Technical Specifications

Technical Specifications

This table describes the environmental specifications.

Table 1. Environmental Specifications for the Switch

Environmental Ranges

Operating temperature

  • 32°F to 104°F (0 to 40°C) for 9500X switches with C9500X-FAN-1U-R1 fans

  • -41°F to 95°F (-5°C to 35°C) for 9500X switches with C9500X-FAN-1U-F2 fans

Storage temperature

  • -40°F to 158° F (-40°C to 70°C)

Relative humidity

  • Operating : 5 to 90% (noncondensing)

  • Non-Operating : 5% to 95% (noncondensing)

Operating altitude

Up to 6000 ft (1800 m)

Storage altitude

Up to 15,000 ft (4500 m)

1 Front-to-back airflow
2 Back-to-front airflow
Table 2. Acoustic Measurements for the Switches

Switch Model

Sound Power Level

C9500X-28C8D with C9500X-FAN-1U-R3

No greater than 68.7 LWAd dB

C9500X-28C8D with C9500X-FAN-1U-F4

No greater than 69.9 LWAd dB

C9500X-60L4D with C9500X-FAN-1U-R5

No greater than 74.1 LWAd dB

C9500X-60L4D with C9500X-FAN-1U-F6

No greater than 78 LWAd dB

3 Front-to-back airflow
4 Back-to-front airflow
5 Front-to-back airflow
6 Back-to-front airflow

This table describes the physical specifications.

Table 3. Physical Specifications for the Switch

Physical Specifications

Dimensions (H x W x D)

1.73 x 17.5 x 21.8 in. (4.4 x 44.5 x 55.4 cm)

C9500X-28C8D

1.73 x 17.5 x 21.8 in. (4.4 x 44.5 x 55.4 cm)

C9500X-60L4D

Rack units (RU)

1 RU

Chassis with 2 power supplies and built-in fan

29.27 lbs (13.28 kg)

C9500X-28C8D

28.0428 lbs (12.72 kg)

C9500X-60L4D

This table describes the power requirements.

Table 4. Power Requirements

Power Requirements

Input Voltage

90 to 264 VAC

C9500X-60L4D

C9500X-28C8D

For power supply specifications, refer the Cisco Catalyst 9500 Series Switches Data Sheet.

AC Power Cord Specifications

The following table lists the specifications for the AC power cords that are available for the AC-input power supplies. The table also includes references to power cord illustrations.


Note


  • The power cords for C9500X have an IEC60320/C21 appliance connector at one end.

    Figure 1. IEC60320/C21 Appliance Connector



Table 5. AC Power Cords for C9500X Series Switches

Locale

Part Number

Cordset Rating

Length

Plug Type

United States of America

PWR-CAB-AC-USA520

125 VAC, 20 A

4.25 m

Figure 2. PWR-CAB-AC-USA520= (United States of America)


United States of America

PWR-CAB-AC-USA

250 VAC, 20 A

4.25 m

Figure 3. PWR-CAB-AC-USA= (United States of America)


Australia

PWR-CAB-AC-AUS

250 VAC, 15 A

4.25 m

Figure 4. PWR-CAB-AC-AUS= (Australia)


Europe

PWR-CAB-AC-EU

250 VAC, 16 A

4.25 m

Figure 5. PWR-CAB-AC-EU= (Europe)


Italy

PWR-CAB-AC-ITA

250 VAC, 16 A

4.25 m

Figure 6. PWR-CAB-AC-ITA (Italy)


South Africa

PWR-CAB-AC-SA

250 VAC, 16 A

4.25 m

Figure 7. PWR-CAB-AC-SA= (South Africa)


United Kingdom

PWR-CAB-AC-UK

250 VAC, 16 A

4.25 m

Figure 8. PWR-CAB-AC-UK= (United Kingdom)


Israel

PWR-CAB-AC-ISRL

250 VAC, 16 A

4.25 m

Figure 9. PWR-CAB-AC-ISRL= (Israel)


China

PWR-CAB-AC-CHN

250 VAC, 16 A

4.25 m

Figure 10. PWR-CAB-AC-CHN= (China)


Brazil

PWR-CAB-AC-BRA

250 VAC, 16 A

4.25 m

Figure 11. PWR-CAB-AC-BRA= (Brazil)


Switzerland

PWR-CAB-AC-SUI

250 VAC, 16 A

4.25 m

Figure 12. PWR-CAB-AC-SUI= (Switzerland)


Japan

PWR-CAB-AC-JPN

250 VAC, 20 A

4.25 m

Figure 13. CAB-TA-250V-JP= (Japan)


India

PWR-CAB-AC-IND

250 VAC, 16 A

4.25 m

Figure 14. PWR-CAB-AC-IND= (India)


Argentina

PWR-CAB-AC-ARG

250 VAC, 16 A

4.25 m

Figure 15. PWR-CAB-AC-ARG= (Argentina)

DC Power Cable Specifications

Figure 16. PWR-2KW-DC-CBL