Server Specifications
This appendix lists the physical, environmental, and power specifications for the node.
Physical Specifications
The following table lists the physical specifications for the node.
Description |
Specification |
Height |
1.7 in. (43.2 mm) |
Width |
16.9 in. (429.0 mm) |
Depth (length) |
Server only: 30 in. (762 mm) Server with slide rail: 31.5 in (800.1 mm) |
Weight |
|
Environmental Specifications
As a Class A2 product, the node has the following environmental specifications.
Description |
Specification |
Temperature, Operating |
Dry bulb temperature of 10°C to 35°C (50°F to 95°F) Maximum temperature change of 20°C (36°F) per hour (a temperature change within a specified period of time and not a rate of change) Humidity condition: Uncontrolled, not to exceed 50% RH starting condition Derate the maximum temperature by 1°C (33.8°F) per every 305 meters of altitude above 900m |
Temperature, Extended Operating |
5°C to 40°C (41°F to 104°F) with no direct sunlight Humidity condition: Uncontrolled, not to exceed 50% RH starting condition Derate the maximum temperature by 1°C (33.8°F) per every 305 meters of altitude above 900m |
Temperature, non-operating (when the node is stored or transported) |
Dry bulb temperature of 40 °C to 65 °C (-40°F to 149 °F) |
Humidity (RH), operating |
10% to 90% and 28°C (82.4°F) maximum dew-point temperature, non-condensing environment Minimum to be higher (more moisture) of -12 ˚C (10.4 ˚F) dew point or 8% relative humidity Maximum to be 24 ˚C (75.2 ˚F) dew point or 90% relative humidity |
Humidity (RH), non-operating (when the node is stored or transported) |
5% to 93% relative humidity, non-condensing, with a maximum wet bulb temperature of 28 °C across the 20 °C to 40 °C dry bulb range. |
Altitude, operating |
A maximum elevation of 3050 meters (10,006 feet) |
Altitude, non-operating (when the node is stored or transported) |
An elevation of 0 to 12,000 meters (39,370 feet) |
Maximum Operating Duration |
Unlimited |
Sound power level Measure A-weighted per ISO7779 LwAd (Bels) Operation at 73°F (23°C) |
5.5 |
Sound pressure level Measure A-weighted per ISO7779 LpAm (dBA) Operation at 73°F (23°C) |
40 |
Power Specifications
Note |
Do not mix power supply types or wattages in the node. Both power supplies must be identical. |
You can get more specific power information for your exact node configuration by using the Cisco UCS Power Calculator:
The power specifications for the supported power supply options are listed in the following sections.
1050 W AC Power Supply
Note |
For the 80PLUS platinum certification documented in the following table, you can find test results at https://www.clearesult.com/80plus/. |
Parameter |
Specification |
|||
---|---|---|---|---|
Input Connector |
IEC320 C14 |
|||
Input Voltage Range (V rms) |
100 to 240 |
|||
Maximum Allowable Input Voltage Range (V rms) |
90 to 264 |
|||
Frequency Range (Hz) |
50 to 60 |
|||
Maximum Allowable Frequency Range (Hz) |
47 to 63 |
|||
Maximum Rated Output (W) Limited to 800W when operating at low-line input voltage, 100-127 V |
800 |
1050 | ||
Maximum Rated Standby Output (W) |
36 |
|||
Nominal Input Voltage (V rms) |
100 |
120 |
208 |
230 |
Nominal Input Current (A rms) |
9.2 |
7.6 |
5.8 |
5.2 |
Maximum Input at Nominal Input Voltage (W) |
889 |
889 |
1167 |
1154 |
Maximum Input at Nominal Input Voltage (VA) |
916 |
916 |
1203 |
1190 |
Maximum Rated Efficiency (%) Minimum rating required to achieve 80PLUS platinum certification. |
90 |
90 |
90 |
91 |
Maximum Rated Power Factor Minimum rating required to achieve 80PLUS platinum certification. |
0.97 |
0.97 |
0.97 |
0.97 |
Maximum Inrush Current (peak A) |
15 |
|||
Maximum Inrush Current (ms) |
0.2 |
|||
Maximum Ride-Through Time Time output voltage remains within regulation limits at 100% load, during input voltage dropout |
12 |
1050 W V2 DC Power Supply
Note |
For the 80PLUS platinum certification documented in the following table, you can find test results at https://www.clearesult.com/80plus/. |
Parameter |
Specification |
|||
---|---|---|---|---|
Input Connector |
Molex 42820 |
|||
Input Voltage Range (V rms) |
-48 |
|||
Maximum Allowable Input Voltage Range (V rms) |
-40 to -72 |
|||
Frequency Range (Hz) |
NA |
|||
Maximum Allowable Frequency Range (Hz) |
NA |
|||
Maximum Rated Output (W) |
1050 |
|||
Maximum Rated Standby Output (W) |
36 |
|||
Nominal Input Voltage (V rms) |
-48 |
|||
Nominal Input Current (A rms) |
24 |
|||
Maximum Input at Nominal Input Voltage (W) |
1154 |
|||
Maximum Input at Nominal Input Voltage (VA) |
1154 |
|||
Maximum Rated Efficiency (%) Minimum rating required to achieve 80PLUS platinum certification. |
91 |
|||
Maximum Rated Power Factor Minimum rating required to achieve 80PLUS platinum certification. |
NA |
|||
Maximum Inrush Current (peak A) |
15 |
|||
Maximum Inrush Current (ms) |
0.2 |
|||
Maximum Ride-Through Time This is the time output voltage remains within regulation limits at 100% load, during input voltage dropout |
5 |
1600 W AC Power Supply
Note |
For the 80PLUS platinum certification documented in the following table, you can find test results at https://www.clearesult.com/80plus/. |
Parameter |
Specification |
|||
---|---|---|---|---|
Input Connector |
IEC320 C14 |
|||
Input Voltage Range (V rms) |
200 to 240 |
|||
Maximum Allowable Input Voltage Range (V rms) |
180 to 264 |
|||
Frequency Range (Hz) |
50 to 60 |
|||
Maximum Allowable Frequency Range (Hz) |
47 to 63 |
|||
Maximum Rated Output (W) Limited to 800W when operating at low-line input voltage, 100-127 V |
1600 |
|||
Maximum Rated Standby Output (W) |
36 |
|||
Nominal Input Voltage (V rms) |
100 |
120 |
208 |
230 |
Nominal Input Current (A rms) |
NA |
NA |
8.8 |
7.9 |
Maximum Input at Nominal Input Voltage (W) |
NA |
NA |
1778 |
1758 |
Maximum Input at Nominal Input Voltage (VA) |
NA |
NA |
1833 |
1813 |
Maximum Rated Efficiency (%) Minimum rating required to achieve 80PLUS platinum certification. |
NA |
NA |
90 |
91 |
Maximum Rated Power Factor Minimum rating required to achieve 80PLUS platinum certification. |
NA |
NA |
0.97 |
0.97 |
Maximum Inrush Current (peak A) |
30 |
|||
Maximum Inrush Current (ms) |
0.2 |
|||
Maximum Ride-Through Time The time that the output voltage remains within regulation limits at 100% load, during input voltage dropout |
12 |
2300 W AC Power Supply
Note |
For the 80PLUS platinum certification documented in the following table, you can find test results at https://www.clearesult.com/80plus/. |
Parameter |
Specification |
|||
---|---|---|---|---|
Input Connector |
IEC320 C20 |
|||
Input Voltage Range (V rms) |
100 to 240 |
|||
Maximum Allowable Input Voltage Range (V rms) |
90 to 264 |
|||
Frequency Range (Hz) |
50 to 60 |
|||
Maximum Allowable Frequency Range (Hz) |
47 to 63 |
|||
Maximum Rated Output (W) Limited to 800W when operating at low-line input voltage, 100-127 V |
2300 |
|||
Maximum Rated Standby Output (W) |
36 |
|||
Nominal Input Voltage (V rms) |
100 |
120 |
208 |
230 |
Nominal Input Current (A rms) |
13 |
11 |
12 |
10.8 |
Maximum Input at Nominal Input Voltage (W) |
1338 |
1330 |
2490 |
2480 |
Maximum Input at Nominal Input Voltage (VA) |
1351 |
1343 |
2515 |
2505 |
Maximum Rated Efficiency (%) Minimum rating required to achieve 80PLUS platinum certification. |
92 |
92 |
93 |
93 |
Maximum Rated Power Factor Minimum rating required to achieve 80PLUS platinum certification. |
0.99 |
0.99 |
0.97 |
0.97 |
Maximum Inrush Current (peak A) |
30 |
|||
Maximum Inrush Current (ms) |
0.2 |
|||
Maximum Ride-Through Time Time output voltage remains within regulation limits at 100% load, during input voltage dropout |
12 |
Power Cord Specifications
Each power supply in the node has a power cord. Standard power cords or jumper power cords are available for connection to the node. The shorter jumper power cords, for use in racks, are available as an optional alternative to the standard power cords.
Note |
Only the approved power cords or jumper power cords listed below are supported. The following tables show the supported power cords supported for less than 2300-Watt node PSUs, and more than 2300-Watt node PSUs. |
Description |
Length (Feet) |
Length (Meters) |
CAB-48DC-40A-8AWG DC power cord, -48 VDC, 40 A, 8 AWG Three-socket Mini-Fit connector to three-wire |
11.7 |
3.5 |
CAB-C13-C14-AC AC power cord, 10 A; C13 to C14, recessed receptacle |
9.8 |
3.0 |
CAB-250V-10A-AR AC power cord, 250 V, 10 A Argentina |
8.2 |
2.5 |
CAB-C13-C14-2M-JP AC Power Cord, C13 to C14 Japan PSE Mark |
6.6 |
2.0 |
CAB-9K10A-EU AC Power Cord, 250 V, 10 A; CEE 7/7 Plug Europe |
8.2 |
2.5 |
CAB-250V-10A-IS AC Power Cord, SFS, 250 V, 10 A Israel |
8.2 |
2.5 |
CAB-250V-10A-CN AC power cord, 250 V, 10 A PR China |
8.2 |
2.5 |
CAB-ACTW AC power cord, 250 V, 10 A, C13 EL302 Taiwan |
7.5 |
2.3 |
CAB-C13-CBN AC cabinet jumper power cord, 250, 10 A, C13 to C14 |
2.2 |
0.68 |
CAB-C13-C14-2M AC cabinet jumper power cord, 250 V, 10 A, C13 to C14 |
6.6 |
2.0 |
CAB-9K10A-AU AC power cord, 250 V, 10 A, 3112 plug, Australia |
8.2 |
2.5 |
CAB-N5K6A-NA AC power cord, 200/240 V, 6 A, North America |
8.2 |
2.5 |
CAB-250V-10A-ID AC power Cord, 250 V, 10 A, India |
8.2 |
2.5 |
CAB-9K10A-SW AC power cord, 250 V, 10 A, MP232 plug Switzerland |
8.2 |
2.5 |
CAB-250V-10A-BR AC power Cord, 250 V, 10 A Brazil |
8.2 |
2.5 |
CAB-9K10A-UK AC power cord, 250 V, 10 A (13 A fuse), BS1363 plug United Kingdom |
8.2 |
2.5 |
CAB-9K12A-NA AC power cord, 125 V, 13 A, NEMA 5-15 plug North America |
8.2 |
2.5 |
CAB-AC-L620-C13 AC power cord, NEMA L6-20 to C13 connectors |
6.6 |
2.0 |
CAB-9K10A-IT AC power cord, 250 V, 10 A, CEI 23-16/VII plug Italy |
8.2 |
2.5 |
CAB-C13-C14-3M-IN AC power cord jumper, C13 to C14 connector India |
9.8 |
3.0 |
CAB-C13-C14-IN AC power cord jumper, C13 to C14 connector India |
4.6 |
1.4 |
CAB-9K10A-KOR Power Cord, 125 V AC, 13 A, KSC8305 plug Korea |
6 |
1.8 |
CAB-JPN-3PIN 90-125 V AC, 12 A, NEMA 5-15 plug Japan |
2.4 |
|
R2XX-DMYMPWRCORD No power cord; PID option for ordering node with no power cord |
NA |
NA |
Description |
Length (Feet) |
Length (Meters) |
CAB-C19-CBN Cabinet Jumper Power Cord, 250 VAC, 16A, C20 to C19 connector |
||
CAB-S132-C19-ISRL S132 to IEC320 C19 connector Israel |
14 |
|
CAB-IR2073-C19-AR IRSM 2073 to IEC320 C19 connector Argentina |
14 |
|
CAB-BS1363-C19-UK BS-1363 to IEC 320 C19 connector UK |
14 |
|
CAB-SABS-C19-IND SABS 164-1 to IEC 320 C19 connector India |
||
CAB-C2316-C19-IT CEI 23-16 to IEC 320 C19 Italy |
14 |
|
CAB-L520P-C19-US NEMA L5-20 to IEC 320 C19 US |
6 |
|
CAB-US515P-C19-US NEMA 5-15 to IEC 320 C19 US |
13 |
|
CAB-US520-C19-US NEMA 5-20 to IEC 320 C19 US |
14 |
|
CAB-US620P-C19-US NEMA 6-20 to IEC-C19 US |
13 |
|
CAB-C19-C20-IND Power Cord C19 to C20 connector India |
||
UCSB-CABL-C19-BRZ AC power cord NBR 14136 to C19 connector Brazil |
14 |
|
CAB-9K16A-BRZ AC Power Cord, 250 V, 16 A, Source Plug EL224 to C19 connector Brazil |
||
CAB-ACS-16 AC Power Cord, 16A Switzerland |
||
CAB-AC-16A-AUS AC Power Cord, 250 V, 16 A, C19 connector Australia |
||
CAB-C19-C20-3M-JP AC Power Cord C19 to C20 connector, Japan PSE mark Japan |
10 |
3 |
CAB-AC-C19-TW AC Power Cord, 250 V, 16 A, C19 connectors Taiwan |
||
CAB-AC-C6K-TWLK AC Power Cord, 250 V, 16 A, twist lock NEMA L6-20 plug US |
||
CAB-AC-2500W-EU AC Power Cord, 250 V, 16 A Europe |
||
CAB-AC-2500W-INT AC Power Cord, 250 V, 16A International |
||
CAB-9K16A-KOR AC Power Cord, 250 V, 16 A, Source Plug Korea |
||
CAB-AC-2500W-ISRL AC Power Cord, 250 V, 16 A Israel |
||
CAB-AC16A-CH AC Power Cord, 16 A China |
||
R2XX-DMYMPWRCORD No power cord; PID option for ordering node with no power cord |
NA |
NA |