- Preface
- Chapter 1, Install the Cisco ONS 15310-CL
- Chapter 2, Install the Cisco ONS 15310-MA
- Chapter 3, Connect the PC and Log Into the GUI
- Chapter 4, Turn Up a Node
- Chapter 5, Turn Up a Network
- Chapter 6, Create Circuits and VT Tunnels
- Chapter 7, Manage Circuits
- Chapter 8, Monitor Performance
- Chapter 9, Manage Alarms
- Chapter 10, Change Port Settings
- Chapter 11, Change Node Settings
- Chapter 12, Upgrade Cards and Spans
- Chapter 13, Convert Network Configurations
- Chapter 14, Add and Remove Nodes
- Chapter 15, Maintain the Node
- Chapter 16, Power Down the Node
- Chapter 17, DLPs C1 to C99
- Chapter 18, DLPs C100 to C199
- Chapter 19, DLPs C200 to C299
- Appendix A, CTC Information and Shortcuts
- Before You Begin
- NTP-C86 Modify Line Settings and PM Parameter Thresholds for Electrical Ports
- NTP-C87 Modify Line Settings and PM Parameter Thresholds for Optical Ports
- NTP-C130 Manage Pluggable Port Modules
- NTP-C92 Change Card or PPM Service State
- NTP-C172 Provision the Soak Timer for an ML-100T-8 Card
Change Port Settings
This chapter explains how to change transmission settings on ports in a Cisco ONS 15310-CL or Cisco ONS 15310-MA.
Before You Begin
Before performing any of the following procedures, investigate all alarms and clear any trouble conditions. Refer to the Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide as necessary.
This section lists the chapter procedures (NTPs). Turn to a procedure for applicable tasks (DLPs).
1. C86 Modify Line Settings and PM Parameter Thresholds for Electrical Ports—Complete as needed.
2. C87 Modify Line Settings and PM Parameter Thresholds for Optical Ports—Complete as needed.
3. C130 Manage Pluggable Port Modules—Complete this procedure to provision, change, or delete pluggable port modules (PPMs), which provide OC-3 or OC-12 line rates for ONS 15310-CL and ONS 15310-MA optical ports.
4. C92 Change Card or PPM Service State—Complete as needed.
5. C172 Provision the Soak Timer for an ML-100T-8 Card—Complete as needed.
NTP-C86 Modify Line Settings and PM Parameter Thresholds for Electrical Ports
Step 1 Complete the "DLP-C29 Log into CTC" task at the node where you want to change the port settings.
Step 2 According to site practice, complete the "NTP-C102 Back Up the Database" procedure to preserve the existing database.
Step 3 Perform any of the following tasks as needed:
•C233 Change Line and Threshold Settings for DS-1 Ports
•C236 Change Line and Threshold Settings for DS-3 Ports
•C237 Change Line and Threshold Settings for the EC-1 Ports
Step 4 When you have finished changing the port settings, complete the "NTP-C102 Back Up the Database" procedure according to site practice.
Stop. You have completed this procedure.
NTP-C87 Modify Line Settings and PM Parameter Thresholds for Optical Ports
Step 1 Complete the "DLP-C29 Log into CTC" task at the node where you want to change the port settings. If you are already logged in, continue with Step 2.
Step 2 According to site practice, complete the "NTP-C102 Back Up the Database" procedure to preserve the existing database.
Step 3 Perform any of the following tasks as needed:
•C238 Change Optical Port Line Settings
•C239 Change Optical Port SONET Thresholds Settings
•C224 Change Optics Thresholds Settings for Optical Ports
Note To modify settings on the SONET STS tab, see the "DLP-C99 Enable Intermediate-Path Performance Monitoring" task.
Step 4 According to site practice, complete the "NTP-C102 Back Up the Database" procedure.
Stop. You have completed this procedure.
NTP-C130 Manage Pluggable Port Modules
Step 1 Complete the "DLP-C29 Log into CTC" task at the node where you want to manage PPMs.
Step 2 Click the Alarms tab:
a. Verify that the alarm filter is not turned on. See the "DLP-C88 Disable Alarm Filtering" task as necessary.
b. Verify that no unexplained conditions appear on the network. If unexplained conditions appear, resolve them before continuing. Refer to the Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide.
c. Complete the "DLP-C223 Export CTC Data" task to export alarm and condition information.
Step 3 As needed, complete the "DLP-C192 Provision a Multirate Pluggable Port Module" task. If you preprovisioned a multirate SFP, skip this task and continue with Step 4.
Step 4 As needed, complete the "DLP-C193 Provision the Optical Line Rate" task to assign an OC-3 or OC-12 line rate.
Step 5 As needed, complete the "DLP-C194 Change the Optical Line Rate" task to change the line rate on a multirate PPM.
Step 6 As needed, complete the "DLP-C195 Delete Pluggable Port Modules" task.
Step 7 Stop. You have completed this procedure.
NTP-C92 Change Card or PPM Service State
Purpose |
This procedure changes the card or port service state, which is an autonomously generated state that gives the overall condition of the port. |
Tools/Equipment |
None |
Prerequisite Procedures |
Chapter 1 "Install the Cisco ONS 15310-CL" |
Required/As Needed |
As needed |
Onsite/Remote |
Onsite or remote |
Security Level |
Provisioning or higher |
Note On the ONS 15310-CL and ONS 15310-MA, the pluggable-port module (PPM) is equivalent to an optical port.
Step 1 Complete the "DLP-C29 Log into CTC" task at the node where you want to change card or PPM service state.
Step 2 Click the Inventory tab.
Step 3 Click Admin State for the card or PPM that you want to change, and choose an administrative state from the drop-down list: IS or OOS,MT.
Step 4 Click Apply.
Step 5 If an error message appears indicating that the card or PPM service state cannot be changed from its current service state, click OK.
Depending on the administrative state that you choose, the card or port/PPM transitions to a different service state. For more information about the service states and card state transitions, refer to the "Administrative and Service States" appendix of the Cisco ONS 15310-CL and Cisco ONS 15310-MA Reference Manual.
Stop. You have completed this procedure.
NTP-C172 Provision the Soak Timer for an ML-100T-8 Card
Step 1 Complete the "DLP-C29 Log into CTC" task at the node where you want to provision the soak timer for an ML-100T-8 card. If you are already logged in, continue with Step 2.
Step 2 In node view, double-click the ML-100T-8 card that you want to provision.
Step 3 Click the Provisioning tab.
Step 4 Click the Ether Ports or POS Ports subtabs and complete the following:
•PSAS—Check to enable Pre-Service Alarm Suppression (PSAS), which suppresses all alarms on the port for the time designated in the Soak Time column.
•Soak Time—Choose the desired soak time (in hours and minutes). Use this column when you have checked PSAS to suppress alarms. Once the port detects a signal, the countdown begins for the designated soak time. Soak time hours can be set from 0 to 48. Soak time minutes can be set from 0 to 45 in 15 minute increments.
Step 5 Click Apply.
Stop. You have completed this procedure.