Table Of Contents
Configuring Interfaces
Information About Interfaces
Interface Description
Interface Modes
E Port
F Port
FL Port
NP Ports
TL Port
TE Port
TF Port
TNP Port
SD Port
ST Port
Fx Port
B Port
Auto Mode
Interface States
Administrative States
Operational States
Reason Codes
Graceful Shutdown
Port Administrative Speeds
Autosensing
Frame Encapsulation
Beacon LEDs
Speed LEDs
Bit Error Thresholds
SFP Transmitter Types
TL Ports
TL Port ALPA Caches
Port Guard
Port Monitor
Port Monitor Port Guard
Port Group Monitor
Local Switching
Slow Drain Device Detection and Congestion Avoidance
Management Interfaces
VSAN Interfaces
Prerequisites for Interfaces
Guidelines and Limitations
Generation 1 Interface Configuration Guidelines
Private Loop Configuration Guidelines
VSAN Interface Configuration Guidelines
Default Settings
Configuring Interfaces
Configuring Fibre Channel Interfaces
Setting the Interface Administrative State
Configuring Interface Modes
Configuring System Default Port Mode F
Configuring ISL between Two Switches
Configuring 10-Gbps FC Mode
Configuring Port Administrative Speeds
Configuring Port Speed Group
Configuring the Interface Description
Specifying a Port Owner
Configuring Beacon Mode
Disabling Bit Error Threshold
Configuring Switch Port Attribute Default Values
Configuring TL Ports
Manually Inserting Entries into the ALPA Cache
Clearing the ALPA Cache
Configuring Port Guard
Configuring Port Monitor
Enabling Port Monitor
Configuring a Port Monitor Policy
Activating a Port Monitor Policy
Configuring a Port Monitor Port Guard
Configuring Port Group Monitor
Enabling Port Group Monitor
Configuring a Port Group Monitor Policy
Reverting to the Default Policy for a Specific Counter
Turning Off the Monitoring of Specific Counter
Activating a Port Group Monitor Policy
Configuring Management Interfaces
Creating VSAN Interfaces
Configuring Slow Drain Device Detection and Congestion Avoidance
Configuring Congestion Frame Timeout Value
Configuring Stuck Frame Timeout Value
Configuring No-Credit Timeout Value
Configuring Credit Loss Recovery Threshold and Action
Configuring Average Credit Nonavailable Duration Threshold and Action
Verifying Interfaces Configuration
Displaying Interface Information
Displaying TL Port Information
Displaying the ALPA Cache Contents
Displaying Port Monitor Status and Policies
Displaying Port Group Monitor Status and Policies
Displaying Management Interface Configuration
Displaying VSAN Interface Information
Configuring Interfaces
•Information About Interfaces
•Prerequisites for Interfaces
•Guidelines and Limitations
•Default Settings
•Configuring Interfaces
•Verifying Interfaces Configuration
Information About Interfaces
The main function of a switch is to relay frames from one data link to another. To relay the frames, the characteristics of the interfaces through which the frames are received and sent must be defined. The configured interfaces can be Fibre Channel interfaces, Gigabit Ethernet interfaces, the management interface (mgmt0), or VSAN interfaces.
This section includes the following topics:
•Interface Description
•Interface Modes
•Interface States
•Graceful Shutdown
•Port Administrative Speeds
•Frame Encapsulation
•Beacon LEDs
•Speed LEDs
•Bit Error Thresholds
•SFP Transmitter Types
•TL Ports
•TL Port ALPA Caches
•Port Guard
•Port Monitor
•Port Monitor Port Guard
•Port Group Monitor
•Local Switching
•Slow Drain Device Detection and Congestion Avoidance
•Management Interfaces
•VSAN Interfaces
Interface Description
For the Fibre Channel interfaces, you can configure the description parameter to provide a recognizable name for the interface. Using a unique name for each interface allows you to quickly identify the interface when you are looking at a listing of multiple interfaces. You can also use the description to identify the traffic or the use for that interface.
Interface Modes
Each physical Fibre Channel interface in a switch may operate in one of several port modes: E port, F port, FL port, TL port, TE port, SD port, ST port, and B port (see Figure 2-1). Besides these modes, each interface may be configured in auto or Fx port modes. These two modes determine the port type during interface initialization.
Figure 2-1 Cisco MDS 9000 Family Switch Port Modes
Note Interfaces are created in VSAN 1 by default. See the Cisco MDS 9000 Family NX-OS Fabric Configuration Guide.
Each interface has an associated administrative configuration and an operational status:
•The administrative configuration does not change unless you modify it. This configuration has various attributes that you can configure in administrative mode.
•The operational status represents the current status of a specified attribute like the interface speed. This status cannot be changed and is read-only. Some values may not be valid when the interface is down (for example, the operational speed).
Note When a module is removed and replaced with the same type of module, the configuration is retained. If a different type of module is inserted, then the original configuration is no longer retained.
Each interface is briefly described in the sections that follow.
E Port
In expansion port (E port) mode, an interface functions as a fabric expansion port. This port may be connected to another E port to create an Inter-Switch Link (ISL) between two switches. E ports carry frames between switches for configuration and fabric management. They serve as a conduit between switches for frames destined to remote N ports and NL ports. E ports support class 2, class 3, and class F service.
An E port connected to another switch may also be configured to form a PortChannel (see Chapter 6 "Configuring PortChannels").
Note We recommend that you configure E ports on 16-port modules. If you must configure an E port on a 32-port oversubscribed module, then you can only use the first port in a group of four ports (for example, ports 1 through 4, 5 through 8, and so forth). The other three ports cannot be used.
F Port
In fabric port (F port) mode, an interface functions as a fabric port. This port may be connected to a peripheral device (host or disk) operating as an N port. An F port can be attached to only one N port. F ports support class 2 and class 3 service.
FL Port
In fabric loop port (FL port) mode, an interface functions as a fabric loop port. This port may be connected to one or more NL ports (including FL ports in other switches) to form a public arbitrated loop. If more than one FL port is detected on the arbitrated loop during initialization, only one FL port becomes operational and the other FL ports enter nonparticipating mode. FL ports support class 2 and class 3 service.
Note FL port mode is not supported on 4-port 10-Gbps switching module interfaces.
NP Ports
An NP port is a port on a device that is in NPV mode and connected to the core switch via an F port. NP ports function like N ports except that in addition to providing N port operations, they also function as proxies for multiple, physical N ports.
For more details about NP ports and NPV, see Chapter 7 "Configuring N Port Virtualization."
TL Port
In translative loop port (TL port) mode, an interface functions as a translative loop port. It may be connected to one or more private loop devices (NL ports). TL ports are specific to Cisco MDS 9000 Family switches and have similar properties as FL ports. TL ports enable communication between a private loop device and one of the following devices:
•A device attached to any switch on the fabric
•A device on a public loop anywhere in the fabric
•A device on a different private loop anywhere in the fabric
•A device on the same private loop
TL ports support class 2 and class 3 services.
Private loop devices refer to legacy devices that reside on arbitrated loops. These devices are not aware of a switch fabric because they only communicate with devices on the same physical loop (see the "TL Port ALPA Caches" section).
Tip We recommend configuring devices attached to TL ports in zones that have up to 64 zone members.
Note TL port mode is not supported on Generation 2 switching module interfaces.
TE Port
In trunking E port (TE port) mode, an interface functions as a trunking expansion port. It may be connected to another TE port to create an extended ISL (EISL) between two switches. TE ports are specific to Cisco MDS 9000 Family switches. They expand the functionality of E ports to support the following:
•VSAN trunking
•Transport quality of service (QoS) parameters
•Fibre Channel trace (fctrace) feature
In TE port mode, all frames are transmitted in EISL frame format, which contains VSAN information. Interconnected switches use the VSAN ID to multiplex traffic from one or more VSANs across the same physical link. This feature is referred to as trunking in the Cisco MDS 9000 Family switches (see Chapter 5 "Configuring Trunking"). TE ports support class 2, class 3, and class F service.
TF Port
In trunking F port (TF port) mode, an interface functions as a trunking expansion port. It may be connected to another trunked N port (TN port) or trunked NP port (TNP port) to create a link between a core switch and an NPV switch or an HBA to carry tagged frames. TF ports are specific to Cisco MDS 9000 Family switches. They expand the functionality of F ports to support VSAN trunking.
In TF port mode, all frames are transmitted in EISL frame format, which contains VSAN information. Interconnected switches use the VSAN ID to multiplex traffic from one or more VSANs across the same physical link. This feature is referred to as trunking in the Cisco MDS 9000 Family (see Chapter 5 "Configuring Trunking"). TF ports support class 2, class 3, and class F service.
TNP Port
In trunking NP port (TNP port) mode, an interface functions as a trunking expansion port. It may be connected to a trunked F port (TF port) to create a link to a core NPIV switch from an NPV switch to carry tagged frames.
SD Port
In SPAN destination port (SD port) mode, an interface functions as a switched port analyzer (SPAN). The SPAN feature is specific to switches in the Cisco MDS 9000 Family. It monitors network traffic that passes though a Fibre Channel interface. This monitoring is done using a standard Fibre Channel analyzer (or a similar switch probe) that is attached to an SD port. SD ports do not receive frames, they only transmit a copy of the source traffic. The SPAN feature is nonintrusive and does not affect switching of network traffic for any SPAN source ports (see the Cisco MDS 9000 Family NX-OS System Management Configuration Guide).
ST Port
In the SPAN tunnel port (ST port) mode, an interface functions as an entry point port in the source switch for the RSPAN Fibre Channel tunnel. The ST port mode and the remote SPAN (RSPAN) feature are specific to switches in the Cisco MDS 9000 Family. When configured in ST port mode, the interface cannot be attached to any device, and thus cannot be used for normal Fibre Channel traffic (see the Cisco MDS 9000 Family NX-OS System Management Configuration Guide).
Note ST port mode is not supported on the Cisco MDS 9124 Fabric Switch, the Cisco Fabric Switch for HP c-Class BladeSystem, and the Cisco Fabric Switch for IBM BladeCenter.
Fx Port
Interfaces configured as Fx ports can operate in either F port or FL port mode. The Fx port mode is determined during interface initialization depending on the attached N port or NL port. This administrative configuration disallows interfaces to operate in any other mode—for example, preventing an interface to connect to another switch.
B Port
While E ports typically interconnect Fibre Channel switches, some SAN extender devices, such as the Cisco PA-FC-1G Fibre Channel port adapter, implement a bridge port (B port) model to connect geographically dispersed fabrics. This model uses B ports as described in the T11 Standard FC-BB-2.
If an FCIP peer is a SAN extender device that only supports Fibre Channel B ports, you need to enable the B port mode for the FCIP link. When a B port is enabled, the E port functionality is also enabled and they coexist. If the B port is disabled, the E port functionality remains enabled (see the Cisco MDS 9000 Family NX-OS IP Services Configuration Guide).
Auto Mode
Interfaces configured in auto mode can operate in one of the following modes: F port, FL port, E port, TE port, or TF port. The port mode is determined during interface initialization. For example, if the interface is connected to a node (host or disk), it operates in F port or FL port mode depending on the N port or NL port mode. If the interface is attached to a third-party switch, it operates in E port mode. If the interface is attached to another switch in the Cisco MDS 9000 Family, it may become operational in TE port mode (see Chapter 5 "Configuring Trunking").
TL ports and SD ports are not determined during initialization and are administratively configured.
Note Fibre Channel interfaces on Storage Services Modules (SSMs) cannot be configured in auto mode.
Interface States
The interface state depends on the administrative configuration of the interface and the dynamic state of the physical link.
Administrative States
The administrative state refers to the administrative configuration of the interface as described in Table 2-1.
Table 2-1 Administrative States
Administrative State
|
Description
|
Up
|
Interface is enabled.
|
Down
|
Interface is disabled. If you administratively disable an interface by shutting down that interface, the physical link layer state change is ignored.
|
Operational States
The operational state indicates the current operational state of the interface as described in Table 2-2.
Table 2-2 Operational States
Operational State
|
Description
|
Up
|
Interface is transmitting or receiving traffic as desired. To be in this state, an interface must be administratively up, the interface link layer state must be up, and the interface initialization must be completed.
|
Down
|
Interface cannot transmit or receive (data) traffic.
|
Trunking
|
Interface is operational in TE or TF mode.
|
Reason Codes
Reason codes are dependent on the operational state of the interface as described in Table 2-3.
Table 2-3 Reason Codes for Interface States
Administrative Configuration
|
Operational Status
|
Reason Code
|
Up
|
Up
|
None.
|
Down
|
Down
|
Administratively down—If you administratively configure an interface as down, you disable the interface. No traffic is received or transmitted.
|
Up
|
Down
|
See Table 2-4.
|
Note Only some of the reason codes are listed in Table 2-4.
If the administrative state is up and the operational state is down, the reason code differs based on the nonoperational reason code as described in Table 2-4.
Table 2-4 Reason Codes for Nonoperational States
Reason Code (long version)
|
Description
|
Applicable Modes
|
Link failure or not connected
|
The physical layer link is not operational.
|
All
|
SFP not present
|
The small form-factor pluggable (SFP) hardware is not plugged in.
|
Initializing
|
The physical layer link is operational and the protocol initialization is in progress.
|
Reconfigure fabric in progress
|
The fabric is currently being reconfigured.
|
Offline
|
The Cisco NX-OS software waits for the specified R_A_TOV time before retrying initialization.
|
Inactive
|
The interface VSAN is deleted or is in a suspended state.
To make the interface operational, assign that port to a configured and active VSAN.
|
Hardware failure
|
A hardware failure is detected.
|
Error disabled
|
Error conditions require administrative attention. Interfaces may be error-disabled for various reasons. For example:
•Configuration failure.
•Incompatible buffer-to-buffer credit configuration.
To make the interface operational, you must first fix the error conditions causing this state; and next, administratively shut down or enable the interface.
|
FC redirect failure
|
A port is isolated because a Fibre Channel redirect is unable to program routes.
|
No port activation license available
|
A port is not active because it does not have a port license.
|
SDM failure
|
A port is isolated because SDM is unable to program routes.
|
Isolation due to ELP failure
|
The port negotiation failed.
|
Only E ports and TE ports
|
Isolation due to ESC failure
|
The port negotiation failed.
|
Isolation due to domain overlap
|
The Fibre Channel domains (fcdomain) overlap.
|
Isolation due to domain ID assignment failure
|
The assigned domain ID is not valid.
|
Isolation due to the other side of the link E port isolated
|
The E port at the other end of the link is isolated.
|
Isolation due to invalid fabric reconfiguration
|
The port is isolated due to fabric reconfiguration.
|
Isolation due to domain manager disabled
|
The fcdomain feature is disabled.
|
Isolation due to zone merge failure
|
The zone merge operation failed.
|
Isolation due to VSAN mismatch
|
The VSANs at both ends of an ISL are different.
|
Nonparticipating
|
FL ports cannot participate in loop operations. It may happen if more than one FL port exists in the same loop, in which case all but one FL port in that loop automatically enters nonparticipating mode.
|
Only FL ports and TL ports
|
PortChannel administratively down
|
The interfaces belonging to the PortChannel are down.
|
Only PortChannel interfaces
|
Suspended due to incompatible speed
|
The interfaces belonging to the PortChannel have incompatible speeds.
|
Suspended due to incompatible mode
|
The interfaces belonging to the PortChannel have incompatible modes.
|
Suspended due to incompatible remote switch WWN
|
An improper connection is detected. All interfaces in a PortChannel must be connected to the same pair of switches.
|
Graceful Shutdown
Interfaces on a port are shut down by default (unless you modified the initial configuration).
The Cisco NX-OS software implicitly performs a graceful shutdown in response to either of the following actions for interfaces operating in the E port mode:
•If you shut down an interface.
•If a Cisco NX-OS software application executes a port shutdown as part of its function.
A graceful shutdown ensures that no frames are lost when the interface is shutting down. When a shutdown is triggered either by you or the Cisco NX-OS software, the switches connected to the shutdown link coordinate with each other to ensure that all frames in the ports are safely sent through the link before shutting down. This enhancement reduces the chance of frame loss.
A graceful shutdown is not possible in the following situations:
•If you physically remove the port from the switch.
•If in-order delivery (IOD) is enabled (for information about IOD, refer to the Cisco MDS 9000 Family NX-OS Fabric Configuration Guide).
•If the Min_LS_interval interval is higher than 10 seconds. For information about FSPF global configuration, refer to the Cisco MDS 9000 Family NX-OS Fabric Configuration Guide.
Note This feature is only triggered if both switches at either end of this E port interface are MDS switches and are running Cisco SAN-OS Release 2.0(1b) or later, or MDS NX-OS Release 4.1(1a) or later.
Port Administrative Speeds
By default, the port administrative speed for an interface is automatically calculated by the switch.
For internal ports on the Cisco Fabric Switch for HP c_Class BladeSystem and Cisco Fabric Switch for IBM BladeCenter, a port speed of 1 Gbps is not supported. Auto-negotiation is supported between 2 Gbps and 4 Gbps only. Also, if the BladeCenter is a T chassis, then port speeds are fixed at 2 Gbps and auto-negotiation is not enabled.
Autosensing
Autosensing speed is enabled on all 4-Gbps and 8-Gbps switching module interfaces by default. This configuration enables the interfaces to operate at speeds of 1 Gbps, 2 Gbps, or 4 Gbps on the 4-Gbps switching modules, and 8 Gbps on the 8-Gbps switching modules. When autosensing is enabled for an interface operating in dedicated rate mode, 4 Gbps of bandwidth is reserved, even if the port negotiates at an operating speed of 1 Gbps or 2 Gbps.
To avoid wasting unused bandwidth on 48-port and 24-port 4-Gbps and 8-Gbps Fibre Channel switching modules, you can specify that only 2 Gbps of required bandwidth be reserved, not the default of 4 Gbps or 8 Gbps. This feature shares the unused bandwidth within the port group provided that it does not exceed the rate limit configuration for the port. You can also use this feature for shared rate ports that are configured for autosensing.
Tip When migrating a host that supports up to 2-Gbps traffic (that is, not 4 Gbps with autosensing capabilities) to the 4-Gbps switching modules, use autosensing with a maximum bandwidth of 2 Gbps. When migrating a host that supports up to 4-Gbps traffic (that is, not 8 Gbps with autosensing capabilities) to the 8-Gbps switching modules, use autosensing with a maximum bandwidth of 4 Gbps.
Frame Encapsulation
The switchport encap eisl command only applies to SD port interfaces. This command determines the frame format for all frames transmitted by the interface in SD port mode. If the encapsulation is set to EISL, all outgoing frames are transmitted in the EISL frame format, regardless of the SPAN sources.
The switchport encap eisl command is disabled by default. If you enable encapsulation, all outgoing frames are encapsulated, and you will see a new line (Encapsulation is eisl) in the show interface SD_port_interface command output. See the Cisco MDS 9000 Family NX-OS System Management Configuration Guide.
You can set the frame format to EISL for all frames transmitted by the interface in SD port mode. If you sent the frame encapsulation to EISL, all outgoing frames are transmitted in the EISL frame format, regardless of the SPAN sources. See the Cisco MDS 9000 Family NX-OS System Management Configuration Guide.
Beacon LEDs
Figure 2-2 displays the status, link, and speed LEDs in a 16-port switching module.
Figure 2-2 Cisco MDS 9000 Family Switch Interface Modes
1
|
Status LED1
|
3
|
Link LEDs1 and speed LEDs2
|
2
|
1/2-Gbps Fibre Channel port group3
|
4
|
Asset tag4
|
Speed LEDs
Each port has one link LED on the left and one speed LED on the right.
The speed LED displays the speed of the port interface:
•Off—The interface attached to that port is functioning at 1000 Mbps.
•On (solid green)—The interface attached to that port is functioning at 2000 Mbps (for 2 Gbps interfaces).
The speed LED also displays if the beacon mode is enabled or disabled:
•Off or solid green—Beacon mode is disabled.
•Flashing green—The beacon mode is enabled. The LED flashes at one-second intervals.
Note Generation 2, Generation 3, and Generation 4 modules and fabric switches do not have speed LEDs.
Bit Error Thresholds
The bit error rate threshold is used by the switch to detect an increased error rate before performance degradation seriously affects traffic.
The bit errors can occur for the following reasons:
•Faulty or bad cable.
•Faulty or bad GBIC or SFP.
•GBIC or SFP is specified to operate at 1 Gbps but is used at 2 Gbps.
•GBIC or SFP is specified to operate at 2 Gbps but is used at 4 Gbps.
•Short haul cable is used for long haul or long haul cable is used for short haul.
•Momentary sync loss.
•Loose cable connection at one or both ends.
•Improper GBIC or SFP connection at one or both ends.
A bit error rate threshold is detected when 15 error bursts occur in a 5-minute period. By default, the switch disables the interface when the threshold is reached. You can enter a shutdown and no shutdown command sequence to re-enable the interface.
You can configure the switch to not disable an interface when the threshold is crossed. By default, the threshold disables the interface.
SFP Transmitter Types
The small form-factor pluggable (SFP) hardware transmitters are identified by their acronyms when displayed. Table 2-5 defines the acronyms used for SFPs.
The small form-factor pluggable (SFP) hardware transmitters are identified by their acronyms when displayed in the show interface brief command. If the related SFP has a Cisco-assigned extended ID, then the show interface and show interface brief commands display the ID instead of the transmitter type. The show interface transceiver command and the show interface fc slot/port transceiver command display both values for Cisco-supported SFPs. Table 2-5 defines the acronyms used in the command output (see the "Displaying Interface Information" section).
Table 2-5 SFP Transmitter Acronym Definitions
Definition
|
Acronym
|
Standard transmitters defined in the GBIC specifications
|
short wave laser
|
swl
|
long wave laser
|
lwl
|
long wave laser cost reduced
|
lwcr
|
electrical
|
elec
|
Extended transmitters assigned to Cisco-supported SFPs
|
CWDM-1470
|
c1470
|
CWDM-1490
|
c1490
|
CWDM-1510
|
c1510
|
CWDM-1530
|
c1530
|
CWDM-1550
|
c1550
|
CWDM-1570
|
c1570
|
CWDM-1590
|
c1590
|
CWDM-1610
|
c1610
|
TL Ports
Private loop devices refer to legacy devices that reside on arbitrated loops. These devices are not aware of a switch fabric because they only communicate with devices on the same physical loop. The legacy devices are used in Fibre Channel networks, and devices outside the loop may need to communicate with them. The communication functionality is provided through TL ports. See the "Interface Modes" section.
TL port mode is not supported on the following hardware:
•Generation 2 switching module interfaces
•Cisco MDS 9124 Fabric Switch
•Cisco Fabric Switch for HP c-Class BladeSystem
•Cisco Fabric Switch for IBM BladeCenter
Table 2-6 lists the TL port translations supported in Cisco MDS 9000 Family switches.
Table 2-6 Supported TL Port Translations
Translation from
|
Translation to
|
Example
|
Private initiator
|
Private target
|
From I1 to T1 or vice versa
|
Private initiator
|
Public target — N port
|
From I1 to T2 or vice versa
|
Private initiator
|
Public target — NL port
|
From I4 to T3 or vice versa
|
Public initiator — N port
|
Private target
|
From I2 to T1 or vice versa
|
Public initiator — NL port
|
Private target
|
From I3 to T1 or vice versa
|
Figure 2-3 shows examples of TL port translation support.
Figure 2-3 TL Port Translation Support Examples
TL Port ALPA Caches
Although TL ports cannot be automatically configured, you can manually configure entries in arbitrated loop physical address (ALPA) caches. Generally, ALPA cache entries are automatically populated when an ALPA is assigned to a device. Each device is identified by its port world wide name (pWWN). When a device is allocated an ALPA, an entry for that device is automatically created in the ALPA cache.
A cache contains entries for recently allocated ALPA values. These caches are maintained on various TL ports. If a device already has an ALPA, the Cisco NX-OS software attempts to allocate the same ALPA to the device each time. The ALPA cache is maintained in persistent storage and saves information across switch reboots. The maximum cache size is 1000 entries. If the cache is full, and a new ALPA is allocated, the Cisco NX-OS software discards an inactive cache entry (if available) to make space for the new entry. See the "TL Port" section for more information on TL ports.
Port Guard
The port guard feature is intended for use in environments where the system and application environment does not adapt quickly and efficiently to a port going down and back up, or to a port rapidly cycling up and down, which can happen in some failure modes. For example, if a system takes five seconds to stabilize after a port goes down, but the port is going up and down once a second, a more severe failure in the fabric might occur.
The port guard feature gives the SAN administrator the ability to prevent this issue from occurring in environments that are vulnerable to these problems. The port can be configured to stay down after the first failure or after a specified number of failures in a specified time period. This allows the SAN administrator to intervene and control the recovery, avoiding any problems caused by the cycling.
Using the port guard feature, you can restrict the number of error reports and bring a malfunctioning port to down state dynamically. A port can be configured to go into error-disabled state for specific types of failures.
A general link failure caused by link-down is the superset of all other causes. The sum of the number of all other causes equals to the number of link-down link failures. This means a port is brought to down state when it reaches the maximum number of allowed link failures or the number of specific causes.
The causes of link failure can be any of the following:
•ESP trustsec-violation
•Bit-errors
•Signal loss
•Sync loss
•Link reset
•Credit loss
•Additional causes might be the following:
–Not operational (NOS).
–Too many interrupts.
–Cable is disconnected.
–Hardware recoverable errors.
–The connected device rebooted (F ports only).
–The connected linecard rebooted (ISL only).
Port Monitor
Port monitor helps to monitor the performance and the status of ports and generate alerts when problems occur. You can configure the thresholds for various counters and trigger an event when the values cross the threshold settings.
The default port monitor policy has the following threshold values:
Counter
|
Threshold Type
|
Interval (Seconds)
|
% Rising Threshold
|
Event
|
% Falling Threshold
|
Event
|
Link Loss
|
Delta
|
60
|
5
|
4
|
1
|
4
|
Sync Loss
|
Delta
|
60
|
5
|
4
|
1
|
4
|
Protocol Error
|
Delta
|
60
|
1
|
4
|
0
|
4
|
Signal Loss
|
Delta
|
60
|
5
|
4
|
1
|
4
|
Invalid Words
|
Delta
|
60
|
1
|
4
|
0
|
4
|
Invalid CRCs
|
Delta
|
60
|
5
|
4
|
1
|
4
|
RX Performance
|
Delta
|
60
|
2147483648
|
4
|
524288000
|
4
|
TX Performance
|
Delta
|
60
|
2147483648
|
4
|
524288000
|
4
|
Port Monitor Port Guard
Port monitor port guard is a feature that disables or shuts down a port when an event occurs. Depending on the configuration, when an event occurs the port is either error-disabled or flapped.
Port monitor port guard is a different or separate feature that functions based on the configuration of the errordisable command.
Port Group Monitor
Each line card or module has a predefined set of ports which share the same backplane bandwidth called port groups. While oversubscription is a feature, the port group monitor feature helps to monitor the spine bandwidth utilization. An alarm syslog is generated so that you can provision the ports across port groups evenly to manage the oversubscription better.
When the port group monitor feature is enabled and a policy consisting of polling interval in seconds, and the raising and falling thresholds in percentage are specified, port group monitor generates a syslog if a port group traffic goes above the specified percentage of the maximum supported bandwidth for that port group (for rx and for tx) and another syslog if the value falls below the specified threshold.
The default port group policy has the following threshold values:
Counter
|
Threshold Type
|
Interval (Seconds)
|
% Rising Threshold
|
% Falling Threshold
|
RX Performance
|
Delta
|
60
|
80
|
20
|
TX Performance
|
Delta
|
60
|
80
|
20
|
Local Switching
Local switching can be enabled in Generation 4 modules, which allows traffic to be switched directly with a local crossbar when the traffic is directed from one port to another on the same line card. By using local switching, an extra switching step is avoided, which decreases the latency.
When using local switching, note the following guidelines:
•All ports need to be in shared mode, which usually is the default state. To place a port in shared mode, enter the switchport ratemode shared command.
•E ports are not allowed in the module because they must be in dedicated mode.
Note Local Switching is not supported on MDS 9710.
Slow Drain Device Detection and Congestion Avoidance
All data traffic between end devices in a SAN fabric is carried by Fibre Channel Class 3. In some cases, the traffic is carried by Class 2 services that use link-level, per-hop-based, and buffer-to-buffer flow control. These classes of service do not support end-to-end flow control. When there are slow devices attached to the fabric, the end devices do not accept the frames at the configured or negotiated rate. The slow devices lead to ISL credit shortage in the traffic destined for these devices and they congest the links. The credit shortage affects the unrelated flows in the fabric that use the same ISL link even though destination devices do not experience slow drain.
This feature provides various enhancements to detect slow drain devices that are causing congestion in the network and also provides a congestion avoidance function.
This feature is focused mainly on the edge ports that are connected to slow drain devices. The goal is to avoid or minimize the frames being stuck in the edge ports due to slow drain devices that are causing ISL blockage. To avoid or minimize the stuck condition, configure lesser frame timeout for the ports. No-credit timeout drops all packets once the slow drain is detected using the configured thresholds. The lesser frame timeout value helps to alleviate the slow drain condition that affects the fabric by dropping the packets on the edge ports sooner than the time they actually get timed out (500 ms). This function frees the buffer space in ISL, which can be used by other unrelated flows that do not experience slow drain condition.
Note This feature is used mainly for edge ports that are connected to slow edge devices. Even though this feature can be applied to ISLs as well, we recommend that you apply this feature only for edge F ports and retain the default configuration for ISLs as E and TE ports. This feature is not supported on Generation 1 modules.
Management Interfaces
You can remotely configure the switch through the management interface (mgmt0). To configure a connection on the mgmt0 interface, you must configure either the IP version 4 (IPv4) parameters (IP address, subnet mask, and default gateway) or the IP version 6 (IPv6) parameters so that the switch is reachable.
Before you begin to configure the management interface manually, obtain the switch's IPv4 address and subnet mask, or the IPv6 address.
The management port (mgmt0) is autosensing and operates in full-duplex mode at a speed of 10/100/1000 Mbps. Autosensing supports both the speed and the duplex mode. On a Supervisor-1 module, the default speed is 100 Mbps and the default duplex mode is auto. On a Supervisor-2 module, the default speed is auto and the default duplex mode is auto.
Note You need to explicitly configure a default gateway to connect to the switch and send IP packets or add a route for each subnet.
VSAN Interfaces
VSANs apply to Fibre Channel fabrics and enable you to configure multiple isolated SAN topologies within the same physical infrastructure. You can create an IP interface on top of a VSAN and then use this interface to send frames to this VSAN. To use this feature, you must configure the IP address for this VSAN. VSAN interfaces cannot be created for nonexisting VSANs.
Prerequisites for Interfaces
Before you begin configuring the interfaces, ensure that the modules in the chassis are functioning as designed. To verify the status of a module at any time, enter the show module command in EXEC mode. For information about verifying the module status, refer to the Cisco NX-OS Fundamentals Configuration Guide.
Guidelines and Limitations
This section includes the following topics:
•Generation 1 Interface Configuration Guidelines
•Private Loop Configuration Guidelines
•VSAN Interface Configuration Guidelines
Generation 1 Interface Configuration Guidelines
The Generation 1 interfaces configuration guidelines apply to the following hardware:
•The 32-port, 2-Gbps or 1-Gbps switching module interfaces
•The Cisco MDS 9140 and 9120 switch interfaces
Note Due to the hardware design of the MDS 9134 switch, we do not support interface out-of-service action on either of its two 10-Gigabit ports. This is because no internal port hardware resource is released when an out-of-service action is performed on these 10-Gigabit ports.
When configuring these host-optimized ports, the following port mode guidelines apply:
•You can configure only the first port in each 4-port group (for example, the first port in ports 1-4, the fifth port in ports 5-8, and so on) as an E port. If the first port in the group is configured as an E port, the other three ports in each group (ports 2-4, 6-8, and so on) are not usable and remain shutdown.
•If you execute the write erase command on a 32-port switching module, and then copy a saved configuration to the switch from a text file that contains the no system default switchport shutdown command, you need to copy the text file to the switch again for the E ports to come up without manual configuration.
•If any of the other three ports are enabled, you cannot configure the first port as an E port. The other three ports continue to remain enabled.
•The auto mode is not allowed in a 32-port switching module or the host-optimized ports in the Cisco 9100 Series (16 host-optimized ports in the Cisco MDS 9120 switch and 32 host-optimized ports in the Cisco MDS 9140 switch).
•The default port mode is Fx (Fx negotiates to F or FL) for 32-port switching modules.
•The 32-port switching module does not support FICON.
Note We recommend that you configure your E ports on a 16-port switching module. If you must configure an E port on a 32-port host-optimized switching module, the other three ports in that 4-port group cannot be used.
Note In the Cisco MDS 9100 Series, the groups of ports that are located on the left and outlined in white are full line rate. The other ports are host-optimized. Each group of 4 host-optimized ports have the same features as for the 32-port switching module.
Private Loop Configuration Guidelines
Follow these guidelines when configuring private loops:
•A maximum of 64 fabric devices can be proxy to a private loop.
•Fabric devices must be in the same zone as private loop devices to be proxy to the private loop.
•Each private device on a TL port may be included in a different zone.
•All devices on the loop are treated as private loops. You cannot mix private and public devices on the loop if the configured port mode is TL.
•The only FC4-type supported by TL ports is SCSI (FCP).
•Communication between a private initiator to a private target on the same private loop does not invoke TL port services.
VSAN Interface Configuration Guidelines
Follow these guidelines when creating or deleting VSAN interfaces:
•Create a VSAN before creating the interface for that VSAN. If a VSAN does not exist, the interface cannot be created.
•Create the interface VSAN—it is not created automatically.
•If you delete the VSAN, the attached interface is automatically deleted.
•Configure each interface only in one VSAN.
Tip After configuring the VSAN interface, you can configure an IP address or Virtual Router Redundancy Protocol (VRRP) feature. See the Cisco MDS 9000 Family NX-OS IP Services Configuration Guide.
Default Settings
Table 2-7 lists the default settings for interface parameters.
Table 2-7 Default Interface Parameters
Parameters
|
Default
|
Interface mode
|
Auto
|
Interface speed
|
Auto
|
Administrative state
|
Shutdown (unless changed during initial setup)
|
Trunk mode
|
On (unless changed during initial setup) on non-NPV and NPIV core switches. Off on NPV switches.
|
Trunk-allowed VSANs or VF-IDs
|
1 to 4093
|
Interface VSAN
|
Default VSAN (1)
|
Beacon mode
|
Off (disabled)
|
EISL encapsulation
|
Disabled
|
Data field size
|
2112 bytes
|
Configuring Interfaces
This section includes the following topics:
•Configuring Fibre Channel Interfaces
•Setting the Interface Administrative State
•Configuring Interface Modes
•Configuring System Default Port Mode F
•Configuring Port Administrative Speeds
•Configuring Port Speed Group
•Configuring the Interface Description
•Specifying a Port Owner
•Configuring Beacon Mode
•Disabling Bit Error Threshold
•Configuring Switch Port Attribute Default Values
•Configuring TL Ports
•Manually Inserting Entries into the ALPA Cache
•Clearing the ALPA Cache
•Configuring Port Guard
•Configuring Port Monitor
•Configuring Port Group Monitor
•Configuring Management Interfaces
•Creating VSAN Interfaces
•Configuring Slow Drain Device Detection and Congestion Avoidance
For more information on configuring mgmt0 interfaces, refer to the Cisco MDS 9000 Family NX-OS Fundamentals Configuration Guide and Cisco MDS 9000 Family NX-OS IP Services Configuration Guide.
For more information on configuring Gigabit Ethernet interfaces, see the Cisco MDS 9000 Family NX-OS IP Services Configuration Guide.
Configuring Fibre Channel Interfaces
Detailed Steps
To configure a Fibre Channel interface, follow these steps:
|
Command
|
Purpose
|
Step 1
|
switch# config t
|
Enters configuration mode.
|
Step 2
|
switch(config)# interface fc1/1
switch(config-if)#
|
Selects a Fibre Channel interface and enters interface configuration submode.
Note When a Fibre Channel interface is configured, it is automatically assigned a unique world wide name (WWN). If the interface's operational state is up, it is also assigned a Fibre Channel ID (FC ID).
|
To configure a range of interfaces, follow these steps:
|
Command
|
Purpose
|
Step 1
|
switch# config t
|
Enters configuration mode.
|
Step 2
|
switch(config)# interface fc1/1 - 4 , fc2/1 - 3
switch(config-if)#
|
Selects the range of Fibre Channel interfaces and enters interface configuration submode3.
Note In this command, provide a space before and after the comma.
|
For the Cisco Fabric Switch for HP c-Class BladeSystem and the Cisco Fabric Switch for IBM BladeCenter, you can configure a range of interfaces among internal ports or external ports, but you cannot mix both interface types within the same range. For example, "bay 1-10, bay 12" or "ext 0, ext 15-18" are valid ranges, but "bay 1-5, ext 15-17" is not.
Setting the Interface Administrative State
Detailed Steps
To gracefully shut down an interface, follow these steps:
|
Command
|
Purpose
|
Step 1
|
switch# config t
|
Enters configuration mode.
|
Step 2
|
switch(config)# interface fc1/1
|
Selects a Fibre Channel interface and enters interface configuration submode.
|
Step 3
|
switch(config-if)# shutdown
|
Gracefully shuts down the interface and administratively disables traffic flow (default).
|
To enable traffic flow, follow these steps:
|
Command
|
Purpose
|
Step 1
|
switch# config t
|
Enters configuration mode.
|
Step 2
|
switch(config)# interface fc1/1
|
Selects a Fibre Channel interface and enters interface configuration submode.
|
Step 3
|
switch(config-if)# no shutdown
|
Enables traffic flow to administratively allow traffic when the no prefix is used (provided the operational state is up).
|
Configuring Interface Modes
Detailed Steps
To configure the interface mode, follow these steps:
|
Command
|
Purpose
|
Step 1
|
switch# config t
|
Enters configuration mode.
|
Step 2
|
switch(config)# interface fc1/1
switch(config-if)#
|
Selects a Fibre Channel interface and enters interface configuration submode.
|
Step 3
|
switch(config-if)# switchport mode F
switch(config-if)#
|
Configures the administrative mode of the port. You can set the operational state to auto, E, F, FL, Fx, TL, NP, or SD port mode.
Note Fx ports refers to an F port or an FL port (host connection only), but not E ports.
|
switch(config-if)# switchport mode auto
switch(config-if)#
|
Configures the interface mode to auto-negotiate an E, F, FL, or TE port mode (not TL or SD port modes) of operation.
Note TL ports and SD ports cannot be configured automatically. They must be administratively configured.
Note You cannot configure Fibre Channel interfaces on SSMs in auto mode.
|
Configuring System Default Port Mode F
The system default switchport mode F command sets the administrative mode of all Fibre Channel ports to mode F, while avoiding traffic disruption caused by the formation of unwanted Inter-Switch Links (ISLs). This command is part of the setup utility that runs during bootup after a write erase or reload. It can also be executed from the command line in configuration mode. This command changes the configuration of the following ports to administrative mode F:
•All ports that are down and that are not out-of-service.
•All F ports that are up, whose operational mode is F, and whose administrative mode is not F.
This command does not affect the configuration of the following ports:
•All user-configured ports, even if they are down.
•All non-F ports that are up; however, if non-F ports are down, this command changes the administrative mode of those ports.
Restrictions
•To ensure that ports that are part of ISLs do not get changed to port mode F, configure the ports in port mode E, rather than in Auto mode.
•When the command is executed from the command line, switch operation remains graceful. No ports are flapped.
Detailed Steps
To set the administrative mode of Fibre Channel ports to mode F in the CLI, follow these steps:
|
Command
|
Purpose
|
Step 1
|
switch# config t
|
Enters configuration mode.
|
Step 2
|
switch(config)# system default
switchport mode F
|
Sets the administrative mode of Fibre Channel ports to mode F (if applicable).
|
|
switch(config)# no system default
switchport mode F
|
Sets the administrative mode of Fibre Channel ports to the default (unless user configured).
|
Note For detailed information about the switch setup utility, see the Cisco MDS 9000 Family NX-OS Fundamentals Configuration Guide.
Example 2-1 shows the command in the setup utility, and Example 2-2 shows the command from the command line.
Example 2-1 Setup Utility
Configure default switchport mode F (yes/no) [n]: y
Example 2-2 Command Line
switch(config)# system default switchport mode F
Configuring ISL between Two Switches
Note Ensure the FC cable is connected between the ports and do a no-shut on each port.
E-port mode is used when the port functions as one end of an Inter-Switch Link (ISL) setting. When you set the port mode to E, you restrict the port coming up as an E port (trunking or non-trunking, depending on the trunking port mode).
switch# conf t --------> Enter configuration commands, one per line. End with CNTL/Z.
switch(config)# interface fc <Slot No/Port No>
switch(config-if)# switchport mode E
Ensure you follow this on both the switches between which you are attempting to bring up the ISL link.
Configuring 10-Gbps FC Mode
The 48-port 8-Gbps Advanced Fibre Channel module (DS-X9248-256K9) and the 32-port 8-Gbps Advanced Fibre Channel module (DS-X9232-256K9)can switch between two speed modes—the 1-, 2-, 4-, 8-Gbps or 10-Gbps. By default, the modules are online in the 1-, 2-, 4-, and 8-Gbps modes when they are loaded for the first time. There are two ways to change the ports to the 10-Gbps speed mode:
•Using the 10G-speed mode command, which is the recommended method.
•Using the generic speed configuration switchport speed command which has certain constraints.
The following conditions apply when the ports in the module can be configured to 10-Gbps speed mode:
•The ports in the module can be configured to 10-Gbps speed only when the DS-13SLT-FAB3 module bandwidth is 256-G. Any other combination of fabric modules will not let the ports come up in 10-Gbps.
•When in 10-Gbps mode, the ports in the module that are not 10-Gbps capable are disabled and will be in out-of-service state.
•The ports function only in full rate mode. They cannot be moved to shared rate mode.
•The ports cannot be configured in any other speed.
•Ports that are capable of 10-Gbps that are disabled or out-of-service cannot be put back in service using the no out-of-service command. To put these ports back in service, all ports in the module first have to be moved to the out-of-service state. Then they can be brought back to the in service state.
•Local switching must be disabled, otherwise, ports cannot be configured in dedicated mode.
Only certain ports on the 48-port and 32-port 8-Gbps Advanced Fibre Channel modules are 10-Gbps capable. When running in 10-Gbps mode, the non-10-Gbps ports cannot be operational. They have to be either in shut state or out-of-service state.
Detailed Steps
To configure the interface mode, follow these steps:
|
Command
|
Purpose
|
Step 1
|
switch# config t
|
Enters configuration mode.
|
Step 2
|
switch(config)# interface fc1/1-12
switch(config-if)#
|
Selects a Fibre Channel interface and enters interface configuration submode.
Note Ensure that one full ASIC range of ports are selected before executing this command. For example, /1-12 for a 48-port module or fcY/1-8 for a 32-port module.
The first ASIC on the 48-port module has ports fc1/1-12.
|
Step 3
|
switch(config-if)# 10G-speed-mode
|
Configures all the ports (fc1 to 12) to out-of-service state.
Moves the ports that are capable of a10-Gbps configuration (fc1/4-8 and fc1/10) to in-service state.
Sets the speed on ports fc1/4-8 and fc1/10 to 10-Gbps.
Sets port modes on these ports to dedicated.
Performs a no shut on these ports.
|
switch(config-if)# no 10G-speed-mode
|
Reverts the settings and puts all the ports (fc1 to 12) in out-of-service state and moves them to in-service state.
|
Configuring Port Administrative Speeds
Restrictions
•Changing the port administrative speed is a disruptive operation.
Detailed Steps
To configure the port speed of the interface, follow these steps:
|
Command
|
Purpose
|
Step 1
|
switch# config t
|
Enters configuration mode.
|
Step 2
|
switch(config)# interface fc 1/1
|
Selects the fc interface and enters interface configuration mode.
|
Step 3
|
switch(config-if)# switchport speed 1000
|
Configures the port speed of the interface to 1000 Mbps.
The number indicates the speed in megabits per second (Mbps).
|
switch(config-if)# switchport speed
10000
|
Configures the port speed of the interface to 10000 Mbps (for 10-Gbps).
Note All the 10-Gbps capable interfaces, except the interface that is being configured, must be in the out-of-service state. At least one other 10-Gbps capable interface must be in the in-service state.
|
switch(config-if)# no switchport speed
|
Reverts the factory default (auto) administrative speed of the interface.
|
Configuring Port Speed Group
Detailed Steps
To configure the port speed group of the interface, follow these steps:
|
Command
|
Purpose
|
Step 1
|
switch# config t
|
Enters configuration mode.
|
Step 2
|
switch(config)# interface fc 1/1
|
Selects the fc interface and enters interface configuration mode.
|
Step 3
|
switch(config-if)# speed group 10g
|
Configures the port speed group to 10 Gbps.
Note The preferred way of changing the speed group is the 10g-speed-mode command.
|
switch(config-if)# no speed group 10g
|
Unsets the port speed group and reverts to the factory default (auto) administrative speed group of the interface.
|
Configuring the Interface Description
The interface description can be any alphanumeric string.
Detailed Steps
To configure a description for an interface, follow these steps:
|
Command
|
Purpose
|
Step 1
|
switch# config t
|
Enters configuration mode.
|
Step 2
|
switch(config)# interface fc1/1
switch(config-if)#
|
Selects a Fibre Channel interface and enters interface configuration submode.
|
Step 3
|
switch(config-if)# switchport description cisco-HBA2
|
Configures the description of the interface. The string can be up to 80 characters long.
|
switch(config-if)# no switchport description
|
Clears the description of the interface.
|
Specifying a Port Owner
Using the port owner feature, you can specify the owner of a port and the purpose for which a port is used so that the other administrators are informed.
Note The port guard and port owner features are available for all ports regardless of the operational mode.
Detailed Steps
To specify or remove the port owner, follow these steps:
|
Command
|
Purpose
|
Step 1
|
switch# config t
|
Enters configuration mode.
|
Step 2
|
switch(config)# interface fc1/1
|
Selects the port interface.
|
Step 3
|
switch(config)# switchport owner description
|
Specifies the owner of the switch port. The description can include name of the owner and the purpose for which the port is used. The description can be up to 80 characters long.
|
switch(config)# no switchport owner
|
Removes (default) the port owner description.
|
To display the owner description specified for a port, use the following commands:
switch# show running interface fc module-number/interface-number
switch# show port internal info interface fc module-number/interface-number
Configuring Beacon Mode
By default, the beacon mode is disabled on all switches. The beacon mode is indicated by a flashing green light that helps you identify the physical location of the specified interface. Configuring the beacon mode has no effect on the operation of the interface.
Detailed Steps
To enable beacon mode for a specified interface or range of interfaces, follow these steps:
|
Command
|
Purpose
|
Step 1
|
switch# config t
switch(config)#
|
Enters configuration mode.
|
Step 2
|
switch(config)# interface fc1/1
switch(config-if)#
|
Selects a Fibre Channel interface and enters interface configuration submode.
|
Step 3
|
switch(config-if)# switchport beacon
|
Enables the beacon mode for the interface.
|
switch(config-if)# no switchport beacon
|
Disables the beacon mode for the interface.
|
Troubleshooting Tips
•The flashing green light turns on automatically when an external loopback is detected that causes the interfaces to be isolated. The flashing green light overrides the beacon mode configuration. The state of the LED is restored to reflect the beacon mode configuration after the external loopback is removed.
Disabling Bit Error Threshold
Detailed Steps
To disable the bit error threshold for an interface, follow these steps:
|
Command
|
Purpose
|
Step 1
|
switch# config t
|
Enters configuration mode.
|
Step 2
|
switch(config)# interface fc1/1
switch(config-if)#
|
Selects a Fibre Channel interface and enters interface configuration submode.
|
Step 3
|
switch(config-if)# switchport ignore
bit-errors
|
Prevents the detection of bit error threshold events from disabling the interface.
|
switch(config-if)# no switchport ignore
bit-errors
|
Prevents the detection of bit error threshold events from enabling the interface.
|
Troubleshooting Tips
•Regardless of the setting of the switchport ignore bit-errors command, the switch generates a syslog message when bit-error threshold events are detected.
Configuring Switch Port Attribute Default Values
You can configure attribute default values for various switch port attributes. These attributes will be applied globally to all future switch port configurations, even if you do not individually specify them at that time.
Detailed Steps
To configure switch port attributes, follow these steps:
|
Command
|
Purpose
|
Step 1
|
|
Enters configuration mode.
|
Step 2
|
switch(config)# no system default
switchport shutdown
switch(config)#
|
Configures the default setting for administrative state of an interface as Up. (The factory default setting is Down).
Tip This command is applicable only to interfaces for which no user configuration exists for the administrative state.
|
switch(config)# system default
switchport shutdown
switch(config)#
|
Configures the default setting for administrative state of an interface as Down. This is the factory default setting.
Tip This command is applicable only to interfaces for which no user configuration exists for the administrative state.
|
switch(config)# system default
switchport trunk mode auto
switch(config)#
|
Configures the default setting for administrative trunk mode state of an interface as Auto.
Note The default setting is trunk mode on.
|
Configuring TL Ports
Private loops require setting the interface mode to TL.
Use the switchport mode command to configure a TL port. See the "Configuring Interface Modes" section.
Manually Inserting Entries into the ALPA Cache
Detailed Steps
To manually insert entries into the ALPA cache, follow these steps:
|
Command
|
Purpose
|
Step 1
|
switch# config t
|
Enters configuration mode.
|
Step 2
|
switch(config)# tlport alpa-cache interface
fc1/2 pwwn 22:00:00:20:37:46:09:bd alpa 0x02
|
Configures manual entries into the ALPA cache.
|
Step 3
|
switch(config)# tlport alpa-cache interface
fc1/3 pwwn 22:00:00:20:37:46:09:bd
|
Removes this entry from the ALPA cache.
|
Clearing the ALPA Cache
The clear tlport alpa-cache command clears the entire content of the ALPA cache.
Configuring Port Guard
Detailed Steps
To enable or disable the port guard for a port, follow these steps:
|
Command
|
Purpose
|
Step 1
|
switch# config t
|
Enters configuration mode.
|
Step 2
|
switch(config)# interface fc1/1
|
Selects the port interface.
|
Step 3
|
switch(config)# errdisable detect cause
link-down
|
Brings the port to down state if the link flaps once.
|
switch(config)# errdisable detect cause
link-down [num-times number duration
seconds]
|
Enables the port guard configuration for the interface. Brings the port to down state if the link flaps for the number of instances within the specified seconds.
|
switch(config)# no errdisable detect cause
link-down
|
Removes (default) the port guard configuration for the interface. The link resumes flapping and sending error reports normally.
|
Step 4
|
switch(config)# errdisable detect cause
{trustsec-violation | bit-errors |
credit-loss | link-reset | signal-loss |
sync-loss}
|
Brings the port to down state if the specified error occurs even once.
|
switch(config)# errdisable detect cause
{trustsec-violation | bit-errors |
credit-loss | link-reset | signal-loss |
sync-loss} [num-times number duration
seconds]
|
Brings the port to down state if the specified error occurs for the number of instances within the specified seconds.
|
switch(config)# no errdisable detect cause
{trustsec-violation | bit-errors |
credit-loss | link-reset | signal-loss |
sync-loss}
|
Removes (default) the port guard configuration for the interface. The link resumes flapping and sending error reports normally.
|
Examples
This example shows how to configure port guard to bring a port to down state if the link flaps 5 times within 120 seconds based on multiple causes:
Switch (config)# interface fc1/1
Switch (config-if)# errdisable detect cause link-down num-times 5 duration 120
Switch (config-if)# errdisable detect cause bit-errors num-times 5 duration 120
Switch (config-if)# errdisable detect cause credit-loss num-times 5 duration 120
The above example sets the configuration to the following status:
•The port will be error-disabled due to bit errors if the port suffers link failure due to bit errors 5 times in 120 seconds.
•The port will be error-disabled due to credit loss if the port suffers link failure due to credit loss 5 times in 120 seconds.
•The port will be error-disabled due to link down if the port suffers link failure due to bit errors 2 times and link-failure due to credit loss 3 times in 120 seconds.
This example shows the internal information about a port in down state because of TrustSec violation:
Switch# show port internal info interface fc8/3
fc8/3 is down (Error disabled - port down due to trustsec violation)
Hardware is Fibre Channel, SFP is short wave laser w/o OFC (SN)
Port WWN is 21:c3:00:0d:ec:10:57:80
Admin port mode is E, trunk mode is on
snmp link state traps are enabled
Receive data field Size is 2112
5 minutes input rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
5 minutes output rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
11274 frames input, 1050732 bytes
11242 frames output, 971900 bytes
11 input OLS, 34 LRR, 10 NOS, 0 loop inits
72 output OLS, 37 LRR, 2 NOS, 0 loop inits
Interface last changed at Sun Nov 27 07:34:05 1988
admin port-down trustsec-violation(3) num_times 0, duration = 0
state reason (Error disabled - port down due to trustsec violation)
Port guard trustsec violation is Enabled
errdisabled on trustsec violation TRUE, oper cnt = 1
port guard first trustsec violation Sun Nov 27 07:34:05 1988
Troubleshooting Tips
•Link down is the superset of all other causes. A port is brought to down state if the total number of other causes equals to the number of allowed link-down failures.
•Even if the link does not flap due to failure of the link, and port guard is not enabled, the port goes into a down state if too many invalid FLOGI requests are received from the same host. Use the shut and the no shut commands consecutively to bring up the link.
Configuring Port Monitor
This section includes the following topics:
•Enabling Port Monitor
•Configuring a Port Monitor Policy
•Activating a Port Monitor Policy
Enabling Port Monitor
Detailed Steps
To enable port monitor, follow these steps:
|
Command
|
Purpose
|
Step 1
|
switch# config t
|
Enters configuration mode.
|
Step 2
|
switch(config)# port-monitor enable
|
Enables (default) port monitoring.
|
switch(config)# no port-monitor enable
|
Disables port monitoring.
|
Configuring a Port Monitor Policy
Detailed Steps
To configure a port monitor policy, follow these steps:
|
Command
|
Purpose
|
Step 1
|
switch# config t
|
Enters configuration mode.
|
Step 2
|
switch(config)# port-monitor name policyname
|
Specifies the policy name and enters the port monitoring policy configuration mode.
|
switch(config)# no port-monitor name
policyname
|
Removes the policy.
|
switch# config t
|
Enters configuration mode.
|
Step 3
|
switch(config-port-monitor)# port-type
access-port
|
Applies the policy to the access ports.
|
switch(config-port-monitor)# port-type trunks
|
Applies the policy to the trunk ports.
|
switch(config-port-monitor)# port-type all
|
Applies the policy to all ports.
|
Step 4
|
switch(config-port-monitor)# counter
credit-loss-reco poll-interval seconds
percentage1 event event-id delta
rising-threshold percentage1 event event-id
|
Specifies the delta credit loss recovery counter, poll interval in seconds, the thresholds in percentage, and the event IDs of events.
|
Step 5
|
switch(config-port-monitor)# monitor counter
err-pkt-from-port1
switch(config-port-monitor)# counter
err-pkt-from-port1 poll-interval seconds
delta rising-threshold eventcount1 event
event-id falling-threshold2 eventcount2 event
event-id
|
Activates the err-pkt-from-port counter.
Specifies the delta err-pkt-from-port counter, poll interval in seconds, the thresholds in percentage, and the event IDs of events.
|
Step 6
|
switch(config-port-monitor)# monitor counter
err-pkt-from-xbar1
switch(config-port-monitor)# counter
err-pkt-from-xbar1 poll-interval seconds
delta rising-threshold eventcount1 event
event-id
|
Activates the err-pkt-from-xbar counter.
Specifies the delta err-pkt-from-xbar counter, poll interval in seconds, the thresholds in the count of error frame events, and the event IDs of events.
|
Step 7
|
switch(config-port-monitor)# monitor counter
err-pkt-to-xbar1
switch(config-port-monitor)# counter
err-pkt-to-xbar1 poll-interval seconds delta
rising-threshold eventcount1 event event-id
falling-threshold2 eventcount2 event event-id
|
Activates the err-pkt-to-xbar counter.
Specifies the delta err-pkt-to-xbar counter, poll interval in seconds, the thresholds in the count of error frame events, and the event IDs of events.
|
Step 8
|
switch(config-port-monitor)# counter
invalid-crc poll-interval seconds delta
rising-threshold percentage1 event event-id
falling-threshold2 percentage2 event event-id
|
Specifies the delta invalid CRC, poll interval in seconds, the thresholds in percentage, and the event IDs of events to be triggered.
|
Step 9
|
switch(config-port-monitor)# counter
invalid-words poll-interval seconds delta
rising-threshold percentage1 event event-id
falling-threshold2 percentage2 event event-id
|
Specifies the delta invalid words, poll interval in seconds, the thresholds in percentage, and the event IDs of events to be triggered.
|
Step 10
|
switch(config-port-monitor)# counter
link-loss poll-interval seconds delta
rising-threshold percentage1 event event-id
falling-threshold2 percentage2 event event-id
|
Specifies the delta link failure counter, poll interval in seconds, the thresholds in percentage, and the event IDs of events to be triggered.
|
Step 11
|
switch(config-port-monitor)# counter
protocol-error poll-interval seconds delta
rising-threshold percentage1 event event-id
falling-threshold2 percentage2 event event-id
|
Specifies the delta protocol error poll interval in seconds, the thresholds in percentage, and the event IDs of events to be triggered.
|
Step 12
|
switch(config-port-monitor)# counter
rx-performance poll-interval seconds delta
rising-threshold percentage1 event event-id
falling-threshold2 percentage2 event event-id
|
Specifies the delta Rx counter poll interval in seconds and thresholds in percentage.
|
Step 13
|
switch(config-port-monitor)# counter
signal-loss poll-interval seconds delta
rising-threshold percentage1 event event-id
falling-threshold2 percentage2 event event-id
|
Specifies the delta signal loss poll interval in seconds, the thresholds in percentage, and the event IDs of events to be triggered.
|
Step 14
|
switch(config-port-monitor)# counter
state-change poll-interval seconds delta
rising-threshold percentage1 event event-id
falling-threshold2 percentage2 event event-id
|
Specifies the delta state change poll interval in seconds, the thresholds in percentage, and the event IDs of events to be triggered.
|
Step 15
|
switch(config-port-monitor)# counter
sync-loss poll-interval seconds delta
rising-threshold percentage1 event event-id
falling-threshold2 percentage2 event event-id
|
Specifies the delta sync loss poll interval in seconds, the thresholds in percentage, and the event IDs of events to be triggered.
|
Step 16
|
switch(config-port-monitor)# counter
tx-performance poll-interval seconds delta
rising-threshold percentage1 event event-id
falling-threshold2 percentage2 event event-id
|
Specifies the delta Tx counter poll interval in seconds and thresholds in percentage.
|
Step 17
|
switch(config-port-monitor)# no counter
sync-loss
|
Reverts to the default policy for sync loss performance counter values.
|
Step 18
|
switch(config-port-monitor)# no counter
tx-performance
|
Reverts to the default policy for Tx performance counter values.
|
Step 19
|
switch(config-port-monitor)# monitor counter
rx-datarate
|
Turns on Rx performance counter.
|
switch(config-port-monitor)# monitor counter
tx-datarate
|
Turns on Tx performance counter.
|
switch(config-port-monitor)# no monitor
counter tx-datarate
|
Turns off Tx performance counter.
|
switch(config-port-monitor)# no monitor
counter sync-loss
|
Turns off monitoring sync loss.
|
switch(config-port-monitor)# no monitor
counter state-change
|
Turns off monitoring state change.
|
Activating a Port Monitor Policy
Detailed Steps
To activate a port monitor policy, follow these steps:
|
Command
|
Purpose
|
Step 1
|
switch# config t
|
Enters configuration mode.
|
Step 2
|
switch(config)# port-monitor activate
policyname
|
Activates the specified port monitor policy.
|
switch(config)# port-monitor activate
|
Activates the default port monitor policy.
|
switch(config)# no port-monitor activate
policyname
|
Deactivates the specified port monitoring policy.
|
Configuring a Port Monitor Port Guard
Detailed Steps
To configure a port monitor policy, follow these steps:
|
Command
|
Purpose
|
Step 1
|
switch# config t
|
Enters configuration mode.
|
Step 2
|
switch(config)# port-monitor name policyname
|
Specifies the policy name and enters the port monitoring policy configuration mode.
|
switch(config)# no port-monitor name
policyname
|
Removes the policy.
|
Step 3
|
switch(config-port-monitor)# counter
link-loss poll-interval seconds delta
rising-threshold percentage1 event event-id
falling-threshold percentage2 event event-id
portguard flap
|
Specifies the delta link loss, poll interval in seconds, the thresholds in percentage, and the event IDs of events to be triggered. It also specifies that the port is flappped (is up or down) when the event occurs.
|
Step 4
|
switch(config-port-monitor)# counter
link-loss poll-interval seconds delta
rising-threshold percentage1 event event-id
falling-threshold percentage2 event event-id
portguard errordisable
|
Specifies the delta link loss, poll interval in seconds, the thresholds in percentage, and the event IDs of events to be triggered. It also specifies that the interface is down (error disabled) when the event occurs.
|
Note By default, the port monitor port guard is disabled. To enable this feature, you must explicitly configure the port monitor port guard feature on a particular counter by performing Step 3 or Step 4.
Configuring Port Group Monitor
This section includes the following topics:
•Enabling Port Group Monitor
•Configuring a Port Group Monitor Policy
•Reverting to the Default Policy for a Specific Counter
•Turning Off the Monitoring of Specific Counter
•Activating a Port Group Monitor Policy
Enabling Port Group Monitor
Detailed Steps
To enable port group monitor, follow these steps:
|
Command
|
Purpose
|
Step 1
|
switch# config t
|
Enters configuration mode.
|
Step 2
|
switch(config)# port-group-monitor enable
|
Enables (default) port group monitoring.
|
switch(config)# no port-group-monitor enable
|
Disables port group monitoring.
|
Configuring a Port Group Monitor Policy
Detailed Steps
To configure port group monitor policy, follow these steps:
|
Command
|
Purpose
|
Step 1
|
switch# config t
|
Enters configuration mode.
|
Step 2
|
switch(config)# port-group-monitor name
policyname
|
Specifies the policy name and enters the port group monitoring policy configuration mode.
|
switch(config)# no port-group-monitor name
policyname
|
Removes the policy.
|
Step 3
|
switch(config-port-group-monitor)# counter
rx-performance poll-interval seconds delta
rising-threshold percentage1
falling-threshold percentage2
|
Specifies the delta Rx counter poll interval in seconds and thresholds in percentage.
|
switch(config-port-group-monitor)# counter
tx-performance poll-interval seconds delta
rising-threshold percentage1
falling-threshold percentage2
|
Specifies the delta Tx counter poll interval in seconds and thresholds in percentage.
|
switch(config-port-group-monitor)# no
counter tx-performance
|
1 Reverts to the 2 default policy.
|
Step 4
|
switch(config-port-group-monitor)# monitor
counter rx-performance
|
Turns on Rx performance monitoring.
|
switch(config-port-group-monitor)# monitor
counter tx-performance
|
Turns on Tx performance monitoring.
|
switch(config-port-group-monitor)# no
monitor counter tx-performance
|
3 Turns off Tx performance monitoring.
|
Reverting to the Default Policy for a Specific Counter
When the no counter command is used in the config-port-group-monitor mode, the specified counter polling values will revert to the default values as seen in the following example:
switch(config)# port-group-monitor name PGMON_policy
switch(config-port-group-monitor)# counter tx-performance poll-interval 100 delta
rising-threshold 65 falling-threshold 25
switch(config)# show port-group-monitor PGMON_policy
Policy Name : PGMON_policy
Admin status : Not Active
Port type : All Port Groups
------------------------------------------------------------------------------------------
Counter Threshold Interval %ge Rising Threshold %ge Falling Threshold
------- --------- -------- -------------------- ---------------------
RX Performance Delta 60 80 10
TX Performance Delta 100 65 25
switch(config)# port-group-monitor name PGMON_policy
switch(config-port-group-monitor)# no counter tx-performance
switch(config)# show port-group-monitor PGMON_policy
Policy Name : PGMON_policy
Admin status : Not Active
Port type : All Port Groups
------------------------------------------------------------------------------------------
Counter Threshold Interval %ge Rising Threshold %ge Falling Threshold
------- --------- -------- -------------------- ----------------------
RX Performance Delta 60 80 10
TX Performance Delta 60 80 10
------------------------------------------------------------------------------------------
Turning Off the Monitoring of Specific Counter
When the no monitor counter command is used in the config-port-group-monitor mode, it turns off the monitoring of the specified counter in the given policy as seen in the following example:
switch(config)# show port-group-monitor PGMON_policy
Policy Name : PGMON_policy
Admin status : Not Active
Port type : All Port Groups
------------------------------------------------------------------------------------------
Counter Threshold Interval %ge Rising Threshold %ge Falling Threshold
------- --------- -------- -------------------- ----------------------
RX Performance Delta 26 450 250
TX Performance Delta 60 100 80
------------------------------------------------------------------------------------------
switch(config)# port-group-monitor name PGMON_policy
switch(config-port-group-monitor)# no monitor counter rx-performance
switch(config)# show port-group-monitor PGMON_policy
Policy Name : PGMON_policy
Admin status : Not Active
Port type : All Port Groups
------------------------------------------------------------------------------------------
Counter Threshold Interval %ge Rising Threshold %ge Falling Threshold
------- --------- -------- -------------------- ----------------------
RX Performance Delta 26 450 250
TX Performance Delta 60 100 80
------------------------------------------------------------------------------------------
Activating a Port Group Monitor Policy
To activate a port group monitor policy, follow these steps:
|
Command
|
Purpose
|
Step 1
|
switch# config t
|
Enters configuration mode.
|
Step 2
|
switch(config)# port-group-monitor activate
policyname
|
Activates the specified port group monitor policy.
|
switch(config)# port-group-monitor activate
|
Activates the default port group monitor policy.
|
switch(config)# no port-group-monitor
activate policyname
|
Deactivates the specified port group monitor policy.
|
Configuring Management Interfaces
Detailed Steps
To configure the mgmt0 Ethernet interface to connect over IPv4, follow these steps:
|
Command
|
Purpose
|
Step 1
|
switch# config terminal
switch(config)#
|
Enters configuration mode.
|
Step 2
|
switch(config)# interface mgmt0
switch(config-if)#
|
Selects the management Ethernet interface on the switch and enters interface configuration submode.
|
Step 3
|
switch(config-if)# ip address 10.16.1.2
255.255.255.0
|
Configures the IPv4 address and IPv4 subnet mask.
|
Step 4
|
switch(config-if)# no shutdown
|
Enables the interface.
|
Step 5
|
switch(config-if)# exit
switch(config)#
|
Returns to configuration mode.
|
Step 6
|
switch(config)# ip default-gateway 1.1.1.4
|
Configures the default gateway IPv4 address.
|
Step 7
|
switch(config)# exit
switch#
|
Returns to EXEC mode.
|
Step 8
|
switch# copy running-config startup-config
|
(Optional) Saves your configuration changes to the file system.
Note If you want to save your configuration, you can enter this command at any time.
|
To configure the mgmt0 Ethernet interface to connect over IPv6, follow these steps:
|
Command
|
Purpose
|
Step 1
|
switch# config terminal
switch(config)#
|
Enters configuration mode.
|
Step 2
|
switch(config)# interface mgmt0
switch(config-if)#
|
Selects the management Ethernet interface on the switch and enters interface configuration submode.
|
Step 3
|
switch(config-if)# ipv6 enable
|
Enables IPv6 and assigns a link-local address on the interface.
|
Step 4
|
switch(config-if)# ipv6 address ipv6
address 2001:0db8:800:200c::417a/64
|
Specifies an IPv6 unicast address and prefix length on the interface.
|
Step 5
|
switch(config-if)# no shutdown
|
Enables the interface.
|
Step 6
|
switch(config-if)# end
switch#
|
Returns to EXEC mode.
|
Step 7
|
switch# copy running-config startup-config
|
(Optional) Saves your configuration changes to the file system.
Note If you want to save your configuration, you can enter this command at any time.
|
Creating VSAN Interfaces
Detailed Steps
To create a VSAN interface, follow these steps:
|
Command
|
Purpose
|
Step 1
|
switch# config t
|
Enters configuration mode.
|
Step 2
|
switch(config)# interface vsan 2
switch(config-if)#
|
Configures a VSAN with the ID 2.
|
Step 3
|
switch(config-if)# no shutdown
|
Enables the VSAN interface.
|
Configuring Slow Drain Device Detection and Congestion Avoidance
This section includes the following topics:
•Configuring Congestion Frame Timeout Value
•Configuring Stuck Frame Timeout Value
•Configuring No-Credit Timeout Value
•Configuring Credit Loss Recovery Threshold and Action
•Configuring Average Credit Nonavailable Duration Threshold and Action
Configuring Congestion Frame Timeout Value
The default congestion frame timeout value is 500 milliseconds. We recommend that you retain the default configuration for the ISLs and configure a value that does not exceed the default value for the edge ports. If the frame is in the switch for a longer time than the configured congestion frame timeout, it gets dropped, which empties the buffer space in the ISL and alleviates the congestion.
To configure the congestion frame timeout value, follow these steps:
|
Command
|
Purpose
|
Step 1
|
switch# config t
|
Enters configuration mode.
|
Step 2
|
switch(config)# system default interface
congestion timeout milliseconds mode {core |
edge}
|
Configures a new congestion frame timeout value in milliseconds and the port mode for the device.
|
Step 3
|
switch(config)# system default interface
congestion mode {core | edge}
|
Configures the default congestion frame timeout value in milliseconds and the port mode for the device.
The congestion timeout range is 100-1000 milliseconds.
|
Step 4
|
switch# show logging onboard flow-control
request-timeout
|
(Optional) Displays the request timeout for a source-destination pair per module with the timestamp information.
|
Configuring Stuck Frame Timeout Value
The default stuck frame timeout value is 500 ms. We recommend that you retain the default configuration for ISLs and configure a value not exceeding 500 ms (100 to 200 ms) for fabric F ports.
To configure the stuck frame timeout value, follow these steps:
|
Command
|
Purpose
|
Step 1
|
switch# config t
|
Enters configuration mode.
|
Step 2
|
switch(config)# system timeout
congestion-drop seconds mode E|F
|
Specifies the stuck frame timeout value in ms and the port mode for the switch.
|
switch(config)# system timeout
congestion-drop default mode E|F
|
Specifies the default stuck frame timeout port mode for the switch.
|
Configuring No-Credit Timeout Value
When the port does not have the credits for the configured period, no-credit timeout can be enabled on that port. This will result in all frames coming to that port getting dropped in the egress. This will free the buffer space in the ISL link, which carries traffic for this port. This will help reduce fabric slow down and congestion on other unrelated flows using the same link.
The frames that will be dropped would have just entered the switch or would have stayed in the switch for the configured timeout value. These are preemptive drops and will clear the congestion completely compared to the stuck frame timeout value.
No-credit timeout feature is disabled by default. We recommend that you retain the default configuration for ISLs and configure a value not exceeding 500 ms (200 to 300 ms) for fabric F ports.
Note The no-credit timeout value and stuck frame timeout value are interlinked. The no-credit timeout value must always be greater than the stuck frame timeout value.
To configure the no-credit timeout value, follow these steps:
|
Command
|
Purpose
|
Step 1
|
switch# config t
|
Enters configuration mode.
|
Step 2
|
switch(config)# system timeout
no-credit-drop seconds mode E|F
|
Specifies the no-credit timeout value and port mode for the switch.
|
switch(config)# system timeout
no-credit-drop default mode E|F
|
Specifies the default no-credit timeout value port mode for the switch.
|
Configuring Credit Loss Recovery Threshold and Action
When the port detects the credit loss condition and recovers, then the port can be error-disabled, a trap can be sent with interface details, and a syslog can be generated with interface details. When the configured threshold is exceeded, one or more of these actions can be combined together. These actions can be turned on or off depending on situation. The port monitor feature provides the command line interface to configure the thresholds and action.
The thresholds are that the credit loss recovery can be between 1 and 10 and the interval can be 1 second to 1 hour. The default value is 3 in 10 minutes and generates a syslog.
When the port sees the credit loss condition and fails to recover, the port flaps. This function is already part of port guard, and you can configure the supported actions using the Port Guard feature.
To configure credit loss recovery threshold and action, refer to the following example. The following example shows the credit loss recovery threshold and action configuration:
switch# show port-monitor
------------------------------------------------------------------------------------------
Counter Threshold Interval Rising Threshold event Falling Threshold
event Portguard
------- --------- -------- ---------------- ----- ------------------ ----- --------- ---
Link Loss Delta 60 5 4 1 4
Not enabled
Sync Loss Delta 60 5 4 1 4
Not enabled
Protocol Error Delta 60 1 4 0 4
Not enabled
Signal Loss Delta 60 5 4 1 4
Not enabled
Invalid Words Delta 60 1 4 0 4
Not enabled
Invalid CRC's Delta 60 5 4 1 4
Not enabled
RX Performance Delta 60 2147483648 4 524288000 4
Not enabled
TX Performance Delta 60 2147483648 4 524288000 4
Not enabled
TX Discards Delta 60 200 4 10 4
Not enabled
LR RX Delta 60 5 4 1 4
Not enabled
LR TX Delta 60 5 4 1 4
Not enabled
Timeout Discards Delta 60 200 4 10 4
Not enabled
Credit Loss Reco Delta 60 1 4 0 4
Not enabled
TX Credit Not Available Delta 60 10 4 0 4
Not enabled
------------------------------------------------------------------------------------------
The following default port monitor policy will be active when the switch comes up:
Admin status : Not Active
------------------------------------------------------------------------------------------
----------
Counter Threshold Interval Rising Threshold event Falling Threshold
event Portguard
------- --------- -------- ---------------- ----- ------------------
----- --------- ------
Credit Loss Reco Delta 5 4 4 1 4
Not enabled
TX Credit Not Available Delta 1 20 4 10 4
Not enabled
------------------------------------------------------------------------------------------
Configuring Average Credit Nonavailable Duration Threshold and Action
When the average credit nonavailable duration exceeds the set threshold, the port can be error-disabled, a trap can be sent with interface details, and a syslog can be generated with interface details. One or more of these actions can also be combined together. These actions can be turned on or off depending on the situation. The port monitor feature provides the command line interface to configure the thresholds and action. The threshold configuration can be a percentage of credit nonavailable duration in an interval.
The thresholds are that the credit nonavailable duration can be 0 percent to 100 percent in multiples of 10, and the interval can be 1 second to 1 hour. The default is 10 percent in 1 second and generates a syslog.
To configure average credit nonavailable duration threshold and action, refer to the "Port Monitor" section.
Note This feature is not supported on 1 RU fabric switches.
Verifying Interfaces Configuration
This section includes the following topics:
•Displaying Interface Information
•Displaying TL Port Information
•Displaying the ALPA Cache Contents
•Displaying Port Monitor Status and Policies
•Displaying Port Group Monitor Status and Policies
•Displaying Management Interface Configuration
•Displaying VSAN Interface Information
Displaying Interface Information
The show interface command is invoked from the EXEC mode and displays the interface configurations. Without any arguments, this command displays the information for all the configured interfaces in the switch. See Examples 2-3 to 2-10.
Example 2-3 Displays All Interfaces
Hardware is Fibre Channel, SFP is short wave laser
Port WWN is 20:0b:00:05:30:00:8d:de
Port mode is F, FCID is 0x610000
Receive data field Size is 2112
5 minutes input rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
5 minutes output rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
134 frames input, 8468 bytes
154 frames output, 46072 bytes
1 input OLS, 1 LRR, 0 NOS, 0 loop inits
1 output OLS, 0 LRR, 1 NOS, 0 loop inits
16 receive B2B credit remaining
3 transmit B2B credit remaining.
Hardware is Fibre Channel, SFP is long wave laser cost reduced
Port WWN is 20:09:00:05:30:00:97:9e
Peer port WWN is 20:0b:00:0b:5f:a3:cc:00
Admin port mode is E, trunk mode is on
Transmit B2B Credit is 255
Receive B2B Credit is 255
Receive data field Size is 2112
Trunk vsans (admin allowed and active) (1,100,3000)
Trunk vsans (up) (1,100,3000)
Trunk vsans (isolated) ()
Trunk vsans (initializing) ()
5 minutes input rate 280 bits/sec, 35 bytes/sec, 0 frames/sec
5 minutes output rate 176 bits/sec, 22 bytes/sec, 0 frames/sec
4609939 frames input, 8149405708 bytes
4638491 frames output, 7264731728 bytes
3 input OLS, 9 LRR, 1 NOS, 0 loop inits
9 output OLS, 7 LRR, 1 NOS, 0 loop inits
16 receive B2B credit remaining
3 transmit B2B credit remaining.
Hardware is Fibre Channel, SFP is short wave laser
Port WWN is 20:0d:00:05:30:00:97:9e
Admin port mode is auto, trunk mode is on
Port mode is F, FCID is 0x650100
Receive data field Size is 2112
5 minutes input rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
5 minutes output rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
8696 frames input, 3227212 bytes
16799 frames output, 6782444 bytes
0 input OLS, 0 LRR, 0 NOS, 0 loop inits
1 output OLS, 1 LRR, 0 NOS, 1 loop inits
16 receive B2B credit remaining
3 transmit B2B credit remaining.
Hardware is Fibre Channel
139597 packets input, 13852970 bytes
0 multicast frames, 0 compressed
0 input errors, 0 frame, 0 overrun 0 fifo
139516 packets output, 16759004 bytes, 0 underruns
0 output errors, 0 collisions, 0 fifo
You can also specify arguments (a range of interfaces or multiple, specified interfaces) to display interface information. You can specify a range of interfaces by issuing a command with the following example format:
interface fc1/1 - 5 , fc2/5 - 7
Note The spaces are required before and after the dash ( - ) and before and after the comma ( , ).
Example 2-4 Displays Multiple, Specified Interfaces
switch# show interface fc3/13 , fc3/16
Hardware is Fibre Channel, SFP is short wave laser
Port WWN is 20:8d:00:05:30:00:97:9e
Port mode is F, FCID is 0x7b0300
Receive data field Size is 2112
5 minutes input rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
5 minutes output rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
1856 frames input, 116632 bytes
1886 frames output, 887712 bytes
0 input OLS, 0 LRR, 0 NOS, 1 loop inits
1 output OLS, 1 LRR, 0 NOS, 1 loop inits
16 receive B2B credit remaining
3 transmit B2B credit remaining.
Hardware is Fibre Channel, SFP is short wave laser
Port WWN is 20:90:00:05:30:00:97:9e
Port mode is F, FCID is 0x7d0100
Receive data field Size is 2112
5 minutes input rate 504 bits/sec, 63 bytes/sec, 0 frames/sec
5 minutes output rate 520 bits/sec, 65 bytes/sec, 0 frames/sec
47050 frames input, 10311824 bytes
62659 frames output, 10676988 bytes
0 input OLS, 0 LRR, 0 NOS, 0 loop inits
1 output OLS, 1 LRR, 0 NOS, 1 loop inits
16 receive B2B credit remaining
3 transmit B2B credit remaining.
Example 2-5 Displays a Specific Interface
switch# show interface fc2/2
Port description is Trunk to Core-4
Hardware is Fibre Channel, SFP is short wave laser
Port WWN is 20:42:00:05:30:00:97:9e
Peer port WWN is 20:cc:00:05:30:00:50:9e
Admin port mode is E, trunk mode is on
Transmit B2B Credit is 255
Receive B2B Credit is 255
Receive data field Size is 2112
Belongs to port-channel 2
Trunk vsans (admin allowed and active) (1,100,3000)
Trunk vsans (isolated) (100,3000)
Trunk vsans (initializing) ()
5 minutes input rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
5 minutes output rate 32 bits/sec, 4 bytes/sec, 0 frames/sec
2214834 frames input, 98673588 bytes
2262415 frames output, 343158368 bytes
1 input OLS, 1 LRR, 1 NOS, 0 loop inits
2 output OLS, 1 LRR, 0 NOS, 0 loop inits
16 receive B2B credit remaining
3 transmit B2B credit remaining.
Example 2-6 Displays Port Description
switch# show interface description
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Example 2-7 Displays Interface Information in a Brief Format
switch# show interface brief
-------------------------------------------------------------------------------
Interface Vsan Admin Admin Status SFP Oper Oper Port
Mode Trunk Mode Speed Channel
-------------------------------------------------------------------------------
fc1/1 1 E on trunking swl TE 2 1
fc1/2 1 E on trunking swl TE 2 1
fc1/3 1 auto on SFPAbsent -- -- --
fc1/4 1 auto on SFPAbsent -- -- --
fc1/5 3000 auto on up swl F 2 --
fc2/2 1 E on trunking swl TE 2 2
fc2/3 1 auto on down c1610 -- --
fc2/4 1 auto on down c1590 -- --
fc2/5 3000 auto on notConnected lwcr -- --
fc2/6 1 auto on SFPAbsent -- -- --
fc3/16 3000 FX -- up swl F 2 --
fc3/17 1 FX -- SFPAbsent -- -- --
-------------------------------------------------------------------------------
Interface Status IP Address Speed MTU
-------------------------------------------------------------------------------
GigabitEthernet4/1 SFPAbsent -- auto 1500
GigabitEthernet4/6 down 10.1.1.2/8 auto 3000
GigabitEthernet4/7 down 10.1.1.27/24 auto 1500
GigabitEthernet4/8 down -- auto 1500
-------------------------------------------------------------------------------
Interface Status Oper Mode Oper Speed
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Interface Status IP Address Speed MTU
-------------------------------------------------------------------------------
mgmt0 up 172.19.48.96/25 100 Mbps 1500
-------------------------------------------------------------------------------
Interface Vsan Admin Status Oper Oper
-------------------------------------------------------------------------------
port-channel 1 1 on trunking TE 4
port-channel 2 1 on trunking TE 4
-------------------------------------------------------------------------------
Interface Vsan Admin Admin Status Oper Profile Port-channel
-------------------------------------------------------------------------------
fcip10 1 auto on notConnected -- 10 --
Example 2-8 Displays Interface Counters
switch# show interface counters
5 minutes input rate 24 bits/sec, 3 bytes/sec, 0 frames/sec
5 minutes output rate 16 bits/sec, 2 bytes/sec, 0 frames/sec
3502 frames input, 268400 bytes
0 discards, 0 CRC, 0 unknown class
3505 frames output, 198888 bytes
1 input OLS, 1 LRR, 1 NOS, 0 loop inits
2 output OLS, 1 LRR, 1 NOS, 0 loop inits
1 link failures, 1 sync losses, 1 signal losses
5 minutes input rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
5 minutes output rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
0 class-2 frames, 0 bytes
0 class-3 frames, 0 bytes
0 class-f frames, 0 bytes
0 discards, 0 CRC, 0 unknown class
0 class-2 frames, 0 bytes
0 class-3 frames, 0 bytes
0 class-f frames, 0 bytes
0 input OLS, 0 LRR, 0 NOS, 0 loop inits
0 output OLS, 0 LRR, 0 NOS, 0 loop inits
0 link failures, 0 sync losses, 0 signal losses
16 receive B2B credit remaining
3 transmit B2B credit remaining.
114000 packets input, 11585632 bytes
0 multicast frames, 0 compressed
0 input errors, 0 frame, 0 overrun 0 fifo
113997 packets output, 10969672 bytes, 0 underruns
0 output errors, 0 collisions, 0 fifo
31557 packets input, 2230860 bytes
0 multicast frames, 0 compressed
0 input errors, 0 frame, 0 overrun 0 fifo
26618 packets output, 16824342 bytes, 0 underruns
0 output errors, 0 collisions, 7 fifo
0 packets input, 0 bytes, 0 errors, 0 multicast
0 packets output, 0 bytes, 0 errors, 0 dropped
5 minutes input rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
5 minutes output rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
0 class-2 frames, 0 bytes
0 class-3 frames, 0 bytes
0 class-f frames, 0 bytes
0 discards, 0 CRC, 0 unknown class
0 class-2 frames, 0 bytes
0 class-3 frames, 0 bytes
0 class-f frames, 0 bytes
0 input OLS, 0 LRR, 0 NOS, 0 loop inits
0 output OLS, 0 LRR, 0 NOS, 0 loop inits
0 link failures, 0 sync losses, 0 signal losses
Note Interfaces 9/8 and 9/9 are not trunking ports and display class 2, 3, and F information as well.
Example 2-9 Displays Interface Counters in Brief Format
switch# show interface counters brief
-------------------------------------------------------------------------------
Interface Input (rate is 5 min avg) Output (rate is 5 min avg)
----------------------------- -----------------------------
Mbits/s Frames Mbits/s Frames
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Interface Input (rate is 5 min avg) Output (rate is 5 min avg)
----------------------------- -----------------------------
Mbits/s Frames Mbits/s Frames
-------------------------------------------------------------------------------
port-channel 2 0 3946 0 3946
Note The show interface transceiver command can only be issued on a switch in the Cisco MDS 9100 Series if the SFP is present (see Example 2-10).
Example 2-10 Displays Transceiver Information
switch# show interface transceiver
part number is QFBR-5796L
serial number is A00162193
fc-transmitter type is short wave laser
cisco extended id is unknown (0x0)
part number is FTRJ-1319-7D-CSC
fc-transmitter type is long wave laser cost reduced
cisco extended id is unknown (0x0)
Example 2-11 displays the entire running configuration with information for all interfaces. The interfaces have multiple entries in the configuration files to ensure that the interface configuration commands execute in the correct order when the switch reloads.
Example 2-11 Displays the Running Configuration for All Interfaces
switch# show running-config
Example 2-12 displays the running configuration information for a specified interface. The interface configuration commands are grouped together.
Example 2-12 Displays the Running Configuration for a Specified Interface
switch# show running-config interface fc1/1
Example 2-13 displays the running configuration after the system default switchport mode F command is executed.
Example 2-13 Displays the Running Configuration After the System Default Switchport Mode F Command is Executed
switch# show running-config
system default switchport mode F
Example 2-14 displays the running configuration after two interfaces are individually configured for mode FL.
Example 2-14 Displays the Running Configuration After Two Interfaces Are Individually Configured for Mode FL
switch# show running-config
system default switchport mode F
Example 2-15 displays interface information in a brief format after the system default switchport mode F command is executed. Example 2-16 displays interface information in a brief format after two interfaces are individually configured for mode FL.
Example 2-15 Displays Interface Information in a Brief Format After the System Default Switchport Mode F Command is Executed
switch# show interface brief
-------------------------------------------------------------------------------
Interface Vsan Admin Admin Status SFP Oper Oper Port
Mode Trunk Mode Speed Channel
-------------------------------------------------------------------------------
fc4/1 1 F -- notConnected swl -- --
fc4/2 1 F -- notConnected swl -- --
fc4/3 1 F -- notConnected swl -- --
fc4/4 1 F -- notConnected swl -- --
fc4/5 1 F -- sfpAbsent -- -- --
fc4/6 1 F -- sfpAbsent -- -- --
fc4/7 1 F -- sfpAbsent -- -- --
fc4/8 1 F -- sfpAbsent -- -- --
fc4/9 1 F -- sfpAbsent -- -- --
Example 2-16 Displays Interface Information in a Brief Format After Two Interfaces Are Individually Configured for Mode FL
switch# show interface brief
-------------------------------------------------------------------------------
Interface Vsan Admin Admin Status SFP Oper Oper Port
Mode Trunk Mode Speed Channel
-------------------------------------------------------------------------------
fc4/1 1 FL -- notConnected swl -- --
fc4/2 1 F -- notConnected swl -- --
fc4/3 1 FL -- notConnected swl -- --
fc4/4 1 F -- notConnected swl -- --
fc4/5 1 F -- sfpAbsent -- -- --
fc4/6 1 F -- sfpAbsent -- -- --
fc4/7 1 F -- sfpAbsent -- -- --
fc4/8 1 F -- sfpAbsent -- -- --
fc4/9 1 F -- sfpAbsent -- -- --
fc4/10 1 F -- sfpAbsent -- -- --
Displaying TL Port Information
The show tlport command displays the TL port interface configurations. This command provides a list of all TL ports configured in a switch and shows the associated VSAN, the FC ID for the port (only domain and area are valid), and the current operational state of the TL port (up or initializing). See Example 2-17 through Example 2-20.
Example 2-17 Displays the TL Ports in All VSANs
-------------------------------
Interface Vsan FC-ID State
------------------------- ------
TL ports allow a private device (devices that physically reside on the loop) to see a fabric device and vice-versa by proxying fabric devices on the loop. Fabric devices are proxied by allocating each fabric device an ALPA on this loop.
In addition to these proxied devices, other virtual devices (local or remote domain controller addresses) are also allocated ALPAs on the loop. A switch reserves the ALPA for its own communication with private devices, and the switch acts as a SCSI initiator.
The first column in the output of the show tlport interface command is the ALPA identity of the device on the loop. The columns that follow include the port WWNs, the node WWNs for each device, the device as a SCSI initiator or target, and the real FC ID of the device.
Example 2-18 Displays the Detailed Information for a Specific TL Port
switch# show tlport interface fc1/16 all
fc1/16 is up, vsan 1, FCID 0x420000
--------------------------------------------------------------------------------
alpa pWWN nWWN SCSI Type Device FC-ID
--------------------------------------------------------------------------------
0x01 20:10:00:05:30:00:4a:de 20:00:00:05:30:00:4a:de Initiator Proxied 0xfffc42
0x73 22:00:00:20:37:39:ae:54 20:00:00:20:37:39:ae:54 Target Private 0x420073
0xef 20:10:00:05:30:00:4a:de 20:00:00:05:30:00:4a:de Initiator Switch 0x0000ef
Example 2-19 Displays TL Port Information for Private Devices
switch# show tlport interface fc 1/16 private
fc1/16 is up, vsan 1, FCID 0x420000
------------------------------------------------------------------------
alpa pWWN nWWN SCSI Type FC-ID
------------------------------------------------------------------------
0x73 22:00:00:20:37:39:ae:54 20:00:00:20:37:39:ae:54 Target 0x420073
0x74 22:00:00:20:37:38:d3:de 20:00:00:20:37:38:d3:de Target 0x420074
Example 2-20 Displays TL Port Information for Proxied Devices
switch# show tlport interface fc 1/16 proxied
fc1/16 is up, vsan 1, FCID 0x420000
------------------------------------------------------------------------
alpa pWWN nWWN SCSI Type FC-ID
------------------------------------------------------------------------
0x01 20:10:00:05:30:00:4a:de 20:00:00:05:30:00:4a:de Initiator 0xfffc42
0x02 21:00:00:e0:8b:01:95:e7 20:00:00:e0:8b:01:95:e7 Initiator 0x420100
Displaying the ALPA Cache Contents
The show tlport alpa-cache command displays the contents of the ALPA cache.
switch# show tlport alpa-cache
---------------------------------------------------------
---------------------------------------------------------
0x02 22:00:00:20:37:46:09:bd fc1/2
0x04 23:00:00:20:37:46:09:bd fc1/2
The first entry indicates that if a device with a pWWN of 22:00:00:20:37:46:09:bd is exported on TL port fc1/2, then the pWWN is allocated an alpa 0x02 (if available).
Displaying Port Monitor Status and Policies
The following commands display information regarding port monitor:
switch# show port-monitor status
switch# show port-monitor
------------------------------------------------------------------------------------------
------------------------------------------------------------------------------------------
Admin status : Not Active
------------------------------------------------------------------------------------------
Counter Threshold Interval Rising Threshold event Falling Threshold event
portguard
------- --------- -------- ---------------- ----- ------------------ ----- -----
Link Loss Delta 60 5 4 1 4
Sync Loss Delta 60 5 4 1 4
Protocol Error Delta 60 1 4 0 4
Signal Loss Delta 60 5 4 1 4
Invalid Words Delta 60 1 4 0 4
Invalid CRC's Delta 60 5 4 1 4
RX Performance Delta 60 2147483648 4 524288000 4
TX Performance Delta 60 2147483648 4 524288000 4
------------------------------------------------------------------------------------------
Admin status : Not Active
------------------------------------------------------------------------------------------
Counter Threshold Interval Rising Threshold event Falling Threshold event
portguard
------- --------- -------- ---------------- ----- ------------------ ----- -----
Link Loss Delta 60 5 4 1 4
Sync Loss Delta 60 5 4 1 4
Protocol Error Delta 60 1 4 0 4
Signal Loss Delta 60 5 4 1 4
Invalid Words Delta 60 1 4 0 4
Invalid CRC's Delta 60 5 4 1 4
RX Performance Delta 60 2147483648 4 524288000 4
TX Performance Delta 60 2147483648 4 524288000 4
------------------------------------------------------------------------------------------
switch# show port-monitor active
Port type : All Access Ports
------------------------------------------------------------------------------------------
Counter Threshold Interval Rising Threshold event Falling Threshold event
portguard
------- --------- -------- ---------------- ----- ------------------ ----- -----
Link Loss Delta 60 5 4 1 4
Sync Loss Delta 60 5 4 1 4
Protocol Error Delta 60 1 4 0 4
Signal Loss Delta 60 5 4 1 4
Invalid Words Delta 60 1 4 0 4
Invalid CRC's Delta 60 5 4 1 4
RX Performance Delta 60 2147483648 4 524288000 4
TX Performance Delta 60 2147483648 4 524288000 4
------------------------------------------------------------------------------------------
switch# show port-monitor sample
Port type : All Access Ports
------------------------------------------------------------------------------------------
Counter Threshold Interval Rising Threshold event Falling Threshold event
portgurard
------- --------- -------- ---------------- ----- ------------------ ----- -----
Link Loss Delta 60 5 4 1 4
Sync Loss Delta 60 5 4 1 4
Protocol Error Delta 60 1 4 0 4
Signal Loss Delta 60 5 4 1 4
Invalid Words Delta 60 1 4 0 4
Invalid CRC's Delta 60 5 4 1 4
RX Performance Delta 60 2147483648 4 524288000 4
TX Performance Delta 60 2147483648 4 524288000 4
------------------------------------------------------------------------------------------
Displaying Port Group Monitor Status and Policies
The following commands display information about port group monitor:
switch# show port-group-monitor status
Port Group Monitor : Enabled
switch# show port-group-monitor
------------------------------------------------------------------------------------------
Port Group Monitor : enabled
------------------------------------------------------------------------------------------
Admin status : Not Active
Port type : All Port Groups
------------------------------------------------------------------------------------------
Counter Threshold Interval %ge Rising Threshold %ge Falling Threshold
------- --------- -------- -------------------- ----------------------
RX Performance Delta 60 50 10
TX Performance Delta 60 50 10
------------------------------------------------------------------------------------------
Port type : All Port Groups
------------------------------------------------------------------------------------------
Counter Threshold Interval %ge Rising Threshold %ge Falling Threshold
------- --------- -------- -------------------- ----------------------
RX Performance Delta 60 80 10
TX Performance Delta 60 80 10
------------------------------------------------------------------------------------------
Admin status : Not Active
Port type : All Port Groups
------------------------------------------------------------------------------------------
Counter Threshold Interval %ge Rising Threshold %ge Falling Threshold
------- --------- -------- -------------------- ----------------------
RX Performance Delta 60 80 20
TX Performance Delta 60 80 20
------------------------------------------------------------------------------------------
switch# show port-group-monitor active
Port type : All Port Groups
------------------------------------------------------------------------------------------
Counter Threshold Interval %ge Rising Threshold %ge Falling Threshold
------- --------- -------- -------------------- ----------------------
RX Performance Delta 60 80 10
TX Performance Delta 60 80 10
------------------------------------------------------------------------------------------
switch# show port-group-monitor PGMON_policy
PPolicy Name : PGMON_policy
Admin status : Not Active
Port type : All Port Groups
------------------------------------------------------------------------------------------
Counter Threshold Interval %ge Rising Threshold %ge Falling Threshold
------- --------- -------- -------------------- ----------------------
RX Performance Delta 26 450 250
TX Performance Delta 60 100 80
------------------------------------------------------------------------------------------
Displaying Management Interface Configuration
To display the management interface configuration, use the show interface mgmt 0 command.
switch# show interface mgmt 0
Address is 000c.30d9.fdbc
Internet address is 10.16.1.2/24
MTU 1500 bytes, BW 100 Mbps full Duplex
26388 packets input, 6101647 bytes
0 multicast frames, 0 compressed
0 input errors, 0 frame, 0 overrun 0 fifo
10247 packets output, 2389196 bytes, 0 underruns
0 output errors, 0 collisions, 0 fifo
Displaying VSAN Interface Information
To display VSAN interface information, use the show interface vsan command.
switch# show interface vsan 2
vsan2 is up, line protocol is up
WWPN is 10:00:00:05:30:00:59:1f, FCID is 0xb90100
Internet address is 10.1.1.1/24
MTU 1500 bytes, BW 1000000 Kbit
0 packets input, 0 bytes, 0 errors, 0 multicast
0 packets output, 0 bytes, 0 errors, 0 dropped