Upgrade Software

This chapter describes the software upgrade in Cisco NCS 2000 SVO and its related tasks. This chapter applies to the NCS 2000 node that is already migrated to SVO with release greater than R12.x

SVO Software Package

The software package is distributed as a single file that is downloaded to the local file system of SVO and it contains all the required packages for upgrading the system. The single file image is different depending on the SVO installation type: SVO line card (ISO image file) or SVO external server (TAR image file). The package can be downloaded by any active SVO ROADM instance running on the line card or external server.

External server TAR image consists of the following:

  • NCS 2000 software packages

  • SVO software package

  • Admin plane package

ISO line card image consists of the following:

  • NCS 2000 software packages

  • SVO software package

  • Admin plane package

  • SVO line card operating system

  • Additional packages for specific line card management


Note


You must download the software only from the ROADM SVO instance and not from the OLA, DGE or TXP SVO instances.


Workflow for Software Upgrade

The Software Manager page has four tabs which are used for upgrading the device software.


Note


The following sequence is mandatory for software upgrade.


  1. Use the Download tab to download the necessary packages. The relevant procedure is discussed at Download Software Package. The downloaded packages appear in the Software Packages tab.

  2. Use the SVO Software tab to activate the SVO package. It lists the active software versions. The relevant procedure is discussed at Activate SVO Software.

  3. Use the Device Software tab to download the NCS 2000 device software packages. The relevant procedure is discussed at Download Device Software.

  4. Use the Device Software tab to activate or revert the NCS 2000 device software packages. The relevant procedure is discussed at Activate Device Software.

Download Software Package

Use this task to download the software package on the SVO card.

Before you begin

Log into the SVO Web Interface

Procedure


Step 1

Click the hamburger icon at the top-left of the page, and select Software Manager.

Step 2

Click the Download tab.

Step 3

From the Protocol drop-down list, choose SFTP.

Step 4

Enter the remote file path of the software package in the Remote File Path field.

Step 5

Choose to enter the credentials either through User-Password or Auth-Group.

  • If you choose User-Password, enter the Username and Password in the given fields.
  • If you choose Auth-Group, choose the authentication group from the Auth Group drop-down list.

Step 6

Click Download to download the software package on the SVO card.

When the software package is successfully downloaded, the Status is updated to Download of package completed on <time and date>.

Step 7

After the download, click the Refresh icon on the Software Packages tab.

The Software Packages tab displays the list of software packages that are downloaded. The Software Packages tab lists the NCS2K, SVO, operating system, and Admin Plane packages.

The following details are displayed for the downloaded packages:

  • Software Package ID—Displays the package ID of the ISO or TAR file.

  • Software Image ID—Displays the name of the individual component that is part of the ISO or TAR file.

  • File Name—Displays the filename of the software package.

  • Version—Displays the version of the software package.

  • CRC Valid—Cyclical Redundancy Check (CRC) to perform package integrity and ensure that the package content is valid.

  • Size (in bytes)—Displays the size of the software package.

Note

 

The Software Packages tab displays up to three software packages. If the fourth software package is downloaded, it automatically overwrites the oldest package that is not in use.


Activate SVO Software

Use this task to activate the SVO software package on the SVO card.

Before you begin

Log into the SVO Web Interface

Procedure


Step 1

Click the hamburger icon at the top-left of the page, and select Software Manager.

Step 2

Click the SVO Software tab.

The following details of the SVO software are displayed:

  • —Displays the name of the SVO software that is active.

  • SW Version—Displays the SVO software version that is active.

Step 3

Click Activate.

The Software Image Activation dialog box appears.

Step 4

From the drop-down list, choose the software image to activate.

Step 5

Click Activate.

A confirmation message appears.

Step 6

Click Yes.

The SVO software activation takes around 4 minutes to complete.

After the activation is complete, your session ends and the login page appears.

Step 7

Log in using your credentials and check for the updated version of the SVO software in the SW version column.


Download Device Software

Use this task to download the device software package from the SVO card to NCS 2000 device. In R12.x, you can download the device software package to only one NCS 2000 device for each SVO instance.

Before you begin

Procedure


Step 1

Click the hamburger icon at the top-left of the page, and select Software Manager.

Step 2

Click the Device Software tab.

The following details of the software packages are displayed:

  • Device Name—Displays the name of the device where the software package is downloaded.

  • Platform—Displays the component name.

  • Working SW Version—Displays the package version that is active.

  • Protect SW Version—Displays the backup package version.

  • Status—Displays the progress of package download.

Step 3

Check the checkbox against the Device Name to download the new software.

Note

 

The Device Software tab lists the NCS2K, svo-primary, and svo-secondary devices. Only the NCS 2000 device software package can be downloaded in R12.x.

Step 4

Click Download.

The Select Software Image dialog box appears.

Step 5

From the Software Image drop-down list, select the software package.

Step 6

Click Download.

The Status field displays the progress (%) of package download. After the download, the downloaded package is indicated in the Protect SW Version column.

Note

 
If you choose to download the TNC or TNCE card for the NCS 2000 device package, the Status column displays the download progress (%) of only the active card and not the standby card. The Status field changes to downloaded only after the standby card is downloaded.

After the device software is downloaded, the USB-sync alarm is raised. The USB-sync alarm clears after 6 minutes. Click the Bell icon to see the USB-sync alarm in the Alarms tab.

Use the Abort Download option to terminate the software downloading on the selected device.

Note

 

We recommend that you limit the number of simultaneous software downloads to eight nodes.


Activate Device Software

Use this task to activate the NCS 2000 device software package in R12.x.


Note


After you have downloaded the device software, wait for the USB-sync alarm to clear. If the alarm is not cleared, the activation of the NCS 2000 device software package fails.


Before you begin

Procedure


Step 1

Click the hamburger icon at the top-left of the page, and select Software Manager.

Step 2

Click the Device Software tab.

Step 3

Choose the NCS 2000 device, and click Activate to activate the device software package on NCS 2000 device.

The downloaded package that is available in the Protect SW Version is activated to the Working SW Version.

Note

 
If you choose to activate the TNC or TNCE card for the NCS 2000 device package, the Status field displays the activation progress (%) of only the active card and not the standby card.

Note

 

Use the Revert option to revert the version of the selected device to its previous software version. The Revert option is available only for the NCS 2000 package.