show hardware

This chapter includes the show hardware command output tables.


Important


The nomenclature appearing in the outputs of show hardware commands vary based on platform (VPC, ASR 5000, ASR 5500), card type, date of manufacture, and the StarOS release.


show hardware (VPC-DI)

In a VPC-DI instance, card numbers correspond to the virtual slot numbers assigned to the virtual machines (VMs) that run StarOS within the virtual chassis created by hypervisor templates.

Table 1. show hardware Command Output Descriptions (VPC-DI)
Field Description

Control Function and Service Function Cards

Card <number>

Virtual slot number of the specified card. Slots 1 and 2 = CF; Slots 3 – 48 = SF.

Card Type

Control Function Virtual Card or 1-Port Service Function Virtual Card.

CPU Packages

Number of vCPUs.

CPU nodes

Number of CPU nodes.

CPU Cores/Threads

Number of cores/threads.

Memory

vMemory in Megabytes

Platform

Hypervisor type.

CFE/Diags

Common Firmware Environment/Diagnostic firmware.

Network Interfaces

cpeth0

VPC-DI network communication port.

  Address

MAC address.

  Device

Device type.

  ID

VPC-DI identifier (hexadecimal).

  Driver

Driver type.

  RxQ(s)/RINGSZ/COALESCE

Receive queue information from hypervisor.

  TxQ(s)/RINGSZ/COALESCE

Transmit queue information from hypervisor.

loeth0

CF only: LOCAL management port (Console).

  Address

MAC address.

  Device

Device type.

  ID

VPC-DI identifier (hexadecimal).

  Driver

Driver type.

  RxQ(s)/RINGSZ/COALESCE

Receive queue information from hypervisor.

  TxQ(s)/RINGSZ/COALESCE

Transmit queue information from hypervisor.

port_slot_port

SF only: Service port.

  Address

MAC address.

  Device

Device type.

  ID

VPC-DI identifier (hexadecimal).

  Driver

Driver type. (alphanumeric string)

  RxQ(s)/RINGSZ/COALESCE

Receive queue information from hypervisor.

  TxQ(s)/RINGSZ/COALESCE

Transmit queue information from hypervisor.

Storage Devices

Virtual Flash

Indicates whether or not the virtual /flash drive is Present.

   Type

Virtual drive type (alphanumeric string).

   Model

Virtual drive model (alphanumeric string).

Hard Drive 1

Indicates whether virtual Hard Drive 1 is Present.

   Type

Virtual drive type (alphanumeric string).

   Model

Virtual drive model (alphanumeric string).

Hard Drive 2

Indicates whether virtual Hard Drive 2 is Present.

USB 1

Indicates whether virtual USB port 1 is Present (must be configured via hypervisor).

USB 2

Indicates whether virtual USB port 2 is Present (must be configured via hypervisor).

CDROM 1

Indicates whether virtual a CDROM is Present (must be configured via hypervisor).

   Type

CDROM drive type (alphanumeric string).

   Model

CDROM drive model (alphanumeric string).

Card Programmables

Indicates if the software on any of the programmable components on the card is not at the current revision.

"up to date" – all software is current

"out of date" – identifies one or more components do not have the most current software.

"experimental/unreleased" – one or more components have experimental or unreleased software.

show hardware (VPC-SI)

For VPC-SI, the output of this command displays the parameters of the virtual chassis created by the hypervisor in which the StarOS VM runs.

Table 2. show hardware Command Output Descriptions (VPC-SI)
Field Description

System information

Platform

Hypervisor type.

UUID/Serial Number

Cisco serial number

CPU Packages

Number of vCPUs.

CPU nodes

Number of CPU nodes.

CPU Cores/Threads

Number of cores/threads.

Memory

vMemory in Megabytes

Storage Devices

Virtual Flash

Indicates whether or not the virtual /flash drive is Present.

   Type

Virtual drive type (alphanumeric string).

   Model

Virtual drive model (alphanumeric string).

Hard Drive 1

Indicates whether virtual Hard Drive 1 is Present.

   Type

Virtual drive type (alphanumeric string).

   Model

Virtual drive model (alphanumeric string).

Hard Drive 2

Indicates whether virtual Hard Drive 2 is Present.

USB 1

Indicates whether virtual USB port 1 is Present (must be configured via hypervisor).

USB 2

Indicates whether virtual USB port 2 is Present (must be configured via hypervisor).

CDROM 1

Indicates whether virtual a CDROM is Present (must be configured via hypervisor).

   Type

CDROM drive type (alphanumeric string).

   Model

CDROM drive model (alphanumeric string).

Network Interfaces

loeth0

LOCAL management port IP address and port type.

port1_<10 through 21>

Traffic management port IP address and port type in parentheses.

show hardware card (ASR 5000)

Table 3. show hardware card Command Output Descriptions (ASR 5000)
Field Description

Common to All Card Types

Card <number>

Slot number of the specified card.

Card Type

Description of the card in the specified slot, for example "System Management Card".

Card Description

SMC, PSCx, FELC, GELC/GLC2, QGLC, XGLC, CLC/CLC2, OLC/OLC2, SPIO, RCC

Part Number

Legacy part number (xxx-xx-xxxx xx).

Serial Number

Legacy part number (alphanumeric string).

CLEI Code, Starent CLEI Code

Common Language Equipment Identifier (CLEI) code.

UDI Product ID

Unique Device Identifier (UDI) Product Identifier (PID).

UDI Version ID

UDI version.

UDI Serial Number

UDI serial number (alphanumeric string).

UDI CLEI Code

UDI Common Language Equipment Identifier (CLEI) code.

UDI Top Assembly Number

UDI for top-level assembly.

UDI TAN Revision

UDI Top Assembly Number (TAN) revision level.

UDI Deviation Number

UDI deviation number (DEVNUM).

MAC Addresses

Media Access Controller hexadecimal starting address in format: xx-xx-xx-xx-xx-xx.

Switch Fabric Modes

Mode type – "control plane" and/or "switch fabric".

Card Programmables

Indicates if the software on any of the programmable components on the card is not at the current revision.

"up to date" – all software is current

"out of date" – identifies one or more components do not have the most current software.

"experimental/unreleased" – one or more components have experimental or unreleased software.

System Management Card

Compact Flash

Status of PCMCIA flash memory card, for example "Present".

   Type

Memory capacity of the Compact Flash card.

   Model

Operational card type.

  Serial Number

Serial number of this Compact Flash card.

PCMCIA1

Status of front panel Personal Computer Memory Card International Association (PCMCIA) card, for example "Not Present".

Hard Drive 1

Status of this hard drive, for example "Present".

   Type

Drive capacity in Mbytes.

  Model

Manufacturer and model number.

  Serial Number

Serial number of the hard drive.

SRM

Status, Reset, and Monitoring firmware.

BIOS

Basic Input/Output System.

CIF FPGA

Chassis Information (CIF) Field Programmable Gate Array (FPGA) firmware.

CPU 0 Type/Memory

Socket: 0: <processor type>, <processor speed>: Chipset: <chipset_type>, <part_number>, <RAM>

CPU 0 DIMM-A1 P/N

Dual In-line Memory Module part number.

CPU 0 DIMM-B1 P/N

Dual In-line Memory Module part number.

CPU 0 CFE/Diags

Common Firmware Environment/Diagnostic firmware.

Packet Processing Card (PSC, PSC2, PSC3, PSCA, PPC)

NPU Microcode

Firmware running on the Network Processing Unit (NPU).

Slave SCB

Firmware component that allows non-SMC cards to communicate with the SMC over the system control bus (SCB).

PSR, PSR2

Power, Status, and Reset firmware.

BIOS

Basic Input/Output System firmware.

DT FPGA, DT2 FPGA

Data Transport (DT) Field Programmable Gate Array (FPGA) firmware.

CPU 0 Type/Memory

Socket: 0, <processor type>, <processor speed>.

Socket: 1, <processor type>, <processor speed>.

Chipset: <components>.

CPU 0 DIMM-N0D0 P/N

Dual In-line Memory Module part number.

CPU 0 DIMM-N0D1 P/N

Dual In-line Memory Module part number.

CPU 0 DIMM-N1D0 P/N

Dual In-line Memory Module part number.

CPU 0 DIMM-N1D1 P/N

Dual In-line Memory Module part number.

CPU 1 Type/Memory

<processor type> <processor speed> <memory in MB>

CPU 0 CFE/Diags

Common Firmware Environment/Diagnostic firmware.

Line Cards (SPIO, RCC, FELC, GELC/GLC2, QGLC, XGLC, CLC/CLC2, OLC/OLC2)

Slave SCB

Firmware component that allows non-SMC cards to communicate with the SMC over the system control bus (SCB).

FPGA

Field-Programmable Gate Array firmware.

SFP Info (Port 1 or 2)

Information about the Small Form-factor Pluggable (SFP) transceivers includes:

Vendor Name, Vendor IEEE ID, P/N (part number), S/N (serial number, date.

show hardware card (ASR 5500)

Table 4. show hardware card Command Output Descriptions (ASR 5500)
Field Description

Common to All Card Types

Card <number>

Slot number of the specified card.

Card Type

Data Processing Card

Management & 20x10Gb I/O Card

Management v2 & 4x 100Gb I/O Card

System Status Card

Fabric & 2x200GB Storage Card

Description

Card type – DPC, DPC2, MIO, MIO2, SSC, FSC.

Starent Part Number

Legacy part number (xxx-xx-xxxx xx).

Cisco Part Number

Cisco part number.

CLEI Code

Common Language Equipment Identifier (CLEI) code.

UDI Serial Number

Unique Device Identifier (UDI) serial number (alphanumeric string).

UDI Product ID

UDI Product Identifier (PID) [alphanumeric string].

UDI Version ID

UDI version (alphanumeric string).

UDI Top Assem Num

UDI for top-level assembly.

Data Processing Card (DPC)

Daughter Card #3

Daughter card number.

Card Type

DPC CCK Daughter Card (crypto).

Description

DPC_CRYPTO_DC.

Starent Part Number

Legacy part number (xxx-xx-xxxx xx).

UDI Serial Number

UDI serial number (alphanumeric string).

Card Programmables

Indicates if the software on any of the programmable components on the card is not at the current revision.

"up to date" – all software is current

"out of date" – identifies one or more components do not have the most current software.

"experimental/unreleased" – one or more components have experimental or unreleased software.

BCF

Board Control FPGA firmware.

CAF

Control and Availability FPGA firmware.

CPU 0 Type/Memory

Socket 0: <processor type>, <processor speed>

Socket 1: <processor type>, <processor speed>

CPU 0 DIMM-N0C0D0 P/N

Dual In-line Memory Module part number.

CPU 0 DIMM-N0C1D0 P/N

Dual In-line Memory Module part number.

CPU 0 DIMM-N0C2D0 P/N

Dual In-line Memory Module part number.

CPU 0 DIMM-N1C0D0 P/N

Dual In-line Memory Module part number.

CPU 0 DIMM-N1C1D0 P/N

Dual In-line Memory Module part number.

CPU 0 DIMM-N1C2D0 P/N

Dual In-line Memory Module part number.

CPU 0 BIOS

Basic Input/Output System.

CPU 0 i82599

Intel 10GbE Controller firmware.

CPU 0 i82574

Intel Gigabit Ethernet Controller firmware.

CPU 0 CFE

Common Firmware Environment version.

CPU 1 Type/Memory

Socket 0: <processor type>, <processor speed>

Socket 1: <processor type>, <processor speed>

CPU 1 DIMM-N0C0D0 P/N

Dual In-line Memory Module part number.

CPU 1 DIMM-N0C1D1 P/N

Dual In-line Memory Module part number.

CPU 1 DIMM-N0C2D2 P/N

Dual In-line Memory Module part number.

CPU 1 DIMM-N1C0D0 P/N

Dual In-line Memory Module part number.

CPU 1 DIMM-N1C1D1 P/N

Dual In-line Memory Module part number.

CPU 1 DIMM-N1C1D1 P/N

Dual In-line Memory Module part number.

CPU 1 BIOS

Basic Input/Output System.

CPU 1 i82599

Intel 10 GbE Controller firmware.

CPU 1 i82574

Intel Gigabit Controller firmware.

CPU 1 CFE

Common Firmware Environment version.

Management Input/Output (MIO)

Daughter Card #<number>

Daughter card number.

   Card Type

MIO 10x10Gb Daughter Card.

MIO CCK Daughter Card (crypto).

   Description

MDC

MIO_CRYPTO_DC

   Starent Part Number

Legacy part number (xxx-xx-xxxx xx)

   Cisco Part Number

Cisco part number.

   UDI Serial Number

Unique Device Identifier (UDI) serial number [alphanumeric string].

Midplane:

Chassis EPROM information.

   Card Type

Midplane EPROM Card.

MAC Addresses

Media Access Controller hexadecimal starting address in format: xx-xx-xx-xx-xx-xx.

   MEC:

Midplane EEPROM Card.

      Description

MEC.

      Cisco Part Number

Cisco part number (nn-nnnnn-nn Ln).

      UDI Serial Number

Unique Device Identifier (UDI) serial number [alphanumeric string].

      UDI Product ID

UDI Product Identifier (PID) [alphanumeric string].

      UDI Version ID

UDI version (alphanumeric string).

   Midplane:

      Description

Midplane.

      Cisco Part Number

Cisco part number (nn-nnnnn-nn Ln).

      UDI Serial Number

UDI serial number (alphanumeric string).

   Chassis:

       Description

Chassis.

      Cisco Part Number

Cisco part number (nn-nnnnn-nn Ln).

      UDI Serial Number

UDI serial number (alphanumeric string).

      UDI Product ID

Cisco Product Identifier (PID) [alphanumeric string].

      UDI Version ID

UDI version (alphanumeric string).

      UDI Top Assem Num

UDI for top-level assembly.

Card Programmables

Indicates if the software on any of the programmable components on the card is not at the current revision.

"up to date" – all software is current

"out of date" – identifies one or more components do not have the most current software.

"experimental/unreleased" – one or more components have experimental or unreleased software.

SDHC Flash

Secure Digital High Capacity on-board flash memory (/flash drive).

   Type

Disk capacity in Mbytes.

   Model

Generic-UltraFastMedia.

USB 1

Status of front panel USB port, for example. "Not Present".

SFP+ Module On Port <number>:

Information on the SFP+ transceiver in the specified port (10 through 29).

   Transceiver Info

SFP+ transceiver type.

   Vendor Info

Vendor Name and Vendor IEEE ID.

   Part Info

Cisco PID and serial number.

System Status Card (SSC)

Card Programmables

Indicates if the software on any of the programmable components on the card is not at the current revision.

"up to date" – all software is current

"out of date" – identifies one or more components do not have the most current software.

"experimental/unreleased" – one or more components have experimental or unreleased software.

BCF

Board Control FPGA firmware.

Fabric and Storage Card (FSC)

Card Programmables

Indicates if the software on any of the programmable components on the card is not at the current revision.

"up to date" – all software is current

"out of date" – identifies one or more components do not have the most current software.

"experimental/unreleased" – one or more components have experimental or unreleased software.

BCF

Board Control FPGA firmware.

show hardware inventory (ASR 5x00)

Table 5. show hardware inventory Command Output Descriptions
Field Description

Slot

Slot number of the specified card.

Type

Descriptor of the card in the specified slot.

Part Number

Starent or Cisco part number.

Product ID / Version ID

Cisco PID and version identifier.

Serial Number

Serial number of the card.

CLEI code

Common Language Equipment Identifier (CLEI) code.

Fan Tray (ASR 5500 only)

Lower Rear

Lower Front

Upper Rear

Upper Front

show hardware version (ASR 5000)

Table 6. show hardware version Command Output Descriptions (ASR 5000)
Field Description

Slot

Slot number of the specified card.

Type

Descriptor of the card in the specified slot.

Packet Processing Card

SSCB

Slave Serial Control Bus (SSCB) firmware.

PSR, PSR2

Power, Status, and Reset firmware.

BIOS A

Basic Input/Output System A.

BIOS B

Basic Input/Output System B.

DT, DT2

Data Transport (DT) FPGA firmware.

System Management Card

SRM

Status, Reset, and Monitoring (SRM) firmware.

BIOS A

Basic Input/Output System A.

BIOS B

Basic Input/Output System B.

On-Card

Version of the firmware that is on the boot flash for the component.

CIF-FPGA Running

Chassis Information (CIF) FPGA firmware that is currently operational.

Line Cards

SSCB

Slave Serial Control Bus (SSCB) firmware.

FPGA

Field Programmable Gate Array.

On-Card

Version of the firmware that is on the boot flash for the component.

WPOS Running

WinPath Operational Software

Diagnostic Revisions

On-Card

Version of the firmware that is on the boot flash for the component.

CPU 0 Running

Firmware that is currently operational on this CPU.

Fan Tray Controller Version

Upper Fan Tray

UFT controller firmware.

Lower Fan Tray

LFT controller firmware.

show hardware version (ASR 5500)

Table 7. show hardware version Command Output Descriptions (ASR 5500)
Field Description

Slot

Slot number of the specified card.

Type

Descriptor of the card in the specified slot – DPC, DPC2, MIO, MIO2, SSC, FSC.

BCF

Board Control FPGA firmware.

CAF

Control and Availability FPGA firmware.

CAF Rcry

CAF Recovery.

DCF A

Daughter Card FPGA A firmware.

DCF B

Daughter Card FPGA B firmware.

CPU

CPU number.

BIOS A

Basic Input/Output System A.

BIOS B

Basic Input/Output System B.

82599 A

Intel 10GbE Controller firmware.

82574 A

Intel Gigabit Ethernet Controller firmware.

PLX8618

PCIe Switch PROM.

N9485 A

Serial Attached SCSI Controller A, SPI (SCSI Parallel interface) Flash.

N9485 B

Serial Attached SCSI Controller B, SPI Flash.

CFE Flsh

Common Firmware Environment on /flash.

Fan Tray Controller Version

Upper Fan Tray

UFT controller firmware (front and rear).

Lower Fan Tray

LFT controller firmware (front and rear).

show hardware version (VPC-DI)

Table 8. show hardware version (VPC-DI) Command Output Descriptions (VPC-DI)
Field Description

Slot

Slot number of the specified card.

Type

Descriptor of the card in the specified slot – CFC or SFC.

CFE Flash

Version number of Common Firmware Environment.