- Preface
- Product Overview
- Command-line Interfaces
- Configuring the Switch for the First Time
- Administering the Switch
- Configuring Supervisor Engine Redundancy Using RPR and SSO
- Configuring the Cisco IOS In Service Software Upgrade Process
- Configuring Interfaces
- Checking Port Status and Connectivity
- Configuring Cisco NSF with SSO Supervisor Engine Redundancy
- Environmental Monitoring and Power Management
- Configuring Power over Ethernet
- Configuring VLANs, VTP, and VMPS
- Configuring IP Unnumbered Interface
- Configuring Layer 2 Ethernet Interfaces
- Configuring SmartPort Macros
- Configuring STP and MST
- Configuring Optional STP Features
- Configuring EtherChannels
- Configuring CDP
- Configuring IGMP Snooping and Filtering
- Configuring IPv6 MLD Snooping
- Configuring LLDP and LLDP-MED
- Configuring UDLD
- Configuring Unidirectional Ethernet
- Configuring Layer 3 Interfaces
- Configuring Cisco Express Forwarding
- Configuring Unicast Reverse Path Forwarding
- Configuring IP Multicast
- Configuring Policy-Based Routing
- Configuring VRF-lite
- Flexible NetFlow
- Configuring Quality of Service
- Configuring Voice Interfaces
- Configuring Private VLANs
- Configuring 802.1X Port-Based Authentication
- Configuring Web-Based Authentication
- Configuring Port Security
- Configuring Control Plane Policing
- Configuring DHCP Snooping, IP Source Guard, and IPSG for Static Hosts
- Configuring Dynamic ARP Inspection
- Configuring Network Security with ACLs
- Support for IPv6
- Port Unicast and Multicast Flood Blocking
- Configuring Storm Control
- Configuring SPAN and RSPAN
- Configuring System Message Logging
- Configuring OBFL
- Configuring SNMP
- Configuring Cisco IOS IP SLAs Operations
- Configuring RMON
- Configuring Call Home
- Performing Diagnostics
- ROM Monitor
- Configuring MIB Support
- Acronyms
- Index
Configuring Cisco Express Forwarding
This chapter describes Cisco Express Forwarding (CEF) on the Catalyst 4000 family switch. It also provides guidelines, procedures, and examples to configure this feature.
This chapter includes the following major sections:
•Catalyst 4500 Series Switch Implementation of CEF
•CEF Configuration Restrictions
•Monitoring and Maintaining CEF
Note For complete syntax and usage information for the switch commands used in this chapter, look at the Cisco Catalyst 4500 Series Switch Command Reference and related publications at this location:
http://www.cisco.com/en/US/products/hw/switches/ps4324/index.html
If the command is not found in the Catalyst 4500 Command Reference, it is located in the larger Cisco IOS library. Refer to the Catalyst 4500 Series Switch Cisco IOS Command Reference and related publications at this location:
http://www.cisco.com/en/US/products/ps6350/index.html
About CEF
This section contains information on the two primary components that comprise the CEF operation:
Benefits of CEF
CEF is advanced Layer 3 IP switching technology that optimizes performance and scalability for large networks with dynamic traffic patterns or networks with intensive web-based applications and interactive sessions.
CEF provides the following benefits:
•Improves performance over the caching schemes of multilayer switches, which often flush the entire cache when information changes in the routing tables.
•Provides load balancing that distributes packets across multiple links based on Layer 3 routing information. If a network device discovers multiple paths to a destination, the routing table is updated with multiple entries for that destination. Traffic to that destination is then distributed among the various paths.
CEF stores information in several data structures rather than the route cache of multilayer switches. The data structures optimize lookup for efficient packet forwarding.
Forwarding Information Base
The Forwarding Information Base (FIB) is a table that contains a copy of the forwarding information in the IP routing table. When routing or topology changes occur in the network, the route processor updates the IP routing table and CEF updates the FIB. Because there is a one-to-one correlation between FIB entries and routing table entries, the FIB contains all known routes and eliminates the need for route cache maintenance that is associated with switching paths, such as fast switching and optimum switching. CEF uses the FIB to make IP destination-based switching decisions and maintain next-hop address information based on the information in the IP routing table.
On the Catalyst 4500 series switches, CEF loads the FIB in to the Integrated Switching Engine hardware to increase the performance of forwarding. The Integrated Switching Engine has a finite number of forwarding slots for storing routing information. If this limit is exceeded, CEF is automatically disabled and all packets are forwarded in software. In this situation, you should reduce the number of routes on the switch and then reenable hardware switching with the ip cef command.
Adjacency Tables
In addition to the FIB, CEF uses adjacency tables to prepend Layer 2 addressing information. Nodes in the network are said to be adjacent if they are within a single hop from each other. The adjacency table maintains Layer 2 next-hop addresses for all FIB entries.
Adjacency Discovery
The adjacency table is populated as new adjacent nodes are discovered. Each time an adjacency entry is created (such as through the Address Resolution Protocol (ARP), a link-layer header for that adjacent node is stored in the adjacency table. Once a route is determined, the link-layer header points to a next hop and corresponding adjacency entry. The link-layer header is subsequently used for encapsulation during CEF switching of packets.
Adjacency Resolution
A route might have several paths to a destination prefix, such as when a router is configured for simultaneous load balancing and redundancy. For each resolved path, a pointer is added for the adjacency corresponding to the next-hop interface for that path. This mechanism is used for load balancing across several paths.
Adjacency Types That Require Special Handling
In addition to adjacencies for next-hop interfaces (host-route adjacencies), other types of adjacencies are used to expedite switching when certain exception conditions exist. When the prefix is defined, prefixes requiring exception processing are cached with one of the special adjacencies listed in Table 27-1.
Unresolved Adjacency
When a link-layer header is prepended to packets, FIB requires the prepend to point to an adjacency corresponding to the next hop. If an adjacency was created by FIB and was not discovered through a mechanism such as ARP, the Layer 2 addressing information is not known and the adjacency is considered incomplete. When the Layer 2 information is known, the packet is forwarded to the route processor, and the adjacency is determined through ARP.
Catalyst 4500 Series Switch Implementation of CEF
This section contains the following subsections:
•Hardware and Software Switching
Catalyst 4000 Family switches support an ASIC-based Integrated Switching Engine that provides these features:
•Ethernet bridging at Layer 2
•IP routing at Layer 3
Because the ASIC is specifically designed to forward packets, the Integrated Switching Engine hardware can run this process much faster than CPU subsystem software.
Figure 27-1 shows a high-level view of the ASIC-based Layer 2 and Layer 3 switching process on the Integrated Switching Engine.
Figure 27-1 Logical L2 and L3 Switch Components
The Integrated Switching Engine performs inter-VLAN routing on logical Layer 3 interfaces with the ASIC hardware. The ASIC hardware also supports a physical Layer 3 interface that can be configured to connect with a host, a switch, or a router.
Hardware and Software Switching
For the majority of packets, the Integrated Switching Engine performs the packet forwarding function in hardware. These packets are hardware-switched at very high rates. Exception packets are forwarded by the CPU subsystem software. Statistic reports should show that the Integrated Switching Engine is forwarding the vast majority of packets in hardware. Software forwarding is significantly slower than hardware forwarding, but packets forwarded by the CPU subsystem do not reduce hardware forwarding speed.
Figure 27-2 shows a logical view of the Integrated Switching Engine and the CPU subsystem switching components.
Figure 27-2 Hardware and Software Switching Components
The Integrated Switching Engine performs inter-VLAN routing in hardware. The CPU subsystem software supports Layer 3 interfaces to VLANs that use Subnetwork Access Protocol (SNAP) encapsulation. The CPU subsystem software also supports generic routing encapsulation (GRE) tunnel.
Hardware Switching
Hardware switching is the normal operation for the Catalyst 4500 series switch.
Software Switching
Software switching occurs when traffic cannot be processed in hardware. The following types of exception packets are processed in software at a much slower rate:
•Packets that use IP header options
Note Packets that use TCP header options are switched in hardware because they do not affect the forwarding decision.
•Packets that have an expiring IP time-to-live (TTL) counter
•Packets that are forwarded to a tunnel interface
•Packets that arrive with non-supported encapsulation types
•Packets that are routed to an interface with non-supported encapsulation types
•Packets that exceed the MTU of an output interface and must be fragmented
•Packets that require an IGMP redirect to be routed
Load Balancing
The Catalyst 4000 family switch supports load balancing for routing packets in the Integrated Switching Engine hardware. Load balancing is always enabled. It works when multiple routes for the same network with different next-hop addresses are configured. These routes can be configured either statically or through a routing protocol such as OSPF or EIGRP.
The hardware makes a forwarding decision by using a hardware load sharing hash function to compute a value, based on the source and destination IP addresses and the source and destination TCP port numbers (if available). This load sharing hash value is then used to select which route to use to forward the packet. All hardware switching within a particular flow (such as a TCP connection) is routed to the same next hop, thereby reducing the chance that packet reordering occurs. Up to eight different routes for a particular network are supported.
Software Interfaces
Cisco IOS for the Catalyst 4000 family switch supports GRE and IP tunnel interfaces that are not part of the hardware forwarding engine. All packets that flow to or from these interfaces must be processed in software and has a significantly lower forwarding rate than that of hardware-switched interfaces. Also, Layer 2 features are not supported on these interfaces.
CEF Configuration Restrictions
The Integrated Switching Engine supports only ARPA and ISL/802.1q encapsulation types for Layer 3 switching in hardware. The CPU subsystem supports a number of encapsulations such as SNAP for Layer 2 switching that you can use for Layer 3 switching in software.
Configuring CEF
These sections describe how to configure CEF:
•Configuring Load Balancing for CEF
Enabling CEF
By default, CEF is enabled globally on the Catalyst 4000 family switch. No configuration is required.
To reenable CEF, perform this task:
|
|
---|---|
Switch(config)# ip cef distributed |
Enables standard CEF operation. |
Configuring Load Balancing for CEF
CEF load balancing is based on a combination of source and destination packet information; it allows you to optimize resources by distributing traffic over multiple paths for transferring data to a destination. You can configure load balancing on a per-destination basis. Load-balancing decisions are made on the outbound interface. You can configure per-destination load balancing for CEF on outbound interfaces.
The following topics are discussed:
•Configuring Per-Destination Load Balancing
•Configuring Load Sharing Hash Function
Configuring Per-Destination Load Balancing
Per-destination load balancing is enabled by default when you enable CEF. To use per-destination load balancing, you do not perform any additional tasks once you enable CEF.
Per-destination load balancing allows the router to use multiple paths to achieve load sharing. Packets for a given source-destination host pair are guaranteed to take the same path, even if multiple paths are available. Traffic destined for different pairs tend to take different paths. Per-destination load balancing is enabled by default when you enable CEF; it is the load balancing method of choice in most situations.
Because per-destination load balancing depends on the statistical distribution of traffic, load sharing becomes more effective as the number of source-destination pairs increases.
You can use per-destination load balancing to ensure that packets for a given host pair arrive in order. All packets for a certain host pair are routed over the same link or links.
Configuring Load Sharing Hash Function
When multiple unicast routes exist to a particular destination IP prefix, the hardware sends packets matching that prefix across all possible routes, thereby sharing the load across all next hop routers. By default, the route used is chosen by computing a hash of the source and destination IP addresses and using the resulting value to select the route. This preserves packet ordering for packets within a flow by ensuring that all packets within a single IP source/destination flow are sent on the same route, but it provides a near-random distribution of flows to routes.
The load-sharing hash function can be changed, so that in addition to the source and destination IP addresses, the source TCP/UDP port, the destination TCP/UDP port, or both can also be included in the hash.
To the configure load sharing hash function to use the source and/or destination ports, perform this task:
Note The include-ports option does not apply to software-switched traffic on the Catalyst 4500 series switches.
Viewing CEF Information
You can view the collected CEF information. To view CEF information, perform this task:
|
|
---|---|
Switch# show ip cef |
Displays the collected CEF information. |
Monitoring and Maintaining CEF
To display information about IP traffic, perform this task:
|
|
---|---|
Switch# show interface type slot/interface | begin L3 |
Displays a summary of IP unicast traffic. |
This example shows how to display information about IP unicast traffic on interface Fast Ethernet 3/3:
Switch# show interface fastethernet 3/3 | begin L3
L3 in Switched: ucast: 0 pkt, 0 bytes - mcast: 12 pkt, 778 bytes mcast
L3 out Switched: ucast: 0 pkt, 0 bytes - mcast: 0 pkt, 0 bytes
4046399 packets input, 349370039 bytes, 0 no buffer
Received 3795255 broadcasts, 2 runts, 0 giants, 0 throttles
<...output truncated...>
Switch#
Note The IP unicast packet count is updated approximately every five seconds.
Displaying IP Statistics
IP unicast statistics are gathered on a per-interface basis. To display IP statistics, perform this task:
|
|
---|---|
Switch# show interface type number counters detail |
Displays IP statistics. |
This example shows how to display IP unicast statistics for Part 3/1:
Switch# show interface fastethernet 3/1 counters detail
Port InBytes InUcastPkts InMcastPkts InBcastPkts
Fa3/1 7263539133 5998222 6412307 156
Port OutBytes OutUcastPkts OutMcastPkts OutBcastPkts
Fa3/1 7560137031 5079852 12140475 38
Port InPkts 64 OutPkts 64 InPkts 65-127 OutPkts 65-127
Fa3/1 11274 168536 7650482 12395769
Port InPkts 128-255 OutPkts 128-255 InPkts 256-511 OutPkts 256-511
Fa3/1 31191 55269 26923 65017
Port InPkts 512-1023 OutPkts 512-1023
Fa3/1 133807 151582
Port InPkts 1024-1518 OutPkts 1024-1518 InPkts 1519-1548 OutPkts 1519-1548
Fa3/1 N/A N/A N/A N/A
Port InPkts 1024-1522 OutPkts 1024-1522 InPkts 1523-1548 OutPkts 1523-1548
Fa3/1 4557008 4384192 0 0
Port Tx-Bytes-Queue-1 Tx-Bytes-Queue-2 Tx-Bytes-Queue-3 Tx-Bytes-Queue-4
Fa3/1 64 0 91007 7666686162
Port Tx-Drops-Queue-1 Tx-Drops-Queue-2 Tx-Drops-Queue-3 Tx-Drops-Queue-4
Fa3/1 0 0 0 0
Port Rx-No-Pkt-Buff RxPauseFrames TxPauseFrames PauseFramesDrop
Fa3/1 0 0 0 N/A
Port UnsupOpcodePause
Fa3/1 0
Switch#
To display CEF (software switched) and hardware IP unicast adjacency table information, perform this task:
|
|
---|---|
Switch# show adjacency [interface] [detail | internal | summary] |
Displays detailed adjacency information, including Layer 2 information, when the optional detail keyword is used. |
This example shows how to display adjacency statistics:
Switch# show adjacency gigabitethernet 3/5 detail
Protocol Interface Address
IP GigabitEthernet9/5 172.20.53.206(11)
504 packets, 6110 bytes
00605C865B82
000164F83FA50800
ARP 03:49:31
Note Adjacency statistics are updated approximately every 10 seconds.