Technical Specifications

Router Specifications

Table 1. Cisco Catalyst IR8340 Rugged Series Router Specifications

Environmental Ranges

Operating temperature

-40°C to +60°C

Storage temperature

–40 to 185°F (–40 to 85°C)

Relative humidity

5 to 95% (noncondensing)

Operating altitude

Up to 10,000 ft (3048 m)

Physical Specifications

Weight

Weight with 1 power supply (no modules): 24 lbs (10.9 kg)

Typical weight fully configured with 2 power supplies 4 modules, timing module: 28 lb (12.7 kg)

Dimensions (H x W x D)

3.5 x 17.25 x 15 in. (88.9 x 438.2 x 381 mm)

Table 2. Cisco IR8340 Router Power Requirements

Power Requirements

Nominal input voltage

PWR-RGD-AC-DC:

100 to 240 VAC, 50 to 60 Hz,

100 to 250 VDC

PWR-RGD-AC-DC-250:

100 to 240 VAC, 50 to 60 Hz,

100 to 250 VDC

PWR-RGD-LOW-DC:

24 to 60 VDC

Table 3. Power Consumption

Description

Specification

System power consumption (with no modules and POE)

Typical : 60W, Max : 86W

T1/E1 NIM power consumption

Typical : 6W, Max : 7W

RS232 NIM Power consumption

Typical : 6W, Max : 7W

Power-Supply Module Specifications

Table 4. Power Supply Module Specifications
Model

Weight

Dimensions (H x W x D)

PWR-RGD-AC-DC

2.55 lb (1.15 kg)

1.58 x 7 x 5 in. (4 x 17.8 x 12.7 cm) (without mounting flanges)

PWR-RGD-LOW-DC

2.5 lb (1.13 kg)

1.58 x 7 x 5 in. (4 x 17.8 x 12.7 cm) (without mounting flanges)

PWR-RGD-LOW-DC-250

3.2 lb (1.45 kg)

1.58 x 7x 6.18 in. (4 x 17.8 x 15.7 cm) (with mounting flanges)

Alarm Ratings

Table 5. Alarm Input and Output Ratings

Alarm Ratings

Alarm input electrical specification

No external voltage needed to activate alarm inputs. The open circuit voltage between any Alarm input (1 to 2) and Alarm input Common is 5VDC and the loop current is 2 mA max per input.

Alarm output electrical specification

30VDC @ 1A, 48VDC @ 0.5A

Thermal Mitigation

The following tables provide a description of thermal mitigation levels and throughput performance across all IoT industrial routers.

This applies to both the 4G LTE and 5G NR FR1 operation of the P-5GS6-GL.

Table 6. Thermal Mitigation Levels

Level

Description

Level 0

Normal mode, no thermal throttling.

Level 1

Uplink throttling, via reduced UL TX duty cycle.

Level 2

May include the following:

  • DL throughput capability reduction, such as 4 RX > 2 RX paths.

  • Drop Secondary Cells (SCells) all, or one by one.

  • 5G NR > 4G LTE fall back.

  • MTPL backoff or reduced TX power.

  • Reduced UL communication range.

Level 3

Limited service.

Note

 
Limited service typically means emergency calls only. The P-5GS6-GL does not support emergency call mode, therefore limited service means “no service” for the P-5GS6-GL .

Thermal Shutdown

This occurs after Level 3.


Note


Cisco does not recommend operation deep into level 2 as this may affect communication range via MTPL backoff.
Table 7. Thermal Mitigation Table for P-LTEA7-XX modules – IR8340

Hardware

Maximum Ambient Temperature (C/F)

Airflow (LFM)

Throughput Performance

IR8340

Single P-LTEA7-XX

Single P-5GS6-GL

55℃/131℉

0

Normal

60℃/140℉

0

Throttled

Table 8. Thermal Mitigation Table for P-5GS6-R16SA-GL modules – IR8340

Hardware

Maximum Ambient Temperature (C/F)

Airflow (LFM)

Throughput Performance

IR8340

Single P-5GS6-R16SA-GL

Single P-5GS6-GL

55℃/131℉

0

Normal

60℃/140℉

0

Throttled