The documentation set for this product strives to use bias-free language. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Exceptions may be present in the documentation due to language that is hardcoded in the user interfaces of the product software, language used based on RFP documentation, or language that is used by a referenced third-party product. Learn more about how Cisco is using Inclusive Language.
This chapter describes techniques that you can use to troubleshoot the operation of your Cisco ASR 1000 Series Modular Ethernet Line Card, and includes the following sections:
The first section provides information about basic interface troubleshooting. If you are having a problem with your Ethernet Line Card, use the steps provided in the Performing Basic Interface Troubleshooting to begin your investigation of a possible interface configuration problem.
To perform advanced troubleshooting, see the other sections in this chapter.
This section describes general information for troubleshooting the Cisco ASR 1000 Series Modular Ethernet Line Card, and includes the following subsections:
Caution | Because debugging output is assigned high priority in the CPU process, it can render the system unusable. For this reason, use debug commands only to troubleshoot specific problems, or during troubleshooting sessions with Cisco technical support staff. Moreover, it is best to use debug commands during periods of lower network traffic and fewer users. Debugging during these periods decreases the likelihood that increased debug command-processing overhead will affect system use. |
The debug hw-module subslot command is intended for use by Cisco technical support personnel.
For information about other debug commands supported on the and any related feature documents for the applicable Cisco IOS release.
There are several show commands that you can use to monitor and troubleshoot the Cisco ASR 1000 Series Modular Ethernet Line Card on the Cisco ASR 1000 Series Routers. This chapter describes using the show interfaces command to perform troubleshooting of your Ethernet Line Card.
For more information about show commands to verify and monitor Ethernet Line Cards, see Chapter 3, “Configuring the Cisco ASR 1000 Series Modular Ethernet Line Card” , and the Cisco IOS technology area command reference books.
You can perform most of the basic interface troubleshooting using the show interfaces HundredGigE command or the show interfaces tengigabitethernet command, and examining several areas of the output to determine how the interface is operating.
The following example shows an output of the show interfaces HundredGigE and show interfaces tengigabitethernet commands:
Router# show interfaces HundredGigE 1/0/0 HundredGigE1/0/0 is up, line protocol is up Hardware is EPA-1X100GE, address is 74a0.2ff9.bc80 (bia 74a0.2ff9.bc80) Internet address is 20.1.1.1/24 MTU 9216 bytes, BW 100000000 Kbit/sec, DLY 10 usec, reliability 255/255, txload 1/255, rxload 1/255 Encapsulation ARPA, loopback not set Keepalive not supported Full Duplex, 100000Mbps, link type is force-up, media type is CPAK-100G-SR10 output flow-control is on, input flow-control is on ARP type: ARPA, ARP Timeout 04:00:00 Last input never, output 04:16:23, output hang never Last clearing of "show interface" counters never Input queue: 0/375/0/0 (size/max/drops/flushes); Total output drops: 0 Queuing strategy: fifo Output queue: 0/40 (size/max) 5 minute input rate 0 bits/sec, 0 packets/sec 5 minute output rate 0 bits/sec, 0 packets/sec 0 packets input, 0 bytes, 0 no buffer Received 0 broadcasts (0 IP multicasts) 0 runts, 0 giants, 0 throttles 0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored 0 watchdog, 0 multicast, 0 pause input 0 packets output, 0 bytes, 0 underruns 0 output errors, 0 collisions, 2 interface resets 0 unknown protocol drops 0 babbles, 0 late collision, 0 deferred 0 lost carrier, 0 no carrier, 0 pause output 0 output buffer failures, 0 output buffers swapped out Router# show interfaces TenGigabitEthernet 0/0/0 TenGigabitEthernet0/0/0 is up, line protocol is up Hardware is EPA-10X10GE, address is 0c06.2a08.0000 (bia 0c06.2a08.0000) Internet address is 10.1.1.1/24 MTU 1500 bytes, BW 10000000 Kbit/sec, DLY 10 usec, reliability 255/255, txload 1/255, rxload 1/255 Encapsulation ARPA, loopback not set Keepalive not supported Full Duplex, 10000Mbps, link type is force-up, media type is SFP-SR output flow-control is on, input flow-control is on ARP type: ARPA, ARP Timeout 04:00:00 Last input 12:20:20, output 00:00:17, output hang never Last clearing of "show interface" counters never Input queue: 0/375/0/0 (size/max/drops/flushes); Total output drops: 869547364 Queuing strategy: fifo Output queue: 0/40 (size/max) 30 second input rate 0 bits/sec, 0 packets/sec 30 second output rate 0 bits/sec, 0 packets/sec 4 packets input, 240 bytes, 0 no buffer Received 3 broadcasts (0 IP multicasts) 0 runts, 0 giants, 0 throttles 0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored 0 watchdog, 0 multicast, 0 pause input 4196414314 packets output, 1497953063392 bytes, 0 underruns 0 output errors, 0 collisions, 8 interface resets 0 unknown protocol drops 0 babbles, 0 late collision, 0 deferred 0 lost carrier, 0 no carrier, 0 pause output 0 output buffer failures, 0 output buffers swapped out
To verify that your interface is operating properly, complete the steps described in table:
Action |
Example |
---|---|
From the global configuration mode, enter the show interfaces HundredGigE or the show interfaces tengigabitethernet command. |
Router# show interfaces HundredGigE 2/0/0 Router# show interfaces tengigabitethernet 1/0/0 |
Verify that the interface is up. |
Router# show interfaces HundredGigE 2/0/0 HundredGigE 2/0/0 is up , line protocol is up Router# show interfaces tengigabitethernet 0/0/0 TenGigabitEthernet0/0/0 is up, line protocol is up (connected) |
Verify that the line protocol is up. |
Router# show interfaces HundredGigE 2/0/0 HundredGigE2/0/0 is up, line protocol is up Router# show interfaces tengigabitethernet 0/0/0 TenGigabitEthernet0/0/0 is up, line protocol is up (connected) |
Observe the Cyclic Redundancy Check (CRC) counter. |
0 input errors, 0 CRC, 0 frame, 130043940 overrun, 0 ignored |
Observe the carrier signal counters. |
0 lost carrier, 0 no carrier , 0 pause output 0 output buffer failures, 0 output buffers swapped out |
For more information about the verification steps and possible responses to correct the detected problems, see the following sections:
In the output of the show interfaces HundredGigE command or the show interfaces tengigabitethernet command, verify that the interface is up. If the interface is down, perform the following corrective actions:
In the output of the show interfaces HundredGigE or the show interfaces tengigabitethernet command, verify that the line protocol is up. If the line protocol is down, then it means that the line protocol software processes have determined that the line is unusable.
Perform the following corrective actions:
In the output of the show interfaces HundredGigE and the show interfaces tengigabitethernet commands, observe the value of the CRC counter. Excessive noise will cause high CRC errors accompanied by a low number of collisions.
Perform the following corrective actions if you encounter high CRC errors:
In the output of the show interfaces HundredGigE and the show interfaces tengigabitethernet commands, observe the value of the carrier signal counters. The lost carrier counter shows the number of times that the carrier was lost during transmission. The no carrier counter shows the number of times that the carrier was not present during transmission.
Carrier signal resets can occur when an interface is in the loopback mode or shut down.
Perform the following corrective actions if you observe the carrier signal counter incrementing outside of these conditions: