connect to the dial shelf, the router shelf, and power modules and supplies. For pinouts and specifications of cables that connect to dial shelf ingress cards (T1/E1, T3) refer to the Cisco AS5800 Universal Access Server Dial Shelf Card Guide.
Dial Shelf Interconnect Port Adapter Cables
The dial shelf interconnect port adapter contains a single RJ-45 receptacle, which is used to connect the router shelf to the dial shelf. The cable used for this connection is a Cisco proprietary cable, customized with jackscrews to secure the connection. You must use this specially designed cable, which shipped with your dial shelf interconnect port adapter, to connect the dial shelf to the router shelf.
Caution Disconnecting this cable while the system is operating will result in a loss of all calls.
Figure A-1 shows the dial shelf interconnect cable with jackscrew connectors.
Figure A-1 Dial Shelf Interconnect Cable with Jackscrew Connectors
AC-Input Power Shelf Cables
The AC-input power shelf is equipped with four types of cables:
•Two AC power cords for AC input
•Two DC interconnect cables for DC output
•One DB-25 to DB-9 monitor cable for status signaling
•Two ground cables for grounding the power shelf to the dial shelf
The AC-input connection uses a 15A/240 VAC power cord in Europe, Asia, and North America. The 15A connectors on the AC-input power shelf are incompatible with 15A power strips used in most equipment racks and with the power source used for the router shelf.
Caution Do not plug the AC-input power shelf into the same power source as the AC router shelf.
Note Wiring codes prevent the AC-input power cable from being used with the power strips in equipment racks.
shows 15-A North American power connectors.
Figure A-2 15-Amp AC Power Cord Connector and Plug, and 15-Amp Receptacle
The European or Asian power cable is rated at 16A/250-VAC. The source-side power cable connector is either shipped to match local compliance, or wired at the installation site.
The DC interconnect cables (see Figure A-3) supplied with your AC-input power shelf attach to bus terminal studs in the AC-input power shelf using ring-lug connectors; the cables then connect to the DC terminal blocks in each PEM.
Figure A-3 DC Interconnect Cables
The monitor cable has a DB-25 connector on the AC-input power shelf end and a DB-9 connector on the dial shelf end that connects to the dial shelf filter module. Figure A-4 shows the monitor cable connectors and receptacles. The pinout of the monitor cable varies slightly between the standard and enhanced AC power shelves.
Figure A-4 Monitor Cable
describes the cable pinout used with the AC power shelf.
Table A-14 Monitor Cable Pinout —AC Power Shelf
DB-9 Pin
|
Signal Description
|
|
1
|
AC power failure warning signal
|
11
|
2
|
AC power shelf overtemperature signal
|
10
|
3
|
AC power shelf fault signal
|
9
|
4
|
Ground
|
8
|
6
|
Ground
|
13
|
7
|
Ground
|
19
|
8
|
Ground
|
19
|
9
|
AC power shelf missing module
|
12
|