- About this Manual
- Chapter 1, Shelf and Backplane Hardware
- Chapter 2, Card Reference
- Chapter 3, Card Protection
- Chapter 4, Cisco Transport Controller Operation
- Chapter 5, Security
- Chapter 6, Timing
- Chapter 7, Circuits and Tunnels
- Chapter 8, SDH Topologies and Upgrades
- Chapter 9, Management Network Connectivity
- Chapter 10, Ethernet Operation
- Chapter 11, Alarm Monitoring and Management
- Chapter 12, Performance Monitoring
- Chapter 13, SNMP
- Appendix A, Hardware Specifications
- Appendix B, Administrative and Service States
- Appendix C, Network Element Defaults
- A.1 Shelf Specifications
- A.1.1 Bandwidth
- A.1.2 Slot Assignments
- A.1.3 Cards
- A.1.4 Configurations
- A.1.5 Dimensions
- A.1.6 Cisco Transport Controller
- A.1.7 External LAN Interface
- A.1.8 TL1 Craft Interface
- A.1.9 Modem Interface
- A.1.10 Alarm Interface
- A.1.11 BITS Interface
- A.1.12 System Timing
- A.1.13 Database Storage
- A.1.14 Environmental Specifications
- A.1.15 Power Specifications
- A.2 Card Specifications
- A.2.1 TSC Card Specifications
- A.2.2 SSXC Specifications
- A.2.3 OC48/STM16 LR/LH 16 Port 1550 Specifications
- A.2.4 OC48/STM16 SR/SH 16 Port 1310 Specifications
- A.2.5 OC192/STM64 LR/LH 4 Port 1550 Specifications
- A.2.6 OC192/STM64 SR/SH 4 Port 1310 Specifications
- A.2.7 ASAP Specifications
- A.2.8 Filler Card Specifications
- A.3 SFP/XFP Specifications
Hardware Specifications
This appendix provides detailed shelf assembly hardware specifications for the Cisco ONS 15600 SDH. It includes the following sections:
A.1 Shelf Specifications
This section provides bandwidth specifications; slot assignments; lists of cards and topologies; shelf dimensions; Cisco Transport Controller (CTC) specifications; the LAN, TL1, modem, and alarm interface specifications; and timing, database, environmental, and power specifications.
A.1.1 Bandwidth
The ONS 15600 SDH has the following bandwidth specifications:
•Total bandwidth: 320 Gbps
•Optical bandwidth: 40 Gbps per slot
A.1.2 Slot Assignments
The ONS 15600 SDH has the following slot assignments:
•Total card slots: 14
•Optical cards: Slots 1 to 4, 11 to 14
•TSC: Slots 5, 10
•SSXC: Slots 6/7, 8/9
A.1.3 Cards
The ONS 15600 SDH has the following cards:
•TSC
•SSXC
•ASAP
•OC48/STM16 LR16 1550
•OC48/STM16 SR16 1310
•OC192/STM64 LR4 1550
•OC192/STM64 SR4 1310
•OC192/STM64 4 Port ITU C-Band
A.1.4 Configurations
The ONS 15600 SDH has the following configurations:
•1+1 automatic protections switching (APS) for point-to-point and linear configurations
•Two-fiber subnetwork connection protection ring (SNCP)
•Path-protected mesh network (PPMN)
•Two-fiber multiplex section-shared protection ring (MS-SPRing)
•Four-fiber multiplex section-shared protection ring (MS-SPRing)
•Unprotected
A.1.5 Dimensions
The ONS 15600 SDH has the following dimensions:
•Height: 83.9 inches (2130 mm)
•Width: 23.6 inches (600 mm)
•Depth: 23.6 inches (600 mm)
•Weight: 500 lb (226.8 kg) (without cards)
A.1.6 Cisco Transport Controller
CTC has the following specifications:
•10/100BaseT
•TSC access: RJ-45 connector
•Backplane access: RJ-45 connector
A.1.7 External LAN Interface
The external LAN interface has the following specifications:
•10/100BaseT Ethernet
•Backplane access: RJ-45 connector
A.1.8 TL1 Craft Interface
The TL1 craft interface has the following specifications:
•Speed: 9600 bps
•Backplane (CAP/CAP2) access: EIA/TIA-232 DB-9 type connector
A.1.9 Modem Interface
The modem interface has the following specifications:
•Hardware flow control
•Backplane (CAP/CAP2) access: EIA/TIA-232 DB-9 type connector
A.1.10 Alarm Interface
The alarm interface has the following specifications:
•Visual: Critical, Major, Minor, Remote
•Audible: Critical, Major, Minor, Remote
•Alarm contacts: 0.045 mm, -48 VDC, 50 mA
•Backplane (CAP/CAP2) access: Alarm pin fields
A.1.11 BITS Interface
The building integrated timing supply (BITS) interface has the following specifications:
•2 DS-1 BITS inputs
•2 derived STM-N outputs
A.1.12 System Timing
The ONS 15600 SDH has the following system timing specifications:
•Holdover stability: Stratum 3E per Telcordia GR-253-CORE
•Free running accuracy: +/- 4.6 ppm
•Reference: External BITS, line, internal
A.1.13 Database Storage
The ONS 15600 SDH has the following database storage specifications:
•Nonvolatile memory: 512 MB, IDE FLASH memory
A.1.14 Environmental Specifications
The ONS 15600 SDH has the following environmental specifications:
•Operating temperature: 23 to 122 degrees Fahrenheit (-5 to +50 degrees Celsius)
•Operating humidity: 5 to 95 percent, noncondensing
A.1.15 Power Specifications
The ONS 15600 SDH has the following power specifications:
•Input voltage: -48 VDC
•Input current: 80 A per channel (six channels provided)
•Power terminals: Lug
Table A-1 lists the power requirements for each card.
Table A-2 lists the power requirements for an individual fan in the fan-tray assembly.
A.2 Card Specifications
This section provides specifications for the following cards:
•TSC
•SSXC
•OC48/STM16 LR/LH 16 Port 1550
•OC48/STM16 SR/SH 16 Port 1310
•OC192/STM64 LR/LH 4 Port 1550
•OC192/STM64 SR/SH 4 Port 1310
•OC192/STM64 4 Port ITU C-BandASAP
•Filler
A.2.1 TSC Card Specifications
Table A-3 shows the TSC card specifications.
A.2.2 SSXC Specifications
Table A-4 shows the SSXC card specifications.
A.2.3 OC48/STM16 LR/LH 16 Port 1550 Specifications
Table A-5 shows the OC48/STM16 LR/LH 16 Port 1550 card specifications.
A.2.4 OC48/STM16 SR/SH 16 Port 1310 Specifications
Table A-6 shows the OC48/STM16 SR/SH 16 Port 1310 card specifications.
A.2.5 OC192/STM64 LR/LH 4 Port 1550 Specifications
Table A-7 shows the OC192/STM64 LR/LH 4 Port 1550 card specifications.
A.2.6 OC192/STM64 SR/SH 4 Port 1310 Specifications
Table A-8 shows the OC192/STM64 SR/SH 4 Port 1310 card specifications.
A.2.7 ASAP Specifications
Table A-9 shows the ASAP card specifications.
A.2.8 Filler Card Specifications
Table A-10 shows the Filler card specifications.
|
|
---|---|
Dimensions |
Height: 16.50 in. (419 mm) Width:1.50 in. (38 mm) Depth: 18.31 in. (465 mm) Card weight: 2.5 lb (1.134 kg) |
A.3 SFP/XFP Specifications
Table A-11 and Table A-12 list the specifications for Cisco ONS 15600 SDH SFPs and XFPs.
The OC-48/STM16 also supports 32-channel SFPs for DWDM applications; 32-channel SFPs can be plugged into the four-port ASAP card 4PIO module.
Some of the parameters common across all 32 DWDM SFPs include:
•Receiver wavelength: 1260 to 1620 nm
•Minimum overload: -9 dBm
•Maximum reflectance of receiver, measured at Rupees: -27 dB
•Maximum receiver power, damage threshold: +5 dBm
•Transmitter output power min/max : 0 to +4 dBm
Table A-13 lists the available DWDM SFPs.
|
|
|
---|---|---|
ONS-SC-2G-30.3 |
OC-48/STM16 |
1530.3 nm |
ONS-SC-2G-31.1 |
OC-48/STM16 |
1531.1 nm |
ONS-SC-2G-31.9 |
OC-48/STM16 |
1531.9 nm |
ONS-SC-2G-32.6 |
OC-48/STM16 |
1532.6 nm |
ONS-SC-2G-34.2 |
OC-48/STM16 |
1534.2 nm |
ONS-SC-2G-35.0 |
OC-48/STM16 |
1535.0 nm |
ONS-SC-2G-35.8 |
OC-48/STM16 |
1535.8 nm |
ONS-SC-2G-36.6 |
OC-48/STM16 |
1536.6 nm |
ONS-SC-2G-38.1 |
OC-48/STM16 |
1538.1 nm |
ONS-SC-2G-38.9 |
OC-48/STM16 |
1538.9 nm |
ONS-SC-2G-39.7 |
OC-48/STM16 |
1539.7 nm |
ONS-SC-2G-40.5 |
OC-48/STM16 |
1540.5 nm |
ONS-SC-2G-42.1 |
OC-48/STM16 |
1542.1 nm |
ONS-SC-2G-42.9 |
OC-48/STM16 |
1542.9 nm |
ONS-SC-2G-43.7 |
OC-48/STM16 |
1543.7 nm |
ONS-SC-2G-44.5 |
OC-48/STM16 |
1544.5 nm |
ONS-SC-2G-46.1 |
OC-48/STM16 |
1546.1 nm |
ONS-SC-2G-46.9 |
OC-48/STM16 |
1546.9 nm |
ONS-SC-2G-47.7 |
OC-48/STM16 |
1547.7 nm |
ONS-SC-2G-48.5 |
OC-48/STM16 |
1548.5 nm |
ONS-SC-2G-50.1 |
OC-48/STM16 |
1550.1 nm |
ONS-SC-2G-50.9 |
OC-48/STM16 |
1550.9 nm |
ONS-SC-2G-51.7 |
OC-48/STM16 |
1551.7 nm |
ONS-SC-2G-52.5 |
OC-48/STM16 |
1552.5 nm |
ONS-SC-2G-54.1 |
OC-48/STM16 |
1554.1 nm |
ONS-SC-2G-54.9 |
OC-48/STM16 |
1554.9 nm |
ONS-SC-2G-55.7 |
OC-48/STM16 |
1555.7 nm |
ONS-SC-2G-56.5 |
OC-48/STM16 |
1556.5 nm |
ONS-SC-2G-58.1 |
OC-48/STM16 |
1558.1 nm |
ONS-SC-2G-58.9 |
OC-48/STM16 |
1558.9 nm |
ONS-SC-2G-59.7 |
OC-48/STM16 |
1559.7 nm |
ONS-SC-2G-60.6 |
OC-48/STM16 |
1560.6 nm |
1 Typical loss on a 1310-nm wavelength Single-mode fiber is 0.6 dB/km. |
Table A-14 describes the power and noise limited performances parameters for the OC-SC-2G series SFPs.
|
|
|
||
---|---|---|---|---|
Input power range |
-9 to -28 dBm |
At BER = 10-12 with SONET framed PRBS23 622 Mbps - 2.0 Gbps at OSNR1 of 20 dB, 0.1 nm bandwidth 2.0Gbps - 2.7Gbps at OSNR of 21dB, 0.1 nm bandwidth |
-9 to -22 dBm |
At BER = 10-12 with SONET framed PRBS23 At OSNR of 16 dB at 0.1 nm bandwidth |
Dispersion tolerance |
-800 to 3600 dBm |
622 Mbps - 2.0 Gbps Power penalty = 3 dB OSNR = 20 dB at 0.1 nm bandwidth (Noise penalty = 0 dB) |
-800 to 3600 dBm |
622 Mbps - 2.0 Gbps Noise penalty = 2 dB OSNR = 18 dB at 0.1 nm bandwidth (Power penalty = 0 dB) |
-800 to 2400 dBm |
2.0 Gbps - 2.7 Gbps Power penalty = 3 dB OSNR = 21 dB at 0.1 nm bandwidth (Noise penalty = 0 dB) |
-800 to 2400 dBm |
2.0 Gbps - 2.7 Gbps Noise penalty = 3 dB OSNR = 19 dB at 0.1 nm bandwidth (Power penalty = 0 dB) |
1 OSNR |
Table A-15 provides cabling specifications for the single-mode fiber (SMF) SFPs/XFPs. The ports of the listed SFPs/XFPs have LC-type connectors and the minimum cable distance for all SFPs/XFPs listed is 6.5 feet (2 m). Maximum cable distance for all SFPs/XFPs listed is 328 ft (100 m).
|
|
|
|
---|---|---|---|
ONS-SI-622-L2 |
1550 nm |
9 micron SMF |
80 km (49.71 mi.) |
ONS-SE-2G-L2 |
1550 nm |
9 micron SMF |
80 km (49.71 mi.) |
ONS-SE-Z1 |
1310 nm |
9 micron SMF |
15 km (9.3 mi.) |
ONS-SI-155-L2 |
1550 nm |
9 micron SMF |
80 km (49.71 mi.) |
ONS-XC-10G-S1 |
1310 nm |
9 micron SMF |
2 km (1.2 mi.) |
ONS-XC-10G-L2 |
1550 nm |
9 micron SMF |
80 km (49.71 mi.) |
ONS-SI-2G-S1 |
1310 nm |
9 micron SMF |
80 km (49.71 mi.) |
1 Typical loss on a 1310-nm wavelength SMF is 0.6 dB/km. |