Size |
12.0 in. x 7.8 in. x 6.4 in. (30.48 cm x 19.81 cm x 16.26 cm) (including antenna mount) |
Weight |
- 1552SA/1552SD (AC): 18.5 lbs (8.4 kg)
- 1552SA/1552SD (DC): 17.5 lbs (7.9)
- 1552H: 17.6 lbs (8 kg)
- 1552WU: 17.6 lbs (8 kg)
- Pole mounting bracket: 6.1 lbs (2.8 kg)
|
Connector |
- 1552H: Three Type N antenna connectors for 2.4 GHz radio and 5 GHz 802.11n radio (depends on configuration)
- 1552S: Five Type N antenna connectors for 2.4 GHz radio and 5 GHz 802.11n radio (depends on configuration)
- 1552WU: Seven Type N antenna connectors for 2.4 GHz radio and 5 GHz 802.11n radio (depends on configuration)
- 1552S: Two Type N antenna connector (2.4 GHz ISA100 Wireless and WirelessHART Multiprotocol radio)
- Internal PoE In or ETH connector (uplink port)—RJ-45 connector
- Internal PoE Out connector (downlink port)—RJ-45 connector
- 1552H and 1552S: Optional internal SFP fiber module—LC fiber connector
- 1552WU: 2.4 GHz WirelessHART radio for communicating with sensor devices by a single Type N connector for the WirelessHART 2.4 GHz antenna. This antenna is intended to be connected using a low-loss coaxial cable.
|
Power sources (see Table D-2 for power distribution budget) |
- 100 to 240 VAC, 50–60 Hz (1552H and 1552SA only)
- Power over Ethernet (PoE): 56 VDC (1552H only)
- 12 VDC input (not supported in hazardous locations environment)
- 24 VDC (1552SD and 1552WU)
|
Operating temperature |
-40 to 55°C (-40 to 131°F) plus Solar Loading |
Storage temperature |
-50 to 85°C (-58 to 185°F) |
Humidity |
Access point: 0 to 100% condensing—access point (operating and nonoperating) Power injector: 10 to 90% noncondensing—power injector (operating) |
Data rates |
802.11a: 6, 9, 12, 18, 24, 36, 48, and 54 Mbps |
802.11b: 1, 2, 5.5, and 11 Mbps |
802.11g: 6, 9, 12, 18, 24, 36, 48, and 54 Mbps |
802.11n data rates (2.4 GHz and 5 GHz) - refer to Table D-3 for data rates |
Environmental ratings |
- IP67 (1552H, 1552SA/1552SD, and 1552WU)
- NEMA Type 4X (1552H and 1552SA/1552SD)
- NEMA Type 4 (1552WU)
|
Maximum elevation |
6,561 ft (2,000 m) at 131 o F (55 o C)—Operating 16,000 ft (4,877 m) at –13 o F (–25 o C)—Non-operating |
Wind resistance |
Wind resistance:
- Up to 100 MPH sustained winds
- Up to 165 MPH wind gusts
|
RF output power |
2.4 GHz
– 28 dBm with 2 antennas
- 802.11g (non HT duplicate mode)
– 28 dBm with 2 antennas
– 28 dBm with 2 antennas 5 GHz
– 28 dBm with 2 antennas
- 802.11n non-HT duplicate (802.11a duplicate) mode
– 28 dBm with 2 antennas
– 27 dBm with 2 antennas
- 802.11n (HT40)
- 27 dBm with 2 antennas
Note Maximum output depends on the regulatory domain in which the access point is installed. For additional information, refer to the Appendix C, “Channels and Power Levels”.
|
Frequency Band and 20-MHz Operating Channels |
-A Domain:
- 2.400 to 2.4835 GHz; 11 channels
- 5.725 to 5.850 GHz; 5 channels
-B Domain:
- 2.400 to 2.4835 GHz, 11 channels
- 5.260 to 5.320 GHz; 4 channels
- 5.500 to 5.560 GHz, 4 channels
- 5.680 to 5.720 GHz, 3 channels
- 5.745 to 5.825 GHz, 5 channels
-C Domain:
- 2.400 to 2.4835 GHz; 13 channels
- 5.725 to 5.850 GHz; 5 channels
-E Domain:
- 2.401 to 2.4835 GHz; 13 channels
- 5.470 to 5.725 GHz; 8 channels
-K Domain:
- 2.400 to 2.4835 GHz; 11 channels
- 5.250 to 5.825 GHz; 14 channels
-M Domain
- 2.400 to 2.4835 GHz; 13 channels
- 5.470 to 5.850 GHz; 12 channels
-N Domain:
- 2.400 to 2.4835 GHz; 11 channels
- 5.725 to 5.850 GHz; 5 channels
-Q Domain:
- 2.400 to 2.4835 GHz; 13 channels
- 5.470 to 5.725 GHz; 11 channels
-R Domain:
- 2.400 to 2.4835 GHz; 13 channels
- 5.250 to 5.725 GHz; 11 channels
-S Domain:
- 2.400 to 2.4835 GHz; 13 channels
- 5.725 to 5.850 GHz; 5 channels
-T Domain:
- 2.400 to 2.4835 GHz; 11 channels
- 5.470 to 5.850 GHz; 16 channels
|
Immunity |
- Less than or equal to 5 mJ for 6kV/3kA @ 8/20 ms waveform
- ANSI/IEEE C62.41
- EN61000 4-5 Level 4 AC Surge Immunity
- EN61000 4-4 Level 4 Electrical Fast Transient Burst Immunity
- EN61000 4-3 Level 4 EMC Field Immunity
- EN61000 4-2 Level 4 ESD Immunity
|
Safety |
- IEC 60950-1
- UL 60950-1
- CSA 60950-1
- EN 60950-1
|
Hazardous Locations |
- ANSI/ASA 12.12.01
- UL 60079-0
- UL 60079-15
- CSA C22.2 No. 213-M1987
- CAN/CSA E60079-15/-0
- EN 60079-0
- EN 60079-15
- IEC 60079-0
- IEC 60079-15
Note For more information about Hazardous Location Specifications, see Compliance. |
Radio approvals |
- FCC Parts 15.247, 90.210
- FCC Bulletin OET-65C
- Canada RSS-210 and RSS-102
- AS/NZS 4268.2003
|
EMI and susceptibility 1552S and 1552H |
Powered by AC (AP1552S):
- FCC Part 15.107 and 15.109 Class B
- ICES-003 Class B (Canada)
- EN 55022 B
- EN 60601-1-2:2001
- AS/NZS 3548 Class B
- VCCI Class B
- EN 301.489-1
- EN 301.489-17
|
Powered by power injector (AP1552S and AP1552H); Powered by AC (AP1552H):
- FCC Part 15.107 and
15.109 Class A
- ICES-003 Class A
(Canada)
- EN 55022 A
- EN 60601-1-2:2001
- AS/NZS 3548 Class A
- VCCI Class A
- EN 301.489-1
- EN 301.489-17
|
EMI and susceptibility 1552WU |
- FCC part 15.107, 15.109
- ICES-003
- EN 301 489-1, -17
|
|
|