Table Of Contents
Configuring Fabric Configuration Servers
About FCS
Significance of FCS
Configuring FCS
Displaying FCS Information
Configuring Fabric Configuration Servers
This chapter describes the Fabric Configuration Server (FCS) feature provided in switches in the Cisco MDS 9000 Family. It includes the following sections:
•About FCS
•Configuring FCS
•Displaying FCS Information
About FCS
The Fabric Configuration Server (FCS) provides discovery of topology attributes and maintains a repository of configuration information of fabric elements. A management application is usually connected to the FCS on the switch through an N port. The FCS views the entire fabric based on the following objects:
•Interconnect element (IE) object: Each switch in the fabric corresponds to an IE object. One or more IE objects form a fabric.
•Port object: Each physical port in an IE corresponds to a port object. This includes the switch ports (xE, Fx, and TL ports), and its attached Nx ports.
•Platform object: A set of nodes may be defined as a platform object to make it a single manageable entity. These nodes are end-devices (host systems, storage subsystems) attached to the fabric. platform objects reside at the edge switches of the fabric.
Each object has its own set of attributes and their values. A null value may also be defined for some attributes.
In the Cisco MDS 9000 Family switch environment, multiple VSANs constitute a fabric, where one instance of the FCS is present per VSAN.
If you have attached a management application to a switch, all the frames directed towards the FCS in the switch is a part of the port VSAN in the switch port (Fx port). Hence your view of the management application is limited only to this VSAN. However information about other VSANs that this switch is part of can be obtained either through SNMP or CLI.
In Figure 2 Management Application 1 (M1) is connected through an F port with a port VSAN ID 1 and Management Application 2 (M2) is connected through an F port with a port VSAN ID 2. M1 can query FCS info of switches S1 and S3, and M2 can query switches S3 and S4. Switch S2 information is not known to both of them. FCS operations can be done only on those switches that are visible in the VSAN. Note that M2 can send FCS requests only for VSAN 2 even though S3 is also a part of VSAN 1.
Figure 24-1 FCSs in a VSAN Environment
Significance of FCS
•Network Management
–N port management application can query and obtain information about the fabric elements.
–SNMP Manager—A SNMP Manager can use the FCS management information base (MIB) to start discovery and obtain information about the fabric topology.
•The FCS supports TE and TL ports in addition to the standard F and E ports.
•The FCS can maintain a group of modes with a logical name and management address when a platform registers with it. FCS maintains a backup of all registrations in secondary storage and updates it with every change. When a restart or switchover happens, FCS will retrieve the secondary storage information, and rebuild its database.
•The SNMP manager can query FCS for all the IEs, ports, and platforms in the fabric.
Configuring FCS
Use the fcs plat-check-global command to specify if the platform name or node name uniqueness verification is for the entire fabric (globally) or only for locally (default) registered platforms.
Note Set this command globally only if all switches in the fabric belong to the Cisco MDS 9000 Family.
To enable global checking of the platform name, follow these steps:
|
Command
|
Purpose
|
Step 1
|
|
Enters configuration mode.
|
Step 2
|
switch(config)# fcs plat-check-global vsan 1
|
Enables global checking of platform name.
|
switch(config)# no fcs plat-check-global vsan 1
|
Disables (default) global checking of platform name.
|
To register platform attributes, follow these steps:
|
Command
|
Purpose
|
Step 1
|
|
Enters configuration mode.
|
Step 2
|
switch(config)# fcs register
switch(config-fcs-register)#
|
Enters the FCS registration submode
|
Step 3
|
switch(config-fcs-register)# platform name
SamplePlatform vsan 1
switch(config-fcs-register-attrib)#
|
Enters the FCS registration attributes submode.
|
switch(config-fcs-register)# no platform name
SamplePlatform vsan 1
switch(config-fcs-register)#
|
Deletes a registered platform.
|
Step 4
|
switch(config-fcs-register-attrib)# mgmt-addr
1.1.1.1
switch(config-fcs-register-attrib)#
|
Configures the platform management address.
|
switch(config-fcs-register)# no mgmt-addr
1.1.1.1
switch(config-fcs-register)#
|
Deletes all management addresses on the platform.
|
Step 5
|
switch(config-fcs-register-attrib)# nwwn
11:22:33:44:55:66:77:88
switch(config-fcs-register-attrib)#
|
Configures the platform node name.
|
switch(config-fcs-register)# no nwwn
11:22:33:44:55:66:77:88
switch(config-fcs-register)#
|
Deletes the platform node name.
|
Step 6
|
switch(config-fcs-register-attrib)# type 5
switch(config-fcs-register-attrib)#
|
Configures the fc-gs-3 defined platform type.
|
switch(config-fcs-register)# no type 5
switch(config-fcs-register)#
|
Deletes the configured type and reverts the switch to its factory default of unknown type.
|
Step 7
|
switch(config-fcs-register-attrib)# exit
switch(config-fcs-register)#
|
Exits the FCS registration attributes submode
|
Step 8
|
switch(config-fcs-register)# exit
|
Exits the FCS registration submode.
|
Displaying FCS Information
Use the show fcs commands to display the status of the WWN configuration (see Example 24-1 to 24-9).
Example 24-1 Displays FCS Local Database Information
switch# show fcs database
FCS Local Database in VSAN: 1
------------------------------
Switch WWN : 20:01:00:05:30:00:16:df
Switch Domain Id : 0x7f(127)
Switch Mgmt-Addresses : snmp://172.22.92.58/eth-ip
http://172.22.92.58/eth-ip
Fabric-Name : 20:01:00:05:30:00:16:df
Switch Logical-Name : 172.22.92.58
Switch Information List : [Cisco Systems*DS-C9509*0*20:00:00:05:30:00
-------------------------------------------------------------------
Interface pWWN Type Attached-pWWNs
-------------------------------------------------------------------
fc2/1 20:41:00:05:30:00:16:de TE 20:01:00:05:30:00:20:de
fc2/2 20:42:00:05:30:00:16:de Unknown None
fc2/17 20:51:00:05:30:00:16:de TE 20:0a:00:05:30:00:20:de
FCS Local Database in VSAN: 5
------------------------------
Switch WWN : 20:05:00:05:30:00:12:5f
Switch Domain Id : 0xef(239)
Switch Mgmt-Addresses : http://172.22.90.171/eth-ip
snmp://172.22.90.171/eth-ip
http://10.10.15.10/vsan-ip
snmp://10.10.15.10/vsan-ip
Fabric-Name : 20:05:00:05:30:00:12:5f
Switch Logical-Name : 172.22.90.171
Switch Information List : [Cisco Systems*DS-C9509**20:00:00:05:30:00:12:5e]
-------------------------------------------------------------------
Interface pWWN Type Attached-pWWNs
-------------------------------------------------------------------
fc3/1 20:81:00:05:30:00:12:5e TE 22:01:00:05:30:00:12:9e
fc3/2 20:82:00:05:30:00:12:5e TE 22:02:00:05:30:00:12:9e
fc3/3 20:83:00:05:30:00:12:5e TE 22:03:00:05:30:00:12:9e
Example 24-2 Displays a List of All IEs for a Specific VSAN
switch# show fcs ie vsan 1
-------------------------------------------------------------------
-------------------------------------------------------------------
20:01:00:05:30:00:16:df Switch (Local) 0xfffc7f
20:01:00:05:30:00:20:df Switch (Adjacent) 0xfffc64
Example 24-3 Displays Interconnect Element Object Information for a Specific nWWN
switch# show fcs ie nwwn 20:01:00:05:30:00:16:df vsan 1
Fabric-Name = 20:01:00:05:30:00:16:df
Logical-Name = 172.22.92.58
Management Address List =
snmp://172.22.92.58/eth-ip
http://172.22.92.58/eth-ip
Vendor-Name = Cisco Systems
Model Name/Number = DS-C9509
Example 24-4 Displays Platform Information for a Specific Platform
switch# show fcs platform name SamplePlatform vsan 1
Platform Management Addresses:
Example 24-5 Displays a List of Platforms for a Specified VSAN
switch# show fcs platform vsan 1
Platform List for VSAN: 1
[Total 1 Platforms in Fabric]
Example 24-6 Displays a List of Switchports in a Specified VSAN
switch# show fcs port vsan 24
-- IE WWN: 20:18:00:05:30:00:16:df --
-------------------------------------------------------------------------
Port-WWN Type Module-Type Tx-Type
-------------------------------------------------------------------------
20:41:00:05:30:00:16:de TE_Port SFP with Serial Id Shortwave Laser
20:51:00:05:30:00:16:de TE_Port SFP with Serial Id Shortwave Laser
[Total 2 switch-ports in IE]
-- IE WWN: 20:18:00:05:30:00:20:df --
-------------------------------------------------------------------------
Port-WWN Type Module-Type Tx-Type
-------------------------------------------------------------------------
20:01:00:05:30:00:20:de TE_Port SFP with Serial Id Shortwave Laser
20:0a:00:05:30:00:20:de TE_Port SFP with Serial Id Shortwave Laser
[Total 2 switch-ports in IE]
Example 24-7 Displays Port Information for a Specified pWWN
switch# show fcs port pwwn 20:51:00:05:30:00:16:de vsan 24
Example 24-8 Displays FCS Statistics
switch# show fcs statistics
FCS Statistics for VSAN: 1
---------------------------
FCS Statistics for VSAN: 30
---------------------------
Example 24-9 Displays Platform Settings for Each VSAN
------------------------------
VSAN Plat Check fabric-wide
------------------------------