Installing the Cisco VG410 Voice Gateway

This chapter provides the prerequisites and the procedure for installing the Cisco VG410 Voice Gateway in an equipment rack.

Prerequisites for the Installation

Before installing the device, read the safety warnings and gather the required tools and equipment. For more information about the required tools and equipment, see the Tools and Equipment section in this hardware installation guide.

Safety Recommendations


Note


Statement 407—Japanese Safety Instruction

You are strongly advised to read the safety instruction before using the product.

https://www.cisco.com/web/JP/techdoc/pldoc/pldoc.html

When installing the product, use the provided or designated connection cables/power cables/AC adapters.



Warning


Statement 1024—Ground Conductor

This equipment must be grounded. To reduce the risk of electric shock, never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available.



Warning


Statement 1046—Installing or Replacing the Unit

To reduce risk of electric shock, when installing or replacing the unit, the ground connection must always be made first and disconnected last.

If your unit has modules, secure them with the provided screws.



Warning


Statement 338—Prevent Accidental Discharge

To prevent accidental discharge in the event of a power line cross, route on-premise wiring away from power cables and off-premise wiring, or use a grounded shield to separate the on-premise wiring from the power cables and off-premise wiring. A power line cross is an event, such as a lightning strike, that causes a power surge. Off-premise wiring is designed to withstand power line crosses. On-premise wiring is protected from power line crosses by a device that provides overcurrent and overvoltage protection. Nevertheless, if the on-premise wiring is in close proximity to or not shielded from, the off-premise wiring or power cable during a lightning strike or power surge, the on-premise wiring can carry a dangerous discharge to the attached interface, equipment, or nearby personnel.


Unpack the Device

Do not unpack the device until you are ready to install it. If the final installation site will not be ready for some time, keep the chassis in its shipping container to prevent accidental damage. When you are ready to install the chassis, proceed with unpacking it.

The chassis, accessory kit, publications, and any optional equipment you ordered may be shipped in more than one container. When you unpack the containers, check the packing list to ensure that you received all of the items on the list.

If anything appears damaged, or if you encounter problems when installing or configuring your system, contact a customer service representative.

Mounting the Voice Gateway in Rack

You can install the Cisco VG410 Voice Gateway in 19-inch (48.26-cm) Electronic Industries Alliance (EIA) racks. You can also mount the voice gateway in a 600-mm ETSI rack. You can mount the voice gateway in the following ways:

  • Front mounting: Brackets attached at the front of the chassis with the front panel facing forward. Brackets can be attached so that mounting surface can be co-planar with the front of the chassis or recessed 1.0".

  • Back mounting: Brackets attached at the back of the chassis (PSU and fanside) with the back panel facing forward.

  • Mid-mount: By reversing the orientation of the brackets, mid-mounting of the chassis can be achieved with either orientation.

Perform the following steps to mount the device on the rack:

Procedure


Step 1

Attach the mounting brackets to the chassis as shown in the following images, using the screws provided.

Caution

 

Do not over-torque the screws. The recommended torque is 15 to 18 inch-lb (1.7 to 2.0 N-m)

Figure 1. Attach the Mounting Brackets

Step 2

Attach the second bracket to the opposite side of the chassis. Use a number-2 Phillips screwdriver to install the number-6 bracket screws.

Attention

 

Your chassis installation must allow unrestricted airflow for chassis cooling.

Step 3

Use the screws provided with the rack to install the chassis in the rack. For the 19-inch EIA brackets, start the lower pair of screws first, and rest the brackets on the lower screws while you insert the upper pair of screws.

See the following images that show the mounting positions from the I/O side, mid mount, and from the power socket side, respectively.

Figure 2. I/O Side Mounting
Figure 3. Mid mounting
Figure 4. Power Socket Side Mounting

The screw slots in the brackets are spaced to line up with every second pair of screw holes in the rack. When the correct screw holes are used, the small threaded holes in the brackets line up with unused screw holes in the rack. If the small holes do not line up with the rack holes, you must raise or lower the brackets to the next rack hole. See the following image that shows a front mounted orientation in rack, for more clarity.

Figure 5. Front Mounted in Rack

Warning

 

Statement 1006—Chassis Warning for Rack-Mounting and Servicing

To prevent bodily injury when mounting or servicing this unit in a rack, you must take special precautions to ensure that the system remains stable. The following guidelines are provided to ensure your safety:

  • This unit should be mounted at the bottom of the rack if it is the only unit in the rack.

  • When mounting this unit in a partially filled rack, load the rack from the bottom to the top with the heaviest component at the bottom of the rack.

  • If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing the unit in the rack.

Warning

 

Statement 1047—Overheating Prevention

To reduce the risk of fire or bodily injury, do not operate the unit in an area that exceeds the maximum recommended ambient temperature of: 40 degrees C.


Setting the Chassis on a Desktop

After unpacking your device, you can place it on a desktop, bench top, or a shelf. However, be aware of the following before you set your chassis on a desktop:

  • Do not place anything on top of the router that weighs more than 10 pounds (4.5 kg), and do not stack the gateway hardware on a desktop. Excessive distributed weight of more than 10 pounds, or pound point load of 10 pounds on top could damage the chassis.

  • To prevent airflow restriction, allow clearance around the ventilation openings to be at least 1 inch (2.54cms). Statement 1076.

  • After you install the voice gateway, you must connect the chassis to a reliable earth ground.

The following images indicate the location of the feet for the chassis and the application of the foot.

Figure 6. Location of the Feet

Here, 1 indicates the position of the feet.

Figure 7. Application of the Foot

Chassis Grounding

Before you connect the power or turn on the power to your chassis, you must provide an adequate chassis ground (earth) connection for the chassis. To install the ground connection for your router, perform the following steps:

Before you begin

After you install the voice gateway, you must connect the chassis to a reliable earth ground. You must install the ground wire in accordance with local electrical safety standards.

You will need the following tools and supplies to connect the system ground to the chassis:

  • A size 10 AWG (4 mm2) or larger copper wire

  • An appropriate user-supplied ring terminal with an inner diameter of 1/4 in. (5–7 mm).

  • A Philips screwdriver

Procedure


Step 1

Use the wire stripper to strip one end of the ground wire to the required length for the ground lug or terminal.

  • For the ground lug, you’d require approximately 0.75 inch (20 mm)

  • For user-provided ring terminal, use length as required

Step 2

Insert the wire into the open end of the grounding lug.

Step 3

Use the crimping tool to carefully crimp the wire receptacle around the wire. This step is required to ensure a proper mechanical connection.

Step 4

Locate the chassis ground connector on the side of your chassis.

Step 5

Insert the two screws through the holes in the grounding lug. Use the two screws with captive locking washers provided.

Step 6

Use the Number 2 Phillips screwdriver to carefully tighten the screws until the grounding lug is held firmly to the chassis. Do not over tighten the screws.

Step 7

Connect the opposite end of the grounding wire to the appropriate grounding point at your site to ensure an adequate chassis ground.

Figure 8. Chassis Grounding