Upgrading the Cisco Nexus 1000V

This chapter contains the following sections:

Information About the Software Upgrade

Upgrade Software Sources


Note


An interactive upgrade tool has been provided to assist you in determining the correct upgrade steps based on your current environment and the one to which you want to upgrade.


You can obtain your upgrade-related software from the following sources listed in this table:

Table 1 Obtaining the Upgrade Software

Source

Description

Cisco

Download the current release of the Cisco Nexus 1000V software from http:/​/​www.cisco.com/​en/​US/​products/​ps9902/​index.html.

VMware

Download the VMware software from the VMware website.

The current Cisco Nexus 1000V software release image for VMware Release 5.1 is at the VMware web site:

For information about your software and platform compatibility, see the Cisco Nexus 1000V and VMware Compatibility Information document.

Information about NetFlow Upgrade

With Distributed NetFlow, the switch sends NetFlow export packets directly from the VEMs to the collectors.

During the upgrade process, the switch migrates from the old centralized model to the new distributed model. As part of this migration, unsupported commands are removed and/or converted as part of the VSM upgrade. The new and changed commands are available as soon as all of the VEMs are upgraded and the feature level is updated. Additionally, the following new requirements are imposed on the network reachability:
  • The collectors must be Layer 3 reachable from at least one vmknic on each VEM host.

  • Strict Reverse Path Forwarding (RPF) might need to be disabled on the routers between the VEM hosts and the collectors.

These are the removed, converted, and new commands:
Command Change

cache size

Removed.

The cache size is no longer user configurable.

timeout active

timeout inactive

Converted.

The configured timeout active and timeout inactive values are consolidated and converted to be the flow timeout active and flow timeout inactive values. The new consolidated timeouts are set to the maximum of the old individual timeouts.
Note   

After conversion, subsequent changes to the timeouts do not apply to the existing interface configurations on non-upgraded VEMs.

source mgmt

Converted.

The configured source mgmt values are converted to be the source lc-exp values. The NetFlow export packets are no longer sent from the VSM’s mgmt0 interface.

netflow layer2-switched input

New.

The netflow layer2-switched input command configures the Layer 2 default record.

match datalink

New.

The match datalink command configures the Layer 2 record fields.

Prerequisites for the Upgrade

Before You Begin

Review the following information before you begin an upgrade:

  • Virtual machine hardware version 11 is not supported.

  • The Virtual Service Domain (VSD) feature is no longer supported and must be removed before upgrading to Release 5.2(1)SV3(1.4).

  • The Upgrade Application cannot be used for the direct upgrade of the Virtual Supervisor Module(VSMs) from Releases 4.2(1)SV1(4), 4.2(1)SV1(5.1), 4.2(1)SV1(5.2), 5.2(1)SV3(1.2), and 5.2(1)SV3(1.3) to the current release.

  • A pair of VSMs in a high availability (HA) pair is required in order to support a nondisruptive upgrade.

  • A system with a single VSM can only be upgraded in a disruptive manner.

  • The network and server administrators must coordinate the upgrade procedure with each other.

  • The upgrade process is irrevocable. After the software is upgraded, you can downgrade by removing the current installation and reinstalling the software. For more information, see the “Recreating the Installation” section of the Cisco Nexus 1000V Troubleshooting Guide.

  • A combined upgrade of ESX and the Virtual Ethernet Module (VEM) in a single maintenance mode is supported in this release. A combined upgrade requires at least vCenter 5.0 Update 1 whether you upgrade manually or are using the VMware Update Manager.

  • You can manually upgrade the ESX and VEM in one maintenance mode as follows:
    1. Place the host in maintenance mode.

    2. Upgrade ESX to 5.0 or 5.1 as needed.

    3. Install the VEM vSphere Installation Bundle (VIB) while the host is still in maintenance mode.

    4. Remove the host from maintenance mode.

  • The steps for the manual combined upgrade procedure do not apply for VMware Update Manager (VUM)-based upgrades.

  • You can abort the upgrade procedure by pressing Ctrl-C.

Prerequisites for Upgrading VSMs

Upgrading VSMs has the following prerequisites:

  • Close any active configuration sessions before upgrading the Cisco Nexus 1000V software.

  • Save all changes in the running configuration to the startup configuration.

  • Save a backup copy of the running configuration in external storage.

  • Perform a VSM backup. For more information, see the “Configuring VSM Backup and Recovery” chapter in the Cisco Nexus 1000V System Management Configuration Guide.

  • Use the VSM management IP address to log into VSM and perform management tasks.

    Important:

    If you connect to a VSM using the VSA serial port or the connect host from the Cisco Integrated Management Control (CIMC), do not initiate commands that are CPU intensive, such as copying image from the TFTP server to bootflash or generating a lot of screen output or updates. Use the VSA serial connections, including CIMC, only for operations such as debugging or basic configuration of the VSA.

Prerequisite to Upgrading a VSM to a 3-GB Hard Disk Drive

Cisco Nexus 1000V for VMware Release 5.2(1)SV3(1.x) and higher requires a minimum of 3-GB of hard disk drive (HDD) space. If you are upgrading from a previous release to Release 5.2(1)SV3(1.x) and you have a 2-GB HDD, you must upgrade to a 3-GB HDD.

Upgrading Hard Disk Drive Space from 2 GB to 3 GB on a VSM as a VM

We recommend that you upgrade the hard disk drive (HDD) space from 2 GB to 3 GB on a VSM VM before upgrading VSM to Release 5.2(1)SV3(1.1) or later.

Before You Begin

Make sure that the Cisco Nexus 1000V VSMs are running Release 4.2(1)SV2(1.1) or 4.2(1)SV2(2.1).

Make sure that the existing Cisco Nexus 1000V VSMs are an HA pair with 2 GB HDD.

Procedure
    Step 1   Remove the existing standby VSM.
    1. Right-click on the VSM VM and power off the VM.
    2. Remove it from the Virtual Center inventory.
    Step 2   Bring up the new standby VSM VM (with 3-GB HDD) with the same release as the active VSM using ISO.

    For example, if the active VSM is running Release 4.2(1)SV2(1.1), bring up the new standby VSM with Release 4.2(1)SV2(1.1).

    1. Confirm that the same port profiles are used as the primary VSM for 3 network interfaces.
    2. Provision a 3-GB HDD with a minimum of 2 GB of RAM reserved and allocated, and has a minimum CPU speed of 1600 MHz.

    See Installing the Software from the ISO Image for more information.

    Step 3   Power on the standby VSM.
    1. Confirm the HA role is set as Secondary.
    2. Configure the Domain ID is the same as the Primary VSM.
    Step 4   After the HA pair is formed, perform a system switchover to make the standby VSM become the active VSM.
    Step 5   Remove the current standby VSM.
    1. Right-click on the VSM VM and power off the VM.
    2. Remove it from the Virtual Center inventory.
    Step 6   Change the Active VSM system redundancy role to Primary system by entering system redundancy role primary.
    Step 7   Copy the config to start-up and perform a reload.
    Step 8   Verify the current role by entering show system redundancy status. Role should be set as Primary.
    Step 9   Bring up the new standby VSM VM (with 3-GB HDD) using ISO following Step 2 and Step 3.
    Step 10   After the HA pair is formed, verify it by entering show system internal flash. It should reflect the VSM with 3-GB HDD.

    What to Do Next

    Perform an in-service software upgrade (ISSU) to Release 5.2(1)SV3(1.1) or later.

    Upgrading Hard Disk Drive Space from 2 GB to 3 GB on a VSM on a VSB

    We recommend that you upgrade the VSM that is deployed on a CSP from a 2-GB hard disk drive (HDD) to a 3-GB HDD.

    Procedure
      Step 1   Identify the standby VSM by entering the show virtual-service-blade summary command.
      N1110# show virtual-service-blade summary
      
      Name                    HA-Role     HA-Status     Status                Location
      -------------------------------------------------------------------------------
      switch                  PRIMARY     ACTIVE      VSB POWERED ON           PRIMARY
      switch                  SECONDARY   STANDBY     VSB POWERED ON           SECONDARY
      
      N1110#

      The output shows that the standby VSM is running on the secondary Cisco Nexus 1010 Virtual Service Blade (VSB).

      Step 2   Shut down and delete the standby VSM on the secondary VSB.
      1. N1110# configure terminal
      2. N1110#(config)virtual-service-blade name switch
      3. N1110#(config-vsb-config)shutdown secondary
      4. N1110#(config-vsb-config)no enable secondary
      Step 3   Bring up the new secondary VSB with Release 4.2(1)SV2(1.1) using ISO. See the Cisco Nexus 1100 Series Virtual Services Appliances Deployment Guide White Paper for more information.
      Step 4   Change the disk size to 3 GB or more.
      N1110(config-vsb-config)# disksize 4
      
      Step 5   Enable the standby VSM on the secondary VSB. See the Cisco Nexus 1100 Series Virtual Services Appliances Deployment Guide White Paper for more information.
      N1110# sh virtual-service-blade summary
      
      -------------------------------------------------------------------------------
      Name                    HA-Role     HA-Status   Status                   Location
      -------------------------------------------------------------------------------
      switch                  PRIMARY     ACTIVE      VSB POWERED ON           PRIMARY
      switch                  SECONDARY   NONE        VSB NOT PRESENT          SECONDARY
      switch1                 PRIMARY     NONE        VSB NOT PRESENT          PRIMARY
      switch1                 SECONDARY   STANDBY     VSB POWERED ON           SECONDARY
      
      N1110#
      Step 6   Perform a system switchover to make the active VSM on the primary VSB become the standby VSM. To do this, enter the system switchover command on the active VSM.
      N1110# system switchover
      N1110(config-vsb-config)# show virtual-service-blade summary
      
      -------------------------------------------------------------------------------
      Name                 HA-Role     HA-Status   Status                   Location
      -------------------------------------------------------------------------------
      switch                  PRIMARY     STANDBY     VSB POWERED ON           PRIMARY
      switch                  SECONDARY   NONE        VSB NOT PRESENT          SECONDARY
      switch1                 PRIMARY     NONE        VSB NOT PRESENT          PRIMARY
      switch1                 SECONDARY   ACTIVE      VSB POWERED ON           SECONDARY
      
      N1110(config-vsb-config#
      Step 7   After the HA pair is formed, shutdown and delete the standby VSM on the primary VSB.
      N1110(config)# virtual-service-blade switch
      N1110(config-vsb-config)# shutdown primary
      N1110(config-vsb-config)# no enable primary
      
      N1110(config-vsb-config)# show virtual-service-blade summary
      
      -------------------------------------------------------------------------------
      Name                HA-Role     HA-Status   Status                   Location
      -------------------------------------------------------------------------------
      switch                  PRIMARY     NONE        VSB NOT PRESENT          PRIMARY
      switch                  SECONDARY   NONE        VSB NOT PRESENT          SECONDARY
      switch1                 PRIMARY     NONE        VSB NOT PRESENT          PRIMARY
      switch1                 SECONDARY   ACTIVE      VSB POWERED ON           SECONDARY
      
      N1110(config-vsb-config)#
      
      Step 8   Bring up the new VSB with Release 4.2(2)SV2(1.1) using ISO. See the Cisco Nexus 1100 Series Virtual Services Appliances Deployment Guide White Paper for more information.
      Step 9   Enable the primary VSM. See the Cisco Nexus 1100 Series Virtual Services Appliances Deployment Guide White Paper for more information.
      N1110(config)# show virtual-service-blade summary
      
      -------------------------------------------------------------------------------
      Name                    HA-Role     HA-Status   Status                   Location
      -------------------------------------------------------------------------------
      switch                  PRIMARY     NONE        VSB NOT PRESENT          PRIMARY
      switch                  SECONDARY   NONE        VSB NOT PRESENT          SECONDARY
      switch1                 PRIMARY     STANDBY     VSB POWERED ON           PRIMARY
      switch1                 SECONDARY   ACTIVE      VSB POWERED ON           SECONDARY
      
      N1110(config-vsb-config)#
      
      Step 10   Verify that the HDD size has changed. The following example shows that the HDD size is 4 GB.
      N1110(config)# show system internal flash
      
      Mount-on                  1K-blocks      Used   Available   Use%  Filesystem
              /                            307200     87628      219572     29   /dev/root
              /proc                             0         0           0      0   proc
              /isan                        614400    243076      371324     40   none
              /var/sysmgr                  512000     18896      493104      4   none
              /var/sysmgr/ftp              204800        40      204760      1   none
              /dev/shm                     358400     30268      328132      9   none
              /volatile                     20480         0       20480      0   none
              /debug                         2048         8        2040      1   none
              /dev/mqueue                       0         0           0      0   none
              /mnt/cfg/0                   326681      8360      301455      3   /dev/hda5
              /mnt/cfg/1                   326681      8359      301456      3   /dev/hda6
              /var/sysmgr/startup-cfg      409600      1168      408432      1   none
              /dev/pts                          0         0           0      0   devpts
              /mnt/pss                     326671      8625      301178      3   /dev/hda3
              /bootflash                  3122988    151756     2812592      6   /dev/hda4
              /bootflash_sup-remote       3122992    151760     2812592      6   127.1.1.1:/mnt/bootflash/
      
      

      What to Do Next

      Perform an in-service software upgrade (ISSU) to Release 5.2(1)SV3(1.1) or later.

      Verifying that the VSM has 3-GB of Hard Disk Drive Storage

      You can display the system internal flash to verify that you have a minimum of 3-GB of hard disk drive space.

      Procedure
        Step 1   Display the system internal flash.
        switch# show system internal flash
        Mount-on                  1K-blocks      Used   Available   Use%  Filesystem
        /                            307200     77808      229392     26   /dev/root
        /mnt/pss                     248895      8164      227879      4   /dev/sda3
        /proc                             0         0           0      0   proc
        /isan                        614400    372236      242164     61   none
        /var/sysmgr                 1048576    488704      559872     47   none
        /var/sysmgr/ftp              204800        52      204748      1   none
        /nxos/tmp                     20480         0       20480      0   none
        /dev/shm                     358400     89660      268740     26   none
        /volatile                     20480         0       20480      0   none
        /debug                         2048       128        1920      7   none
        /dev/mqueue                       0         0           0      0   none
        /mnt/cfg/0                   248895      4494      231551      2   /dev/sda5
        /mnt/cfg/1                   241116      4493      224175      2   /dev/sda6
        /var/sysmgr/startup-cfg      409600      5892      403708      2   none
        /dev/pts                          0         0           0      0   devpts
        /mnt/pss                     248895      8164      227879      4   /dev/sda3
        /bootflash                  2332296   1918624      295196     87   /dev/sda4
        /sys                              0         0           0      0   sysfs
        Step 2   Make sure that the number of blocks allocated to the /mnt/cfg/0, /mnt/cfg/1, /mnt/pss, and /bootflash partitions equals at least 3 GB.

        Guidelines and Limitations for Upgrading the Cisco Nexus 1000V

        Before attempting to migrate to any software image version, follow these guidelines:


        Caution


        During the upgrade process, the Cisco Nexus 1000V does not support any new additions such as modules, virtual NICs (vNICs), or VM NICs and does not support any configuration changes. VM NIC and vNIC port-profile changes might render VM NICs and vNICs in an unusable state.



        Note


        We recommended that you use vSphere 5.0 Update 1 or later instead of vSphere 5.0.


        • You are upgrading the Cisco Nexus 1000V software to the current release.

        • Scheduling—Schedule the upgrade when your network is stable and steady. Ensure that everyone who has access to the switch or the network is not configuring the switch or the network during this time. You cannot configure a switch during an upgrade.

        • Hardware—Avoid power interruptions to the hosts that run the VSM VMs during any installation procedure.

        • Connectivity to remote servers — do the following:

          • Copy the kickstart and system images from the remote server to the Cisco Nexus 1000V.

          • Ensure that the switch has a route to the remote server. The switch and the remote server must be in the same subnetwork if you do not have a router to route traffic between subnets.

        • Software images— Do the following:

          • Make sure that the system and kickstart images are the same version.

          • Retrieve the images in one of two ways:

            • Locally—Images are locally available on the upgrade CD-ROM/ISO image.

            • Remotely—Images are in a remote location and you specify the destination using the remote server parameters and the filename to be used locally.

        • Commands to use—Do the following:

          • Verify connectivity to the remote server by using the ping command.

          • If you are using Layer 3 mode for VSM-to-VEM connectivity, verify the IP address on the Layer 3 control interface using the show interface {control0 | mgmt0} command. If the IP address is missing, re-apply the IP address configuration on the corresponding Layer 3 control interface.

          • Use the install all command to upgrade your software. This command upgrades the VSMs.

          • Do not enter another install all command while running the installation. You can run commands other than configuration commands.

          • During the VSM upgrade, if you try to add a new VEM or any of the VEMs are detached due to uplink flaps, the VEM attachment is queued until the upgrade completes.

          • If VEMs get removed after the VSM upgrade, use the system switchover command to perform a system switchover after the HA pair is established.


        Note


        If the ESX hosts are not compatible with the software image that you install on the VSM, a traffic disruption occurs in those modules, depending on your configuration. The install all command output identifies these scenarios. The hosts must be at the right version before the upgrade.


        Before upgrading the VEMs, note these guidelines and limitations.


        Note


        It is your responsibility to monitor and install all the relevant patches on VMware ESX hosts.


        • The VEM software can be upgraded manually using the CLI or upgraded automatically using VUM.

        • During the VEM upgrade process, VEMs reattach to the VSM.

        • Connectivity to the VSM can be lost during a VEM upgrade when the interfaces of a VSM VM connect to its own Distributed Virtual Switch (DVS).

        • If you are upgrading a VEM using a Cisco Nexus 1000V bundle, follow the instructions in your VMware documentation. For more details about VMware bundled software, see the Cisco Nexus 1000V and VMware Compatibility Information document.


        Caution


        Do not enter the vemlog, vemcmd, or vempkt commands during the VEM upgrade process because these commands impact the upgrade.



        Note


        For ESXi 5.1 update 2 and later, the minimum versions are as follows:
        • VMware vCenter Server 5.1, 799731

        • VMware Update Manager 5.1, 782803

        For ESXi 5.5 update 1 and later, the minimum versions are as follows:
        • VMware vCenter Server 5.0.0, 455964

        • VMware Update Manager 5.0.0 432001

        If you plan to do a combined upgrade of ESX and VEM, the minimum vCenter Server/VUM version required is 623373/639867.

        This procedure is different from the upgrade to Release 4.2(1)SV1(4). In this procedure, you upgrade the VSMs first by using the install all command and then you upgrade the VEMs.


        • You can upgrade the hosts in the DVS a few at a time across multiple maintenance windows. The only exception is if you are upgrading the VEM alone using VUM with the ESX version unchanged.

        Upgrade Procedures

        The following table lists the upgrade steps.


        Note


        Ensure that you have changed the VSM mode to advanced, before upgrading VSM. VSG services are not available in the essential mode.
        Table 2 Upgrade Paths from Cisco Nexus 1000V Releases

        If you are running this configuration

        Follow these steps

        Release 4.0(4)SV1(1), 4.0(4)SV1(2), 4.2(1)SV1(4), 4.2(1)SV1(5.1), and 4.2(1)SV1(5.2)

        Direct upgrades from these releases are not supported.

        Releases 4.0(4)SV1(3x) Series

        1. Upgrading from Releases 4.0(4)SV1(3,3a,3b,3c,3d) to release 4.2(1)SV2(1.1) or later at the following URL: http:/​/​www.cisco.com/​c/​en/​us/​td/​docs/​switches/​datacenter/​nexus1000/​sw/​4_2_1_s_v_1_4_b/​upgrade/​software/​guide/​n1000v_​upgrade_​software.html#wp465259

        2. Upgrade from Releases 4.2(1)SV2(1.1) and later releases to the current release.

        Release 4.2(1)SV1(4x) Series with a vSphere release 4.0 Update 1 or later

        1. Upgrading from VMware Release 4.0 to VMwrae Release 5.0 or later.

        2. Upgrading VSMs from releases 4.2(1)SV1(4x) to 4.2(1)SV2(1.1) or later.

        3. Upgrading VEMs from releases 4.2(1)SV1(4x) to 4.2(1)SV2(1.1) or later.

        4. Upgrading VSMs from releases 4.2(1)SV2(1.1) or later to current release.

        5. Upgrading VEMs from releases 4.2(1)SV2(1.1) or later to current release.

        Release 4.2(1)SV1(4x) Series with a vSphere release 4.1 GA, patches, or updates

        1. Upgrading from VMware Release 4.1 to VMwrae Release 5.0 or later.

        2. Upgrading VSMs from releases 4.2(1)SV1(4x) to 4.2(1)SV2(1.1) or later.

        3. Upgrading VEMs from releases 4.2(1)SV1(4x) to 4.2(1)SV2(1.1) or later.

        4. Upgrading VSMs from releases 4.2(1)SV2(1.1) or later to current release.

        5. Upgrading VEMs from releases 4.2(1)SV2(1.1) or later to current release.

        Release 4.2(1)SV1(4x) with a vSphere release 5.0 GA, patches, or updates.

        1. Upgrading VSMs from releases 4.2(1)SV1(4x) to 4.2(1)SV2(1.1) or later.

        2. Upgrading VEMs from releases 4.2(1)SV1(4x) to 4.2(1)SV2(1.1) or later.

        3. Upgrading VSMs from releases 4.2(1)SV2(1.1) or later to current release.

        4. Upgrading VEMs from releases 4.2(1)SV2(1.1) or later to current release.

        The following table lists the upgrade steps when upgrading from Release 4.2(1)SV1(5x) and later releases to the current release.

        Table 3 Upgrade Paths from Releases 4.2(1)SV1(5x) and Later Releases

        If you are running this configuration

        Follow these steps

        With vSphere 4.1 GA, patches, or updates.

        1. Upgrading from VMware Release 4.1 to VMware Release 5.0 or later.

        2. Upgrading VSMs from releases 4.2(1)SV1(5.1x) to 4.2(1)SV2(1.1) or later.

        3. Upgrading VEMs from releases 4.2(1)SV1(5.1x) to 4.2(1)SV2(1.1) or later.

        4. Upgrading VSMs from releases 4.2(1)SV2(1.1) or later to current release.

        5. Upgrading VEMs from releases 4.2(1)SV2(1.1) or later to current release.

        With vSphere 5.0 GA, patches, or updates.

        1. Upgrading VSMs from releases 4.2(1)SV1(5.1x) to 4.2(1)SV2(1.1) or later.

        2. Upgrading VEMs from releases 4.2(1)SV1(5.1x) to 4.2(1)SV2(1.1) or later.

        3. Upgrading VSMs from releases 4.2(1)SV2(1.1) or later to current release.

        4. Upgrading VEMs from releases 4.2(1)SV2(1.1) or later to current release.

        With ESX version upgrade.

        Installing and Upgrading VMware

        Reserving the Memory and CPU on the Virtual Supervisor Module Virtual Machine

        From the current release of Cisco Nexus 1000V software, the VSM requires 4-GB RAM and two 2048-MHz vCPUs reservation to accommodate the new scalability limits.


        Note


        When you install the Cisco Nexus 1000V software VSM through the OVA files for the first time, the RAM and CPU reservations are automatically reflected.


        To upgrade to the current release of Cisco Nexus 1000V software and update the CPU and RAM reservations, use the following procedure:

        Procedure
          Step 1   Upgrade from the previous release of Cisco Nexus 1000V software to the current release of Cisco Nexus 1000V software.
          Step 2   Once the upgrade is complete, power off the secondary VSM.
          Step 3   Change the RAM size from 2 or 3 GB to 4 GB and change the RAM reservation from 2 or 3 GB to 4 GB.
          Step 4   Under CPU settings, change the number of vCPUs to 2 and change the CPU reservation from 1.5 GHz to 2048 MHz.
          Step 5   Power on the secondary VSM.
          Step 6   Perform a system switch over to get the secondary VSM as Active.
          Step 7   Power off the primary VSM and repeat steps 3 to 6.
          Step 8   After the primary and secondary VSM have the correct CPU and RAM reservations, the VSM is able to accommodate the scale numbers that are supported on Release 5.2(1)SV3(1.1) or later.
          Note   

          You do not have to change the CPU and RAM reservations to continue to support for the scale numbers supported in releases prior to Release 5.2(1)SV3(1.1).


          Reserving the Memory and CPU for the Virtual Supervisor Module in VSB on the Cloud Services Platform

          To change the memory reservations in the VSM VSB, use the following procedure:

          Before You Begin

          From the current release of Cisco Nexus 1000V software, the VSM requires 4-GB RAM and two vCPUs to accommodate the new scalability limits.

          Procedure
            Step 1   Login to the Cloud Services Platform command prompt.
            Step 2   Enter the VSM configuration mode.
            Step 3   Change the RAM size to 4 GB and change the vCPU number to 2.
            Note   

            With Cisco Nexus Cloud Services Platform Release 4.2(1)SP1(6.1) and later, the virtual service blades can remain powered on when you change the RAM size. In Cisco Nexus Cloud Services Platform releases earlier than 4.2(1)SP1(6.1), the primary/secondary virtual service blades must be powered off before you can change the RAM size.

            Step 4   Copy the running configuration to the startup configuration.
            Step 5   Reboot the secondary VSM VSB by using the shut and no shut commands.
            Step 6   Check if the secondary VSM has 4-GB RAM and two vCPUs.
            Step 7   Perform a system switch over from the primary VSM to make the secondary VSM as active with 4-GB RAM and two vCPUs.

            The primary VSM reboots and is in the standby state with 4-GB RAM and two vCPUs.


            Reserving the Memory and CPU for the Virtual Supervisor Module in VSB on the Cloud Services Platform Using the CLI

            To change the memory reservations in the VSM VSB using the CLI, use the following procedure:

            Before You Begin

            From the current release of Cisco Nexus 1000V software, VSM requires 4 GB RAM to accommodate the new scalability limits.

            Procedure
               Command or ActionPurpose
              Step 1 CSP configure terminal  

              Enters the global configuration mode.

               
              Step 2 CSP(config)# virtual-service-blade VSM for the current release  

              Enters the VSM configuration mode.

               
              Step 3 CSP(config-vsb-config)# ramsize 4096  

              Change the RAM size to 4 GB.

              Note   

              The virtual service blade is powered ON. Restart the VSB to reflect the change in RAM size. Perform a shutdown using the shutdown and no shutdown commands.

               
              Step 4CSP(config-vsb-config)# numcpu 2  

              Changing the number of CPUs to 2.

               
              Step 5 CSP(config-vsb-config)# copy running-config startup-config  

              Copies the running configuration to the startup configuration.

               
              Step 6 CSP(config-vsb-config)# shutdown secondary  

              Shuts down the secondary VSB.

               
              Step 7 CSP(config-vsb-config)# no shutdown secondary  

              Applies the RAM and vCPU changes.

               
              Step 8 VSM# system switchover  

              Performs a system switch over from primary VSM to make the secondary VSM as active with 4 GB RAM and two vCPUs.

               
              Step 9 VSM(standby)# show system resources
               

              Displays that the secondary VSM has 4 GB of RAM and two vCPUs.

               

              VSM Upgrade Procedures

              Software Images

              The software image install procedure is dependent on the following factors:

              • Software images—The kickstart and system image files reside in directories or folders that you can access from the Cisco Nexus 1000V software prompt.

              • Image version—Each image file has a version.

              • Disk—The bootflash: resides on the VSM.

              • ISO file—If a local ISO file is passed to the install all command, the kickstart and system images are extracted from the ISO file.

              In-Service Software Upgrades on Systems with Dual VSMs


              Note


              Performing an In-service Upgrade (ISSU) from Cisco Nexus 1000V Release 4.2(1)SV1(4x), 4.2(1)SV1(5.1x), 4.2(1)SV1(5.2x) to the current release of Cisco Nexus 1000V is not supported.


              The Cisco Nexus 1000V software supports in-service software upgrades (ISSUs) for systems with dual VSMs. An ISSU can update the software images on your switch without disrupting data traffic. Only control traffic is disrupted. If an ISSU causes a disruption of data traffic, the Cisco Nexus 1000V software warns you before proceeding so that you can stop the upgrade and reschedule it to a time that minimizes the impact on your network.


              Note


              On systems with dual VSMs, you should have access to the console of both VSMs to maintain connectivity when the switchover occurs during upgrades. If you are performing the upgrade over Secure Shell (SSH) or Telnet, the connection will drop when the system switchover occurs, and you must reestablish the connection.


              An ISSU updates the following images:

              • Kickstart image

              • System image

              • VEM images

              All of the following processes are initiated automatically by the upgrade process after the network administrator enters the install all command.

              ISSU Process for the Cisco Nexus 1000V

              The following figure shows the ISSU process.

              Figure 1. ISSU Process



              ISSU VSM Switchover

              The following figure provides an example of the VSM status before and after an ISSU switchover.

              Figure 2. Example of an ISSU VSM Switchover



              ISSU Command Attributes

              Support

              The install all command supports an in-service software upgrade (ISSU) on dual VSMs in an HA environment and performs the following actions:

              • Determines whether the upgrade is disruptive and asks if you want to continue.

              • Copies the kickstart and system images to the standby VSM. Alternatively, if a local ISO file is passed to the install all command instead, the kickstart and system images are extracted from the file.

              • Sets the kickstart and system boot variables.

              • Reloads the standby VSM with the new Cisco Nexus 1000V software.

              • Causes the active VSM to reload when the switchover occurs.

              Benefits

              The install all command provides the following benefits:

              • You can upgrade the VSM by using the install all command.

              • You can receive descriptive information on the intended changes to your system before you continue with the installation.

              • You have the option to cancel the command. Once the effects of the command are presented, you can continue or cancel when you see this question (the default is no):

                Do you want to continue (y/n) [n]: y
              • You can upgrade the VSM using the least disruptive procedure.

              • You can see the progress of this command on the console, Telnet, and SSH screens:

                • After a switchover process, you can see the progress from both the VSMs.

                • Before a switchover process, you can see the progress only from the active VSM.

              • The install all command automatically checks the image integrity, which includes the running kickstart and system images.

              • The install all command performs a platform validity check to verify that a wrong image is not used.

              • The Ctrl-C escape sequence gracefully ends the install all command. The command sequence completes the update step in progress and returns to the switch prompt. (Other upgrade steps cannot be ended by using Ctrl-C.)

              • After running the install all command, if any step in the sequence fails, the command completes the step in progress and ends.

              Upgrading VSMs from Releases 4.2(1)SV2(1.1) and Later Releases to Release 5.2(1)SV3(1.2) and Later Release

              Procedure
                Step 1   Log in to the active VSM.
                Step 2   Log in to Cisco.com to access the links provided in this document. To log in to Cisco.com, go to the URL http:/​/​www.cisco.com/​ and click Log In at the top of the page. Enter your Cisco username and password.
                Note    Unregistered Cisco.com users cannot access the links provided in this document.
                Step 3   Access the Software Download Center by using this URL:

                http:/​/​www.cisco.com/​public/​sw-center/​index.shtml

                Step 4   Navigate to the download site for your system.

                You see links to the download images for your switch.

                Step 5   Choose and download the Cisco Nexus 1000V zip file and extract the kickstart and system software files to a server.
                Step 6   Ensure that the required space is available for the image file(s) to be copied by entering the dir bootflash: command.
                Tip   

                We recommend that you have the kickstart and system image files for at least one previous release of the Cisco Nexus 1000V software on the system to use if the new image files do not load successfully.

                Step 7   Verify that there is space available on the standby VSM by entering the dir bootflash://sup-standby/ command .
                Step 8   Delete any unnecessary files to make space available if you need more space on the standby VSM.
                Step 9   If you plan to install the images from the bootflash:, copy the Cisco Nexus 1000V kickstart and system images or the ISO image to the active VSM by using a transfer protocol. You can use ftp:, tftp:, scp:, or sftp:. The examples in this procedure copies a kickstart and system image using scp:.
                Note    When you download an image file, change to your FTP environment IP address or DNS name and the path where the files are located.
                1. switch# copy scp://filepath/kickstart_filename bootflash:kickstart_filename

                  Copy the ISO image.

                2. switch# copy scp://filepath/system_filename bootflash:system_filename

                  Copy kickstart and system images.

                Step 10   switch# show install all impact kickstart bootflash:kickstart_filename system bootflash:system_filename

                Verify the ISSU upgrade for the kickstart and system images or the ISO image. The example in this procedure shows the kickstart and system images.

                Step 11   Read the release notes for the related image file. See the Cisco Nexus 1000V Release Notes.
                Step 12   Determine if the Cisco Virtual Security Gateway (Cisco VSG) is configured in the deployment by using the show vnm-pa status command .
                Note   

                If an output displaying a successful installation is displayed as in the example, the Cisco VSG is configured in the deployment. You must follow the upgrade procedure in the Cisco Virtual Security Gateway and Cisco Virtual Network Management Center Installation and Upgrade Guide. If an output displaying that the policy agent has not installed is displayed, continue to Step 13.

                Step 13   Save the running configuration to the startup configuration by using the copy running-config startup-config command.
                Step 14   Save the running configuration on the bootflash and externally.
                Note   

                You can also run a VSM backup. See the “Configuring VSM Backup and Recovery” chapter of the Cisco Nexus 1000V System Management Configuration Guide.

                1. Save the running configuration on the bootflash by using the copy running-config bootflash:run-cfg-backup command.
                2. Save the running configuration externally by using the copy running-config scp://external_backup_location command.
                Step 15   Perform the upgrade on the active VSM using the ISO or kickstart and system images by using the install all kickstart bootflash:kickstart_filename system bootflash:system_filename command. The example in this procedure shows the kickstart and system images.
                Step 16   Continue with the installation by pressing Y.

                If you press N, the installation exits gracefully.

                Note   

                As part of the upgrade process, the standby VSM is reloaded with new images. Once it becomes the HA standby again, the upgrade process initiates a switchover. The upgrade then continues from the new active VSM.

                Step 17   After the installation operation completes, log in and verify that the switch is running the required software version by using the switch# show version command
                Step 18   Copy the running configuration to the startup configuration to adjust the startup-config size by using the switch# copy running-config startup-config command
                Step 19   Display the log for the last installation by entering the following commands.
                1. switch# show install all status
                2. switch# attach module_name
                3. switch# show install all status
                Step 20   Review information about reserving memory and CPU on the VSM VM at the following URL: Reserving the Memory and CPU on the Virtual Supervisor Module Virtual Machine.
                Note   

                You must review this information, to accommodate the new scalability limits.


                VEM Upgrade Procedures

                Prerequisites for Upgrading VEMs


                Caution


                If VMware vCenter Server is hosted on the same ESX/ESXi host as a Cisco Nexus 1000V VEM, a VUM-assisted upgrade on the host fails. You should manually VMotion the vCenter Server VM to another host before you perform an upgrade.



                Note


                When you perform any VUM operation on hosts that are a part of a cluster, ensure that VMware HA, VMware fault tolerance (FT), and VMware Distributed Power Management (DPM) features are disabled for the entire cluster. Otherwise, VUM will fail to install the hosts in the cluster.


                • If you have VXLAN Gateway installed in your deployment, we recommend that you upgrade the VXLAN gateway service module after upgrading the VSM and before upgrading the VEM. This recommendation applies to upgrades to Release 5.2(1)SV3(1.1) and later only.

                • You are logged in to the VSM command-line interface (CLI) in EXEC mode.

                • You have a copy of your VMware documentation available for installing software on a host.

                • You have already obtained a copy of the VEM software file from one of the sources listed in VEM Software. For more information, see the Cisco Nexus 1000V and VMware Compatibility Information document.

                • If you need to migrate a vSphere host from ESX to ESXi, do it before the Cisco Nexus 1000V upgrade.

                • You have placed the VEM software file in /tmp on the vSphere host. Placing it in the root (/) directory might interfere with the upgrade. Make sure that the root RAM disk has at least 12 MB of free space by entering the vdf command.

                • On your upstream switches, you must have the following configuration.

                  • On Catalyst 6500 Series switches with the Cisco IOS software, enter the portfast trunk command or the portfast edge trunk command.

                  • On Cisco Nexus 5000 Series switches with the Cisco NX-OS software, enter the spanning-tree port type edge trunk command.

                • On your upstream switches, we highly recommend that you globally enable the following:

                  • Global BPDU Filtering

                  • Global BPDU Guard

                • On your upstream switches where you cannot globally enable BPDU Filtering and BPDU Guard, we highly recommend that you enter the following commands:

                  • spanning-tree bpdu filter

                  • spanning-tree bpdu guard

                • The collectors must be L3 reachable from at least one vmknic on each VEM host.

                • Strict Reverse Path Forwarding (RPF) may require disabling on the routers between the VEMs and the collectors.

                • For more information about configuring spanning tree, BPDU, or PortFast, see the documentation for your upstream switch.

                Upgrading Using a Customized ISO with a VMware ESX Image and a Cisco Nexus 1000V VEM Image

                Before You Begin
                • Install the VMware PowerCLI on a Windows platform. For more information, see the vSphere PowerCLI Installation Guide.

                • On the same Windows platform, where the VMware PowerCLI is installed, do one of the following:
                  • Download the ESX depot, which is a .zip file, to a local file path.

                  • Download the VEM offline bundle, which is a .zip file, to a local file path.

                Procedure
                  Step 1   Start the VMWare PowerCLI application.
                  Step 2   Connect to the vCenter Server by using the Connect-VIServer IP_address -User Administrator -Password password_name command.
                  Step 3   Load the ESX depot by using the Add-ESXSoftwareDepot path_name\file_name command.
                  Step 4   Display the image profiles by using the Get-EsxImageProfile command.
                  Step 5   Clone the ESX standard image profile by using the New-ESxImageProfile -CloneProfile ESXImageProfile_name -Name clone_profile command.
                  Note   

                  The image profiles are usually in READ-ONLY format. You must clone the image profile before adding the VEM image to it.

                  Step 6   Load the Cisco Nexus 1000V VEM offline bundle by using the Add-EsxSoftwareDepot VEM_offline_bundle command.
                  Step 7   Confirm that the n1kv-vib package is loaded by using the Get-EsxSoftwarePackage -Name package_name command.
                  Step 8   Bundle the n1kv-package into the cloned image profile by using the Add-EsxSoftwarePackage -ImageProfile n1kv-Image -SoftwarePackage cloned_image_profile command.
                  Step 9   Verify that the Cisco VIB is present by listing all the VIBs in the cloned image profile by entering the following commands.
                  1. $img = Get-EsxImageProfile n1kv-Image
                  2. $img.vibList

                  Verify that the Cisco VIB is present by listing all the VIBs in the cloned image profile.

                  Step 10   Export the image profile to an ISO file by using the Export-EsxImageProfile -ImageProfile n1kv-Image -FilePath iso_filepath command.

                  This example shows how to create an upgrade ISO with a VMware ESX image and a Cisco VEM image.

                  Note


                  The example may contain Cisco Nexus 1000V versions and filenames that are not relevant to your release. Refer to the Cisco Nexus 1000V and VMware Compatibility Information for your specific versions and filenames.


                  vSphere PowerCLI> Connect-VIServer 10.105.231.40 -User administrator -Password 'XXXXXXXX'
                  
                  Working with multiple default servers?
                  
                      Select [Y] if you want to work with more than one default servers. In this
                  case, every time when you connect to a different server using Connect-VIServer,
                   the new server connection is stored in an array variable together with the
                  previously connected servers. When you run a cmdlet and the target servers
                  cannot be determined from the specified parameters, the cmdlet runs against all
                   servers stored in the array variable.
                      Select [N] if you want to work with a single default server. In this case,
                  when you run a cmdlet and the target servers cannot be determined from the
                  specified parameters, the cmdlet runs against the last connected server.
                  
                      WARNING: WORKING WITH MULTIPLE DEFAULT SERVERS WILL BE ENABLED BY DEFAULT
                  IN A FUTURE RELEASE. You can explicitly set your own preference at any time by
                  using the DefaultServerMode parameter of Set-PowerCLIConfiguration.
                  
                  [Y] Yes  [N] No  [S] Suspend  [?] Help (default is "Y"): Y
                  
                  Name                           Port  User
                  ----                           ----  ----
                  10.105.231.40                  443   administrator
                  
                  vSphere PowerCLI> Add-EsxSoftwareDepot 'C:\Documents and Settings\Administrator\Desktop\upgrade\229\VEM510-201509199107-BG-release.zip'
                  
                  Depot Url
                  ---------
                  zip:C:\Documents and Settings\Administrator\Desktop\upgrade\229\VMware-ESXi-...
                  
                  vSphere PowerCLI> Get-EsxImageProfile
                  
                  Name                           Vendor          Last Modified   Acceptance Level
                  ----                           ------          -------------   ----------------
                  ESXi-5.1.0-201508198107s-no-... VMware, Inc.    08/12/2015 7:... PartnerSupported
                  CN1-CY                         CISCO           4/22/2013 11... PartnerSupported
                  ESXi-5.1.0-20121204001-stan... VMware, Inc.    12/7/2012 7:... PartnerSupported
                  ESXi-5.1.0-20121201001s-sta... VMware, Inc.    12/7/2012 7:... PartnerSupported
                  ESXi-5.1.0-799733-no-tools     VMware, Inc.    8/2/2012 3:0... PartnerSupported
                  ESXi-5.1.0-20121204001-no-t... VMware, Inc.    12/7/2012 7:... PartnerSupported
                  ESXi-5.1.0-799733-standard     VMware, Inc.    8/2/2012 3:0... PartnerSupported
                  
                  vSphere PowerCLI> New-EsxImageProfile -CloneProfile ESXi-5.1.0-799733-standard -Name FINAL
                  
                  cmdlet New-EsxImageProfile at command pipeline position 1
                  Supply values for the following parameters:
                  (Type !? for Help.)
                  Vendor: CISCO
                  
                  Name                           Vendor          Last Modified   Acceptance Level
                  ----                           ------          -------------   ----------------
                  FINAL                          CISCO           1/27/2015 3:0... PartnerSupported
                  
                  vSphere PowerCLI> Add-EsxSoftwareDepot 'C:\Documents and Settings\Administrator\Desktop\upgrade\229
                  \VEM510-201509199107-BG-release.zip'
                  
                  Depot Url
                  ---------
                  zip:C:\Documents and Settings\Administrator\Desktop\upgrade\229\cisco-vem-v1...
                  
                  vSphere PowerCLI> Get-EsxSoftwarePackage cisco*
                  
                  Name                     Version                        Vendor                Creation Date                                                                   e
                  ----                     -------                        ------                ------------
                  cisco-vem-v199-esx       5.2.1.3.1.5b.0-3.2.1  Cisco PartnerSupported          2015-08-14
                  
                  vSphere PowerCLI> Add-EsxSoftwarePackage -SoftwarePackage cisco-vem-v198-esx -ImageProfile FINAL
                  
                  Name                           Vendor          Last Modified   Acceptance Level
                  ----                           ------          -------------   ----------------
                  FINAL                          CISCO           08/14/2015 3:... PartnerSupported
                  
                  vSphere PowerCLI> $img = Get-EsxImageProfile FINAL
                  
                  vSphere PowerCLI> $img.vibList
                  
                  Name                     Version                        Vendor     Creation Dat
                                                                                     e
                  ----                     -------                        ------     ------------
                  scsi-bnx2i               1.9.1d.v50.1-5vmw.510.0.0.7... VMware     8/2/2012 ...
                  sata-sata-promise        2.12-3vmw.510.0.0.799733       VMware     8/2/2012 ...
                  net-forcedeth            0.61-2vmw.510.0.0.799733       VMware     8/2/2012 ...
                  esx-xserver              5.1.0-0.0.799733               VMware     8/2/2012 ...
                  misc-cnic-register       1.1-1vmw.510.0.0.799733        VMware     8/2/2012 ...
                  net-tg3                  3.110h.v50.4-4vmw.510.0.0.7... VMware     8/2/2012 ...
                  scsi-megaraid-sas        5.34-4vmw.510.0.0.799733       VMware     8/2/2012 ...
                  scsi-megaraid-mbox       2.20.5.1-6vmw.510.0.0.799733   VMware     8/2/2012 ...
                  scsi-ips                 7.12.05-4vmw.510.0.0.799733    VMware     8/2/2012 ...
                  net-e1000e               1.1.2-3vmw.510.0.0.799733      VMware     8/2/2012 ...
                  sata-ahci                3.0-13vmw.510.0.0.799733       VMware     8/2/2012 ...
                  sata-sata-svw            2.3-3vmw.510.0.0.799733        VMware     8/2/2012 ...
                  net-cnic                 1.10.2j.v50.7-3vmw.510.0.0.... VMware     8/2/2012 ...
                  net-e1000                8.0.3.1-2vmw.510.0.0.799733    VMware     8/2/2012 ...
                  ata-pata-serverworks     0.4.3-3vmw.510.0.0.799733      VMware     8/2/2012 ...
                  scsi-mptspi              4.23.01.00-6vmw.510.0.0.799733 VMware     8/2/2012 ...
                  ata-pata-hpt3x2n         0.3.4-3vmw.510.0.0.799733      VMware     8/2/2012 ...
                  net-s2io                 2.1.4.13427-3vmw.510.0.0.79... VMware     8/2/2012 ...
                  esx-base                 5.1.0-0.0.799733               VMware     8/2/2012 ...
                  net-vmxnet3              1.1.3.0-3vmw.510.0.0.799733    VMware     8/2/2012 ...
                  net-bnx2                 2.0.15g.v50.11-7vmw.510.0.0... VMware     8/2/2012 ...
                  cisco-vem-v171-esx       5.2.1.3.1.2.0-3.1.2            Cisco      2014-11-10
                  scsi-megaraid2           2.00.4-9vmw.510.0.0.799733     VMware     8/2/2012 ...
                  ata-pata-amd             0.3.10-3vmw.510.0.0.799733     VMware     8/2/2012 ...
                  ipmi-ipmi-si-drv         39.1-4vmw.510.0.0.799733       VMware     8/2/2012 ...
                  scsi-lpfc820             8.2.3.1-127vmw.510.0.0.799733  VMware     8/2/2012 ...
                  ata-pata-atiixp          0.4.6-4vmw.510.0.0.799733      VMware     8/2/2012 ...
                  esx-dvfilter-generic-... 5.1.0-0.0.799733               VMware     8/2/2012 ...
                  net-sky2                 1.20-2vmw.510.0.0.799733       VMware     8/2/2012 ...
                  scsi-qla2xxx             902.k1.1-9vmw.510.0.0.799733   VMware     8/2/2012 ...
                  net-r8169                6.011.00-2vmw.510.0.0.799733   VMware     8/2/2012 ...
                  sata-sata-sil            2.3-4vmw.510.0.0.799733        VMware     8/2/2012 ...
                  scsi-mpt2sas             10.00.00.00-5vmw.510.0.0.79... VMware     8/2/2012 ...
                  sata-ata-piix            2.12-6vmw.510.0.0.799733       VMware     8/2/2012 ...
                  scsi-hpsa                5.0.0-21vmw.510.0.0.799733     VMware     8/2/2012 ...
                  ata-pata-via             0.3.3-2vmw.510.0.0.799733      VMware     8/2/2012 ...
                  scsi-aacraid             1.1.5.1-9vmw.510.0.0.799733    VMware     8/2/2012 ...
                  scsi-rste                2.0.2.0088-1vmw.510.0.0.799733 VMware     8/2/2012 ...
                  ata-pata-cmd64x          0.2.5-3vmw.510.0.0.799733      VMware     8/2/2012 ...
                  ima-qla4xxx              2.01.31-1vmw.510.0.0.799733    VMware     8/2/2012 ...
                  net-igb                  2.1.11.1-3vmw.510.0.0.799733   VMware     8/2/2012 ...
                  scsi-qla4xxx             5.01.03.2-4vmw.510.0.0.799733  VMware     8/2/2012 ...
                  block-cciss              3.6.14-10vmw.510.0.0.799733    VMware     8/2/2012 ...
                  scsi-aic79xx             3.1-5vmw.510.0.0.799733        VMware     8/2/2012 ...
                  tools-light              5.1.0-0.0.799733               VMware     8/2/2012 ...
                  uhci-usb-uhci            1.0-3vmw.510.0.0.799733        VMware     8/2/2012 ...
                  sata-sata-nv             3.5-4vmw.510.0.0.799733        VMware     8/2/2012 ...
                  sata-sata-sil24          1.1-1vmw.510.0.0.799733        VMware     8/2/2012 ...
                  net-ixgbe                3.7.13.6iov-10vmw.510.0.0.7... VMware     8/2/2012 ...
                  ipmi-ipmi-msghandler     39.1-4vmw.510.0.0.799733       VMware     8/2/2012 ...
                  scsi-adp94xx             1.0.8.12-6vmw.510.0.0.799733   VMware     8/2/2012 ...
                  scsi-fnic                1.5.0.3-1vmw.510.0.0.799733    VMware     8/2/2012 ...
                  ata-pata-pdc2027x        1.0-3vmw.510.0.0.799733        VMware     8/2/2012 ...
                  misc-drivers             5.1.0-0.0.799733               VMware     8/2/2012 ...
                  net-enic                 1.4.2.15a-1vmw.510.0.0.799733  VMware     8/2/2012 ...
                  net-be2net               4.1.255.11-1vmw.510.0.0.799733 VMware     8/2/2012 ...
                  net-nx-nic               4.0.558-3vmw.510.0.0.799733    VMware     8/2/2012 ...
                  esx-xlibs                5.1.0-0.0.799733               VMware     8/2/2012 ...
                  net-bnx2x                1.61.15.v50.3-1vmw.510.0.0.... VMware     8/2/2012 ...
                  ehci-ehci-hcd            1.0-3vmw.510.0.0.799733        VMware     8/2/2012 ...
                  ohci-usb-ohci            1.0-3vmw.510.0.0.799733        VMware     8/2/2012 ...
                  net-r8168                8.013.00-3vmw.510.0.0.799733   VMware     8/2/2012 ...
                  esx-tboot                5.1.0-0.0.799733               VMware     8/2/2012 ...
                  ata-pata-sil680          0.4.8-3vmw.510.0.0.799733      VMware     8/2/2012 ...
                  ipmi-ipmi-devintf        39.1-4vmw.510.0.0.799733       VMware     8/2/2012 ...
                  scsi-mptsas              4.23.01.00-6vmw.510.0.0.799733 VMware     8/2/2012 ...
                  
                  vSphere PowerCLI> Export-EsxImageProfile -ImageProfile FINAL -FilePath 'C:\Documents and Settings\Administrator\Desktop\FINAL.iso' -ExportToIso
                  
                  

                  Upgrading the vCenter Server


                  Note


                  This upgrade procedure applies to vCenter Server 5.0, 5.0 Update 1 and later, 5.1, and 5.5 versions.


                  Before You Begin
                  • Download the upgrade ISO file that contains your desired ESXi image and the desired Cisco Nexus 1000V image.

                  • See the Cisco Nexus 1000V and VMware Compatibility Information document to determine the correct VIB Version, VEM Bundle, Host Build, vCenter Server, and Update Manager versions.

                  Procedure
                    Step 1   Navigate to the VMware vSphere installation file.
                    Note   

                    If you have the ISO image, you should mount it on the host.

                    Step 2   Double-click autorun.
                    Step 3   In the VMware vCenter Installer screen, click vCenter Server.
                    Step 4   Click Install.
                    Step 5   Choose a language and click OK.
                    Step 6   Click Next.
                    Step 7   In the Patent Agreement screen, click Next.
                    Step 8   In the License Agreement screen, click the I agree to the terms in the license agreement radio button.
                    Step 9   Click Next.
                    Step 10   In the Database Options screen, click Next.
                    Step 11   Click the Upgrade existing vCenter Server database radio button and check the I have taken a backup of the existing vCenter Server database and SSL certificates in the folder: C:\ProgramData\VMware\VMware VirtualCenter\SSL\. check box.
                    Step 12   From the Windows Start Menu, click Run.
                    Step 13   Enter the name of the folder that contains the vCenter Server database and click OK.
                    Step 14   Drag a copy of the parent folder (SSL) to the desktop as a backup.
                    Step 15   Return to the installer program.
                    Step 16   Click Next.
                    Step 17   In the vCenter Agent Upgrade screen, click the Automatic radio button.
                    Step 18   Click Next.
                    Step 19   In the vCenter Server Service screen, check the Use SYSTEM Account check box.
                    Step 20   Click Next.
                    Step 21   Review the port settings and click Next.
                    Step 22   In the vCenter Server JVM Memory screen based on the number of hosts, click the appropriate memory radio button.
                    Step 23   Click Next.
                    Step 24   Click Install.
                    Step 25   Click Finish.

                    This step completes the upgrade of the vCenter Server.

                    Step 26   Upgrade the VMware vSphere Client to your desired ESXi version.
                    Step 27   Open the VMware vSphere Client.
                    Step 28   From the Help menu, choose About VMware vSphere.
                    Step 29   Confirm that the vSphere Client and the VMware vCenter Server are both the same VMware versions.
                    Step 30   Click OK, and exit the VMware vSphere Client.

                    What to Do Next

                    Complete the steps in Upgrading the vCenter Update Manager to Release 5.5.

                    Upgrading VEMs Using VUM

                    The steps to upgrade VEMS using VUM are as follows:

                    Procedure
                      Step 1   Upgrade the VEM from the VSM. See Upgrading the VEMs Using VMware Update Manager from Release 4.2(1)SV2(1.1x) and Later Releases to the Current Release.
                      Step 2   Upgrade the VEM software. See Upgrading the VEM Software Using the vCLI.
                      Step 3   Upgrade both ESX and Cisco Nexus 1000V. See Combined Upgrade of VMware vSphere and Cisco Nexus 1000V.

                      Upgrading the VEMs Using VMware Update Manager from Release 4.2(1)SV2(1.1x) and Later Releases to the Current Release


                      Caution


                      If removable media is still connected (for example, if you have installed the VSM using ISO and forgot to remove the media), host movement to maintenance mode fails and the VUM upgrade fails.


                      Before You Begin

                      When using VUM, the feature http-server enable command must be enabled.

                      Procedure
                        Step 1   switch# show vmware vem upgrade status

                        Display the current configuration.

                        Step 2   switch# vmware vem upgrade notify

                        Coordinate with and notify the server administrator of the VEM upgrade process.

                        Step 3   switch# show vmware vem upgrade status

                        Verify that the upgrade notification was sent.

                        Note   

                        Verify that the Upgrade Status contains the highlighted text. If the text is not present, check the Upgrade Error line and consult the Cisco Nexus 1000V Troubleshooting Guide.

                        Step 4   switch# show vmware vem upgrade status

                        Verify that the server administrator has accepted the upgrade in the vCenter. For more information about how the server administrator accepts the VEM upgrade, see Accepting the VEM Upgrade. Coordinate the notification acceptance with the server administrator. After the server administrator accepts the upgrade, proceed with the VEM upgrade.

                        Note   

                        Verify that the Upgrade Status contains the highlighted text. If the text is not present, check the Upgrade Error line and consult the Cisco Nexus 1000V Troubleshooting Guide.

                        Step 5   Initiate the VUM upgrade process with the following commands.
                        Note   

                        Before entering the following commands, communicate with the server administrator to confirm that the VUM process is operational.

                        The vCenter Server locks the DVS and triggers VUM to upgrade the VEMs.

                        1. switch# vmware vem upgrade proceed
                        2. switch# show vmware vem upgrade status
                        Note   

                        The DVS bundle ID is updated and is highlighted.

                        If the host is using ESXi 5.0.0 or a later release and your DRS settings are enabled to allow it, VUM automatically VMotions the VMs from the host to another host in the cluster and places the ESXi in maintenance mode to upgrade the VEM. This process is continued for other hosts in the DRS cluster until all the hosts are upgraded in the cluster. For details about DRS settings required and vMotion of VMs, visit the VMware documentation related to Creating a DRS Cluster.

                        Step 6   switch# show vmware vem upgrade status

                        Check for the upgrade complete status.

                        Step 7   Clear the VEM upgrade status after the upgrade process is complete with the following commands.
                        1. switch# vmware vem upgrade complete
                        2. switch# show vmware vem upgrade status
                        Step 8   switch# show module

                        Verify that the upgrade process is complete.

                        The upgrade is complete.


                        The following example shows how to upgrade VEMs using VUM.

                        Note


                        The example may contain Cisco Nexus 1000V versions and filenames that are not relevant to your release. Refer to the Cisco Nexus 1000V and VMware Compatibility Information for your specific versions and filenames.


                        switch# show vmware vem upgrade status 
                        
                        Upgrade VIBs: System VEM Image
                        Upgrade Status:
                        Upgrade Notification Sent Time:
                        Upgrade Status Time(vCenter):
                        Upgrade Start Time:
                        Upgrade End Time(vCenter):
                        Upgrade Error:
                        Upgrade Bundle ID:
                            VSM: VEM500-201509199101-BG
                            DVS: VEM500-201401164100-BG
                        switch# 
                        switch# vmware vem upgrade notify 
                        Warning: 
                        Please ensure the hosts are running compatible ESX versions for the upgrade. Refer to corresponding
                        "Cisco Nexus 1000V and VMware Compatibility Information" guide.
                        switch# show vmware vem upgrade status 
                        switch# show vmware vem upgrade status
                        
                        Upgrade VIBs: System VEM Image
                        Upgrade Status: Upgrade Availability Notified in vCenter
                        Upgrade Notification Sent Time: Mon Sep 21 06:43:57 2015
                        Upgrade Status Time(vCenter):
                        Upgrade Start Time:
                        Upgrade End Time(vCenter):
                        Upgrade Error:
                        Upgrade Bundle ID:
                            VSM: VEM500-201509199101-BG
                            DVS: VEM500-201401164100-BG
                        
                        switch# show vmware vem upgrade status 
                        
                        switch# show vmware vem upgrade status
                        Upgrade VIBs: System VEM Image
                        Upgrade Status: Upgrade Accepted by vCenter Admin
                        Upgrade Notification Sent Time: Mon Sep 21 06:43:57 2015
                        Upgrade Status Time(vCenter): Mon Sep 21 09:13:29 2015
                        Upgrade Start Time:
                        Upgrade End Time(vCenter):
                        Upgrade Error:
                        Upgrade Bundle ID:
                            VSM: VEM500-201509199101-BG
                            DVS: VEM500-201401164100-BG
                        
                        switch#
                        switch# vmware vem upgrade proceed 
                        switch# show vmware vem upgrade status 
                        
                        switch# show vmware vem upgrade status
                        
                        Upgrade VIBs: System VEM Image
                        Upgrade Status: Upgrade In Progress in vCenter
                        Upgrade Notification Sent Time: Mon Sep 21 06:43:57 2015
                        Upgrade Status Time(vCenter): Mon Sep 21 09:13:29 2015
                        Upgrade Start Time: Mon Sep 21 06:45:15 2015
                        Upgrade End Time(vCenter):
                        Upgrade Error:
                        Upgrade Bundle ID:
                            VSM: VEM500-201509199101-BG
                            DVS: VEM500-201509199101-BG
                        
                        switch#
                        switch# show vmware vem upgrade status 
                        
                        switch# show vmware vem upgrade status
                        
                        Upgrade VIBs: System VEM Image
                        Upgrade Status: Upgrade Complete in vCenter
                        Upgrade Notification Sent Time: Mon Sep 21 06:57:04 2015
                        Upgrade Status Time(vCenter): Mon Sep 21 09:13:29 2015
                        Upgrade Start Time: Mon Sep 21 07:38:41 2015
                        Upgrade End Time(vCenter): Mon Sep 21 10:09:34 2015
                        Upgrade Error:
                        Upgrade Bundle ID:
                            VSM: VEM500-201509199101-BG
                            DVS: VEM500-201509199101-BG
                        
                        switch#
                        switch# vmware vem upgrade complete 
                        switch# show vmware vem upgrade status 
                        
                        switch# show vmware vem upgrade status
                        
                        Upgrade VIBs: System VEM Image
                        Upgrade Status:
                        Upgrade Notification Sent Time:
                        Upgrade Status Time(vCenter):
                        Upgrade Start Time:
                        Upgrade End Time(vCenter):
                        Upgrade Error:
                        Upgrade Bundle ID:
                            VSM: VEM500-201509199101-BG
                            DVS: VEM500-201509199101-BG
                        
                        switch#
                        switch(config)# show module 
                        Mod  Ports  Module-Type                       Model               Status
                        ---  -----  --------------------------------  ------------------  ------------
                        1    0      Virtual Supervisor Module         Nexus1000V          ha-standby
                        2    0      Virtual Supervisor Module         Nexus1000V          active *
                        4    1022   Virtual Ethernet Module           NA                  ok
                        5    1022   Virtual Ethernet Module           NA                  ok
                        12   1022   Virtual Ethernet Module           NA                  ok
                        15   1022   Virtual Ethernet Module           NA                  ok
                        
                        
                        Mod  Sw                  Hw
                        ---  ------------------  ------------------------------------------------
                        1    5.2(1)SV3(1.5b)     0.0
                        2    5.2(1)SV3(1.5b)     0.0
                        4    5.2(1)SV3(1.5b)     VMware ESXi 6.0.0 Releasebuild-2494585 (6.0)
                        5    5.2(1)SV3(1.5b)     VMware ESXi 5.5.0 Releasebuild-2068190 (3.2)
                        12   5.2(1)SV3(1.5b)     VMware ESXi 5.5.0 Releasebuild-2068190 (3.2)
                        15   5.2(1)SV3(1.5b)     VMware ESXi 5.1.0 Releasebuild-2323236 (3.1)
                        
                        
                        Mod  Server-IP        Server-UUID                           Server-Name
                        ---  ---------------  ------------------------------------  --------------------
                        1    10.197.133.108   NA                                    NA
                        2    10.197.133.108   NA                                    NA
                        4    10.197.132.43    e6c1a563-bc9e-11e0-bd1d-30e4dbc2baba  NA
                        5    10.197.132.42    e0829a21-bc61-11e0-bd1d-30e4dbc2ba66  10.197.132.42
                        12   10.197.132.46    db8b80ac-af1d-11e0-a4e7-30e4dbc26b82  10.197.132.46
                        15   10.197.132.44    7b1a5e63-bcd0-11e0-bd1d-30e4dbc2c3ae  10.197.132.44
                        
                        * this terminal session
                        
                        switch(config)# 

                        Note


                        The lines with the bold characters in the preceding example display that all VEMs are upgraded to the current release.


                        Accepting the VEM Upgrade

                        Before You Begin
                        • The network and server administrators must coordinate the upgrade procedure with each other.

                        • You have received a notification in the vCenter Server that a VEM software upgrade is available.

                        Procedure
                          Step 1   In the vCenter Server, choose Inventory > Networking.
                          Step 2   Click the vSphere Client DVS Summary tab to check for the availability of a software upgrade.
                          Figure 3. vSphere Client DVS Summary Tab



                          Step 3   Click Apply upgrade.

                          The network administrator is notified that you are ready to apply the upgrade to the VEMs.


                          Upgrading the VEM Software Using the vCLI

                          You can upgrade the VEM software by using the vCLI.

                          Before You Begin
                          • If you are using vCLI, do the following:

                            • You have downloaded and installed the VMware vCLI. For information about installing the vCLI, see the VMware vCLI documentation.

                            • You are logged in to the remote host where the vCLI is installed.


                              Note


                              The vSphere command-line interface (vCLI) command set allows you to enter common system administration commands against ESXi systems from any machine with network access to those systems. You can also enter most vCLI commands against a vCenter Server system and target any ESXi system that the vCenter Server system manages. vCLI commands are especially useful for ESXi hosts because ESXi does not include a service console.


                          • Check Cisco Nexus 1000V and VMware Compatibility Information for compatible versions.

                          • You have already copied the VEM software installation file to the /tmp directory. Do not copy the files to the root (/) folder.

                          • You know the name of the VEM software file to be installed.

                          Procedure
                            Step 1   [root@serialport -]# cd tmp

                            Go to the directory where the new VEM software was copied.

                            Step 2   Determine the upgrade method that you want to use and enter the appropriate command.
                            • vihostupdate

                              Installs the ESXi and VEM software simultaneously if you are using the vCLI.

                            Step 3   For ESXi 5.0.0 or later hosts, enter the appropriate commands as they apply to you.
                            1. ~ # esxcli software vib install -d /absolute-path/VEM_bundle
                            2. ~ # esxcli software vib install -v /absolute-path/vib_file
                            Note   

                            You must specify the absolute path to the VEM_bundle and vib_file files. The absolute path is the path that starts at the root of the file system such as /tmp/vib_file.

                            Step 4   Display values with which to compare to Cisco Nexus 1000V and VMware Compatibility Information by typing the following commands.
                            1. [root@serialport tmp]# vmware -v
                            2. root@serialport tmp]# # esxupdate query
                            3. [root@host212 ~]# . ~ # vem status -v
                            4. [root@host212 ~]# vemcmd show version
                            Step 5   switch# show module

                            Display that the VEMs were upgraded by entering the command on the VSM.


                            If the upgrade was successful, the installation procedure is complete.

                            The following example shows how to upgrade the VEM software using the vCLI.

                            Note


                            The example may contain Cisco Nexus 1000V versions and filenames that are not relevant to your release. Refer to the Cisco Nexus 1000V and VMware Compatibility Information for your specific versions and filenames.


                            [root@serialport -]# cd tmp
                            [root@serialport tmp]# 
                            esxupdate -b [VMware offline update bundle] update
                            ~ # esxcli software vib install -d /tmp/VEM510-201509199107-BGrelease.zip
                            Installation Result
                               Message: Operation finished successfully.
                               Reboot Required: false
                               VIBs Installed: Cisco_bootbank_cisco-vem-v199-5.2.1.3.1.5b.0-3.0.1.VIB
                               VIBs Removed: 
                               VIBs Skipped: 
                            ~ #
                            
                            ~ # esxcli software vib install -v /tmp/cross_cisco-vem-vVEM510-201509199107-BG.vib
                            Installation Result
                               Message: Operation finished successfully.
                               Reboot Required: false
                               VIBs Installed: Cisco_bootbank_cisco-vem-v199-5.2.1.3.1.5b.0-3.0.1.VIB
                               VIBs Removed: 
                               VIBs Skipped: 
                            ~ #
                            [root@serialport tmp]# vmware -v -l
                            VMware ESXi 5.5.0 build-2068190
                            VMware ESXi 5.5.0 Update 2
                            ~ #
                            
                            root@serialport tmp]# # esxupdate query
                            ------Bulletin ID------- -----Installed----- --------------Summary---------------
                            VEM510-201509199107-BG1 2015-09-20T08:18:22 Cisco Nexus 1000V 5.2(1)SV3(1.5b)
                            
                            
                            ~ # vem status -v
                            ~ # vem status -v
                            Package vssnet-esxesx2013-release
                            Version 5.2.1.3.1.5b.0-3.2.1
                            Build 1
                            Date Sun Sep 20 08:58:05 PDT 2015
                            
                            VEM modules are loaded
                            
                            Switch Name      Num Ports   Used Ports  Configured Ports  MTU     Uplinks
                            vSwitch0         2432        82          128               1500    vmnic0
                            DVS Name         Num Ports   Used Ports  Configured Ports  MTU     Uplinks
                            cyp              1024        50          1024              1500    vmnic7,vmnic5,vmnic4
                            
                            VEM Agent (vemdpa) is running
                            
                            ~ # vemcmd show version
                            VEM Version: 5.2.1.3.1.5b.0-3.2.1
                            VSM Version: 5.2(1)SV3(1.5b)
                            System Version: VMware ESXi 5.5.0 Releasebuild-2068190
                            ESX Version Update Level: 2
                            ~ #
                            switch# show module 
                            Mod  Ports  Module-Type                       Model               Status
                            ---  -----  --------------------------------  ------------------  ------------
                            1    0      Virtual Supervisor Module         Nexus1000V          ha-standby
                            2    0      Virtual Supervisor Module         Nexus1000V          active *
                            4    1022   Virtual Ethernet Module           NA                  ok
                            5    1022   Virtual Ethernet Module           NA                  ok
                            12   1022   Virtual Ethernet Module           NA                  ok
                            15   1022   Virtual Ethernet Module           NA                  ok
                            
                            
                            Mod  Sw                  Hw
                            ---  ------------------  ------------------------------------------------
                            1    5.2(1)SV3(1.5b)     0.0
                            2    5.2(1)SV3(1.5b)     0.0
                            4    5.2(1)SV3(1.5b)     VMware ESXi 6.0.0 Releasebuild-2494585 (6.0)
                            5    5.2(1)SV3(1.5b)     VMware ESXi 5.5.0 Releasebuild-2068190 (3.2)
                            12   5.2(1)SV3(1.5b)     VMware ESXi 5.5.0 Releasebuild-2068190 (3.2)
                            15   5.2(1)SV3(1.5b)     VMware ESXi 5.1.0 Releasebuild-2323236 (3.1)
                            
                            
                            Mod  Server-IP        Server-UUID                           Server-Name
                            ---  ---------------  ------------------------------------  --------------------
                            1    10.197.133.108   NA                                    NA
                            2    10.197.133.108   NA                                    NA
                            4    10.197.132.43    e6c1a563-bc9e-11e0-bd1d-30e4dbc2baba  NA
                            5    10.197.132.42    e0829a21-bc61-11e0-bd1d-30e4dbc2ba66  10.197.132.42
                            12   10.197.132.46    db8b80ac-af1d-11e0-a4e7-30e4dbc26b82  10.197.132.46
                            15   10.197.132.44    7b1a5e63-bcd0-11e0-bd1d-30e4dbc2c3ae  10.197.132.44
                            
                            * this terminal session
                            
                            switch#

                            Note


                            The highlighted text in the previous command output confirms that the upgrade was successful.


                            Upgrading the VEMs Manually from Release 4.2(1)SV2(1.1x) and Later Releases to the Current Release

                            Before You Begin

                            Note


                            If VUM is installed, it should be disabled.


                            To manually install or upgrade the Cisco Nexus 1000V VEM on an ESXi host, follow the steps in Upgrading the VEM Software Using the vCLI.

                            To upgrade the VEMs manually, perform the following steps as network administrator:


                            Note


                            This procedure is performed by the network administrator. Before proceeding with the upgrade, make sure that the VMs are powered off if you are not running the required patch level.



                            Caution


                            If removable media is still connected, (for example, if you have installed the VSM using ISO and forgot to remove the media), host movement to maintenance mode fails and the VEM upgrade fails.


                            Procedure
                              Step 1   switch# vmware vem upgrade notify

                              Coordinate with and notify the server administrator of the VEM upgrade process.

                              Step 2   switch# show vmware vem upgrade status

                              Verify that the upgrade notification was sent.

                              Step 3   switch# show vmware vem upgrade status

                              Verify that the server administrator has accepted the upgrade in vCenter Server. For details about the server administrator accepting the VEM upgrade, see Accepting the VEM Upgrade. After the server administrator accepts the upgrade, proceed with the VEM upgrade.

                              Step 4   Perform one of the following tasks:
                              • If the ESXi host is not hosting the VSM, proceed to Step 5.

                              • If the ESXi host is hosting the VSM, coordinate with the server administrator to migrate the VSM to a host that is not being upgraded. Proceed to Step 5.

                              Step 5   switch# vmware vem upgrade proceed

                              Initiate the Cisco Nexus 1000V Bundle ID upgrade process.

                              Note   

                              If VUM is enabled in the vCenter environment, disable it before entering the vmware vem upgrade proceed command to prevent the new VIBs from being pushed to all the hosts.

                              Enter the vmware vem upgrade proceed command so that the Cisco Nexus 1000V Bundle ID on the vCenter Server gets updated. If VUM is enabled and you do not update the Bundle ID, an incorrect VIB version is pushed to the VEM when you next add the ESXi to the VSM.

                              Note   

                              If VUM is not installed, the “The object or item referred to could not be found” error appears in the vCenter Server task bar. You can ignore this error message.

                              Step 6   switch# show vmware vem upgrade status

                              Check for the upgrade complete status.

                              Step 7   Coordinate with and wait until the server administrator upgrades all ESXi host VEMs with the new VEM software release and informs you that the upgrade process is complete.

                              The server administrator performs the manual upgrade by using the vihostupdate command or the esxcli command. For more information, see Upgrading the VEM Software Using the vCLI.

                              Step 8   switch# vmware vem upgrade complete

                              Clear the VEM upgrade status after the upgrade process is complete.

                              Step 9   switch# show vmware vem upgrade status

                              Check the upgrade status once again.

                              Step 10   switch# show module
                              Verify that the upgrade process is complete.
                              Note   

                              The line with the bold characters in the preceding example display that all VEMs are upgraded to the current release.

                              The upgrade is complete.


                              The following example shows how to upgrade VEMs manually.

                              Note


                              The example may contain Cisco Nexus 1000V versions and filenames that are not relevant to your release. Refer to the Cisco Nexus 1000V and VMware Compatibility Information for your specific versions and filenames.


                              switch# show vmware vem upgrade status 
                              
                              switch# show vmware vem upgrade status
                              
                              Upgrade VIBs: System VEM Image
                              Upgrade Status:
                              Upgrade Notification Sent Time:
                              Upgrade Status Time(vCenter):
                              Upgrade Start Time:
                              Upgrade End Time(vCenter):
                              Upgrade Error:
                              Upgrade Bundle ID:
                                  VSM: VEM500-201509199101-BG
                                  DVS: VEM500-201401164100-BG
                              switch# 
                              switch# vmware vem upgrade notify 
                              Warning: 
                              Please ensure the hosts are running compatible ESX versions for the upgrade. Refer to corresponding
                              "Cisco Nexus 1000V and VMware Compatibility Information" guide.
                              
                              switch# show vmware vem upgrade status 
                              
                              switch# show vmware vem upgrade status
                              
                              Upgrade VIBs: System VEM Image
                              Upgrade Status: Upgrade Availability Notified in vCenter
                              Upgrade Notification Sent Time: Mon Sep 21 06:43:57 2015
                              Upgrade Status Time(vCenter):
                              Upgrade Start Time:
                              Upgrade End Time(vCenter):
                              Upgrade Error:
                              Upgrade Bundle ID:
                                  VSM: VEM500-201509199101-BG
                                  DVS: VEM500-201401164100-BG
                              
                              switch# show vmware vem upgrade status
                              Upgrade VIBs: System VEM Image
                              Upgrade Status: Upgrade Accepted by vCenter Admin
                              Upgrade Notification Sent Time: Mon Sep 21 06:43:57 2015
                              Upgrade Status Time(vCenter): Mon Sep 21 09:13:29 2015
                              Upgrade Start Time:
                              Upgrade End Time(vCenter):
                              Upgrade Error:
                              Upgrade Bundle ID:
                                  VSM: VEM500-201509199101-BG
                                  DVS: VEM500-201401164100-BG
                              
                              switch# 
                              switch# vmware vem upgrade proceed
                              switch# show vmware vem upgrade status 
                              
                              switch# show vmware vem upgrade status
                              
                              Upgrade VIBs: System VEM Image
                              Upgrade Status: Upgrade In Progress in vCenter
                              Upgrade Notification Sent Time: Mon Sep 21 06:43:57 2015
                              Upgrade Status Time(vCenter): Mon Sep 21 09:13:29 2015
                              Upgrade Start Time: Mon Sep 21 06:45:15 2015
                              Upgrade End Time(vCenter):
                              Upgrade Error:
                              Upgrade Bundle ID:
                                  VSM: VEM500-201509199101-BG
                                  DVS: VEM500-201509199101-BG
                              
                              
                              
                              switch# show vmware vem upgrade status 
                              
                              switch# show vmware vem upgrade status
                              
                              Upgrade VIBs: System VEM Image
                              Upgrade Status: Upgrade Complete in vCenter
                              Upgrade Notification Sent Time: Mon Sep 21 06:57:04 2015
                              Upgrade Status Time(vCenter): Mon Sep 21 09:13:29 2015
                              Upgrade Start Time: Mon Sep 21 07:38:41 2015
                              Upgrade End Time(vCenter): Mon Sep 21 10:09:34 2015
                              Upgrade Error:
                              Upgrade Bundle ID:
                                  VSM: VEM500-201509199101-BG
                                  DVS: VEM500-201509199101-BG
                              
                              switch#
                              switch# vmware vem upgrade complete 
                              switch# show vmware vem upgrade status 
                              
                              switch# show vmware vem upgrade status
                              
                              Upgrade VIBs: System VEM Image
                              Upgrade Status:
                              Upgrade Notification Sent Time:
                              Upgrade Status Time(vCenter):
                              Upgrade Start Time:
                              Upgrade End Time(vCenter):
                              Upgrade Error:
                              Upgrade Bundle ID:
                                  VSM: VEM500-201509199101-BG
                                  DVS: VEM500-201509199101-BG
                              
                              
                              
                              switch(config)# show module 
                              cyp# sh module
                              Mod  Ports  Module-Type                       Model               Status
                              ---  -----  --------------------------------  ------------------  ------------
                              1    0      Virtual Supervisor Module         Nexus1000V          ha-standby
                              2    0      Virtual Supervisor Module         Nexus1000V          active *
                              4    1022   Virtual Ethernet Module           NA                  ok
                              5    1022   Virtual Ethernet Module           NA                  ok
                              12   1022   Virtual Ethernet Module           NA                  ok
                              15   1022   Virtual Ethernet Module           NA                  ok
                              
                              
                              Mod  Sw                  Hw
                              ---  ------------------  ------------------------------------------------
                              1    5.2(1)SV3(1.5b)     0.0
                              2    5.2(1)SV3(1.5b)     0.0
                              4    5.2(1)SV3(1.5b)     VMware ESXi 6.0.0 Releasebuild-2494585 (6.0)
                              5    5.2(1)SV3(1.5b)     VMware ESXi 5.5.0 Releasebuild-2068190 (3.2)
                              12   5.2(1)SV3(1.5b)     VMware ESXi 5.5.0 Releasebuild-2068190 (3.2)
                              15   5.2(1)SV3(1.5b)     VMware ESXi 5.1.0 Releasebuild-2323236 (3.1)
                              
                              
                              Mod  Server-IP        Server-UUID                           Server-Name
                              ---  ---------------  ------------------------------------  --------------------
                              1    10.197.133.108   NA                                    NA
                              2    10.197.133.108   NA                                    NA
                              4    10.197.132.43    e6c1a563-bc9e-11e0-bd1d-30e4dbc2baba  NA
                              5    10.197.132.42    e0829a21-bc61-11e0-bd1d-30e4dbc2ba66  10.197.132.42
                              12   10.197.132.46    db8b80ac-af1d-11e0-a4e7-30e4dbc26b82  10.197.132.46
                              15   10.197.132.44    7b1a5e63-bcd0-11e0-bd1d-30e4dbc2c3ae  10.197.132.44
                              
                              * this terminal session
                              switch(config)#
                               

                              Combined Upgrade of VMware vSphere and Cisco Nexus 1000V

                              You can perform a combined upgrade of VMware vSphere and Cisco Nexus 1000V.

                              If any of the hosts are running ESX 4.0 when the VSM is upgraded, the installer command displays that some VEMs are incompatible. You can proceed if you are planning a combined upgrade of the Cisco Nexus 1000V 4.2(1)SV1(4), 4.2(1)SV1(4a), 4.2(1)SV2(2.1), and ESX 4.0/4.1 to current release with ESX 5.0/5.1/5.5/6.0.


                              Note


                              Starting with the 4.2(1)SV2(2.1) release, during an VSM upgrade, if you have incompatible hosts attached to the VSM you will be allowed to upgrade from the current release of Cisco Nexus 1000V software to the later releases. You will see a warning message on incompatible host when you upgrade. Ignore the warning message and continue with the upgrade and the VSM will be upgraded to the latest version. You can perform a combined upgrade on the incompatible hosts.



                              Note


                              A combined upgrade is supported only for vCenter Server 5.0 Update 1 or later.


                              To perform a combined upgrade, follow the tasks documented in Upgrading from VMware Releases 5.x to VMware Release 6.0

                              Required Task After Upgrade—Changing the VEM Feature Level

                              After upgrading to Release 5.2(1)SV3(1.x), you must update the VEM feature level to the corresponding Release. After you perform this task, the new features in Release 5.2(1)SV3(1.x) are available on the Cisco Nexus 1000V and you have the option to increase the VLAN and port channel resource limits.

                              Before You Begin
                              • VSM and VEM have been upgraded to Release 5.2(1)SV3(1.x).

                              Procedure
                                Step 1   switch# configure terminal

                                Enters global configuration mode.

                                Step 2   switch(config)# show system vem feature level

                                Displays the current VEM feature level. The current feature level should be 5.2(1)SV3(1.x).

                                Step 3   switch(config)# vdc switch-name

                                Enters VDC configuration mode for the specified switch.

                                Step 4   switch(config-vdc)# limit-resource port-channel minimum value maximum value

                                Configures the port channel resource limit.

                                Step 5   switch(config-vdc)# limit-resource vlan minimum value maximum value

                                Configures the VLAN resource limit

                                Step 6   switch(config-vdc)# show resource

                                Displays the updated values.

                                Step 7   switch(config-vdc)# exit

                                Exists the current configuration mode.

                                Step 8   (Optional)switch(config)# copy running-config startup-config

                                Saves the change persistently through reboots and restarts by copying the running configuration to the startup configuration.


                                This example shows how to update the VEM feature level after upgrading from Release 4.2(1)SV2(1.1) to Release 5.2(1)SV3(1.x).

                                switch# configure terminal
                                Enter configuration commands, one per line.  End with CNTL/Z.
                                switch(config)# system update vem feature ?
                                  level  Updating vem feature level
                                
                                switch(config)# system update vem feature level ?
                                  <CR>
                                  <1-50>  Version number index from the list above
                                
                                switch(config)# system update vem feature level
                                Feature 					Version
                                Level 							String
                                --------------------
                                1 									4.2(1)SV2(2.1)
                                2 									4.2(1)SV2(2.2)
                                3 									4.2(1)SV2(2.3)
                                4 									5.2(1)SV3(1.1)
                                5 									5.2(1)SV3(1.2)
                                6 									5.2(1)SV3(1.3)
                                7 									5.2(1)SV3(1.4)
                                8 									5.2(1)SV3(1.5a)
                                9 									5.2(1)SV3(1.5b)
                                switch(config)#
                                switch(config)# system update vem feature level 8
                                switch(config)# copy running-config startup-config
                                

                                Simplified Upgrade Process

                                Combined Upgrade

                                You can upgrade the VEM and ESX version simultaneously. It requires vSphere version 5.0 Update1 and later versions. It is supported in Cisco Nexus 1000V Release 4.2(1)SV1(5.2) and later. This upgrade can be implemented manually or by using VUM.

                                Selective Upgrade

                                You can upgrade a selective set of VEMs and a few hosts or clusters at a time in a single maintenance window. This enables incremental upgrades during short maintenance windows. It is supported with combined upgrades of VEM and ESX, and also with manual upgrades of VEMs only. It is supported for VUM-based combined upgrades with select hosts or clusters using the GUI. It is not supported with VUM-based upgrades of VEMs alone. To upgrade manually using this procedure follow these general steps:
                                • Identify the cluster or set of hosts in a cluster.

                                • Place the selected hosts in maintenance mode (to vacate the VMs).

                                • Upgrade the VEM image on the hosts using the manual command or scripts.

                                • Take the hosts out of maintenance mode, allowing Distributed Resource Scheduler (DRS) to rebalance VMs.

                                Allowed Infrastructure Operations Under Selective Upgrade

                                These operations are allowed under selective upgrades:

                                • vMotion of VMs with the following releases:

                                  • pre-5.2(1)SV3(1.x) to 5.2(1)SV3(1.x)

                                  • 5.2(1)SV3(1.x) to pre-5.2(1)SV3(1.x)

                                  • 5.2(1)SV3(1.x) to 5.2(1)SV3(1.x)

                                  • pre5.2(1)SV3(1.x) to pre-5.2(1)SV3(1.x)

                                • VEM restart

                                • Host Reboot

                                • Add modules in 5.2(1)SV3(1.x)

                                • Add or remove ports vEth ports

                                • Shut or no-shut on port

                                • Migrate ports to or from vSwitch

                                • Add or delete VLAN or VLAN ranges

                                Background Upgrade

                                You can upgrade VEMs without a maintenance window for VEMs. You use the manual procedure to upgrade VEMs during production. Place the host in maintenance mode, upgrade the VEM, and remove the host from the maintenance mode. You do not have to shut off HA Admission Control and such (as you would during VUM upgrades). You must ensure the spare capacity in the cluster and perform a health check before the upgrade. To upgrade using this procedure follow these general steps:
                                • Upgrade the VSM first as usual. This may be done in a maintenance window

                                • Place one host at a time in maintenance mode (to vacate the VMs)

                                • Upgrade the VEM image on that host using manual commands or scripts

                                • Take the host out of maintenance mode, allowing the DRS to rebalance the VMs.

                                • Repeat the same procedure for every host in the DVS.


                                Note


                                Make sure there is enough spare capacity for HA and that all required ports have system profiles (such as mgmt vmk). Check the host health before upgrading.


                                Extended Upgrade

                                You can modify configurations between the upgrade maintenance windows. VSM configuration changes are allowed where you can add or remove modules, port configurations, VLANs, and other similar changes. If a set of hosts are upgraded to the latest VEM version using the Selective Upgrade or the Background Upgrade, the remaining set of hosts will remain in older VEM versions. During that time, various Cisco Nexus 1000V configuration changes are allowed between maintenanance windows.

                                Note


                                Do not make configuration changes during a maintenance window when the VEMs are being upgraded.


                                The list of allowed configuration changes are as follows:
                                • Add or remove modules

                                • Add or remove ports (ETH and VETH)

                                • Shut or no-shut a port

                                • Migrate ports to or from a vswitch

                                • Change port modes (trunk or access) on ports

                                • Add or remove port profiles

                                • Modify port profiles to add or remove specific features such as VLANS, ACLs, QoS, or PortSec.

                                • Change port channel modes in uplink port profiles

                                • Add or delete VLANs and VLAN ranges

                                • Add or delete static MACs in VEMs


                                Note


                                Queuing configuration changes are not supported on QoS.


                                Migrating from Layer 2 to Layer 3

                                Layer 3 Advantages

                                The following lists the advantages of using a Layer 3 configuration over a Layer 2 configuration:

                                • The VSM can control the VEMs that are in a different subnets.

                                • The VEMs can be in different subnets.

                                • Because the VEMs can be in different subnets, there is no constraint on the physical location of the hosts.

                                • Minimal VLAN configurations are required for establishing the VSM-VEM connection when compared to Layer 2 control mode. The IP address of the VEM (Layer 3 capable vmknic’s IP address) and the VSM’s control0/mgmt0 interface are the only required information.

                                • In the VSM, either the mgmt0 or the control0 interface can be used as the Layer 3 control interface. If mgmt0 is used, there is no need for another IP address as the VSM’s management IP address is used for VSM-VEM Layer 3 connection.

                                • If the management VMKernel (vmk0) is used as the Layer 3 control interface in the VEM, there is no need for another IP address because the host’s management IP address is used for VSM-VEM Layer 3 connectivity.


                                Note


                                These advantages are applicable only for ESX-Visor hosts. On ESX-Cos hosts, a new VMKernel must be created.


                                Layer 2 to 3 Conversion Tool

                                About VSM-VEM Layer 2 to 3 Conversion Tool

                                Use the VSM-VEM Layer 2 to 3 Conversion Tool as an optional, simplified method to migrate from Layer 2 to Layer 3 mode. The tool enables you to do the following:

                                • Check whether the prerequisites are met for the migration from L2 to L3 mode.

                                • Migrate the VSM from Layer 2 to Layer 3 Mode, with user interaction.

                                  In the process of migration, the tool creates a port profile. You can use port profiles to configure interfaces, which you can assign to other interfaces to give them the same configuration. The VSM-VEM Layer 2 to 3 Conversion Tool also gives you the option of retrieving the IP addresses from a local file (static).

                                Prerequisites for Using VSM-VEM Layer 2 to 3 Conversion Tool

                                The L2-L3_CT.zip file contains the applications required to run VSM-VEM Layer 2 to 3 Conversion Tool

                                Before you begin:

                                • Log in as administrator to use this conversion tool script.

                                • Download the L2-L3_CT.zip file from the CCO Download Center.
                                • Install Tool Conversion Language (TCL) version 8.4 or later on the workstation.
                                • Install VMware PowerShell API version 5.0 or later on both the vCenter and the workstation.
                                • Install OpenSSH on the workstation.
                                • In the workstation environment variables, add installation_directory_for_OpenSSH\bin directory to the end of the Windows path variable.

                                • Ensure that VLANs are allowed on the uplinks.


                                Note


                                You must install vCenter, VSM, and OpenSSH with admin privileges.

                                Using VSM-VEM Layer 2 to 3 Conversion Tool

                                Procedure
                                  Step 1   On your workstation, unzip the L2-L3_CT.zip file to any folder.

                                  When you unzip the file, a Pre-Migrate-Check-Logs folder is created that holds all the running logs. Debugging log files will be created in this folder.

                                  Step 2   Inside the L2-L3_CT folder, run migration.bat as an administrator. This starts the VSM-VEM Layer 2 to 3 Conversion Tool.
                                  Step 3   Enter the VSM IP address.
                                  Step 4   Enter the VSM username.
                                  Step 5   Enter the vCenter IP.
                                  Step 6   Enter the vCenter username.
                                  Step 7   Enter the VSM password.
                                  Step 8   Enter the vCenter password.

                                  The migration tool begins creating the .csv file for the user, and then checks for a port profile with layer 3 capability.

                                  Step 9   If there is no layer 3-capable port profile, the tool will prompt for the creation of one. If you don't want to create a layer-3 capable port profile, skip to the next step.
                                  1. Enter yes to confirm when asked to create 1 layer 3-capable port profile.
                                  2. Enter a layer 3 port profile name.
                                  3. Enter access VLAN ID

                                  This creates a port profile with the required configuration. You can select this port profile when prompted by the tool. The migration tool checks for connectivity between VSM, vCenter, and VEM modules. Wait for the message to display that all connectivity is fine.

                                  Step 10   Enter yes to continue when asked if you want to continue.

                                  The migration tool proceeds to create an extract .csv file.

                                  Step 11   Open the extract.csv file (in C:\Windows\Temp).
                                  Step 12   Enter the vmknic IP details at the end of the text, delimited by semicolons, and save the file as convert.csv.
                                  Step 13   Press any key to continue.
                                  Step 14   Enter yes to confirm when asked if you are sure you completed the required steps.
                                  Step 15   Enter the VSM password.
                                  Step 16   Enter the vCenter password.

                                  The migration tool connects to the vCenter and VSM of the user.

                                  Step 17   Enter yes to confirm when asked if you want to continue.

                                  The migration process continues.

                                  Step 18   Enter the port profile name from the list of port profiles that appears at the prompt.

                                  Once the port profile is selected, the max port value is automatically changed to 128.

                                  Step 19   Enter yes to confirm when asked if you have updated convert.csv file as per the instructions.
                                  Step 20   Enter yes to confirm, when asked if you want to continue.

                                  The tool checks the connectivity between VSM, vCenter, and VEM modules. A message is displayed that the addition to vmknics are successful and all connectivity is fine. The VmkNicAddingToHost window will remain open until the configuration is complete.

                                  Step 21   Enter yes to confirm that you would like to proceed with mode change from L2 to L3.
                                  Step 22   Enter yes to confirm when asked if you wish to continue.

                                  Wait for the SUCCESSFULLY COMPLETED MIGRATION message to display. The migration from layer 2 to layer 3 is now complete. The operating mode should now be listed as L3.


                                  Using Extract Mode

                                  You can use Extract Mode to extract the attached VEM states and save them to the Extract.csv file, which is located in C:\Windows\Temp.

                                  Procedure
                                     Command or ActionPurpose
                                    Step 1 Choose extract mode when prompted by VSM-VEM Layer 2 to 3 Conversion Tool. You can now view the data in the Extract.csv file in the Windows temp folder of your workstation.  

                                    This mode will not migrate the VSM.

                                     

                                    Using Convert Mode

                                    You can use Convert Mode to migrate the VSM from Layer 2 to Layer 3.

                                    Procedure
                                       Command or ActionPurpose
                                      Step 1Rename the Extract.csv file to Convert.csv  

                                      The migration tool will retrieve the data from the Convert.csv file.

                                       
                                      Step 2Populate your Convert.csv file (in C:\Windows\Temp) with the vmknic IP address and netmask.    
                                      Step 3Run migration.bat.  

                                      This will migrate the VSM mode from Layer 2 to Layer 3 .

                                       

                                      Example

                                      The following example shows how to use the VSM-VEM Layer 2 to 3 Conversion Tool.

                                      Enter VSM IP:
                                      enter VSM Username:
                                      Enter VC IP:
                                      enter VC Username:
                                      Enter VSM password:
                                      Enter VC password:
                                      create the Csv File for User I/P: C:\windows\temp\extract.csv
                                      #### VSM DETAILS STARTS ##########
                                      .........
                                      .............
                                      #### VC DETAILS END ##########
                                      .............
                                      ................
                                      Operating Mode : L2
                                      Operatoinal Mode is L2 Currently ......
                                      ###############################################################################
                                      List of port profiles on VSM:
                                      -----------------------------
                                      ###############################################################################
                                      =========
                                       CHECK 1: Checking for a port profile with capability l3control set and Enabled.
                                      ................
                                      =========
                                      There is not even One L3 Capable Port Profile
                                      
                                      Do you want to Create One L3 Capable Port Profile
                                      Please Give Option (Yes/No):Yes
                                      Please Enter L3 PortProfile Name: L3-Control
                                      Please Give Access Vlan Id :5
                                      Creating L3 Port Profile : L3-Control with Access Vlan : 5
                                      ……………………………….
                                      ………………………………………………..
                                      L3 capable port profiles: L3-Control
                                      Modules Registered:[10.105.228.116]
                                      =========
                                       CHECK 3:  Checking for connectivity between VSM and VC, VSM and VEM Modules
                                      =========
                                      …………………..
                                      ……………………………………
                                      
                                      ## All connectivity is fine
                                      ###############################################################################
                                      Please wait for a few minutes.
                                      Do you want to Continue,Please Type ....(yes/no):yes
                                      Migration Tool Proceeding ....
                                      Creating csv file: C:\windows\temp\extract.csv
                                      Modules : 10.105.228.116
                                      #########################################################
                                      Modules Registered:[3 10.105.228.116]
                                      #########################################################
                                      
                                      #########################################################
                                      ###########################################################################
                                      Extraction of VEM connection status has been dumped in: C:\windows\temp\extract.
                                      csv
                                      Please rename this file before using Convert Mode
                                      Update the VMKNic IP and NetMask for all disconnected entries
                                      ###########################################################################
                                      !###############################################################################
                                      ########!
                                      !Open c:\windows\temp\Extract.csv and save as Convert.csv (in the same directory
                                      )
                                      !Enter the VMKNic IP and netmask in the Convert.csv file as shown below
                                      !VEM_Host_IP;PPConnectionStatus;Vem_Vmk_IP;NetMask!
                                      !PPConnectionStatus Should not be changed!
                                      !10.10.10.12;DisConnected;10.10.10.100;255.255.255.0!
                                      !After Updating the IP and Netmask, save the file in the same directory
                                      !###############################################################################
                                      ########!
                                      Press any key to continue . . .
                                      Are you sure you completed the above steps? (yes/no):yes
                                      
                                      ##############################################################################
                                      
                                      ##Tool expects this File have an IP/Netmask given for disconnected VEM in the co
                                      rrect format : C:\windows\temp\Convert.csv
                                      
                                      ##10.10.10.12;DisConnected;10.10.10.100;255.255.255.0
                                      
                                      ###############################################################################
                                      VSM password required 10.105.228.115:
                                      
                                      VC password required 10.105.228.113:
                                      
                                      create the Csv File for User I/P: C:\windows\temp\extract.csv
                                      ……………………..
                                      …………………………….
                                      ## All connectivity is fine
                                      
                                      ###############################################################################
                                      Please wait for a few minutes.
                                      Do you want to Continue,Please Type ....(yes/no):yes
                                      Migration Tool Proceeding ....
                                      ……………………………
                                      ……………………………………………….
                                      #########################################################
                                      Name the port profile you want to proceed with : [l3-pp]
                                      Please type any port profile mentioned above       ||:l3-pp
                                      You Selected : l3-pp
                                      …………………..
                                      ……………………………….
                                      ###################################################################
                                      ## Have you created a Convert.csv file with a proper VMKNic IP and NetMask?
                                      ## In the C:\windows\temp\Convert.csv file for disconnected VEMs.
                                      ###################################################################
                                      Have you Updated C:\windows\temp\Convert.csv as per the above instructions?(Yes)
                                      :yes
                                      Do you want to Continue,Please Type ....(yes/no):yes
                                      Migration Tool Proceeding ....
                                      ………………………….
                                      ……………………………………………..
                                      
                                      Addition to VmKNics are successful
                                      ## All connectivity is Fine
                                      ……………………………
                                      …………………………………..
                                      ###############################################################################
                                      
                                      Would You Like to Proceed with Mode Change from L2 to L3....(yes/no):yes
                                      Do you want to Continue,Please Type ....(yes/no):yes
                                      Migration Tool Proceeding ....
                                      …………………..
                                      ……………………..
                                      switch#
                                      Operating Mode : L3
                                      Operatoinal Mode is L3 Currently
                                      Svs Connection Mode : L3
                                      Vem IP : 10.10.10.108 Connected Back
                                      ………………
                                      ……………………
                                      All VEMs are back: pass
                                       ==============SUCCESSFULLY COMPLETED MIGRATION===========================
                                      

                                      Interface Comparisons Between mgmt0 and control0

                                      The following describes the differences between using a mgmt0 interface or a control0 interface:

                                      • On the VSM, there are two ways of connectivity via the mgmt0 or control0 interface.

                                      • Setting mgmt0 as Layer 3 interface uses the mgmt0 interface on the VSM.

                                      • The control0 interface is a special interface created for Layer 3 connectivity.

                                      • The Layer 3 interface on the VEM is selected by designating the interface with the Layer 3 control capability.

                                      • The egress control traffic route is decided by the VMware routing stack.

                                      • On a VEM, the management vmknic (vmk0) can be used for Layer 3 control connectivity if it is managed by the Cisco Nexus 1000V and is designated with the Layer 3 control capability.

                                      Configuring the Layer 3 Interface

                                      Configure either the control0 (see Step 1) or mgmt0 interface (see Step 2).

                                      Procedure
                                        Step 1   Configuring the control0 interface.
                                        Note   

                                        When using control0 as the control interface on the VSM, the control0 interface must be assigned with an IP address.

                                        1. Configure the IP address.
                                          switch# configure terminal 
                                          switch(config)# interface control 0 
                                          switch(config-if)# ip address 5.5.5.2 255.255.255.0 
                                        2. Display the running configuration of the control0 interface.
                                          switch# show running-config interface control 0 
                                          !Command: show running-config interface control0 
                                          !Time: Mon Dec 12 02:41:47 2011 
                                          version 4.2(1)SV1(5.1) 
                                          interface control0 
                                            ip address 5.5.5.2/24 
                                        Step 2   Configure the mgmt0 interface.
                                        Note   

                                        When using mgmt0 as the control interface, no configuration on the VSM is required as the mgmt0 interface is assigned with the host’s management IP address.

                                        1. Display the running configuration of the mgmt0 interface.
                                        switch# show running-config interface mgmt 0 
                                        !Command: show running-config interface mgmt0 
                                        !Time: Mon Dec 12 02:43:25 2011 
                                        version 4.2(1)SV1(5.1) 
                                        interface mgmt0 
                                          ip address 10.104.249.37/27 

                                        Creating a Port Profile with Layer 3 Control Capability

                                        Before You Begin
                                        • You are creating a port profile with Layer 3 control capability.

                                        • Allow the VLAN that you use for VSM to VEM connectivity in this port profile.

                                        • Configure the VLAN as a system VLAN.


                                        Note


                                        VEM modules will not register to the VSM before a vmkernel interface (vmk) is migrated to a Layer 3 control capable port profile. You must migrate a vmk to the Layer 3 port profile after migrating host vmnics to Ethernet port profiles. Migrate your management vmkernel interface into the Layer 3 capable port profile. Do not use multiple vmkernel interfaces on the same subnet.


                                        Procedure
                                          Step 1   Create a Layer 3 port profile.
                                          VSM_1# configure terminal 
                                          VSM_1(config)# port-profile type vethernet l3_control 
                                          VSM_1(config-port-prof)# switchport mode access 
                                          VSM_1(config-port-prof)# switchport access vlan 3160 
                                          VSM_1(config-port-prof)# capability l3control 
                                          VSM_1(config-port-prof)# vmware port-group 
                                          VSM_1(config-port-prof)# state enabled 
                                          VSM_1(config-port-prof)# no shutdown 
                                          Step 2   Display the port profile.
                                          VSM_1# show port-profile name l3_control 
                                          port-profile l3_control
                                           type: Vethernet
                                           description: 
                                           status: enabled
                                           max-ports: 32
                                           min-ports: 1
                                           inherit:
                                           config attributes:
                                            switchport mode access
                                            switchport access vlan 3160 (Allow the VLAN in access mode.) 
                                            no shutdown
                                           evaluated config attributes:
                                            switchport mode access
                                            switchport access vlan 3160
                                            no shutdown
                                           assigned interfaces:
                                            Vethernet1
                                           port-group: l3_control 
                                           system vlans: 3160 (Configure the VLAN as a system VLAN.) 
                                           capability l3control: yes (Configure capability l3 control.) 
                                           capability iscsi-multipath: no
                                           capability vxlan: no
                                           capability l3-vn-service: no
                                           port-profile role: none port-binding: static

                                          Creating a VMKernel on the Host

                                          Procedure
                                            Step 1   Log in to the vCenter Server.
                                            Step 2   Choose Home > Inventory > Hosts and Clusters.
                                            Step 3   Choose the host.
                                            Step 4   Click the Configuration tab.
                                            Step 5   In the Hardware pane, choose Networking.
                                            Step 6   Click the vSphere Distributed Switch button.
                                            Step 7   Go to Manage Virtual Adapters.
                                            Step 8   Add and create a new VMKernel.
                                            Note   

                                            The management vmkernel can also be used as a Layer 3 control interface. For ESX-Visor hosts only. Migrate your management vmkernel interface into the Layer 3 capable port profile. Do not use multiple vmkernel interfaes on the same subnet.

                                            Step 9   Assign the VMkernel to the port profile created in Creating a Port Profile with Layer 3 Control Capability.
                                            Step 10   Assign an IP address.

                                            Configuring the SVS Domain in the VSM

                                            Before You Begin

                                            The control0 or mgmt0 interface can be assigned as the Layer 3 control interface.

                                            Procedure
                                              Step 1   Disconnect the VSM to vCenter Server connection.
                                              switch# configure terminal 
                                              switch(config)# svs connection toVC 
                                              switch(config-svs-conn)# no connect 
                                              switch(config-svs-conn)# exit 
                                              Step 2   (Optional)Remove the control and the packet VLAN configuration.
                                              switch(config)# svs-domain 
                                              switch(config-svs-domain)# no control vlan 
                                              switch(config-svs-domain)# no packet vlan 
                                              Step 3   Change the svs mode from Layer 2 to Layer 3 with the mgmt0 interface as the Layer 3 control interface.
                                              switch(config-svs-domain)# svs mode l3 interface mgmt0 
                                              switch(config-svs-domain)# exit 
                                              Note   

                                              If the control0 interface is being used as the Layer 3 control interface, enter the svs mode l3 interface control0 command:

                                              Step 4   Restore the VSM to vCenter Server connection.
                                              switch(config)# svs connection toVC 
                                              switch(config-svs-conn)# connect 
                                              switch(config-svs-conn)# end 
                                              Note   

                                              After entering the svs connection toVC command, the module is detached and reattached in Layer 3 mode. If this delay is more than six seconds, a module flap occurs. This does not affect the data traffic.

                                              Step 5   Display the SVS domain configuration.
                                              switch# show svs domain 
                                              SVS domain config: 
                                                Domain id:    3185 
                                                Control vlan: NA  
                                                Packet vlan:  NA  
                                                L2/L3 Control mode: L3 
                                                L3 control interface: mgmt0
                                                Status: Config push to VC successful.
                                              