This section contains the procedures for troubleshooting alarms.
RX-LOS-P
Default Severity: Critical
Logical Object: Controller
The RX-LOS-P alarm is raised when there is loss of signal.
Clear the RX-LOS-P Alarm
-
Verify the transmission (TX) at the peer end.
-
Check the fiber connections.
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447).
RX-POWER-FAIL-LOW
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
Logical Object: Controller
The RX-POWER-FAIL-LOW alarm is raised when the RX power is below the configured low threshold values.
Clear the RX-POWER-FAIL-LOW Alarm
-
Verify the transmission (TX) at the peer end.
-
Check the fiber connections.
-
Increase the peer end gain or transmit-power value to obtain the RX power above the threshold.
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447).
TX-POWER-FAIL-LOW
Default Severity: Critical
Logical Object: Controller
The TX-POWER-FAIL-LOW alarm is raised when the TX power is below the configured low threshold values.
Clear the TX-POWER-FAIL-LOW Alarm
-
Increase the gain or power configuration value to obtain the TX power above the threshold.
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447).
EGRESS-AMPLI-GAIN-LOW
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
Logical Object: Controller
The EGRESS-AMPLI-GAIN-LOW alarm is raised when the actual gain of the OLS pluggable is lower than the configured gain value.
Clear the EGRESS-AMPLI-GAIN-LOW Alarm
-
Configure the gain value within the optimum range.
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447).
EGRESS-AMPLI-GAIN-HIGH
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
Logical Object: Controller
The EGRESS-AMPLI-GAIN-HIGH alarm is raised when the actual gain of the OLS pluggable is higher than the configured gain value.
Clear the EGRESS-AMPLI-GAIN-HIGH Alarm
-
Verify the RX and TX values and adjust the gain within the optimum working range.
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447).
EGRESS-AUTO-LASER-SHUT
Default Severity: Not-Alarmed
Logical Object: Controller
The EGRESS-AUTO-LASER-SHUT alarm is raised when there is loss of signal (LOS) on the OTS line side (subport 1)
Clear the EGRESS-AUTO-LASER-SHUT Alarm
-
Verify the fiber connections on the line side of the OLS pluggable.
-
Verify the gain or power on the line side of the peer end.
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447).
EGRESS-AUTO-POW-RED
Default Severity: Not-Alarmed
Logical Object: Controller
The EGRESS-AUTO-POW-RED alarm is raised when there is loss of signal (LOS) on the OTS line side (subport 1)
Clear the EGRESS-AUTO-POW-RED Alarm
-
Verify the fiber connections on the line side of the OLS pluggable.
-
Verify the gain or power on the line side of the peer end.
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447).