CIMC NICs
Two NIC modes are available for connection to the CIMC.
Note |
In the case of M3 modules, GE2 and GE3 will be replaced by TE2 and TE3. |
NIC Mode
-
Dedicated—A connection to the CIMC is available through the management Ethernet port or ports.
-
Shared LOM—A connection to the CIMC is available through the LAN On Motherboard (LOM) Ethernet host ports and through the router's PCIe and MGF interfaces.
Note
In shared LOM mode, all host ports must belong to the same subnet.
The following examples show the link state:
E160S /cimc/network # show link-state
Interface State
------------------------------ --------------------
Console Link Detected
GE1 Link Detected
TE2 Link Detected
TE3 Link Detected
Dedicated No Link Detected
E1120D /cimc/network # show link-state
Interface State
------------------------------ --------------------
Console Link Detected
GE1 Link Detected
TE2 No Link Detected
TE3 No Link Detected
The following examples show the LOM MAC list:
E160S /cimc/network # show lom-mac-list
Interface MAC Address
------------------------------ --------------------
Console 00:f6:63:b9:65:d4
GE1 00:f6:63:b9:65:d5
TE2 00:f6:63:b9:65:d6
TE3 00:f6:63:b9:65:d7
E1120D /cimc/network # show lom-mac-list
Interface MAC Address
------------------------------ --------------------
Console 28:6f:7f:ee:ac:0a
GE1 28:6f:7f:ee:ac:0b
TE2 28:6f:7f:ee:ac:0c
TE3 28:6f:7f:ee:ac:0d