Configuring Private VLANs


This chapter describes how to implement private VLANs (PVLANs) on Catalyst 4500 series switches. It also provides restrictions, procedures, and configuration examples.

This chapter includes the following major sections:

Command List

Private VLANs

Configuring PVLANs


Note For complete syntax and usage information for the switch commands used in this chapter, look at the Cisco Catalyst 4500 Series Switch Command Reference and related publications at this location:

http://www.cisco.com/en/US/products/hw/switches/ps4324/index.html

If the command is not found in the Catalyst 4500 Command Reference, it is located in the larger Cisco IOS library. Refer to the Catalyst 4500 Series Switch Cisco IOS Command Reference and related publications at this location:

http://www.cisco.com/en/US/products/ps6350/index.html


Command List

This table lists the commands most commonly used with PVLANs.

Command
Purpose
Location

private-vlan {community | isolated | primary}

Configures a VLAN as a PVLAN.

Configuring a VLAN as a PVLAN

private-vlan association {secondary_vlan_list | add secondary_vlan_list | remove secondary_vlan_list}

Associates the secondary VLAN with the primary VLAN.

The list can contain only one isolated VLAN ID; it can also contain multiple community VLAN IDs.

Associating a Secondary VLAN with a Primary VLAN

show vlan private-vlan [type]

Verifies the configuration.

Configuring a VLAN as a PVLAN

Associating a Secondary VLAN with a Primary VLAN

show interface private-vlan mapping

Verifies the configuration.

Permitting Routing of Secondary VLAN Ingress Traffic

switchport mode private-vlan {host | promiscuous | trunk promiscuous | trunk [secondary]}

Configures a Layer 2 interface as a PVLAN port.

Configuring PVLANs

switchport private-vlan mapping [trunk] primary_vlan_ID {secondary_vlan_list | add secondary_vlan_list | remove secondary_vlan_list}

Maps the PVLAN promiscuous port to a primary VLAN and to selected secondary VLANs.

Configuring a Layer 2 Interface as a PVLAN Promiscuous Port

Configuring a Layer 2 Interface as a Promiscuous PVLAN Trunk Port

Switch(config-if)# switchport private-vlan host-association primary_vlan_ID secondary_vlan_ID

Associates the Layer 2 interface with a PVLAN.

Note You can associate only one primay-secondary VLAN pair to the isolated port.

Configuring a Layer 2 Interface as a PVLAN Host Port

switchport private-vlan association trunk primary_vlan_ID secondary_vlan_ID

Configures association between primary VLANs and secondary VLANs the PVLAN trunk port with a PVLAN.

Note You can configure the isolated trunk port with multiple primary-secondary pair.

Configuring a Layer 2 Interface as an Isolated PVLAN Trunk Port

switchport private-vlan trunk allowed vlan vlan_list all | none | [add | remove | except] vlan_atom[,vlan_atom...]

Configures a list of allowed normal VLANs on a PVLAN trunk port.

Configuring a Layer 2 Interface as an Isolated PVLAN Trunk Port

switchport private-vlan trunk native vlan vlan_id

Configures a VLAN to which untagged packets (as in IEEE 802.1Q tagging) are assigned on a PVLAN trunk port.

Configuring a Layer 2 Interface as an Isolated PVLAN Trunk Port


Private VLANs

The private VLAN feature addresses two problems that service providers face when using VLANs:

The switch supports up to 1005 active VLANs. If a service provider assigns one VLAN per customer, this limits the numbers of customers the service provider can support.

To enable IP routing, each VLAN is assigned a subnet address space or a block of addresses, which can result in wasting the unused IP addresses, and cause IP address management problems.

Using private VLANs provides scalability and IP address management benefits for service providers and Layer 2 security for customers. Private VLANs partition a regular VLAN domain into subdomains. A subdomain is represented by a pair of VLANs: a primary VLAN and a secondary VLAN. A private VLAN can have multiple VLAN pairs, one pair for each subdomain. All VLAN pairs in a private VLAN share the same primary VLAN. The secondary VLAN ID differentiates one subdomain from another. See Figure 35-1.

Figure 35-1 Private-VLAN Domain

There are two types of secondary VLANs:

Isolated VLANs—Ports within an isolated VLAN cannot communicate with each other at the Layer 2 level.

Community VLANs—Ports within a community VLAN can communicate with each other but cannot communicate with ports in other communities at the Layer 2 level.

A promiscuous port can serve only one primary VLAN, one isolated VLAN, and multiple community VLANs. Layer 3 gateways are typically connected to the switch through a promiscuous port.

In a switched environment, you can assign an individual private VLAN and associated IP subnet to each individual or common group of end stations. The end stations need to communicate only with a default gateway to communicate outside the private VLAN.

You can use private VLANs to control access to end stations in these ways:

Configure selected interfaces connected to end stations as isolated ports to prevent any communication at Layer 2. For example, if the end stations are servers, this configuration prevents Layer 2 communication between the servers.

Configure interfaces connected to default gateways and selected end stations (such as, backup servers) as promiscuous ports to allow all end stations access to a default gateway.

Reduce VLAN and IP subnet consumption; you can prevent traffic between end stations even though they are in the same VLAN and IP subnet.

With a promiscuous port, you can connect a wide range of devices as access points to a PVLAN. For example, you can connect a promiscuous port to the server port of a LocalDirector to connect an isolated VLAN or a number of community VLANs to the server. LocalDirector can load balance the servers present in the isolated or community VLANs, or use a promiscuous port to monitor or back up all the PVLAN servers from an administration workstation.

This section includes the following topics:

Definition Table

Private VLANs across Multiple Switches

Private-VLAN Interaction with Other Features

Definition Table

Term
Definition

Private VLANs

Private VLANs are sets of VLAN pairs that share a common primary identifier and provide a mechanism for achieving layer-2 separation between ports while sharing a single layer-3 router port and IP subnet.

Secondary VLAN

A type of VLAN used to implement private VLANs. Secondary VLANs are associated with a primary VLAN, and are used to carry traffic from hosts to other allowed hosts or to routers.

Community Port

A community port is a host port that belongs to a community secondary VLAN. Community ports communicate with other ports in the same community VLAN and with promiscuous ports. These interfaces are isolated at Layer 2 from all other interfaces in other communities and from isolated ports within their private VLAN.

Community VLAN

Community VLAN—A community VLAN is a secondary VLAN that carries upstream traffic from the community ports to the promiscuous port gateways and to other host ports in the same community. You can configure multiple community VLANs in a private VLAN.

Isolated Port

An isolated port is a host port that belongs to an isolated secondary VLAN. It has complete Layer 2 separation from other ports within the same private VLAN, except for the promiscuous ports. Private VLANs block all traffic to isolated ports except traffic from promiscuous ports. Traffic received from an isolated port is forwarded only to promiscuous ports.

Isolated VLAN

Isolated VLAN —A private VLAN has only one isolated VLAN. An isolated VLAN is a secondary VLAN that carries unidirectional traffic upstream from the hosts toward the promiscuous ports and the gateway.

Primary VLAN

Primary VLAN—A private VLAN has only one primary VLAN. Every port in a private VLAN is a member of the primary VLAN. The primary VLAN carries unidirectional traffic downstream from the promiscuous ports to the (isolated and community) host ports and to other promiscuous ports.

Private VLAN Trunk Port

A PVLAN trunk port can carry multiple secondary (isolated only) and non-PVLANs. Packets are received and transmitted with secondary or regular VLAN tags on the PVLAN trunk ports.

Note Only IEEE 802.1q encapsulation is supported.

Promiscuous Port

A promiscuous port belongs to the primary VLAN and can communicate with all interfaces, including the community and isolated host ports and private VLAN trunk ports that belong to the secondary VLANs associated with the primary VLAN.

Promiscuous Trunk Port

A promiscuous trunk port can carry multiple primary and normal VLANs. Packets are received and transmitted with primary or regular VLAN tags. Other than that, the port behaves just like a promiscuous access port.

Note Only IEEE 802.1q encapsulation is supported.

Private VLANs across Multiple Switches

This section discusses the following topics:

Standard Trunk Ports

Isolated Private VLAN Trunk Ports

Promiscuous Private VLAN Trunk Ports

Standard Trunk Ports

As with regular VLANs, private VLANs can span multiple switches. A trunk port carries the primary VLAN and secondary VLANs to a neighboring switch. The trunk port treats the private VLAN as any other VLAN. A feature of private VLANs across multiple switches is that traffic from an isolated port in switch A does not reach an isolated port on Switch B. See Figure 35-2.

To maintain the security of your private-VLAN configuration and to avoid other use of the VLANs configured as private VLANs, configure private VLANs on all intermediate devices, including devices that have no private-VLAN ports.


Note Trunk ports carry traffic from regular VLANs and also from primary, isolated, and community VLANs.



Note You should use standard trunk ports if both switches undergoing trunking support PVLANs.


Figure 35-2 Private VLANs across Switches

Because VTP does not support private VLANs, you must manually configure private VLANs on all switches in the Layer 2 network. If you do not configure the primary and secondary VLAN association in some switches in the network, the Layer 2 databases in these switches are not merged. This can result in unnecessary flooding of private-VLAN traffic on those switches.

Isolated Private VLAN Trunk Ports

You would use a isolated PVLAN trunk ports when you would anticipate using PVLAN isolated host ports to carry multiple VLANs, either normal VLANs or for multiple PVLAN domains. This makes it useful for connecting a downstream switch that does not support PVLANs (like Catalyst 2950).

Figure 35-3 Isolated PVLAN Trunk Ports

In this illustration, a Catalyst 4500 switch is being used to connect a downstream switch that does not support PVLANs.

Traffic being sent in the downstream direction towards host1 from the router is received by the
Catalyst  4500 series switch on the promiscuous port and in the primary VLAN (VLAN 10). The packets are then switched out of the isolated PVLAN trunk, but rather than being tagged with the primary VLAN (VLAN 10) they are instead transmitted with the isolated VLAN's tag (VLAN 11). In this way, when the packets arrive on the non-PVLAN switch, they can be bridged to the destination host's access port.

Traffic in the upstream direction is sent by host1 to the non-PVLAN switch, arriving in VLAN 11. The packets are then transmitted to the Catalyst 4500 series switch tagged with that VLAN's tag (VLAN 11) over the trunk port. On the Catalyst 4500 series switch, VLAN 11 is configured as the isolated vlan, and the traffic is forwarded as if it came from an isolated host port.


Note When an isolated trunk is used in this fashion, the Catalyst 4500 series switch provides isolation between the isolated trunk and directly connected hosts (such as host3), but not between hosts connected to the non-PVLAN switch (such as host1 and host2). Isolation between these hosts must be provided by the non-PVLAN switch, using a feature such as protected ports on a Catalyst 2950.


For details on protected ports, see the URL:

http://www.cisco.com/en/US/docs/switches/lan/catalyst2950/software/release/12.1_22_ea11x/configuration/guide/swtrafc.html#wp1158863

Promiscuous Private VLAN Trunk Ports

PVLAN Promiscuous Trunks are used in situations where one would normally use a PVLAN promiscuous host port but where it is necessary to carry multiple vlans, either normal vlans or for multiple PVLAN domains. This makes it useful for connecting an upstream router that does not support Private VLANs, such as a Cisco 7200.

Figure 35-4 Promiscuous PVLAN Trunk Ports

In this illustration, a Catalyst 4500 series switch is being used to connect a PVLAN domain to an upstream router which does not support PVLANs. Traffic being sent upstream by host1 arrives on the
Catalyst 4500 series switch in the community VLAN (VLAN 12). When this traffic is bridged onto the promiscuous PVLAN trunk towards the router, it is tagged with the primary VLAN (VLAN 10), so that it can be routed via the correct subinterface configured on the router.

Traffic in the downstream direction is received on the promiscuous PVLAN trunk port by the
Catalyst  4500  switch in the primary VLAN (VLAN 10), just as if it had been received on a promiscous host port. It can then be bridged to the destination host as in any PVLAN domain.

PVLAN promiscuous trunks interact with VLAN QoS. Refer to the section "PVLANs and VLAN ACL/QoS" section.

Private-VLAN Interaction with Other Features

Private VLANs have specific interaction with some other features, described in these sections:

PVLANs and VLAN ACL/QoS

Private VLANs and Unicast, Broadcast, and Multicast Traffic

Private VLANs and SVIs

Per-Virtual-Port Error Disable on Private Vlans

For details, see the section "PVLAN Configuration Guidelines and Restrictions" on page 11.

PVLANs and VLAN ACL/QoS

PVLAN ports use primary and secondary VLANs, as follows:

A packet received on a PVLAN host port belongs to the secondary VLAN.

A packet received on a PVLAN trunk port belongs to the secondary VLAN if the packet is tagged with a secondary VLAN or if the packet is untagged and the native VLAN on the port is a secondary VLAN.

A packet received on a PVLAN host or trunk port and assigned to a secondary VLAN is bridged on the secondary VLAN. Because of this bridging, the secondary VLAN ACL as well as the secondary VLAN QoS (on input direction) apply.

When a packet is transmitted out of a PVLAN host or trunk port, the packet logically belongs to the primary VLAN. This relationship applies even though the packet may be transmitted with the secondary VLAN tagging for PVLAN trunk ports. In this situation, the primary VLAN ACL and the primary VLAN QoS on output apply to the packet.

Similarly, a packet received on a PVLAN promiscuous access port belongs to primary VLAN.

A packet received on a PVLAN promiscuous trunk port could belong to the primary VLAN or normal VLAN depending on incoming VLAN.

For traffic flowing in normal VLAN on promiscuous trunk ports, normal VLAN ACL and QoS policies apply. For traffic flowing in a private VLAN domain, a packet received on a promiscuous port is bridged in primary VLAN. Therefore, the primary VLAN ACL and QoS policies apply on input.

When a packet is transmitted out of a promiscuous trunk port, the packet could logically belong to secondary VLAN if received from a secondary port, or in primary VLAN if bridged from another promiscuous port. Because we cannot differentiate between both packets, all VLAN QoS policies are ignored on packets egressing promiscuous trunk ports.

Private VLANs and Unicast, Broadcast, and Multicast Traffic

In regular VLANs, devices in the same VLAN can communicate with each other at the Layer 2 level, but devices connected to interfaces in different VLANs must communicate at the Layer 3 level. In private VLANs, the promiscuous ports are members of the primary VLAN, while the host ports belong to secondary VLANs. Because the secondary VLAN is associated to the primary VLAN, members of the these VLANs can communicate with each other at the Layer 2 level.

In a regular VLAN, broadcasts are forwarded to all ports in that VLAN. Private VLAN broadcast forwarding depends on the port sending the broadcast:

An isolated port sends a broadcast only to the promiscuous ports or trunk ports.

A community port sends a broadcast to all promiscuous ports, trunk ports, and ports in the same community VLAN.

A promiscuous port sends a broadcast to all ports in the private VLAN (other promiscuous ports, trunk ports, isolated ports, and community ports).

Multicast traffic is routed or bridged across private-VLAN boundaries and within a single community VLAN. Multicast traffic is not forwarded between ports in the same isolated VLAN or between ports in different secondary VLANs.

Private VLANs and SVIs

In a Layer 3 switch, a switch virtual interface (SVI) represents the Layer 3 interface of a VLAN. Layer 3 devices communicate with a private VLAN only through the primary VLAN and not through secondary VLANs. Configure Layer 3 VLAN interfaces (SVIs) only for primary VLANs. You cannot configure Layer 3 VLAN interfaces for secondary VLANs. SVIs for secondary VLANs are inactive while the VLAN is configured as a secondary VLAN.

If you try to configure a VLAN with an active SVI as a secondary VLAN, the configuration is not allowed until you disable the SVI.

If you try to create an SVI on a VLAN that is configured as a secondary VLAN and the secondary VLAN is already mapped at Layer 3, the SVI is not created, and an error is returned. If the SVI is not mapped at Layer 3, the SVI is created, but it is automatically shut down.

When the primary VLAN is associated with and mapped to the secondary VLAN, any configuration on the primary VLAN is propagated to the secondary VLAN SVIs. For example, if you assign an IP subnet to the primary VLAN SVI, this subnet is the IP subnet address of the entire private VLAN.

Per-Virtual-Port Error Disable on Private Vlans

For private VLANs, per-vp error disable behavior is defined as follows:

On a PVLAN promiscuous or promiscuous trunk ports, if a violation occurs on the primary VLAN, it is error disabled.

On a PVLAN host or trunk port, if a violation occurs on the secondary VLAN, the associated primary VLAN is error disabled.

On a standard trunk port that carries both primary and secondary VLANs, if a violation occurs on the primary VLAN, this VLAN and all its associated secondary VLANs are error disabled. If a violation occurs on a secondary VLAN, the associated primary VLAN and all its associated secondary VLANs are error disabled.

Configuring PVLANs

These sections describe how to configure PVLANs:

Tasks for Configuring Private VLANs

Default Private-VLAN Configuration

PVLAN Configuration Guidelines and Restrictions

Configuring a VLAN as a PVLAN

Associating a Secondary VLAN with a Primary VLAN

Configuring a Layer 2 Interface as a PVLAN Promiscuous Port

Configuring a Layer 2 Interface as a PVLAN Host Port

Configuring a Layer 2 Interface as an Isolated PVLAN Trunk Port

Configuring a Layer 2 Interface as a Promiscuous PVLAN Trunk Port

Permitting Routing of Secondary VLAN Ingress Traffic

Tasks for Configuring Private VLANs

To configure a PVLAN, follow these steps:


Step 1 Set VTP mode to transparent. See the "VLAN Trunking Protocol" section.

Step 2 Create the secondary VLANs. See the "Configuring a VLAN as a PVLAN" section.

Step 3 Create the primary VLAN. See the "Configuring a VLAN as a PVLAN" section.

Step 4 Associate the secondary VLAN to the primary VLAN. See the "Associating a Secondary VLAN with a Primary VLAN" section.


Note Only one isolated VLAN can be mapped to a primary VLAN, but more than one community VLAN can be mapped to a primary VLAN.


Step 5 Configure an interface as an isolated or community host or trunk port. See the "Configuring a Layer 2 Interface as a PVLAN Host Port" section and "Configuring a Layer 2 Interface as an Isolated PVLAN Trunk Port" section.

Step 6 Associate the isolated port or community port to the primary-secondary VLAN pair. See the "Associating a Secondary VLAN with a Primary VLAN" section.

Step 7 Configure an interface as a promiscuous port. See the "Configuring a Layer 2 Interface as a PVLAN Promiscuous Port" section.

Step 8 Map the promiscuous port to the primary-secondary VLAN pair. See the "Configuring a Layer 2 Interface as a PVLAN Promiscuous Port" section.

Step 9 If you plan to use inter-VLAN routing, configure the primary SVI, and map secondary VLANs to the primary. See the "Permitting Routing of Secondary VLAN Ingress Traffic" section.

Step 10 Verify private-VLAN configuration. See the "Switch#" section.


Default Private-VLAN Configuration

No private VLANs are configured.

PVLAN Configuration Guidelines and Restrictions

Follow these guidelines when configuring PVLANs:

To configure a PVLAN correctly, enable VTP in transparent mode in VTP version 1 and
VTP version 2. (VTP version 3 enables you to create it in server mode).

You cannot change the VTP mode to client or server for PVLANs.

Do not include VLAN 1 or VLANs 1002 through 1005 in PVLANs.

Use only PVLAN commands to assign ports to primary, isolated, or community VLANs.

Layer 2 interfaces on primary, isolated, or community VLANs are inactive in PVLANs. Layer 2 trunk interfaces remain in the STP forwarding state.

You cannot configure Layer 3 VLAN interfaces for secondary VLANs.

Layer 3 VLAN interfaces for isolated and community (secondary) VLANs are inactive while the VLAN is configured as an isolated or community VLAN.

Do not configure private VLAN ports as EtherChannels. While a port is part of the private VLAN configuration, its associated EtherChannel configuration is inactive.

Do not apply dynamic access control entries (ACEs) to primary VLANs.

Cisco IOS dynamic ACL configuration applied to a primary VLAN is inactive while the VLAN is part of the PVLAN configuration.

To prevent spanning tree loops due to misconfigurations, enable PortFast on the PVLAN trunk ports with the spanning-tree portfast trunk command.

Any VLAN ACL configured on a secondary VLAN is effective in the input direction, and any VLAN ACL configured on the primary VLAN associated with the secondary VLAN is effective in the output direction.

You can stop Layer 3 switching on an isolated or community VLAN by deleting the mapping of that VLAN with its primary VLAN.

PVLAN ports can be on different network devices as long as the devices are trunk-connected and the primary and secondary VLANs remain associated with the trunk

Isolated ports on two different devices cannot communicate with each other, but community VLAN ports can.

Private VLANs support the following SPAN features:

You can configure a private VLAN port as a SPAN source port.

You can use VLAN-based SPAN (VSPAN) on primary, isolated, and community VLANs or use SPAN on only one VLAN to monitor egress or ingress traffic separately.

For more information about SPAN, see Chapter 46 "Configuring SPAN and RSPAN."

A primary VLAN can be associated with multiple community VLANs, but only one isolated VLAN.

An isolated or community VLAN can be associated with only one primary VLAN.

If you delete a VLAN used in a private VLAN configuration, the private VLAN ports associated with the VLAN become inactive.

VTP does not support private VLANs. You must configure private VLANs on each device in which you plan to use private VLAN ports.

To maintain the security of your PVLAN configuration and avoid other use of VLANs configured as PVLANs, configure PVLANs on all intermediate devices, even if the devices have no PVLAN ports.

Prune the PVLANs from trunks on devices that carry no traffic in the PVLANs.

With port ACLS functionality available, you can apply Cisco IOS ACLS to secondary VLAN ports and Cisco IOS ACLS to PVLANS (VACLs). For more information on VACLs, see Chapter 42 "Configuring Network Security with ACLs."

You can apply different quality of service (QoS) configurations to primary, isolated, and community VLANs. (See Chapter 33 "Configuring Quality of Service.") Cisco IOS ACLs applied to the Layer 3 VLAN interface of a primary VLAN automatically apply to the associated isolated and community VLANs.

On a PVLAN trunk port a secondary VLAN ACL is applied on ingress traffic and a primary VLAN ACL is applied on egress traffic.

On a promiscuous port the primary VLAN ACL is applied on ingress traffic.

Both PVLAN secondary and promiscuous trunk ports support only IEEE 802.1q encapsulation.

Community VLANs cannot be propagated or carried over private VLAN trunks.

ARP entries learned on Layer 3 PVLAN interfaces are termed "sticky" ARP entries (we recommend that you display and verify PVLAN interface ARP entries).

For security reasons, PVLAN port sticky ARP entries do not age out. Connecting a device with a different MAC address but with the same IP address generates an error message and the ARP entry is not created.

Because PVLAN port sticky ARP entries do not age out, you must manually remove the entries if you change the MAC address. To overwrite a sticky ARP entry, first delete the entry with the no arp command, then overwrite the entry with the arp command.

In a DHCP environment, if you shut down your PC, it is not possible to give your IP address to someone else. To solve this problem, the Catalyst 4500 series switch supports the no ip sticky-arp command. This command promotes IP address overwriting and reuse in a DHCP environment.

Normal VLANs can be carried on a promiscuous or isolated trunk port.

The default native VLAN for promiscuous trunk port is VLAN 1, the management VLAN. All untagged packets are forwarded in the native VLAN. Either the primary VLANs or a regular VLAN can be configured as native VLAN.

Promiscuous trunks cannot be configured to carry secondary VLANs. If a secondary VLAN is specified in the allowed VLAN list, the configuration is accepted but the port is not operational/forwarding in the secondary VLAN. This includes even those VLANs that are of scondary but not associated with any primary VLAN on given port.

On a promiscuous trunk port, the primary VLAN ACL and QoS are applied on ingress traffic coming in primary VLANs.

On a promiscuous trunk port, no VLAN ACL or QoS is applied to the egress traffic. This is because for upstream direction, traffic in private VLAN logically flows in the secondary VLAN. Due to VLAN translation in hardware, information about received secondary VLANs has been lost. Hence, no policies are applied. This restriction also applies to traffic bridged from other ports in the same primary VLANs.

Do not configure port security on PVLAN promiscuous trunk port and vice versa.

If port security is enabled on a promiscuous trunk port, that port may behave in an unpredictable manner because this functionality is not supported.

Do not configure IEEE 802.1X on a PVLAN promiscuous trunk port.


Note Community private VLAN trunk ports are not supported.


Configuring a VLAN as a PVLAN

To configure a VLAN as a PVLAN, perform this task:

 
Command
Purpose

Step 1 

Switch# configure terminal 

Enters configuration mode.

Step 2 

Switch(config)# vlan vlan_ID 

Enters VLAN configuration mode.

Step 3 

Switch(config-vlan)# private-vlan {community | 
isolated | primary}

Configures a VLAN as a PVLAN.

This command does not take effect until you exit VLAN configuration submode.

You can use the no keyword to clear PVLAN status.

Step 4 

Switch(config-vlan)# end 

Exits VLAN configuration mode.

Step 5 

Switch# show vlan private-vlan [type]

Verifies the configuration.

This example shows how to configure VLAN 202 as a primary VLAN and verify the configuration:

Switch# configure terminal 
Switch(config)# vlan 202 
Switch(config-vlan)# private-vlan primary 
Switch(config-vlan)# end 
Switch# show vlan private-vlan
Primary Secondary Type              Interfaces
------- --------- ----------------- ------------------------------------------
202               primary
 
   

This example shows how to configure VLAN 303 as a community VLAN and verify the configuration:

Switch# configure terminal 
Switch(config)# vlan 303 
Switch(config-vlan)# private-vlan community 
Switch(config-vlan)# end 
Switch# show vlan private-vlan 
 
   
Primary Secondary Type              Interfaces
------- --------- ----------------- ------------------------------------------
202               primary
        303       community 
 
   

This example shows how to configure VLAN 440 as an isolated VLAN and verify the configuration:

Switch# configure terminal 
Switch(config)# vlan 440 
Switch(config-vlan)# private-vlan isolated 
Switch(config-vlan)# end 
Switch# show vlan private-vlan 
 
   
Primary Secondary Type              Interfaces
------- --------- ----------------- ------------------------------------------
202               primary
        303       community 
        440       isolated 

Associating a Secondary VLAN with a Primary VLAN

To associate secondary VLANs with a primary VLAN, perform this task:

 
Command
Purpose

Step 1 

Switch# configure terminal 

Enters configuration mode.

Step 2 

Switch(config)# vlan primary_vlan_ID 

Enters VLAN configuration mode for the primary VLAN.

Step 3 

Switch(config-vlan)# private-vlan association 
{secondary_vlan_list | add secondary_vlan_list | 
remove secondary_vlan_list}

Associates the secondary VLAN with the primary VLAN. The list can contain only one isolated VLAN ID; it can also contain multiple community VLAN IDs.

You can use the no keyword to clear all secondary associations.

Step 4 

Switch(config-vlan)# end 

Exits VLAN configuration mode.

Step 5 

Switch# show vlan private-vlan [type] 

Verifies the configuration.

When you associate secondary VLANs with a primary VLAN, note the following:

The secondary_vlan_list parameter cannot contain spaces. It can contain multiple comma-separated items. Each item can be a single private VLAN ID or a hyphenated range of private VLAN IDs.

The secondary_vlan_list parameter can contain multiple community VLAN IDs.

The secondary_vlan_list parameter can contain only one isolated VLAN ID.

Enter a secondary_vlan_list or use the add keyword with a secondary_vlan_list to associate secondary VLANs with a primary VLAN.

Use the remove keyword with a secondary_vlan_list to clear the association between secondary VLANs and a primary VLAN.

The command does not take effect until you exit VLAN configuration submode.

This example shows how to associate community VLANs 303 through 307 and 309 and isolated VLAN 440 with primary VLAN 202 and verify the configuration:

Switch# configure terminal 
Switch(config)# vlan 202 
Switch(config-vlan)# private-vlan association 303-307,309,440 
Switch(config-vlan)# end 
Switch# show vlan private-vlan 
 
   
Primary Secondary Type              Interfaces
------- --------- ----------------- ------------------------------------------
202     303       community 
202     304       community 
202     305       community 
202     306       community 
202     307       community 
202     309       community 
202     440       isolated 
        308       community 

Note The secondary VLAN 308 has no associated primary VLAN.


Configuring a Layer 2 Interface as a PVLAN Promiscuous Port

To configure a Layer 2 interface as a PVLAN promiscuous port, perform this task:

 
Command
Purpose

Step 1 

Switch# configure terminal 

Enters global configuration mode.

Step 2 

Switch(config)# interface {fastethernet | 
gigabitethernet | tengigabitethernet} slot/port 

Specifies the LAN interface to configure.

Step 3 

Switch(config-if)# switchport mode private-vlan 
{host | promiscuous | trunk promiscuous | trunk 
[secondary]}

Configures a Layer 2 interface as a PVLAN promiscuous port.

Step 4 

Switch(config-if)# [no] switchport private-vlan 
mapping [trunk] primary_vlan_ID 
{secondary_vlan_list | add secondary_vlan_list | 
remove secondary_vlan_list}

Maps the PVLAN promiscuous port to a primary VLAN and to selected secondary VLANs.

Step 5 

Switch(config-if)# end 

Exits configuration mode.

Step 6 

Switch# show interfaces {fastethernet | 
gigabitethernet | tengigabitethernet} slot/port 
switchport 

Verifies the configuration.


Note The maximum number of unique PVLAN pairs supported by the switchport private-vlan mapping command is 1000.


When you configure a Layer 2 interface as a PVLAN promiscuous port, note the following:

The secondary_vlan_list parameter cannot contain spaces. It can contain multiple comma-separated items. Each item can be a single PVLAN ID or a hyphenated range of PVLAN IDs.

Enter a secondary_vlan_list or use the add keyword with a secondary_vlan_list to map the secondary VLANs to the PVLAN promiscuous port.

Use the remove keyword with a secondary_vlan_list to clear the mapping between secondary VLANs and the PVLAN promiscuous port.

This example shows how to configure interface FastEthernet 5/2 as a PVLAN promiscuous port, map it to a PVLAN, and verify the configuration:

Switch# configure terminal 
Switch(config)# interface fastethernet 5/2 
Switch(config-if)# switchport mode private-vlan promiscuous 
Switch(config-if)# switchport private-vlan mapping 200 2
Switch(config-if)# end 
Switch# show interfaces fastethernet 5/2 switchport
Name:Fa5/2
Switchport:Enabled
Administrative Mode:private-vlan promiscuous
Operational Mode:private-vlan promiscuous
Administrative Trunking Encapsulation:negotiate
Operational Trunking Encapsulation:native
Negotiation of Trunking:Off
Access Mode VLAN:1 (default)
Trunking Native Mode VLAN:1 (default)
Voice VLAN:none
Administrative Private VLAN Host Association:none
Administrative Private VLAN Promiscuous Mapping:200 (VLAN0200) 2 (VLAN0002)
Private VLAN Trunk Native VLAN:none
Administrative Private VLAN Trunk Encapsulation:dot1q
Administrative Private VLAN Trunk Normal VLANs:none
Administrative Private VLAN Trunk Private VLANs:none
Operational Private VLANs:
  200 (VLAN0200) 2 (VLAN0002)
Trunking VLANs Enabled:ALL
Pruning VLANs Enabled:2-1001
Capture Mode Disabled
Capture VLANs Allowed:ALL

Configuring a Layer 2 Interface as a PVLAN Host Port

To configure a Layer 2 interface as a PVLAN host port, perform this task:

 
Command
Purpose

Step 1 

Switch# configure terminal 

Enters configuration mode.

Step 2 

Switch(config)# interface {fastethernet | 
gigabitethernet | tengigabitethernet} slot/port 

Specifies the LAN port to configure.

Step 3 

Switch(config-if)# switchport mode private-vlan 
{host | promiscuous | trunk promiscuous | trunk 
[secondary]}

Configures a Layer 2 interface as a PVLAN host port.

Step 4 

Switch(config-if)# [no] switchport private-vlan 
host-association primary_vlan_ID 
secondary_vlan_ID 

Associates the Layer 2 interface with a PVLAN.

You can use the no keyword to delete all associations from the primary VLAN.

Step 5 

Switch(config-if)# end 

Exits configuration mode.

Step 6 

Switch# show interfaces {fastethernet | 
gigabitethernet | tengigabitethernet} slot/port 
switchport 

Verifies the configuration.

This example shows how to configure interface FastEthernet 5/1 as a PVLAN host port and verify the configuration:

Switch# configure terminal 
Switch(config)# interface fastethernet 5/1 
Switch(config-if)# switchport mode private-vlan host 
Switch(config-if)# switchport private-vlan host-association 202 440

Switch(config-if)# end

Switch# show interfaces fastethernet 5/1 switchport
Name: Fa5/1
Switchport: Enabled
Administrative Mode: private-vlan host
Operational Mode: private-vlan host
Administrative Trunking Encapsulation: negotiate
Operational Trunking Encapsulation: native
Negotiation of Trunking: Off
Access Mode VLAN: 1 (default)
Trunking Native Mode VLAN: 1 (default)
Voice VLAN: none
Appliance trust: none
Administrative Private Vlan 
  Host Association: 202 (VLAN0202) 440 (VLAN0440)
  Promiscuous Mapping: none 
  Trunk encapsulation : dot1q
  Trunk vlans:
Operational private-vlan(s): 
  202 (VLAN0202) 440 (VLAN0440) 
Trunking VLANs Enabled: ALL
Pruning VLANs Enabled: 2-1001
Capture Mode Disabled
Capture VLANs Allowed: ALL

Configuring a Layer 2 Interface as an Isolated PVLAN Trunk Port

To configure a Layer 2 interface as an isolated PVLAN trunk port, perform this task:

 
Command
Purpose

Step 1 

Switch# configure terminal
Enters global configuration mode.

Step 2 

Switch(config)# interface {fastethernet | 
gigabitethernet | tengigabitethernet} slot/port 
Specifies the LAN port to configure.

Step 3 

Switch(config-if)# switchport mode private-vlan 
{host | promiscuous | trunk promiscuous | trunk 
[secondary]}

Configures a Layer 2 interface as a PVLAN trunk port.

Step 4 

Switch(config-if)# [no] switchport private-vlan 
association trunk primary_vlan_ID 
secondary_vlan_ID 

Configures association between primary VLANs and secondary VLANs the PVLAN trunk port with a PVLAN.

Note Multiple PVLAN pairs can be specified using this command so that a PVLAN trunk port can carry multiple secondary VLANs. If an association is specified for the existing primary VLAN, the existing association is replaced. If there is no trunk association, any packets received on secondary VLANs are dropped.

You can use the no keyword to delete all associations from the primary VLAN.

Step 5 

Switch(config-if)# [no] switchport private-vlan 
trunk allowed vlan vlan_list all | none | [add | 
remove | except] vlan_atom[,vlan_atom...]

Configures a list of allowed normal VLANs on a PVLAN trunk port.

You can use the no keyword to remove all allowed normal VLANs on a PVLAN trunk port.

Step 6 

Switch(config-if)# switchport private-vlan trunk 
native vlan vlan_id

Configures a VLAN to which untagged packets (as in IEEE 802.1Q tagging) are assigned on a PVLAN trunk port.

If there is no native VLAN configured, all untagged packets are dropped.

If the native VLAN is a secondary VLAN and the port does not have the association for the secondary VLAN, the untagged packets are dropped.

You can use the no keyword to remove all native 
VLANs on a PVLAN trunk port.

Step 7 

Switch(config-if)# end
Exits configuration mode.

Step 8 

Switch# show interfaces {fastethernet | 
gigabitethernet | tengigabitethernet} slot/port 
switchport 
Verifies the configuration.

This example shows how to configure interface FastEthernet 5/2 as a secondary trunk port, and verify the configuration:

Switch# configure terminal 
Switch(config)# interface fastethernet 5/2 
Switch(config-if)# switchport mode private-vlan trunk secondary
Switch(config-if)# switchport private-vlan trunk native vlan 10
Switch(config-if)# switchport private-vlan trunk allowed vlan 10. 3-4
Switch(config-if)# switchport private-vlan association trunk 3 301
Switch(config-if)# end 
Switch# show interfaces fastethernet 5/2 switchport
Name: Fa5/2
Switchport: Enabled
Administrative Mode: private-vlan trunk secondary 
Operational Mode: private-vlan trunk secondary 
Administrative Trunking Encapsulation: negotiate 
Operational Trunking Encapsulation: dot1q 
Negotiation of Trunking: On 
Access Mode VLAN: 1 (default) 
Trunking Native Mode VLAN: 1 (default) 
Administrative Native VLAN tagging: enabled 
Voice VLAN: none 
Administrative private-vlan host-association: none A
dministrative private-vlan mapping: none 
Administrative private-vlan trunk native VLAN: 10 
Administrative private-vlan trunk Native VLAN tagging: enabled 
Administrative private-vlan trunk encapsulation: dot1q 
Administrative private-vlan trunk normal VLANs: none 
Administrative private-vlan trunk associations: 
    3 (VLAN0003) 301 (VLAN0301)
Administrative private-vlan trunk mappings: none 
Operational private-vlan: none 
Operational Normal VLANs: none 
Trunking VLANs Enabled: ALL 
Pruning VLANs Enabled: 2-1001 
Capture Mode Disabled Capture VLANs Allowed: ALL
 
   
Unknown unicast blocked: disabled
Unknown multicast blocked: disabled
Appliance trust: none

Configuring a Layer 2 Interface as a Promiscuous PVLAN Trunk Port

To configure a Layer 2 interface as a promiscuous PVLAN trunk port, perform this task:

 
Command
Purpose

Step 1 

Switch# configure terminal 

Enters global configuration mode.

Step 2 

Switch(config)# interface {fastethernet | 
gigabitethernet | tengigabitethernet} slot/port 

Specifies the LAN interface to configure.

Step 3 

Switch(config-if)# switchport mode private-vlan {host 
| promiscuous | trunk promiscuous | trunk [secondary]}

Configures a Layer 2 interface as a PVLAN promiscuous trunk port.

Step 4 

Switch(config-if)# [no] switchport private-vlan 
mapping [trunk] primary_vlan_ID {secondary_vlan_list | 
add secondary_vlan_list | remove secondary_vlan_list}

Maps the promiscuous PVLAN port to a primary VLAN and to selected secondary VLANs.

This command offers 3 levels of removal. See the examples that follow this table.

Step 5 

Switch(config-if)# end 

Exits configuration mode.

Step 6 

Switch# show interfaces {fastethernet | 
gigabitethernet | tengigabitethernet} slot/port 
switchport 

Verifies the configuration.


Note The maximum number of unique PVLAN pairs supported by the
switchport private-vlan mapping trunk
command is 500. For example, 500 isolated secondary VLANs could map to 500 primary VLANs, because only one isolated VLAN association per primary VLAN is supported. Or, 500 community secondary VLANs could map to one primary VLAN. Or, 250 community secondary VLANs could map to 1 primary VLAN, and another 250 community secondary VLANs could map to another primary VLAN for a total of 500 pairs.



Note By default, when you configure the mode to private VLAN trunk promiscuous, the native VLAN is set to 1.


The [no] switchport private-vlan mapping command provides the following three levels of removal:

Remove one or more secondary VLANs from the list. For example:

Switch(config-if)# switchport private-vlan mapping trunk 2 remove 222
 
   

Remove the entire mapping of PVLAN promiscuous trunk port to the specified primary VLAN (and all of its selected secondary VLANs). For example:

Switch(config-if)# no switchport private-vlan mapping trunk 2
 
   

Remove the mapping of a PVLAN promiscuous trunk port to all previously configured primary VLANs (and all of their selected secondary VLANs). For example:

Switch(config-if)# no switchport private-vlan mapping trunk
 
   

When you configure a Layer 2 interface as a PVLAN promiscuous port, note the following:

Multiple private VLAN pairs can be specified using the switchport private-vlan mapping trunk command so that a promiscuous trunk port can carry multiple primary VLANs.

The secondary_vlan_list parameter cannot contain spaces. It can contain multiple comma-separated items. Each item can be a single PVLAN ID or a hyphenated range of PVLAN IDs.

Enter a secondary_vlan_list or use the add keyword with a secondary_vlan_list to map the secondary VLANs to the PVLAN promiscuous port.

Use the remove keyword with a secondary_vlan_list to clear the mapping between secondary VLANs and the PVLAN promiscuous port.

This example shows how to configure interface FastEthernet 5/2 as a promiscuous trunk port and to verify the configuration:

Switch# configure terminal 
Switch(config)# interface fastethernet 5/2 
Switch(config-if)# switchport mode private-vlan trunk promiscuous
Switch(config-if)# switchport private-vlan trunk native vlan 10
Switch(config-if)# switchport private-vlan trunk allowed vlan 10, 3-4
Switch(config-if)# switchport private-vlan mapping trunk 3 301, 302
Switch(config-if)# end 
Switch# show interfaces fastethernet 5/2 switchport
Name: Fa5/2
Switchport: Enabled
Administrative Mode: private-vlan trunk promiscuous 
Operational Mode: private-vlan trunk promiscuous 
Administrative Trunking Encapsulation: negotiate 
Operational Trunking Encapsulation: dot1q 
Negotiation of Trunking: On 
Access Mode VLAN: 1 (default) 
Trunking Native Mode VLAN: 1 (default) 
Administrative Native VLAN tagging: enabled 
Voice VLAN: none 
Administrative private-vlan host-association: none 
Administrative private-vlan mapping: none 
Administrative private-vlan trunk native VLAN: 10 
Administrative private-vlan trunk Native VLAN tagging: enabled 
Administrative private-vlan trunk encapsulation: dot1q 
Administrative private-vlan trunk normal VLANs: 3-4,10 
Administrative private-vlan trunk associations: none 
Administrative private-vlan trunk mappings: 
    3 (VLAN0003) 301 (VLAN0301)  302 (VLAN0302) 
Operational private-vlan: 
  3 (VLAN0003) 301 (VLAN0301) 302 (VLAN0302) 
Trunking VLANs Enabled: ALL 
Pruning VLANs Enabled: 2-1001 
Capture Mode Disabled 
Capture VLANs Allowed: ALL
 
   
Unknown unicast blocked: disabled
Unknown multicast blocked: disabled
Appliance trust: none

Permitting Routing of Secondary VLAN Ingress Traffic


Note Isolated and community VLANs are both called secondary VLANs.


To permit routing of secondary VLAN ingress traffic, perform this task:

 
Command
Purpose

Step 1 

Switch# configure terminal 

Enters global configuration mode.

Step 2 

Switch(config)# interface vlan primary_vlan_ID 

Enters interface configuration mode for the primary VLAN.

Step 3 

Switch(config-if)# [no] private-vlan mapping 
primary_vlan_ID {secondary_vlan_list | add 
secondary_vlan_list | remove secondary_vlan_list}

To permit routing on the secondary VLAN ingress traffic, map the secondary VLAN to the primary VLAN.

You can use the no keyword to delete all associations from the primary VLAN.

Step 4 

Switch(config-if)# end 

Exits configuration mode.

Step 5 

Switch# show interface private-vlan mapping

Verifies the configuration.

When you permit routing on the secondary VLAN ingress traffic, note the following:

The private-vlan mapping interface configuration command only affects private VLAN ingress traffic that is Layer 3 switched.

The secondary_vlan_list parameter cannot contain spaces. It can contain multiple comma-separated items. Each item can be a single private VLAN ID or a hyphenated range of private VLAN IDs.

Enter a secondary_vlan_list parameter or use the add keyword with a secondary_vlan_list parameter to map the secondary VLANs to the primary VLAN.

Use the remove keyword with a secondary_vlan_list parameter to clear the mapping between secondary VLANs and the primary VLAN.

This example shows how to permit routing of secondary VLAN ingress traffic from private VLANs 303 through 307, 309, and 440 and verify the configuration:

Switch# configure terminal 
Switch(config)# interface vlan 202 
Switch(config-if)# private-vlan mapping add 303-307,309,440 
Switch(config-if)# end 
Switch# show interfaces private-vlan mapping 
Interface Secondary VLAN Type
--------- -------------- -----------------
vlan202   303            community
vlan202   304            community
vlan202   305            community
vlan202   306            community
vlan202   307            community
vlan202   309            community
vlan202   440            isolated
 
   
Switch#