To help control the size of user voice mailboxes, you can use Cisco Unity Connection Administration to specify mailbox size quotas. Cisco Unity Connection is set up with the following system-wide default mailbox size quotas, which you can modify:
•Warning Quota—When a user mailbox reaches the size specified in the warning quota, the user is warned that the mailbox is reaching the maximum size allowed.
The system-wide default Warning Quota is 12,000,000 bytes. This translates to approximately 200 minutes of recording with the G729a codec, and approximately 25 minutes of recording with the G711 codec.
•Send Quota—When the mailbox reaches the size specified in the send quota, the user is prevented from sending any more voice messages.
The system-wide default Send Quota is 13,000,000 bytes. This translates to approximately 217 minutes of recording with the G729a codec, and approximately 27 minutes of recording with the G711 codec.
•Send/Receive Quota—When the mailbox reaches the size specified in the send/receive quota field, the user is prevented from sending or receiving any more voice messages.
The system-wide default Send/Receive Quota is 14,745,600 bytes. This translates to approximately 245 minutes of recording with the G729a codec, and approximately 30 minutes of recording with the G711 codec.
You can also configure per-user custom quotas that override the system-level quotas. The custom quotas can be configured in a user template, and can be modified on individual user accounts.
For procedural information, see the "Mailbox Size Quotas" section in the "Setting Up Features and Functionality That Are Controlled by User Account Settings" chapter of the User Moves, Adds, and Changes Guide for Cisco Unity Connection. The guide is available at http://www.cisco.com/en/US/products/ps6509/prod_maintenance_guides_list.html.