Overview
Feature Name |
Release Information |
Description |
---|---|---|
NCS2K-MF-8x10G-FO | Cisco NCS 2000 Release 12.3 |
The MPO-12 to 8-LC fan-out module is a double slot module with two MPO-12 connector (COM) and eight LC duplex connectors (Port-i-TX/RX). It contains 16 photodiodes to monitor the power of the channel input ports. |
_15216-PP-4-SMR |
Cisco NCS 2000 Release 12.3 |
The _15216-PP-4-SMR patch panel connects up to four 40-SMR2-C cards in a four-degree mesh node. The optical splitters inside the patch panel forward the output signal (EXP-TX port) of the 40-SMR2-C card on each side of the mesh node to the input port of the 40-SMR2-C cards on the other three sides of the mesh node. |
NCS2K-MF-CL-SC | Cisco NCS 2000 Release 12.2 |
A new passive module, the C and L-band combiner and splitter, is introduced. The L-band addition for non-Raman assisted optical links requires a C and L optical combiner for expansion. The NCS2K-MF-CL-SC module allows Cisco to introduce any future L-band transmission system onto the existing NCS 2000 deployments. |
Passive devices are used to build the optical network system. You can install them on:
-
19 inch (482.6 mm) or 23 inch (584.2 mm) EIA standard racks
-
19 inch (482.6 mm) IEC rack
-
600 mm x 600 mm or 600 mm x 300-mm ETSI rack
The following table lists the supported passive chassis and passive devices:
Passive Chassis and Passive Devices |
Description |
SSON Package (12.xx-xxxx-xx.xx-S-SPA) |
MSTP Package (12.xx-xxxx-xx.xx-L-SPA) |
---|---|---|---|
NCS2K-MF-6RU |
You can install a combination of 14 single-slot passive devices in this chassis. |
✓ |
|
NCS2K-MF10-6RU |
You can install a combination of 10 double-slot passive devices in this chassis. |
✓ |
|
NCS2K-MF-DEG-5 |
5-degree mesh module. |
✓ |
|
NCS2K-MF-UPG-4 |
4-degree upgrade module. |
✓ |
|
NCS2K-MF-MPO-16LC |
MPO-16 to 16-LC fan-out module. |
✓ |
|
NCS2K-MF-2MPO-ADP |
Double MPO-16 to two MPO-8 adapter module. |
✓ |
|
15216-MD-48-EVEN |
Multiplexer/demultiplexer patch panels of 48-channels on the even ITU grid. |
✓ |
✓ (only as inventory) |
15216-MD-48-ODD |
Multiplexer/demultiplexer patch panels of 48-channels on the odd ITU grid. |
✓ |
✓ (only as inventory) |
15216-MD-48-CM |
Interleaver and deinterleaver pluggable that operates inside ONS 15216-MD-48 odd/even patch panels and 15216-MD-40 odd/even patch panels. |
✓ |
✓ (only as inventory) |
NCS2K-PPMESH8-5AD |
8-degree mesh patch panel module with 16 MPO-16 connectors and 10 MPO-8 connectors. |
✓ |
|
NCS2K-MF-6AD-CFS |
Six ports add/drop single slot module. It contains a 6x1 combiner and a 1x6 splitter. |
✓ |
|
NCS2K-MF-DEG-5-CV |
5-degree mesh connection verification module with MPO-8 loopback caps. |
✓ |
|
NCS2K-MF-UPG-4-CV |
4-degree upgrade connection verification module with MPO-8 loopback caps. |
✓ |
|
NCS2K-MF-MPO-8LC |
MPO-APC to eight LC-PC fan-out module. |
✓ |
|
NCS2K-MF-M16LC-CV |
MPO-16 to 16-LC fan-out connection verification double slot module based on the NCS2K-MF-MPO-16LC. It has eight LC loopback caps (NCS2K-LC-LBK=) on all LC dual ports. |
✓ |
|
NCS2K-MF-10AD-CFS |
10 port add/drop double slot module. It contains a 10x1 combiner and a 1x10 splitter. |
✓ |
|
NCS2K-MF-16AD-CFS |
16-channel colorless omnidirectional add/drop passive module. |
✓ |
|
NCS2K-MF-4X4-COFS |
4-channel colorless omnidirectional add/drop passive module. |
✓ |
The 15216-MD-48-ODD and 15216-MD-48-EVEN patch panels can be installed directly in the rack and require two Rack Units (RU). You can connect the patch panels to the NCS 2006 ECU or NCS 2015 ECU.
The NCS2K-MF passive devices can be installed in a one-Rack Unit (RU) high mechanical frame (NCS2K-MF-1RU) and can be directly connected to the NCS 2006 ECU or NCS 2015 ECU. You can also install the NCS2K-MF passive devices in the passive chassis. There are two types of passive chassis—NCS2K-MF-6RU and NCS2K-MF10-6RU. You can connect the passive chassis to the USB 3.0 port in the NCS 2006 ECU-S or NCS 2015 ECU.
Laser Radiation Emission Restrictions
The Class 1M Laser safety and warning label affixed to the passive optical modules indicate that the product should never be used or installed in an optical network with emissions higher than Class 1M.
Warning |
Class 1M laser radiation when open. Do not view directly with optical instruments. Statement 281 |
Laser Safety During Operation
Warning |
Invisible laser radiation may be emitted from disconnected fibers or connectors. Do not stare into beams or view directly with optical instruments. Statement 1051 |
Electrical Safety
The passive optical modules are optically and electrically passive and require no electrical connections. No electrostatic discharge (ESD) or other electrical safety considerations apply.