|
|
AIS |
Alarm Indication Signal |
AIS-L |
Alarm Indication Signal - Line |
AIS-P |
Alarm Indication Signal - Path |
AIS-V |
Alarm Indication Signal - VT |
ALS |
Automatic Laser Shutdown |
APC-DISABLED |
Automatic Power Control Disabled |
APC-FAIL |
Automatic Power Control Failure |
APSB |
Byte Failure |
APSC-IMP |
Improper APS Code |
APSCDFLTK |
Default K Byte |
APSCINCON |
Inconsistent APS Code |
APSCM |
Protection Switching Channel Match Failure |
APSCNMIS |
Node Id Mismatch |
APSIMP |
APS Invalid Mode |
APSMM |
Automatic Protection Switch Mode Mismatch |
AS-CMD |
Alarms Suppressed By User Command |
AS-MT |
Alarms Suppressed For Maintenance |
AU-LOF |
LOF - Administration Unit - Loss of Multi Frame |
AUD-LOG-LOSS |
Audit Log 100 Percent Full - Oldest records will be lost |
AUD-LOG-LOW |
Audit Log 80 Percent Full |
AUTOLSROFF |
Automatic Laser Shutoff Due To High Temperature |
AUTORESET |
Automatic System Reset |
AUTOSW-AIS |
Automatic Path Protection Switch Caused By AIS |
AUTOSW-LOP |
Automatic Path Protection Switch Caused By LOP |
AUTOSW-PDI |
Automatic Path Protection Switch Caused By PDI |
AUTOSW-SDBER |
Automatic Path Protection Switch Caused By SDBER |
AUTOSW-SFBER |
Automatic Path Protection Switch Caused By SFBER |
AUTOSW-UNEQ |
Automatic Path Protection Switch Caused By UNEQ |
BAT-FAIL |
Battery Failure |
BAT-HGH-VLT |
High Volt |
BAT-LOW-VLT |
Low Volt |
BKUPMEMP |
Primary Non-Volatile Backup Memory Failure |
BLSROSYNC |
BLSR Out Of Sync |
CARLOSS |
Carrier Loss On The LAN |
CKTDOWN |
Signaling Unable to setup circuit |
CLDRESTART |
Cold Restart |
COMIOXC |
IO Slot To XCON Communication Failure |
COMM-FAIL |
Plug-in Module Communication Failure |
CONTBUS-A-18 |
TCC A To DCC A Processor Communication Failure |
CONTBUS-B-18 |
TCC B To DCC B Processor Communication Failure |
CONTBUS_A |
Controller A To Shelf Slot Communication Failure |
CONTBUS_B |
Controller B To Shelf Slot Communication Failure |
CTNEQPT-MISMATCH |
Connection Equipment Mismatch |
CTNEQPT-PBPROT |
Interconnection Equipment Failure - Protect XC Payload Bus |
CTNEQPT-PBWORK |
Interconnection Equipment Failure - Working XC Payload Bus |
DATAFLT |
Software Fault - Data Integrity Fault |
DBOSYNC |
Standby Database Out of Sync |
DS3-MISM |
DS3 Frame Format Mismatch |
DSP-COMM-FAIL |
DSP Communication Failure |
DSP-FAIL |
DSP Failure |
DUP-IPADDR |
IP address already in use within the same DCC Area |
DUP-NODENAME |
Node name already in use within the same DCC Area |
E-W-MISMATCH |
Both Ends Of Fiber Provisioned As East Or Both As West |
EHIBATVG |
Extreme High Volt |
ELWBATVG |
Extreme Low Volt |
EOC |
SDCC Termination Failure |
EOC-L |
Line DCC Termination Failure |
EQPT |
Equipment Failure |
EQPT-MISS |
Replaceable Equipment/Unit is Missing |
ERFI-P-CONN |
Enhanced Remote Failure Indication - Path - Connectivity |
ERFI-P-PAYLD |
Enhanced Remote Failure Indication - Path - Payload |
ERFI-P-SRVR |
Enhanced Remote Failure Indication - Path - Server |
ERROR-CONFIG |
Error in Startup Config |
ETH-LINKLOSS |
Rear Panel Ethernet Link Removed |
EXCCOL |
Excess Collisions On The LAN |
EXERCISE-RING-FAIL |
Exercise Request on Ring Failed |
EXERCISE-RING-REQ |
Exercise Request on Ring |
EXERCISE-SPAN-FAIL |
Exercise Request on Span Failed |
EXERCISE-SPAN-REQ |
Exercise Request on Span |
EXT |
Failure Detected External To The NE |
EXTRA-TRAF-PREEMPT |
Extra Traffic Preempted |
FAILTOSW |
Failure To Switch To Protection |
FAILTOSW-PATH |
Failure To Switch To Protection - Path |
FAILTOSWR |
Failure To Switch To Protection - Ring |
FAILTOSWS |
Failure To Switch To Protection - Span |
FAN |
Fan Failure |
FANDEGRADE |
Partial Fan Failure |
FE-AIS |
Far End AIS |
FE-DS1-MULTLOS |
Far End Multiple DS1 LOS Detected On DS3 |
FE-DS1-NSA |
Far End DS1 Equipment Failure - Non Service Affecting |
FE-DS1-SA |
Far End DS1 Equipment Failure - Service Affecting |
FE-DS1-SNGLLOS |
Far End Single DS1 LOS |
FE-DS3-NSA |
Far End DS3 Equipment Failure - Non Service Affecting |
FE-DS3-SA |
Far End DS3 Equipment Failure - Service Affecting |
FE-EQPT-NSA |
Far End Common Equipment Failure - Non Service Affecting |
FE-EXERCISING-RING |
Far End Exercising Ring |
FE-EXERCISING-SPAN |
Far End Exercising Span |
FE-FRCDWKSWPR-RING |
Far End Working Facility Forced To Switch To Protection - Ring |
FE-FRCDWKSWPR-SPAN |
Far End Working Facility Forced To Switch To Protection - Span |
FE-IDLE |
Far End IDLE |
FE-LOCKOUTOFPR-SPAN |
Far End Lockout Of Protection - Span |
FE-LOF |
Far End LOF |
FE-LOS |
Far End LOS |
FE-MANWKSWPR-RING |
Far End Manual Switch Of Working Facility To Protection - Ring |
FE-MANWKSWPR-SPAN |
Far End Manual Switch Of Working Facility To Protection - Span |
FEC-MISM |
FEC Mismatch |
FEPRLF |
Far End Protection Line Failure |
FORCED-REQ |
Forced Switch Request |
FORCED-REQ-RING |
Forced Switch Request On Ring |
FORCED-REQ-SPAN |
Forced Switch Request On Span |
FRCDSWTOINT |
Forced Switch To Internal Clock |
FRCDSWTOPRI |
Forced Switch To Primary Reference |
FRCDSWTOSEC |
Forced Switch To Second Reference |
FRCDSWTOTHIRD |
Forced Switch To Third Reference |
FRNGSYNC |
Free Running Synchronization Mode |
FSTSYNC |
Fast Start Synchronization Mode |
FULLPASSTHR-BI |
Bidirectional Full Pass Through Is Active |
GCC-EOC |
GCC Termination Failure |
GE-OOSYNC |
GigaBit Ethernet Out of Sync |
HI-LASERBIAS |
Equipment High Laser Bias |
HI-RXPOWER |
Equipment High Rx power |
HI-TXPOWER |
Equipment High Tx power |
HITEMP |
High Temperature |
HLDOVRSYNC |
Holdover Synchronization Mode |
I-HITEMP |
Industrial High Temperature |
IMPROPRMVL |
Improper Removal |
INC-GFP-OUTOFFRAME |
Out Of Frame Detected by GFP Receiver |
INC-GFP-SIGLOSS |
Client Signal Loss Frames Detected by GFP Receiver |
INC-ISD |
DS3 Idle Condition |
INC-SIGLOSS |
Incoming Signal Loss on Fibre Channel Interface |
INC-SYNCLOSS |
Incoming Synchronization Loss on Fibre Channel Interface |
INC_GFP_SYNCLOSS |
Client Synchronization Loss Frames Detected by GFP Receiver |
INHSWPR |
Inhibit Switch To Protect Request On Equipment |
INHSWWKG |
Inhibit Switch To Working Request On Equipment |
INTRUSION-PSWD |
Security Intrusion Attempt Detected - See Audit Log |
INVMACADR |
Invalid MAC Address |
IOSCFGCOPY |
Ios Config Copy In Progress |
KB-PASSTHR |
K Bytes Pass Through Is Active |
KBYTE-APS-CHANNEL-FAILURE |
Kbyte Channel Failure |
LAN-POL-REV |
Lan Connection Polarity Reversed |
LASEREOL |
Laser Approaching End of Life |
LKOUTPR-S |
Lockout Of Protection - Span |
LMP-HELLODOWN |
LMP Hello FSM to Control Channel down |
LMP-NDFAIL |
LMP Neighbor Discovery has failed |
LO-RXPOWER |
Equipment Low Rx power |
LO-TXPOWER |
Equipment Low Tx power |
LOA |
Loss of Alignment |
LOC |
Loss of Channel |
LOCKOUT-REQ |
Lockout Switch Request On Facility or Equipment |
LOCKOUT-REQ-RING |
Lockout Switch Request On Ring |
LOF |
Loss Of Frame |
LOM |
Loss of Multi-Frame |
LOP-P |
Loss Of Pointer - Path |
LOP-V |
Loss Of Pointer - VT |
LOS |
Loss Of Signal |
LPBKCRS |
Cross-connect Loopback |
LPBKDS1FEAC |
DS1 Loopback Due To FEAC Command |
LPBKDS1FEAC-CMD |
DS1 Loopback Command Sent To Far End |
LPBKDS3FEAC |
DS3 Loopback Due To FEAC Command |
LPBKDS3FEAC-CMD |
DS3 Loopback Command Sent To Far End |
LPBKFACILITY |
Facility Loopback |
LPBKTERMINAL |
Terminal Loopback |
LWBATVG |
Low Volt |
MAN-REQ |
Manual Switch Request |
MANRESET |
Manual System Reset |
MANSWTOINT |
Manual Switch To Internal Clock |
MANSWTOPRI |
Manual Switch To Primary Reference |
MANSWTOSEC |
Manual Switch To Second Reference |
MANSWTOTHIRD |
Manual Switch To Third Reference |
MANUAL-REQ-RING |
Manual Switch Request On Ring |
MANUAL-REQ-SPAN |
Manual Switch Request On Span |
MEA |
Mismatch Of Equipment And Attributes |
MEM-GONE |
Free Memory On Card Near Zero |
MEM-LOW |
Free Memory On Card Very Low |
MFGMEM |
Manufacturing Data Memory (EEPROM Failure |
NO-CONFIG |
No Startup Config |
NTWTPINC |
Network Topology Incomplete |
OCHNC-ACTIV-FAIL |
Optical Channel Activation Failure |
OCHNC-DEACTIV-FAIL |
Optical Channel De-Activation Failure |
OCHNC-FAIL |
Optical Channel Connection Failure |
OCHNC-INC |
Optical Channel Incomplete |
ODUK-AIS-PM |
ODUk: Alarm Indication Signal |
ODUK-BDI-PM |
ODUk: PM Backward Defect Indication |
ODUK-LCK-PM |
ODUk: Locked Defect - PM |
ODUK-OCI-PM |
ODUk: Open Connection Indication |
ODUK-SD-PM |
ODUk: Signal Degrade |
ODUK-SF-PM |
ODUk: Signal Failure |
ODUK-TIM-PM |
ODUk: Trail Trace Identifier Mismatch |
OOU-TPT |
Out of Use - Transport Failure |
OPTNTWMIS |
Optical Network Type Mismatch |
OTUK-AIS |
OTUk: Alarm Indication Signal |
OTUK-BDI |
OTUk: Backward Defect Indication |
OTUK-LOF |
OTUk: Loss Of Frame |
OTUK-SD |
OTUk: Signal Degrade |
OTUK-SF |
OTUk: Signal Failure |
OTUK-TIM |
OTUk: Trail Trace Identifier Mismatch |
OUT-OF-SYNC |
8B10B Out of Sync |
PDI-P |
Payload Defect Indication - Path |
PEER-NORESPONSE |
Peer Card Not Responding |
PLM-P |
Payload Label Mismatch - Path |
PLM-V |
Signal Label Mismatch Failure - Payload Label Mismatch - VT |
PORT-CODE-MISM |
Pluggable Port security code mismatch |
PORT-COMM-FAIL |
Module Communication Failure |
PORT-MISMATCH |
Pluggable Port rate mismatch |
PORT-MISSING |
Pluggable Port missing |
PRC-DUPID |
Duplicate Node ID |
PROTNA |
Protection Unit Not Available |
PTIM |
Payload Type Identifier Mismatch |
PWR-REDUN |
Redundant Power Capability Lost |
RAI |
Remote Alarm Indication |
RCVR-MISS |
Facility Termination Equipment - Receiver Missing |
RFI |
Remote Failure Indication |
RFI-L |
Remote Failure Indication - Line |
RFI-P |
One-Bit Remote Failure Indication - Path |
RFI-V |
Remote Failure Indication - VT |
RING-ID-MIS |
Ring Id Mismatch |
RING-MISMATCH |
Far End Of Fiber Is Provisioned With Different Ring ID |
RING-SW-EAST |
Ring Switch Is Active On The East Side |
RING-SW-WEST |
Ring Switch Is Active On The West Side |
RSVP-HELLODOWN |
RSVP Hello FSM to Neighbor down |
RUNCFG-SAVENEED |
Need to Save Running Config |
SD |
Signal Degrade |
SD-L |
BER Threshold Exceeded For Signal Degrade - Line |
SD-P |
BER Threshold Exceeded For Signal Degrade - Path |
SF |
Signal Failure |
SF-L |
BER Threshold Exceeded For Signal Failure - Line |
SF-P |
BER Threshold Exceeded For Signal Failure - Path |
SFTWDOWN |
Software Download In Progress |
SNTP-HOST |
SNTP Host Failure |
SPAN-SW-EAST |
Span Switch Is Active On The East Side |
SPAN-SW-WEST |
Span Switch Is Active On The West Side |
SQM |
Sequence Mismatch |
SQUELCH |
Ring Is Squelching Traffic |
SQUELCHED |
Equipment Squelched |
SSM-DUS |
Do Not Use For Synchronization |
SSM-FAIL |
Failed To Receive Synchronization Status Message |
SSM-LNC |
G812 - Local Node Clock traceable |
SSM-OFF |
Synchronization Status Messages Are Disabled On This Interface |
SSM-PRC |
G811 - Primary Reference Clock traceable |
SSM-PRS |
Stratum 1 Primary Reference Source Traceable |
SSM-RES |
Reserved For Network Synchronization Use |
SSM-SDH-TN |
G812 - Transit Node Clock traceable |
SSM-SETS |
G813 - Synchronous Equipment Timing Source traceable |
SSM-SMC |
SONET Minimum Clock Traceable |
SSM-ST2 |
Stratum 2 Traceable |
SSM-ST3 |
Stratum 3 Traceable |
SSM-ST3E |
Stratum 3E Traceable |
SSM-ST4 |
Stratum 4 Traceable |
SSM-STU |
Synchronized - Traceability Unknown |
SSM-TNC |
Transit Node Clock Traceable |
SWMTXMOD |
Switching Matrix Module Failure |
SWTOPRI |
Switch To Primary Reference |
SWTOSEC |
Switch To Second Reference |
SWTOTHIRD |
Switch To Third Reference |
SYNC-FREQ |
Synchronization Reference Frequency Out Of Bounds |
SYNCPRI |
Primary Synchronization Reference Failure |
SYNCSEC |
Secondary Synchronization Reference Failure |
SYNCTHIRD |
Third Synchronization Reference Failure |
SYSBOOT |
System Reboot |
TIM |
TIM Section - Trace Identifier Mismatch Failure |
TIM-MON |
TIM Section Monitor - Trace Identifier Mismatch Failure |
TIM-P |
STS Path Trace Identifier Mismatch |
TPTFAIL |
Transport layer failure |
TRMT |
Transmit Failure |
TRMT-MISS |
Facility Termination Equipment - Transmitter Missing |
TUNDERRUN |
Ether tx underrun |
TX-AIS |
Alarm Indication Signal in TX |
TX-RAI |
Remote Alarm Indication in TX |
UNC-WORD |
FEC Uncorrected Word |
UNEQ-P |
Unequipped - Path |
UNEQ-V |
Signal Label Mismatch Failure - Unequipped VT |
VCG-DEG |
VCAT Group Degraded |
VCG-DOWN |
VCAT Group Down |
WKSWPR |
Switched To Protection |
WTR |
Wait To Restore |
WVL-MISMATCH |
Equipment Wavelength Mismatch |