Monitoring the T3 or E3 Interface Module

This chapter provides information on monitoring the T3 or E3 interface module. Some of monitoring tools available are:

  • Maintenance Data Link (MDL) messages

  • Perfomance Monitoring

MDL Messages

MDL messages are used to communicate identification information between local and remote ports. The MDL message includes:

  • Equipment Identification Code (EIC)

  • Location Identification Code (LIC)

  • Frame Identification Code (FIC)

  • Unit

  • Path Facility Identification (PFI)

  • Port Number

  • Generator Identification Number


Note


MDL messages are only supported when the T3 framing is set for C-bit parity.


The no mdl command removes the configuration of mdl messages.


Note


MDL configuration is not supported for E3 interfaces.


Configuring MDL for Path Transmission

To configure MDL path transmission messages on T3 controller configuration mode, use the following commands:
 
enable
configure terminal
controller t3 0/0/17
framing c-bit
mdl string eic beic
mdl  string lic beic
mdl  string fic bfix
mdl  string unit bunit
mdl  string pfi bpfi
mdl  transmit path

Verifying MDL for Path Transmission Configuration

For PE1 Configuration:

Use the show controller command to display the verification of MDL path transmission configuration.


Router# show controllers t3 0/0/17

T3 0/0/17 is up.
  Hardware is ASR903-48T3E3-CE

  Applique type is Channelized T3
  No alarms detected.
  MDL transmission is disabled
    
  FEAC code received: No code is being received
  Framing is C-BIT Parity, Line Code is B3ZS, Cablelength Short less than 225ft
  BER thresholds:  SF = 10e-10  SD = 10e-10
  Clock Source is internal
  Equipment customer loopback
  Data in current interval (240 seconds elapsed):                              
   Near End                                                                    
     0 Line Code Violations, 0 P-bit Coding Violations                         
     0 C-bit Coding Violations, 0 P-bit Err Secs                               
     0 P-bit Severely Err Secs, 0 Severely Err Framing Secs                    
     0 Unavailable Secs, 0 Line Errored Secs                                   
     0 C-bit Errored Secs, 0 C-bit Severely Errored Secs                       
     0 Severely Errored Line Secs, 0 Path Failures                             
     0 AIS Defect Secs, 0 LOS Defect Secs                                      
   Far End                                                                     
     0 Errored Secs, 0 Severely Errored Secs                                   
     0 C-bit Unavailable Secs, 0 Path Failures                                 
     0 Code Violations, 0 Service Affecting Secs                               
  Data in Interval 1:                                                          
   Near End                                                                    
     0 Line Code Violations, 0 P-bit Coding Violations                         
     0 C-bit Coding Violations, 0 P-bit Err Secs                               
     0 P-bit Severely Err Secs, 0 Severely Err Framing Secs                    
     20 Unavailable Secs, 20 Line Errored Secs                                 
     0 C-bit Errored Secs, 0 C-bit Severely Errored Secs                       
     20 Severely Errored Line Secs, 1 Path Failures                            
     0 AIS Defect Secs, 20 LOS Defect Secs                                     
   Far End                                                                     
     0 Errored Secs, 0 Severely Errored Secs                                   
     0 C-bit Unavailable Secs, 0 Path Failures                                 
     0 Code Violations, 0 Service Affecting Secs                               
  Total Data (last 1 15 minute intervals):                                     
   Near End                                                                    
     0 Line Code Violations, 0 P-bit Coding Violations,                        
     0 C-bit Coding Violations, 0 P-bit Err Secs,                              
     0 P-bit Severely Err Secs, 0 Severely Err Framing Secs,                   
     20 Unavailable Secs, 20 Line Errored Secs,                                
     0 C-bit Errored Secs, 0 C-bit Severely Errored Secs                       
     20 Severely Errored Line Secs, 1 path failures                            
     0 AIS Defect Secs, 20 LOS Defect Secs                                     
   Far End                                                                     
     0 Errored Secs, 0 Severely Errored Secs                                   
     0 C-bit Unavailable Secs, 0 Path Failures                                 
     0 Code Violations, 0 Service Affecting Secs 

T1 1 is up
  timeslots: 
  FDL per AT&T 54016 spec.
  No alarms detected.     
  Framing is ESF, Clock Source is Internal
  Data in current interval (250 seconds elapsed):
   Near End                                      
     0 Line Code Violations, 0 Path Code Violations
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs       
     0 Unavailable Secs, 0 Stuffed Secs                           
     0 Path Failures, 0 SEF/AIS Secs                              
   Far End                                                        
     0 Line Code Violations, 0 Path Code Violations               
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs       
     0 Unavailable Secs 0 Path Failures                           
  Data in Interval 1:                                             
   Near End                                                       
     0 Line Code Violations, 0 Path Code Violations               
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     2 Errored Secs, 0 Bursty Err Secs, 2 Severely Err Secs       
     0 Unavailable Secs, 0 Stuffed Secs                           
     1 Path Failures, 2 SEF/AIS Secs                              
   Far End                                                        
     0 Line Code Violations, 0 Path Code Violations               
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     3 Errored Secs, 0 Bursty Err Secs, 3 Severely Err Secs       
     0 Unavailable Secs 0 Path Failures                           
  Total Data (last 1 15 minute intervals):                        
   Near End                                                       
     0 Line Code Violations,0 Path Code Violations,               
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,
     2 Errored Secs, 0 Bursty Err Secs, 2 Severely Err Secs        
     0 Unavailable Secs, 0 Stuffed Secs                            
     1 Path Failures, 2 SEF/AIS Secs                               
   Far End                                                         
     0 Line Code Violations,0 Path Code Violations                 
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,
     3 Errored Secs, 0 Bursty Err Secs, 3 Severely Err Secs        
     0 Unavailable Secs, 0 Path Failures 

For PE2 Configuration:

Use the show controller command to display the verification of MDL path transmission configuration.


Router# show controllers t3 0/0/18

T3 0/0/18 is up.
  Hardware is ASR903-48T3E3-CE

Applique type is Channelized T3
  No alarms detected.
  MDL transmission is enabled
    
  Far-End MDL Information Received
     EIC: beic, LIC: beic, FIC: bfix, UNIT: bunit
     Idle Signal PORT_NO: bport
  FEAC code received: DS3 Out-Of-Frame
  Framing is C-BIT Parity, Line Code is B3ZS, Cablelength Short less than 225ft
  Clock Source is internal
  Equipment customer loopback

  Data in current interval (240 seconds elapsed):                              
   Near End                                                                    
     0 Line Code Violations, 0 P-bit Coding Violations                         
     0 C-bit Coding Violations, 0 P-bit Err Secs                               
     0 P-bit Severely Err Secs, 0 Severely Err Framing Secs                    
     0 Unavailable Secs, 0 Line Errored Secs                                   
     0 C-bit Errored Secs, 0 C-bit Severely Errored Secs                       
     0 Severely Errored Line Secs, 0 Path Failures                             
     0 AIS Defect Secs, 0 LOS Defect Secs                                      
   Far End                                                                     
     0 Errored Secs, 0 Severely Errored Secs                                   
     0 C-bit Unavailable Secs, 0 Path Failures                                 
     0 Code Violations, 0 Service Affecting Secs                               
  Data in Interval 1:                                                          
   Near End                                                                    
     0 Line Code Violations, 0 P-bit Coding Violations                         
     0 C-bit Coding Violations, 0 P-bit Err Secs                               
     0 P-bit Severely Err Secs, 0 Severely Err Framing Secs                    
     20 Unavailable Secs, 20 Line Errored Secs                                 
     0 C-bit Errored Secs, 0 C-bit Severely Errored Secs                       
     20 Severely Errored Line Secs, 1 Path Failures                            
     0 AIS Defect Secs, 20 LOS Defect Secs                                     
   Far End                                                                     
     0 Errored Secs, 0 Severely Errored Secs                                   
     0 C-bit Unavailable Secs, 0 Path Failures                                 
     0 Code Violations, 0 Service Affecting Secs                               
  Total Data (last 1 15 minute intervals):                                     
   Near End                                                                    
     0 Line Code Violations, 0 P-bit Coding Violations,                        
     0 C-bit Coding Violations, 0 P-bit Err Secs,                              
     0 P-bit Severely Err Secs, 0 Severely Err Framing Secs,                   
     20 Unavailable Secs, 20 Line Errored Secs,                                
     0 C-bit Errored Secs, 0 C-bit Severely Errored Secs                       
     20 Severely Errored Line Secs, 1 path failures                            
     0 AIS Defect Secs, 20 LOS Defect Secs                                     
   Far End                                                                     
     0 Errored Secs, 0 Severely Errored Secs                                   
     0 C-bit Unavailable Secs, 0 Path Failures                                 
     0 Code Violations, 0 Service Affecting Secs 

T1 1 is up
  timeslots: 
  FDL per AT&T 54016 spec.
  No alarms detected.     
  Framing is ESF, Clock Source is Internal
  Data in current interval (250 seconds elapsed):
   Near End                                      
     0 Line Code Violations, 0 Path Code Violations
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs       
     0 Unavailable Secs, 0 Stuffed Secs                           
     0 Path Failures, 0 SEF/AIS Secs                              
   Far End                                                        
     0 Line Code Violations, 0 Path Code Violations               
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs       
     0 Unavailable Secs 0 Path Failures                           
  Data in Interval 1:                                             
   Near End                                                       
     0 Line Code Violations, 0 Path Code Violations               
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     2 Errored Secs, 0 Bursty Err Secs, 2 Severely Err Secs       
     0 Unavailable Secs, 0 Stuffed Secs                           
     1 Path Failures, 2 SEF/AIS Secs                              
   Far End                                                        
     0 Line Code Violations, 0 Path Code Violations               
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     3 Errored Secs, 0 Bursty Err Secs, 3 Severely Err Secs       
     0 Unavailable Secs 0 Path Failures                           
  Total Data (last 1 15 minute intervals):                        
   Near End                                                       
     0 Line Code Violations,0 Path Code Violations,               
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,
     2 Errored Secs, 0 Bursty Err Secs, 2 Severely Err Secs        
     0 Unavailable Secs, 0 Stuffed Secs                            
     1 Path Failures, 2 SEF/AIS Secs                               
   Far End                                                         
     0 Line Code Violations,0 Path Code Violations                 
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,
     3 Errored Secs, 0 Bursty Err Secs, 3 Severely Err Secs        
     0 Unavailable Secs, 0 Path Failures 

Configuring MDL for Test Signal

To configure MDL test signal messages on T3 controller configuration mode, use the following commands:
 
enable
configure terminal
controller t3 0/0/17
framing c-bit
mdl string eic beic
mdl string lic beic
mdl string fic bfix
mdl string unit bunit
mdl string generator bgen
mdl transmit test-signal

Verifying MDL for Test Signal Configuration

For PE1 Configuration:

Use the show controller command to display the verification of MDL for test signal configuration.


Router# show controllers t3 0/0/17
T3 0/0/17 is up.
  Hardware is ASR903-48T3E3-CE

  Applique type is Channelized T3
  No alarms detected.
  MDL transmission is enabled
     EIC: beic, LIC: beic, FIC: bfix, UNIT: bunit
     Test Signal GEN_NO: bgen
  FEAC code received: DS3 Out-Of-Frame
  Framing is C-BIT Parity, Line Code is B3ZS, Cablelength Short less than 225ft
  Clock Source is internal
  Equipment customer loopback
  Data in current interval (240 seconds elapsed):                              
   Near End                                                                    
     0 Line Code Violations, 0 P-bit Coding Violations                         
     0 C-bit Coding Violations, 0 P-bit Err Secs                               
     0 P-bit Severely Err Secs, 0 Severely Err Framing Secs                    
     0 Unavailable Secs, 0 Line Errored Secs                                   
     0 C-bit Errored Secs, 0 C-bit Severely Errored Secs                       
     0 Severely Errored Line Secs, 0 Path Failures                             
     0 AIS Defect Secs, 0 LOS Defect Secs                                      
   Far End                                                                     
     0 Errored Secs, 0 Severely Errored Secs                                   
     0 C-bit Unavailable Secs, 0 Path Failures                                 
     0 Code Violations, 0 Service Affecting Secs                               
  Data in Interval 1:                                                          
   Near End                                                                    
     0 Line Code Violations, 0 P-bit Coding Violations                         
     0 C-bit Coding Violations, 0 P-bit Err Secs                               
     0 P-bit Severely Err Secs, 0 Severely Err Framing Secs                    
     20 Unavailable Secs, 20 Line Errored Secs                                 
     0 C-bit Errored Secs, 0 C-bit Severely Errored Secs                       
     20 Severely Errored Line Secs, 1 Path Failures                            
     0 AIS Defect Secs, 20 LOS Defect Secs                                     
   Far End                                                                     
     0 Errored Secs, 0 Severely Errored Secs                                   
     0 C-bit Unavailable Secs, 0 Path Failures                                 
     0 Code Violations, 0 Service Affecting Secs                               
  Total Data (last 1 15 minute intervals):                                     
   Near End                                                                    
     0 Line Code Violations, 0 P-bit Coding Violations,                        
     0 C-bit Coding Violations, 0 P-bit Err Secs,                              
     0 P-bit Severely Err Secs, 0 Severely Err Framing Secs,                   
     20 Unavailable Secs, 20 Line Errored Secs,                                
     0 C-bit Errored Secs, 0 C-bit Severely Errored Secs                       
     20 Severely Errored Line Secs, 1 path failures                            
     0 AIS Defect Secs, 20 LOS Defect Secs                                     
   Far End                                                                     
     0 Errored Secs, 0 Severely Errored Secs                                   
     0 C-bit Unavailable Secs, 0 Path Failures                                 
     0 Code Violations, 0 Service Affecting Secs

T1 1 is up
  timeslots: 
  FDL per AT&T 54016 spec.
  No alarms detected.     
  Framing is ESF, Clock Source is Internal
  Data in current interval (250 seconds elapsed):
   Near End                                      
     0 Line Code Violations, 0 Path Code Violations
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs       
     0 Unavailable Secs, 0 Stuffed Secs                           
     0 Path Failures, 0 SEF/AIS Secs                              
   Far End                                                        
     0 Line Code Violations, 0 Path Code Violations               
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs       
     0 Unavailable Secs 0 Path Failures                           
  Data in Interval 1:                                             
   Near End                                                       
     0 Line Code Violations, 0 Path Code Violations               
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     2 Errored Secs, 0 Bursty Err Secs, 2 Severely Err Secs       
     0 Unavailable Secs, 0 Stuffed Secs                           
     1 Path Failures, 2 SEF/AIS Secs                              
   Far End                                                        
     0 Line Code Violations, 0 Path Code Violations               
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     3 Errored Secs, 0 Bursty Err Secs, 3 Severely Err Secs       
     0 Unavailable Secs 0 Path Failures                           
  Total Data (last 1 15 minute intervals):                        
   Near End                                                       
     0 Line Code Violations,0 Path Code Violations,               
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,
     2 Errored Secs, 0 Bursty Err Secs, 2 Severely Err Secs        
     0 Unavailable Secs, 0 Stuffed Secs                            
     1 Path Failures, 2 SEF/AIS Secs                               
   Far End                                                         
     0 Line Code Violations,0 Path Code Violations                 
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,
     3 Errored Secs, 0 Bursty Err Secs, 3 Severely Err Secs        
     0 Unavailable Secs, 0 Path Failures 

For PE2 Configuration:

Use the show controller command to display the verification of MDL for test signal configuration.


Router#  show controllers t3 0/0/18
T3 0/0/18 is up.
  Hardware is ASR903-48T3E3-CE

  Applique type is Channelized T3
  No alarms detected.
  MDL transmission is disabled
    
  Far-End MDL Information Received
     EIC: beic, LIC: beic, FIC: bfix, UNIT: bunit
     Test Signal GEN_NO: bgen
  FEAC code received: DS3 Out-Of-Frame
  Framing is C-BIT Parity, Line Code is B3ZS, Cablelength Short less than 225ft
  Clock Source is internal
  Equipment customer loopback
  Data in current interval (240 seconds elapsed):                              
   Near End                                                                    
     0 Line Code Violations, 0 P-bit Coding Violations                         
     0 C-bit Coding Violations, 0 P-bit Err Secs                               
     0 P-bit Severely Err Secs, 0 Severely Err Framing Secs                    
     0 Unavailable Secs, 0 Line Errored Secs                                   
     0 C-bit Errored Secs, 0 C-bit Severely Errored Secs                       
     0 Severely Errored Line Secs, 0 Path Failures                             
     0 AIS Defect Secs, 0 LOS Defect Secs                                      
   Far End                                                                     
     0 Errored Secs, 0 Severely Errored Secs                                   
     0 C-bit Unavailable Secs, 0 Path Failures                                 
     0 Code Violations, 0 Service Affecting Secs                               
  Data in Interval 1:                                                          
   Near End                                                                    
     0 Line Code Violations, 0 P-bit Coding Violations                         
     0 C-bit Coding Violations, 0 P-bit Err Secs                               
     0 P-bit Severely Err Secs, 0 Severely Err Framing Secs                    
     20 Unavailable Secs, 20 Line Errored Secs                                 
     0 C-bit Errored Secs, 0 C-bit Severely Errored Secs                       
     20 Severely Errored Line Secs, 1 Path Failures                            
     0 AIS Defect Secs, 20 LOS Defect Secs                                     
   Far End                                                                     
     0 Errored Secs, 0 Severely Errored Secs                                   
     0 C-bit Unavailable Secs, 0 Path Failures                                 
     0 Code Violations, 0 Service Affecting Secs                               
  Total Data (last 1 15 minute intervals):                                     
   Near End                                                                    
     0 Line Code Violations, 0 P-bit Coding Violations,                        
     0 C-bit Coding Violations, 0 P-bit Err Secs,                              
     0 P-bit Severely Err Secs, 0 Severely Err Framing Secs,                   
     20 Unavailable Secs, 20 Line Errored Secs,                                
     0 C-bit Errored Secs, 0 C-bit Severely Errored Secs                       
     20 Severely Errored Line Secs, 1 path failures                            
     0 AIS Defect Secs, 20 LOS Defect Secs                                     
   Far End                                                                     
     0 Errored Secs, 0 Severely Errored Secs                                   
     0 C-bit Unavailable Secs, 0 Path Failures                                 
     0 Code Violations, 0 Service Affecting Secs

T1 1 is up
  timeslots: 
  FDL per AT&T 54016 spec.
  No alarms detected.     
  Framing is ESF, Clock Source is Internal
  Data in current interval (250 seconds elapsed):
   Near End                                      
     0 Line Code Violations, 0 Path Code Violations
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs       
     0 Unavailable Secs, 0 Stuffed Secs                           
     0 Path Failures, 0 SEF/AIS Secs                              
   Far End                                                        
     0 Line Code Violations, 0 Path Code Violations               
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs       
     0 Unavailable Secs 0 Path Failures                           
  Data in Interval 1:                                             
   Near End                                                       
     0 Line Code Violations, 0 Path Code Violations               
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     2 Errored Secs, 0 Bursty Err Secs, 2 Severely Err Secs       
     0 Unavailable Secs, 0 Stuffed Secs                           
     1 Path Failures, 2 SEF/AIS Secs                              
   Far End                                                        
     0 Line Code Violations, 0 Path Code Violations               
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     3 Errored Secs, 0 Bursty Err Secs, 3 Severely Err Secs       
     0 Unavailable Secs 0 Path Failures                           
  Total Data (last 1 15 minute intervals):                        
   Near End                                                       
     0 Line Code Violations,0 Path Code Violations,               
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,
     2 Errored Secs, 0 Bursty Err Secs, 2 Severely Err Secs        
     0 Unavailable Secs, 0 Stuffed Secs                            
     1 Path Failures, 2 SEF/AIS Secs                               
   Far End                                                         
     0 Line Code Violations,0 Path Code Violations                 
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,
     3 Errored Secs, 0 Bursty Err Secs, 3 Severely Err Secs        
     0 Unavailable Secs, 0 Path Failures 

Configuring MDL for Idle Signal

To configure MDL idle signal messages on T3 controller configuration mode, use the following commands:

enable
configure terminal
controller T3 0/0/17
framing c-bit
mdl string eic beic
mdl string lic beic
mdl string fic bfix
mdl string unit bunit
mdl string port bport
mdl transmit idle-signal

Verifying MDL for Idle Signal Configuration

For PE1 Configuration:

Use the show controller command to display the verification of MDL for idle signal configuration.


Router# show controllers t3 0/0/17

T3 0/0/17 is up.
  Hardware is ASR903-48T3E3-CE

  Applique type is Channelized T3
  No alarms detected.
  MDL transmission is disabled
    
  FEAC code received: No code is being received
  Framing is C-BIT Parity, Line Code is B3ZS, Cablelength Short less than 225ft
  BER thresholds:  SF = 10e-10  SD = 10e-10
  Clock Source is internal
  Equipment customer loopback
  Data in current interval (240 seconds elapsed):                              
   Near End                                                                    
     0 Line Code Violations, 0 P-bit Coding Violations                         
     0 C-bit Coding Violations, 0 P-bit Err Secs                               
     0 P-bit Severely Err Secs, 0 Severely Err Framing Secs                    
     0 Unavailable Secs, 0 Line Errored Secs                                   
     0 C-bit Errored Secs, 0 C-bit Severely Errored Secs                       
     0 Severely Errored Line Secs, 0 Path Failures                             
     0 AIS Defect Secs, 0 LOS Defect Secs                                      
   Far End                                                                     
     0 Errored Secs, 0 Severely Errored Secs                                   
     0 C-bit Unavailable Secs, 0 Path Failures                                 
     0 Code Violations, 0 Service Affecting Secs                               
  Data in Interval 1:                                                          
   Near End                                                                    
     0 Line Code Violations, 0 P-bit Coding Violations                         
     0 C-bit Coding Violations, 0 P-bit Err Secs                               
     0 P-bit Severely Err Secs, 0 Severely Err Framing Secs                    
     20 Unavailable Secs, 20 Line Errored Secs                                 
     0 C-bit Errored Secs, 0 C-bit Severely Errored Secs                       
     20 Severely Errored Line Secs, 1 Path Failures                            
     0 AIS Defect Secs, 20 LOS Defect Secs                                     
   Far End                                                                     
     0 Errored Secs, 0 Severely Errored Secs                                   
     0 C-bit Unavailable Secs, 0 Path Failures                                 
     0 Code Violations, 0 Service Affecting Secs                               
  Total Data (last 1 15 minute intervals):                                     
   Near End                                                                    
     0 Line Code Violations, 0 P-bit Coding Violations,                        
     0 C-bit Coding Violations, 0 P-bit Err Secs,                              
     0 P-bit Severely Err Secs, 0 Severely Err Framing Secs,                   
     20 Unavailable Secs, 20 Line Errored Secs,                                
     0 C-bit Errored Secs, 0 C-bit Severely Errored Secs                       
     20 Severely Errored Line Secs, 1 path failures                            
     0 AIS Defect Secs, 20 LOS Defect Secs                                     
   Far End                                                                     
     0 Errored Secs, 0 Severely Errored Secs                                   
     0 C-bit Unavailable Secs, 0 Path Failures                                 
     0 Code Violations, 0 Service Affecting Secs 

T1 1 is up
  timeslots: 
  FDL per AT&T 54016 spec.
  No alarms detected.     
  Framing is ESF, Clock Source is Internal
  Data in current interval (250 seconds elapsed):
   Near End                                      
     0 Line Code Violations, 0 Path Code Violations
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs       
     0 Unavailable Secs, 0 Stuffed Secs                           
     0 Path Failures, 0 SEF/AIS Secs                              
   Far End                                                        
     0 Line Code Violations, 0 Path Code Violations               
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs       
     0 Unavailable Secs 0 Path Failures                           
  Data in Interval 1:                                             
   Near End                                                       
     0 Line Code Violations, 0 Path Code Violations               
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     2 Errored Secs, 0 Bursty Err Secs, 2 Severely Err Secs       
     0 Unavailable Secs, 0 Stuffed Secs                           
     1 Path Failures, 2 SEF/AIS Secs                              
   Far End                                                        
     0 Line Code Violations, 0 Path Code Violations               
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     3 Errored Secs, 0 Bursty Err Secs, 3 Severely Err Secs       
     0 Unavailable Secs 0 Path Failures                           
  Total Data (last 1 15 minute intervals):                        
   Near End                                                       
     0 Line Code Violations,0 Path Code Violations,               
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,
     2 Errored Secs, 0 Bursty Err Secs, 2 Severely Err Secs        
     0 Unavailable Secs, 0 Stuffed Secs                            
     1 Path Failures, 2 SEF/AIS Secs                               
   Far End                                                         
     0 Line Code Violations,0 Path Code Violations                 
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,
     3 Errored Secs, 0 Bursty Err Secs, 3 Severely Err Secs        
     0 Unavailable Secs, 0 Path Failures 

For PE2 Configuration:

Use the show controller command to display the verification of MDL for idle signal configuration.


Router# show controllers t3 0/0/18

T3 0/0/18 is up.
  Hardware is ASR903-48T3E3-CE

  Applique type is Channelized T3
  No alarms detected.
  MDL transmission is enabled
    
  Far-End MDL Information Received
     EIC: beic, LIC: beic, FIC: bfix, UNIT: bunit
     Idle Signal PORT_NO: bport
  FEAC code received: DS3 Out-Of-Frame
  Framing is C-BIT Parity, Line Code is B3ZS, Cablelength Short less than 225ft
  Clock Source is internal
  Equipment customer loopback

  Data in current interval (240 seconds elapsed):                              
   Near End                                                                    
     0 Line Code Violations, 0 P-bit Coding Violations                         
     0 C-bit Coding Violations, 0 P-bit Err Secs                               
     0 P-bit Severely Err Secs, 0 Severely Err Framing Secs                    
     0 Unavailable Secs, 0 Line Errored Secs                                   
     0 C-bit Errored Secs, 0 C-bit Severely Errored Secs                       
     0 Severely Errored Line Secs, 0 Path Failures                             
     0 AIS Defect Secs, 0 LOS Defect Secs                                      
   Far End                                                                     
     0 Errored Secs, 0 Severely Errored Secs                                   
     0 C-bit Unavailable Secs, 0 Path Failures                                 
     0 Code Violations, 0 Service Affecting Secs                               
  Data in Interval 1:                                                          
   Near End                                                                    
     0 Line Code Violations, 0 P-bit Coding Violations                         
     0 C-bit Coding Violations, 0 P-bit Err Secs                               
     0 P-bit Severely Err Secs, 0 Severely Err Framing Secs                    
     20 Unavailable Secs, 20 Line Errored Secs                                 
     0 C-bit Errored Secs, 0 C-bit Severely Errored Secs                       
     20 Severely Errored Line Secs, 1 Path Failures                            
     0 AIS Defect Secs, 20 LOS Defect Secs                                     
   Far End                                                                     
     0 Errored Secs, 0 Severely Errored Secs                                   
     0 C-bit Unavailable Secs, 0 Path Failures                                 
     0 Code Violations, 0 Service Affecting Secs                               
  Total Data (last 1 15 minute intervals):                                     
   Near End                                                                    
     0 Line Code Violations, 0 P-bit Coding Violations,                        
     0 C-bit Coding Violations, 0 P-bit Err Secs,                              
     0 P-bit Severely Err Secs, 0 Severely Err Framing Secs,                   
     20 Unavailable Secs, 20 Line Errored Secs,                                
     0 C-bit Errored Secs, 0 C-bit Severely Errored Secs                       
     20 Severely Errored Line Secs, 1 path failures                            
     0 AIS Defect Secs, 20 LOS Defect Secs                                     
   Far End                                                                     
     0 Errored Secs, 0 Severely Errored Secs                                   
     0 C-bit Unavailable Secs, 0 Path Failures                                 
     0 Code Violations, 0 Service Affecting Secs 

T1 1 is up
  timeslots: 
  FDL per AT&T 54016 spec.
  No alarms detected.     
  Framing is ESF, Clock Source is Internal
  Data in current interval (250 seconds elapsed):
   Near End                                      
     0 Line Code Violations, 0 Path Code Violations
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs       
     0 Unavailable Secs, 0 Stuffed Secs                           
     0 Path Failures, 0 SEF/AIS Secs                              
   Far End                                                        
     0 Line Code Violations, 0 Path Code Violations               
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs       
     0 Unavailable Secs 0 Path Failures                           
  Data in Interval 1:                                             
   Near End                                                       
     0 Line Code Violations, 0 Path Code Violations               
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     2 Errored Secs, 0 Bursty Err Secs, 2 Severely Err Secs       
     0 Unavailable Secs, 0 Stuffed Secs                           
     1 Path Failures, 2 SEF/AIS Secs                              
   Far End                                                        
     0 Line Code Violations, 0 Path Code Violations               
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     3 Errored Secs, 0 Bursty Err Secs, 3 Severely Err Secs       
     0 Unavailable Secs 0 Path Failures                           
  Total Data (last 1 15 minute intervals):                        
   Near End                                                       
     0 Line Code Violations,0 Path Code Violations,               
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,
     2 Errored Secs, 0 Bursty Err Secs, 2 Severely Err Secs        
     0 Unavailable Secs, 0 Stuffed Secs                            
     1 Path Failures, 2 SEF/AIS Secs                               
   Far End                                                         
     0 Line Code Violations,0 Path Code Violations                 
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,
     3 Errored Secs, 0 Bursty Err Secs, 3 Severely Err Secs        
     0 Unavailable Secs, 0 Path Failures 

Performance Monitoring

You can view the statistics or error count generated on the TDM lines for T3 interfaces.

enable
configure terminal
controller MediaType 0/0/0
mode t3 
controller t3 0/0/0
framing c-bit
cablelength
long 224-450 ft
short 0-224 ft
controller MediaType 0/0/15
mode t3
controller T3 0/0/15
framing c-bit
cablelength short 

To view the statistics or error count generated on the TDM lines for T3 interfaces, use the show controller command:

Router# show controller T3 0/0/0  
T3 0/0/0 is up.
  Hardware is ASR900-48T3E3-CE

  Applique type is Channelized T3
  No alarms detected.
  MDL transmission is disabled
    
  FEAC code received: No code is being received
  Framing is C-BIT Parity, Line Code is B3ZS, Cablelength Short less than 225ft
  BER thresholds:  SF = 10e-10  SD = 10e-10
  Clock Source is internal
  Equipment customer loopback
  Data in current interval (240 seconds elapsed):                              
   Near End                                                                    
     0 Line Code Violations, 0 P-bit Coding Violations                         
     0 C-bit Coding Violations, 0 P-bit Err Secs                               
     0 P-bit Severely Err Secs, 0 Severely Err Framing Secs                    
     0 Unavailable Secs, 0 Line Errored Secs                                   
     0 C-bit Errored Secs, 0 C-bit Severely Errored Secs                       
     0 Severely Errored Line Secs, 0 Path Failures                             
     0 AIS Defect Secs, 0 LOS Defect Secs                                      
   Far End                                                                     
     0 Errored Secs, 0 Severely Errored Secs                                   
     0 C-bit Unavailable Secs, 0 Path Failures                                 
     0 Code Violations, 0 Service Affecting Secs                               
  Data in Interval 1:                                                          
   Near End                                                                    
     0 Line Code Violations, 0 P-bit Coding Violations                         
     0 C-bit Coding Violations, 0 P-bit Err Secs                               
     0 P-bit Severely Err Secs, 0 Severely Err Framing Secs                    
     20 Unavailable Secs, 20 Line Errored Secs                                 
     0 C-bit Errored Secs, 0 C-bit Severely Errored Secs                       
     20 Severely Errored Line Secs, 1 Path Failures                            
     0 AIS Defect Secs, 20 LOS Defect Secs                                     
   Far End                                                                     
     0 Errored Secs, 0 Severely Errored Secs                                   
     0 C-bit Unavailable Secs, 0 Path Failures                                 
     0 Code Violations, 0 Service Affecting Secs                               
  Total Data (last 1 15 minute intervals):                                     
   Near End                                                                    
     0 Line Code Violations, 0 P-bit Coding Violations,                        
     0 C-bit Coding Violations, 0 P-bit Err Secs,                              
     0 P-bit Severely Err Secs, 0 Severely Err Framing Secs,                   
     20 Unavailable Secs, 20 Line Errored Secs,                                
     0 C-bit Errored Secs, 0 C-bit Severely Errored Secs                       
     20 Severely Errored Line Secs, 1 path failures                            
     0 AIS Defect Secs, 20 LOS Defect Secs                                     
   Far End                                                                     
     0 Errored Secs, 0 Severely Errored Secs                                   
     0 C-bit Unavailable Secs, 0 Path Failures                                 
     0 Code Violations, 0 Service Affecting Secs                               

  T1 1 is up
  timeslots: 
  FDL per AT&T 54016 spec.
  No alarms detected.     
  Framing is ESF, Clock Source is Internal
  Data in current interval (250 seconds elapsed):
   Near End                                      
     0 Line Code Violations, 0 Path Code Violations
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs       
     0 Unavailable Secs, 0 Stuffed Secs                           
     0 Path Failures, 0 SEF/AIS Secs                              
   Far End                                                        
     0 Line Code Violations, 0 Path Code Violations               
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs       
     0 Unavailable Secs 0 Path Failures                           
  Data in Interval 1:                                             
   Near End                                                       
     0 Line Code Violations, 0 Path Code Violations               
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     2 Errored Secs, 0 Bursty Err Secs, 2 Severely Err Secs       
     0 Unavailable Secs, 0 Stuffed Secs                           
     1 Path Failures, 2 SEF/AIS Secs                              
   Far End                                                        
     0 Line Code Violations, 0 Path Code Violations               
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     3 Errored Secs, 0 Bursty Err Secs, 3 Severely Err Secs       
     0 Unavailable Secs 0 Path Failures                           
  Total Data (last 1 15 minute intervals):                        
   Near End                                                       
     0 Line Code Violations,0 Path Code Violations,               
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,
     2 Errored Secs, 0 Bursty Err Secs, 2 Severely Err Secs        
     0 Unavailable Secs, 0 Stuffed Secs                            
     1 Path Failures, 2 SEF/AIS Secs                               
   Far End                                                         
     0 Line Code Violations,0 Path Code Violations                 
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,
     3 Errored Secs, 0 Bursty Err Secs, 3 Severely Err Secs        
     0 Unavailable Secs, 0 Path Failures 

Use Case 1

If your configuration is as follows:

  • T3 is up

  • No Alarms

  • Framing is unframed

  • Clock Source is Internal

This performance monitoring result is displayed:
T3 is up
No alarms detected.
Framing is unframed, Clock Source is Internal
Data in current interval (240 seconds elapsed):                              
   Near End                                                                    
     0 Line Code Violations, 0 P-bit Coding Violations                         
     0 C-bit Coding Violations, 0 P-bit Err Secs                               
     0 P-bit Severely Err Secs, 0 Severely Err Framing Secs                    
     0 Unavailable Secs, 0 Line Errored Secs                                   
     0 C-bit Errored Secs, 0 C-bit Severely Errored Secs                       
     0 Severely Errored Line Secs, 0 Path Failures                             
     0 AIS Defect Secs, 0 LOS Defect Secs                                      
   Far End                                                                     
     0 Errored Secs, 0 Severely Errored Secs                                   
     0 C-bit Unavailable Secs, 0 Path Failures                                 
     0 Code Violations, 0 Service Affecting Secs                               
  Data in Interval 1:                                                          
   Near End                                                                    
     0 Line Code Violations, 0 P-bit Coding Violations                         
     0 C-bit Coding Violations, 0 P-bit Err Secs                               
     0 P-bit Severely Err Secs, 0 Severely Err Framing Secs                    
     20 Unavailable Secs, 20 Line Errored Secs                                 
     0 C-bit Errored Secs, 0 C-bit Severely Errored Secs                       
     20 Severely Errored Line Secs, 1 Path Failures                            
     0 AIS Defect Secs, 20 LOS Defect Secs                                     
   Far End                                                                     
     0 Errored Secs, 0 Severely Errored Secs                                   
     0 C-bit Unavailable Secs, 0 Path Failures                                 
     0 Code Violations, 0 Service Affecting Secs                               
  Total Data (last 1 15 minute intervals):                                     
   Near End                                                                    
     0 Line Code Violations, 0 P-bit Coding Violations,                        
     0 C-bit Coding Violations, 0 P-bit Err Secs,                              
     0 P-bit Severely Err Secs, 0 Severely Err Framing Secs,                   
     20 Unavailable Secs, 20 Line Errored Secs,                                
     0 C-bit Errored Secs, 0 C-bit Severely Errored Secs                       
     20 Severely Errored Line Secs, 1 path failures                            
     0 AIS Defect Secs, 20 LOS Defect Secs                                     
   Far End                                                                     
     0 Errored Secs, 0 Severely Errored Secs                                   
     0 C-bit Unavailable Secs, 0 Path Failures                                 
     0 Code Violations, 0 Service Affecting Secs                               

  T1 1 is up
  timeslots: 
  FDL per AT&T 54016 spec.
  No alarms detected.     
  Framing is ESF, Clock Source is Internal
  Data in current interval (250 seconds elapsed):
   Near End                                      
     0 Line Code Violations, 0 Path Code Violations
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs       
     0 Unavailable Secs, 0 Stuffed Secs                           
     0 Path Failures, 0 SEF/AIS Secs                              
   Far End                                                        
     0 Line Code Violations, 0 Path Code Violations               
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs       
     0 Unavailable Secs 0 Path Failures                           
  Data in Interval 1:                                             
   Near End                                                       
     0 Line Code Violations, 0 Path Code Violations               
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     2 Errored Secs, 0 Bursty Err Secs, 2 Severely Err Secs       
     0 Unavailable Secs, 0 Stuffed Secs                           
     1 Path Failures, 2 SEF/AIS Secs                              
   Far End                                                        
     0 Line Code Violations, 0 Path Code Violations               
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     3 Errored Secs, 0 Bursty Err Secs, 3 Severely Err Secs       
     0 Unavailable Secs 0 Path Failures                           
  Total Data (last 1 15 minute intervals):                        
   Near End                                                       
     0 Line Code Violations,0 Path Code Violations,               
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,
     2 Errored Secs, 0 Bursty Err Secs, 2 Severely Err Secs        
     0 Unavailable Secs, 0 Stuffed Secs                            
     1 Path Failures, 2 SEF/AIS Secs                               
   Far End                                                         
     0 Line Code Violations,0 Path Code Violations                 
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,
     3 Errored Secs, 0 Bursty Err Secs, 3 Severely Err Secs        
     0 Unavailable Secs, 0 Path Failures 

Use Case 2

If your configuration is as follows:

  • T1 28 is up or E1 16 is up

  • No alarm received

  • Framing is unframed

  • Clock Source is Internal

This performance monitoring result is displayed:

T1 28 is up
No alarms detected.
Framing is unframed, Clock Source is Internal
Data in current interval (240 seconds elapsed):                              
   Near End                                                                    
     0 Line Code Violations, 0 P-bit Coding Violations                         
     0 C-bit Coding Violations, 0 P-bit Err Secs                               
     0 P-bit Severely Err Secs, 0 Severely Err Framing Secs                    
     0 Unavailable Secs, 0 Line Errored Secs                                   
     0 C-bit Errored Secs, 0 C-bit Severely Errored Secs                       
     0 Severely Errored Line Secs, 0 Path Failures                             
     0 AIS Defect Secs, 0 LOS Defect Secs                                      
   Far End                                                                     
     0 Errored Secs, 0 Severely Errored Secs                                   
     0 C-bit Unavailable Secs, 0 Path Failures                                 
     0 Code Violations, 0 Service Affecting Secs                               
  Data in Interval 1:                                                          
   Near End                                                                    
     0 Line Code Violations, 0 P-bit Coding Violations                         
     0 C-bit Coding Violations, 0 P-bit Err Secs                               
     0 P-bit Severely Err Secs, 0 Severely Err Framing Secs                    
     20 Unavailable Secs, 20 Line Errored Secs                                 
     0 C-bit Errored Secs, 0 C-bit Severely Errored Secs                       
     20 Severely Errored Line Secs, 1 Path Failures                            
     0 AIS Defect Secs, 20 LOS Defect Secs                                     
   Far End                                                                     
     0 Errored Secs, 0 Severely Errored Secs                                   
     0 C-bit Unavailable Secs, 0 Path Failures                                 
     0 Code Violations, 0 Service Affecting Secs                               
  Total Data (last 1 15 minute intervals):                                     
   Near End                                                                    
     0 Line Code Violations, 0 P-bit Coding Violations,                        
     0 C-bit Coding Violations, 0 P-bit Err Secs,                              
     0 P-bit Severely Err Secs, 0 Severely Err Framing Secs,                   
     20 Unavailable Secs, 20 Line Errored Secs,                                
     0 C-bit Errored Secs, 0 C-bit Severely Errored Secs                       
     20 Severely Errored Line Secs, 1 path failures                            
     0 AIS Defect Secs, 20 LOS Defect Secs                                     
   Far End                                                                     
     0 Errored Secs, 0 Severely Errored Secs                                   
     0 C-bit Unavailable Secs, 0 Path Failures                                 
     0 Code Violations, 0 Service Affecting Secs                               

  T1 1 is up
  timeslots: 
  FDL per AT&T 54016 spec.
  No alarms detected.     
  Framing is ESF, Clock Source is Internal
  Data in current interval (250 seconds elapsed):
   Near End                                      
     0 Line Code Violations, 0 Path Code Violations
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs       
     0 Unavailable Secs, 0 Stuffed Secs                           
     0 Path Failures, 0 SEF/AIS Secs                              
   Far End                                                        
     0 Line Code Violations, 0 Path Code Violations               
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs       
     0 Unavailable Secs 0 Path Failures                           
  Data in Interval 1:                                             
   Near End                                                       
     0 Line Code Violations, 0 Path Code Violations               
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     2 Errored Secs, 0 Bursty Err Secs, 2 Severely Err Secs       
     0 Unavailable Secs, 0 Stuffed Secs                           
     1 Path Failures, 2 SEF/AIS Secs                              
   Far End                                                        
     0 Line Code Violations, 0 Path Code Violations               
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     3 Errored Secs, 0 Bursty Err Secs, 3 Severely Err Secs       
     0 Unavailable Secs 0 Path Failures                           
  Total Data (last 1 15 minute intervals):                        
   Near End                                                       
     0 Line Code Violations,0 Path Code Violations,               
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,
     2 Errored Secs, 0 Bursty Err Secs, 2 Severely Err Secs        
     0 Unavailable Secs, 0 Stuffed Secs                            
     1 Path Failures, 2 SEF/AIS Secs                               
   Far End                                                         
     0 Line Code Violations,0 Path Code Violations                 
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,
     3 Errored Secs, 0 Bursty Err Secs, 3 Severely Err Secs        
     0 Unavailable Secs, 0 Path Failures 

To view the statistics or error count generated on the TDM lines for T3 interfaces, use the show controller command is:

Router# show controllers t3 0/0/0
T3 0/0/0 is down.
  Hardware is ASR900-48T3E3-CE

  Applique type is Channelized T3
  Receiver has loss of signal.
  Framing is Unknown, Line Code is B3ZS, Cablelength Short less than 225ft
  Clock Source is internal
  Equipment customer loopback
  Data in current interval (240 seconds elapsed):                              
   Near End                                                                    
     0 Line Code Violations, 0 P-bit Coding Violations                         
     0 C-bit Coding Violations, 0 P-bit Err Secs                               
     0 P-bit Severely Err Secs, 0 Severely Err Framing Secs                    
     0 Unavailable Secs, 0 Line Errored Secs                                   
     0 C-bit Errored Secs, 0 C-bit Severely Errored Secs                       
     0 Severely Errored Line Secs, 0 Path Failures                             
     0 AIS Defect Secs, 0 LOS Defect Secs                                      
   Far End                                                                     
     0 Errored Secs, 0 Severely Errored Secs                                   
     0 C-bit Unavailable Secs, 0 Path Failures                                 
     0 Code Violations, 0 Service Affecting Secs                               
  Data in Interval 1:                                                          
   Near End                                                                    
     0 Line Code Violations, 0 P-bit Coding Violations                         
     0 C-bit Coding Violations, 0 P-bit Err Secs                               
     0 P-bit Severely Err Secs, 0 Severely Err Framing Secs                    
     20 Unavailable Secs, 20 Line Errored Secs                                 
     0 C-bit Errored Secs, 0 C-bit Severely Errored Secs                       
     20 Severely Errored Line Secs, 1 Path Failures                            
     0 AIS Defect Secs, 20 LOS Defect Secs                                     
   Far End                                                                     
     0 Errored Secs, 0 Severely Errored Secs                                   
     0 C-bit Unavailable Secs, 0 Path Failures                                 
     0 Code Violations, 0 Service Affecting Secs                               
  Total Data (last 1 15 minute intervals):                                     
   Near End                                                                    
     0 Line Code Violations, 0 P-bit Coding Violations,                        
     0 C-bit Coding Violations, 0 P-bit Err Secs,                              
     0 P-bit Severely Err Secs, 0 Severely Err Framing Secs,                   
     20 Unavailable Secs, 20 Line Errored Secs,                                
     0 C-bit Errored Secs, 0 C-bit Severely Errored Secs                       
     20 Severely Errored Line Secs, 1 path failures                            
     0 AIS Defect Secs, 20 LOS Defect Secs                                     
   Far End                                                                     
     0 Errored Secs, 0 Severely Errored Secs                                   
     0 C-bit Unavailable Secs, 0 Path Failures                                 
     0 Code Violations, 0 Service Affecting Secs                               

  T1 1 is up
  timeslots: 
  FDL per AT&T 54016 spec.
  No alarms detected.     
  Framing is ESF, Clock Source is Internal
  Data in current interval (250 seconds elapsed):
   Near End                                      
     0 Line Code Violations, 0 Path Code Violations
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs       
     0 Unavailable Secs, 0 Stuffed Secs                           
     0 Path Failures, 0 SEF/AIS Secs                              
   Far End                                                        
     0 Line Code Violations, 0 Path Code Violations               
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs       
     0 Unavailable Secs 0 Path Failures                           
  Data in Interval 1:                                             
   Near End                                                       
     0 Line Code Violations, 0 Path Code Violations               
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     2 Errored Secs, 0 Bursty Err Secs, 2 Severely Err Secs       
     0 Unavailable Secs, 0 Stuffed Secs                           
     1 Path Failures, 2 SEF/AIS Secs                              
   Far End                                                        
     0 Line Code Violations, 0 Path Code Violations               
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     3 Errored Secs, 0 Bursty Err Secs, 3 Severely Err Secs       
     0 Unavailable Secs 0 Path Failures                           
  Total Data (last 1 15 minute intervals):                        
   Near End                                                       
     0 Line Code Violations,0 Path Code Violations,               
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,
     2 Errored Secs, 0 Bursty Err Secs, 2 Severely Err Secs        
     0 Unavailable Secs, 0 Stuffed Secs                            
     1 Path Failures, 2 SEF/AIS Secs                               
   Far End                                                         
     0 Line Code Violations,0 Path Code Violations                 
     0 Slip Secs, 2 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,
     3 Errored Secs, 0 Bursty Err Secs, 3 Severely Err Secs        
     0 Unavailable Secs, 0 Path Failures  

The performance monitoring result displays the statistics TDM lines for DS1.

Table 1. Feature History Table

Feature Name

Release Information

Description

GR-820-CORE Performance Monitoring

Cisco IOS XE Bengaluru 17.5.1

The show controller tabular command enables you to view the performance monitoring details in tabular form as per GR-820-Core standards.

To view the performance monitoring details on T3 controller, use the show controller t3 tabular command:

Router#show controllers t3 0/2/0 tabular
T3 0/2/0 is up.
  Hardware is ASR900-48T3E3-CE
 
  Applique type is Subrate T3
  No alarms detected.
  MDL transmission is disabled
   
  FEAC code received: No code is being received
  Framing is C-BIT Parity, Line Code is B3ZS, Cablelength Short less than 225ft
  BER thresholds:  SF = 10e-3  SD = 10e-6
  Clock Source is internal
  Equipment customer loopback
  Near End Data
  INTERVAL      CV-L  ES-L  SES-L LOSS-L  CVP-P CVCP-P  ESP-P ESCP-P SESP-P SESCP-P  SAS-P AISS-P  FC-P UASP-P UASCP-P
  19:03-19:11      0     0      0      0      0      0      0      0      0       0      0      0     0      0       0
  18:48-19:03      0     0      0      0      0      0      0      0      0       0      0      0     0      0       0  
  Total            0     0      0      0      0      0      0      0      0       0      0      0     0      0       0  
  Far End Data
  INTERVAL      CVCP-PFE  ESCP-PFE  SESCP-PFE  UASCP-PFE  FCCP-PFE  SASCP-PFE
  19:03-19:11          0         0          0          0         0          0
  18:48-19:03          0         0          0          0         0          0  
  Total                0         0          0          0         0          0  

To view the performance monitoring details on channelised T1-T3 controller, use the show controller t3 tabular command:

Router#show controllers t3 0/2/4 tabular
T3 0/2/4 is down.
  Hardware is ASR900-48T3E3-CE
 
  Applique type is Channelized T3/T1
  Receiver has loss of signal.
  MDL transmission is disabled
   
  FEAC code received: No code is being received
  Framing is C-BIT Parity, Line Code is B3ZS, Cablelength Short less than 225ft
  BER thresholds:  SF = 10e-3  SD = 10e-6
  Clock Source is internal
  Equipment customer loopback
  Near End Data
  INTERVAL      CV-L  ES-L  SES-L LOSS-L  CVP-P CVCP-P  ESP-P ESCP-P SESP-P SESCP-P  SAS-P AISS-P  FC-P UASP-P UASCP-P
  19:02-19:09      0   459    459    459      0      0      0      0      0       0      0      0     1    459     459  
  Far End Data
  INTERVAL      CVCP-PFE  ESCP-PFE  SESCP-PFE  UASCP-PFE  FCCP-PFE  SASCP-PFE
  19:02-19:09          0         0          0          0         0          0  
 
  T3 0/2/4.1 T1 is down
  timeslots:
  FDL per AT&T 54016 spec.
  Receiver is getting AIS.
  Framing is ESF, Clock Source is Internal
  Near End Data
  INTERVAL     CV-L   ES-L   CV-P   ES-P  SES-P  CSS-P  SAS-P  UAS-P   FC-P
  19:02-19:09     0      0      0      0      0      0      0      0      1  
  Far End Data
  INTERVAL     ES-LFE  ES-PFE  SES-PFE  SEFS-PFE  CSS-PFE  UAS-PFE  FC-PFE
  19:02-19:09       0       0        0         0        0        0       0  

Starting with Cisco IOS XE 17.11.1, you can view the previous day performance monitoring details using the following show controller commands for the T1 or E1, and T3 or E3 controllers.

  • show controllers { t1 | e1 | t3 | e3}

  • show controllers { t1 | e1 | t3 | e3} tabular

  • show controllers { t1 | e1 | t3 | e3} remote performance

  • show controllers { t1 | e1 | t3 | e3} remote performance tabular


router#show controllers t3 0/9/1
T3 0/9/1 is down.
  Hardware is NCS4200-48T3E3-CE
  Applique type is Channelized T3/T1
  Receiver has loss of signal.
  MDL transmission is disabled
    
  FEAC code received: No code is being received
  Framing is C-BIT Parity, Line Code is B3ZS, Cablelength Short less than 225ft
  BER thresholds:  SF = 10e-3  SD = 10e-6
  Clock Source is internal
  Equipment customer loopback
  Data in current interval (220 seconds elapsed):
...........
     0 Code Violations, 0 Service Affecting Secs
  Total Data (last 24 hours)
   Near End
     0 Line Code Violations, 0 P-bit Coding Violation,
     0 C-bit Coding Violation, 0 P-bit Err Secs,
     0 P-bit Severely Err Secs, 0 Severely Err Framing Secs,
     86423 Unavailable Secs, 86423 Line Errored Secs,
     0 C-bit Errored Secs, 0 C-bit Severely Errored Secs
     86423 Severely Errored Line Secs, 0 path failures
     0 AIS Defect Secs, 86423 LOS Defect Secs
   Far End
     0 Errored Secs, 0 Severely Errored Secs
     0 C-bit Unavailable Secs, 0 Path Failures
     0 Code Violations, 0 Service Affecting Secs
  Total (Previous Day)
   Near End
     0 Line Code Violations, 0 P-bit Coding Violation,
     0 C-bit Coding Violation, 0 P-bit Err Secs,
     0 P-bit Severely Err Secs, 0 Severely Err Framing Secs,
     86440 Unavailable Secs, 86440 Line Errored Secs,
     0 C-bit Errored Secs, 0 C-bit Severely Errored Secs
     86440 Severely Errored Line Secs, 2 path failures
     0 AIS Defect Secs, 86440 LOS Defect Secs
   Far End
     0 Errored Secs, 0 Severely Errored Secs
     0 C-bit Unavailable Secs, 0 Path Failures
     0 Code Violations, 0 Service Affecting Secs

  T3 0/9/1.1 T1 is down
  timeslots: 1-3
  FDL per AT&T 54016 spec.
  Receiver is getting AIS.
  Framing is ESF, Clock Source is Internal
  Data in current interval (220 seconds elapsed):
   Near End
     0 Line Code Violations, 0 Path Code Violations
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs
     219 Unavail Secs, 0 Stuffed Secs
     0 Path Failures, 0 SEF/AIS Secs
   Far End
     0 Line Code Violations, 0 Path Code Violations
...................
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs
     0 Unavail Secs 0 Path Failures
  Total Data (last 24 hours)
   Near End
     0 Line Code Violations,0 Path Code Violations,
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs
     86423 Unavail Secs, 0 Stuffed Secs
     0 Path Failures, 0 SEF/AIS Secs
   Far End
     0 Line Code Violations,0 Path Code Violations
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs
     0 Unavailable Secs, 0 Path Failures
  Total (Previous Day)
   Near End
     0 Line Code Violations,0 Path Code Violations,
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs
     86415 Unavail Secs, 0 Stuffed Secs
     0 Path Failures, 0 SEF/AIS Secs
   Far End
     0 Line Code Violations,0 Path Code Violations
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs
     0 Unavailable Secs, 0 Path Failures

router#show controllers t3 0/9/1 tabular
T3 0/9/1 is down.
  Hardware is NCS4200-48T3E3-CE
  Applique type is Channelized T3/T1
  Receiver has loss of signal.
  MDL transmission is disabled
    
  FEAC code received: No code is being received
  Framing is C-BIT Parity, Line Code is B3ZS, Cablelength Short less than 225ft
  BER thresholds:  SF = 10e-3  SD = 10e-6
  Clock Source is internal
  Equipment customer loopback
  Near End Data
  INTERVAL      CV-L  ES-L  SES-L LOSS-L  CVP-P CVCP-P  ESP-P ESCP-P SESP-P SESCP-P  SAS-P AISS-P  FC-P UASP-P UASCP-P
  06:11-06:15      0   249    249    249      0      0      0      0      0       0      0      0     0    249     249
  05:56-06:11      0   900    900    900      0      0      0      0      0       0      0      0     0    900     900
  05:41-05:56      0   900    900    900      0      0      0      0      0       0      0      0     0    900     900
...........................
  06:26-06:41      0   900    900    900      0      0      0      0      0       0      0      0     0    900     900
  06:11-06:26      0   901    901    901      0      0      0      0      0       0      0      0     0    901     901
  Total            0 86423  86423  86423      0      0      0      0      0       0      0      0     0  86423   86423  
  Total (Previous Day)     
  05:26-05:26      0 86440  86440  86440      0      0      0      0      0       0      0      0     2  86440   86440  
  Far End Data
  INTERVAL      CVCP-PFE  ESCP-PFE  SESCP-PFE  UASCP-PFE  FCCP-PFE  SASCP-PFE
  06:11-06:15          0         0          0          0         0          0  
  05:56-06:11          0         0          0          0         0          0  
...........................
  06:11-06:26          0         0          0          0         0          0  
  Total                0         0          0          0         0          0  
  Total (Previous Day)    
  05:26-05:26          0         0          0          0         0          0  

  T3 0/9/1.1 T1 is down
  timeslots: 1-3
  FDL per AT&T 54016 spec.
  Receiver is getting AIS.
  Framing is ESF, Clock Source is Internal
  Near End Data
  INTERVAL     CV-L   ES-L   CV-P   ES-P  SES-P  CSS-P  SAS-P  UAS-P   FC-P
  06:11-06:15     0      0      0      0      0      0      0    249      0
  05:56-06:11     0      0      0      0      0      0      0    900      0
  05:41-05:56     0      0      0      0      0      0      0    900      0
........................
  06:26-06:41     0      0      0      0      0      0      0    900      0
  06:11-06:26     0      0      0      0      0      0      0    901      0
  Total           0      0      0      0      0      0      0  86423      0  
  Total (Previous Day)
  05:26-05:26     0      0      0      0      0      0      0  86415      0
  Far End Data
  INTERVAL     ES-LFE  ES-PFE  SES-PFE  SEFS-PFE  CSS-PFE  UAS-PFE  FC-PFE
  06:11-06:15       0       0        0         0        0        0       0  
..........................
  06:56-07:11       0       0        0         0        0        0       0  
  06:41-06:56       0       0        0         0        0        0       0  
  06:26-06:41       0       0        0         0        0        0       0  
  06:11-06:26       0       0        0         0        0        0       0  
  Total             0       0        0         0        0        0       0  
  Total (Previous Day)    
  05:26-05:26       0       0        0         0        0        0       0

  T3 0/9/1.2 T1 is down
  timeslots: 
  FDL per AT&T 54016 spec.
  Receiver is getting AIS.
  Framing is ESF, Clock Source is Internal
  Near End Data
  INTERVAL     CV-L   ES-L   CV-P   ES-P  SES-P  CSS-P  SAS-P  UAS-P   FC-P
  06:11-06:15     0      0      0      0      0      0      0    249      0
  05:56-06:11     0      0      0      0      0      0      0    900      0  

router#show controllers t3 0/9/1 remote performance

T3 0/9/1 is down.
  Hardware is NCS4200-48T3E3-CE

  Applique type is Channelized T3/T1
  Receiver has loss of signal.
  MDL transmission is disabled
    
  FEAC code received: No code is being received
  Framing is C-BIT Parity, Line Code is B3ZS, Cablelength Short less than 225ft
  BER thresholds:  SF = 10e-3  SD = 10e-6
  Clock Source is internal
  Equipment customer loopback
  Data in current interval (250 seconds elapsed):
   Near End
     0 Line Code Violations, 0 P-bit Coding Violation
     0 C-bit Coding Violation, 0 P-bit Err Secs
..................
     901 Severely Errored Line Secs, 0 Path Failures
     0 AIS Defect Secs, 901 LOS Defect Secs
   Far End
     0 Errored Secs, 0 Severely Errored Secs
     0 C-bit Unavailable Secs, 0 Path Failures
     0 Code Violations, 0 Service Affecting Secs
  Total Data (last 24 hours)
   Near End
     0 Line Code Violations, 0 P-bit Coding Violation,
     0 C-bit Coding Violation, 0 P-bit Err Secs,
     0 P-bit Severely Err Secs, 0 Severely Err Framing Secs,
     86423 Unavailable Secs, 86423 Line Errored Secs,
     0 C-bit Errored Secs, 0 C-bit Severely Errored Secs
     86423 Severely Errored Line Secs, 0 path failures
     0 AIS Defect Secs, 86423 LOS Defect Secs
   Far End
     0 Errored Secs, 0 Severely Errored Secs
     0 C-bit Unavailable Secs, 0 Path Failures
     0 Code Violations, 0 Service Affecting Secs
  Total (Previous Day)
   Near End
     0 Line Code Violations, 0 P-bit Coding Violation,
     0 C-bit Coding Violation, 0 P-bit Err Secs,
     0 P-bit Severely Err Secs, 0 Severely Err Framing Secs,
     86440 Unavailable Secs, 86440 Line Errored Secs,
     0 C-bit Errored Secs, 0 C-bit Severely Errored Secs
     86440 Severely Errored Line Secs, 2 path failures
     0 AIS Defect Secs, 86440 LOS Defect Secs
   Far End
     0 Errored Secs, 0 Severely Errored Secs
     0 C-bit Unavailable Secs, 0 Path Failures
     0 Code Violations, 0 Service Affecting Secs

  T1 1 - Remote Performance Data
  Data in current interval (260 seconds elapsed):
     0 Line Code Violations, 0 Path Code Violations
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs
     0 Unavail Secs
  Data in Interval 1:
     0 Line Code Violations, 0 Path Code Violations
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs
     0 Unavail Secs
  Data in Interval 2:
     0 Line Code Violations, 0 Path Code Violations
.......................
  Data in Interval 96:
     0 Line Code Violations, 0 Path Code Violations
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs
     0 Unavail Secs
  Total Data (last 24 hours)
     0 Path Code Violations
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs
     0 Unavail Secs
  Total (Previous Day) 
     0 Path Code Violations
     0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,
     0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs
     0 Unavail Secs

  T1 2 - Remote Performance Data
  Data in current interval (260 seconds elapsed):
     0 Line Code Violations, 0 Path Code Violations

router#show controllers t3 0/9/1 remote performance tabular

T3 0/9/1 is down.
  Hardware is NCS4200-48T3E3-CE

  Applique type is Channelized T3/T1
  Receiver has loss of signal.
  MDL transmission is disabled
    
  FEAC code received: No code is being received
  Framing is C-BIT Parity, Line Code is B3ZS, Cablelength Short less than 225ft
  BER thresholds:  SF = 10e-3  SD = 10e-6
  Clock Source is internal
  Equipment customer loopback
  Near End Data
  INTERVAL      CV-L  ES-L  SES-L LOSS-L  CVP-P CVCP-P  ESP-P ESCP-P SESP-P SESCP-P  SAS-P AISS-P  FC-P UASP-P UASCP-P
  06:11-06:16      0   279    279    279      0      0      0      0      0       0      0      0     0    279     279
  05:56-06:11      0   900    900    900      0      0      0      0      0       0      0      0     0    900     900
  05:41-05:56      0   900    900    900      0      0      0      0      0       0      0      0     0    900     900
................
  06:11-06:26      0   901    901    901      0      0      0      0      0       0      0      0     0    901     901  
  Total            0 86423  86423  86423      0      0      0      0      0       0      0      0     0  86423   86423  
  Total (Previous Day)
  05:26-05:26      0 86440  86440  86440      0      0      0      0      0       0      0      0     2  86440   86440  
  Far End Data
  INTERVAL      CVCP-PFE  ESCP-PFE  SESCP-PFE  UASCP-PFE  FCCP-PFE  SASCP-PFE
  06:11-06:16          0         0          0          0         0          0  
  05:56-06:11          0         0          0          0         0          0  
  05:41-05:56          0         0          0          0         0          0  
...............
  06:11-06:26          0         0          0          0         0          0  
  Total                0         0          0          0         0          0  
  Total (Previous Day)   
  05:26-05:26          0         0          0          0         0          0  

  T1 1 - Remote Performance Data
  INTERVAL      LCV   PCV   CSS  SELS   LES    DM    ES   BES   SES   UAS
  06:11-06:16     0     0     0     0     0     0     0     0     0     0
  05:56-06:11     0     0     0     0     0     0     0     0     0     0
  05:41-05:56     0     0     0     0     0     0     0     0     0     0
..............
  06:56-07:11     0     0     0     0     0     0     0     0     0     0
  06:41-06:56     0     0     0     0     0     0     0     0     0     0
  06:26-06:41     0     0     0     0     0     0     0     0     0     0
  06:11-06:26     0     0     0     0     0     0     0     0     0     0  
  Total           0     0     0     0     0     0     0     0     0     0  
  Total (Previous Day)     
  05:26-05:26      0     0     0     0     0     0     0     0     0     0  

  T1 2 - Remote Performance Data
  INTERVAL      LCV   PCV   CSS  SELS   LES    DM    ES   BES   SES   UAS
  06:11-06:16     0     0     0     0     0     0     0     0     0     0
  05:56-06:11     0     0     0     0     0     0     0     0     0     0
  05:41-05:56     0     0     0     0     0     0     0     0     0     0  

Clearing the PMON Data

The PMON data for the device is collected and stored every 15 minutes. A total of 96 PMON datasets are collected for a day (24 hours). You can view the PMON data by using the show controller command. However, if required, the dataset can be reset using the clear counters command.

Table 2. Feature History

Feature Name

Release Information

Description

Clear Counters command

Cisco IOS XE 17.15.1
  • Unlike the previous release, where the clear counters command reset the old dataset, from this release onwards, the command resets all the PMON datasets, including the current dataset.

  • You can clear the PMON data for a specific interface module on the device using the clear controller hw-module command


Note


The clear counters command erases all the PMON data that can’t be retrieved. Use the command carefully and only if necessary.


Following are the different clear counters command:

  • Use the following command if you want to clear the PMON data for all interface modules on the device:
    clear counters
  • Use the following command if you want to clear the PMON data for a specific interface module:
    clear controller hw-module <Slot>

The command is useful in the following scenarios:

The command is useful when there is a need for a fresh set of data, like troubleshooting any network issues or monitoring the performance of a new configuration. After clearing, you can then monitor and analyze the new data that gets collected.