Specifications
This appendix provides cable and technical specifications for the Catalyst 4900 series switches.
Console Port
The console port is an RJ-45 receptacle. The Request to Send (RTS) signal tracks the state of the Clear to Send (CTS) input. Table A-1 lists the console port pinouts.
Note A console cable is not provided in the accessory kit. It can be ordered as an option.
Table A-1 Console Port Pinouts
|
|
|
|
1 |
RTS |
output |
request to send |
2 |
DTR |
output |
data terminal ready |
3 |
TXD |
output |
transmit data |
4 |
GND |
— |
— |
5 |
GND |
— |
— |
6 |
RXD |
input |
receive data |
7 |
DSR |
input |
data set ready |
8 |
CTS |
input |
clear to send |
Management Port
The 10/100BASE-T (Catalyst 4948) or 10/100/1000BASE-T (Catalyst 4948-10GE) management port use an RJ-45 receptacle with a Link Status LED. Table A-2 lists the 10/100BASE-T port pinouts.
Table A-2 10/100BASE-T Port Pinouts
|
|
|
|
1 |
RXDP |
input |
receive data |
2 |
RXDN |
input |
receive data |
3 |
TXDP |
output |
transmit data |
4 |
unused |
— |
— |
5 |
unused |
— |
— |
6 |
TXDN |
output |
transmit data |
7 |
unused |
— |
— |
8 |
unused |
— |
— |
Table A-3 lists the 10/100/1000BASE-T port pinouts.
Table A-3 10/100/1000 BASE-T Port Pinouts
|
|
|
1 |
TXRX0P |
Bidirectional data pair 0 |
2 |
TXRX0N |
Bidirectional data pair 0 |
3 |
TXRX1P |
Bidirectional data pair 1 |
4 |
TXRX2P |
Bidirectional data pair 2 |
5 |
TXRX2N |
Bidirectional data pair 2 |
6 |
TXRX1N |
Bidirectional data pair 1 |
7 |
TXRX3P |
Bidirectional data pair 3 |
8 |
TXRX3N |
Bidirectional data pair 3 |
Catalyst 4900 Series Switch Specifications
Table A-4 shows Catalyst 4900 series switch specifications.
Table A-4 Catalyst 4900 Series Switch Specifications
|
|
|
Temperature, ambient operating ambient nonoperating and storage |
32°F (0°C) to 104°F (40°C) -40 to 167°F (-40 to 75°C) |
Humidity (RH), ambient (noncondensing) operating nonoperating and storage |
10% to 90% 5% to 95% |
Altitude operating and nonoperating |
-60 to 2000 m |
Switch heat dissipation |
1023 BTU/hour (Catalyst 4928-10GE) 600 BTU/hour (Catalyst 4948) 723 BTU/hour (Catalyst 4948-10GE) |
System power dissipation |
150 W (Catalyst 4928-10GE) 200 W (Catalyst 4948) 211 W (Catalyst 4948-10GE) |
|
Memory |
256-MB SDRAM, 64-MB Flash, 256 bytes serial EEROM (all fixed and not upgradeable) |
|
Dimensions (H x W x D) |
1.75 x 17.5 x 16 in. (4.5 x 44.5 x 40.6 cm) |
Weight |
17.5 lb (7.9 kg) for a system with two power supplies, 2.0 lb (0.9 kg) per power supply |
Airflow |
Sides in, rear out |
|
Minimum input |
85 VAC |
Power supply output |
300 W |
AC-input |
4 A maximum @ 100 VAC 2 A maximum @ 240 VAC |
AC frequency |
50 to 60 Hz |
Output current |
25 A max |
Peak current |
4 A max @ 100 VAC 2 A max @ 240 VAC |
Inrush value |
20 A for one cycle of AC |
Output voltage |
12 V |
Input KVA rating |
0.375 KVA |
|
Minimum input |
-40.5 VDC |
Power supply output |
300 W |
DC-input |
8 A @ -48 to -60 VDC |
Output current |
25 A max |
Peak current |
8 A @ -48 to -60 VDC |
Inrush value |
Cold turn on (PSU off for > 1 hour) - 45 A Hot turn on (PSU on for > 1 hour) - 90 A |
Output voltage |
12 V |
Input KVA rating |
0.4 KVA |