Installing the Cisco Nexus 1000V Software

This chapter contains the following sections:

Installation Workflow

Steps to Install Cisco Nexus 1000V Manually

You can install Cisco Nexus 1000V manually. Use these high-level steps and the workflow diagram in the section to guide you through the installation process.

Procedure
    Step 1   Make sure that all of the VMware prerequisites have been met.

    For details, see the following sections:

    Step 2   Make sure that all of the Cisco Nexus 1000V prerequisites have been met.

    For details, see the following sections:.

    Step 3   Read and follow the guidelines and limitations for the Cisco Nexus 1000V.

    For details, see Guidelines and Limitations for Installing the Cisco Nexus 1000V.

    Step 4   Make topology decisions and gather any necessary information.

    For details, see Information Required for Installation.

    Step 5   Download the Cisco Nexus 1000V software.
    Step 6   (Optional)Verify the authenticity of the Cisco Nexus 1000V image.

    For details, see Verifying the Authenticity of the Cisco-Signed Image (Optional)

    Step 7   Install the Virtual Supervisor Module (VSM) software from an ISO image, OVA image, or on a Cisco Nexus Cloud Services Platform.

    For details, see one of the following sections:

    Step 8   If you installed the VSM software on a CSP, proceed to the next step. If you installed the VSM software on a VM using an ISO or OVA image, you need to establish the SVS connection and configure the VM startup and shutdown parameters.

    For details, see Establishing the SVS Connection and Setting Virtual Machine Startup and Shutdown Parameters.

    Step 9   Add the VEM hosts to the Distributed Virtual Switch.

    For details, see Adding VEM Hosts to the Cisco Nexus 1000V Distributed Virtual Switch.

    Step 10   If you want to install the VEM software on a stateless ESXi host, proceed to the next step. Otherwise, install the VEM software using VUM, the Cisco Nexus 1000VCLI, or the VMware ESXi CLI.

    For details, see one of the following sections:

    Step 11   Install the VEM software on a stateless ESXi host.

    For more details, see Installing the VEM Software on a Stateless ESXi Host.


    Process Flowchart for Installing the Cisco Nexus 1000V Manually

    Use the procedures in this chapter and the following workflow as a guide to install the Cisco Nexus 1000V for VMware manually.



    Supported VMware vSphere ESXi Hypervisor Versions

    Cisco Nexus 1000V supports the following VMware vSphere ESXi Hypervisor versions:

    • 6.0

    • 5.5

    • 5.1

    • 5.0

    For information about installing or upgrading the VMware software, see Installing and Upgrading VMware.

    See the following table for detailed compatibility information.


    Note


    Do not install VMware vSphere 5.5 Patch 2702864 with Cisco Nexus 1000V. The VMware vSphere 5.5 Patch 2702864 is not supported on Cisco Nexus 1000V.


    Table 1 VMware vSphere ESXi Hypervisor Software Compatibility Versions

    VMware

    1

    VIB

    2

    VEM Bundle

    3

    Windows VC Installer

    Linux vCenter Server Appliance

    VMware vSphere CLI

    Power-Shell CLI

    ESXi 6.0

    cross_cisco-vem- v199-5.2.1.3.1.5b.0-6.0.1.vib

    VEM600-201509199119-BG- release.zip (Offline)

    VEM600-201509199119-BG (Online)

    6.0

    6.0

    6.0

    6.0

    ESXi 5.5

    4

    cross_cisco-vem- v199-5.2.1.3.1.5b.0-3.2.1.vib

    VEM550-201509199113-BG- release.zip (Offline)

    VEM550-201509199113-BG (Online)

    5.5

    5.5

    5.5

    5.5

    ESXi 5.1

    cross_cisco-vem- v199-5.2.1.3.1.5b.0-3.1.1.vib

    VEM510-201509199107-BG- release.zip (Offline)

    VEM510-201509199107-BG (Online)

    5.1

    5.1

    5.1

    5.1

    ESXi 5.0

    cross_cisco-vem- v199-5.2.1.3.1.5b.0-3.0.1.vib

    VEM500-201509199101-BG- release.zip (Offline)

    VEM500-201509199101-BG (Online)

    5.0

    5.0

    5.0

    5.0

    1 Includes patches and updates.
    2 VIB files are available at http://www.vmware.com/patch/download.
    3 VMware bundled software updates require placing the host in maintenance mode.
    4 Do not install the VMware vSphere 5.5 Patch 2702864. The VMware vSphere 5.5 Patch 2702864 is not supported on Cisco Nexus 1000V.

    Prerequisites for Installing the Cisco Nexus 1000V

    ESXi Host Prerequisites

    ESX or ESXi hosts have the following prerequisites:

    • You have already installed and prepared vCenter Server for host management using the instructions from VMware.

    • You should have VMware vSphere Client installed.

    • You have already installed the VMware Enterprise Plus license on the hosts.

    • All VEM hosts must be running ESXi 5.0 or later releases.

    • You have two physical NICs on each host for redundancy. Deployment is also possible with one physical NIC.

    • If you are using a set of switches, make sure that the interswitch trunk links carry all relevant VLANs, including control and packet VLANs. The uplink should be a trunk port that carries all VLANs that are configured on the host.

    • You must configure control and management VLANs on the host to be used for the VSM VM.

    • Make sure that the VM to be used for the VSM meets the minimum requirements listed in the following table.

    • All the vmnics should have the same configuration upstream.


    Caution


    • VSM hardware version 11 is not supported. See table below for supported versions.

    • The VSM VM might fail to boot if RAM and CPU are not properly allocated. This document includes procedures for allocating RAM and setting the CPU speed.

    The VSM VM might fail to boot if RAM and CPU are not properly allocated. This document includes procedures for allocating RAM and setting the CPU speed.

    This table lists the minimum requirements for hosting a VSM.

    Table 2 Minimum Requirements for a VM Hosting a VSM

    VSM VM Component

    Minimum Requirement

    VSM Hardware Version

    7

    Note   

    VSM hardware versions 7, 8, 9, and 10 are supported. VSM hardware version 11 is not supported.

    Platform

    64 bit

    Type

    Other 64-bit Linux (recommended)

    Processor

    2

    RAM (configured and reserved)

    4 GB5

    NIC

    3

    SCSI Hard Disk

    3 GB with LSI Logic Parallel adapter

    CPU speed

    2048 MHz6

    5 If you are installing the VSM using an OVA file, the correct RAM setting is made automatically during the installation of this file. If you are using the CD ISO image, see Installing the Software from the ISO Image to reserve RAM and set the memory size.
    6 If you are installing the VSM using an OVA file, the correct CPU speed setting is made automatically during the installation. If you are using the CD ISO image, see Installing the Software from the ISO Image to reserve CPU and set the CPU reservation.

    VSM Prerequisites

    The Cisco Nexus 1000V VSM software has the following are prerequisites:

    • You have the VSM IP address.

    • You have installed the appropriate vCenter Server and VMware Update Manager (VUM) versions.

    • If you are installing redundant VSMs, make sure that you first install and set up the software on the primary VSM before installing and setting up the software on the secondary VSM.

    • If you are using the OVA file for installation, make sure that the CPU speed is 2048 MHz or greater. If the CPU speed is less than 2048 MHz, then use ISO image for installation.

    • You have already identified the HA role for this VSM from the list in the following table.

    Table 3 HA Roles

    HA Role

    Single Supervisor System

    Dual Supervisor System

    Standalone (test environment only)

    X

     

    HA

     

    X


    Note


    A standalone VSM is not supported in a production environment.


    VEM Prerequisites

    The Cisco Nexus 1000V VEM software has the following prerequisites:


    Note


    If VMware vCenter Server is hosted on the same ESXi host as a Cisco Nexus 1000V VEM, a VUM-assisted upgrade on the host will fail. You should manually VMotion the vCenter Server VM to another host before you perform an upgrade.


    • When you perform any VUM operation on hosts that are a part of a cluster, ensure that VMware fault tolerance (FT) and VMware distributed power management (DPM) features are disabled for the entire cluster. Otherwise, VUM cannot install the hosts in the cluster.

    • If the hosts are in ESXi stateless mode, enable the PXE booted ESXi host settings under Home > Update Manager > Configuration > ESXi host/cluster.

    • You have a copy of your VMware documentation available for installing software on a host.

    • You have already obtained a copy of the VEM software file from one of the sources listed in VEM Software.

    • You have already downloaded the correct VEM software based on the current ESXi host patch level. For more information, see the Cisco Nexus 1000V and VMware Compatibility Information.

    • For a VUM-based installation, you must deploy VUM and make sure that the VSM is connected to vCenter Server.

    Upstream Switch Prerequisites

    The upstream switch from the Cisco Nexus 1000V has the following prerequisites:

    • If you are using a set of switches, make sure that the interswitch trunk links carry all relevant VLANs, including the control and packet VLANs. The uplink must be a trunk port that carries all the VLANs that are configured on the host.

    • The following spanning tree prerequisites apply to the upstream switch from the Cisco Nexus 1000V on the ports that are connected to the VEM.
      • On upstream switches, the following configuration is mandatory:

        On your Catalyst series switches with Cisco IOS software, enter the spanning-tree portfast trunk or spanning-tree portfast edge trunk command.

        On your Cisco Nexus 5000 series switches with Cisco NX-OS software, enter the spanning-tree port type edge trunk command.

      • On upstream switches we highly recommend that you enable Global BPDU Filtering and Global BPDU Guard globally.

      • On upstream switches, where you cannot globally enable BPDU Filtering and BPDU Guard, we highly recommend that you enter the spanning-tree bpdu filter and spanning-tree bpdu guardcommands.

      For more information about spanning tree and its supporting commands, see the documentation for your upstream switch.

    • Enter the following commands on the upstream switch:

      show running interface interface number  
      interface GigabitEthernet interface number
       description description of interface 
      switchport
      switchport trunk encapsulation dot1q
      switchport trunk native VLAN native VLAN 
      switchport trunk allowed vlan list of VLANs 
      switchport mode trunk 
      
      end
      

    Guidelines and Limitations for Installing the Cisco Nexus 1000V

    The Cisco Nexus 1000V software installation has the following configuration guidelines and limitations:

    • Virtual machine hardware version 11 is not supported.

    • Do not enable VMware fault tolerance (FT) for the VSM VM because it is not supported. Instead, Cisco NX-OS HA provides high availability for the VSM.

    • The VSM VM supports VMware HA. However, we strongly recommend that you deploy redundant VSMs and configure Cisco NX-OS HA between them. Use the VMware recommendations for the VMware HA.

    • Do not enable VM monitoring for the VSM VM because it is not supported, even if you enable the VMware HA on the underlying host. Cisco NX-OS redundancy is the preferred method.

    • When you move a VSM from the VMware vSwitch to the Cisco Nexus 1000V DVS, the connectivity between the active and standby VSM might get temporarily lost. In that situation, both active and standby VSMs assume the active role.

      The reboot of the VSM is based on the following conditions:
      1. The number of modules attached to the VSM

        • If more modules are attached on one of the VSMs and there is no virtual channel (VC) connectivity on both VSMs, the VSM that has the smaller number of modules is rebooted.

        • If modules are attached to both VSMs and one of the VSMs has VC connectivity, the VSM without connectivity is rebooted.

      2. VC connectivity


        Note


        This option is invoked when the previous condition is not met.


        • If both VSMs have the same number of modules, the software makes a selection that is based on the VC connectivity status.

          For example, this action is taken if both VSMs have two modules attached or both VSMs have no modules attached.

      3. Last configuration change


        Note


        This condition is invoked when the previous two conditions are not met.


        • If both VSMs have the same number of modules and no VC connectivity, the VSM with the latest configuration remains active and the other VSM is rebooted.

      4. Last active VSM

        • If the previous three conditions are not met, the VSM that became active most recently is rebooted.

    • If the VSM is moved from the VMware vSwitch to the Cisco Nexus 1000V DVS, we recommend that you configure port security on the VSM vEthernet interfaces to secure control/packet MAC addresses.

    • To improve redundancy, install primary and secondary VSM VMs on separate hosts that are connected to different upstream switches.

    • The Cisco Nexus 1000V VSM always uses the following three network interfaces in the same order as specified below:

      1. Control Interface
      2. Management Interface
      3. Packet Interface
    • There is no dependency on the VM hardware version, so the VM hardware version can be upgraded if required.

    • We recommend that you deploy the VMware vCenter server and VSM in the same physical data center. If you choose to deploy the vCenter server and VSM in different physical data centers, be aware of the following guidelines and limitations:

      • The VSM HA pair must be located in the same site as their storage and the active vCenter Server.

      • Layer 3 control mode is preferred.

      • If you are using Link Aggregation Control Protocol (LACP) on the VEM, use LACP offload.

      • Quality of Service bandwidth guarantees for control traffic over the DCI link.

      • Limit the number of physical data centers to two.

      • A maximum latency of 10 ms is supported for VSM-VSM control traffic when deployed across datacenters.

      • A maximum latency of 100 ms is supported for VSM-VEM control traffic for both L2 and L3 mode of deployments.

      • Cisco Nexus 1000V Release 5.2(1)SV3(1.1) and later supports deployments where vCenter and VSM are in different data centers, provided the number of hosts does not exceed 35 and the link latency does not exceed 200 ms. In these types of deployments, we recommend that you do not edit port profiles when the VSM and the vCenter are disconnected.

    • We recommend that you monitor and install all the relevant patch applications from VMware ESX host server.

    Information Required for Installation

    Before installing the software, make topology decisions and gather any necessary information, as follows:

    • Decide whether to deploy the VSM as a VM on a vSphere host or cluster or on a CSP.

    • Decide whether to deploy in Layer 2 or Layer 3 control mode (Layer 3 control mode is recommended).

    • For Layer 2 control mode, determine the control or packet VLANs that will be used.

    • For Layer 3 control mode, decide whether the management and Layer 3 control ports will be unified or separate. If they will be separate, determine the IP address of the Layer 3 control port for each ESXi host.

    • Determine the domain ID.

    • Determine the management, subnet, and gateway IP addresses for the VSM.

    • Determine the administrative password for the VSM.

    Verifying the Authenticity of the Cisco-Signed Image (Optional)

    Before you install the Nexus1000v.5.2.1.SV3.1.5b.zip image, you have the option to validate the authenticity of it. In the zip file, there is a signature.txt file that contains a SHA-512 signature and an executable script that can be used to verify the authenticity of the Nexus1000v.5.2.1.SV3.1.5b.zip image.


    Note


    Verifying the authenticity of an image is optional. You can still install the image without validating its authenticity.


    Before You Begin
    You need to be running a Linux machine with the following utilities installed:
    • openssl

    • base64

    Procedure
      Step 1   Copy the following files to a directory on the Linux machine:
      • Nexus1000v.5.2.1.SV3.1.5b.zip

        signature.txt file

      • cisco_n1k_image_validation_v_1_1 script

      Step 2   Ensure that the script is executable.

      chmod 755 cisco_n1k_image_validation_v_1_1

      Step 3   Run the script.

      ./cisco_n1k_image_validation_v_1_1 -s signature.txt Nexus1000v.5.2.1.SV3.1.5b.zip

      Step 4   Check the output. If the validation is successful, the following message displays:
      Authenticity of Cisco-signed image Nexus1000v.5.2.1.SV3.1.5b.zip has been successfully verified!

      Installing the Cisco Nexus 1000V Software Using ISO or OVA Files

      Installing the VSM Software

      Installing the Software from the ISO Image

      Before You Begin
      • Know the location and image name of the ISO image you require for the installation.

      • You have already read the Prerequisites for Installing the Cisco Nexus 1000V.

      • You have already manually provisioned the VM to be used for the VSM. For more information, see the vSphere Virtual Machine Administration Guide.

      • The VSM VM requires the following and this procedure includes steps for updating these properties:

        • We recommend 4 Gigabit of RAM reserved and allocated.

        • We recommend 2048 MHz of CPU speed.

      Procedure
        Step 1   Using your VMware documentation, attach the VSM ISO image to the virtual CD-ROM and copy the software to a virtual machine (VM).
        Step 2   Make sure that the VSM VM is powered off.
        Step 3   In the vSphere client Virtual Machine Properties window Hardware tab, choose Memory.
        Step 4   In the Memory Size field, choose 4 GB.
        Step 5   In the Resources tab, choose Memory.

        The Resource Allocation settings display in the right-hand pane.

        Step 6   In the Reservation field, choose 4096 MB.
        Step 7   In the Resources tab, choose CPU.

        The Resource Allocation settings display in the right-hand pane.

        Step 8   In the Reservation field, choose 2048 MHz.
        Note    For optimum performance, we recommend minimum 2048 MHz of CPU speed. You may change the value as per availability.
        Step 9   Click OK.

        The VSM VM memory and CPU speed settings are saved in VMware vSphere Client.

        Step 10   Right-click the VSM and choose Open Console.
        Step 11   Choose Install Nexus1000V and bring up the new image entry and press Enter.
        Step 12   Enter and confirm the Administrator password.
        Note   

        All alphanumeric characters and symbols on a standard US keyboard are allowed except for these three: $ \ ?

        Step 13   Enter the domain ID. Enter the domain id<1-1023>: 152
        Step 14   Enter the HA role.

        If you do not specify a role, standalone is assigned by default.

        This example shows the HA role as primary.

        Enter HA role[standalone/primary/secondary]: primary
        
        [#########################################] 100%
        
                 ---- Basic System Configuration Dialog ----
        
        This setup utility will guide you through the basic configuration of
        the system. Setup configures only enough connectivity for management
        of the system.
        
        *Note: setup is mainly used for configuring the system initially,
        when no configuration is present. So setup always assumes system
        defaults and not the current system configuration values.
        
        Press Enter at anytime to skip a dialog. Use ctrl-c at anytime
        to skip the remaining dialogs.
        
        Would you like to enter the basic configuration dialog (yes/no): 
        
        
        Step 15   Do one of the following:
        • If you are setting up the primary/active VSM, go to Step 18.

        • If you are setting up the secondary/standby VSM, then continue with the next step.

        Step 16   If you have set up the VSM virtual machine (VM) to boot from the CD-ROM, and are installing the secondary VSM from the ISO image attached to your CD-ROM, remove the virtual CD-ROM now so that the VSM does not boot from the CD.

        This step is necessary if you have set up the VSM VM to boot from the CD-ROM before the hard drive.

        Step 17   If you are setting up the secondary or standby VSM, do the following:
        1. Enter the HA role at the following prompt:
          Enter HA role[standalone/primary/secondary]:
        2. Enter yes at the following prompt about rebooting the VSM:
          Setting HA role to secondary will cause a system reboot. Are you sure (yes/no) ? : 
        3. Enter the domain ID at the following prompt:
          Enter the domain id<1-1023>:

        The secondary VSM VM is rebooted and brought up in standby mode. The password on the secondary VSM is synchronized with the password on the active/primary VSM. Any configuration made on the active/primary VSM is now automatically synchronized with the standby.

        This example shows the system rebooting when the HA role is set to secondary.

        Enter HA role[standalone/primary/secondary]: secondary
        
        Setting HA role to secondary will cause a system reboot. Are you sure (yes/no) ? : y
        
        Enter the domain id<1-1023>: 1020
        [########################################] 100%
        HA mode set to secondary. Rebooting now...

        You have completed this procedure for the secondary VSM.

        Step 18   Enter yes to enter the basic configuration dialog.
        Would you like to enter the basic configuration dialog (yes/no): yes
        Step 19   Enter no to create another Login account.
        Create another login account (yes/no) [n]: no
        Step 20   Enter no to configure a read-only SNMP community string.
        Configure read-only SNMP community string (yes/no) [n]: no
        Step 21   Enter no to configure a read-write SNMP community string.
        Configure read-write SNMP community string (yes/no) [n]: no
        Step 22   Enter a name for the switch.
        Enter the switch name: n1000v
        Step 23   Enter yes to configure out-of-band management and then enter the mgmt0 IPv4 address and subnet mask.
        Continue with Out-of-band (mgmt0) management configuration? [yes/no] [y]: yes
        Mgmt0 IPv4 address: 172.28.15.152
        Mgmt0 IPv4 netmask: 255.255.255.0
        Step 24   Enter yes to configure the default gateway.
        Configure the default-gateway: (yes/no) [y]: yes
        IPv4 address of the default gateway : 172.23.233.1
        Step 25   Enter no to configure advanced IP options.
        Configure Advanced IP options (yes/no)? [n]: no
        Step 26   Enter yes to enable the Telnet service.
        Enable the telnet service? (yes/no) [y]: yes
        Step 27   Enter yes to enable the SSH service and then enter the key type and number of key bits.
        Enable the ssh service? (yes/no) [y]: yes
        Type of ssh key you would like to generate (dsa/rsa) : rsa
        Number of  key bits <768-2048> : 1024

        For more information, see the document, Cisco Nexus 1000V Security Configuration Guide.

        Step 28   Enter yes to enable the HTTP server.
        Enable the http-server? (yes/no) [y]: yes
        Step 29   Enter no to configure the NTP server.
        Configure NTP server? (yes/no) [n]: no
        Step 30   Enter yes to configure the SVS domain parameters and then enter the mode (L2 or L3), and the control and packet VLAN IDs.
        Configure svs domain parameters? (yes/no) [y]: yes
        Enter SVS Control mode (L2 / L3) [L3] : Press Return
        
        Step 31   Enter yes to configure the VEM feature level and then enter 0 or 1.
        Vem feature level will be set to 5.2(1)SV3(1.5b), 
        Do you want to reconfigure? (yes/no) [n] yes
                  Current vem feature level is set to 5.2(1)SV3(1.5b)
                  You can change the feature level to:
                              vem feature level is set to the highest value possible
        Note   

        The feature level is the least VEM release that the VSM can support. For example, if the feature level is set to the 5.2(1)SV3(1.4) release, any VEMs with an earlier release are not attached to the VSM.

        The system now summarizes the complete configuration and asks if you want to edit it.

        The following configuration will be applied:
         Switchname n1000v
        interface Mgmt0
        ip address 172.28.15.152 255.255.255.0
        no shutdown
        no telnet server enable
          ssh key rsa 1024 force
          ssh server enable
          feature http-server
          svs-domain
            no control vlan 
            no packet vlan 
            svs mode L3 interface mgmt0
        Step 32   Do one of the following:
        • If you do not want to edit the configuration enter no and continue with the next step.

        • If you want to edit the configuration, enter yes and return to Step 19 to revisit each command.

        Would you like to edit the configuration? (yes/no) [n]:no
        Step 33   Enter yes to use and save this configuration, answer yes.
        Caution   

        If you do not save the configuration now, none of your changes will be part of the configuration the next time that the switch is rebooted. Enter yes to save the new configuration and to ensure that the kickstart and system images are also automatically configured.

        Use this configuration and save it? (yes/no) [y]: yes
        [########################################] 100%

        The new configuration is saved into nonvolatile storage.

        Note   

        You can use the setup routine to update the configuration done in Step 18 through Step 33 at any time by entering the setup command in EXEC mode. Once setup begins, press Enter to skip a command. Press Ctrl-C to skip the remaining commands.

        If you are installing redundant VSMs, make sure that you configure the software on the primary VSM before installing the software on the secondary VSM.
        Step 34   Create the SVS connection manually or go to Establishing the SVS Connection.

        Installing the Software from an OVA Image

        Before You Begin

        Before beginning this procedure, you must know or do the following:

        • Know the location and image name of the OVA image you require for the installation.

        • You have already read the Prerequisites for Installing the Cisco Nexus 1000V.

        • You have a copy of the following Cisco Nexus 1000V software image files on your local drive, depending on the installation type you are using:

        • For detailed information about using the Deploy OVF Template wizard, see the vSphere Virtual Machine Administration Guide.

        • You have the following information available for creating a VM for the VSM and mapping the required port groups:

          • A name for the new VSM that is unique within the inventory folder and up to 80 characters.

          • The name of the host where the VSM will be installed in the inventory folder.

          • The name of the datastore in which the VM files will be stored.

          • The names of the network port groups used for the VM.

          • The Cisco Nexus 1000V VSM IP address.

        • If you are using the OVA file for installation, make sure that you have the following information available for creating and saving an initial configuration file on the VSM:

          • VSM domain ID

          • Admin password

          • Management IP address, subnet mask, and gateway

        • The VSM VM requires the CPU speed to be 2048 MHz or greater. If the CPU speed is less than 2048 MHz, then do not proceed with this procedure. Instead perform Installing the Software from the ISO Image.

        Procedure
          Step 1   From the vSphere Client, choose File > Deploy OVF Template.
          Step 2   In the Source screen, specify the location of the OVA file and click Next.

          The OVF Template Details screen opens displaying product information, including the size of the file and the size of the VM disk.

          Step 3   Click Next.
          Step 4   Read the Cisco Nexus 1000V License Agreement.
          Step 5   Click Accept and then click Next.
          Step 6   In the Name: field, add the VSM name, choose the folder location within the inventory where it will reside, and click Next.

          The name for the VSM must be unique within the inventory folder and less than 80 characters.

          Step 7   From the Configuration drop-down list, choose Nexus 1000V Installer.

          This choice configures the primary VSM using the GUI setup dialog.

          Step 8   If you want to configure a secondary VSM, select Nexus 1000V Secondary.
          Step 9   Click Next.
          Step 10   Choose the data center or cluster on which to install the VSM.
          Step 11   Click Next.
          Step 12   Choose the datastore in which to store the file if one is available.

          On this page, you choose from datastores already configured on the destination cluster or host. The virtual machine configuration file and virtual disk files are stored on the datastore. Choose a datastore large enough to accommodate the virtual machine and all of its virtual disk files.

          Step 13   Click Next.
          Step 14   Choose one of the following disk formats for storing virtual machine virtual disks, and click Next.

          Format

          Description

          Thick Provision Lazy Zeroed

          Creates a virtual disk in a default thick format. In this format, the space required for the virtual disk is allocated when the disk is created. The data remaining on the physical device is not erased during creation. The data is zeroed out on demand at a later time on first write from the virtual machine. Virtual machines do not read stale data from the physical device.

          Thick Provision Eager Zeroed

          Creates a virtual disk that supports clustering features such as Fault Tolerance. In this format, the space required for the virtual disk is allocated when the disk is created. The data remaining on the physical device is zeroed out when the virtual disk is created. It might take longer to create virtual disks in this format than to create other types of disks.

          Thin Provision

          Creates a virtual disk in thin provision format. This format is useful for saving storage space. In this format, storage blocks are allocated and zeroed out when they are first accessed.

          Thin provisioning is the fastest method to create a virtual disk because it creates a disk with just the header information. It does not allocate or zero out storage blocks. If the thin disk needs more space later, it can grow to its maximum capacity and occupy the entire datastore space provisioned to it.

          Step 15   In the Network Mapping screen, choose the networks (the control, management, and packet port groups) that are present in your inventory.
          Step 16   Click Next
          Step 17   Do one of the following:
          • If you are installing software on a primary VSM, specify the following properties for your primary VSM:

            • VSM domain ID

            • Admin password

            • Management IP address

            • Management IP subnet mask

            • Management IP gateway

          • If you are installing software on a secondary VSM, specify only the following properties for your secondary VSM (all other properties are acquired on synchronization with the primary VSM), and then click Next:

            • VSM domain ID (use the same domain ID entered for the primary).

            • Admin password (use the same password entered for the primary).

          Step 18   Click Next.
          Step 19   In the Ready to Complete screen, if the configuration is correct, click Finish.

          A status bar displays as the VM installation progresses.

          Step 20   Click Close.

          You have completed installing the Cisco Nexus 1000V software.

          Step 21   Right-click the VSM and choose Open Console.
          Step 22   Click the green arrow to power on the VSM.
          Step 23   Enter the following commands at the VSM prompt.
          switch# configure terminal
          switch(config)# setup
          Step 24   Enter the HA role.

          If you do not specify a role, standalone is assigned by default.

          This example shows the HA role as primary.

          Enter HA role[standalone/primary/secondary]: primary
          
          [#########################################] 100%
          
                   ---- Basic System Configuration Dialog ----
          
          This setup utility will guide you through the basic configuration of
          the system. Setup configures only enough connectivity for management
          of the system.
          
          *Note: setup is mainly used for configuring the system initially,
          when no configuration is present. So setup always assumes system
          defaults and not the current system configuration values.
          
          Press Enter at anytime to skip a dialog. Use ctrl-c at anytime
          to skip the remaining dialogs.
          
          Would you like to enter the basic configuration dialog (yes/no): 
          Step 25   Do one of the following:
          • If you are setting up the primary/active VSM, go to Step 18.

          • If you are setting up the secondary/standby VSM, then continue with the next step.

          Step 26   If you have set up the VSM virtual machine (VM) to boot from the CD-ROM, and are installing the secondary VSM from the ISO image attached to your CD-ROM, remove the virtual CD-ROM now so that the VSM does not boot from the CD.

          This step is necessary if you have set up the VSM VM to boot from the CD-ROM before the hard drive.

          Step 27   If you are setting up the secondary or standby VSM, do the following:
          1. Enter the HA role at the following prompt:
            Enter HA role[standalone/primary/secondary]:
          2. Enter yes at the following prompt about rebooting the VSM:
            Setting HA role to secondary will cause a system reboot. Are you sure (yes/no) ? : 
          3. Enter the domain ID at the following prompt:
            Enter the domain id<1-1023>:

          The secondary VSM VM is rebooted and brought up in standby mode. The password on the secondary VSM is synchronized with the password on the active/primary VSM. Any configuration made on the active/primary VSM is now automatically synchronized with the standby.

          This example shows the system rebooting when the HA role is set to secondary.

          Enter HA role[standalone/primary/secondary]: secondary
          
          Setting HA role to secondary will cause a system reboot. Are you sure (yes/no) ? : y
          
          Enter the domain id<1-1023>: 1020
          [########################################] 100%
          HA mode set to secondary. Rebooting now...
          

          You have completed this procedure for the secondary VSM.

          Step 28   Enter yes to enter the basic configuration dialog. Would you like to enter the basic configuration dialog (yes/no): yes
          Step 29   Enter no to create another Login account.
          Create another login account (yes/no) [n]: no
          Step 30   Enter no to configure a read-only SNMP community string.
          Configure read-only SNMP community string (yes/no) [n]: no
          Step 31   Enter no to configure a read-write SNMP community string.
          Configure read-write SNMP community string (yes/no) [n]: no
          Step 32   Enter a name for the switch.
          Enter the switch name: n1000v
          Step 33   Enter yes to configure out-of-band management and then enter the mgmt0 IPv4 address and subnet mask.
          Continue with Out-of-band (mgmt0) management configuration? [yes/no] [y]: yes
          Mgmt0 IPv4 address: 172.28.15.152
          Mgmt0 IPv4 netmask: 255.255.255.0
          Step 34   Enter yes to configure the default gateway.
          Configure the default-gateway: (yes/no) [y]: yes 
          
              IPv4 address of the default gateway : 172.23.233.1
          Step 35   Enter no to configure advanced IP options.
          Configure Advanced IP options (yes/no)? [n]: no
          Step 36   Enter yes to enable the Telnet service.
          Enable the telnet service? (yes/no) [y]: yes
          Step 37   Enter yes to enable the SSH service and then enter the key type and number of key bits.
          Enable the ssh service? (yes/no) [y]: yes
          Type of ssh key you would like to generate (dsa/rsa) : rsa
          Number of  key bits <768-2048> : 1024

          For more information, see the document, Cisco Nexus 1000V Security Configuration Guide.

          Step 38   Enter yes to enable the HTTP server.
          Enable the http-server? (yes/no) [y]: yes
          Step 39   Enter no to configure the NTP server.
          Configure NTP server? (yes/no) [n]: no
          Step 40   Enter yes to configure the SVS domain parameters and then enter the mode (L2 or L3), and the control and packet VLAN IDs.
          Configure svs domain parameters? (yes/no) [y]: yes
          Enter SVS Control mode (L2 / L3) : L2
          Enter control vlan <1-3967, 4048-4093> : 100
          Enter packet vlan <1-3967, 4048-4093> : 101
          Step 41   Enter yes to configure the VEM feature level and then enter 0 or 1.
          Vem feature level will be set to 5.2(1)SV3(1.5b), 
          Do you want to reconfigure? (yes/no) [n] yes
                    Current vem feature level is set to 5.2(1)SV3(1.5b)
                    You can change the feature level to:
                                vem feature level is set to the highest value possible

          The system now summarizes the complete configuration and asks if you want to edit it.

          The following configuration will be applied:
           Switchname n1000v
          interface Mgmt0
          ip address 172.28.15.152 255.255.255.0
          no shutdown
          no telnet server enable
            ssh key rsa 1024 force
            ssh server enable
            feature http-server
            svs-domain
              svs mode L2
              control vlan 100
              packet vlan 101
              domain id 101
          vlan 100
          vlan 101
          Step 42   Do one of the following:
          • If you do not want to edit the configuration enter no and continue with the next step.

          • If you want to edit the configuration, enter yes and return to Step 19 to revisit each command.

          Would you like to edit the configuration? (yes/no) [n]:no
          Step 43   Enter yes to use and save this configuration.
          Caution   

          If you do not save the configuration now, none of your changes will be part of the configuration the next time that the switch is rebooted. Enter yes to save the new configuration and to ensure that the kickstart and system images are also automatically configured.

          Use this configuration and save it? (yes/no) [y]: yes
          [########################################] 100%
          

          The new configuration is saved into nonvolatile storage.

          Note   

          You can use the setup routine to update the configuration done in Step 18 through Step 33 at any time by entering the setup command in EXEC mode. Once setup begins, press Enter to skip a command. Press Ctrl-C to skip the remaining commands.

          Note   

          If you are installing redundant VSMs, make sure that you configure the software on the primary VSM before installing the software on the secondary VSM.

          Step 44   Register the vCenter extension file in VMware vCenter. See Registering a vCenter Extension File in VMware vCenter for more information.
          Step 45   Create the SVS connection manually or go to Establishing the SVS Connection.

          Registering a vCenter Extension File in VMware vCenter

          In VMware vCenter , the vCenter extension files are called plug-ins.

          Before You Begin
          • You know the IP address of the active VSM.

          • You have already downloaded a copy of the following file from the VSM home page.

            • cisco_nexus1000v_extension.xml


              Note


              To go to your VSM home page, point your browser to the IP address of the active VSM.


          Procedure
            Step 1   Start the vSphere Client.
            Step 2   From the Plug-Ins menu, choose Manage Plug-Ins. The Plug-In Manager dialog box opens.
            Step 3   Right-click the white space within the dialog box, and choose New Plug-In from the popup menu. The Register Plug-In dialog box opens.
            Step 4   Click Browse and choose the cisco_nexus1000v_extension.xml file that you downloaded from the VSM home page.
            Step 5   Click Register Plug-In.
            Step 6   In the Security Warning dialog box, click Ignore to continue using the certificate.
            Step 7   In the Register Plug-in dialog box, click OK. After the plug-in is registered on vCenter, a dialog box appears stating that it has successfully registered.

            Establishing the SVS Connection

            Procedure
              Step 1   Open the vSphere Client.
              Step 2   Choose the primary VSM.
              Figure 1. vSphere Client Window



              Step 3   Choose the Console tab.
              Step 4   Enter the show svs connections command to confirm that there is not an SVS connection.
              Step 5   Open a command window.
              Step 6   In the VSM Console, enter the following command:
              svs connection < Name of the Connection >
                    protocol vmware-vim
                    remote ip address  <VC Ip address >  port  80
                    vmware dvs datacenter-name  <name>
                    max-ports 8192
                    Connect 
              
              Step 7   In the vSphere Console window, enter the show svs connections command.

              The operational status is Connected.


              You have completed establishing the SVS connection.

              Setting Virtual Machine Startup and Shutdown Parameters

              Before You Begin
              • You have the following information:

                • Number of seconds for the default startup delay

                • Number of seconds for the default shutdown delay

              Procedure
                Step 1   In the vSphere Client window, choose a host and click the Configuration tab.
                Step 2   In the Configuration pane, choose Virtual Machine Startup/Shutdown.
                Step 3   In the Virtual Machine Startup and Shutdown pane, click the Properties link.
                Step 4   In the System Settings dialog box, do the following:
                1. Check the Allow virtual machines to start and stop automatically with the system check box.
                2. In the System Settings pane, do the following:
                  • Enter the number of seconds in the Default Startup Delay seconds field.

                  • Enter the number of seconds in the Default Shutdown Delay seconds field.

                3. In the Startup Order pane, do the following:
                  • Choose the VM.

                  • Click the Move Up button until the VM is under Automatic Startup.

                4. Click OK.
                5. Repeat Step 2 through Step 4 for the other VM.

                Startup and shutdown settings are complete.

                Adding VEM Hosts to the Cisco Nexus 1000V Distributed Virtual Switch

                Before You Begin
                • You have the following information:

                  • Physical adapters

                  • Uplink port groups

                Procedure
                  Step 1   In the vSphere Client window, choose Hosts and Clusters > Networking.
                  Figure 2. vSphere Client WIndow



                  Step 2   In the vSphere Client Hosts window, choose the DVS and click the Hosts tab.
                  Figure 3. vSphere Client Hosts Window



                  Step 3   In the Add Hosts to DVS window, right-click the DVS and from the drop-down list, choose Add Host.
                  Figure 4. Add Hosts to DVS



                  Step 4   In the Select Hosts and Physical Adapters screen, choose the hosts and the uplink port groups, and click Next.
                  Step 5   In the Network Connectivity screen, do the following tasks:
                  Note   

                  For Layer 3 communication, you must migrate or create a new Layer 3 vmkernel interface. Migrate your management vmkernel interface into the Layer 3 capable port-profile. Do not use multiple vmkernel interfaces on the same subnet.

                  1. Highlight the vmkernel interface that you want to migrate, and choose the destination port group that you created for management traffic earlier.
                  2. Click Next.
                  Step 6   In the Virtual Machine Networking screen, click Next.
                  Step 7   In the Ready to Complete screen, click Finish.
                  Step 8   In the vSphere Client Hosts window, confirm that the hosts are in the Connected state.

                  The host connection process is complete.

                  Installing the VEM Software Using VUM

                  Before You Begin

                  VMware Update Manager (VUM) automatically selects the correct VEM software to be installed on the host when the host is added to the DVS.


                  Note


                  Make sure that you read the VEM Prerequisites to ensure that the VUM operation proceeds without failure.


                  Installing the VEM Software Using the CLI

                  Based on the version of VMware ESX/ESXi software that is running on the server, there are different installation paths.

                  Installing the VEM Software Locally on a VMware Host Using the CLI


                  Note


                  This procedure applies for VMware 5.0 host and later ESXi versions.
                  Procedure
                    Step 1   Copy the VEM software to the /tmp directory.
                    Step 2   ~ # esxcli software vib install -v /tmp/VIB_FILE

                    Begin the VEM installation procedure.

                    Step 3   Verify that the installation was successful by checking for the “VEM Agent (vemdpa) is running” statement in the output of the vem status -v command.
                    Step 4   Verify that the VIB has installed by entering the following command:

                    esxcli software vib list | grep cisco

                    Step 5   Verify VEM and VSM version by entering the following command:

                    vem show version

                    Step 6   Verify the VSM to check that the module is online by entering the following command:

                    vem vesion -v

                    Step 7   Do one of the following:
                    • If the installation was successful, the installation procedure is complete.

                    • If the installation was not successful, see the "Recreating the Cisco Nexus 1000V Installation" section in the Cisco Nexus 1000V Troubleshooting Guide.


                    The following example shows how to install VEM software locally on a VMware 5.5 host using the CLI.
                    ~ # esxcli software vib install -v /Cisco_bootbank_cisco-vem-v199-5.2.1.3.1.5b.0-3.2.1.vib 
                    Installation Result
                       Message: Operation finished successfully.
                       Reboot Required: false
                       VIBs Installed: Cisco_bootbank_cisco-vem-v199-5.2.1.3.1.5b.0-3.2.1
                       VIBs Removed: Cisco_bootbank_cisco-vem-v198-esx_5.2.1.3.1.5a.0-3.2.1
                       VIBs Skipped:                                   
                    ~ # vem status -v
                    Package vssnet-esxesx2013-release
                    Version 5.2.1.3.1.5b.0-3.2.1
                    Build 1
                    Date Sun Sep 20 08:58:05 PDT 2015
                    
                    VEM modules are loaded
                    
                    Switch Name      Num Ports   Used Ports  Configured Ports  MTU     Uplinks
                    vSwitch0         2432        82          128               1500    vmnic0
                    DVS Name         Num Ports   Used Ports  Configured Ports  MTU     Uplinks
                    cyp              1024        50          1024              1500    vmnic7,vmnic5,vmnic4
                    
                    VEM Agent (vemdpa) is running
                    
                    ~ #
                    
                    ~ # esxcli software vib list | grep cisco
                    cisco-vem-v199-esx             5.2.1.3.1.5b.0-3.2.1                  Cisco   PartnerSupported  2015-09-21
                    ~ #
                    
                    ~ # vemcmd show version
                    VEM Version: 5.2.1.3.1.5b.0-3.2.1
                    VSM Version: 5.2(1)SV3(1.5b)
                    System Version: VMware ESXi 5.5.0 Releasebuild-2068190
                    ESX Version Update Level: 2
                    ~ #
                    

                    Installing the VEM Software on a Stateless ESXi Host

                    The following list outlines the VEM installation process on a stateless ESXi host.

                    Procedure
                      Step 1   See the procedure for Adding the Cisco Nexus 1000V to an ESXi Image Profile.
                      Step 2   Installing the VEM software using one of the two following procedures:
                      Step 3   See the procedure for Configuring Layer 2 Connectivity.

                      Stateless ESXi Host


                      Note


                      For stateless ESXi, the VLAN that you use for the Preboot Execution Environment (gPXE) and Management must be a native VLAN in the Cisco Nexus 1000V management uplink. It must also be a system VLAN on the management VMkernel NIC and on the uplink.


                      VMware vSphere 5.0.0 introduces the VMware Auto Deploy, which provides the infrastructure for loading the ESXi image directly into the host’s memory. The software image of a stateless ESXi is loaded from the Auto Deploy Server after every boot. In this context, the image with which the host boots is identified as the image profile.

                      An image profile is a collection of vSphere Installation Bundles (VIBs) required for the host to operate. The image profile includes base VIBs from VMware and additional VIBs from partners.

                      On a stateless host, you can install or upgrade the VEM software using either the VUM or CLI.

                      In addition, you should bundle the new or modified VEM in the image profile from which the stateless host boots. If it is not bundled in the image profile, the VEM does not persist across reboots of the stateless host.

                      For more information about the VMware Auto Deploy Infrastructure and stateless boot process, see the “Installing ESXi using VMware Auto Deploy” chapter of the vSphere Installation and Setup, vSphere 5.0.0 document.

                      Adding the Cisco Nexus 1000V to an ESXi Image Profile

                      Before You Begin
                      • Install and set up the VMware Auto Deploy Server. See the vSphere Installation and Setup document.

                      • Install the VMware PowerCLI on a Windows platform. This step is required for bundling the VEM into the image profile. For more information, see the vSphere PowerCLI Installation Guide.

                      • On the same Windows platform where VMware PowerCLI is installed, do the following:

                        • Download the image profile offline bundle, which is a ZIP file, to a local file path.

                        • Download the VEM offline bundle, which is a ZIP file, to a local file path.

                      Procedure
                        Step 1   Start the vSphere PowerCLI application.
                        Step 2   Connect to vCenter Server by entering the following command:

                        Connect-VIServer IP_address –User Administrator –Password XXXXX.

                        Step 3   Load the image profile offline bundle by entering the following command:
                        Add-ESXSoftwareDepot image_profile_bundle
                        Note   

                        Each image profile bundle can include multiple image profiles.

                        Step 4   List the image profiles by entering the following command:

                        [vSphere PowerCLI] > Get-EsxImageProfile

                        Step 5   Choose the image profile into which the VEM is to be bundled by entering the following command:

                        New-EsxImageProfile -CloneProfile image_profile_name -Name n1kv-Image

                        Note   

                        The image profiles are in read-only format. You must clone the image profile before adding the VEM into it. The n1kv-Image is the cloned image profile of the ESXi-5.0.0-standard.

                        Step 6   change to Load the Cisco Nexus 1000V offline bundle by entering the following command:

                        Add-EsxSoftwareDepot VEM_bundle

                        Note   

                        The offline bundle is a zip file that includes the n1kv-vib file.

                        Step 7   Confirm that the n1kv-vib package is loaded by entering the following command:

                        Get-EsxSoftwarePackage -Name cisco*

                        Step 8   Bundle the n1kv-package into the cloned image profile by entering the following command:

                        Add-EsxSoftwarePackage -ImageProfile n1kv-Image -SoftwarePackage n1kv_package_name

                        Step 9  

                        List all the VIBs into the cloned image profile by entering the following command:

                        1. $img = Get-EsxImageProfile n1kv-Image
                        2. $img.vibList
                        Step 10   Export the image profile to a depot file for future use by entering the following command:

                        Export-EsxImageProfile –ImageProfile n1kv-Image –FilePath C:\n1kv-Image.zip –ExportToBundle

                        Step 11  

                        Set up the rule for the host to bott with the image profile by entering the following commands

                        Note   

                        Any of the host parameters, such as the MAC address, IPV4 IP address, or domain name, can be used to associate an image profile with the host.

                        1. New-deployrule -item $img -name rule-test –Pattern “mac=00:50:56:b6:03:c1”
                        2. Add-DeployRule -DeployRule rule-test
                        Step 12   Display the configured rule to make sure that the correct image profile is associated with the host by entering the following command:

                        Get-DeployRuleSet

                        Step 13   Reboot the host.

                        The host contacts the Auto-Deploy Server and presents the host boot parameters. The Auto Deploy server checks the rules to find the image profile associated with this host and loads the image to the host’s memory. The host boots from the image.


                        This example shows how to add the Cisco Nexus 1000V to an ESXi image profile:


                        Note


                        The examples in the procedure may contain Cisco Nexus 1000V versions and filenames that are not relevant to your release. Refer to the Cisco Nexus 1000V and VMware Compatibility Information for your specific versions and filenames.


                        vSphere PowerCLI> Set-ExecutionPolicy unrestricted
                        
                        Execution Policy Change
                        The execution policy helps protect you from scripts that you do not trust.
                        Changing the execution policy might expose you to the security risks described
                        in the about_Execution_Policies help topic. Do you want to change the execution
                         policy?
                        [Y] Yes  [N] No  [S] Suspend  [?] Help (default is "Y"): Y
                        vSphere PowerCLI>  Connect-VIServer 10.105.231.40 -User administrator -Password 'xxxxxxxx'
                        
                        Working with multiple default servers?
                        
                            Select [Y] if you want to work with more than one default servers. In this
                        case, every time when you connect to a different server using Connect-VIServer,
                         the new server connection is stored in an array variable together with the
                        previously connected servers. When you run a cmdlet and the target servers
                        cannot be determined from the specified parameters, the cmdlet runs against all
                         servers stored in the array variable.
                            Select [N] if you want to work with a single default server. In this case,
                        when you run a cmdlet and the target servers cannot be determined from the
                        specified parameters, the cmdlet runs against the last connected server.
                        
                            WARNING: WORKING WITH MULTIPLE DEFAULT SERVERS WILL BE ENABLED BY DEFAULT
                        IN A FUTURE RELEASE. You can explicitly set your own preference at any time by
                        using the DefaultServerMode parameter of Set-PowerCLIConfiguration.
                        
                        [Y] Yes  [N] No  [S] Suspend  [?] Help (default is "Y"): Y
                        
                        Name                           Port  User
                        ----                           ----  ----
                        10.105.231.40                  443   administrator
                        
                        
                        vSphere PowerCLI> Add-EsxSoftwareDepot 'C:\Documents and Settings\Administrator\Desktop\upgrade\229\VEM550-201509199113-BG-release.zip'
                        
                        Depot Url
                        ---------
                        zip:C:\Documents and Settings\Administrator\Desktop\upgrade\229\VMware-ESXi-...
                        
                        
                        vSphere PowerCLI>  Get-EsxImageProfile
                        
                        Name                           Vendor          Last Modified   Acceptance Level
                        ----                           ------          -------------   ----------------
                        ESXi-5.1.0-20121201001s-no-... VMware, Inc.    12/7/2012 7:... PartnerSupported
                        CN1-CY                         CISCO           4/22/2013 11... PartnerSupported
                        ESXi-5.1.0-20121204001-stan... VMware, Inc.    12/7/2012 7:... PartnerSupported
                        ESXi-5.1.0-20121201001s-sta... VMware, Inc.    12/7/2012 7:... PartnerSupported
                        ESXi-5.1.0-799733-no-tools     VMware, Inc.    8/12/2015 3:0... PartnerSupported
                        ESXi-5.1.0-20121204001-no-t... VMware, Inc.    12/7/2012 7:... PartnerSupported
                        ESXi-5.1.0-799733-standard     VMware, Inc.    8/12/2015 3:0... PartnerSupported
                        
                        
                        vSphere PowerCLI> New-EsxImageProfile -CloneProfile ESXi-5.1.0-799733-standard -Name FINAL
                        
                        cmdlet New-EsxImageProfile at command pipeline position 1
                        Supply values for the following parameters:
                        (Type !? for Help.)
                        Vendor: CISCO
                        
                        Name                           Vendor          Last Modified   Acceptance Level
                        ----                           ------          -------------   ----------------
                        FINAL                          CISCO           8/12/2015 3:0... PartnerSupported
                        
                        
                        vSphere PowerCLI> Add-EsxSoftwareDepot 'C:\Documents and Settings\Administrator\Desktop\upgrade\229\VEM550-201509199113-BG-release.zip
                        Depot Url
                        ---------
                        zip:C:\Documents and Settings\Administrator\Desktop\upgrade\229\cisco-vem-v1...
                        
                        
                        vSphere PowerCLI> Get-EsxSoftwarePackage cisco*
                        
                        Name                     Version                        Vendor     				Creation Date
                        ----                     -------                        ------     				------------
                        cisco-vem-v199-esx    5.2.1.3.1.5b.0-3.2.1      Cisco PartnerSupported  2015-02-04
                        
                        
                        
                        vSphere PowerCLI> Add-EsxSoftwarePackage -SoftwarePackage cisco-vem-v198-esx -ImageProfile FINAL
                        
                        Name                           Vendor          Last Modified   Acceptance Level
                        ----                           ------          -------------   ----------------
                        FINAL                          CISCO           8/14/2015 3:... PartnerSupported
                        
                        
                        vSphere PowerCLI> $img = Get-EsxImageProfile FINAL
                        
                        
                        Name                     Version                        Vendor     Creation Date
                        ----                     -------                        ------     ------------
                        scsi-bnx2i               1.9.1d.v50.1-5vmw.510.0.0.7... VMware     8/12/2015 ...
                        sata-sata-promise        2.12-3vmw.510.0.0.799733       VMware     8/12/2015 ...
                        net-forcedeth            0.61-2vmw.510.0.0.799733       VMware     8/12/2015 ...
                        esx-xserver              5.1.0-0.0.799733               VMware     8/12/2015 ...
                        misc-cnic-register       1.1-1vmw.510.0.0.799733        VMware     8/12/2015 ...
                        net-tg3                  3.110h.v50.4-4vmw.510.0.0.7... VMware     8/12/2015 ...
                        scsi-megaraid-sas        5.34-4vmw.510.0.0.799733       VMware     8/12/2015 ...
                        scsi-megaraid-mbox       2.20.5.1-6vmw.510.0.0.799733   VMware     8/12/2015 ...
                        scsi-ips                 7.12.05-4vmw.510.0.0.799733    VMware     8/12/2015 ...
                        net-e1000e               1.1.2-3vmw.510.0.0.799733      VMware     8/12/2015 ...
                        sata-ahci                3.0-13vmw.510.0.0.799733       VMware     8/12/2015 ...
                        sata-sata-svw            2.3-3vmw.510.0.0.799733        VMware     8/12/2015 ...
                        net-cnic                 1.10.2j.v50.7-3vmw.510.0.0.... VMware     8/12/2015 ...
                        net-e1000                8.0.3.1-2vmw.510.0.0.799733    VMware     8/12/2015 ...
                        ata-pata-serverworks     0.4.3-3vmw.510.0.0.799733      VMware     8/12/2015 ...
                        scsi-mptspi              4.23.01.00-6vmw.510.0.0.799733 VMware     8/12/2015 ...
                        ata-pata-hpt3x2n         0.3.4-3vmw.510.0.0.799733      VMware     8/12/2015 ...
                        net-s2io                 2.1.4.13427-3vmw.510.0.0.79... VMware     8/12/2015 ...
                        esx-base                 5.1.0-0.0.799733               VMware     8/12/2015 ...
                        net-vmxnet3              1.1.3.0-3vmw.510.0.0.799733    VMware     8/12/2015 ...
                        net-bnx2                 2.0.15g.v50.11-7vmw.510.0.0... VMware     8/12/2015 ...
                        cisco-vem-v171-esx       5.2.1.3.1.2.0-3.2.2            Cisco      8/12/2015 ...
                        scsi-megaraid2           2.00.4-9vmw.510.0.0.799733     VMware     8/12/2015 ...
                        ata-pata-amd             0.3.10-3vmw.510.0.0.799733     VMware     8/12/2015 ...
                        ipmi-ipmi-si-drv         39.1-4vmw.510.0.0.799733       VMware     8/12/2015 ...
                        scsi-lpfc820             8.2.3.1-127vmw.510.0.0.799733  VMware     8/12/2015 ...
                        ata-pata-atiixp          0.4.6-4vmw.510.0.0.799733      VMware     8/12/2015 ...
                        esx-dvfilter-generic-... 5.1.0-0.0.799733               VMware     8/12/2015 ...
                        net-sky2                 1.20-2vmw.510.0.0.799733       VMware     8/12/2015 ...
                        scsi-qla2xxx             902.k1.1-9vmw.510.0.0.799733   VMware     8/12/2015 ...
                        net-r8169                6.011.00-2vmw.510.0.0.799733   VMware     8/12/2015 ...
                        sata-sata-sil            2.3-4vmw.510.0.0.799733        VMware     8/12/2015 ...
                        scsi-mpt2sas             10.00.00.00-5vmw.510.0.0.79... VMware     8/12/2015 ...
                        sata-ata-piix            2.12-6vmw.510.0.0.799733       VMware     8/12/2015 ...
                        scsi-hpsa                5.0.0-21vmw.510.0.0.799733     VMware     8/12/2015 ...
                        ata-pata-via             0.3.3-2vmw.510.0.0.799733      VMware     8/12/2015 ...
                        scsi-aacraid             1.1.5.1-9vmw.510.0.0.799733    VMware     8/12/2015 ...
                        scsi-rste                2.0.2.0088-1vmw.510.0.0.799733 VMware     8/12/2015 ...
                        ata-pata-cmd64x          0.2.5-3vmw.510.0.0.799733      VMware     8/12/2015 ...
                        ima-qla4xxx              2.01.31-1vmw.510.0.0.799733    VMware     8/12/2015 ...
                        net-igb                  2.1.11.1-3vmw.510.0.0.799733   VMware     8/12/2015 ...
                        scsi-qla4xxx             5.01.03.2-4vmw.510.0.0.799733  VMware     8/12/2015 ...
                        block-cciss              3.6.14-10vmw.510.0.0.799733    VMware     8/12/2015 ...
                        scsi-aic79xx             3.1-5vmw.510.0.0.799733        VMware     8/12/2015 ...
                        tools-light              5.1.0-0.0.799733               VMware     8/12/2015 ...
                        uhci-usb-uhci            1.0-3vmw.510.0.0.799733        VMware     8/12/2015 ...
                        sata-sata-nv             3.5-4vmw.510.0.0.799733        VMware     8/12/2015 ...
                        sata-sata-sil24          1.1-1vmw.510.0.0.799733        VMware     8/12/2015 ...
                        net-ixgbe                3.7.13.6iov-10vmw.510.0.0.7... VMware     8/12/2015 ...
                        ipmi-ipmi-msghandler     39.1-4vmw.510.0.0.799733       VMware     8/12/2015 ...
                        scsi-adp94xx             1.0.8.12-6vmw.510.0.0.799733   VMware     8/12/2015 ...
                        scsi-fnic                1.5.0.3-1vmw.510.0.0.799733    VMware     8/12/2015 ...
                        ata-pata-pdc2027x        1.0-3vmw.510.0.0.799733        VMware     8/12/2015 ...
                        misc-drivers             5.1.0-0.0.799733               VMware     8/12/2015 ...
                        net-enic                 1.4.2.15a-1vmw.510.0.0.799733  VMware     8/12/2015 ...
                        net-be2net               4.1.255.11-1vmw.510.0.0.799733 VMware     8/12/2015 ...
                        net-nx-nic               4.0.558-3vmw.510.0.0.799733    VMware     8/12/2015 ...
                        esx-xlibs                5.1.0-0.0.799733               VMware     8/12/2015 ...
                        net-bnx2x                1.61.15.v50.3-1vmw.510.0.0.... VMware     8/12/2015 ...
                        ehci-ehci-hcd            1.0-3vmw.510.0.0.799733        VMware     8/12/2015 ...
                        ohci-usb-ohci            1.0-3vmw.510.0.0.799733        VMware     8/12/2015 ...
                        net-r8168                8.013.00-3vmw.510.0.0.799733   VMware     8/12/2015 ...
                        esx-tboot                5.1.0-0.0.799733               VMware     8/12/2015 ...
                        ata-pata-sil680          0.4.8-3vmw.510.0.0.799733      VMware     8/12/2015 ...
                        ipmi-ipmi-devintf        39.1-4vmw.510.0.0.799733       VMware     8/12/2015 ...
                        scsi-mptsas              4.23.01.00-6vmw.510.0.0.799733 VMware     8/12/2015 ...
                        
                        
                        
                        vSphere PowerCLI> Export-EsxImageProfile -ImageProfile FINAL -FilePath 'C:\Documents and Settings\Administrator\Desktop\FINAL.zip' -ExportToBundle
                        vSphere PowerCLI>  New-deployrule -item $img -name rule-test –Pattern “mac=00:50:16:26:13:c2”
                        vSphere PowerCLI] > Add-DeployRule -DeployRule rule-test
                        [vSphere PowerCLI] > Get-DeployRuleSet
                        Name : rule-test
                        PatternList : {mac=00:50:16:26:13:c2}
                        ItemList : {FINAL}
                        

                        Installing the VEM Software on a Stateless ESXi Host Using esxcli

                        Before You Begin
                        • When you enter the esxcli software vib install command on an ESXi 5.0.0 host, note that the following message appears:

                          Message: WARNING: Only live system was updated, the change is not persistent.

                        Procedure
                          Step 1  

                          Display the VMware version and build number by entering the following commands:

                          • vmware -v
                          • vmware -l
                          Step 2   Log in to the ESXi stateless host.
                          Step 3   Copy the offline bundle to the host by entering the the following command:
                          esxcli software vib install -d file_path/offline_bundle
                          Note   

                          If the host is an ESXi 5.0.0 stateful host, the “Message: Operation finished successfully” line appears.

                          Step 4   Verify that the VIB has installed by entering the following command:

                          esxcli software vib list | grep cisco

                          Step 5   Change to Check that the VEM agent is running by entering the following command:

                          vem status -v

                          Step 6   Display the VEM version, VSM version, and ESXi version by entering the following command:

                          vemcmd show version

                          Step 7   Display the ESXi version and details about passthrough NICs by entering the following command:

                          vem version -v

                          Step 8   Add the host to the DVS by using the vCenter Server.
                          Step 9   On the VSM, verify that the VEM software has been installed by entering the following command:

                          show module


                          This example shows how to install VEM software on a stateless host using esxcli.

                          Note


                          The examples in the procedure may contain Cisco Nexus 1000V versions and filenames that are not relevant to your release. Refer to the Cisco Nexus 1000V and VMware Compatibility Information for your specific versions and filenames.


                          ~ # vmware -v
                          VMware ESXi 5.5.0 build-2068190
                          ~ #
                          ~ # vmware -l
                          VMware ESXi 5.5.0 Update 2
                          
                          ~ # esxcli software vib install –d /vmfs/volumes/newnfs/MN-VEM/VEM550-201509199113-BG-release.zip
                          Installation Result
                          Message: WARNING: Only live system was updated, the change is not persistent.
                          Reboot Required: false
                          VIBs Installed: Cisco_bootbank_cisco-vem-v199-esx_5.2.1.3.1.5b.0-3.2.1
                          VIBs Removed:
                          VIBs Skipped:
                          
                          ~ # esxcli software vib list | grep cisco
                          cisco-vem-v199-esx             5.2.1.3.1.5b.0-3.2.1                  Cisco   PartnerSupported  2015-09-21
                          ~ #
                          ~ # vem status -v
                          Package vssnet-esxesx2013-release
                          Version 5.2.1.3.1.5b.0-3.2.1
                          Build 1
                          Date Sun Sep 20 08:58:05 PDT 2015
                          
                          VEM modules are loaded
                          
                          Switch Name      Num Ports   Used Ports  Configured Ports  MTU     Uplinks
                          vSwitch0         2432        82          128               1500    vmnic0
                          DVS Name         Num Ports   Used Ports  Configured Ports  MTU     Uplinks
                          cyp              1024        50          1024              1500    vmnic7,vmnic5,vmnic4
                          
                          VEM Agent (vemdpa) is running
                          
                          ~ # vemcmd show version
                          
                          VEM Version: 5.2.1.3.1.5b.0-3.2.1
                          VSM Version: 5.2(1)SV3(1.5b)
                          System Version: VMware ESXi 5.5.0 Releasebuild-2068190
                          ESX Version Update Level: 2
                          ~ #
                          ~ #
                          
                          
                          ~(config)# show module 
                          
                          Mod  Ports  Module-Type                       Model               Status
                          ---  -----  --------------------------------  ------------------  ------------
                          1    0      Virtual Supervisor Module         Nexus1000V          ha-standby
                          2    0      Virtual Supervisor Module         Nexus1000V          active *
                          4    1022   Virtual Ethernet Module           NA                  ok
                          5    1022   Virtual Ethernet Module           NA                  ok
                          12   1022   Virtual Ethernet Module           NA                  ok
                          15   1022   Virtual Ethernet Module           NA                  ok
                          
                          
                          Mod  Sw                  Hw
                          ---  ------------------  ------------------------------------------------
                          1    5.2(1)SV3(1.5b)     0.0
                          2    5.2(1)SV3(1.5b)     0.0
                          4    5.2(1)SV3(1.5b)     VMware ESXi 6.0.0 Releasebuild-2494585 (6.0)
                          5    5.2(1)SV3(1.5b)     VMware ESXi 5.5.0 Releasebuild-2068190 (3.2)
                          12   5.2(1)SV3(1.5b)     VMware ESXi 5.5.0 Releasebuild-2068190 (3.2)
                          15   5.2(1)SV3(1.5b)     VMware ESXi 5.1.0 Releasebuild-2323236 (3.1)
                          
                          
                          Mod  Server-IP        Server-UUID                           Server-Name
                          ---  ---------------  ------------------------------------  --------------------
                          1    10.197.133.108   NA                                    NA
                          2    10.197.133.108   NA                                    NA
                          4    10.197.132.43    e6c1a563-bc9e-11e0-bd1d-30e4dbc2baba  NA
                          5    10.197.132.42    e0829a21-bc61-11e0-bd1d-30e4dbc2ba66  10.197.132.42
                          12   10.197.132.46    db8b80ac-af1d-11e0-a4e7-30e4dbc26b82  10.197.132.46
                          15   10.197.132.44    7b1a5e63-bcd0-11e0-bd1d-30e4dbc2c3ae  10.197.132.44
                          
                          * this terminal session
                          
                          ~#
                          
                          

                          Installing the VEM Software on a Stateless ESXi Host Using VUM

                          Before You Begin
                          • Make sure that the VUM patch repository has the VEM software downloaded.

                          Procedure
                            Step 1   In vCenter Server, choose Home > Update Manager > Configuration > ESX host/Cluster settings.

                            The ESX Host/Cluster Settings window opens.

                            Step 2   Check the PXE Booted ESXi Host Settings check box.
                            Figure 5. ESX Host/Cluster Settings Window



                            Step 3   Add the host to the DVS by using vCenter Server.

                            Installing a VSM on the Cisco Nexus Cloud Services Platform

                            You can install the VSM on the Cisco Nexus Cloud Services Platform and move from Layer 2 to Layer 3 connectivity.


                            Note


                            VEMs do not register to the VSM before a vmkernel interface (vmk) is migrated to a Layer 3 control-capable port profile. You must migrate a vmk to the Layer 3 port profile after migrating host vmnics to Ethernet port profiles.

                            The example may contain Cisco Nexus 1000V versions and filenames that are not relevant to your release. Refer to the Cisco Nexus 1000V and VMware Compatibility Information for your specific versions and filenames.


                            Before You Begin

                            Copy the OVA file to the bootflash:repository/ of the Cisco Nexus Cloud Services Platform.

                            Procedure
                              Step 1   Create a virtual service blade.

                              switch(config)# show virtual-service-blade summary 
                              
                              ---------------------------------------------------------------------------------
                              Name        HA-Role       HA-Status     Status               Location
                              ---------------------------------------------------------------------------------
                              switch(config)# virtual-service-blade vsm-1 
                              switch(config-vsb-config)# virtual-service-blade-type new  n1000v-dk9.5.2.1.SV3.1.5b.1010.ova 
                              switch(config-vsb-config)# show virtual-service-blade summary 
                              
                              --------------------------------------------------------------------------------------
                              Name        HA-Role       HA-Status     Status                   Location
                              --------------------------------------------------------------------------------------
                              vsm-1       PRIMARY       NONE          VSB NOT PRESENT          PRIMARY
                              vsm-1       SECONDARY     NONE          VSB NOT PRESENT          SECONDARY
                              
                              switch(config-vsb-config)#
                              
                              Step 2   Configure the control, packet, and management interface VLANs for static and flexible topologies.

                              switch(config-vsb-config)# interface management vlan 100 
                              switch(config-vsb-config)# interface control vlan 101 
                              switch(config-vsb-config)# interface packet vlan 101
                               
                              Step 3   Configure the Cisco Nexus 1000V on the Cisco Nexus 1010.

                              switch(config-vsb-config)# enable 
                              Enter vsb image:  [n1000v-dk9.5.2.1.SV3.1.5b.1010.ova]
                              Enter domain id[1-1023]: 127 
                              Enter SVS Control mode (L2 / L3): [L3] L2
                              Management IP version [V4/V6]: [V4] 
                              Enter Management IP address: 192.0.2.79 
                              Enter Management subnet mask: 255.255.255.0 
                              IPv4 address of the default gateway: 192.0.2.1 
                              Enter HostName: n1000v 
                              Enter the password for ‘admin’: ********
                              Note: VSB installation is in progress, please use show virtual-service-blade commands to check the installation status.
                              switch(config-vsb-config)# 
                              
                              
                              Step 4   Display the primary and secondary VSM status.

                              switch(config-vsb-config)# show virtual-service-blade summary 
                              
                              --------------------------------------------------------------------------------------
                              Name        HA-Role       HA-Status     Status                   Location
                              --------------------------------------------------------------------------------------
                              vsm-1       PRIMARY       NONE          VSB POWER ON IN PROGRESS PRIMARY
                              vsm-1       SECONDARY     ACTIVE        VSB POWERED ON           SECONDARY
                              
                              
                              Step 5   Log in to the VSM.

                              switch(config)# virtual-service-blade vsm-1 
                              switch(config-vsb-config)# login virtual-service-blade vsm-1
                              Telnet escape character is ‘^\’.
                              Trying 192.0.2.18...
                              Connected to 192.0.2.18.
                              Escape character is ‘^\’.
                              
                              Nexus 1000v Switch
                              n1000v login: admin
                              Password:
                              Cisco Nexus operating System (NX-OS) Software 
                              TAC support: http://www/cisco.com/tac 
                              Copyright (c) 2002-2015, Cisco Systems, Inc. All rights reserved. 
                              The copyrights to certain works contained in this software are 
                              owned by other third parties and used and distributed under 
                              license. Certain components of this software are licensed under 
                              the GNU General Public License (GPL) version 2.0 or the GNU 
                              Lesser General Public License (LGPL) Version 2.1. A copy of each 
                              such license is available at 
                              http://www.opensource.org/licenses/gpl-2.0.php and 
                              http://www.opensource.org/licenses/lgpl-2.1.php 
                              switch#
                              
                              
                              Step 6   Change svs mode from Layer 2 to Layer 3 in the Cisco Nexus 1000V.
                              Note   

                              The configuration in the highlighted code is optional.

                              switch(config)# svs-domain 
                              switch(config-svs-domain)# no control vlan 
                              Warning: Config saved but not pushed to vCenter Server due to inactive connection! 
                              switch(config-svs-domain)# no packet vlan 
                              Warning: Config saved but not pushed to vCenter Server due to inactive connection! 
                              switch(config-svs-domain)# svs mode L3 interface mgmt0 
                              Warning: Config saved but not pushed to vCenter Server due to inactive connection! 
                              switch(config-svs-domain)# show svs domain 
                              switch(config-svs-domain)# show svs domain
                              SVS domain config
                              Domain id: 101
                              Control vlan: NA
                              Packet vlan:  NA
                              L2/L3 Control mode: L3
                              L3 control interface: mgmt0
                              Status: Config push to VC successful.
                              switch(config-svs-domain)#
                              
                              

                              Feature History for Installing the Cisco Nexus 1000V

                              The following table lists the release history for installing the Cisco Nexus 1000V.

                              Feature Name

                              Releases

                              Feature Information

                              VEM Installation 5.1

                              4.2(1)SV2(2.1)

                              Installing VEM software remotely or locally on a VMware 5.1 host using the CLI is now supported.

                              Standard and Custom installation application

                              4.2(1)SV2(1.1)

                              Installation Application updated with a Standard and Custom version

                              Updated installation application

                              4.2(1)SV1(5.2)

                              Added screens to the Java application.

                              VSM and VEM Installation

                              4.2(1)SV1(5.1)

                              Java applications introduced for VSM and VEM installation.

                              Installing the Cisco Nexus 1000V

                              4.0(1)SV1(1)

                              Introduced in this release.