- Index
- Preface
- Product Overview
- Command-line Interfaces
- Configuring the Switch for the First Time
- Administering the Switch
- Configuring the Cisco IOS In Service Software Upgrade Process
- Configuring Interfaces
- Checking Port Status and Connectivity
- Configuring Supervisor Engine Redundancy Using RPR and SSO
- Configuring Cisco NSF with SSO Supervisor Engine Redundancy
- Environmental Monitoring and Power Management
- Configuring Power over Ethernet
- Configuring Energy Wise
- Configuring the Catalyst 4500 Series Switch with Cisco Network Assistant
- Configuring VLANs, VTP, and VMPS
- Configuring IP Unnumbered Interface
- Configuring Layer 2 Ethernet Interfaces
- Configuring SmartPort Macros
- Auto SmartPort Macro
- Configuring STP and MST
- Configuring Flex Links and the MAC Address-Table Move Update Feature
- Configuring Resilient Ethernet Protocol
- Configuring Optional STP Features
- Configuring EtherChannels
- Configuring IGMP Snooping and Filtering
- Configuring IPv6 MLD Snooping
- Configuring 802.1Q and Layer 2 Protocol Tunneling
- Configuring CDP
- Configuring LLDP and LLDP-MED
- Configuring UDLD
- Configuring Unidirectional Ethernet
- Configuring Layer 3 Interfaces
- Configuring Cisco Express Forwarding
- Configuring Unicast Reverse Path Forwarding
- Configuring IP Multicast
- Configuring ANCP Client
- Configuring Policy-Based Routing
- Configuring VRF-lite
- Configuring Quality of Service
- Configuring Voice Interfaces
- Configuring Private VLANs
- Configuring 802.1X Port-Based Authentication
- Configuring PPPoE Intermediate Agent
- Configuring Web-Based Authentication
- Configuring Port Security
- Configuring Control Plane Policing
- Configuring DHCP Snooping, IP Source Guard, and IPSG for Static Hosts
- Configuring Dynamic ARP Inspection
- Configuring Network Security with ACLs
- IPv6
- Port Unicast and Multicast Flood Blocking
- Configuring Storm Control
- Configuring SPAN and RSPAN
- Configuring System Message Logging
- Configuring SNMP
- Configuring NetFlow
- Configuring Ethernet CFM and OAM
- Configuring Y.1731 (AIS and RDI)
- Configuring Call Home
- Configuring Cisco IOS IP SLAs Operations
- Configuring RMON
- Performing Diagnostics
- Configuring WCCP Version 2 Services
- ROM Monitor
- Configuring MIB Support
- Acronyms
- About Private VLANs
- Basic PVLAN Configuration Procedure
- Default Private VLAN Configuration
- PVLAN Configuration Guidelines and Restrictions
- Configuring a VLAN as a PVLAN
- Associating a Secondary VLAN with a Primary VLAN
- Configuring a Layer 2 Interface as a PVLAN Promiscuous Port
- Configuring a Layer 2 Interface as a PVLAN Host Port
- Configuring a Layer 2 Interface as an Isolated PVLAN Trunk Port
- Configuring a Layer 2 Interface as a Promiscuous PVLAN Trunk Port
- Permitting Routing of Secondary VLAN Ingress Traffic
Configuring Private VLANs
This chapter describes how to implement private VLANs (PVLANs) on Catalyst 4500 series switches.
This chapter includes the following major sections:
Note For complete syntax and usage information for the switch commands used in this chapter, see the Cisco Catalyst 4500 Series Switch Command Reference and related publications at this location:
http://www.cisco.com/en/US/products/hw/switches/ps4324/index.html
If the command is not found in the Cisco Catalyst 4500 Command Reference, you can locate it in the larger Cisco IOS library. Refer to the Cisco IOS Command Reference and related publications at this location:
http://www.cisco.com/en/US/products/ps6350/index.html
About Private VLANs
The private VLAN (PVLAN) feature addresses two problems that service providers face when using VLANs:
- The switch supports up to 1005 active VLANs. If a service provider assigns one VLAN per customer, this limits the numbers of customers the service provider can support.
- To enable IP routing, each VLAN is assigned a subnet address space or a block of addresses, which can result in wasting the unused IP addresses, and cause IP address management problems.
To configure PVLANs, you need to understand the concepts in these sections:
- PVLAN Overview
- PVLAN Terminology
- PVLANs Across Multiple Switches
- Private VLAN Interaction with Other Features
PVLAN Overview
Using PVLANs provides scalability and IP address management benefits for service providers and Layer 2 security for customers. PVLANs partition a regular VLAN domain into subdomains. A subdomain is represented by a pair of VLANs: a primary VLAN and a secondary VLAN. A PVLAN can have multiple VLAN pairs, one pair for each subdomain. All VLAN pairs in a PVLAN share the same primary VLAN. The secondary VLAN ID differentiates one subdomain from another. See Figure 39-1.
Figure 39-1 Private-VLAN Domain
The two types of secondary VLANs are as follows:
- Isolated VLANs—Ports within an isolated VLAN cannot communicate with each other at the Layer 2 level.
- Community VLANs—Ports within a community VLAN can communicate with each other but cannot communicate with ports in other communities at the Layer 2 level.
A promiscuous port can serve only one primary VLAN, one isolated VLAN, and multiple community VLANs. Layer 3 gateways are typically connected to the switch through a promiscuous port.
In a switched environment, you can assign an individual PVLAN and associated IP subnet to each individual or common group of end stations. The end stations need to communicate only with a default gateway to communicate outside the PVLAN.
You can use PVLANs to control access to end stations in these ways:
- Configure selected interfaces connected to end stations as isolated ports to prevent any communication at Layer 2. For example, if the end stations are servers, this configuration prevents Layer 2 communication between the servers.
- Configure interfaces connected to default gateways and selected end stations (such as backup servers) as promiscuous ports to allow all end stations access to a default gateway.
- Reduce VLAN and IP subnet consumption; you can prevent traffic between end stations even though they are in the same VLAN and IP subnet.
With a promiscuous port, you can connect a wide range of devices as access points to a PVLAN. For example, you can connect a promiscuous port to the server port of a LocalDirector to connect an isolated VLAN or a number of community VLANs to the server. LocalDirector can load balance the servers present in the isolated or community VLANs, or you can use a promiscuous port to monitor or back up all the PVLAN servers from an administration workstation.
PVLAN Terminology
The following table defines the key terms used in this chapter:
Standard Trunk Ports
As with regular VLANs, PVLANs can span multiple switches. A trunk port carries the primary VLAN and secondary VLANs to a neighboring switch. The trunk port relates to the PVLAN as any other VLAN. Traffic from an isolated port in one switch does not reach an isolated port on another switch. See Figure 39-2.
To maintain the security of your private VLAN configuration and to avoid other use of the VLANs configured as PVLANs, configure PVLANs on all intermediate devices, including devices that have no private VLAN ports.
Note Trunk ports carry traffic from regular VLANs and also from primary, isolated, and community VLANs.
Note Use standard trunk ports if both switches that use trunking support PVLANs.
Figure 39-2 PVLANs across Switches
Because VTP does not support PVLANs, you must manually configure PVLANs on all switches in the Layer 2 network. If you do not configure the primary and secondary VLAN association in some switches in the network, the Layer 2 databases in these switches are not merged. This situation can result in unnecessary flooding of private VLAN traffic on those switches.
Isolated PVLAN Trunk Ports
You use isolated PVLAN trunk ports if you anticipate using PVLAN isolated host ports to carry multiple VLANs, either normal VLANs or multiple PVLAN domains. You can connect a downstream switch that does not support PVLANs, such as a Catalyst 2950.
Figure 39-3 Isolated PVLAN Trunk Ports
In this illustration, a Catalyst 4500 switch connects to a downstream switch that does not support PVLANs.
Traffic being sent in the downstream direction towards host1 from the router is received by the
Catalyst 4500 series switch on the promiscuous port and in the primary VLAN (VLAN 10). The packets are then switched out of the isolated PVLAN trunk; instead of being tagged with the primary VLAN (VLAN 10) they are transmitted with the isolated VLAN’s tag (VLAN 11). When the packets arrive on the non-PVLAN switch, they can be bridged to the destination hosts’ access port.
Traffic in the upstream direction is sent by host1 to the non-PVLAN switch, arriving in VLAN 11. The packets are then transmitted to the Catalyst 4500 series switch tagged with that VLAN’s tag (VLAN 11) over the trunk port. On the Catalyst 4500 series switch, VLAN 11 is configured as the isolated VLAN, and the traffic is forwarded as if it came from an isolated host port.
Note The Catalyst 4500 series switch provides isolation between the isolated trunk and directly connected hosts (such as host3), but not between hosts connected to the non-PVLAN switch (such as host1 and host2). Isolation between these hosts must be provided by the non-PVLAN switch, using a feature such as protected ports on a Catalyst 2950.
For details on protected ports, see the URL:
http://www.cisco.com/en/US/docs/switches/lan/catalyst2950/software/release/12.1_22_ea11x/configuration/guide/swtrafc.html#wp1158863
Promiscuous PVLAN Trunk Ports
PVLAN promiscuous trunks are used in situations where a PVLAN promiscuous host port is normally used, but where it is necessary to carry multiple VLANs, either normal VLANs or multiple PVLAN domains. You can connect to an upstream router that does not support PVLANs, such as a Cisco 7200 router.
Figure 39-4 Promiscuous PVLAN Trunk Ports
In this illustration, a Catalyst 4500 series switch connects a PVLAN domain to an upstream router, which does not support PVLANs. Traffic being sent upstream by host1 arrives on the
Catalyst 4500 series switch in the community VLAN (VLAN 12). When this traffic is bridged onto the promiscuous PVLAN trunk towards the router, it is tagged with the primary VLAN (VLAN 10), so that it can be routed by using the correct subinterface configured on the router.
Traffic in the downstream direction is received on the promiscuous PVLAN trunk port by the
Catalyst 4500 series switch in the primary VLAN (VLAN 10), as if it had been received on a promiscuous host port. The traffic can then be bridged to the destination host as in any PVLAN domain.
PVLAN promiscuous trunks interact with VLAN QoS. Refer to the “PVLANs and VLAN ACL and QoS” section.
Private VLAN Interaction with Other Features
PVLANs have specific interaction with some other features, as described in these sections:
- PVLANs and VLAN ACL and QoS
- PVLANs and Unicast, Broadcast, and Multicast Traffic
- PVLANs and SVIs
- Per-Virtual Port Error-Disable on PVLANs
For details, see the section “PVLAN Configuration Guidelines and Restrictions” section.
PVLANs and VLAN ACL and QoS
PVLAN ports use primary and secondary VLANs, as follows:
- A packet received on a PVLAN host port belongs to the secondary VLAN.
- A packet received on a PVLAN trunk port belongs to the secondary VLAN if the packet is tagged with a secondary VLAN or if the packet is untagged and the native VLAN on the port is a secondary VLAN.
A packet received on a PVLAN host or trunk port and assigned to a secondary VLAN is bridged on the secondary VLAN. Because of this bridging, the secondary VLAN ACL as well as the secondary VLAN QoS (on input direction) apply.
When a packet is transmitted out of a PVLAN host or trunk port, the packet logically belongs to the primary VLAN. This relationship applies even though the packet may be transmitted with the secondary VLAN tagging for PVLAN trunk ports. In this situation, the primary VLAN ACL and the primary VLAN QoS on output apply to the packet.
- Similarly, a packet received on a PVLAN promiscuous access port belongs to primary VLAN.
- A packet received on a PVLAN promiscuous trunk port could belong to the primary VLAN or normal VLAN depending on incoming VLAN.
For traffic flowing in normal VLAN on promiscuous trunk ports, normal VLAN ACL and QoS policies apply. For traffic flowing in a PVLAN domain, a packet received on a promiscuous port is bridged in primary VLAN. The primary VLAN ACL and QoS policies apply on input.
When a packet is transmitted out of a promiscuous trunk port, the packet could logically belong to secondary VLAN if received from a secondary port, or in primary VLAN if bridged from another promiscuous port. Because we cannot differentiate between both packets, all VLAN QoS policies are ignored on packets egressing promiscuous trunk ports.
PVLANs and Unicast, Broadcast, and Multicast Traffic
In regular VLANs, devices in the same VLAN can communicate with each other at the Layer 2 level, but devices connected to interfaces in different VLANs must communicate at the Layer 3 level. In PVLANs, the promiscuous ports are members of the primary VLAN, while the host ports belong to secondary VLANs. Because the secondary VLAN is associated to the primary VLAN, members of the these VLANs can communicate with each other at the Layer 2 level.
In a regular VLAN, broadcasts are forwarded to all ports in that VLAN. PVLAN broadcast forwarding depends on the port sending the broadcast:
- An isolated port sends a broadcast only to the promiscuous ports or trunk ports.
- A community port sends a broadcast to all promiscuous ports, trunk ports, and ports in the same community VLAN.
- A promiscuous port sends a broadcast to all ports in the PVLAN (other promiscuous ports, trunk ports, isolated ports, and community ports).
Multicast traffic is routed or bridged across private VLAN boundaries and within a single community VLAN. Multicast traffic is not forwarded between ports in the same isolated VLAN or between ports in different secondary VLANs.
PVLANs and SVIs
In a Layer 3 switch, a switch virtual interface (SVI) represents the Layer 3 interface of a VLAN. Layer 3 devices communicate with a PVLAN only using the primary VLAN and not through secondary VLANs. Configure Layer 3 VLAN interfaces (SVIs) only for primary VLANs. You cannot configure Layer 3 VLAN interfaces for secondary VLANs. SVIs for secondary VLANs are inactive while the VLAN is configured as a secondary VLAN.
- If you try to configure a VLAN with an active SVI as a secondary VLAN, the configuration is not allowed until you disable the SVI.
- If you try to create an SVI on a VLAN that is configured as a secondary VLAN and the secondary VLAN is already mapped at Layer 3, the SVI is not created, and an error is returned. If the SVI is not mapped at Layer 3, the SVI is created, but it is automatically shut down.
When the primary VLAN is associated with and mapped to the secondary VLAN, any configuration on the primary VLAN is propagated to the secondary VLAN SVIs. For example, if you assign an IP subnet to the primary VLAN SVI, this subnet is the IP subnet address of the entire PVLAN.
Per-Virtual Port Error-Disable on PVLANs
For PVLANs, per-virtual port error-disable behavior is defined as follows:
- On a PVLAN promiscuous or promiscuous trunk ports, if a violation occurs on the primary VLAN, it is error-disabled.
- On a PVLAN host or trunk port, if a violation occurs on the secondary VLAN, the associated primary VLAN is error-disabled.
- On a standard trunk port that carries both primary and secondary VLANs, if a violation occurs on the primary VLAN, this VLAN and all its associated secondary VLANs are error-disabled. If a violation occurs on a secondary VLAN, the associated primary VLAN and all its associated secondary VLANs are error-disabled.
PVLAN Commands
This table lists the commands most commonly used with PVLANs.
private-vlan association { secondary_vlan_list | add secondary_vlan_list | remove secondary_vlan_list } |
Associates the secondary VLAN with the primary VLAN. The list can contain only one isolated VLAN ID; it can also contain multiple community VLAN IDs. |
|
switchport mode private-vlan { host | promiscuous | trunk promiscuous | trunk [secondary] } |
||
switchport private-vlan mapping [ trunk] primary_vlan_ID { secondary_vlan_list | add secondary_vlan_list | remove secondary_vlan_list } |
Maps the PVLAN promiscuous port to a primary VLAN and to selected secondary VLANs. |
Configuring a Layer 2 Interface as a PVLAN Promiscuous Port Configuring a Layer 2 Interface as a Promiscuous PVLAN Trunk Port |
Switch(config-if)# switchport private-vlan host-association primary_vlan_ID secondary_vlan_ID |
Associates the Layer 2 interface with a PVLAN. Note You can associate only one primary-secondary VLAN pair to the isolated port. |
|
switchport private-vlan association trunk primary_vlan_ID secondary_vlan_ID |
Configures association between primary VLANs and secondary VLANs the PVLAN trunk port with a PVLAN. Note You can configure the isolated trunk port with multiple primary-secondary pair. |
Configuring a Layer 2 Interface as an Isolated PVLAN Trunk Port |
switchport private-vlan trunk allowed vlan vlan_list all | none | [ add | remove | except ] vlan_atom [, vlan_atom ...] |
Configures a list of allowed normal VLANs on a PVLAN trunk port. |
Configuring a Layer 2 Interface as an Isolated PVLAN Trunk Port |
Configures a VLAN to which untagged packets (as in IEEE 802.1Q tagging) are assigned on a PVLAN trunk port. |
Configuring a Layer 2 Interface as an Isolated PVLAN Trunk Port |
Configuring PVLANs
These sections describe how to configure PVLANs:
- Basic PVLAN Configuration Procedure
- Default Private VLAN Configuration
- PVLAN Configuration Guidelines and Restrictions
- Configuring a VLAN as a PVLAN
- Associating a Secondary VLAN with a Primary VLAN
- Configuring a Layer 2 Interface as a PVLAN Promiscuous Port
- Configuring a Layer 2 Interface as a PVLAN Host Port
- Configuring a Layer 2 Interface as an Isolated PVLAN Trunk Port
- Configuring a Layer 2 Interface as a Promiscuous PVLAN Trunk Port
- Permitting Routing of Secondary VLAN Ingress Traffic
Basic PVLAN Configuration Procedure
To configure a PVLAN, follow these basic steps:
Step 1 Set VTP mode to transparent. See the “VLAN Trunking Protocol” section.
Step 2 Create the secondary VLANs. See the “Configuring a VLAN as a PVLAN” section.
Step 3 Create the primary VLAN. See the “Configuring a VLAN as a PVLAN” section.
Step 4 Associate the secondary VLAN to the primary VLAN. See the “Associating a Secondary VLAN with a Primary VLAN” section.
Note Only one isolated VLAN can be mapped to a primary VLAN, but more than one community VLAN can be mapped to a primary VLAN.
Step 5 Configure an interface as an isolated or community host or trunk port. See the “Configuring a Layer 2 Interface as a PVLAN Host Port” section and “Configuring a Layer 2 Interface as an Isolated PVLAN Trunk Port” section.
Step 6 Associate the isolated port or community port to the primary-secondary VLAN pair. See the “Associating a Secondary VLAN with a Primary VLAN” section.
Step 7 Configure an interface as a promiscuous port. See the “Configuring a Layer 2 Interface as a PVLAN Promiscuous Port” section.
Step 8 Map the promiscuous port to the primary-secondary VLAN pair. See the “Configuring a Layer 2 Interface as a PVLAN Promiscuous Port” section.
Step 9 If you plan to use inter-VLAN routing, configure the primary SVI, and map secondary VLANs to the primary. See the “Permitting Routing of Secondary VLAN Ingress Traffic” section.
Step 10 Verify private VLAN configuration.
PVLAN Configuration Guidelines and Restrictions
When using or configuring PVLANs, consider these guidelines and restrictions:
-
To configure a PVLAN correctly, enable VTP in transparent mode in VTP version 1 and
VTP version 2. (VTP version 3 enables you to create it in server mode).
You cannot change the VTP mode to client or server for PVLANs.
- Do not include VLAN 1 or VLANs 1002 through 1005 in PVLANs.
- Use only PVLAN commands to assign ports to primary, isolated, or community VLANs.
Layer 2 interfaces on primary, isolated, or community VLANs are inactive in PVLANs. Layer 2 trunk interfaces remain in the STP forwarding state.
Layer 3 VLAN interfaces for isolated and community (secondary) VLANs are inactive while the VLAN is configured as an isolated or community VLAN.
- Do not configure PVLAN ports as EtherChannels. While a port is part of the PVLAN configuration, its associated EtherChannel configuration is inactive.
- Do not apply dynamic access control entries (ACEs) to primary VLANs.
Cisco IOS dynamic ACL configuration applied to a primary VLAN is inactive while the VLAN is part of the PVLAN configuration.
- To prevent spanning tree loops due to misconfigurations, enable PortFast on the PVLAN trunk ports with the spanning-tree portfast trunk command.
- Any VLAN ACL configured on a secondary VLAN is effective in the input direction, and any VLAN ACL configured on the primary VLAN associated with the secondary VLAN is effective in the output direction.
- You can stop Layer 3 switching on an isolated or community VLAN by deleting the mapping of that VLAN with its primary VLAN.
- PVLAN ports can be on different network devices as long as the devices are trunk-connected and the primary and secondary VLANs remain associated with the trunk
- Isolated ports on two different devices cannot communicate with each other, but community VLAN ports can.
- PVLANs support the following SPAN features:
– You can configure a PVLAN port as a SPAN source port.
– You can use VLAN-based SPAN (VSPAN) on primary, isolated, and community VLANs or use SPAN on only one VLAN to monitor egress or ingress traffic separately.
For more information about SPAN, see Chapter51, “Configuring SPAN and RSPAN”
- A primary VLAN can be associated with multiple community VLANs, but only one isolated VLAN.
- An isolated or community VLAN can be associated with only one primary VLAN.
- If you delete a VLAN used in a PVLAN configuration, the PVLAN ports associated with the VLAN become inactive.
- VTP does not support PVLANs. You must configure PVLANs on each device in which you plan to use PVLAN ports.
- To maintain the security of your PVLAN configuration and avoid other use of VLANs configured as PVLANs, configure PVLANs on all intermediate devices, even if the devices have no PVLAN ports.
- Prune the PVLANs from trunks on devices that carry no traffic in the PVLANs.
- With port ACLS functionality available, you can apply Cisco IOS ACLS to secondary VLAN ports and Cisco IOS ACLS to PVLANS (VACLs). For more information on VACLs, see Chapter47, “Configuring Network Security with ACLs”
- You can apply different quality of service (QoS) configurations to primary, isolated, and community VLANs. See Chapter37, “Configuring Quality of Service” Cisco IOS ACLs applied to the Layer 3 VLAN interface of a primary VLAN automatically apply to the associated isolated and community VLANs.
- On a PVLAN trunk port a secondary VLAN ACL is applied on ingress traffic and a primary VLAN ACL is applied on egress traffic.
- On a promiscuous port the primary VLAN ACL is applied on ingress traffic.
- Both PVLAN secondary and promiscuous trunk ports support only IEEE 802.1q encapsulation.
- Community VLANs cannot be propagated or carried over PVLAN trunks.
- ARP entries learned on Layer 3 PVLAN interfaces are termed “sticky” ARP entries (we recommend that you display and verify PVLAN interface ARP entries).
- For security reasons, PVLAN port sticky ARP entries do not age out. Connecting a device with a different MAC address but with the same IP address generates an error message and the ARP entry is not created.
- Because PVLAN port sticky ARP entries do not age out, you must manually remove the entries if you change the MAC address. To overwrite a sticky ARP entry, first delete the entry with the no arp command, then overwrite the entry with the arp command.
- In a DHCP environment, if you shut down your PC, it is not possible to give your IP address to someone else. To solve this problem, the Catalyst 4500 series switch supports the no ip sticky-arp command. This command promotes IP address overwriting and reuse in a DHCP environment.
- Normal VLANs can be carried on a promiscuous or isolated trunk port.
- The default native VLAN for promiscuous trunk port is VLAN 1, the management VLAN. All untagged packets are forwarded in the native VLAN. Either the primary VLANs or a regular VLAN can be configured as native VLAN.
- Promiscuous trunks cannot be configured to carry secondary VLANs. If a secondary VLAN is specified in the allowed VLAN list, the configuration is accepted but the port is not operational in the secondary VLAN (including even those VLANs that are secondary but not associated with any primary VLAN on given port).
- On a promiscuous trunk port, the primary VLAN ACL and QoS are applied on ingress traffic arriving in primary VLANs.
- On a promiscuous trunk port, no VLAN ACL or QoS is applied to the egress traffic because for upstream direction, traffic in the PVLAN logically flows in the secondary VLAN. Due to VLAN translation in hardware, information about received secondary VLANs has been lost, and no policies are applied. This restriction also applies to traffic bridged from other ports in the same primary VLANs.
- Do not configure port security on a PVLAN promiscuous trunk port.
If port security is enabled on a promiscuous trunk port, that port may operate in an unpredictable manner because this functionality is not supported.
Note Community PVLAN trunk ports are not supported.
Configuring a VLAN as a PVLAN
To configure a VLAN as a PVLAN, perform this task:
This example shows how to configure VLAN 202 as a primary VLAN and verify the configuration:
This example shows how to configure VLAN 303 as a community VLAN and verify the configuration:
This example shows how to configure VLAN 440 as an isolated VLAN and verify the configuration:
Associating a Secondary VLAN with a Primary VLAN
To associate secondary VLANs with a primary VLAN, perform this task:
When you associate secondary VLANs with a primary VLAN, note the following:
- The secondary_vlan_list parameter cannot contain spaces. It can contain multiple comma-separated items. Each item can be a single PVLAN ID or a hyphenated range of PVLAN IDs.
- The secondary_vlan_list parameter can contain multiple community VLAN IDs.
- The secondary_vlan_list parameter can contain only one isolated VLAN ID.
- Enter a secondary_vlan_list or use the add keyword with a secondary_vlan_list to associate secondary VLANs with a primary VLAN.
- Use the remove keyword with a secondary_vlan_list to clear the association between secondary VLANs and a primary VLAN.
- The command does not take effect until you exit VLAN configuration submode.
This example shows how to associate community VLANs 303 through 307 and 309 and isolated VLAN 440 with primary VLAN 202 and verify the configuration:
Note The secondary VLAN 308 has no associated primary VLAN.
Configuring a Layer 2 Interface as a PVLAN Promiscuous Port
To configure a Layer 2 interface as a PVLAN promiscuous port, perform this task:
Note The maximum number of unique PVLAN pairs supported by the switchport private-vlan mapping command is 1000.
When you configure a Layer 2 interface as a PVLAN promiscuous port, note the following:
- The secondary_vlan_list parameter cannot contain spaces. It can contain multiple comma-separated items. Each item can be a single PVLAN ID or a hyphenated range of PVLAN IDs.
- Enter a secondary_vlan_list or use the add keyword with a secondary_vlan_list to map the secondary VLANs to the PVLAN promiscuous port.
- Use the remove keyword with a secondary_vlan_list to clear the mapping between secondary VLANs and the PVLAN promiscuous port.
This example shows how to configure interface FastEthernet 5/2 as a PVLAN promiscuous port, map it to a PVLAN, and verify the configuration:
Configuring a Layer 2 Interface as a PVLAN Host Port
To configure a Layer 2 interface as a PVLAN host port, perform this task:
Associates the Layer 2 interface with a PVLAN. You can use the no keyword to delete all associations from the primary VLAN. |
||
This example shows how to configure interface FastEthernet 5/1 as a PVLAN host port and verify the configuration:
Configuring a Layer 2 Interface as an Isolated PVLAN Trunk Port
To configure a Layer 2 interface as an isolated PVLAN trunk port, perform this task:
This example shows how to configure interface FastEthernet 5/2 as a secondary trunk port, and verify the configuration:
Configuring a Layer 2 Interface as a Promiscuous PVLAN Trunk Port
To configure a Layer 2 interface as a promiscuous PVLAN trunk port, perform this task:
Note The maximum number of unique PVLAN pairs supported by the
switchport private-vlan mapping trunk command is 500. For example, 500 isolated secondary VLANs can map to 500 primary VLANs because only one isolated VLAN association per primary VLAN is supported. 500 community secondary VLANs also can map to one primary VLAN. 250 community secondary VLANs can map to 1 primary VLAN, and another 250 community secondary VLANs can map to another primary VLAN for a total of 500 pairs.
Note By default, if you configure the mode to PVLAN trunk promiscuous, the native VLAN is set to 1.
The [no] switchport private-vlan mapping command provides the following three levels of removal:
- Removes the entire mapping of PVLAN promiscuous trunk port to the specified primary VLAN (and all of its selected secondary VLANs). For example:
- Removes the mapping of a PVLAN promiscuous trunk port to all previously configured primary VLANs (and all of their selected secondary VLANs). For example:
When you configure a Layer 2 interface as a PVLAN promiscuous port, note the following:
- Multiple PVLAN pairs can be specified using the switchport private-vlan mapping trunk command so that a promiscuous trunk port can carry multiple primary VLANs.
- The secondary_vlan_list parameter cannot contain spaces. It can contain multiple comma-separated items. Each item can be a single PVLAN ID or a hyphenated range of PVLAN IDs.
- Enter a secondary_vlan_list or use the add keyword with a secondary_vlan_list to map the secondary VLANs to the PVLAN promiscuous port.
- Use the remove keyword with a secondary_vlan_list to clear the mapping between secondary VLANs and the PVLAN promiscuous port.
This example shows how to configure interface FastEthernet 5/2 as a promiscuous trunk port and to verify the configuration:
Permitting Routing of Secondary VLAN Ingress Traffic
Note Isolated and community VLANs are both called secondary VLANs.
To permit routing of secondary VLAN ingress traffic, perform this task:
To permit routing on the secondary VLAN ingress traffic, map the secondary VLAN to the primary VLAN. You can use the no keyword to delete all associations from the primary VLAN. |
||
When you permit routing on the secondary VLAN ingress traffic, note the following:
- The private-vlan mapping interface configuration command only affects PVLAN ingress traffic that is Layer 3 switched.
- The secondary_vlan_list parameter cannot contain spaces. It can contain multiple comma-separated items. Each item can be a single PVLAN ID or a hyphenated range of PVLAN IDs.
- Enter a secondary_vlan_list parameter or use the add keyword with a secondary_vlan_list parameter to map the secondary VLANs to the primary VLAN.
- Use the remove keyword with a secondary_vlan_list parameter to clear the mapping between secondary VLANs and the primary VLAN.
This example shows how to permit routing of secondary VLAN ingress traffic from PVLANs 303 through 307, 309, and 440 and verify the configuration: