Enables or disables the Smart Call Home alert-group.
Privilege
Security Administrator, Administrator
Mode
Exec > Global Configuration > Call-Home Configuration
configure > call-home
Entering the above command sequence results in the following prompt:
[local]host_name(config-call-home)#
Syntax
[ default | no ] alert-group { all | configuration | crashinfo | diagnostic | environment | inventory | syslog }
default
Configures the alert-group back to default settings. The default is
enabled.
no
Disables the alert-groups.
alert-group all
Enables an alert group for all categories.
alert-group configuration
Enables an alert group related to configuration.
alert-group crashinfo
Enables an alert group related to crashes.
alert-group diagnostics
Enables an alert group related to diagnostics.
alert-group environment
Enables an alert group related to environment. These typically include
events related to power, fan, and temperature alarms.
alert-group inventory
Enables an alert group related to inventory. This is a non-critical
event that could include notifications when cards are inserted or removed, or
when the system is cold-booted.
alert-group syslog
Enables an alert group related to syslog. This includes events
generated by the syslog PORT facility.
Usage Guidelines
An alert group is a predefined subset of Smart Call Home alerts that
are supported on this device. Alert groups allow you to select the set of Smart
Call Home alerts that you want to send to a predefined or custom destination
profile.
Example
The following command enables alerts for all of the preconfigured
Smart Call Home alerts:
alert-group all