- Configuring ATM
- AAL1 CES on AIM-ATM
- DHCP Client on WAN Interfaces
- Lossless Compression and ATM Cell Switching and BITS Clocking
- ATM Multilink PPP Support on Multiple VCs
- ATM OAM Support for F5 Continuity Check
- ATM OAM Ping
- ATM Policing by Service Category for SVC SoftPVC
- Configuring ATM SNMP Trap and OAM Enhancements
- ATM SVC Troubleshooting Enhancements
- ATM Software Segmentation and Reassembly
- Unspecified Bit Rate Plus and ATM Enhancements
- Enhanced Voice and QoS for ADSL and G.SHDSL
- End of Life for Multiprotocol over ATM
- Multiprotocol over ATM Overview
- Configuring the Multiprotocol over ATM Client
- Configuring the Multiprotocol over ATM Server
- Configuring Token Ring LAN Emulation MPOA
- MPLS Diff-Serv-aware Traffic Engineering over ATM
- End of Life for LAN Emulation
- LAN Emulation Overview
- Configuring LAN Emulation
- Configuring Token Ring LAN Emulation
- SNMP Trap Support for the Virtual Switch Interface Master MIB
- VLAN 0 Priority Tagging Support
- Preserve 802.1Q Tagging with 802.1P Marking over ATM PVCs for xDSL Uplinks
- Reuse MAC for ATM Route-Bridge Encapsulation
- Index
Configuring the Multiprotocol over ATM Client
The Multiprotocol over ATM (MPOA) client (MPC) involves ingress/egress cache management, data-plane and control-plane virtual circuit connection (VCC) management, MPOA frame processing, and participation in MPOA protocol and MPOA flow detection.
- Finding Feature Information
- Information About the Multiprotocol over ATM Client
- How to Configure the Multiprotocol over ATM Client
- Configuration Examples for the Multiprotocol over ATM Client
- Additional References
- Feature Information for the Multiprotocol over ATM Client
Finding Feature Information
Your software release may not support all the features documented in this module. For the latest caveats and feature information, see Bug Search Tool and the release notes for your platform and software release. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the feature information table.
Use Cisco Feature Navigator to find information about platform support and Cisco software image support. To access Cisco Feature Navigator, go to www.cisco.com/go/cfn. An account on Cisco.com is not required.
Information About the Multiprotocol over ATM Client
MPC Software Module
The MPC software module implements the functionality of the MPC in compliance with the ATM Forum MPOA specification. An MPC identifies packets sent to an MPOA-capable router over the nonbroadcast multi-access (NBMA) network and establishes a shortcut VCC to the egress MPC, if possible. The MPC then routes these packets directly over this shortcut VCC, bypassing the intermediate routers and enabling the fast routing of internetwork-layer packets across an NBMA network. The Catalyst 5000 series switch can be designated as an MPC. If the Catalyst 5000 series switch is configured with an RSM/VIP2 (with an ATM interface) it can be configured as an MPC or an MPS.
A router is usually designated as an MPOA server (MPS), but can also be designated as an MPC. MPC on the router is primarily meant to provide router-initiated and router-terminated shortcuts for non-NBMA networks. For this reason, MPC information in this chapter primarily refers to the Catalyst 5000 series switch, and MPS information refers to the router or the RSM/VIP2 with an ATM interface in a Catalyst 5000 series switch.
How to Configure the Multiprotocol over ATM Client
- Configuring the ELAN ID
- Configuring the MPC
- Configuring the MPC Variables
- Monitoring and Maintaining the MPC
Configuring the ELAN ID
For MPOA to work properly, an LEC must belong to an ELAN that has a defined ELAN ID.
Caution | If an ELAN ID is supplied, make sure both commands use the same elan-id value. |
To obtain an ELAN ID, use either of the following commands in LANE database configuration mode.
Note | To configure an MPC on a Catalyst 5000 series ATM module, establish a connection with the ATM module, enter privileged mode, and then enter configuration mode. For information on performing these tasks, refer to the Catalyst 5000 Series Software Configuration Guide . |
Command or Action |
Purpose |
---|---|
Router(lane-config-dat)# name elan-name elan-id id |
Defines an ELAN ID for the LEC (in LANE database configuration mode). |
Router(lane-config-dat)# lane server-bus ethernet elan-name [elan-id id ] |
Configures the LEC with the ELAN ID (in interface configuration mode). |
Configuring the MPC
To configure an MPC on your network, perform the steps in this section.
1. Router(config)# mpoa client config namempc-name
2. Router(config-if)# interface atm {mod-num/port-num | number }
3. Router(config-if)# mpoa client namempc-name
4. Router(config-if)# interfaceatm-num.sub-interface-num
5. Router(config-if)# lane client mpoa client namempc-name
6. Repeat Steps 4 and 5 for every LEC to be served by the MPC/MPS.
DETAILED STEPS
Command or Action | Purpose | |
---|---|---|
Step 1 | Router(config)# mpoa client config namempc-name |
In global configuration mode, defines an MPC with a specified name. |
Step 2 | Router(config-if)# interface atm {mod-num/port-num | number } |
In interface configuration mode, specifies the ATM interface to which the MPC is associated. |
Step 3 | Router(config-if)# mpoa client namempc-name |
In interface configuration mode, attaches an MPC to the ATM interface. |
Step 4 | Router(config-if)# interfaceatm-num.sub-interface-num |
In interface configuration mode, specifies the ATM interface that contains the LEC to which you will bind the MPC. |
Step 5 | Router(config-if)# lane client mpoa client namempc-name |
In interface configuration mode, binds a LEC to the specified MPC. |
Step 6 | Repeat Steps 4 and 5 for every LEC to be served by the MPC/MPS. |
|
Configuring the MPC Variables
An MPC has to be defined with a specified name before you can change its variables.
To change the variables for an MPC, perform the steps in this section.
1. Router(mpoa-client-config)# mpoa client config namemps-name
2. Router(mpoa-client-config)# atm-addressatm-address
3. Router(mpoa-client-config)# shortcut-frame-countcount
4. Router(mpoa-client-config)# shortcut-frame-timetime
DETAILED STEPS
Command or Action | Purpose | |
---|---|---|
Step 1 | Router(mpoa-client-config)# mpoa client config namemps-name |
Defines an MPC with the specified name. |
Step 2 | Router(mpoa-client-config)# atm-addressatm-address |
(Optional) Specifies the control ATM address that the MPC should use (when it is associated with a hardware interface). |
Step 3 | Router(mpoa-client-config)# shortcut-frame-countcount |
(Optional) Specifies the maximum number of times a packet can be routed to the default router within shortcut-frame time before an MPOA resolution request is sent. |
Step 4 | Router(mpoa-client-config)# shortcut-frame-timetime |
(Optional) Sets the shortcut-setup frame time for the MPC. |
Monitoring and Maintaining the MPC
To monitor and maintain the configuration of an MPC, use the following commands as needed.
1. Router# show mpoa client [namempc-name ]
2. Router# show mpoa client [namempc-name ] cache [ingress | egress] [ip-addrip-addr ]
3. Router# show mpoa client [namempc-name ] statistics
4. Router# clear mpoa client [namempc-name ] cache [ingress | egress] [ip-addrip-addr ]
5. Router# show mpoa client [namempc-name ] [remote-device ]
6. Router# show mpoa default-atm-addresses
DETAILED STEPS
Command or Action | Purpose | |
---|---|---|
Step 1 | Router# show mpoa client [namempc-name ] |
Displays information about a specified MPC or all MPCs. |
Step 2 | Router# show mpoa client [namempc-name ] cache [ingress | egress] [ip-addrip-addr ] |
Displays ingress and egress cache entries associated with an MPC. |
Step 3 | Router# show mpoa client [namempc-name ] statistics |
Displays all the statistics collected by an MPC. |
Step 4 | Router# clear mpoa client [namempc-name ] cache [ingress | egress] [ip-addrip-addr ] |
Clears cache entries. |
Step 5 | Router# show mpoa client [namempc-name ] [remote-device ] |
Displays all the MPOA devices that this MPC has learned. |
Step 6 | Router# show mpoa default-atm-addresses |
Displays the default ATM addresses for the MPC. |
Configuration Examples for the Multiprotocol over ATM Client
Configuring MCP Example
This section contains an example of the commands needed to configure an MPC. The lines beginning with exclamation points (!) are comments explaining the command shown on the subsequent line. The figure below shows an example of how you can configure your system to use MPOA.
The following example shows how to configure the MPC and attach the MPC to a hardware interface:
! Define the MPC "MYMPC" mpoa client config name MYMPC ! Leave everything as default exit ! Specify the ATM interface to which the MPC is attached interface ATM 1/0 ! Attach MPC MYMPC to the HW interface mpoa client name MYMPC ! Specify the ATM interface that contains the LEC to which you will bind the MPC interface atm 1/0.1 ! Bind a LANE client to the specified MPC lane client mpoa client name MYMPC ! Go back up to global config mode exit
The following example shows a typical configuration file for the first MPC:
Current configuration: ! version 11.3 ! Go to LANE database config mode exit lane database mpoa-test hostname mpc-1 ! Define the ELAN ID and ATM address name elan1 server-atm-address 47.00918100000000613E5A2F01.006070174821.01 name elan1 elan-id 101 name elan2 server-atm-address 47.00918100000000613E5A2F01.006070174821.02 name elan2 elan-id 102 ! Define the MPC "mpc-1" mpoa client config name mpc-1 interface Ethernet0 ! Go back up to global config mode exit ! Specify the ATM interface to which the MPC is attached interface ATM0 atm pvc 1 0 5 qsaal atm pvc 2 0 16 ilmi lane config auto-config-atm-address lane config database mpoa-test ! Attach MPC mpc-1 to the HW interface mpoa client name mpc-1 ! Specify the ATM interface that contains the LEC to which you will bind the MPC interface ATM0.1 multipoint lane server-bus ethernet elan1 ! Bind a LANE client to the specified MPC lane client mpoa client name mpc-1 lane client ethernet 1 elan1 ! Go back up to global config mode exit
The following example shows a typical configuration file for the second MPC:
Current configuration: ! version 11.3 hostname mpc-2 ! Go back up to global config mode exit ! Define the MPC "mpc-2" mpoa client config name mpc-2 ! Specify the ATM interface to which the MPC is attached interface ATM0 atm pvc 1 0 5 qsaal atm pvc 2 0 16 ilmi mpoa client name mpc-2 ! Specify the ATM interface that contains the LEC to which you will bind the MPC interface ATM0.1 multipoint lane server-bus ethernet elan2 lane client mpoa client name mpc-2 lane client ethernet 2 elan2 ! Go back up to global config mode exit
Additional References
Related Documents
Related Topic |
Document Title |
---|---|
Cisco IOS commands |
|
ATM commands |
Cisco IOS Asynchronous Transfer Mode Command Reference |
Standards
Standard |
Title |
---|---|
None |
|
MIBs
MIB |
MIBs Link |
---|---|
None |
To locate and download MIBs for selected platforms, Cisco software releases, and feature sets, use Cisco MIB Locator found at the following URL: |
RFCs
RFC |
Title |
---|---|
None |
|
Technical Assistance
Description |
Link |
---|---|
The Cisco Support website provides extensive online resources, including documentation and tools for troubleshooting and resolving technical issues with Cisco products and technologies. To receive security and technical information about your products, you can subscribe to various services, such as the Product Alert Tool (accessed from Field Notices), the Cisco Technical Services Newsletter, and Really Simple Syndication (RSS) Feeds. Access to most tools on the Cisco Support website requires a Cisco.com user ID and password. |
Feature Information for the Multiprotocol over ATM Client
The following table provides release information about the feature or features described in this module. This table lists only the software release that introduced support for a given feature in a given software release train. Unless noted otherwise, subsequent releases of that software release train also support that feature.
Use Cisco Feature Navigator to find information about platform support and Cisco software image support. To access Cisco Feature Navigator, go to . An account on Cisco.com is not required.
Feature Name |
Releases |
Feature Information |
---|---|---|
Multiprotocol over ATM Client |
12.0(1) 12.1(1)E |
The Multiprotocol over ATM (MPOA) client (MPC) involves ingress/egress cache management, data-plane and control-plane virtual circuit connection (VCC) management, MPOA frame processing, and participation in MPOA protocol and MPOA flow detection. The following commands were introduced or modifief: clear mpoa client cache, debug mpoa client, lane client mpoa client name, mpoa client config name, mpoa client name, show mpoa client, show mpoa client cache, show mpoa client statistics. |